product line - torrent engineering & equipment · product line ge motors. ... gas turbine...
TRANSCRIPT
Product Line
GEMotors
EPAct EfficientValue Line Family of Products
Open Drip Proof1-400HP200, 230/460, 460, 575 VoltGEGARD180077 Insulation SystemInverter CapableCast Iron Frame & Endsheilds1.15 S.F.F-1 to F-2 modifiable
Totally Enclosed Fan Cooled¾ - 150HP200, 230/460, 460, 575 VoltGEGARD180077 Insulation SystemInverter CapableCast Iron Frame & Endsheilds 1.15 S.F.F-1 to F-2 modifiableC-Face or Footmount
Totally Enclosed Fan CooledSevere Duty¾ - 250HP230/460, 460, 575 voltGEGARD180077 Insulation Sys.Inverter CapableFull Cast Iron Construction1.15 S.F.F-1 to F-2 modifiableShaft Slinger
Totally Enclosed Fan CooledExplosion Proof1-200HP230/460 VoltFull Cast Iron ConstructionBrass Flinger on both endsNon-Sparking fanOversized Conduit Box
NEMA Premium7 Efficient
E$P Open Drip Proof1-300HP230/460, 575 voltGEGARD180077 Insulation SystemInverter CapableCast Iron Frame & Endsheilds1.15 S.F.
X$D Ultra77 Extra Severe DutyTotally Enclosed Fan Cooled1-300HP230/460, 460, 575 voltFull Cast Iron Construction 1.15 S.F.GEGARD200077 Insulation SystemSix Star Bearing™ System with 0.04 ipsRecessed Steel Reinforced V-Ring Slinger
X$D Ultra77 841 Extra Severe DutyTotally Enclosed Fan Cooled1-250HP460, 575 voltFull Cast Iron ConstructionMeets or exceeds IEEE 841 StandardsGEGARD200077 Insulation SystemSix Star Bearing™ System with 0.04 ipsD.E. and O.D.E. Inpro Seal™
Direct Current Motors
Permanent Magnet DC¼ - 3HP90 or 180 VDC FieldC-Face w/bolt on feetProvision for tachometerDrive CapableCont. Torque to 5% base speed
with free wheeling diode
Kinamatic II1-500HP240, 500 VDC Armature150/300 VDC FieldTIG Welded Copper to Copper
CommutatorsDPFG, DPFG-BV, TE
CD6000-CD6900500-2000HP240, 500 VDC Armature150/300 VDC FieldSturdy TREC7 Main and CommutatingField Coils are StandardTIG Welded Copper to Copper
CommutatorsDPG, DPG-BV, TEFC
Application Specific
X$D Ultra77 661 Extra Severe DutyTotally Enclosed Fan CooledHeat Exchanger5-75 HP380, 460 voltMeets API 661 & IEEE 841 StandardsGEGARD200077 Insulation SystemRoller Bearing L10 Life: 40,000 hrsD.E. and O.D.E. Inpro Seal™IP-55 Protection4 pt Cast-in-lifting Lugs for
Safe and Easy Vertical Lifting
X$D Ultra77 Extra Severe DutyTotally Enclosed Fan CooledHigh Torque - NEMA Design “C”40-300 HP230/460, 460, 575 voltDesign “C” 1.15 S.F.GEGARD200077 Insulation SystemSix Star Bearing™ System with 0.04 ipsRecessed Steel Reinforced V-Ring Slinger
Vertical MotorsWeather-Protected (WPI)5-300 HP230/460, 460 Volt (Part Winding Start)GEGARD180077 Insulation SystemCast Iron Frame & EndshieldStamp Steel Top HatBall RatchetHigh ThrustInverter Capable
Custom Vertical1-800 HP230, 460, 2300 or 4160 VoltCast Iron FrameWPI, WPII, TEFCSolid or Hollow Shaft DesignsNormal, High or Extra-High Thrust DesignsStandard or Energy Efficient Electrical Designs
MD800 Mill Duty5-500 HPMeets AISE StandardSplit Frame DesignDouble Tapered ShaftClass H InsulationTRECTM Coils
Electric VehicleSystems2-30 HP36 to 80 VDCPartial motor design
for OEM replacement 19T or 10T female shaft extensionTraction, Hydraulic Pump
and Power Steering
Adjustable Speed Motor A$D1.5-300 HP230/460, 460, 575 voltTotally EnclosedGEGARD200077 Insulation SystemInfinite:1 Constant Torque Speed Range3 N.C. ThermostatUL and CSA recognizedProvision to Install Encoder
Commercial Refrigeration81 mm & 92 mm2-90 watts100-1650 RPMUL and CSA listedStandard and High EfficientShaded Pole or Permanent
Split CapacitorThreaded Shaft
Totally Enclosed Fan Cooled (IP54)High Speed3-150 HPC-Face Footed230/460 Volt, 60 Hz at 1.15 SF200/400 Volt, 50 Hz at 1.15 SF
and Derated to next lowest HPGEGARD180077 Insulation SystemCE MarkedQty 2 N.C. Thermostat
Above NEMA
500 FrameLow & Medium Voltage250-800HP460,2300, 4160, 6600 VoltODP, WPII, TEFCVertical or Horizontal ConfigurationCustom Polyseal® Insulation available
Wound Rotor Motors500-15,000 HP (11,000 kW)Up to 6600 VoltsFabricated Steel Frame ConstructionNEMA & IEC DesignsWPI, WPII, TEAAC, TEWAC
Large DC MotorsUp to 12,000 HP (8,952 kW)Class F or H insulationSplit magnet frame for easy maintenanceHigh thrust & torque capabilitiesMarine Generation and Propulsion,Mining & Metal applications
450-7000 Frame HorizontalLow & Medium Voltage Induction350-2,000 HP (250-1,400 kW)Up to 6600 Volts2 to 10 PoleNEMA & IEC DesignsAPI 541, 547TEFC
8200-8900 Frame HorizontalMedium & High Voltage Induction500-15,000 HP (11,000 kW)Up to 13800 VoltsFabricated Steel Frame ConstructionNEMA & IEC DesignsAPI 541, 547WPI, WPII, TEAAC, TEWAC
Large AC Synchronous Motors1000-100,000 HP (75,000 kW)Up to 15,000 VoltsSpecifications & Standards,
NEMA, CSA, IEEE, IEC, API 546Solid Salient Rotor Design for 4 & 6 PoleCustomized design available for various
applicationsProven design and manufacturing
techniques
8200-8900 Frame VerticalMedium & High Voltage Induction500-12,500 HP (9,000 kW)Up to 13800 VoltsFabricated Steel Frame ConstructionNEMA & IEC DesignsAPI 541Normal or High Thrust DesignsWPI, WPII, TEAAC, TEWAC
GeneratorsAC Design Up to 75,000 kVAUp to 13,800 VoltsVertical and horizontal configurationsSpecifications & Standards, NEMA,
CSA, IEEE, IEC, API4 & 6 pole for Steam and
Gas Turbine applications8 pole and above for small hydro apps.All types of enclosures are available
Low Voltage Drives
AF-600 GP General Purpose Drive1/3 - 50 HP, 230 Volt1/2 - 1,200 HP, 460 Volt1- 1,350 HP, 575/690 VoltIdeally suited for constant torque and variable
torque applicationsNEMA 1, 4, & 12 Stand Alone drive optionsBuilt-in Modbus RTUQuick Menu, Closed Loop Vector with built-in
encoder feedback and On-Board Manual
AF-60 LP Micro Drive1/4 - 10 HP230 & 460 VoltCompact with built-in brake chopper, RFI Filterand removable keypad with Quick Menu, H-O-A,and single turn potentiometerIdeal for pumps, fans, mixers, and conveyors
Medium Voltage Drives
Dura-Bilt 5i MV400-5,000 HP298-3,730 kWH2000-2400, 3000-3400, 4000-4200 VoltsCompact DesignHeat Pipe Air-Cooled InverterIEEE 519 CompliantSensorless Vector ControlCopper Wound Transformer Included as Standard5 Year Warranty
AF-600 FP Fan/Pump Drive1 - 60 HP, 230 Volt1 - 1,350 HP, 460 & 575 VoltIdeally suited for HVAC, pumps, blowers, and compressorsNEMA 1, 12 Stand Alone drive optionsBuilt-in Modbus RTU, Metasys N2, & Apogee FLN
P1 networks. Options for BACnet, LonWorks, DeviceNet, and Profibus DP
Quick Menu, Fan/Pump Macros, 4 Auto-Tune PID Controllers, Cascade Pump Controller, Real Time
Clock, Energy Savings Mode, and On-Board Manual.
imagination at workg
GE Motors
USAFort Wayne, IN 46802
800 541 7191www.gemotors.com
82007 General Electric Company All rights reserved. GE, g, X$D Ultra, GEGARD1800, GEGARD2000, and the Six StarBearing System are trademarks of General Electric Company.
NEMA Premium is a trademark of NEMA.
DEA-M0377C 1007
Genuine Parts
GEGARD Insulation SystemGuaranteed Ultimate Performance on Inverter Power
GE Genuine Parts were designed for your GE motors. They will always fit perfectly saving you time and effort.
“Coils from other suppliers almost always require somE form-ing and bending which can damage the coil insulation andincrease labor time. GE armature coil kits include clips andsoldering blocks. These fit perfectly and are two less itemswe have to chase down when we rewind an armature…”
Robert N. MilesGE Energy Services
Superior Product Quality
• Genuine GE parts built to original designs using latest materials and manufacturing processes.
• A full complement of spare parts are available for the entire range of GE motors.
Exact Fit and Specification
• Average installation time is reduced compared to competitor parts in GE motors.
World Class Service
• Our Dedicated Renewal Parts Team is fully integrated with technology and manufacturing.
• Identification of common spare parts is based simply on machine model or serial number
Spare Parts Program
• Customers minimize downtime with an adequate spare parts inventory plan for their GE motors.
CoilsArmatureFieldStatorAmmortisseurSynchronous Rotor PolesEqualizer
Commutators/CollectorsReplacement CommutatorSlip Ring Assemblies
Brush AssemblyBrushesSpringsBrushholders
BearingsSleeve BearingsOil Rings
ExcitersRotor & Stators
AccessoriesAir FiltersMolded Equalizer TraysSpeed Limit SwitchesHeatersThermostatsThyristorsConverter AssembliesOil GuagesFansBlower Assembly or Wheel
GEGARD1800TM
This system exceeds NEMA MG1-31(which is 3.1 times the nameplate volt-age) for motors operating on inverters.The insulation system is comprised ofclass F materials and the varnish is non-hygroscopic, anti-fungus. The varnishis either applied via a Dip and Bake, orVacuum Pressure Impregnation (VPI)process. The combination of materialsand processes provides a minimumCorona Inception Voltage (CIV) up to1800 volts peak with a rise time of 0.1 microseconds.
GEGARD2000TM
This system exceeds NEMA MG1-31 (whichis 3.1 times the nameplate voltage) formotors operating on inverters. The insulationsystem is comprised of class H materials andthe varnish is non-hygroscopic, anti-fungus.The varnish is applied via a Trickle Treatprocess while a 60 Hz current is passedthrough the windings. This causes thevarnish to flow through the winding resultingin improved penetration into the stator slotsand an increase in varnish build. The currentalso cures the winding from the inside out,rather than oven baking. The combinationof materials and processes provides aminimum Corona Inception Voltage (CIV)up to 2000 volts peak with a rise time of 0.1 microseconds.