overview - la- · pdf filegsm/umts/hspa +/ gps/glonass ... •max total current 6a...

17
Overview 11.5.2016 1

Upload: lydiep

Post on 15-Mar-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

Overview

11.5.20161

11.5.20162

• Powerful 32 bit processor

• High calculation power

• Can be used as a calculating unit and/or as

remote access unit

• CODESYS 3.5 programmable

• Displays

• Bright and colorful panel

• High brightness and contrast

• Wide viewing angle

6100 Remote Access Unit

6107Display

6112Display

Processor 32 bit / 792 MHz 32 bit / 792 MHz 32 bit / 792 MHz

Memory * Flash 4-16 GB RAM 1024 MB NV memory 512 kB

Flash 4-16 GB RAM 1024 MB NV memory 512 kB

Flash 4-16 GB RAM 1024 MB NV memory 512 kB

OS Linux Linux Linux

Protection Class IP66 IP66 IP66

Connectors 1 x AMP231 x mini-B USB (M12) 1 x M12 0-2 x SMA antenna connector

1 x AMP231 x mini-B USB (M12) 2-4 x M12 0-2 x SMA antenna connector

1 x AMP231 x mini-B USB (M12) 2 x M12 2 x SMA antenna connector

11.5.20163

*Memory sizes are hardware specific

6100Remote Access Unit

6107Display

6112Display

CAN 2.0 B 2 2 2

RS-232 1 1 1

USB 2 2 2

Ethernet (10/100 Mbps) 2 0 – 2 2

GSM/UMTS/HSPA +/GPS/GLONASS

Yes Yes * Yes *

Camera * No 2 * 2 *

Mini-SIM Yes Yes * Yes *

Wifi/BT * Future releases Future releases Future releases

Ext. Display * Future releases Future releases Future releases

11.5.20164

*Optional

11.5.2016 LUOTTAMUKSELLINEN5

11.5.2016 LUOTTAMUKSELLINEN6

11.5.2016 LUOTTAMUKSELLINEN7

6100Remote Access Unit

6107Display

6112Display

Operating Temperature -30... +70 ° C -30... +70 ° C-30... +55 °C with

2G/3G/GPS option

-30... +70 °C

Operating Voltage 12/24 VDC,Full Range 8,4 ... 36 VDC

12/24 VDC,Full Range 8,4 ... 36 VDC

12/24 VDC,Full range 9,2 ... 36 VDC

Undervoltage Reset ≤ 8 VDC ≤ 8 VDC ≤ 8,5 VDC

Power Consumption 90 W (+24 VDC, full load)40 W (+24 VDC, typical)

100 W (+24 VDC, full load)50 W (+24 VDC, typical)

-

Display No Yes Yes

Speaker / Buzzer No Yes (Speaker) Yes (Buzzer)

RTC (Real-Time Clock) Yes Yes Yes

11.5.20168

6107Display

6112Display

Display Size 7” TFT color LCD

12,1”TFT color LCD

Touch Screen Resistive (GFG) Capacitive (PCAP)

Resolution WVGA 800 x 480 (5:3) XGA 1024x 768 (4:3)

Colors High color, 65 536 colors (16 bits) High color, 65 536 colors (16 bits)

Backlight LED, lifetime 70 000 hours at 25 °C LED, lifetime 50 000 hours at 25 °C

Brightness 800 cd/m2 600 cd/m2

Brightness Control Manual/automatic LED backlight control Manual LED backlight control

Contrast 600:1 700:1

Viewing angle 170° (super wide) 160 ° vertical140 ° horizontal

11.5.20169

• 2 x CAN 2.0 B

• Supported bit rates

• 50, 125, 250, 500, 800 and 1000 kbit/s

• Both 11 and 29 bit message IDs supported

• RTR (Remote Transmission Request)

supported

• User programmable. Epec provides

implementations for CANopen and SAE

J1939 protocols.

11.5.201610

• Operating voltage range

• 8,4…36 VDC (6100, 6107)

• 9,2…36 VDC (6112)

• Undervoltage threshold level

• ≤ 8 VDC (6100, 6107)

• ≤ 8,5 VDC (6112)

• Max total current 6A

• GND current sum max 6A

11.5.201611

• Overvoltage protection

• Supply voltage > 36,8V, the display unit

shuts down

• Starts again when voltage drops under 36,8V

• Withstands continuous voltage up to 70V

• Withstands transient voltage peaks up to 123V

without damage to the display

• Load dump protection according to ISO7636-

2: 2004 pulse 5, Us=+123 V

11.5.201612

• Outputs (PWM/DO/DI) have a switching

element called smart FET

• It has integrated features to protect itself

and also the external pin, wiring and

actuator

• It is recommended to use

DigitalOutputDiagnostics library function

blocks for additional protection when

output is used as DO.

11.5.201613

• A switch will disconnect the

measurement circuit if an

overvoltage event is

detected

• Overvoltage protection

mode is indicated with a

dedicated signal

• The protection mode is

active as long as the

overvoltage persists or it is

momentarily bypassed via

application

11.5.201614

11.5.201615

Inputs 2 DI Pull-down resistor to ground

1 AI - Mode selection by application (0..5 V / 0..22 mA)- Pull-up selection by application

Outputs 2 DO/DI - Sourcing- Output state monitoring feature (DI)- Current output 1A/pin

1 REF out +5V / 100mA

• Supply voltage

• Internal temperature

• Reference voltage overload and

overvoltage

• Application cycle time

• CAN network status

11.5.201616

• CODESYS 3.5

• MultiTool

• 6107 supported since MT 3.3

• 6100 and 6112 supported since MT 4.2

• PLCopen libraries

• CANopen, J1939, NetworkManager

• Events, SWDownload, Parameters

• CSVParser, ADConversion, AI

• Serial, Modem, USB, Multimedia, MRAM

11.5.201617