outdoor mmds transmitter - unique broadband...
TRANSCRIPT
Outdoor MMDS TransmitterUnique Broadband Systems Ltd.
The transmitter is housed in a corrosion resistant, weather-proof NEMA-style cabinet for outdoor pole mounting and it is designed with maximum reliability and versatility in mind. The hinged front panel provides easy access to internally mounted components for control and maintenance.
The temperature inside the enclosure is thermostatically con-trolled. The outdoor MMDS transmitters are available in two AC power options: 220V – 50 Hz and 115V – 60 Hz.
Extended bandwidth and alternate frequency configurations are available. UBS can also supply monitoring software, control software, and hardware packages, all customized to meet spe-cific requirements.
The 50 Watt and 100 Watt outdoor broadband transmitters are intended for use in Multi-Channel Multi-Point Distribution Sys-tem (MMDS). They are capable of transmitting between one and thirty-one 6 MHz analog or digital channels in the 2.5 GHz to 2.7 GHz frequency range.
These broadband transmitters can provide cost-effective, omni-directional or sectorized coverage for small to medium size markets. The transmitters are compatible with all current modulation schemes and are transparent to all popular encod-ing systems. The transmitted signals can be received using standard customer premises downconverter and decoding equipment.
The transmitters feature RF muting when the input IF signal is below the preset threshold. Thermal shutdown and overpower shutdown are automatic protection features incorporated in the Transmitter. The transmitter parameters can be controlled directly or remotely through an external monitoring unit.
Product Description
Product Features
•Weatherproofoutdoorthermostaticallycontrolleddesign
•Full2500MHzto2700MHzcapability
•Automaticoutputlevelcontrol
•222MHzto422MHzIFinput
•Localoroptionalremotemonitoringandcontrol
•Compatiblewithallcurrentanaloganddigitalmodulationschemes
•Optionaltransmitterredundancyconfigurations
Models: PmP-Tx-50-2527-O-B-1PmP-Tx-50-2527-O-B-2
PmP-Tx-100-2527-O-B-1PmP-Tx-100-2527-O-B-2
VER 1.3 August 24, 2009
Wireless Broadband and Broadcasting Solutions
Outdoor MMDS TransmitterModels: PmP-Tx-50-2527-O-B-1 PmP-Tx-100-2527-O-B-1 PmP-Tx-50-2527-O-B-2 PmP-Tx-100-2527-O-B-2 Unique Broadband Systems Ltd.
Product Specifications (specifications are subject to change without notice)
Parameters Tx-50 / Tx-100Output Power at 1 dB Gain Compres-sion Point, single CW tone
50 Watts / 100 Watts
Output Frequency 2.5 GHz - 2.7 GHz
IF Input Level, ALC on -20 dBm to -10 dBm
IF Input Frequency 222 MHz - 422 MHz
Frequency Stability ≤ ±500 Hz
SSB Phase Noise ≤ -110 dBc/ Hz @ 10 kHz offset
In-band Spurious Products ≤ -60 dBc
Harmonics ≤ -60 dBc
Hum and Noise ≤ -60 dBc
Group Delay ≤ ±10 ns
Analog PerformancePeak Sync Output Power, single channel
25 Watts / 50 Watts
Composite RF Output Power, CTB –55 dBc
2.5 Watts / 5 Watts
Signal to Noise Ratio, in 6 MHz chan-nel
> 70 dB
Gain Flatness, in 200 MHz ±0.5 dB
Noise Figure ≤ 10 dB
Digital PerformanceDigital Average Output Power 5 Watts / 10 Watts
Spectral Regrowth at channel edge < -40 dB
Frequency Response, in 6 MHz chan-nel
≤ ±0.2 dB
RF Output Power stability, ALC on ≤ ±0.3 dB
Modulation Mode QPSK, 64/256 QAM, COFDM, AM, FM
Digital ModulationError Vector Magnitude (EVM) ≤ 2%
Signal to Noise ≥ 40 dB
Magnitude Linearity (AM-AM conver-sion)
≤ ±0.125 dB
Phase Linearity (AM-PM conversion) ≤ ±0.75°
ConnectorsIF Input Connector F-type (female), 75 ohm
IF Monitoring Connector F-type (female), 75 ohmLevel: Typ. 25 dB below the IF input level
RF Output Connector N-type (female), 50 ohm
RF Monitoring Connector N-type (female), 50 ohmLevel: Typ. 40 dB below the RF output level
Monitor Connector(optional) 26 pin connector, for optional indoor unit
VER 1.3 August 24, 2009
Wireless Broadband and Broadcasting Solutions
Power SupplyVoltage 115 VAC or 220 VAC
Frequency 60 Hz or 50 Hz
Power Consumption 500 VA / 800 VA
MechanicalDimensions 660 x 510 x 280 mm
(26” x 20” x 11”)
EnvironmentalOperating Temperature -40°C to +40°C (-40°F to +104°F)
Relative Humidity 100%
Cooling Natural convection
Wireless Broadband and Broadcasting Solutions
Unique Broadband Systems Ltd.
Part Number Configuration
DPA
BandYL – L-BandYS – S-BandYC – C-BandYX – X-BandKU – Ku-BandKA – Ka-Band
Output PowerL-Band
0250W,0500WS-Band
0150W, 0300WC-Band
0010W, 0020W,0040W,0080W,0100W,0150W,0200W,0250W,0300W,0325W,0400W,0650W,0800W
X-Band0275W, 0550W
Ku-Band0060W,0080W,0100W,0150W,0200W,0300W,0400W,0800W,
Ka-BandTWTA, UP TO
1.5KWAVAILABLE
PLEASE CALLFOR INQUIRY
FOR HIGHPOWER 1KWAND ABOVE
PLEASECONTACT OUR
SALESDEPARTMENT
Sub Band
L-BandA (1.0-2.0 GHz)B (1.5-3.0 GHz)C (1.0- 2.5 GHz)
S-BandA (2.02-2.12 GHz)B (2.20-2.30 GHz)
C-BandA (5.850-6.425 GHz)B (5.750-6.475 GHz)C (5.750-6.670 GHz)D (5.850-6.725 GHz)E (6.425-6.725 GHz)F (6.725-7.025 GHz)
X-BandA (7.70-8.40 GHz)B (7.90-8.40 GHz)C (7.50-8.50 GHz)
D (9.50-10.50 GHz)Ku-Band
A (14.00-14.50 GHz)B (13.75-14.50 GHz)C (12.75-13.25 GHz)D (13.00-14.50 GHz)E (13.25-13.75 GHz)
Ka-BandA (27.5-31.0 GHz)
EnclosureI - IndoorO - Outdoor
Block Up ConverterB - BUCX – Not Available
Configuration/Options
STD – Standard
ISP – Input Sample Port
WGF* – 90° Output W/G Flange
WSP *– 90° Output W/G Flange with Input Sample Port
FPS** – Front Panel Power Switch
RPM – Reflected Power Monitor
FRM** – Front Panel Power Switch and Reflected Power Monitor
EPS – External, Redundant Power Supply, 1RU N+1
EPE – External Power Supply, 1RU N+1 and Rear Panel
* Available in all but S-Band-and L-Bands** Not Available with External 1RU N+1
Redundant Power Supply