Laser Scan MicrometerNon-contact, high-speed, high-precision measurement
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
505
817
0
749070190
70min 420
Measuringrange
Center of (measuring point)70
200 12060
1590ø3.1
8-M3(Measuring position) 50
22
60100
1111 3
70 (C
ente
r of m
easu
ring
poin
t)
Cable space
25
15.5
10.5
567
35
70
SERIES 544 Laser Scan MicrometerLSM-902/6900
•Non-contact laser-based measuring system, mainly for outside diameter measurement. Suitable for delicate or moving workpieces.
•Accuracyof±0.5μmintheø0.1-ø25mmrange can be achieved. It is highly suitable suited for pin gage measurement.
•Narrowrangeaccuracyof±(0.3+0.1 D)μmfor high precision measurement.
•Ultra-highrepeatabilityof±0.05μm.•Thesystemconsistsofameasuringunit
(LSM-902)andadisplayunit(LSM-6900).
Optional Accessories (RefertopageG-44fordetails.)• Standardcalibrationgageset(ø1.0,ø25.0) : 02AGD180• Workstage : 02AGD270• Adjustableworkstage : 02AGD280• Digimaticcodeoutputunit(2-ch) : 02AGC840• 2ndI/Oanaloginterfaceunit : 02AGC880• BCD interface unit : 02AGC910• Printer&cableset(100V AC C-type plug) : 02AGD600A• Printer&cableset(120V AC C-type plug) : 02AGD600B• Printer&cableset(230V AC C-type plug) : 02AGD600C• PrintingpaperTP411-28CL/ 1Pack = 10pcs : 223663• Digimatic code output cable : 936937• Foot switch : 937179T
SPECIFICATIONSSetOrderNo. 544-494 544-495* 544-496*Measuring unitType mm mm inch/mmApplicablestandards JIS IEC,FDAMeasuring range 0.1to25mm(.004-1.0")Resolution 0.01to10μm(selectable)(.000001-.0005")Repeatability*1 ±0.05μm(±.000002")
Accuracy*2 (20°C)
Whole range ±0.5μm(±.000020")
Small range ±(0.3+0.1 D) [D:mm]*5
±(.000012+.001 D) [D:inch]Positional error*3 ±0.5μm(±.000020")Measuring range*4 ±1.5×25mm(±0.6x1.0")Scanning rate 800scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 56m/s(2240"/sec)Operatingenvironment
Temperature 0to40°CHumidity RH35to85%(nocondensation)
*1:Determinedbythevalueof±2 ( : standard deviation) whenmeasuringø25mmattheintervalof1.28sec.(average1024times).
*2:Atthecenterofthemeasuringrange.*3:Anerrorduetovariationinworkpiecepositioneitherinthe
opticalaxisdirectionorinthescanningdirection.*4:Theareagivenby[opticalaxisdirection]×[scanningdirection]*5: D=Difference in diameter between the master gage and
workpiece(Unit:mm)Note:TodenoteyourACpowercableaddthefollowingsuffixes
totheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredfor PSE.
Display unit
Display 16-digitplus11-digitfluorescentdisplay,andguidemessageLED
Segment 1to7(1to3,transparent)or1to255edgesAveragingtimes
Arithmeticaverage:per1to2048/Movingaverage:per32to2048
JudgmentSelectionfrom"targetvalue+tolerance","lowertolerance+uppertolerance",or"7classesmulti-limittolerancezone".
Measurement mode
Standby, Single measurement, Continuous measurement
Statistical analysis Maximum,Minimum,Average,Dispersion, (S.D)
Externaldimensions 335(W)×134(H)×250(D)mm
Power supply 100-240VAC±10%,50W,50/60HzStandardI/F RS-232C,AnalogI/O
OptionalI/F Digimaticcodeoutputunit(2-ch),2ndI/OanalogI/F,BCDI/F
Operatingenvironment 0to40°C,RH35to85%(nocondensation)
Others
Nominal setting, sample setting, selection of unnecessary digits,transparentobjectmeasurement,automaticmeasurement in edge mode, output timer, abnormal dataelimination,SHLchange,groupjudgment,simultaneous measurement, statistical processing, mastering, buzzer function, automatic workpiece detection(dimension/position),zero-set/offset*Measuringunitdualconnection,extra-finelinemeasurement,and some of the communication commands are not available.
Unit:mmMeasuring Unit External Dimensions
RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
G-42
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
Cable space
Measuring range
(Measuring position)
M3, depth 6 (×4)ø3.1, depth 6
55126181
2
1
34324610370min
2532
.5
8440
15.5
10.5 17.5
1111
Working distance
40
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-500S
•Capableofmeasuringdownto5μmoutsidediameter*1.
•Providesultra-highaccuracyof±0.3μmovertheentiremeasuringrange(5μmto2mm).
•Ultra-highspeedmeasurementof3200scan/sec.
Suitable for high speed lines or in applications subjecttovibration.
Optional Accessories• Multifunctional display unit, LSM-6200:
• Easy-to-operate display unit, LSM-5200:
•Standardcalibrationgageset(ø0.1,ø2.0) : 02AGD110• Guide pulley : 02AGD200•Airblower : 02AGD220
Unit:mmDIMENSIONS
RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.
OrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."
SPECIFICATIONSOrderNo. 544-531 544-532Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 0.005to2mm*1
Resolution 0.01to10μm(selectable)Repeatability*2 ±0.03μmAccuracy(20°C)*3 ±0.3μmPositional error*4 ±0.4μmMeasuring range*5 1×2mm(0.005to2mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 76m/sOperatingenvironment
Temperature 0to40°CHumidity RH35to85%(nocondensation)
ProtectionLevel IP64*6
*1:Themeasuringrangeforthetransparentobjectwillbe0.05mmto2mm.PleaseconsultyourlocalMitutoyoofficeforobjectssmallerthan0.05mm.
Themeasuringrangewillbe0.1mmto2mminthe1to255edgemeasurementmodeorwhenactivatingtheautomaticworkpiece detection.
IfusingtheoptionaldualconnectionunitforLSM-6200,themeasuringrangewillbe0.05mmto2mm.*2:Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø2mmattheintervalof0.32sec.(average1024times).*3:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*4: Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,theunitmaymalfunction.Note:Whenusingextra-finelinemeasurementfunction(FINE),guidemessagesforsettingthefollowingwillnotbedisplayed:dual-
measurement,segmentdesignation,automaticworkpiecedetection,andgroupjudgment.
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
G-43
G
Laser Scan MicrometerNon-contact, high-speed, high-precision measurement
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
8-M3
42 6453
10.5
15.5
2250
2084
104
57.5
23070min123 3968
34 34*7
10
48 8
18.5
4040
110 40.5 38.5 30
9.5
9.5
14.5
9.5
150
6
40 40
157 73
ø3.1 hole, depth 6(Measuring position)
Signal cable
Cable space
Relay cable
Emission Unit Base
Max. 100
Measuring range
Reception Unit
Measuring position
M4, depth 8 (×3) M4, depth 8 (×3)
To Reception Unit(Cable length 0.6m)
ø3.1 hole, depth 6
ø3.1 hole, depth 6
Dimension when disconnected (bottom view)
<Mass>Emission Unit: 0.7kgReception Unit: 0.4kgBase: 0.3kgSignal cable (5m): 0.5kg*7: Extendable up to 66mm.
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-501S
•Providesultra-highaccuracyof±0.5μmovertheentiremeasuringrange(0.05to10mm).
•Narrowrangeaccuracyof±(0.3+0.1 D)μmforhigh precision measurement.
•Ultra-highspeedmeasurementof3200scan/sec.
Suitable for high speed lines or in applications subjecttovibration.
Optional Accessories• Multifunctional display unit, LSM-6200:
• Easy-to-operate display unit, LSM-5200:
•Standardcalibrationgageset(ø0.1,ø10.0) : 02AGD120• Wire guiding pulley : 02AGD210•Adjustableworkstage : 02AGD400•Airblower : 02AGD230• Workstage : 02AGD270•Extensionsignalcable
SPECIFICATIONSOrderNo. 544-533 544-534Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 0.05to10mmResolution 0.01to10μm(selectable)Repeatability*1 ±0.04μm
Accuracy*2(20°C) Whole range ±0.5μmSmall range ±(0.3+0.1 D)μm*3
Positional error*4 ±0.5μmMeasuring range*5 2×10mm(ø0.05toø0.1mm)4×10mm(ø0.1toø10mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 113m/sOperatingenvironment
Temperature 0to40°CHumidity RH35to85%(nocondensation)
ProtectionLevel IP64*6
*1: Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø10mmattheintervalof0.32sec.(average1024times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4: Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Theprotectionlevelprovidedfortheinterior.Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,
the unit may malfunction.
Unit:mmDIMENSIONS
RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.
OrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m
•ExtensionrelaycableOrderNo. Cable length02AGC150A 1m
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."
G-44
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
ø3.1
8-M3
805.
5
10525054.584.5
42 42
70 min
170 5580 50*7
88
482594857202
6
18.5
5022
10.5
15.5
9.5
9.5
14.5
9.5
415790
12 11090
20
10
30
355
46
53 6842
95.5 65.5
150
57.5
130
(Measuring position)
Signal cable
Cable space
Relay cable
Emission Unit
Max. 350
Measuring range
Measuring range
Reception Unit
Base
M4, depth 8, ø3.3 through hole (×3)For mounting side plate (same in the back)
M4, depth 8, ø3.3 through hole (×2)For mounting side plate (same in the back)
To Reception Unit(Cable length 1.4m)
ø3.1, depth 6 (Reference hole)
M4, depth 8 (×3)For mounting base
ø3.1, depth 6 (Reference hole)
M4, depth 8 (×3)For mounting base
Dimension when disconnected (bottom view)
<Mass>Emission Unit: 1.1kgReception Unit: 0.6kgBase: 0.5kgSignal cable (5m): 0.5kg*7: Extendable up to 270mm
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-503S
•Ensures±1.0μmaccuracyovertheentiremeasuringrange(0.3to30mm).
•Narrowrangeaccuracyof±(0.6+0.1 D)μmforhigh precision measurement.
•Ultra-highspeedmeasurementof3200scan/sec.
Suitable for high speed lines or in applications subjecttovibration.
Optional Accessories• Multifunctional display unit, LSM-6200:
• Easy-to-operate display unit, LSM-5200:
•Standardcalibrationgageset(ø0.1,ø30.0) : 02AGD130•Adjustableworkstage : 02AGD490•Airblower : 02AGD240• Workstage : 02AGD270•Extensionsignalcable
Unit:mmDIMENSIONS
RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.
OrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m02AGN780D 20m
•ExtensionrelaycableOrderNo. Cable length02AGC150A 1m02AGC150B 3m02AGC150C 5m
SPECIFICATIONSOrderNo. 544-535 544-536Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 0.3to30mmResolution 0.02to100μm(selectable)Repeatability*1 ±0.11μmAccuracy*2
(20°C)Whole range ±1.0μmSmall range ±(0.6+0.1 D)μm*3
Positional error*4 ±1.5μmMeasuring range*5 10×30mm(0.3to30mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 226m/sOperatingenvironment
Temperature 0to40°CHumidity RH35to85%(nocondensation)
ProtectionLevel IP64*6
*1: Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø30mmattheintervalof0.32sec.(average1024times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4: Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Theprotectionlevelprovidedfortheinterior.Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,
the unit may malfunction.
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."
G-45
G
Laser Scan MicrometerNon-contact, high-speed, high-precision measurement
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
12-M3
ø3.1
15.5
10.5
110*716388
192348
66
20
60
42
4218
.5
90 360 90
2250
100
58 70
7
258 102
540
185 82
70min
2011
013
0
12
115.5 71
797
168.587 87
42
14.5
9.5
162 174.5 121 63
9.5
9.5
273
(Measuring position)
Signal cable
Cable space
Relay cable
Emission Unit
Max. 700
Measuring range
Measuring range
Reception Unit
Base
M5, depth 10, ø4.2 through hole (×3)For mounting side plate (same in the back)
M5, depth 10, ø4.2 through hole (×2)For mounting side plate (same in the back)
To Reception Unit(Cable length 1.4m)
ø3.1, depth 6 (Reference hole)
M5, depth 10 (×3)For mounting base
ø3.1, depth 6 (Reference hole)
M5, depth 10 (×3)For mounting base
Dimension when disconnected (bottom view)
<Mass>Emission Unit: 1.4kgReception Unit: 0.8kgBase: 0.8kgSignal cable (5m): 0.5kg*7: Extendable up to 537mm
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-506S
•Ensures±3μmaccuracyovertheentiremeasuringrange(1to60mm).
•Narrowrangeaccuracyof±(1.5+0.5 D)μminfor high precision measurement.
•Ultra-highspeedmeasurementof3200scan/sec. Suitable for high speed lines or in applications
subjecttovibration.
SPECIFICATIONSOrderNo. 544-537 544-538Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 1to60mmResolution 0.05to100μm(selectable)Repeatability*1 ±0.36μmAccuracy*2
(20°C)Whole range ±3μmSmall range ±(1.5+0.5 D)μm*3
Positional error*4 ±4μmMeasuring range*5 20×60mm(1to60mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 452m/sOperatingenvironment
Temperature 0to40°CHumidity RH35to85%(nocondensation)
ProtectionLevel IP64*6
*1: Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø60mmattheintervalof0.32sec.(average1024times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4: Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Theprotectionlevelprovidedfortheinterior.Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,
the unit may malfunction.
Unit:mmDIMENSIONS
RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.
Optional Accessories• Multifunctional display unit, LSM-6200:
• Easy-to-operate display unit, LSM-5200:
•Standardcalibrationgageset(ø1.0,ø60.0) : 02AGD140•Adjustableworkstage : 02AGD520•Airblower : 02AGD250•ExtensionsignalcableOrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m02AGN780D 20m
•ExtensionrelaycableOrderNo. Cable length02AGC150A 1m02AGC150B 3m02AGC150C 5m
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."
G-46
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
8-M4
ø3.1
312 88
48
7
48
146
9
146
9
200100
521379696 263
8068
18.5
4816
230
192
84
99131*7190
700107321272
238462
70 min
19
819
8
85144256192
198
150400150
120
30
(Measuring position)
Signal cable
Cable space
Relay cable
Emission Unit
Max. 700
Measuring range
Measuring range
Reception Unit
Base
M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)
M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)
M6, depth 12 (×3)For mounting base
M6, depth 12 (×3)For mounting base
To Reception Unit(Cable length 1.4m)
ø3.1, depth 6 (Reference hole)
ø3.1, depth 6 (Reference hole)
Dimension when disconnected (bottom view)
<Mass>Emission Unit: 3.0kgReception Unit: 1.2kgBase: 1.8kgSignal cable (5m): 0.5kg*7: Extendable up to 510mm
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-512S
•Ensures±6μmaccuracyovertheentiremeasuringrange(1to120mm).
•Narrowrangeaccuracyof±(4.0+0.5 D)μminfor high precision measurement.
•Ultra-highspeedmeasurementof3200scan/sec. Suitable for high speed lines or in applications
subjecttovibration.
Unit:mmDIMENSIONS
RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.
Optional Accessories• Multifunctional display unit, LSM-6200:
• Easy-to-operate display unit, LSM-5200:
•Standardcalibrationgageset(ø20.0,ø120.0) : 02AGD150•Airblower : 02AGD260•ExtensionsignalcableOrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m02AGN780D 20m
•ExtensionrelaycableOrderNo. Cable length02AGC150A 1m02AGC150B 3m02AGC150C 5m
SPECIFICATIONSOrderNo. 544-539 544-540Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 1to120mmResolution 0.1to100μm(selectable)Repeatability*1 ±0.85μmAccuracy*2 (20°C)
Whole range ±6μmSmall range ±(4.0+0.5 D)μm*3
Positional error*4 ±8μmMeasuring range*5 30×120mm(1to120mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 904m/sOperatingenvironment
Temperature 0to40°CHumidity RH35to85%(nocondensation)
ProtectionLevel IP64*6
*1: Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø120mmattheintervalof0.32sec.(average1024times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4: Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Theprotectionlevelprovidedfortheinterior.Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,
the unit may malfunction.
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."
G-47
G
Laser Scan MicrometerNon-contact, high-speed, high-precision measurement
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
ø3.1 (Measuring position)8-M4
84110 10
841
9 9
378
170 110600350 250
9
200100
120
100
7420
.5
880320 160400
8.7200 200
8.7
224
2524
9
206 87.5360520
306107100
40
200400 13 13688218
160
208
208
Min. 70
Cable space
Measuring range
M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)
M6, depth 12, ø5 through hole (×3)For mounting side plate (same in the back)
M6, depth 12 (×3)For mounting base
M6, depth 12 (×3)For mounting base
Measuring position ø3.1 hole, depth 6(Reference hole)
Note1: Distance between emission unit and reception unit: 400mm to 800mm
Note1
SERIES 544 Laser Scan Micrometer (Measuring Unit)LSM-516S
•Ensures±7μmaccuracyovertheentiremeasuringrange(1to160mm).
•Narrowrangeaccuracyof±(4.0+2.0 D)μmforhigh precision measurement.
•Ultra-highspeedmeasurementof3200scan/sec.
Suitable for high speed lines or in applications subjecttovibration.
SPECIFICATIONSOrderNo. 544-541 544-542Applicablelaserstandards JIS IEC,FDAUser'sManual Japanese version English versionMeasuring range 1to160mmResolution 0.1to100μm(selectable)Repeatability*1 ±1.4μmAccuracy*2 (20°C)
Whole range ±7μmSmall range ±(4.0+2.0 D)μm*3
Positional error*4 ±8μmMeasuring range*5 40×160mm(1to160mm)Scanning rate 3200scans/sLaserwavelength 650nm(Visible)Laserscanningspeed 1206m/sOperatingenvironment
Temperature 0to40°CHumidity RH35to85%(nocondensation)
ProtectionLevel IP64*6
*1: Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø160mmattheintervalof0.32sec.(average1024times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4: Anerroroftheoutsidediameterduetovariationincylinderpositioneitherintheopticalaxisdirectionorinthescanningdirection.*5:Theareagivenby[opticalaxisdirection]×[scanningdirection].*6:Theprotectionlevelprovidedfortheinterior.Iftheworkpieceorglassofthemeasuringunitwindowissoiledbywaterordust,
the unit may malfunction.
RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.
Optional Accessories• Multifunctional display unit, LSM-6200:
• Easy-to-operate display unit, LSM-5200:
•Standardcalibrationgageset(ø20,ø160) : 02AGM300•ExtensionsignalcableOrderNo. Cable length02AGN780A 5m02AGN780B 10m02AGN780C 15m02AGN780D 20m
•ExtensionrelaycableOrderNo. Cable length02AGC150A 1m02AGC150B 3m02AGC150C 5m
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
Unit:mmDIMENSIONS
OrderNo. Remarks544-046 Japanese user's manual544-047 English user's manual
OrderNo. Display type Remarks544-071 Japanesemm/E Japanese user's manual544-071* Englishmm/E English user's manual544-072* Englishmm/inch*TodenoteyourACpowercableaddthefollowing
suffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,FforSAA,KforKC,CandNosuffixarerequiredforPSE."
G-48
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
ø3.1 (Measuring position)
12-M3
Measuring range
80Ca
ble
spac
e18
0
11
25
60
98
1005022
647
60
120
1011 882365
52.540
382 85180
528
202
11
10.5
15.5
1010
0
10150
83 97
100 100
172 13.5
SERIES 544 Laser Scan Micrometer (Display Unit Integrated Model)LSM-9506
•Highaccuracyof±2.5μm,integrateddisplayunitwithmanyfunctionsequivalenttothemulti-functiondisplay unit.
Optional Accessories• Standardcalibrationgageset(ø1,ø60) : 02AGD170
Unit:mmDIMENSIONS
RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.
SPECIFICATIONSOrderNo. 544-115* 544-116**Type mm inch/mmMeasuring range 0.5to60mm .02”-2.36”/0.5-60mmResolution 0.05to100μm(selectable) .000002”-.005/0.00005-0.1mmRepeatability*1 ±0.6μm(±.00003")Accuracy*2(20°C) ±2.5μm(±.0001")Positional error*3
(opticalaxis/scanningdirection)±2.5μm(±.0001")
L:DisplacementbetweenworkpiececenterandopticalaxiscenterMeasuring range*4 ±5x60mm(±.2x2.36")Scanning rate 1600scans/sLaserwavelength 650nm(Visible)*5
Laserscanningspeed 226m/s(8900"/s)Display unit 16-digitdotmatrix(uppercolumn)+7segment11-digit(lowercolumn),guidanceLEDsStandard interface RS-232C,Digimaticcodeoutputunit(1ch)Optionalinterface NoPower supply AC100V-240V±10%,40VA,50/60HzOperatingenvironment 0to40°C,RH35to85%(nocondensation)*1:Determinedbythevalueof±2 ( :standarddeviation)whenmeasuringø10mmattheintervalof0.32sec. (average512times).*2:Centerofthemeasuringrangeforcylindricalworkpiecesoutsidediameter.*3: D=Differenceindiameterbetweenthemastergageandworkpiece(Unit:mm)*4:Anerroroftheoutsidediameterduetovariationinworkpiecepositioneitherintheopticalaxisdirectionorinthescanning
direction.*5:FDAClassII(544-116-1A)/IECClass2(Allmodelsexcept544-116-1A)semiconductorlaserforscanning(Maximumpower:1.0mW)*TodenoteyourACpowercableaddthefollowingsuffixestotheorderNo.:DforCEE,DCforCCC,EforBS,FforSAA,KforKC,
CandNosuffixarerequiredforPSE.**TodenoteyourACpowercableaddthefollowingsuffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,Kfor
KC,CandNosuffixarerequiredforPSE.
Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright, are attached to the Laser Scan Micrometers as isappropriate.
G-49
G
Laser Scan MicrometerNon-contact, high-speed, high-precision measurement
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
Cabl
e sp
ace
キーロック CAL オフセット 統計処理 同時測定
BUSYRUN+NGGO-NG
LD2 ON
LD1 ON 0 +/-
1 2 3
654
7 8 9
L.CAL
H.CAL
読込み
シフト 測定 設定
C
合否判定
基準値
入力単位
葦字
統計処理
PROG.
SW.FOOT
I/O ANALOG RS-232C REMOTE INTERLOCK
SCAN SIG.-1
TRANSMITTER-1
ID ROM 1
A1A6
B1B6DI
335
80
125
1313
428
1.4
121
13.5
250
12°
•2-axisdisplayunitenabless2itemsbedisplayedsimultaneously.
•Capableofstatisticalanalysissuchas:average,maximumvalue,minimumvalue,range(max.-min.).
•Segmentmeasurement(7points)oredgemeasurement(1to255edge)canbeselected.
•Afunctiontoeliminateabnormalvaluesisstandard.
•100tolerancevalues,presetvalues,orsettingscan be stored.
SERIES 544 Laser Scan Micrometer (Multifunctional Display Unit)LSM-6200
RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.
SPECIFICATIONSOrderNo. 544-071* 544-072*Type mm inch/mmDisplay 16-digitplus11-digitfluorescentdisplay,andguidemessageLEDSegment 1to7(1to3,transparent)or1to255edges*1
Averagingtimes Arithmeticaverage:per2to2048/Movingaverage:per32to2048(Arithmeticaverageisper16to2048when using 544-531, 544-532)
Judgment Selectionfrom"targetvalue+tolerance","lowertolerance+uppertolerance",or"7classesmulti-limittolerancezone".
Measurement mode Standby, Single measurement, Continuous measurementStatistical analysis Maximum,Minimum,Average,Dispersion, (S.D)Size 335(W)×134(H)×250(D)mmPower supply 100-240VAC±10%,40VA,50/60HzStandardI/F RS-232C,AnalogI/OOptionalI/F Digimaticcodeoutputunit(2-ch),2ndI/OanalogI/F,BCDI/FOperatingenvironment 0to+40°C,RH35to85%(nocondensation)
Others
Nominalsetting,samplesetting,selectionofunnecessarydigits,transparentobjectmeasurement*2, measurement of odd fluted parts, automatic measurement in edge mode, output timer, abnormal data
elimination,SHLchange,groupjudgment,simultaneousmeasurement,statisticalprocessing,mastering,buzzerfunction,automaticworkpiecedetection(dimension/position)*1,zero-set/offset,dualmeasurement(optional)
*1:Themeasuringrangewillbe0.1mmto2mminthe1to255edgemeasurementmodeorwhenactivatingtheautomaticworkpiece detection with 544-531, 544-532.
Each function has its combination limit.*2:Themeasuringrangeis50μmto2mmwhenusing544-531, 544-532. For smaller range, contact your local Mitutoyo sales office.*TodenoteyourACpowercableaddthefollowingsuffixestotheorderNo.:AforUL/CSA,DforCEE,DCforCCC,EforBS,Ffor
SAA,KforKC,CandNosuffixarerequiredforPSE.** Cannot be connected to 544-495, 544-496.** Previous models such as 544-451 cannot be connected.
Unit:mmDIMENSIONS
G-50
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
SERIES 544 Laser Scan Micrometer (Panel-mount Type Display Unit)LSM-5200
•Acompactcontrollerwhichcouldbeusedformulti-unit system configurations.
•CapableofsimpleconnectiontoaPCviaUSB.
•APanel-mounttypedisplayunitdesignedfortheLSM-Sseries.
•AnalogI/OandRS-232Cisstandard.•Measurement of odd fluted parts, and
simultaneousmeasurement/2-programfunctionareequipped.
138 0+1
72
144
140.4
68
138 (Aluminum case)
197.1 (20.5)
Front view
Rear view
68+0
.7 0
Dimensions of panel mounting slot (DIN 43 700-144×76)Panel thickness: 1.6mm to 6mmMass: 1.4kg
Support for mounting plate
Bottom view
Panel thickness: 1.6mm to 6mm
*240
.3 +
(t-
0.6)
(4.4
)
(Alum
inum
case
)
Side view
�
RefertotheLaserScanMicrometer(CatalogNo.E13004)formoredetails.
Unit:mmDIMENSIONS
SPECIFICATIONSOrderNo. 544-047Display 9digitsplus8digitsLED,guidemessageLEDSegment 1to7(1to3,transparent)or1to255edges*1
Averagingmethod Arithmeticaverage:from4to2048;Movingaverage:from32to2048(Arithmeticaverageisfrom16to2048whenusingLSM-500S.)
Judgment Selectingfrom"targetvalue±tolerancevalue"or"lowerlimit/upperlimit".Measurement mode Standby, Single measurement, Continuous measurementStatistical analysis CalculationresultisoutputviaUSBorRS-232C.Externaldimensions 144(W)×72(H)×197.1(D)mmPower supply*3 24VDC±10%,1.3AormoreStandardI/F USB2.0,RS-232C,I/OanalogOperatingenvironment 0to40°C,RH35to85%(nocondensation)
Preservation environments −20to70°C,RH35to85%(nocondensation)
Others
Measurement of odd fluted parts, simultaneous measurement, nominal setting, sample setting, selection of unnecessarydigits,transparentobjectmeasurement*2
Automaticworkpiecedetection(dimension/positiondetected)*1, abnormal data elimination, mastering, statistical processing(whenusingUSB,RS-232C),outputtimer,automaticmeasurementinedgemode,presetting
Note that every function is limited in its combination possibilities. See the user manual for details.Mass 1.4 kg
*1:Themeasuringrangewillbe0.1mmto2mminthe1to255edgemeasurementmodeorwhenactivatingtheautomaticworkpiece detection with 544-531, 544-532.
Each function has its combination limit.*2:Themeasuringrangeis50μmto2mmwhenusing544-531, 544-532. For smaller ranges, contact your local Mitutoyo sales office.*3:DC24Vexternalpowersupply(commercialitem)isrequiredseparately.Note 1: Cannot be connected to 544-495, 544-496.Note2:Previousmodelssuchas544-451 cannot be connected.Note3:ForUSBcommunicationwithaPC,adedicateddevicedriverisrequired.Fordetails,contactyourlocalMitutoyosalesoffice.
G-51
G
Laser Scan MicrometerNon-contact, high-speed, high-precision measurement
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefi t of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specifi cation without notice.
Sample Screen Measurement ExamplesPrinter roll multi-point simultaneous measurement
LSMPAK•SoftwarecanimportmeasurementdatafrommultipleLSM-5200displayunitstoaPCallowinga
variety of measuring systems to be constructed.•Capableofprocessingamaximumof10channelsofmeasurementdata(USB-HUBconnection).•CapableofCalculation between channels, statistical analysis, fi le output of calculation results.•Variousdisplayfunctionssuchascounterdisplay,graphdisplay,andcalculationresultareequipped. *RefertopageG-50forspecificationsofLSM-5200.
SERIES 544 Laser Scan Micrometer (Display Unit)Optional Accessories
544-047
544-531, 532
LSMPAK
Commercially available products, such as USB hubs and cables, areavailable for connecting to the display unit.
SPECIFICATIONSOrderNo. 02NGA002(English) 02NGA003(Korean) 02NGA004(German)
Applicablemodels Display unit: 544-047(Ver.1.004Aorlater)Measuring unit: 544-531, 532 series
Display function Max.12windows(counter,meter,chart,overalljudgment)
Setup function Presetting,dataoutput,samplemeasurement,resolutionselect,judgmentsetting,measurementofodd number fluted parts, simultaneous measurement *Each function has its combination limit.
Measurement function Single, continuous measurement, single automatic repetitionCalculation function Arithmeticoperation,maximum,minimum,range,average,total(anycombinationavailable)GO/NGjudgment 3-step(–NG,GO,+NG)Interface USB2.0(Hi-Speedcommunicationrecommended)Maximumconnection 10units
Operatingenvironment (PC)
OS WindowsXP,7(32-bit)CPU Pentium4,2GHzorbetterrecommendedMemory 1GB or moreHDD free space 500MBormoreDisplay 1024×768dot,TrueColor(32-bit)ormorerecommended
G-52
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
SERIES 544 Laser Scan Micrometer (Measuring Unit)Optional Accessories
•Standard cylinder gage set suitable for calibrationofLaserScanMicrometers.
•Nominalgagediameters(1to160mm)areasgiven in Specifications.
Standard calibration gage set
Installationexample(LSM-902)
•Easy set-up and height adjustmentenableshigh-precisionmeasurement.
Workstage
•Pin gage or plug gage•Rollerofcopyingmachine
Measurement Examples
•Vertical/horizontalslidemechanismenableseasymeasurement of various workpiece diameters.
•Bestsuitedforqualityassuranceofhighprecision pin gages.
Adjustable workstage
SPECIFICATIONSFor calibrating models 544-495, 544-496 544-531, 544-532 544-533, 544-534 544-535, 545-536 544-537, 544-538 544-539, 544-540 544-541, 544-542 544-115, 544-116Set No. 02AGD180 02AGD110 02AGD120 02AGD130 02AGD140 02AGD150 02AGM300 02AGD170
Configuration(OrderNo.)
Stand 02AGD181 02AGD111 02AGD121 02AGD131 02AGD141 02AGD151 02AGM320 02AGD171
Gages ø1:02AGD920ø25:02AGD963
ø0.1:958200ø2:958202
ø0.1:958200ø10:229317
ø1:02AGD920ø30:02AGD961
ø1:02AGD920ø60:02AGD962
ø20:229730ø120:234072
ø20:229730ø160:02AGM303
ø1:02AGD920ø60:02AGD962
Carrying case 02AGD190 958203 958203 02AGD980 02AGD980 02AGD990 02AGM310 02AGD970
SPECIFICATIONS
Model544-533, 544-534544-535, 544-536544-495, 544-496
OrderNo. 02AGD270
Basic configurationBasic set OrderNo. Model StandardAccessories Measuringrange(mm) Horizontalstroke(mm) Verticalstroke(mm)
(1)Mainunit(2)V-block(3)Stop
02AGD280 544-495, 544-496V-block(02AGD420),2pcsStopper(02AGD430),1pc
0.1-25 130 4702AGD400 544-533, 544-534 0.05-10 130 3202AGD490 544-535, 544-536 0.3-30 200 3502AGD520 544-537, 544-538 V-blockA(02AGD550),2pcs
V-blockB(02AGD560),1pcV-blockC(02AGD570),1pc
1-60 300 4502AGD370 544-115, 544-116 0.5-60 200 4502AGD680 0.5-60 300 45
* The stop is not included in the basic set for 544-537, 544-538, 544-115, 544-116. •Optionalpartfortheadjustableworkstage,suchascentersupport,adjustableV-block(up/down)etc.,areavailable.
Aninspectioncertificateissuppliedasstandard.RefertopageXfordetails.
G-53
G
Laser Scan MicrometerNon-contact, high-speed, high-precision measurement
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
SERIES 544 Laser Scan Micrometer (Measuring Unit)Optional Accessories
•Usedforsupportingmeasurementofoutsidediameter of fine wirelike materials such as magnetic wire or fiber.
Guide pulley
•Airblowsfromtheairoutletinstalledonthelasersection to clear dust adhering to the laser window.
Air shield
•Extensionsignalcablesarenecessarywhenthemeasuringunitanddisplayunitareseparatedinoperation;Extensionrelay cables are necessary when the optical section is separated in operation.
Extension signal cable / Extension relay cable
SPECIFICATIONSModel 544-531, 544-532 544-533, 544-534OrderNo. 02AGD200 02AGD210Each measurement range is as follows:544-531, 544-532:ø5μmtoø1.6mm544-533, 544-534:ø50μmtoø2mm
For calibration, the calibration gage set for 544-531, 544-532(02AGD110)isrequired.
SPECIFICATIONSAirsupplyunit Airshield Applicablemodels
957608
02AGD220 544-531, 544-53202AGD230 544-533, 544-53402AGD240 544-535, 544-53602AGD250 544-537, 544-53802AGD260 544-539, 544-540
*Airshieldissuppliedwith5mairtube(OutsideDiameter:6mm).
Extension signal cable
Relay cable, 1.4m(0.6m for 544-533, 544-534) Not equipped with 544-531, 544-532 (and 544-495, 544-496 )
Extension relay cable
Signal cable (5m) No.02AGN770A
Display unit
Emission Unit
Reception Unit
SPECIFICATIONSExtension signal cable Extension relay cableOrderNo. Cable length OrderNo. Cable length02AGN780A 5m 02AGC150A 1m02AGN780B 10m 02AGC150B 3m02AGN780C 15m 02AGC150C 5m02AGN780D 20m* For 544-531, 544-532 and 544-533, 544-534theallowablemaximumlengthforsignalcableis20m;relaycableis2m.* For 544-535, 544-536, 544-537, 544-538, 544-539, 544-540 and 544-541, 544-542theallowablemaximumlengthfor
signalcableis30m;relaycableis5m.*Themaximumextensionlengthofthesignalcableandrelaycableis32mintotal.* Cannot be used with 544-495, 544-496.
G-54
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
•Measurementdatacanbeprinted.
SERIES 544 Laser Scan Micrometer (Display Unit)Optional Accessories
Thermal printer DPU-414
•OutputsmeasurementdatainBCDoutput(7-digit)orHEXoutput.
•Datalogiccanbeswitched.•IsolatedI/Ocircuitry•Availablefor544-071, 544-072, 544-495,
544-496.
Interface for LSM6200, 6900Optional Accessories
BCD Interface
Foot switch
SPECIFICATIONS
OrderNo.
02AGD600A02AGD600B02AGD600C02AGD600D
Printing method ThermaldotmatrixPrinting capacity 40Columns(Normal)Character configuration 9×8dotmatrix
Printing direction BidirectionalInterface RS-232CPower supply AC100-240V50/60Hz(ACadapter)
StandardAccessories Printercable2m(02AGD620A), Printer paper1roll,ACadapter
Printerpaper(optional) OrderNo.223663(10-rollset)
•937179T•ForLSMOrder544-071, 544-072, 544-495,
544-496, 544-115, 544-116
SPECIFICATIONSOrderNo. 02AGC910StandardAccessories Connector(DDK)57-30360(214188)
G-55
G
Laser Scan MicrometerNon-contact, high-speed, high-precision measurement
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
XY Measurement
(X–Y): flatness(X+Y)/2:average*XYrequires10mm-interval.
Parallel Measurement
SERIES 544 Laser Scan Micrometer (Display Unit)Optional Accessories
•2-channelDigimaticcodeoutput•Insimultaneousmeasurement,measurement
data are output as follows:ProgramNo.0toNo.4inOUTPUT-1ProgramNo.5toNo.9inOUTPUT-2(10
programs operated)•10pinMILtypeconnector.•Outputcableisnotsupplied.Connectingcable(optional)1m(936937)•Availablefor544-071, 544-072, 544-495,
544-496.*Outputis6digitsofmeasurementdata.*Displaying6thand7thdigitafterthedecimalpointisnot
supported.
Digimatic code output unit
•Enables second unit connection to the 544-071, 544-072.(bothunitsmustbethesamemodel)
* Cannot be used for 544-495, 544-496.•Depending on the layout of the two measuring units,
large-diameter measurement, XY measurement, and parallel measurement are possible.
•Bothofthemeasuringunitsanddisplayunitscan be simultaneously operated.
120±10
47.8
200±10
Dual connection unit
•I/O,analogoutput.•Simultaneous measurement is supported by two
pairsofGO/NGjudgmentoutputs.•Availablefor544-071, 544-072, 544-495, 544-
496.
2nd I/O analog I/F
X Y
•BothBCD(02AGC910)and2ndI/OanalogI/F(02AGC880) can be mounted on 544-071, 544-072, 544-495, 544-496 using this cable.
* If using this cable, the dual connection unit (02AGP150) cannot be used.
Cable for BCD and 2nd I/O simultaneous mount
SPECIFICATIONSOrderNo. 02AGC840
SPECIFICATIONSOrderNo. 02AGP150
SPECIFICATIONSOrderNo. 02AGC880StandardAccessories Connector(DDK)57-30360(214188)
SPECIFICATIONSOrderNo. 02AGE060
Unit:mmDIMENSIONS
G-56
G
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
G-56
G
■ CompatibilityYourLaserScanMicrometerhasbeenadjustedtogetherwiththeIDUnit,whichissuppliedwiththemeasuringunit.TheIDUnit,whichhasthesamecode number and the same serial number as the measuring unit, must be installedinthedisplayunit.ThismeansthatiftheIDUnitisreplacedthemeasuring unit can be connected to another corresponding display unit.
■ The workpiece and measuring conditionsDepending on whether the laser is visible or invisible, the workpiece shape, and the surface roughness, measurement errors may result. If this is the case, perform calibration with a master workpiece which has dimensions, shape, and surface roughness similar to the actual workpiece to be measured. If measurement values show a large degree of dispersion due to the measuring conditions, increase the number of scans for averaging to improve the measurement accuracy.
■ Electrical interferenceTo avoid operational errors, do not route the signal cable and relay cable oftheLaserScanMicrometeralongsideahighvoltagelineorothercables capable of inducing noise current in nearby conductors. Ground all appropriate units and cable shields.
■ Connection to a computerIftheLaserScanMicrometeristobeconnectedtoanexternalpersonalcomputerviatheRS-232Cinterface,ensurethatthecableconnectionsconform to the specification.
■ Re assembly after removal from the baseObserve the following limits when re assembling the emission unit and reception unit to minimize measurement errors due tomisalignment of the laser's optical axis with the reception unit.
■ Laser safetyMitutoyoLaserScanMicrometersusealow-powervisiblelaserformeasurement.ThelaserisaCLASS2EN/IEC60825-1(2007)device.Warningandexplanationlabels,asshownright,areattachedtotheLaserScanMicrometers as is appropriate.
Laser Scan Micrometers Quick Guide to Precision Measuring Instruments
a. Parallel deviation between reference lines C and D: X(inthetransversedirection)
■ Alignment within the horizontal plane
b.AnglebetweenreferencelinesCandD:θx(angle)
c.ParalleldeviationbetweenreferenceplanesAandB:Y(inheight)
■ Alignment within the vertical plane
d.AnglebetweenreferenceplanesAandB:θy(angle)
ModelDistance between
Emission Unitand Reception Unit
X and Y θx and θy
544-533, 544-53468mm(2.68")orless within0.5mm(.02") within0.4˚(7mrad)100mm(3.94")orless within0.5mm(.02") within0.3˚(5.2mrad)
544-535, 544-536130mm(5.12")orless within1mm(.04") within0.4˚(7mrad)350mm(13.78")orless within1mm(.04") within0.16˚(2.8mrad)
544-537, 544-538273mm(10.75")orless within1mm(.04") within0.2˚(3.5mrad)700mm(27.56")orless within1mm(.04") within0.08˚(1.4mrad)
544-539, 544-540321mm(12.64")orless within1mm(.04") within0.18˚(3.6mrad)700mm(27.56")orless within1mm(.04") within0.08˚(1.4mrad)
544-541, 544-542 800mm(31.50")orless within1mm(.04") within0.05˚(1.6mrad)
l Allowable limits of optical axis misalignment
X
Reference line CReference line D
x
Reference line C
Reference line D
Y
Reference plane A
Reference plane B
y
Reference plane A
Reference plane B
G-57
Laser Scan MicrometerNon-contact, high-speed, high-precision measurement
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.Therefore the company reserves the right to change any or all aspects of any product specification without notice.
G-57
G
■ Measurement Examples
Diameter
Dia.
Out of roundness
Reference edge
Reference edge
Reference edge
Reference edge
Gap
In-line measurement of glass fiber or fine wire diameter
Measurement of outer diameter of cylinder
Measurement of outer diameter and roundness of cylinder
X- and Y-axis measurement of electric cables and fibers
Measurement of thickness of film and sheet
Measurement of spacing of IC chip leads
Measurement of film sheet thickness
Measurement of laser disk and magnetic disk head movement
Measurement of gap between rollers
Measurement of tape width
Measurement of outer diameter of optical connector and ferrule
Measurement of form
Dual system for measuring a large outside diameter