no a project office basis of estimate form (boe)
TRANSCRIPT
NOvA/ANU BoE Form Page 1 of 2
NOνA Project Office BASIS of ESTIMATE FORM (BoE)
Document Number: 2087
Date of Estimate: May 28, 2007
Prepared by: Andrew Norman
UID Number:
WBS Section: 2.7.4.1.2.1
Task Name: Environmental and water cooling system sensor readout stations
Cost Type: Costing Method: ___Engineering Estimate
Prior purchase or experience Source:
_X__ Catalog Price Source: National Insturments
_ X_ M&S _ _Labor _X_Vendor Quote (attached) __ Other- Description:_____________________________ Attach Relevant Documents (including but not limited to): RFP, Responses to RFP, Technical Evaluation of RFP, Vendor Quotes, Technical Specifications, drawing numbers Task Duration: (calendar weeks, 85% achievable): see table below
Task M&S Cost (FY07$): $224,160 See cost table below Task M&S Contingency (%): 10% See cost table below
Task Labor (resource type & work hours or % for duration of task, 85% efficiency assumed): See cost table below Task Labor Contingency (%):See cost table below
Details of Estimate: Estimate is based upon 40 readout stations in the following base configuration: Configuration 1: Part Number Description Number Cost Total 778617-08 cFP-BP-8 8-Slot Backplane 1 549.00 549.00 779463-01 cFP-1808, 8-slot Ethernet/Serial Interface for Compact
FieldPoint 1 999.00 999.00
777584-01 PS-2 Power Supply, 24 VDC, 0.8 A, US (120 VAC) 1 79.00 79.00 777318-122 cFP-RTD-122, 16 Bit RTD Input Module (RTD, Ohms) 2 469.00 938.00 777318-550 cFP-DIO-550, Digital Input/Output Module (AC-DC sink/DC
source) 1 279.00 279.00
777318-500 cFP-CTR-500, Counter Input Module 1 429.00 429.00 777318-112 cFP-AI-112 16 ch, 16-Bit Analog Input Module (V) 4 599.00 2,396.00 Total: 5,669.00 Configuration 2: Part Number Description Number Cost Total 778617-08 cFP-BP-8 8-Slot Backplane 1 549.00 549.00 779463-01 cFP-1808, 8-slot Ethernet/Serial Interface for Compact
FieldPoint 1 999.00 999.00
777584-01 PS-2 Power Supply, 24 VDC, 0.8 A, US (120 VAC) 1 79.00 79.00 777318-122 cFP-RTD-122, 16 Bit RTD Input Module (RTD, Ohms) 2 469.00 938.00 777318-550 cFP-DIO-550, Digital Input/Output Module (AC-DC sink/DC
source) 1 279.00 279.00
777318-304 cFP-DI-304, 32-channel sinking Digital Input Module, 10-30 VDC
1 299.00 299.00
777318-112 cFP-AI-112 16 ch, 16-Bit Analog Input Module (V) 4 599.00 2,396.00 Total: 5,539.00
NOvA/ANU BoE Form Page 2 of 2
See attached quotes and catalog pages for details of exact pricing for large orders.
My Shopping Cart (US Dollars) - National Instruments http://sine.ni.com/apps/utf8/nios.store
1 of 1 5/28/2007 1:01 AM
My Shopping Cart ( US Dollars )Questions? Call me now! or (866) 337-8762
Total Items: 11Subtotal: $ 5,669.00
Shipping in United States FedEx 2-DayFedEx 2-Day $ 50.88
Order Total: $ 5,719.88
Part Number Description Est Ship Unit Price Qty Line Total
779463-01 cFP-1808, 8-slot Ethernet/Serial Interface for Compact FieldPoint 5 - 10 $ 999.00 $ 999.00
778617-08 cFP-BP-8 8-Slot Backplane 5 - 10 $ 549.00 $ 549.00
777584-01 PS-2 Power Supply, 24 VDC, 0.8 A, US (120 VAC) 1 - 2 $ 79.00 $ 79.00
777318-112 cFP-AI-112 16 ch, 16-Bit Analog Input Module (V) 1 - 2 $ 599.00 $ 2,396.00
777318-550 cFP-DIO-550, Digital Input/Output Module (AC-DC sink/DC source) 1 - 2 $ 279.00 $ 279.00
777318-500 cFP-CTR-500, Counter Input Module 1 - 2 $ 429.00 $ 429.00
777318-122 cFP-RTD-122, 16 Bit RTD Input Module (RTD, Ohms) 1 - 2 $ 469.00 $ 938.00
Click the symbol to remove the item
Your Cart Options
Place Order Now
Print and Fax Order
Get Instant Quote
Save and Share Cart
Print Cart
Download to Excel
My Profile | Privacy | Legal | Contact NI © 2007 National Instruments Corporation. All rights reserved.
1
1
1
4
1
1
2
My Shopping Cart (US Dollars) - National Instruments http://sine.ni.com/apps/utf8/nios.store
1 of 1 5/28/2007 1:02 AM
My Shopping Cart ( US Dollars )Questions? Call me now! or (866) 337-8762
Total Items: 11Subtotal: $ 5,539.00
Shipping in United States FedEx 2-DayFedEx 2-Day $ 49.02
Order Total: $ 5,588.02
Part Number Description Est Ship Unit Price Qty Line Total
779463-01 cFP-1808, 8-slot Ethernet/Serial Interface for Compact FieldPoint 5 - 10 $ 999.00 $ 999.00
778617-08 cFP-BP-8 8-Slot Backplane 5 - 10 $ 549.00 $ 549.00
777584-01 PS-2 Power Supply, 24 VDC, 0.8 A, US (120 VAC) 1 - 2 $ 79.00 $ 79.00
777318-112 cFP-AI-112 16 ch, 16-Bit Analog Input Module (V) 1 - 2 $ 599.00 $ 2,396.00
777318-550 cFP-DIO-550, Digital Input/Output Module (AC-DC sink/DC source) 1 - 2 $ 279.00 $ 279.00
777318-122 cFP-RTD-122, 16 Bit RTD Input Module (RTD, Ohms) 1 - 2 $ 469.00 $ 938.00
777318-304 cFP-DI-304, 32-channel sinking Digital Input Module, 10-30 VDC 5 - 10 $ 299.00 $ 299.00
Click the symbol to remove the item
Your Cart Options
Place Order Now
Print and Fax Order
Get Instant Quote
Save and Share Cart
Print Cart
Download to Excel
My Profile | Privacy | Legal | Contact NI © 2007 National Instruments Corporation. All rights reserved.
1
1
1
4
1
2
1
522 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.com
Com
pact
Fie
ldPo
int B
ackp
lane
sIn
dust
rial
Con
trol
and
Dis
trib
uted
I/O
Overview National Instruments offers two backplanes for mounting Compact
FieldPoint modules – the cFP-BP-4 (4 slots) and the cFP-BP-8
(8 slots). Both backplanes, which are constructed of extruded metal
with grounding lugs on the bottom, feature screw-down connections
for a controller module, four or eight I/O modules, and 37 pin D-Sub
connectors for I/O connections. The backplanes all come with a
cFP-PM-H horizontal mounting bracket, which provides mounting
holes on either side of the backplane so you can mount it to a panel.
For other mounting options, you can purchase a vertical panel
mount, a DIN rail mount, or a 19 in. rack mount separately.
Compact FieldPoint and FieldPointThese backplanes are used with Compact FieldPoint only. Compact
FieldPoint is designed for industrial control applications that perform
advanced embedded control, data logging, headless operation, and
Ethernet connectivity. Compact FieldPoint is our most rugged and
reliable platform and is designed for industrial and mobile
environments with high shock, vibration, and temperature extremes.
FieldPoint is a lower-cost distributed I/O system with a variety of
communication options besides Ethernet. It is designed to mount on
DIN rails in static applications where the FieldPoint bank is connected
to a PC for data collection, analysis, display, and storage.
• 4 and 8-slot backplanes • Solid metal construction for rugged
installations • Panel, DIN rail, and 19 in. rack
mounting • Local bus for communications
and module power • Secure screw mounting for I/O
and control modules • -25 to 60 °C operating range
NI cFP-BP-4, NI cFP-BP-8
Compact FieldPoint BackplanesNEW
Back Plane I/O Module Slots Standard Mounting HardwarecFP-BP-4 4 cFP-PM-H horizontal panel mounting bracketcFP-BP-8 8 cFP-PM-H horizontal panel mounting bracket
Figure 1. Dimensions of the Compact FieldPoint systems with the cFP-BP-4 and cFP-BP-8 backplanes.
CablingClearance
Cooling Outline51 mm (2 in.)
All Around
4 slots = 246 mm (9.68 in.)8 slots = 441 mm (17.4 in.)
127
mm
(5.0
0 in
.)
Min
. 165
mm
(6
.50
in.)
CablingClearance
4 slots = 246 mm (9.68 in.)8 slots = 441 mm (17.4 in.)
Cooling Outline 51 mm (2 in.)
Cooling Outline 51 mm (2 in.)
Min
. 182
mm
(7.1
8 in
.)
106
mm
(4.1
8 in
.)
Compact FieldPoint BackplanesHigh Shock and VibrationTo withstand high levels of shock and vibration, Compact FieldPoint
backplanes are made of extruded metal and provide a rigid
mounting surface for the Compact FieldPoint modules. The
backplane also provides screw-down connections for the controller
module, I/O modules, and connector blocks.
Mounting NI offers four mounting options for Compact FieldPoint
backplanes including panel mounting, DIN-rail mounting, and
19 in. rack mounting.
Compact FieldPoint System ConfigurationCompact FieldPoint I/O modules mount on either the cFP-BP-4 or
cFP-BP-8 backplane. The backplane also contains a controller
module, which runs embedded LabVIEW Real-Time and can
connect over Ethernet to a PC, to other FieldPoint banks, to Web
browsers, or to other Ethernet devices. The Compact FieldPoint
backplane also provides a 37-pin D-Sub connector to connect your
field signal wiring for each I/O module. You have three options to
connect field wiring to this 37-pin D-Sub connector:
1. Using an integrated connector block such as the cFP-CB-1
or cFP-CB-11;
2. Using a cable to an external connector block mounted on a DIN rail;
3. Making your own custom cable.
For more details on configuring your Compact FieldPoint system,please see 517.
523National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.com
Compact FieldPoint B
ackplanesIndustrial Control and D
istributed I/O
Number Needed to Number Needed toMounting Option Description Mount cFP-BP-4 Mount cFP-BP-8cFP-PM-H Panel mount with bolt holes at 1 1
the sides of the backplane.(included with all backplane)
cFP-PM-V Panel mount with bolt holes at the 1 1top and bottom of the backplane
cFP-RM-8 19 in. rack mount. Features captive 1 1screws for easy mounting and
cutouts for running grounding cablesDIN rail DIN rail clip for cFP-BP-4 1 2*mounting clip
* DIN rail mounting is not recommended for the cFP-BP-8NI cFP-BP-4 ..................................................................778617-04NI cFP-BP-8 ..................................................................778617-08
Recommended Compact FieldPoint System ProductsNI cFP-2020 ..............................................................777317-2020NI cFP-CB-1 ..................................................................778618-01NI PS-5 Power Supply ..................................................778805-90NI Developer Suite Professional Control Edition..........777906-03
BUY ONLINE!Visit ni.com/info and enter cfppb4, and/or cfppb8.
Ordering Information
Compact FieldPoint Accessories
Mounting Options (see figures 1, 2, and 3)NI offers four mounting options for Compact FieldPoint, including panel mounting, DIN rail mounting, and 19 in. rack mounting.
Power Supplies (see Figure 4)National Instruments offers five DC supplies for Compact FieldPoint systems. You connect the power supply output to the Compact FieldPoint
controller, which regulates, filters, and distributes power to the bank of up to eight I/O modules that it controls. All five power supplies can power an
entire bank of Compact FieldPoint I/O modules. The PS-5 mounts on a DIN rail and is recommended for most Compact FieldPoint installations.
Stand-Alone Controller-Mounting Accessories (see Figure 5)National Instruments offers options for mounting stand-alone Compact FieldPoint controllers. These accessories support applications for redundant
controllers without redundant I/O. The panel and DIN rail-mounting kits also provide mounting options for a stand-alone Compact FieldPoint real-time
controller running LabVIEW Real-Time software. Controller-mounting options include panel and DIN rail-mounting.
Figure 1. cFP-PM-V,Vertical-Mounting Kit
Figure 2. cFP-PM-H,Horizontal-Mounting Kit
Figure 3. cFP-RM-8,Rack-Mounting Kit
Figure 4. PS-5 PowerSupply (24 VDC)
Figure 5. Panel and DIN Rail-Mounting Kits
Mounting Option Description Quantity Needed to Mount cFP-BP-4 Quantity Needed to Mount cFP-BP-8 Part NumbercFP-PM-H Panel mount with bolt holes at the sides of
the backplane (included with all backplane)1 1 778616-01
cFP-PM-V Panel mount with bolt holes at the top and bottom of the backplane
1 1 778688-01
cFP-RM-8 19 in. rack mount; features captive screws for easymounting and cutouts for running grounding cables
1 1 778615-01
DIN Rail-Mounting Clip DIN rail clip for cFP-BP-4 1 21 778614-011DIN rail mounting is not recommended for the cFP-BP-8.
Model Output Voltage (VDC) Output Current (A) Input Voltage Part NumberPS-1 20 0.8 120 VDC 777567-01
PS-2 24 0.8 P = 1 U.S. 120/Japan 100 VAC2 Swiss 220 VAC, 3 Australian4 Universal Euro 240 VAC5 North American 240 VAC6 United Kingdom 240 VAC
777584-0P
PS-3 13.8 4 Same as PS-2 777585-0P
PS-4 24 0.625 90 to 260 VAC 50/60 Hz 778586-90PS-5 24 5 90 to 260 VAC 50/60 Hz 778805-90
Power connects to the cFP-21xx modules, which regulate, filter, and distribute to attached I/O modules.
Model Description Part NumberPanel Panel-mounting kit for stand-alone controllers 779549-01
DIN rail DIN rail-mounting kit for stand-alone controllers 779552-01
BUY NOW!For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S.) or go to ni.com/compactfieldpoint.
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and CertificationNI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional ServicesOur Professional Services Team is comprised of NI applications engineers,
NI Consulting Services, and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range from
start-up assistance to turnkey
system integration.
Visit ni.com/alliance.
OEM SupportWe offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Local Sales and Technical SupportIn offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation ServicesNI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online with
ni.com/pxiadvisor.
Calibration Services NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
SERVICE NEEDS
© 2006 National Instruments Corporation. All rights reserved. FieldPoint, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
National Instruments • [email protected]
ni.com • (800) 813 3693 *351355A-01*351355A-01 2006-6643-161-101-D
Overview and Distributed ApplicationsNational Instruments cFP-180x interfaces connect four or eight
Compact FieldPoint I/O modules to a high-speed Ethernet network or to
an RS232 serial port. With up to 100 Mb/s data communication rates and
event-driven communications, an NI cFP-180x delivers a high-performance
network connection for Compact FieldPoint that is easy to interface with
a PC or PAC-like Compact FieldPoint embedded controller. One or more
cFP-180x interfaces, connected by standard networking equipment, provide
expanded I/O that you can control with a single Compact FieldPoint
controller, see Figure 1. You can also build a PC-based distributed I/O and
control system by connecting two or more cFP-180x devices to your PC.
Hardware ArchitectureA cFP-180x provides an integrated network interface (Ethernet or serial)
and a 4 or 8-slot backplane, and it works with the same modules and
connector blocks used in other Compact FieldPoint systems.
Building Ethernet-Based Distributed I/O SystemsA cFP-180x can communicate with Compact FieldPoint real-time
embedded controllers; any Ethernet-based programmable automation
controller (PAC); and a Windows computer running LabVIEW,
LabWindows/CVI, Measurement Studio, Lookout, or your choice of OPC
client application software. Using a cFP-180x, you can rapidly build
flexible, modular distributed measurement and automation systems.
Ethernet/Serial Interfaces for Compact FieldPoint
• Distributed I/O interfaces for Ethernetand RS232 networks
• 4 or 8-slot Compact FieldPoint distributedEthernet/serial network interfaces
• FieldPoint software for rapid distributedI/O access
• Modbus Support• OPC server included• Intelligent diagnostics and maintenance • Industrial specifications for
harsh environments• 50 g shock• 5 g vibration• -40 to 70 °C
Operating Systems• Windows 2000/XP
Recommended Software• LabVIEW• LabVIEW Datalogging and Supervisory
Control Module
Other Compatible Software• LabWindows/CVI• Measurement Studio• Lookout• VI Logger
Driver Software (included)• Measurement & Automation Explorer• OPC server (2.0 compliant)
NI cFP-180x
Compact FieldPoint
Real-Time Controller
NI cFP-1808 Distributed
Network Interfaces
Ethernet
Figure 1. Expansion I/O for Compact FieldPoint Embedded Controller with cFP-1808Network Interfaces
Figure 2. cFP-1808 Mechanical Dimensions
127 mm(5.00 in.)
441 mm(17.36 in.)
Figure 3. cFP-1804 Mechanical Dimensions
127.0 mm(5.00 in.)
245.9 mm (9.68 in.)
Ethernet/Serial Interfaces for Compact FieldPoint
2
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
Network Communications InterfaceA cFP-180x connects directly to Ethernet networks, autonegotiating on
the network for 10 Mb/s or 100 Mb/s communication rates. It includes
an RJ-45 connector for connection to 10BaseT and 100BaseTX networks,
using a protocol based on standard TCP/IP to maintain full compatibility
with existing networks. FieldPoint builds on standard TCP/IP network
protocols and adds a number of key enhancements, including event-
driven communications and publisher-subscriber networking. In a
publisher-subscriber architecture, one or more client PCs subscribe to
I/O data from Compact FieldPoint banks. The network interface monitors
connected I/O modules and publishes I/O data only when the value
changes. Analog signals can change value within selectable ranges,
called deadbands, without causing the system to report data. This
event-driven method, along with data compression, helps you avoid
unnecessary Ethernet traffic and maximizes communication efficiency.
A cFP-180x also includes a standard DB-9 connector for RS232 serial
communication. Through direct connectivity, you can read and write
data directly from a program running on your PC or embedded controller.
You access I/O through the serial interface using a serial protocol called
Optomux, in the same way you would access data through classic
FieldPoint network interfaces such as the FP-1000.
Configuring and Accessing Tags on aCompact FieldPoint System with LabVIEW 8National Instruments LabVIEW 8 and Compact FieldPoint create a
flexible PAC system that offers easy-to-access I/O through the FieldPoint
programming environment. Accessing data from multiple cFP-180x
distributed nodes with LabVIEW is as easy as three simple steps:
1. Configure IP address using NI Measurement & Automation Explorer (MAX)
2. Import a FieldPoint configuration file or add a new
Compact FieldPoint system
3. Expand I/O in the LabVIEW Project and drag and drop I/O tags to VIs
After configuring the IP address for a FieldPoint bank in MAX, either
import the configuration file created from MAX, or simply add a new
target to a LabVIEW Project as shown in Figure 5.
After adding all FieldPoint networks available on the network, you can
expand each FieldPoint bank and see the I/O modules and tags available
from the LabVIEW Project Explorer. Using these tags in an application is
as easy as dragging the tag from the Project Explorer to the VI where the
data is needed. LabVIEW automatically creates the correct FieldPoint
read/write VI and associated tag.
Figure 5. Add a new FieldPoint target to your LabVIEW 8 Project.
HMIs and
Touch Panels
Programmable
Automation
Controllers
Compact FieldPoint
Real-Time Controller
Distributed Compact FieldPoint
Network Interface
Figure 4. Ethernet-based distributed systems work with Compact FieldPoint embedded controllers, PACs, human-machine interfaces, and Enterprise/SCADA systems.
Enterprise Level
Ethernet/Serial Interfaces for Compact FieldPoint
3
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
Accessing Network I/O Data on a cFP-180x Using Shared VariablesYou can create a shared variable for any tag that is available on a
cFP-180x bank connected to the network. You then can use this shared
variable in multiple LabVIEW applications either targeted to Windows OS
or running embedded on a Compact FieldPoint real-time controller such as
the NI cFP-2120. To create a shared variable to be hosted on a Windows
system, simply right-click on My Computer in the LabVIEW Project and
select New Variable; select the option to bind this shared variable to a
source, and then you can either select IO from your local LabVIEW Project
or any I/O available on the network, as shown in Figure 7.
After you create a shared variable, it appears in LabVIEW Project
Manager and is available for use in your LabVIEW applications simply
by dragging the variable from the Project Explorer to an existing VI
(see Figure 8). From a PC, PAC, or embedded Compact FieldPoint controller,
you can use MAX with LabVIEW 8 to configure I/O settings for the
cFP-180x to access data on distributed Compact FieldPoint banks.
Accessing distributed I/O is now easier than ever with LabVIEW 8
and a cFP-180x.
Ordering Information
NI cFP-1808 ...........................................................................779463-01
NI cFP-1804 ...........................................................................779490-01
PS-5 (power supply 24 VDC, 5 A, universal power input) ......778805-90
BUY NOW!For complete product specifications, pricing, and accessoryinformation, call (800) 813 3693 (U.S.) or go to ni.com/fieldpoint.
Figure 6. Drag and drop an I/O tag from a LabVIEW Project to any VI.
Figure 7. Compact FieldPoint distributed I/O channels are accessible as network itemsfrom LabVIEW.
Figure 8. Use a shared variable to access distributed I/O for all channels.
Ethernet/Serial Interfaces for Compact FieldPoint
4
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
SpecificationsNetworkNetwork interface............................... 10BaseT and 100BaseTX EthernetCompatibility ....................................... IEEE802.3Communication rates .......................... 10 or 100 Mb/s, autonegotiatedMaximum cabling distance................. 100 m/segmentMaximum power to I/O modules........ 9 WMaximum number of banks ................ Determined by network topology
Serial PortOne RS232 (DCE) serial port
Baud rate ........................................ 300 to 115,200 b/sData bits ......................................... 8Stop bits.......................................... 1Parity ............................................... NoneFlow control .................................... None
Power RequirementPower supply range ............................ 11 to 30 VDCRecommended power supply.............. 20 WPower consumption ............................ 6.1 W + 1.1 (I/O module)
Safety Isolation VoltageIsolation voltage is verified by a dielectric withstand test betweenmodule and backplane.Continuous .......................................... 250 Vrms,
Measurement Category IIWithstand............................................ 2,300 Vrms, 5 s max
Physical CharacteristicsScrew-terminal wiring ........................ 14 to 22 AWG copper wire with
7 mm (0.28 in.) of insulationstripped from the end
Torque for screw terminals................. 0.5 to 0.6 N • m(4.4 to 5.3 lb • in.)
WeightcFP-1804 ......................................... 935 g (2 lb 1 oz)cFP-1808 ......................................... 1,595 g (3 lb 8 oz)
EnvironmentalFieldPoint modules are intended for indoor use only. For outdoor use,they must be installed in a suitable sealed enclosure.
Operating temperature ....................... -40 to 70 °CStorage temperature........................... -55 to 85 °CRelative humidity ................................ 10 to 90%, noncondensingMaximum altitude............................... 2,000 m; at higher altitudes
the isolation voltage ratingsmust be lowered
Pollution Degree ................................. 2
Shock and VibrationOperating vibration
Random (IEC 60068-2-64) ............... 10 to 500 Hz, 5 grmsSinusoidal (IEC 60068-2-6) ............. 10 to 500 Hz, 5 g
Operating shock(IEC 60068-2-27) ............................. 50 g, 3 ms half sine, 18 shocks at
6 orientations; 30 g, 11 ms halfsine, 18 shocks at 6 orientations
SafetyThis product is designed to meet the requirements of the followingstandards of safety for electrical equipment for measurement, control,and laboratory use:
• IEC 61010-1, EN 61010-1• UL 61010-1• CAN/CSA-C22.2 No. 61010-1
Note: For UL, hazardous location, and other safety certifications, refer to the product label orvisit ni.com/certification, search by model number or product line, and click the appropriatelink in the Certification column.
Electromagnetic CompatibilityEmissions ............................................ EN 55011 Class A at 10 m
FCC Part 15A above 1 GHzImmunity.............................................. EN 61326:1997 + A2:2002, Table 1
CE, C-Tick, and FCC Part 15(Class A) Compliant
Note: For EMC compliance, operate this device with shielded cabling.
CE ComplianceThis product meets the essential requirements of applicable Europeandirectives, as amended for CE marking, as follows:
Low-voltage directive (safety) ............ 73/23/EECElectromagnetic compatibilitydirective (EMC).................................... 89/336/EECNote: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatorycompliance information. To obtain the DoC for this product, visit ni.com/certification, searchby model number or product line, and click the appropriate link in the Certification column.
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and CertificationNI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional ServicesOur Professional Services Team is comprised of NI applications engineers,
NI Consulting Services, and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range from
start-up assistance to turnkey
system integration.
Visit ni.com/alliance.
OEM SupportWe offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Local Sales and Technical SupportIn offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation ServicesNI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online with
ni.com/pxiadvisor.
Calibration Services NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
SERVICE NEEDS
© 2006 National Instruments Corporation. All rights reserved. CVI, FieldPoint, LabVIEW, Lookout, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
National Instruments • [email protected]
ni.com • (800) 813 3693 *342572A-01*342572A-01 2006-6507-161-101-D
Thermocouple and RTD Modules for Compact FieldPoint
OverviewThe National Instruments cFP-TC-12x and cFP-RTD-12x are versatile
temperature input modules for Compact FieldPoint, used to measure
thermocouples, millivolt-level voltages, thermistors, and 2, 3, and 4-wire
RTDs. They are used in applications such as temperature chamber control,
device testing, and process control. Thermocouples are low-cost, flexible
temperature devices. RTD sensors are used in applications for acquiring
temperatures with high accuracy. Two and 3-wire RTDs work well for
applications with short signal wires and low noise levels; 4-wire RTDs are
well-suited for applications with long signal wires or high noise levels.
All of these I/O modules include overranging and onboard diagnostics to
ensure trouble-free installation and maintenance. The modules measure
and linearize signals on board to return scaled values to your control or
monitoring software. NI cFP-TC-12x and cFP-RTD-12x modules have NIST-
traceable calibration certificates (available on request), ensuring accurate
and reliable analog measurements.
Compact FieldPointCompact FieldPoint is designed for industrial control applications that
perform advanced embedded control, data logging, headless operation,
and Ethernet connectivity. Compact FieldPoint, a rugged, reliable NI platform,
is designed for industrial and mobile environments with high shock,
vibration, and temperature extremes.
IsolationThe cFP-TC-125 provides 250 Vrms common-mode voltage protection
between channels, and all cFP-TC-12x and cFP-RTD-12x modules
feature optical bank isolation with 2,300 Vrms of breakdown isolation.
In addition, the cFP-TC-12x and cFP-RTD-12x provide double insulation
for up to 250 Vrms of operational isolation. You can safely use Compact
FieldPoint with the cFP-CB-1 or cFP-CB-3 connector block in applications
where hazardous voltages are present.
• 8 temperature inputs• Thermocouple or millivolt• 2, 3, or 4-wire RTD
• Built-in signal conditioningbetween channels• 250 V common-mode isolation
on TC-125• 50 and 60 Hz noise rejection
• 16-bit resolution• Input ranges configurable in software
for each channel• 2,300 Vrms bank isolation for transient
overvoltage protection• Hot-swappable with autoconfiguration• -40 to 70 °C operating range
NI cFP-TC-120, NI cFP-TC-125, NI cFP-RTD-122, NI cFP-RTD-124
ModuleInput
ChannelsResolution
(bits) Input TypeInput Ranges Software
Configurable per Channel50/60 Hz
Noise FilterAll-Channel
Update PeriodCommon-Mode
Between ChannelsSafety
IsolationcFP-TC-120 8 16 Thermocouple J,K,R,S,T,N,E, and B ± 25 mV, ±50 mV, 3 1.13 s (0.88 Hz) – 2,300 Vrms
bank isolation Millivolt ±100 mV, -20 to 80 mVcFP-TC-125 8 16 Thermocouple J,K,R,S,T,N,E, and B 3 0.22 s (Filter Off)
0.99 s (Filter On)250 Vrms 2,300 Vrms
bank isolation Millivolt -20 to 80 mVcFP-RTD-122 8 16 2, 3-Wire RTD Pt 100, Pt 1,000 3 1.08 s (0.93 Hz) – 2,300 Vrms
bank isolation Resistance 0 to 400, 0 to 4000 ΩcFP-RTD-124 8 16 2, 4-Wire RTD Pt 100 3 1.08 s (0.93 Hz) – 2,300 Vrms
bank isolation Resistance 0 to 400 Ω
Smart I/O ModulesThe cFP-TC-12x and cFP-RTD-12x modules offer 16-bit resolution for
high-accuracy measurements, and you can connect directly to industrial
sensors or units under test with the safety isolation available. The modules
filter, calibrate, and scale raw sensor signals to engineering units, as
well as perform self-diagnostics to look for problems such as open
thermocouples. With cFP-TC-12x and cFP-RTD-12x modules, your software
application reads a linearized, calibrated, scaled value from the I/O module,
eliminating the error-prone step of converting binary values to temperature.
For increased accuracy and noise rejection, the modules use a
16-bit delta-sigma ADC with an integrated lowpass filter on each
channel, which is configured for 50 and 60 Hz rejection. With high-accuracy
16-bit delta-sigma ADCs on the I/O modules, you also get instrument-quality
measurements on an industrially rugged, distributed, embedded system.
cFP-TC-12x and cFP-RTD-12x modules offer a variety of different update
rates to fit your application, ranging from 0.22 s with filters off and 1.08
to 1.13 s with filters enabled. Overall data throughput depends on filter
settings across all channels, software loop speeds, and network speeds.
cFP-TC-120The cFP-TC-120 includes eight differential inputs for thermocouples.
It also provides cold-junction compensation using a thermistor embedded
in the connector block. An onboard microcontroller compensates and
linearizes the thermocouple reading to the NIST IST-90 standard,
using an advanced linearization routine for maximum accuracy.
cFP-TC-125In addition to the thermistor and linearization features of the cFP-TC-120,
the cFP-TC-125 provides 250 Vrms of common-mode rejection, ideal for
applications where differences in voltages might exist between connected
thermocouples. The cFP-TC-125 also provides 0.22 s update rates when
the 50/60 Hz filter is not enabled.
cFP-RTD-122The cFP-RTD-122 includes eight inputs for 2 and 3-wire RTDs.
The module uses a stable current source for sensor excitation and an
onboard microcontroller that linearizes and scales the measurements to
temperature units. You can configure each channel of the module to
return data scaled to temperature (°C, °F, or °K) or resistance. The 3-wire
configuration used with the cFP-RTD-122 eliminates errors caused by
lead wire resistance but does not reduce errors caused by noise. If your
application involves high noise or long wires, you should use 4-wire RTDs
with the cFP-RTD-124.
cFP-RTD-124The cFP-RTD-124 includes eight inputs for 2 and 4-wire RTDs. The module
uses a stable current source for sensor excitation and an onboard
microcontroller that linearizes and scales the measurements to temperature
units. You can configure each channel of the modules to return data scaled
to temperature (°C, °F, or °K) or resistance. Four-wire RTDs used with the
cFP-RTD-124 are ideal for applications involving long signal wires or high
signal noise. The 4-wire configuration eliminates the voltage drop caused
by lead wire resistance and reduces errors caused by noise.
Isothermal Connectivity for the cFP-TC-12xFor maximum accuracy, NI recommends using an isothermal connector
block with the cFP-TC-12x. The cFP-CB-3 isothermal connector block
minimizes the temperature gradient across wiring connections,
improving the accuracy of the cold-junction measurement, and,
therefore, of thermocouple measurements.
Compact FieldPoint I/O ConnectionsCompact FieldPoint modules include a built-in power distribution bus
that provides multiple power connections on the module. A field-wired
power supply connected to the voltage (V) and common (C) terminals is
internally connected to a power distribution bus that provides additional
breakout terminals for voltage supply (VSUP) and common (COM). These
terminals offer a convenient way to distribute power to field devices that
require external power.
Each cFP-TC-12x input channel has two terminals for differential input:
1. Thermocouple positive input (IN+)
2. Thermocouple negative input (IN-)
Each cFP-RTD-122 input channel has three terminals:
1. Excitation output (EXCITE)
2. Sensing input (SENSE)
3. Common input (COM)
Each cFP-RTD-124 input channel has four terminals:
1. Excitation output (EXCITE)
2. Positive sensing input (SENSE+)
3. Negative sensing input (SENSE-)
4. Common input (COM)
Thermocouple and RTD Modules for Compact FieldPoint
2
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
Figure 1. Wiring Diagram for cFP-RTD-12x
Figure 2. Wiring Diagram for cFP-TC-120
Figure 3. Wiring Diagram for cFP-TC-125Note: Connections will depend on the application.
Thermocouple and RTD Modules for Compact FieldPoint
3
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
Ordering Information
NI cFP-TC-120 ......................................................................777318-120
NI cFP-TC-125 ......................................................................777318-125
NI cFP-RTD-122 ..................................................................777318-122
NI cFP-RTD-124 ..................................................................777318-124
Recommended System ProductsNI cFP-2120 ......................................................................777317-2120
NI cFP-1804 ..........................................................................779490-01
NI cFP-BP-4 ............................................................................778617-04
NI cFP-CB-1............................................................................778618-01
NI cFP-CB-3............................................................................778618-03
NI PS-5 Power Supply ..........................................................778805-90
BUY NOW!For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S.) or go to ni.com/advisors.
EX+ (Ch 0)
[c]FP-RTD-122
SENSE (Ch 0)
COM (Ch 0)
2-Wire RTD
ShortJumper
Wire
EX+ (Ch 1)
SENSE (Ch 1)
COM (Ch 1)
3-Wire RTD
EX+ (Ch 7)
SENSE (Ch 7)
COM (Ch 7)
4-Wire RTD
Leave this wire unconnected
SENSE+ (Ch 0)
[c]FP-RTD-124
SENSE– (Ch 0)
COM (Ch 0)
EXCITE+ (Ch 0)
2-Wire RTD
ShortJumper
Wire
ShortJumperWires
SENSE+ (Ch 1)
SENSE– (Ch 1)
COM (Ch 1)
EXCITE+ (Ch 1)
3-Wire RTD
SENSE+ (Ch 7)
SENSE– (Ch 7)
COM (Ch 7)
EXCITE+ (Ch 7)
4-Wire RTD
Thermocouple
[c]FP-TC-120
IN(–)
IN(+)
Shield
CV
To Next Channel
Thermocouple
cFP-TC-125
IN(–)
IN(+)
Shield
SpecificationsTypical for -40 to 70 °C unless otherwise noted.
Input CharacteristicsNumber of inputs ................................ 8ADC resolution .................................... 16 bits, 1 in 65,536Type of ADC ........................................ Delta-sigmaFilters................................................... 50/60 Hz rejectionExcitation current
cFP-RTD-122 ................................... 0.25 mAcFP-RTD-124 ................................... 2 mA
Data scaling optionscFP-TC-120...................................... Temperature (°C, °F, °K) or mVcFP-RTD-12x.................................... Temperature (°C, °F, °K)
or resistance (Ω)Update period, all channels
cFP-TC-125Filter off ...................................... 0.22 sFilter on ...................................... 0.99 s
cFP-TC-120...................................... 1.13 scFP-RTD-12x.................................... 1.08 s
Signal input bandwidthcFP-TC-120...................................... 3 HzcFP-TC-125...................................... 12 Hz
Cold-junction accuracy cFP-TC-12xWith cFP-CB-3 connector block...... 0.25 °C typ, 0.5 °C max
Input impedance (cFP-TC-12x) ............ 20 MΩInput current (cFP-TC-12x)................... 35 nA typ, 140 nA maxInput noise .......................................... ±1 LSBpp
Overvoltage protectioncFP-TC-120...................................... ±40 VcFP-TC-125...................................... ±250 V
Common-mode voltage between channels referencedto isolated ground
cFP-TC-125...................................... 250 VcFP-TC-120...................................... 1 VcFP-RTD-12x.................................... 2 V
Safety Isolation VoltageMaximum safety isolation voltage ..... 250 Vrms, Installation Category II
(cFP-TC-12x only)Channel-to-channel safety isolation... No isolation between channelsTransient overvoltage.......................... 2,300 Vrms
Physical CharacteristicsLED indicators
POWER (green) ............................... Power on and self-test passedREADY (green) ................................ Module configured and readyOPEN TC <0..7> (red)
(cFP-TC-12x)................................ Open or broken thermocoupleon channel
Dimensions.......................................... 128 by 88 by 25 mm(5.0 by 3.5 by 1.0 in.)
WeightcFP-TC-120...................................... 130 g (4.6 oz)cFP-TC-125...................................... 125 g (4.4 oz)cFP-RTD-12x.................................... 110 g (3.7 oz)
Power RequirementPower from network module
cFP-TC-120...................................... 350 mWcFP-TC-125...................................... 650 mW
EnvironmentalOperating temperature ....................... -40 to 70 °CStorage temperature........................... -55 to 85 °C
(cFP-TC-125 -40 to 80 °C)Relative humidity ................................ 10 to 90%, noncondensingMaximum altitude............................... 2,000 m; at higher altitudes
the isolation voltage ratingsmust be lowered
Pollution degree .................................. 2
Shock and VibrationOperating vibration, random
(IEC 60068-2-64) ............................. 10 to 500 Hz, 5 grms
Operating vibration, sinusoidal(IEC 60068-2-6) ............................... 10 to 500 Hz, 5 g
Operating shock(IEC 60068-2-27) ............................. 50 g, 3 ms half sine,
18 shocks at 6 orientations;30 g, 11 ms half sine,18 shocks at 6 orientations
Safety and Compliance
SafetyThis product is designed to meet the requirements of the followingstandards of safety for electrical equipment for measurement, control,and laboratory use:
• IEC 61010-1, EN 61010-1• UL 3121-1, UL 61010C-1• CAN/CSA C22.2 No. 1010.1
For UL, hazardous location, and other safety certifications, refer to theproduct label or to ni.com
Electromagnetic CompatibilityCE, C-Tick, and FCC Part 15 (Class A)Compliant Emissions........................... EN 55011 Class A at 10 m FCC
Part 15A above 1 GHz ImmunityEN 61326:1997 +A2:2001, Table 1
Note: For EMC compliance, you must operate this device withshielded cabling.
Thermocouple and RTD Modules for Compact FieldPoint
4
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
CE ComplianceThis product meets the essential requirements of applicable EuropeanDirectives, as amended for CE Marking, as follows:
Low-Voltage Directive (safety) ........... 73/23/EECElectromagnetic Compatibility
Directive (EMC)............................... 89/336/EEC
Refer to the Declaration of Conformity (DoC) for this product for any additionalregulatory compliance information. To obtain the DoC for this product,visit ni.com/certification and search by model number or product line.
Thermocouple and RTD Modules for Compact FieldPoint
5
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and CertificationNI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional ServicesOur Professional Services Team is composed of NI applications engineers,
NI Consulting Services, and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range from
start-up assistance to turnkey
system integration.
Visit ni.com/alliance.
OEM SupportWe offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Local Sales and Technical SupportIn offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation ServicesNI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Calibration Services NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
SERVICE NEEDS
© 2006 National Instruments Corporation. All rights reserved. FieldPoint, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
National Instruments • [email protected]
ni.com • (800) 813 3693 *351395A-01*351395A-01 2006-7533-161-101-D
Digital Input Modules for Compact FieldPoint and FieldPoint
OverviewThe National Instruments [c]FP-DI-3xx devices are versatile digital input
modules. The DI-300, DI-301, and DI-330 are available in the Compact
FieldPoint and FieldPoint product families. The new NI cFP-DI-304 module
is available for Compact FieldPoint systems. You can use these modules
to monitor digital signals ranging from low voltage levels up to 250 V.
They are commonly used to monitor proximity and limit switches,
pushbutton switches, thermostat outputs, relay closures, power circuits,
and TTL devices. All the modules include onboard diagnostics to ensure
trouble-free installation and maintenance.
Digital Input ModulesThe [c]FP-DI-3xx modules provide built-in module-to-module isolation to
protect your FieldPoint system and controller or communication interface
from high voltage levels. The DI-300, DI-301, and DI-304 modules use a
common ground plane for all the input channels. Each channel on the DI-300,
DI-301, and DI-304 modules include current-limiting circuitry to prevent
module damage when connected directly to a 24 VDC source. The DI-330
uses eight optically isolated input channels so that each digital input has
a separate ground plane, and you can use each channel with a different
voltage potential. Thus, you can connect one channel to a 5 VDC TTL signal
and another signal on the same DI-330 module to a 250 VAC line voltage.
Each channel on the DI-330 includes current-limiting circuitry that limits the
total current to 1.5 mA to prevent damaging the module. All channels on
the DI-3xx modules feature LEDs that indicate the input state of each
channel. The modules feature an all channel update rate of 1 kHz. Overall
data throughput depends on software loop speeds and network speeds.
IsolationThe [c]FP-DI-3xx modules feature bank isolation with 2,300 Vrms of
breakdown isolation. In addition, the DI-330 provides double insulation
for up to 250 Vrms of operational isolation. You can safely use Compact
FieldPoint in applications where hazardous voltages are present when
used with the cFP-CB-1 connector block. You can safely use FieldPoint in
applications where hazardous voltages are present with the FP-TB-x
terminal base. These Compact FieldPoint and FieldPoint modules do not
have channel-to-channel isolation.
Field I/O ConnectionsCompact FieldPoint and FieldPoint modules include a built-in power
distribution bus that provides multiple power connections on the module.
A field wired power supply connected to the voltage (V) and common (C)
terminals is internally connected to a power distribution bus that delivers
additional breakout terminals for voltage supply (VSUP) and common
(COM). These terminals offer a convenient way to distribute power
to field devices that require external power.
• 8,16, or 32 channel inputs• 24 VDC inputs• 4 to 250 VDC inputs• 15 to 250 VAC inputs (50/60 Hz AC)• 3 to 250 VAC inputs (1 kHz AC)
• 2,300 Vrms bank isolation for transientovervoltage protection
• Hot-swappable with autoconfiguration• -40 to 70 °C operating range
FieldPoint Software (included)• FieldPoint 5.0 (for all models)
NI [c]FP-DI-300, NI [c]FP-DI-301,NI cFP-DI-304, NI [c]FP-DI-330 NEW!
Module Input Channels Input Ranges Input Type Compatibility ExamplesSeparate Ground
Plane per ChannelAll ChannelUpdate Rate
AdditionalFeatures
[c]FP-DI-300 8 18 to 30 VDC Sinking 24 VDC sourcing devices – 1 kHz –
[c]FP-DI-301 16 18 to 30 VDC Sinking 24 VDC sourcing devices – 1 kHz –
cFP-DI-304 32 10 to 30 VDC Sinking 24 VDC sourcing devices – 1 kHz Hysteresis
[c]FP-DI-330 8 5 to 48 VDC5 to 250 VAC
Sinking or sourcing TTL, CMOS, 12 VDC, 24 VDC,48 VDC, 120/240 VAC/VDC
3 1 kHz Input current limiting(1.5 mA)
Digital Input Modules for Compact FieldPoint and FieldPoint
2
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
To next channel
[c]FP-DI-330
VSUP (Ch 0)
COM (Ch 0)
V C
+
–Input
Circuitry INB (Ch 0)
INA (Ch 0)Sinking-Output
Device with External
Power
VSUP (Ch 1)
COM (Ch 1)
INB (Ch 1)
INA (Ch 1)
VSUP (Ch 2)
COM (Ch 2)
INB (Ch 2)
INA (Ch 2)
InputCircuitry
InputCircuitry
+
–
Sourcing-Output
Device with External
Power
Sinking-OutputDevice
Powered by [c]FP-DI-330
VSUP (Ch 3)
COM (Ch 3)
INB (Ch 3)
INA (Ch 3)
InputCircuitry
Sourcing-OutputDevice
Powered by [c]FP-DI-330
VSUP (Ch n)
COM (Ch n)
INB (Ch n)
INA (Ch n)
InputCircuitry
+ –5-250 V ExternalPower Supply
SwitchTo next channel
[c]FP-DI-300/301/304
VIN (Ch 0)
VSUP (Ch 0)
COM (Ch 0)
V C
InputCircuitry
SourcingOutput
Device with External
Power
+
–
VIN (Ch 1)
VSUP (Ch 1)
COM (Ch 1)
InputCircuitry
SourcingOutputDevice
Powered by[c]FP-DI-30x
VIN (Ch n)
VSUP (Ch n)
COM (Ch n)
InputCircuitry
–
+15-30 VDC
External Power Supply
Switch
Wiring Schematics for the [c]FP-DI-3xx Modules
Ordering Information
Compact FieldPoint
NI cFP-DI-300 ......................................................................777318-300
NI cFP-DI-301 ......................................................................777318-301
NI cFP-DI-304 ......................................................................777318-304
NI cFP-DI-330 ......................................................................777318-330
Recommended Compact FieldPoint System Products
NI cFP-2120 ......................................................................777317-2120
NI cFP-BP-4 ............................................................................778617-04
NI cFP-BP-8 ............................................................................778617-08
NI cFP-CB-1............................................................................779618-01
NI PS-5 Power Supply ..........................................................778805-90
NI Developer Suite Professional Control Edition..................777906-03
FieldPoint
NI FP-DI-300 ........................................................................777518-300
NI FP-DI-301 ........................................................................777518-301
NI FP-DI-330 ........................................................................777518-330
Recommended FieldPoint System Products
NI FP-1601 ............................................................................777792-01
NI FP-TB-1..............................................................................777519-01
NI PS-4 Power Supply ..........................................................778586-90
NI Developer Suite Control Edition ......................................777905-03
BUY NOW!For complete product specifications, pricing, and accessory information, call (800) 813 3693 (U.S.) or go to ni.com.
Digital Input Modules for Compact FieldPoint and FieldPoint
3
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
SpecificationsTypical for -40 to 70 °C unless otherwise noted.
Digital Input Channels[c]FP-DI-300, [c]FP-DI-330 ...................................................... 8[c]FP-DI-301............................................................................ 16cFP-DI-304.............................................................................. 32
Input CharacteristicsInput impedance
[c]FP-DI-300, [c]FP-DI-301 .................................................. 5 kΩcFP-DI-304.......................................................................... 30 kΩ
Input current limiting [c]FP-DI-330......................................... 1.5 mA
Input Voltages[c]FP-DI-300, [c]FP-DI-301, cFP-DI-304................................... 0 to 30 VDC[c]FP-DI-330............................................................................ 0 to 250 VDC or 0 to 250 VAC (50/60 Hz AC) or 0 to 250 VAC (1 KHz AC)
Digital Logic Levels
Hysteresis (cFP-DI-304)Input voltage .......................................................................... 2 V minInput current........................................................................... 60 µA min
Isolation Voltage[c]FP-DI-30x
Channel-to-ground Continuous .................................................................... 250 Vrms
Withstand...................................................................... 2,300 Vrms, 5 s maxChannel-to-backplane
Continuous .................................................................... 250 Vrms
Withstand...................................................................... 2,300 Vrms, 5 s maxChannel-to-channel ........................................................... None
[c]FP-DI-330Maximum isolation voltage............................................... 250 Vrms, Installation Category II
Transient overvoltage ............................................................ 2,300 Vrms
Physical CharacteristicsLED indicators
Power (green) .................................................................... Power on and self-test passedReady (green)..................................................................... Module configured and ready<0..31>, <0..15>, or <0..7> (green) ....................................... Input state of each channel
Dimensions Compact FieldPoint............................................................ 2.4 by 12.7 by 6.6 cm (0.94 by 5 by 2.6 in.)FieldPoint (including terminal base).................................. 10.7 by 10.9 by 9.1 cm (4.2 by 4.3 by 3.6 in.)
WeightFP-DI-300/301.................................................................... 130 g (4.6 oz)cFP-DI-300/301 .................................................................. 100 g (3.6 oz)FP-DI-330 ........................................................................... 133 g (4.7 oz)cFP-DI-330.......................................................................... 103 g (3.7 oz)cFP-DI-304.......................................................................... 193 g (6.81 oz)
[c]FP-DI-300 [c]FP-DI-301 cFP-DI-304 [c]FP-DI-330
OFF State ON State OFF State ON State OFF State ON State OFF State ON State
Input Voltage (V) <5 >15 <5 >15 ≤5 ≥10 ≤1 VDC,≤1 VAC
≥4 VDC, ≥15 VAC (50/60 Hz AC),≥3 VAC (1 KHz AC)Input Current (µA) ≤1000 ≥3000 ≤1000 ≥3000 ≤150 ≥330
Digital Input Modules for Compact FieldPoint and FieldPoint
4
BUY ONLINE at ni.com or CALL (800) 813 3693 (U.S.)
Power Requirements (from Network Module)[c]FP-DI-300............................................................................ 185 mW[c]FP-DI-301............................................................................ 325 mW[c]FP-DI-330............................................................................ 200 mWcFP-DI-304.............................................................................. 1 W
EnvironmentOperating temperature .......................................................... -40 to 70 °CStorage temperature.............................................................. -55 to 85 °CRelative humidity ................................................................... 10 to 90%, noncondensing
Shock and VibrationThese specifications apply only to Compact FieldPoint. NI recommends Compact FieldPoint if your application is subject to shock and vibration.
Operating vibration, random (IEC 60068-2-64)...................... 10 to 500 Hz, 5 grms
Operating vibration, sinusoidal (IEC 60068-2-6).................... 10 to 500 Hz, 5 gOperating shock (IEC 60068-2-27) ......................................... 50 g, 3 ms half sine, 18 shocks at 6 orientations;
30 g, 11 ms half sine, 18 shocks at 6 orientations
SafetyThis product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use:
• IEC 61010-1, EN 61010-1• UL 61010-1• CAN/CSA-22.2 No. 61010-1
For UL, hazardous location, and other safety certifications, refer to the product label or to ni.com/certification.
Electromagnetic CompatibilityCE, C-Tick, and FCC Part 15 (Class A) Compliant
Emissions ........................................ EN 55011 Class A at 10 m; FCC Part 15A above 1 GHzImmunity ......................................... EN 61326:1997 + A2:2001, Table 1For EMC compliance, operate this device with shielded cabling.
CE ComplianceThis product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows:Low-Voltage Directive (safety)............ 73/23/EECElectromagnetic Compatibility
Directive (EMC) ............................... 89/336/EEC
Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification.
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and CertificationNI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional ServicesOur Professional Services Team is comprised of NI applications engineers,
NI Consulting Services, and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range from
start-up assistance to turnkey
system integration.
Visit ni.com/alliance.
OEM SupportWe offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
Local Sales and Technical SupportIn offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation ServicesNI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online with
ni.com/pxiadvisor.
Calibration Services NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
SERVICE NEEDS
© 2005 National Instruments Corporation. All rights reserved. FieldPoint, National Instruments, National Instruments Alliance Partner, NI, ni.com, NI Developer Suite, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI. 2005-6214-161-101
National Instruments • [email protected]
ni.com • (800) 813 3693
High-Speed Counter Modules for Compact FieldPoint and FieldPoint
Overview The National Instruments [c]FP-CTR-50x devices are versatile, high-
speed digital counter input modules for Compact FieldPoint and
FieldPoint that can be used to count digital signals ranging from 5 to
30 VDC and to measure frequency. These modules are fast enough to
handle input signals up to 50 kHz for high-speed applications, and
flexible enough to measure frequency using the internal frequency
reference or the external gate inputs. These powerful and versatile
counter modules feature configurable lowpass filters to eliminate
high-frequency noise and cascadable counter channels that can be
used to create counters up to 128 bits wide that will store trillions of
counts. For discrete control applications such as packaging, the
digital output channels can be configured to automatically energize
external devices.
All the modules include onboard diagnostics to ensure trouble-
free installation and maintenance.
Counter ModulesThe CTR-500 and CTR-502 counter modules include eight 16-bit,
50 kHz counters with dedicated clock inputs. For higher resolution
counting, you can combine counter channels to provide cascaded
counters of up to 128 bits. In addition, for each counter, you can set a
terminal count at which the counter automatically rolls over or resets.
For frequency measurement, you can configure each channel to use
any one of the four gate inputs provided. In this mode, you can
enable counting only when the state of the specified gate input is
logic high. By sending the digital pulse train to the gate input and
using the internal reference clock of 1 or 32 kHz, you can measure the
frequency of the incoming pulse train. Because you can read the state
of the gate input, you can also use the four gate inputs as general-
purpose digital input channels.
You can configure each of the four counter outputs to either pulse
or toggle states when you reach the terminal count for a counter
input. This is useful when you need to energize external equipment
upon reaching a particular count for applications like packaging.
You can also use each of the outputs as general-purpose digital outputs.
The CTR-500 modules work with 10 to 30 VDC sourcing devices and
provides sourcing outputs. A sourcing device is one that connects and
disconnect a voltage to the counter module. CTR-500 modules use a
common ground plane for all the digital input channels.
The CTR-502 modules work with 5 to 30 VDC sinking devices and
provides sinking outputs. A sinking device is one that connects and
disconnects a common to the counter module. CTR-502 modules use a
common ground plane for all the digital input channels.
All the channels on the digital input modules feature LEDs that
indicate the input state of each channel.
IsolationCTR-50x modules feature optical bank isolation with 2,300 Vrms of
breakdown isolation. These Compact FieldPoint and FieldPoint
modules do not have channel-to-channel isolation.
• 8 inputs• 5 to 30 VDC inputs • 16-bit counter registers• 50 kHz, maximum• Gate inputs and digital outputs• Cascadable counters for
higher counts• 2,300 Vrms bank isolation for
transient overvoltage protection • Hot swappable with
autoconfiguration • -40 to 70 °C operating range
NI [c]FP-CTR-500, NI [c]FP-CTR-502 NEW
Counter Internal Reference Clock MaximumModule Counter Inputs Input Ranges Inputs Type Resolution Gate Inputs Configurable Outputs for Frequency Measurements Input Frequency[c]FP-CTR-500 8 10 to 30 VDC Sourcing 16 bit, cascadable to 128 bit 4 4 1 and 32 kHz 50 kHz[c]FP-CTR-502 8 5 to 30 VDC Sinking 16 bit, cascadable to 128 bit 4 4 1 and 32 kHz 50 kHz
High-Speed Counter Modules for Compact FieldPoint and FieldPoint
2 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.com
Field I/O ConnectionsCompact FieldPoint and FieldPoint modules include a built-in
power distribution bus that provides multiple power connections on
the module. A field-wired power supply connected to the voltage (V)
and common (C) terminals is internally connected to a power
distribution bus that provides additional breakout terminals for
voltage supply (VSUP) and common (COM). These terminals provide
a convenient way to distribute power to field devices that require
external power.
The CTR-500 and CTR-502 have:
• 8 high speed digital counter input terminals (VIN)
• 4 digital gate input terminals (VIN)
• 4 digital output terminals (VOUT)
• 8 common terminals (COM)
• 8 power connections to power field devices (VSUP)
Compact FieldPoint NI cFP-CTR-500..........................................................777318-500NI cFP-CTR-502..........................................................777318-502
Recommended Compact FieldPoint System ProductsNI cFP-2020 ..............................................................777317-2020NI cFP-BP-4 ..................................................................778617-04NI cFP-CB-1 ..................................................................778618-01NI PS-5 power supply ..................................................778805-90NI Developer Suite Professional Control Edition..........777906-03
FieldPoint NI FP-CTR-500 ..........................................................777518-500NI FP-CTR-502 ..........................................................777518-502
Recommended FieldPoint System ProductsNI FP-1601 ....................................................................777792-01NI FP-TB-1 ....................................................................777519-01NI PS-4 power supply ..................................................778586-90NI Developer Suite Standard Control Edition ............777905-03
BUY ONLINE!Visit ni.com/info and enter cfpctr500, cfpctr502, fpctr500,and/or cfpftr502.
Ordering Information
To next channel
[c]FP-CTR-500
V C
+ –
COM (Count 0)
VSUP (Count 0)
VIN (Count 0)
10 – 30 VDC ExternalPowerSupply
InputCircuitry
Sourcing-Output Device
Powered by [c]FP-CTR-500
COM (Count 1)
VSUP (Count 1)
VIN (Count 1) InputCircuitry
Sourcing-OutputDevice
VOUT (Out 0)
VSUP (Out 0)
COM (Out 0)
COM (Gate 0)
VSUP (Gate 0)
VIN (Gate 0) InputCircuitry
Switch
Sinking-Input
Device
VOUT (Out 1)
VSUP (Out 1)
COM (Out 1)
Sinking-Input
Device
VOUT (Out 2)
VSUP (Out 2)
COM (Out 2)
Sinking-Input
Device
To next channel
[c]FP-CTR-502
V C
+ –
COM (Count 0)
VSUP (Count 0)
VIN (Count 0)
5 – 30 VDC ExternalPowerSupply
InputCircuitry
COM (Count 1)
VSUP (Count 1)
VIN (Count 1) InputCircuitry
Sinking-OutputDevice
VOUT (Out 0)
VSUP (Out 0)
COM (Out 0)
COM (Gate 0)
VSUP (Gate 0)
VIN (Gate 0) InputCircuitry
VOUT (Out 1)
VSUP (Out 1)
COM (Out 1)
VOUT (Out 2)
VSUP (Out 2)
COM (Out 2)
Sinking-Input
Device
Sinking-OutputDevice
Switch
Load
Powered Load
+
–
ExternalPowerSupply
Figure 1. Wiring Schemtatic for CTR Modules
High-Speed Counter Modules for Compact FieldPoint and FieldPoint
3National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.com
Typical for -40 to 70 °C unless otherwise noted.
Input CharacteristicsInput channels .................................................. 12 (8 count, 4 gate)Input type
[c]FP-CTR-500............................................. 10-30 VDC, sinking[c]FP-CTR-502............................................. 5-30 VDC, sourcing
Maximum input voltage ................................... 30 VDCInput threshold level
[c]FP-CTR-500............................................. 8 V typ6 V min10 V max
[c]FP-CTR-502............................................. VSUP – 2.5 V typVSUP – 3.0 V minVSUP – 2.0 V max(VSUP is the external supply voltage)
Input current limiting[c]FP-CTR-500............................................. 5 mA[c]FP-CTR-502............................................. 6 mA
Input bandwidthCount inputs .............................................. 50 kHz or software-enabled 200 kHz lowpass filterGate inputs ................................................ 50 kHz
Maximum off-state leakage current for external devices[c]FP-CTR-500............................................. 0.2 mA[c]FP-CTR-502............................................. 0.3 mA
Output CharacteristicsOutput channels ............................................... 4Output type
[c]FP-CTR-500............................................. 10-30 VDC sourcing, compatible with most 12 and 24 VDC devices
[c]FP-CTR-502............................................. 5-30 VDC sinking, compatible with TTL and other 5, 12, and 24 VDC devices
Supply voltage[c]FP-CTR-500............................................. 10-30 VDC, user-provided[c]FP-CTR-502............................................. 5-30 VDC, user-provided
Maximum output currentFP-CTR-500/502......................................... 1 A per channelcFP-CTR-500/502 ....................................... 1 A per channel at -40 to 50 °C;
0.75 A per channel at 50 to 60 °CMaximum output current on all channels........ 4 AOutput impedance
[c]FP-CTR-500............................................. 0.3 Ω[c]FP-CTR-502............................................. 0.12 Ω
Output bandwidth ............................................ 16 kHz for a current flow ≥3.2 mAMaximum off-state leakage current ................ 25 µA
Power RequirementPower from network module............................ 800 mW
Physical CharacteristicsLED indicators
POWER (green) .......................................... Power on and self-test passedREADY (green) ........................................... Module configured and ready
Count inputs <0..7> (green).............................. On/off state of counter inputGate inputs <0..3> (green)................................ On/off state of gate inputOutputs <0..3> (green)...................................... On/off state of outputDimensions (including terminal base).............. 10.7 by 10.9 by 9.1 cm (4.2 by 4.3 by 3.6 in.)Weight
FP-CTR-500/502......................................... 130 g (4.6 oz)cFP-CTR-500/502 ....................................... 100 g (3.5 oz)
Isolation VoltageMaximum isolation voltage ............................. 250 Vrms, Installation Category II Channel-to-channel isolation ........................... No isolation between channelsTransient overvoltage....................................... 2,300 Vrms
EnvironmentOperating temperature
FP-CTR-500/502......................................... -40 to 70 °CcFP-CTR-500/502 ....................................... -40 to 60 °C
Storage temperature ........................................ -55 to 85 °CRelative humidity ............................................. 10 to 90%, noncondensing
Shock and VibrationThese specifications apply only to Compact FieldPoint. NI recommends Compact FieldPoint if your application is subject to shock and vibration. Operating vibration, random
(IEC 60068-2-64) ........................................ 10 to 500 Hz, 5 grms
Operating vibration, sinusoidal (IEC 60068-2-6) .......................................... 10 to 500 Hz, 5 g
Operating shock (IEC 60068-2-27) ........................................ 50 g, 3 ms half sine, 18 shocks at 6 orientations;
30 g, 11 ms half sine, 18 shocks at 6 orientations
SafetyThis product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use:• IEC 61010-1, EN 61010-1• UL 3121-1, UL 61010C-1• CAN/CSA C22.2 No. 1010.1For UL, hazardous location, and other safety certifications, refer to the product label or to ni.com
Electromagnetic CompatibilityCE, C-Tick, and FCC Part 15 (Class A) CompliantEmissions.......................................................... EN 55011 Class A at 10 m FCC Part 15A above 1 GHzImmunity........................................................... EN 61326:1997 + A2:2001, Table 1For EMC compliance, operate this device with shielded cabling.
CE ComplianceThis product meets the essential requirements of applicable European Directives, as amended for CE Marking, as follows:Low-Voltage Directive (safety)......................... 73/23/EECElectromagnetic Compatibility
Directive (EMC).......................................... 89/336/EECRefer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/hardref.nsf/ and search by model number or product line.
Specifications
© 2003 National Instruments Corporation. All rights reserved. Product and company names listed are trademarks or trade names of their respective companies.
Global Services and SupportNI has the services and support to meet your needs around the globe
and through the application life cycle – from planning and
development through deployment and ongoing maintenance – and
tailored for customer requirements in research, design, validation, and
manufacturing. We have direct operations in more than 37 countries
and distributors in another 12 locations. Our local sales and support
representatives are degreed engineers, ready to partner with you to find
solutions that best fit your needs.
Local Sales and Technical SupportIn offices around the globe, our staff is local to the country so that
you have access to field engineers who speak your language and are
available to consult on your unique needs. We also have a worldwide
support organization staffed with Applications Engineers trained to
quickly provide superior technical assistance. Use our online Request
Support interface (ni.com/support) to define your question, then
speak to or e-mail an Applications Engineer, or access more than
14,000 worldwide measurement and automation professionals
within NI Developer Exchange Discussion Forums. ni.com/support
also provides immediate answers to your questions through self-help
troubleshooting, product reference, and application development
resources. For advanced technical support and software maintenance
services, sign up for Premier Support, a program that provides
expanded hours of support availability and
expedited phone/e-mail response time
(typically four business hours).
Training andCertificationNI recognizes that both initial
instruction and ongoing education
contribute to your success. NI provides a
variety of training alternatives, from self-
paced tutorials and interactive CDs, to worldwide
hands-on courses taught by experienced instructors – all designed so
that you can choose how to learn about our products. Further, NI offers
certifications acknowledging individual expertise in working with NI
products and technologies. Visit ni.com/training for more information.
Professional ServicesOur Professional Services team consists of National Instruments
Applications Engineers, NI Consulting Services, and the worldwide
National Instruments Alliance Partner Program (a network of 600
independent consultants and integrators). Our Professional Services
team can offer services ranging from basic start-up assistance and
collaborative development with
your engineers, to turnkey
system integration and
maintenance of your system.
In addition to our NI Alliance Partners, we have developed global
relationships with many industry partners that range from computer
software and hardware companies, such as Microsoft, Dell, Siemens,
and Tektronix. By collaborating with these companies, you receive a
complete spectrum of solutions – from components to turnkey
systems. Find the Alliance Partner directory at ni.com/alliance
Product ServicesNI hardware products are warranted against defects in workmanship
and material for one year from the date of shipment. To help you
meet project life-cycle requirements, NI offers extended warranties
for an additional charge. NI provides complete repair services for our
products. Express repair and advanced replacement services are also
available. Or, order your software and hardware installed in PXI and
PXI/SCXI™ systems with NI Factory Installation Services.
Ordering Made EasyVisit ni.com/products to browse product specifications, make
comparisons, or access technical representatives via online chat or
telephone. Worldwide customers can use a purchase order or credit
card to buy in local currency and receive direct shipments from local
NI offices. Our North American Customer Service Representatives
are available Monday through Friday between 7 a.m. and 7 p.m.
Central Time. Outside North America, please contact the NI office in
your country.
Order Status and Service RequestsNational Instruments brings you real-time status on current orders at
ni.com/status Similarly, find out the status of open technical support
incidents or hardware repair requests at ni.com/support/servicereq
CUSTOMER NEEDS
National Instruments • Tel: (512) 683-0100 • Fax: (512) 683-9300 • [email protected]
ni.com • (800) 433-3488
779463-01
778617-08
777584-01
777318-112
777318-550
777318-500
777318-122
cFP-1808, 8-slot Ethernet/Serial Interface for CompactFieldPoint
cFP-BP-8 8-Slot Backplane
PS-2 Power Supply (US 120 VAC) for FieldPoint Output:24VDC, 0.8A; Input: US 120 VAC
cFP-AI-112 16 ch, 16-Bit Analog Input Module (V)
cFP-DIO-550, Digital Input/Output Module (AC-DC sink/DCsource) 8 channel AC or DC Sinking Digital Input 8 channel DCSourcing Digital Output
cFP-CTR-500, Counter Input Module, 8 channel, externalpower supply optional.
cFP-RTD-122, 16 Bit RTD Input Module (RTD, Ohms), 8channel.
1
1
1
4
1
1
2
$ 999.00
$ 549.00
$ 79.00
$ 599.00
$ 279.00
$ 429.00
$ 469.00
$ 899.10
$ 494.10
$ 71.10
$ 2,156.40
$ 251.10
$ 386.10
$ 844.20
All sales are subject to the enclosed National Instruments terms and conditions of quotation and sale.National Instruments shall not be bound by any conflicting or additional Terms and Conditions. Standardshipping dates are based on product availability at time of quotation and are subject to change withoutnotice. Not all products produced by National Instruments are made in the U.S.A.
Freight Terms :Quote Valid Until :Payment Terms :
NI Weight Based Shipping28-JUN-07Net 30
Please indicate the above quote number when ordering for faster processing.
10%
10%
10%
10%
10%
10%
10%
Total : $ 5,152.98
Andrew NormanUniversity of VirginiaPhysics DepartmentCHARLOTTESVILLE, VA 22903
To ensure the highest quality service in order processing and support after delivery, please provide end-userinformation with your purchase order.
Estimated Delivery Days : 5 - 10 business days ARO.
Estimated Delivery Days : 5 - 10 business days ARO.
Estimated Delivery Days : 1 - 2 business days ARO.
Estimated Delivery Days : 1 - 2 business days ARO.
Estimated Delivery Days : 1 - 2 business days ARO.
Estimated Delivery Days : 1 - 2 business days ARO.
Estimated Delivery Days : 1 - 2 business days ARO.
Phone : 434 9825382
Fax :
National InstrumentsSales Office
11500 N Mopac ExpwyAustin, TX 78759-3504 U.S.A.
Tel : (512) 683-0100 Fax : (512) 683-5794Remit To : P.O. Box # 840909
Dallas, TX 75284-0909www.ni.com
Disc. %List Price Net PriceDescriptionPart NumberQty.Item
Currency quoted in : U. S. Dollars
1
2
3
4
5
6
7
Quotation Date : 05/29/2007
Quotation No. 928105
Shipping and Handling: $ 50.88
Yours sincerely,National Instruments Corporate
Andrew NormanUniversity of VirginiaPhysics DepartmentCHARLOTTESVILLE, VA 22903 Phone : 434 9825382
Fax :
National InstrumentsSales Office
11500 N Mopac ExpwyAustin, TX 78759-3504 U.S.A.
Tel : (512) 683-0100 Fax : (512) 683-5794Remit To : P.O. Box # 840909
Dallas, TX 75284-0909www.ni.com
Debbie Vasquez