mci npp pump panel cat001 - tlp equipment
TRANSCRIPT
1-800-735-1097 | Fax: 972-247-8991 | www.motorcontrols.com
NOW AVAILABLE
OPTIONAL THREE PHASE PROTECTION SYMCOM 777 *MOTORONICS * FE SUBMONITOR
NPP—Series ACROSS-THE-LINE PUMP CONTROL PANELS
The NEMA Pump Panels are designed for the rugged
conditions required for the water systems industry. The
pump panel comes standard with Solid State overload
relays. Optional three phase protection modules are
available to upgrade the motor protection.
NEMA type 3R steel enclosure with powder coating finish
Full gasket hinged door with provision for padlocks
UL listed and suitable for use as service equipment
Heavy duty fusible or circuit breaker disconnect switch
NEMA full voltage magnetic motor starter
Solid state overload relay with selectable trip class that
provides phase loss and phase unbalance protection
Hand-Off-Auto selector switch
Start push button switch
Door mounted overload reset push button
Fuses ordered separately; 3 required
Features:
Catalog Number Explanation
1-800-735-1097 | Fax: 972-247-8991 | www.motorcontrols.com
NPP 4 4 FD SM Options
Nema Pump PanelVoltage
4 = 460 V 3P2 = 230 V 3PNema Size
Main DisconnectCB = Circuit Breaker
FD = Fused DisconnectSM = Submonitor OL
Options Code
SubMonitor - Door Mtd D
Surge Arrestor SA
White Pilot Light - Power On * WP
Green Pilot Light - Run * GP
Red Pilot Light - Off * RP
Yellow Pilot Light - Fault * YP
Control Xformer w/fuses
Size 1 & 2 XF2Size 3 & 4 XF4
Size 5 XF5ETM - Hour Meter * HMRestart Delay Timer* T124 Hr Prog Timer w/Skip-A-Day* T27 Day Time Clock w/Skip-A-Day* T3
* Options require control xformer
List Price
230$
330$
180$
180$
180$
180$
220$ 250$ 340$ 200$ 240$ 330$ 720$
Fused Disconnect Solid State Overload
Circuit Breaker Solid State Overload
1-800-735-1097 | Fax: 972-247-8991 | www.motorcontrols.com
MCI Part
number Max. HP
Input Voltage
NEMA Starter
SizeMax. Amps
Fused Disc. Size
Enclosure Size H x W x D Weight
List Price
NPP21FD 7 1/2 1 27 30 34" x 16" x 7" 40 $1,270
NPP22FD 15 2 45 60 34" x 16" x 7" 50 $1,460
NPP23FD 30 3 90 100 34" x 16" x 7" 111 $2,330
NPP24FD 50 4 135 200 45" x 16" x 9" 170 $3,450
NPP25FD 100 5 270 400 58" x 24" x 10" 440 $8,940
NPP41FD 10 1 27 30 34" x 16" x 7" 40 $1,270
NPP42FD 25 2 45 60 34" x 16" x 7" 50 $1,460
NPP43FD 50 3 90 100 34" x 16" x 7" 111 $2,330
NPP44FD 100 4 135 200 45" x 16" x 9" 170 $3,450
NPP45FD 200 5 270 400 58" x 24" x 10" 440 $8,940
NOTE: Fuses are not included
230
460
MCI Part
Number Max. HP
Input Voltage
NEMA Starter
SizeMax. Amps
Circuit Breaker
SizeEnclosure Size
H x W x D WeightList
Price
NPP21CB 7 1/2 1 27 30 34" x 16" x 7" 40 $1,770
NPP22CB 15 2 45 60 34" x 16" x 7" 50 $2,030
NPP23CB 30 3 90 100 34" x 16" x 7" 111 $2,860
NPP24CB 50 4 135 200 45" x 16" x 9" 170 $4,380
NPP25CB 100 5 270 400 58" x 24" x 10" 440 $10,750
NPP41CB 10 1 27 30 34" x 16" x 7" 40 $1,770
NPP42CB 25 2 45 60 34" x 16" x 7" 50 $2,030
NPP43CB 50 3 90 100 34" x 16" x 7" 111 $2,860
NPP44CB 100 4 135 200 45" x 16" x 9" 170 $4,380
NPP45CB 200 5 270 400 58" x 24" x 10" 440 $10,750
NOTE: when used on Open Delta systems could cause the solid state overload to trip!
230
460
Fused Disconnect Franklin Electric SubMonitor®
Circuit Breaker Franklin Electric SubMonitor®
1-800-735-1097 | Fax: 972-247-8991 | www.motorcontrols.com
MCI Part number
Max. HP
Input Voltage
NEMA Starter
SizeMax. Amps
Fused Disc. Size
Enclosure Size H x W x D Weight
List Price
NPP21FDSM 7 1/2 1 27 30 34" x 16" x 7" 40 $2,680
NPP22FDSM 15 2 45 60 34" x 16" x 7" 50 $2,950
NPP23FDSM 30 3 90 100 34" x 16" x 7" 111 $3,690
NPP24FDSM 50 4 135 200 45" x 16" x 9" 170 $4,810
NPP25FDSM 100 5 270 400 58" x 24" x 10" 440 $9,880
NPP41FDSM 10 1 27 30 34" x 16" x 7" 40 $2,680
NPP42FDSM 25 2 45 60 34" x 16" x 7" 50 $2,950
NPP43FDSM 50 3 90 100 34" x 16" x 7" 111 $3,690
NPP44FDSM 100 4 135 200 45" x 16" x 9" 170 $4,810
NPP45FDSM 200 5 270 400 58" x 24" x 10" 440 $9,880
NOTE: Fuses are not included
230
460
MCI Part Number
Max. HP
Input Voltage
NEMA Starter
SizeMax. Amps
Circuit Breaker
SizeEnclosure Size
H x W x D WeightList
Price
NPP21CBSM 7 1/2 1 27 30 34" x 16" x 7" 40 $3,280
NPP22CBSM 15 2 45 60 34" x 16" x 7" 50 $3,530
NPP23CBSM 30 3 90 100 34" x 16" x 7" 111 $4,270
NPP24CBSM 50 4 135 200 45" x 16" x 9" 170 $5,780
NPP25CBSM 100 5 270 400 58" x 24" x 10" 440 $11,980
NPP41CBSM 10 1 27 30 34" x 16" x 7" 40 $3,280
NPP42CBSM 25 2 45 60 34" x 16" x 7" 50 $3,530
NPP43CBSM 50 3 90 100 34" x 16" x 7" 111 $4,270
NPP44CBSM 100 4 135 200 45" x 16" x 9" 170 $5,780
NPP45CBSM 200 5 270 400 58" x 24" x 10" 440 $11,980
SubMonitor® equipped panels include the following: SubMonitor®, surge arrestor, alarm output & motor extended warranty for motors equipped with a subtrol sensor.
230
460
Schematic NPP with SUBMONITOR OVERLOAD PROTECTION
NPP with SOLID STATE OVERLOAD PROTECTION
1-800-735-1097 | Fax: 972-247-8991 | www.motorcontrols.com
Panel Sizes
1-800-735-1097 | Fax: 972-247-8991 | www.motorcontrols.com
A B C
34 16 7
45 20 9
58 24 10
NEMA Pump Panel Enclosure Dimensions Height Width Depth