low pim, high-power filter solutions for monitoring ... · wsd-00566 2060 2110 2170 2220 4000 -0.7...

7
Features: • Patent pending solution enables monitoring of PIM (Passive IM) up to 13 GHz, with high-power capabilities • Near end monitoring: carriers are rejected -90 dB by the notch filter and travel through the bandpass filter, into the low PIM termination • Far end monitoring: carriers are rejected -90 dB by the highpass filter (patent pending), whereas IM products permitted through are monitored by the spectrum analyzer • Test set capable to withstand 100 W CW and 1 KW peak Low PIM, High-Power Filter Solutions for Monitoring Broadband Emissions Low-PIM 50 ohm Termination Spurious Emission Broadband Emission P P I I M M W (Patent Pending) S/A SPn T SPn T BR3 BPn BR2 BP2 BR1 BP 1 Broadband PIM Monitoring General Concept for Low PIM ATE www.klmicrowave.com Phone: 410-749-2424 • FAX: 443-260-2268 Email: [email protected] www.klfilterwizard.com 2250 Northwood Drive Salisbury, MD 21804

Upload: tranquynh

Post on 26-Dec-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

◆ Features:

• Patent pending solution enables monitoring of PIM (Passive IM)

up to 13 GHz, with high-power capabilities

• Near end monitoring: carriers are rejected -90 dB by the notch filter

and travel through the bandpass filter, into the low PIM termination

• Far end monitoring: carriers are rejected -90 dB by the highpass

filter (patent pending), whereas IM products permitted through are

monitored by the spectrum analyzer

• Test set capable to withstand 100 W CW and 1 KW peak

Low PIM, High-Power Filter Solutions for Monitoring Broadband Emissions

Low-PIM 50 ohm Termination

Spurious Emission

Broadband Emission

PP II MMW(Patent Pending)

S/A

SPnT

SPnT

BR3

BPn

BR2

BP2

BR1

BP1

Broadband PIM Monitoring

General Concept forLow PIM ATE

w w w . k l m i c r o w a v e . c o mPhone: 410-749-2424 • FAX: 443-260-2268

Email: [email protected]

w w w . k l f i l t e r w i z a r d . c o m2250 Northwood DriveSalisbury, MD 21804

P/N F1MHz

F2MHz

F3MHz

F4MHz

F5MHz

BR- InsertionLoss (dB)

BP- InsertionLoss (dB)

WSD-00458 1790 1805 1880 1895 4000 -3 -3

WSD-00459 2095 2110 2170 2185 4000 -3 -3

WSD-00485 1915 1930 1990 2005 4000 -3 -3

WSD-00487 2095 2110 2155 2170 4000 -3 -3

WSD-00488 854 869 894 909 1650 -3 -3

WSD-00489 860 875 885 900 1650 -3 -3

WSD-00490 2605 2620 2690 2705 4000 -3 -3

WSD-00491 910 925 960 975 1650 -3 -3

WSD-00526 809 824 849 864 1650 -3 -3

WSD-00527 865 880 915 930 1650 -3 -3

WSD-00528 1695 1710 1785 1800 4000 -3 -3

WSD-00529 1835 1850 1910 1925 4000 -3 -3

WSD-00566 2060 2110 2170 2220 4000 -0.7 -1.5

WSD-00567 1880 1930 1990 2040 4000 -0.7 -1.5

WSD-00569 716 728 768 777 1400 -0.7 -1.5

WSD-00570 849 869 894 935 1650 -0.7 -1.5

WSD-00585 849 869 894 930 2000 -0.7 -1.5

WSD-00594* 2060 2110 2155 2205 4000 -0.7 -1.5

WSD-00599* 735 746 756 777 1400 -0.7 -1.5

WSD-00600 2570 2620 2690 2740 4000 -0.7 -1.5

WSD-00606 1910 1930 1990 2040 4000 -0.7 -1.5

WSD-00610 1910 1930 1990 2010 4000 -0.7 -1.5

WSD-00611 716 728 746 766 1400 -0.7 -1.5

WSD-00612 1463 1476 1511 1531 4000 -0.7 -1.5

WSD-00619 1463 1476 1486 1506 4000 -0.7 -1.5

WSD-00621 1785 1845 1880 1900 4000 -0.7 -1.5

WSD-00649 776 791 821 836 1400 -1 -1

WSD-00654 2280 2300 2400 2420 4000 -1.5 -1.5

WSD-00661 1520.5 1526 1555.25 1560.75 3000 -3 -3

BR- Return Loss: -10 dBrBP- Return Loss: -15 dBr

* -70 dB Rejection instead of -90 dB

Low PIM, High-Power Filter Solutions for Monitoring Broadband Emissions PP II MMW(Patent Pending)

The third product is measured at theBandreject port when two +43 dBmcarriers are present at the common portin the passband of the Bandpass filter.

PIM: The diplexers are available inthree PIM levels: -110 dBc (no dash),-130 dBc (-1) and -156 dBc(-2).

w w w . k l m i c r o w a v e . c o mPhone: 410-749-2424 • FAX: 443-260-2268

Email: [email protected]

w w w . k l f i l t e r w i z a r d . c o m2250 Northwood DriveSalisbury, MD 21804

Low PIM, High-Power Filter Solutions for Monitoring Broadband Emissions PP II MM(Patent Pending)

P/N F1MHz

F2MHz

F3MHz

F4MHz

F5MHz

BR- InsertionLoss (dB)

BP- InsertionLoss (dB)

WSD-00664 728 758 768 774 1400 -1 -1.5

WSD-00665 1915 1930 1995 2010 4000 -1.5 -1.5

WSD-00673 1915 1930 1990 2000 4000 -2 -1.5

WSD-00674 1795 1805 1880 1890 4000 -1.5 -1.5

WSD-00687 849 859 894 905 1650 -1.5 1.5

WSD-00691 1505 1525 1559 1579 3500 -1.5 -1.5

WSD-00692 852 862 869 893 1400 -1.5 -1.5

WSD-00694* 2570 2575 2615 2620 4000 -4.5 -4.5

WSD-00695* 2310 2320 2370 2380 4000 -3 -3

WSD-00709 2280 2300 2382 2402 4000 -2 -2

WSD-00713 2100 2130 2150 2180 4000 -1.5 -1.5

WSD-00732* 1875 1880 1915 1920 4000 -4 -4

WSD-00752 2486 2496 2690 2700 3800 -3.5 -5

WSD-00786 2483.5 2496 2690 2702.5 4000 -5 -5

WSD-00787 2610 2619 2691 2725 4000 -4 -4

WSD-00790 2090 2110 2170 2180 3800 -3 -3

WSD-00797 748 758 803 824 1500 -3 -3

BR- Return Loss: -10 dBrBP- Return Loss: -15 dBr

* - 75 dB Rejection for both BPF and BRF

WThe third product is measured at theBandreject port when two +43 dBmcarriers are present at the common portin the passband of the Bandpass filter.

PIM: The diplexers are available inthree PIM levels: -110 dBc (no dash),-130 dBc (-1) and -156 dBc(-2).

w w w . k l m i c r o w a v e . c o mPhone: 410-749-2424 • FAX: 443-260-2268

Email: [email protected]

w w w . k l f i l t e r w i z a r d . c o m2250 Northwood DriveSalisbury, MD 21804

Low PIM, High-Power Filter Solutions for Monitoring Broadband Emissions PP II MMW(Patent Pending)

◆ Bandpass/Bandstop Results

w w w . k l m i c r o w a v e . c o mPhone: 410-749-2424 • FAX: 443-260-2268

Email: [email protected]

w w w . k l f i l t e r w i z a r d . c o m2250 Northwood DriveSalisbury, MD 21804

P/N F1MHz

F2MHz

F3MHz

LP- InsertionLoss (dB)

LP- ReturnLoss (dBr)

HP- InsertionLoss (dB)

HP- ReturnLoss (dBr)

WSD-00568 960 1300 4000 -1.5 -15 -1 -10

WSD-00593 2700 4000 13000 -1.5 -15 -1 -10

WSD-00613* 2700 3000 6000 -1.5 -15 -1.5 -10

WSD-00618 2000 2400 6000 -1.5 -15 -0.7 -10

* -70 dB Rejection instead of -90 dB

Low PIM, High-Power Filter Solutions for Monitoring Broadband Emissions PP II MMW(Patent Pending)

◆ Highpass/Lowpass Examples

PIM: The diplexers are available inthree PIM levels: -100 dBc (no dash),-130 dBc (-1) and -156 dBc (-2).

The third IM product is measuredat the common port when two+43 dBm carriers are present atthe Lowpass port and/or theHighpass port, with an adjacentport terminated.

w w w . k l m i c r o w a v e . c o mPhone: 410-749-2424 • FAX: 443-260-2268

Email: [email protected]

w w w . k l f i l t e r w i z a r d . c o m2250 Northwood DriveSalisbury, MD 21804

Set-Up is self tested without the need forexpensive PIM Analyzer.

◆ PIM-Reflection Mode (1)

Low PIM, High-Power Filter Solutions for Monitoring Broadband Emissions PP II MM(Patent Pending)

Filters are self tested for PIM without theneed for an expensive PIM analyzer.

◆ PIM-Reflection Mode (2)

W

w w w . k l m i c r o w a v e . c o mPhone: 410-749-2424 • FAX: 443-260-2268

Email: [email protected]

w w w . k l f i l t e r w i z a r d . c o m2250 Northwood DriveSalisbury, MD 21804

◆ PIM-Through Mode (1)

Iso-Coupler

• Allows broadband sweeping of Tx signals• Amps need to provide 3 dB more gain• Tx Filter needs to reject IM products and be very clean

◆ PIM-Through Mode (2)

Iso-Diplexer

• Allows narrowband sweeping of Tx signals• Amps do not need to provide 3 dB more gain• Tx Filters are easier to make (narrower) only junction area is PIM sensitive.

Low PIM, High-Power Filter Solutions for Monitoring Broadband Emissions PP II MM(Patent Pending)W

w w w . k l m i c r o w a v e . c o mPhone: 410-749-2424 • FAX: 443-260-2268

Email: [email protected]

w w w . k l f i l t e r w i z a r d . c o m2250 Northwood DriveSalisbury, MD 21804