l t multi-network cable tester

24
10 BASE-T 3PK-NT007 AT&T 258A. TOKEN RING EIA/TIA568 MULTI-NETWORK CABLE TESTER BNC Indicator <Press To Test BNC Green-good GND ON OFF ON OFF Red-Bad Ounlit-Open Multi-Network Cable Tester 3PK-NT007 AT&T 258A. TOKEN RING EIA/TIA568 MULTI-NETWORK CABLE TESTER BNC Indicator <Press To Test BNC Green-good GND ON OFF ON OFF Red-Bad Ounlit-Open C A B L E T E S T E R M U L T I - N E T W O R K Network Cable Terminator 1&2 3&6 4&5 7&8 -GND Good Pe Mix or No Light-Fauity pt 108aset Token Ring 258A EIA TIA 568 USER'S MANUAL 3PK-NT005 3PK-NT007 3PK-NT008 1 2 3 4 5 6 7 8 G B CABLE TESTER MASTER OFF ON S MT-7051 RJ45 + RJ11 MT-7051

Upload: others

Post on 23-Mar-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

10 BASE-T

3PK-NT007

AT&T 258A. TOKEN RING EIA/TIA568

MULTI-NETWORK

CABLE TESTERBNC Indicator

<Press To Test BNCGreen-good

GNDONOFF

ONOFF

Red-BadOunlit-Open

Multi-Network Cable Tester

3PK-NT007

AT&T 258A.TO

KEN RING

EIA/T

IA568

MULTI-N

ETWORK

CABLE TE

STER

BNC Indica

tor

<Press

To Te

st BNC

Green-g

oodGND

ONOFF

ONOFF

Red-Bad

Ounlit-O

pen

CA

B L E T E S TE R

MULT

I -N ETW O

RK

NetworkCable

Terminator

1&2

3&6

4&5

7&8

-GND

Good Pe Mix or NoLight-Fauity pt108asetTokenRing258AEIA TIA568 USER'S MANUAL

3PK-NT0053PK-NT0073PK-NT008

1

2

34

5

67

8G

B

CABLE

TESTER

MASTER

OFF ON S

MT-7051

RJ45 + RJ11

MT-7051

INDEX

Thank you for purchasingthe multi-network cable tester

The multi-network cable is widely use for network testing. The multi-network cable tester can automatically check for continuity, shorted, open and crossed wire pairs. Before use the multi-network cable tester, please read the following instructions completely.

MT-7051MULTI- MODULAR CABLE TESTER.............................3

3PK-NT005MULTI- MODULAR CABLE TESTER.............................5

3PK-NT007MULTI-NETWORK CABLE TESTER.............................7

3PK-NT008ENHANCED NETWORK CABLE TESTER....................9

1

INTRODUCTION

These cable testers are specialized to quickly test by auto scanning for wires continuity, misswiring and polarization of thin Ethernet (BNC/TNC), 10-Base-T (UTP/STP), AT&T 258A, TIA568A/B, Token Ring and USOC4/6/8 modular cable. By using the attached remote terminator, you can easily test a cable whatever before or after the cables are installed. Easy access and quick check up.

PR1

PR2

Ethernet 10Base-T

PR2

PR3 PR4PR1

EIA/TIA-568A

PR3

PR2 PR4PR1

EIA/TIA-568BAT & T 258A

PR2

PR1

8-positionToken Ring

BNCPlug

BNC Jack 1 2 3 4 5 6 78

PR3

PR2

PR1

USOC 8

1 2 3 4 5 6

PR3

PR2

PR1

USOC 4 (Prs. 1 &2)USOC 6 (Prs 1,2 &3 )

2

1

2

3

4

5

6

7

8

G

B

CABLETESTER

MASTER

OFF ON S

MT-7051

RJ45 + RJ11

1

2

3

4

5

6

7

8

G

REMOTEMT-7051

RJ11 + RJ45

RemoteTerminator

RemoteTerminator

Master

MT-7051

3

Remarks:Please make sure-a 9-volt alkaline battery has been installed in the battery compartment.

Caution:Don't connect cable tester to the live circuits as it may be damaged by over voltage.

MT-7051MULTI-MODULAR CABLE TESTER Warning:

1. For protect and safety reasons, please don't use MT-7051 test AC power.

2. Turn on MT-7051, the power light is dark or not light. Please replace new 9V battery.

How to Use MT-7051:1. Turn on power switch, the power light will be flash.( "S" for low

speed test )2. To test twist pair cable, one side contect to the master unit and

the other side contect to remote unit. 3. On main unit indicator light from No.1 to 8. If the cable is

normal, the indicator light will be light from No.1 to 8. 4. To test coaxial cable, connect one end of the coaxial cable to the

connector on the main unit and connect a terminator to the other end of the cable. If the cable is good, the MT-7051 indicator light "B" on the main unit shines green. If the light does not shine, the cable has an open connection or short.

4

MU

LTI-MO

DU

LAR

CA

BLE TESTER

POW

ER

USO

C

ON

OFF

1&8

2&7

3&6

4&5

4P4C6P6C

8P8C

ALL G

REEN- O

K- STRA

IGH

TWIRED

ALL RED

- OK

MIX O

R NO

LIGH

T - M

ISWIRED

- CROSSW

IRED

Modular

CableTerm

inator

RJ12RJ11

RJ45U

SOC

Good LightStraight w

ire

Crosswire

Red Light

Mix or no light 1827

1 4

2 3

3645

162534

Misw

ire

Rem

oteTerm

inatorM

aster

3PK-N

T005

MU

LTI-MO

DU

LAR

CA

BLE TESTER

POW

ER

USO

C

ON

OFF

1&8

2&7

3&6

4&5

4P4C6P6C

8P8C

ALL G

REEN- O

K- STRA

IGH

TWIRED

ALL RED

- OK

MIX O

R NO

LIGH

T - M

ISWIRED

- CROSSW

IRED

3PK-N

T005

3PK-NT005

5

Remarks:Please make sure a 9-volt alkaline battery has been installed in the battery compartment.

Caution:Don't connect cable tester to the live circuits as it may be damaged by over voltage.

Test for USOC 4/USOC 6/USOC 8 Modular Cable 1. Plug one end to the master tester and the other end to the remote

terminator (you may plug boths end to master unit only, if you are not doing a remote test).

2. Push the power switch on, the power LED will flash to show the power is working properly.

3. As soon as the tested cable is inserted the LEDs on the remote terminator will start to scan one by one.

4. If the tested cable is OK, the corresponding pair of LEDs will light up all Green.

5. If the corresponding pair of LEDs is lighted all RED, the cable was wired reversely.

6. If the LEDs light up GREEN first and Red after (mix) or it is unlighted, the cable is bad.

3PK-NT005MULTI- MODULAR CABLE TESTER

6

3PK-NT007

NetworkCable

Terminator

1&2

3&6

4&5

7&8

-GNDGood Pe

Light-Fauity pr108asetToken Ring 258A EIA TIA568

10BASE-TAT&T 258A.

TOKEN RING EIA/TIA568

MULTI-NETWORKCABLE TESTER

Green-good

GND

POWER

ON OFF ON OFF

Red-Bad Ounlit-Open

BNC Indicator<Press To Test BNC

Mix or No

RemoteTerminator

RemoteTerminator

Master

3PK-NT007

7

Test for Coaxial Cable (BNC)1.Plug one end to the BNC socket of the master unit and the other

end to the remote terminator.2.Push the power switch on, the power LED will flash to show the

power is working properly.3.After the cable is inserted, the BNC LED should be kept

unlighted. If the BNC LED is lighted up, then the cable is bad.4.Push the button which is on the left side of the master unit . The

BNC LED indicator will light up GREEN if the cable is OK. If LED lights up RED or no light, the cable is bad.

Test for 10-Base-T, AT& T 258A, EIA/TIA 568, Token Ring Cable 1.Plug on end of the cable to the jack of the master unit and the

other end to the remote terminator.2.Push the power switch on , the power LED will flash to show the

power is working properly. 3.As soon as the power was switched on, the LEDs on the remote

terminator will start to scan one by one. If the cable is OK, the LEDs corresponding to each pair connected will light GREEN. If the LED is lighted GREEN first and RED after (mix) or it is unlighted, the cable is bad .

4. If the cable is shielded, you may test shielding by pushing the GND switch on The corresponding LEDs and GND LED will light up with all green except the LED of pair 3 & 6 is kept off . If any LED is lighted green first and red after or unlighted, it's showing the shielding is bad.

3PK-NT007MULTI-NETWORK CABLE TESTER

8

Enh

anced

Netw

ork

Cab

le Tester

GREEN

LIGH

T-GO

OD

PAIR

MIX O

R NO

LIGH

T-FAU

LTY PAIR

1&2

ON

OFF

ON

OFF

3&6

4&5

7&8

GN

DPO

WER

10BASE - T

TOKEN

RING

AT&T 258A

EIA/TIA 568

Enh

anced

Netw

ork

Cab

le Tester

GREEN

LIGH

T-GO

OD

PAIR

MIX O

R NO

LIGH

T-FAU

LTY PAIR

1&2

ON

OFF

ON

OFF

3&6

4&5

7&8

GN

DPO

WER

10BASE - T

TOKEN

RING

AT&T 2558A

EIA/TIA 568

Netw

orkCable

Terminator

1&2

3&6

4&5

7&8-G

ND

Good Pr.

Mix or N

oLight-Fauity pt108asetTokenRing258AEIA TIA

568

Rem

oteTerm

inatorM

aster

3PK-N

T008

3PK-NT008

9

Remarks: 1. Please make sure a 9-volt alkaline battery has been installed in

the battery compartment. 2. Remember to always keep the GND switch off, if you are not

testing the shielding.

Caution:Don't connect cable tester to the live circuits as it may be damaged by over voltage.

Test for 10-Base-T, AT&T 258A, EIA/TIA 568 and Token Ring Cable

1. Plug one end to the marked ▲ jack of the master unit and the other end to the remote terminator (you may plug both ends to the master unit only, if you are not doing a remote test).

2. Push the power switch on, the power LED will flash to show the power is working properly.

3. As soon as the power is switched on, the LEDs on the remote terminator will start to scan one by one.

4. If the cable is OK, the LEDs corresponding to each pair connected will light GREEN . If the LED is lighted GREEN first and RED after (mix.) or it is unlighted, the cable is bad.

5. If the cable is shielded , you may test shielding by pushing the GND switch on. The corresponding LEDs and GND LED will light up with all green except the LED of pair 3&6 is kept off. If any LEDs is lighted green first and red after or unlighted, it's showing the shielding is bad.

3PK-NT008ENHANCED NETWORK CABLE TESTER

10

Remarks : 1. Please make sure-a 9-volt alkaline battery has been installed in the

battery compartment.2. Remember to always keep the GND switch off, if you are not

testing the shielding.

Caution:Don't connect cable tester to the live circuits as it may be damaged by over voltage.

感謝您選購 網路測試器!

網路測試器已被廣泛的使用於跨網路傳呼系統中。本系

列產品可以自動檢測出網路線上的斷點、短路、開放或交叉重疊

的區域。

在您使用 網路測試器之前,請詳細閱讀本手冊上的操

作指示。

目錄

MT-7051

三合一網路測試器(RJ-45/RJ-11/BNC).....................................13

3PK-NT005

多功能電話端子線測試器(RJ-45/RJ-11)...................................15

3PK-NT007

二合一網路測試器(RJ-45/BNC).....................................17

3PK-NT008

交換式網路線測試器(RJ-45)....................................................19

11

產品介紹

網路測試器能自動且快速地檢測出Ethernet (BNC/TNC), 10-Base-T(UTP/STP), AT&T 258A, TIA568A/B, Token Ring以及

USOC 4/6/8等多種,跨網路線上的斷點、短路、開放或交叉重

疊的區域。只要使用隨機搭配的遠端測試器,不論在網路線安裝

前或安裝後,都可以隨時操作測試,簡單、快速、又有經濟效益

PR1

PR2

Ethernet 10Base-T

PR2

PR3 PR4PR1

EIA/TIA-568A

PR3

PR2 PR4PR1

EIA/TIA-568BAT & T 258A

PR2

PR1

8-positionToken Ring

BNC插頭

BNC 母座

1 2 3 4 5 6 78

PR3

PR2

PR1

USOC 8

1 2 3 4 5 6

PR3

PR2

PR1

USOC 4 (Prs. 1 &2)USOC 6 (Prs 1,2 &3 )

12

1

2

3

4

5

6

7

8

G

B

CABLETESTER

MASTER

OFF ON S

MT-7051

RJ45 + RJ11

1

2

3

4

5

6

7

8

G

REMOTEMT-7051

RJ11 + RJ45

終端電阻

遠端測試器主機

MT-7051

13

MT-7051三合一網路測試器(RJ-45/RJ-11/BNC)

注意:1. 為了您的安全起見,請不要用MT-7051三合一網路測試器測試交流電。

2. 開啟MT-7051時若發現電源指示燈不亮或太暗,請更換9V電池。

如何使用MT-7051三合一網路測試器:1. 打開電源開關至ON的位置,電源指示燈開始閃爍。

("OFF"代表關機;"S"代表低速測試模式)

2. 測試雙絞線時,線路線的一端連接主機(MASTER),另一端連接遠端

測試器(ROMOTE)。

3. 網路連線正常時,訊號燈1~8會陸續亮起,如有訊號燈不亮,表示該

Pin為斷路,網路連線交叉時,主機與遠端測試器燈號也會交叉顯示。

4. 測試同軸電纜線時,將主機連到同軸電纜的一端,並將終端電阻連到

同軸電纜線的另一端。網路連線正常時,訊號燈"B"會亮起綠燈;若燈

號不亮時,網路可能未成功連線,或已發生短路。

備註:

使用前請確認電池匣中已放置一顆全新9V鹼性電池。

警告:MT-7051三合一網路測試器不可用於測試通電回路,不當的使用可能造

成危險的電流過量。

14

MU

LTI-MO

DU

LAR

CA

BLE TESTER

POW

ER

USO

C

ON

OFF

1&8

2&7

3&6

4&5

4P4C6P6C

8P8C

ALL G

REEN- O

K- STRA

IGH

TWIRED

ALL RED

- OK

MIX O

R NO

LIGH

T - M

ISWIRED

- CROSSW

IRED

Modular

CableTerm

inator

RJ12RJ11

RJ45U

SOC

Good LightStraight w

ire

Crosswire

Red Light

Mix or no light 1827

1 4

2 3

3645

162534

Misw

ire

遠端測試器

主機

3PK-N

T005

MU

LTI-MO

DU

LAR

CA

BLE TESTER

POW

ER

USO

C

ON

OFF

1&8

2&7

3&6

4&5

4P4C6P6C

8P8C

ALL G

REEN- O

K- STRA

IGH

TWIRED

ALL RED

- OK

MIX O

R NO

LIGH

T - M

ISWIRED

- CROSSW

IRED

3PK-N

T005

3PK-NT005

15

3PK-NT005多功能電話端子線測試器(RJ-45/RJ-11)

測試USOC 4/USOC 6/USOC 8 模組線路:1. 將網路線一端接到主機,另一端接到遠端測試器(若不需做遠端測試

時,可將網路線兩端皆插到主機上)。

2. 打開電源開關至ON的位置,電源指示燈開始閃爍。

3. 主機開啟的同時,遠端測試器即開始逐一掃瞄訊號。

4. 網路連線正常時,綠色訊號燈會陸續亮起。

5. 網路連線反相時,紅色訊號燈會陸續亮起。

6. 若訊號燈在亮起綠燈後,接著亮起紅燈或是不亮,則表示網路線無法

正常使用。(可能為接觸不良及資訊端子壓著不確實)

備註:

使用前請確認電池匣中已放置一顆全新9V鹼性電池。

警告:3PK-NT005多功能電話端子線測試器不可用於測試通電回路,不當的使

用可能造成危險的電流過量。

16

3PK-NT007

NetworkCable

Terminator

1&2

3&6

4&5

7&8

-GNDGood Pe

Light-Fauity pr108asetToken Ring 258A EIA TIA568

10BASE-TAT&T 258A.

TOKEN RING EIA/TIA568

MULTI-NETWORKCABLE TESTER

Green-good

GND

POWER

ON OFF ON OFF

Red-Bad Ounlit-Open

BNC Indicator<Press To Test BNC

Mix or No

遠端測試器

終端電阻

主機

3PK-NT007

17

3PK-NT007二合一網路測試器(RJ-45/BNC)

測試同軸電纜線(BNC):1. 將同軸電纜線的一端連到主機的BNC插口,另一端連接終端電阻。

2. 打開電源開關至ON的位置,電源指示燈開始閃爍。

3. 按下主機左側的開關,若BNC訊號亮起綠燈,則表示同軸電纜線正常

;若BNC訊號燈不亮,則表示線路無法正常使用或已毀損。

測試10-Base-T, AT& T 258A, EIA/TIA 568, Token Ring Cable:1. 將網路線一端接到主機,另一端接到遠端測試器(若不需做遠端測試

時,可將網路線兩端皆插到主機上)。

2. 打開電源開關至ON的位置,電源指示燈開始閃爍。

3. 主機開啟的同時,遠端測試器即開始逐一掃瞄訊號。網路連線正常時

,綠色訊號燈就會亮起。如果綠色訊號燈亮起後,接著亮起紅燈或是

不亮,則表示網路線無法正常使用。

4. 如果線路被披覆材質遮蔽,請按下GND模式後再開始測試。連線正常

時,除了一組3&6之外,另外三組燈號皆會亮起綠燈,但是若有任何

一個訊號在亮起綠燈後,接著亮起紅燈或是不亮,則表示網路線無法

正常使用。

備註:

1. 使用前請確認電池匣中已放置一顆全新9V鹼性電池。

2. 除非必須測試披覆線路,否則請不要開啟GND開關。

警告:3PK-NT007二合一網路測試器不可用於測試通電回路,不當的使用可能

造成危險的電流過量。

18

Enh

anced

Netw

ork

Cab

le Tester

GREEN

LIGH

T-GO

OD

PAIR

MIX O

R NO

LIGH

T-FAU

LTY PAIR

1&2

ON

OFF

ON

OFF

3&6

4&5

7&8

GN

DPO

WER

10BASE - T

TOKEN

RING

AT&T 258A

EIA/TIA 568

Enh

anced

Netw

ork

Cab

le Tester

GREEN

LIGH

T-GO

OD

PAIR

MIX O

R NO

LIGH

T-FAU

LTY PAIR

1&2

ON

OFF

ON

OFF

3&6

4&5

7&8

GN

DPO

WER

10BASE - T

TOKEN

RING

AT&T 2558A

EIA/TIA 568

Netw

orkCable

Terminator

1&2

3&6

4&5

7&8-G

ND

Good Pr.

Mix or N

oLight-Fauity pt108asetTokenRing258AEIA TIA

568

遠端測試器

主機 3PK

-NT008

3PK-NT008

19

3PK-NT008交換式網路線測試器(RJ-45)

測試10-Base-T, AT&T 258A, EIA/TIA 568以及Token Ring網路線:1. 將網路線一端接到主機上標註▲記號的插口,另一端接到遠端測試器

上(若不需做遠端測試時,可將網路線兩端皆插到主機上)。

2. 打開電源開關至ON的位置,電源指示燈開始閃爍。

3. 主機開啟的同時,遠端測試器即開始逐一掃瞄訊號。

4. 網路連線正常時,綠色訊號燈就會陸續亮起。

5. 網路連線反相時,紅色訊號燈就會陸續亮起。

6. 如果綠色訊號燈亮起後,接著亮起紅燈或是不亮,則表示網路線無法

正常使用。(可能為接觸不良及資訊端子壓著不確實)

7. 如果線路被披覆材質遮蔽,請開啟GND模式後再開始測試。連線正常

時,除了一組3&6之外,另外三組燈號皆會亮起綠燈,但是若有任何

一個訊號在亮起綠燈後,接著亮起紅燈或是不亮,則表示網路線無法

正常使用。

備註:

1. 使用前請確認電池匣中已放置一顆全新9V鹼性電池。

2. 除非必須測試披覆線路,否則請不要開啟GND開關。

警告:3PK-NT008交換式網路線測試器不可用於測試通電回路,不當的使用可

能造成危險的電流過量。

20

NOTE

21

22

寶工實業股份有限公司PROKIT'S INDUSTRIES CO., LTD.

http://www.prokits.com.twE-mail : [email protected]

I n n o v a t i o n • Q u a l i t y • S e r v i c e©2011 Prokit's Industries Co., LTD. All rights reserved. 2011001(T)