orthographic views of perspective views of - 5828w34-3 x 2 high.pdf · perspective views of...

3
TOP VIEW OF SPACER STATION SIDE VIEW OF SPACER STATION FRONT VIEW OF SPACER STATION

Upload: others

Post on 23-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ORTHOGRAPHIC VIEWS OF PERSPECTIVE VIEWS OF - 5828W34-3 X 2 HIGH.pdf · perspective views of wunpeece spacers orthographic views of wunpeece spacers %%uscale: 1.000. use of the products

TOP VIEW OFSPACER STATION

SIDE VIEW OFSPACER STATION

FRONT VIEW OFSPACER STATION

AutoCAD SHX Text
C
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
Don McCoy
AutoCAD SHX Text
NORTHBROOK, ILLINOIS 60062 - PHONE: (847) 205-9000
AutoCAD SHX Text
UNDERGROUND DEVICES, INC.
AutoCAD SHX Text
See At Left
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DETAILED BY:
AutoCAD SHX Text
DRAWING NUMBER:
AutoCAD SHX Text
PAGE 1 OF 3
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
Don McCoy
AutoCAD SHX Text
%%USCALE:
AutoCAD SHX Text
1.000
AutoCAD SHX Text
A
AutoCAD SHX Text
MAY 21, 2019 - ALL RIGHTS RESERVED BY UNDERGROUND DEVICES, INC.
AutoCAD SHX Text
90-11053
AutoCAD SHX Text
5-21-19
AutoCAD SHX Text
Steve Wendland
AutoCAD SHX Text
CONDUIT DIMENSIONS
AutoCAD SHX Text
CONDUIT OD
AutoCAD SHX Text
NOMINAL
AutoCAD SHX Text
ACTUAL
AutoCAD SHX Text
2"
AutoCAD SHX Text
2.375
AutoCAD SHX Text
5"
AutoCAD SHX Text
5.563
AutoCAD SHX Text
NOTES: 1. USE ONE "SPACER STATION" FOR EVERY 5 FEET USE ONE "SPACER STATION" FOR EVERY 5 FEET OF DUCT BANK. 2. PARTS REQUIRED FOR THE SPACER STATION: PARTS REQUIRED FOR THE SPACER STATION: 2 EA. 5828W34-3 WUNPEECE SPACERS 3. SPACERS INTERLOCK HORIZONTALLY AND ARE STAGGERED VERTICALLY FOR A MORE STRUCTURALLY SOUND DUCT BANK. THE VERTICAL STAGGER ELIMINATES WEAK VERTICAL SHEAR PLANES IN THE CONCRETE ENCASEMENT. 4. WE SUGGEST THAT THE CONCRETE USED WITH THESE THESE SPACERS HAVE A SLUMP OF 7 TO 8 INCHES. IT SHOULD HAVE JUST ENOUGH SLUMP TO FLOW TO THE BOTTOM OF THE DUCT BANK AND YET NOT BE SO WET THAT IT CAUSES THE CONDUITS TO FLOAT EXCESSIVELY. CONDUITS TO FLOAT EXCESSIVELY. 5. TO AID IN THE CONCRETE FLOW THE AGGREGATE SIZE TO AID IN THE CONCRETE FLOW THE AGGREGATE SIZE SHOULD BE CONTROLLED. 3/8" MAXIMUM AGGREGATE IS OFTEN SPECIFIED. 6. WHEN PLACING CONCRETE AROUND CONDUITS ADJUST THE WHEN PLACING CONCRETE AROUND CONDUITS ADJUST THE DELIVERY CHUTE SO THE FALL OF THE CONCRETE IS MINIMAL. POUR THE CONCRETE SLOWLY AND DISTRIBUTE IT EVENLY SO AS NOT TO DISLODGE THE SPACERS. 7. THE DUCT BANK MUST BE HELD DOWN DURING AND THE DUCT BANK MUST BE HELD DOWN DURING AND IMMEDIATELY AFTER THE CONCRETE POUR. THIS IS NECESSARY DUE TO THE FLOATATION CAUSED BY DUCT BANK BUOYANCY AND CONCRETE CHURNING. 8. HOLD DOWN HARDWARE, PLASTIC CABLE TIES AND ANY HOLD DOWN HARDWARE, PLASTIC CABLE TIES AND ANY REBAR THAT MAY BE REQUIRED IS NOT SHOWN IN THIS DRAWING. 9. THE CONDUIT SPECIFICATIONS SHOWN ON THIS DRAWING THE CONDUIT SPECIFICATIONS SHOWN ON THIS DRAWING ARE FOR VISUAL PRESENTATION ONLY. 10. CONDUIT, PLASTIC CABLE TIES AND ANY REBAR THAT MAY CONDUIT, PLASTIC CABLE TIES AND ANY REBAR THAT MAY BE REQUIRED IS TO BE SUPPLIED BY OTHERS.
AutoCAD SHX Text
With 4 Ea. 8", 2 Ea. 5", & 4 Ea. 2" Sch.40 PVC Conduits
AutoCAD SHX Text
SPACER STATION OUTLINE DRAWING
AutoCAD SHX Text
8"
AutoCAD SHX Text
8.625
AutoCAD SHX Text
5828W34-3 WUNPEECE
AutoCAD SHX Text
8
AutoCAD SHX Text
5
AutoCAD SHX Text
8
AutoCAD SHX Text
2
AutoCAD SHX Text
8
AutoCAD SHX Text
5
AutoCAD SHX Text
2
AutoCAD SHX Text
(2 REQ'D PER SPACER STATION)
AutoCAD SHX Text
8.625
AutoCAD SHX Text
8
AutoCAD SHX Text
UNDERGROUND DEVICES
AutoCAD SHX Text
CATALOG NUMBER:
AutoCAD SHX Text
5828W34-3 (2 EACH)
AutoCAD SHX Text
R
AutoCAD SHX Text
R
AutoCAD SHX Text
1st Designed For UDI LIBRARY OF
AutoCAD SHX Text
OUTLINE & INSTALLATION DRAWINGS FOR AutoCAD
AutoCAD SHX Text
AutoCAD is a registered trademark of Autodesk, Inc.
AutoCAD SHX Text
WUNPEECE is a registered trademark of UNDERGROUND DEVICES, INC.
AutoCAD SHX Text
CONDUITS USED FOR
AutoCAD SHX Text
TEMPERATURE MONITORING,
AutoCAD SHX Text
COMMUNICATIONS AND/OR
AutoCAD SHX Text
CONTROL CABLES.
AutoCAD SHX Text
(2 PER SPACER)
AutoCAD SHX Text
OPTIONAL 2" NOMINAL
AutoCAD SHX Text
2.563 DIA. HOLES FOR
Page 2: ORTHOGRAPHIC VIEWS OF PERSPECTIVE VIEWS OF - 5828W34-3 X 2 HIGH.pdf · perspective views of wunpeece spacers orthographic views of wunpeece spacers %%uscale: 1.000. use of the products

PERSPECTIVE VIEWS OFWUNPEECE SPACERS

ORTHOGRAPHIC VIEWS OFWUNPEECE SPACERS

AutoCAD SHX Text
%%USCALE:
AutoCAD SHX Text
1.000
AutoCAD SHX Text
USE OF THE PRODUCTS DESCRIBED.
AutoCAD SHX Text
THIS INFORMATION IS BASED ON OUR EXPERIENCE TO DATE AND WE
AutoCAD SHX Text
RESULTS AND ASSUME NO LIABILITY IN CONNECTION WITH ITS USE OR
AutoCAD SHX Text
USE AT YOUR DISCRETION AND RISK. WE CANNOT GUARANTEE FAVORABLE
AutoCAD SHX Text
BELIEVE IT TO BE RELIABLE. IT IS INTENDED ONLY AS A GUIDE FOR
AutoCAD SHX Text
THIS DRAWING AND PROPRIETARY DESIGN IS SOLELY THE PROPERTY OF UNDERGROUND DEVICES, INC. AND IS SUBMITTED WITH THE UNDERSTANDING THAT IT WILL BE KEPT IN STRICT CONFIDENCE.
AutoCAD SHX Text
C
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
Don McCoy
AutoCAD SHX Text
NORTHBROOK, ILLINOIS 60062 - PHONE: (847) 205-9000
AutoCAD SHX Text
UNDERGROUND DEVICES, INC.
AutoCAD SHX Text
See At Left
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DETAILED BY:
AutoCAD SHX Text
DRAWING NUMBER:
AutoCAD SHX Text
PAGE 2 OF 3
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
Don McCoy
AutoCAD SHX Text
A
AutoCAD SHX Text
MAY 21, 2019 - ALL RIGHTS RESERVED BY UNDERGROUND DEVICES, INC.
AutoCAD SHX Text
90-11053
AutoCAD SHX Text
5-21-19
AutoCAD SHX Text
1st Designed For UDI LIBRARY OF
AutoCAD SHX Text
OUTLINE & INSTALLATION DRAWINGS FOR AUTOCAD
AutoCAD SHX Text
Steve Wendland
AutoCAD SHX Text
R
AutoCAD SHX Text
With 4 Ea. 8", 2 Ea. 5", & 4 Ea. 2" Sch.40 PVC Conduits
AutoCAD SHX Text
SPACER STATION OUTLINE DRAWING
AutoCAD SHX Text
5828W34-3 WUNPEECE
AutoCAD SHX Text
R
Page 3: ORTHOGRAPHIC VIEWS OF PERSPECTIVE VIEWS OF - 5828W34-3 X 2 HIGH.pdf · perspective views of wunpeece spacers orthographic views of wunpeece spacers %%uscale: 1.000. use of the products

PERSPECTIVE VIEW OFDUCT BANK

AutoCAD SHX Text
USE OF THE PRODUCTS DESCRIBED.
AutoCAD SHX Text
THIS INFORMATION IS BASED ON OUR EXPERIENCE TO DATE AND WE
AutoCAD SHX Text
RESULTS AND ASSUME NO LIABILITY IN CONNECTION WITH ITS USE OR
AutoCAD SHX Text
USE AT YOUR DISCRETION AND RISK. WE CANNOT GUARANTEE FAVORABLE
AutoCAD SHX Text
BELIEVE IT TO BE RELIABLE. IT IS INTENDED ONLY AS A GUIDE FOR
AutoCAD SHX Text
THIS DRAWING AND PROPRIETARY DESIGN IS SOLELY THE PROPERTY OF UNDERGROUND DEVICES, INC. AND IS SUBMITTED WITH THE UNDERSTANDING THAT IT WILL BE KEPT IN STRICT CONFIDENCE.
AutoCAD SHX Text
C
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
Don McCoy
AutoCAD SHX Text
NORTHBROOK, ILLINOIS 60062 - PHONE: (847) 205-9000
AutoCAD SHX Text
UNDERGROUND DEVICES, INC.
AutoCAD SHX Text
See At Left
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DETAILED BY:
AutoCAD SHX Text
DRAWING NUMBER:
AutoCAD SHX Text
PAGE 3 OF 3
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
Don McCoy
AutoCAD SHX Text
Steve Wendland
AutoCAD SHX Text
1st Designed For UDI LIBRARY OF
AutoCAD SHX Text
OUTLINE & INSTALLATION DRAWINGS FOR AUTOCAD
AutoCAD SHX Text
R
AutoCAD SHX Text
A
AutoCAD SHX Text
MAY 21, 2019 - ALL RIGHTS RESERVED BY UNDERGROUND DEVICES, INC.
AutoCAD SHX Text
90-11053
AutoCAD SHX Text
5-21-19
AutoCAD SHX Text
With 4 Ea. 8", 2 Ea. 5", & 4 Ea. 2" Sch.40 PVC Conduits
AutoCAD SHX Text
SPACER STATION OUTLINE DRAWING
AutoCAD SHX Text
5828W34-3 WUNPEECE
AutoCAD SHX Text
R