new products digest...provide perfect modules from abundant products line-up! highly support various...
TRANSCRIPT
Provide perfect modules from abundant products line-up!Highly support various factory automation controls
■ Sensor connector(e-CON) type, MIL connector type I/O modules ■ Temperature control modules for CC-Link IE Filed Network■ Synchronous communication function compatible modules■ MELSEC-L Series RS-422/485 adapter module for GOT or other devices
NEWTemperature control module
NZ2GF2B-60TCTT4NZ2GF2B-60TCRT4
18-point two-piece terminal block type
NEW
NZ2GFCM1-16TNZ2GFCM1-16TE
MIL connector type
NZ2GFCE3-16TNZ2GFCE3-16TE
Sensor connector(e-CON) type
Transistor output module
NZ2GFCM1-16DNZ2GFCM1-16DE
MIL connector type
NZ2GFCE3-16DNZ2GFCE3-16DE
Sensor connector(e-CON) type
NEWDC input module
AvailableTransistor output module
NZ2GF2B1-16TNZ2GF2B1-16TE
18-point two-piece terminal block type
AvailableDC input module
NZ2GF2B1-16D18-point two-piece terminal block type
AvailableHigh-speed counter module
NZ2GFCF-D62PD240 pins connector type
Availableanalog I/O module
NZ2GF2B-60AD4NZ2GF2B-60DA4
18-point two-piece terminal block type
TOPICS
Synchronous communication function
NEW PRODUCTS DIGEST
February 2014
No.339E
New Product ReleaseDigest
NEW
NEW
Synchronous communication available
Synchronous communication available
Synchronous communication available
Synchronous communication available
NEW
NEW
NEW
• Response time can be set at 0ms, 0.2ms, 1ms, 1.5ms, 5ms, 10ms, 20ms and 70ms.• Enables a high-speed input/output control with the Fast logic function.
● Add and combine as you like! Flexible system configuration is possible with these block-type remote modules.● Connect an extension module to an I/O, analog, or high-speed counter module to extend the I/O points.● New type DC input modules and transistor output modules are now released.
These modules are compatible with sensor connector(e-CON) and MIL connector.Sensor connector(e-CON) type... Easy direct connection to a 2-wire or 3-wire sensor without a terminal module.MIL connector type ....... Easy connection for relay terminal and terminal conversion modules.
The simple connection method reduces a man-hour of the wiring work and the maintenance.● Two temperature control modules for CC-Link IE Field Network are also released.
These modules easily control and monitor the distributed temperature devices in the network.● The DC input, transistor output, analog I/O, and high-speed counter modules are compatible with the Synchronous
communication function.
CC-Link IE Field Network Block type remote modules
Model Input type Input points
Rated input voltage/current
Wiring method
Connect Extended
module
Synchronous communication
Connect Extended
module
Synchronous communication Model Output type Output
pointsRated load voltage/Max. load current
Wiring method
Available
Available
Available
Available
Available
Available
Available
DC input module
DC input 24VDC(6mA)16 points 1-wirePositive common
DC input 24VDC(4mA)16 points 3-wirePositive common
DC input 24VDC(4mA)16 points 1-wirePositive common
DC input 24VDC(4mA)16 points 3-wire
Negative common
Negative common
DC input 24VDC(4mA)16 points 1-wireNegative common
Sensor connector(e-CON) type
MIL connector type
18-point two-piece terminal block type
Remote device station
Remote device station
Remote device station
Remote device station
Remote device station
• The Number of ON times integration function easily accumulates the ON count of the connected output module.• Enables a high-speed input/output control with the Fast logic function.
Available
Available
Available
Available
Transistor output module
Transistor output 12/24VDC(0.5A)
12/24VDC(0.5A)
16 points 1-wireSink type
Transistor output Source type 16 points 1-wire
Transistor output 12/24VDC(0.5A)
12/24VDC(0.5A)
16 points 3-wireSink type
Transistor output Source type 16 points 3-wire
Transistor output 12/24VDC(0.5A)
12/24VDC(0.5A)
16 points 1-wireSink type
Transistor output Source type 16 points 1-wire
Sensor connector(e-CON) type
MIL connector type
18-point two-piece terminal block type
• Operates the counting speed of input pulse at 8Mpps max. The duty ratio of the PWM output function can be set by 0.1µs and this enables precise output control. • The Pulse measurement function with 100ns measurement resolution enables highly accurate pulse width measurement.
High-speed counter module
Synchronous communication function(Combination with simple motion module)
40 pins connector type
• Operates at the conversion speed of 400µs/channel(analog input module) and 100µs/channel(analog output module).• By connecting an extension DC input module to the analog input module, it enables more precise A/D conversion speed control.(with the Trigger conversion function)
Model Input/Output type Occupied station
Number of channels
Occupied station
Number of channels
Model Input/Output type
Model Input/output type Number of channels
Analog input/output module
Voltage/current analog input 1 station 4 channels
4 channelsVoltage/current analog output 1 station
18-point two-piece terminal block type
• Operates at the sampling cycle of 250 ms/4 channels. Mixed control mode of standard control and heating-cooling control is equipped. • The functions(Simultaneous temperature rise, Peak current suppression, Self-tuning, Heating-cooling control) are available.
Temperature control module
–
Available
Available
Available
–
–
Available
–
–
–
–
Available
Available
–
–
–
–
–
18-point two-piece terminal block type Thermocouple input, transistor output,
isolation between input channels
Resistance thermometer input, transistor output, isolation between input channels
1 station 4 channels
4 channels1 station
Differential input, DC input, coincidence output, transistor output(sink type) 2 channels
NZ2GF2B1-16D
NZ2GFCE3-16DE
NZ2GFCE3-16D
NZ2GFCM1-16D
NZ2GFCM1-16DE
NZ2GF2B1-16T
NZ2GFCE3-16T
NZ2GFCE3-16TE
NZ2GFCM1-16T
NZ2GFCM1-16TE
NZ2GF2B1-16TE
NZ2GF2B-60AD4
NZ2GFCF-D62PD2
NZ2GF2B-60DA4
NZ2GF2B-60TCTT4
NZ2GF2B-60TCRT4
CC-Link IE Field Network well supports various factory automation controls.
Mitsubishi Electric provides perfect modules from abundant products line-up.
Available
Available
Available
● DC input, transistor output, analog I/O, and high-speed counter modules are compatible with the Synchronous communication function. These modules perform with the operation cycle of the simple motion module. Therefore, the operation timing between the simple motion module(master station) and each slave station on the same network can be synchronized.
Connect Extended
module
Synchronous communication
Connect Extended
module
Synchronous communication
Connect Extended
moduleSynchronous
communication
*1: Simple motion module whose first 5-digit serial number is 15092 or later, supports this function. *2: I/O module whose first 5-digit serial number is 15102 or later, supports this function.
A slave module which supports the Synchronous communication function operates synchronously with the control cycle of the Simple motion module (the communication cycle of CC-Link IE Field Network). Therefore, the operation timing between the Simple motion module and each slave module can be synchronized.
Control cycle(Communication cycle)
2
1
3
4
5
NEW
NEW
NEW
compatible Incompatible
Simple motion moduleQD77GF16*1
Master station
Slave station Slave station
Transistor outputNZ2GF2B1-16T*2/16TE*2
DC inputNZ2GF2B1-16D*2
Servo amplifierMR-J4-B-RJ010+MR-J3-T10 Analog input
NZ2GF2B-60AD4*2
Analog outputNZ2GF2B-60DA4*2
High-speed counterNZ2GFCF-D62PD2*2
21
3
4
5
NEW
NEW
Synchronous communication available
Synchronous communication available
Synchronous communication available
Synchronous communication available
NEW
NEW
NEW
• Response time can be set at 0ms, 0.2ms, 1ms, 1.5ms, 5ms, 10ms, 20ms and 70ms.• Enables a high-speed input/output control with the Fast logic function.
● Add and combine as you like! Flexible system configuration is possible with these block-type remote modules.● Connect an extension module to an I/O, analog, or high-speed counter module to extend the I/O points.● New type DC input modules and transistor output modules are now released.
These modules are compatible with sensor connector(e-CON) and MIL connector.Sensor connector(e-CON) type... Easy direct connection to a 2-wire or 3-wire sensor without a terminal module.MIL connector type ....... Easy connection for relay terminal and terminal conversion modules.
The simple connection method reduces a man-hour of the wiring work and the maintenance.● Two temperature control modules for CC-Link IE Field Network are also released.
These modules easily control and monitor the distributed temperature devices in the network.● The DC input, transistor output, analog I/O, and high-speed counter modules are compatible with the Synchronous
communication function.
CC-Link IE Field Network Block type remote modules
Model Input type Input points
Rated input voltage/current
Wiring method
Connect Extended
module
Synchronous communication
Connect Extended
module
Synchronous communication Model Output type Output
pointsRated load voltage/Max. load current
Wiring method
Available
Available
Available
Available
Available
Available
Available
DC input module
DC input 24VDC(6mA)16 points 1-wirePositive common
DC input 24VDC(4mA)16 points 3-wirePositive common
DC input 24VDC(4mA)16 points 1-wirePositive common
DC input 24VDC(4mA)16 points 3-wire
Negative common
Negative common
DC input 24VDC(4mA)16 points 1-wireNegative common
Sensor connector(e-CON) type
MIL connector type
18-point two-piece terminal block type
Remote device station
Remote device station
Remote device station
Remote device station
Remote device station
• The Number of ON times integration function easily accumulates the ON count of the connected output module.• Enables a high-speed input/output control with the Fast logic function.
Available
Available
Available
Available
Transistor output module
Transistor output 12/24VDC(0.5A)
12/24VDC(0.5A)
16 points 1-wireSink type
Transistor output Source type 16 points 1-wire
Transistor output 12/24VDC(0.5A)
12/24VDC(0.5A)
16 points 3-wireSink type
Transistor output Source type 16 points 3-wire
Transistor output 12/24VDC(0.5A)
12/24VDC(0.5A)
16 points 1-wireSink type
Transistor output Source type 16 points 1-wire
Sensor connector(e-CON) type
MIL connector type
18-point two-piece terminal block type
• Operates the counting speed of input pulse at 8Mpps max. The duty ratio of the PWM output function can be set by 0.1µs and this enables precise output control. • The Pulse measurement function with 100ns measurement resolution enables highly accurate pulse width measurement.
High-speed counter module
Synchronous communication function(Combination with simple motion module)
40 pins connector type
• Operates at the conversion speed of 400µs/channel(analog input module) and 100µs/channel(analog output module).• By connecting an extension DC input module to the analog input module, it enables more precise A/D conversion speed control.(with the Trigger conversion function)
Model Input/Output type Occupied station
Number of channels
Occupied station
Number of channels
Model Input/Output type
Model Input/output type Number of channels
Analog input/output module
Voltage/current analog input 1 station 4 channels
4 channelsVoltage/current analog output 1 station
18-point two-piece terminal block type
• Operates at the sampling cycle of 250 ms/4 channels. Mixed control mode of standard control and heating-cooling control is equipped. • The functions(Simultaneous temperature rise, Peak current suppression, Self-tuning, Heating-cooling control) are available.
Temperature control module
–
Available
Available
Available
–
–
Available
–
–
–
–
Available
Available
–
–
–
–
–
18-point two-piece terminal block type Thermocouple input, transistor output,
isolation between input channels
Resistance thermometer input, transistor output, isolation between input channels
1 station 4 channels
4 channels1 station
Differential input, DC input, coincidence output, transistor output(sink type) 2 channels
NZ2GF2B1-16D
NZ2GFCE3-16DE
NZ2GFCE3-16D
NZ2GFCM1-16D
NZ2GFCM1-16DE
NZ2GF2B1-16T
NZ2GFCE3-16T
NZ2GFCE3-16TE
NZ2GFCM1-16T
NZ2GFCM1-16TE
NZ2GF2B1-16TE
NZ2GF2B-60AD4
NZ2GFCF-D62PD2
NZ2GF2B-60DA4
NZ2GF2B-60TCTT4
NZ2GF2B-60TCRT4
CC-Link IE Field Network well supports various factory automation controls.
Mitsubishi Electric provides perfect modules from abundant products line-up.
Available
Available
Available
● DC input, transistor output, analog I/O, and high-speed counter modules are compatible with the Synchronous communication function. These modules perform with the operation cycle of the simple motion module. Therefore, the operation timing between the simple motion module(master station) and each slave station on the same network can be synchronized.
Connect Extended
module
Synchronous communication
Connect Extended
module
Synchronous communication
Connect Extended
moduleSynchronous
communication
*1: Simple motion module whose first 5-digit serial number is 15092 or later, supports this function. *2: I/O module whose first 5-digit serial number is 15102 or later, supports this function.
A slave module which supports the Synchronous communication function operates synchronously with the control cycle of the Simple motion module (the communication cycle of CC-Link IE Field Network). Therefore, the operation timing between the Simple motion module and each slave module can be synchronized.
Control cycle(Communication cycle)
2
1
3
4
5
NEW
NEW
NEW
compatible Incompatible
Simple motion moduleQD77GF16*1
Master station
Slave station Slave station
Transistor outputNZ2GF2B1-16T*2/16TE*2
DC inputNZ2GF2B1-16D*2
Servo amplifierMR-J4-B-RJ010+MR-J3-T10 Analog input
NZ2GF2B-60AD4*2
Analog outputNZ2GF2B-60DA4*2
High-speed counterNZ2GFCF-D62PD2*2
21
3
4
5
HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANNAGOYA WORKS: 1-14, YADA-MINAMI 5, HIGASHI-KU, NAGOYA, JAPAN
For safe use• To use the products given in this publication properly, always read the relevant manuals before use.
• Ethernet is a registered trademark of Xerox Corporation in the United States.• All other company names and product names used in this document are trademarks or registered trademarks of their respective companies.
Country/Region Sales officeUSA ··················+1-847-478-2100Brazil·················+55-11-4689-3000Germany···········+49-2102-486-0UK·····················+44-1707-28-8780Italy ···················+39-039-60531Spain ················+34-93-565-3131France ··············+33-1-5568-5568
Czech Republic ····+420-251-551-470Poland ··············+48-12-630-47-00Russia···············+7-812-633-3497South Africa ······+27-11-977-0770China ················+86-21-2322-3030Taiwan ··············+886-2-2299-2499Korea················+82-2-3660-9530
Singapore ·········+65-6470-2308Thailand············+66-2906-3238Indonesia ··········+62-21-663-0833India··················+91-20-2710-2000Australia············+61-2-9684-7777
New publication, effective Feb. 2014.Specifications are subject to change without notice.1402(MDOC)
Related product catalog
Programmable ControllersMELSEC-L seriesL(NA)08159E
The new L series has a small footprint and is loaded with features.
Little on size, Large on performance
Programmable ControllersMELSEC-L series
Simple!
Ethernet-based Open NetworkCC-Link IE Product CatalogL(NA)08111E
CC-Link + Industrial Ethernet =CC-Link IE Field Network withMotion Functions
Ethernet-based Open NetworkCC-Link IE Product Catalog
Adapter module RS-422/485 adapter for MELSEC-L series
• Connection with GOT• Communication with target devices using the Predefined protocol function and the Serial communication function
L6ADP-R4 115.2kbpsCommunication
speed
GOT(Graphic Operation
Terminal)connectable
Predefined protocol
function
Serial communication
function
More and more MELSEC-L series products
NEW
New Product Release No.339E
CC-Link IE Field Network Block type remote modulesItem Model Outline
Remote I/O module
DC input
NZ2GF2B1-16D 16 points, 24VDC, Response time: 0 to 70ms, Positive/negative common shared, 18-point terminal block, 1-wire, Remote device station
NZ2GFCE3-16D*1*2 NEW16 points, 24VDC, Response time: 0 to 70ms, Positive common(sink type), Sensor connector(e-CON), 3-wire, Remote device station
NZ2GFCE3-16DE*1*2 NEW16 points, 24VDC, Response time: 0 to 70ms, Positive common(source type), Sensor connector(e-CON), 3-wire, Remote device station
NZ2GFCM1-16D*1 NEW16 points, 24VDC, Response time: 0 to 70ms, Negative common(sink type), MIL connector, 1-wire, Remote device station
NZ2GFCM1-16DE*1 NEW16 points, 24VDC, Response time: 0 to 70ms, Negative common(source type), MIL connector, 1-wire, Remote device station
Transistor output
NZ2GF2B1-16T 16 points, 12/24VDC(0.5A), Sink type, 18-point terminal block, 1-wire, Remote device station
NZ2GF2B1-16TE 16 points, 12/24VDC(0.5A), Source type, 18-point terminal block, 1-wire, Remote device station
NZ2GFCE3-16T*1*2 NEW 16 points, 12/24VDC(0.5A), Sink type, Sensor connector(e-CON), 3-wire, Remote device station
NZ2GFCE3-16TE*1*2 NEW 16 points, 12/24VDC(0.5A), Source type, Sensor connector(e-CON), 3-wire, Remote device station
NZ2GFCM1-16T*1 NEW 16 points, 12/24VDC(0.5A), Sink type, MIL connector, 1-wire, Remote device station
NZ2GFCM1-16TE*1 NEW 16 points, 12/24VDC(0.5A), Source type, MIL connector, 1-wire, Remote device station
Analog-digital converter module NZ2GF2B-60AD44 channels, Input: -10 to 10VDC, Output: DC0 to 20mA, Conversion speed: 400μs(1ms/ch), 18-point terminal block, Remote device station
Digital-analog converter module NZ2GF2B-60DA44 channels, Input: -10 to 10VDC, Output: DC0 to 20mA, Conversion speed: 400μs(1ms/ch), 18-point terminal block, Remote device station
Temperature control moduleNZ2GF2B-60TCTT4 NEW 4 channels, Thermocouple input, Transistor output, 18-point terminal block, Remote device station
NZ2GF2B-60TCRT4 NEW4 channels, Resistance temperature detector, Transistor output, 18-point terminal block, Remote device station
High-speed counter module NZ2GFCF-D62PD2
2channels[Differential input] Counting speed:10kpps/100kpps/200kpps/500kpps/1Mpps/2Mpps/4Mpps/8Mpps,
Count input signal:EIA Standard RS-422-A (Differential line driver)[DC input] Counting speed:10kpps/100kpps/200kpps, Count input signal:5/24VDC 4 to 8mA, Coincidence output:Transistor(sink type), 5 to 24VDC, 0.1A/point, 0.4A/common, 40 pin-connector
*1) A connector for Power supply and FG is required with e-CON and MIL connector type remote I/O module. Please refer to the product manual.*2) A sensor connector is required with e-CON connector type remote I/O module. Please refer to the product manual.
For further details, please refer to the relevant product manuals.