plan c plan b - transport scotland · plan b plan b plan a plan a forres springfield broom of moy...
TRANSCRIPT
BRODIE
DYKE
MUNDOLE
HARDMUIR
PL
AN
B
PLA
N B
PL
AN
A
PL
AN
A
FORRES
SPRINGFIELD
BROOM OF MOY
INVERERNE
MAINS OF
BURGIE
SGN GAS
DISTRIBUTION
STATION
PL
AN
B
PL
AN
C
PL
AN
B
PL
AN
C
PL
AN
B
PL
AN
B
PL
AN
A
PL
AN
A
Notes
Original Size
Client
Date Date Date Date
Drawing Number Project Ref. No.
Revision
Scale Designed Drawn Checked Approved
TS PIN | Originator | Volume I Location | Type | Role | Number
Drawing Title
Project Title
Drawing Status Suitability
Key to symbols
Rev Date Amendment Details Orig Chk'd App'd
This drawing should not be relied on or used in circumstances other than those for which it was originally prepared and for which Mott MacDonald Sweco JV was commissioned. This drawing has been prepared for the titled project or named part thereof and should not be relied upon or used for any other project without an independent check being carried out as to its suitability and prior written authority of Mott MacDonald Sweco JV
being obtained.
A2Approved as Stage Complete
A96 DUALLING HARDMUIR TO FOCHABERS
FIGURE 2.14 EXISTING CONDITIONS
- UTILITIES
SHEET 1 OF 3
As Shown O'Carroll, Barry
14/08/18
O'Carroll, Barry
14/08/18
Lyng, Ronan
14/08/18
Wallace, Steve
14/08/18
MMS GEN 20000 DR D 00004
A96PHF
A96PHF
pw:\\CSPWInt.grontmij.net:PW_UK Production\Documents\Projects\Transportation\A96PHF - A96 Hardmuir to Fochabers\General\General\Drgs & Models - 2D drawing\A96PHF-MMS-GEN-20000-DR-D-00004
A1
C01
C01
P02
P01
27/11/18
27/10/18
22/10/18
DD
AR
AR
BP
BP
BP
RL
RL
RL
Approved as Stage Complete
For Stage Approval
For Review and Comment
SCALE 1 : 12500
m0500m 500
Reproduced by permission of Ordnance Survey on behalf of HMSO. © Crown Copyright and database right 2018. All rights reserved. Ordnance Survey License number 100046668.
OVERHEAD BT CABLE
UNDERGROUND BT CABLE
INFERRED BT CABLE
VODAFONE (THUS) CABLE
LOW PRESSURE GAS MAIN
MEDIUM PRESSURE GAS MAIN
INTERMEDIATE PRESSURE GAS MAIN
HIGH PRESSURE GAS MAIN
COMBINED SEWER OUTFALL
TRUNK WATER MAIN
WATER MAIN
SEWER MAIN
UNKNOWN PIPELINE
PFI SEWER
OTHER MAIN
SSE LINE
33kV LINE
132kV OVERHEAD LINES
COMMUNICATION MASTS
AREAS NOT INCLUDED WITHIN UTILITY SEARCH
FORRES
FOCHABERS
ELGIN
PLAN A - SCALE 1 : 12,500
PLAN B - SCALE 1 : 12,500
A
B
PL
AN
D
PLA
N D
TOREDUFF
CLOVES
ALVES
COLTFIELD
MOSSTOWIE
ARDGYE
PLA
N C
PL
AN
C
P
L
A
N
C
P
L
A
N
C
P
L
A
N
B
P
L
A
N
B
PL
AN
D
PLA
N D
BISHOPMILL
PALMERSCROSS
PITTENDREICH
ELGIN
NEW ELGIN
MOSS OF
BARMUCKITY
PLA
N C
PLA
N C
P
L
A
N
E
P
L
A
N
E
P
L
A
N
D
P
L
A
N
D
Notes
Original Size
Client
Date Date Date Date
Drawing Number Project Ref. No.
Revision
Scale Designed Drawn Checked Approved
TS PIN | Originator | Volume I Location | Type | Role | Number
Drawing Title
Project Title
Drawing Status Suitability
Key to symbols
Rev Date Amendment Details Orig Chk'd App'd
This drawing should not be relied on or used in circumstances other than those for which it was originally prepared and for which Mott MacDonald Sweco JV was commissioned. This drawing has been prepared for the titled project or named part thereof and should not be relied upon or used for any other project without an independent check being carried out as to its suitability and prior written authority of Mott MacDonald Sweco JV
being obtained.
A2Approved as Stage Complete
A96 DUALLING HARDMUIR TO FOCHABERS
FIGURE 2.15 EXISTING CONDITIONS
- UTILITIES
SHEET 2 OF 3
As Shown O'Carroll, Barry
14/08/18
O'Carroll, Barry
14/08/18
Lyng, Ronan
14/08/18
Wallace, Steve
14/08/18
MMS GEN 20000 DR D 00005
A96PHF
A96PHF
pw:\\CSPWInt.grontmij.net:PW_UK Production\Documents\Projects\Transportation\A96PHF - A96 Hardmuir to Fochabers\General\General\Drgs & Models - 2D drawing\A96PHF-MMS-GEN-20000-DR-D-00005
A1
C01
C01
P02
P01
27/11/18
27/10/18
22/10/18
DD
CB
CB
BP
BP
BP
RL
RL
RL
Approved as Stage Complete
For Stage Approval
For Review and Comment
SCALE 1 : 12500
m0500m 500
Reproduced by permission of Ordnance Survey on behalf of HMSO. © Crown Copyright and database right 2018. All rights reserved. Ordnance Survey License number 100046668.
OVERHEAD BT CABLE
UNDERGROUND BT CABLE
INFERRED BT CABLE
VODAFONE (THUS) CABLE
LOW PRESSURE GAS MAIN
MEDIUM PRESSURE GAS MAIN
INTERMEDIATE PRESSURE GAS MAIN
HIGH PRESSURE GAS MAIN
COMBINED SEWER OUTFALL
TRUNK WATER MAIN
WATER MAIN
SEWER MAIN
UNKNOWN PIPELINE
PFI SEWER
OTHER MAIN
SSE LINE
33kV LINE
132kV OVERHEAD LINES
COMMUNICATION MASTS
FORRES
FOCHABERS
ELGIN
PLAN C - SCALE 1 : 12,500
PLAN D - SCALE 1 : 12,500
C
D
AREAS NOT INCLUDED WITHIN UTILITY SEARCH
DIPPLE
FOCHABERS
ORDIEQUISH
P
L
A
N
F
P
L
A
N
F
P
L
A
N
E
P
L
A
N
E
LHANBRYDE
MOSSTODLOCH
PL
AN
E
PL
AN
E
PL
AN
D
PL
AN
D
P
L
A
N
F
P
L
A
N
F
P
L
A
N
E
P
L
A
N
E
Notes
Original Size
Client
Date Date Date Date
Drawing Number Project Ref. No.
Revision
Scale Designed Drawn Checked Approved
TS PIN | Originator | Volume I Location | Type | Role | Number
Drawing Title
Project Title
Drawing Status Suitability
Key to symbols
Rev Date Amendment Details Orig Chk'd App'd
This drawing should not be relied on or used in circumstances other than those for which it was originally prepared and for which Mott MacDonald Sweco JV was commissioned. This drawing has been prepared for the titled project or named part thereof and should not be relied upon or used for any other project without an independent check being carried out as to its suitability and prior written authority of Mott MacDonald Sweco JV
being obtained.
A2Approved as Stage Complete
A96 DUALLING HARDMUIR TO FOCHABERS
FIGURE 2.16 EXISTING CONDITIONS
- UTILITIES
SHEET 3 OF 3
As Shown O'Carroll, Barry
14/08/18
O'Carroll, Barry
14/08/18
Lyng, Ronan
14/08/18
Wallace, Carol
14/08/18
MMS GEN 20000 DR D 00006
A96PHF
A96PHF
pw:\\CSPWInt.grontmij.net:PW_UK Production\Documents\Projects\Transportation\A96PHF - A96 Hardmuir to Fochabers\General\General\Drgs & Models - 2D drawing\A96PHF-MMS-GEN-20000-DR-D-00006
A1
C01
C01
P02
P01
27/11/18
27/10/18
22/10/18
DD
AR
AR
BP
BP
BP
RL
RL
RL
Approved as Stage Complete
For Stage Approval
For Review and Comment
SCALE 1 : 12500
m0500m 500
Reproduced by permission of Ordnance Survey on behalf of HMSO. © Crown Copyright and database right 2018. All rights reserved. Ordnance Survey License number 100046668.
OVERHEAD BT CABLE
UNDERGROUND BT CABLE
INFERRED BT CABLE
VODAFONE (THUS) CABLE
LOW PRESSURE GAS MAIN
MEDIUM PRESSURE GAS MAIN
INTERMEDIATE PRESSURE GAS MAIN
HIGH PRESSURE GAS MAIN
COMBINED SEWER OUTFALL
TRUNK WATER MAIN
WATER MAIN
SEWER MAIN
UNKNOWN PIPELINE
PFI SEWER
OTHER MAIN
SSE LINE
33kV LINE
132kV OVERHEAD LINES
COMMUNICATION MASTS
FORRES
FOCHABERS
ELGIN
PLAN E - SCALE 1 : 12,500
PLAN F - SCALE 1 : 12,500
E
F
AREAS NOT INCLUDED WITHIN UTILITY SEARCH