Russia Power 2006 14-16 March 2006 Moscow, Russia ID Number: 61 Power Diagnostics ® Service for steam turbines and generators Vanessa Bauch and Michael Killich Siemens Power Generation Germany 1/20 © Siemens AG 2006. All rights reserved.

Upload: others

Post on 09-Feb-2022

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 2: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 3: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 4: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 5: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 6: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 7: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 8: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 9: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 10: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 11: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 12: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 13: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 14: Power Diagnostics® Service for Steam Turbines and - Siemens

Russia Power 2006 14-16 March 2006 Moscow, Russia ID Number: 61

since the scope did not include the generator. Power Diagnostics® Services were significant

in preventing a forced outage.

The turbine-generator set has one high pressure and two low pressure turbines and a water

cooled generator. The turbine and generator side at the low pressure turbine, the turbine and

exciter side at the generator, the exciter bearing and the shaft pump were examined by

vibration test points (see figure 8).

System configuration

Absolute bearing vibrations (mm/s)

Relative shaft vibrations (µm)

Figure 8: System configuration and vibration test points

Examination of the vibration behavior between 10th February – 10th March showed changes

in the vibration behavior as from 21. February (see figure 9). The measurement values were

still under the limit values so the operator was not really alarmed. Concerning vibration

issues changes are always indications, even if limit values were not exceeded therefore the

situation was seen as a task force issue.

In order to get a detailed view of the vibrations the summarized values of the amplitudes as

well as the vibration vectors were examined. The vibration vectors showed high changes of

the vibration level - about three times higher. The high variations of the vibration level

indicate a generator vibration problem (see figure 10).

14/20 © Siemens AG 2006. All rights reserved.

Page 15: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 16: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 17: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 18: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 19: Power Diagnostics® Service for Steam Turbines and - Siemens
Page 20: Power Diagnostics® Service for Steam Turbines and - Siemens