Page 1: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

balances

Precision Quality

Satisfaction満足

正確 品質

Page 2: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

Features and Symbols

Reduce manual calibration work

GLP, GMP, AND ISO9000 conformance

Application specifi c features

Other features

Perfect Self CalibrationThe balance self-calibrates when it detects temperature changes that would affect accuracy. Operator is released from constantly monitoring surrounding conditions.

Clock-CALFully automated feature initiates self-calibration at set time intervals, using motor-driven internal calibration weight. Up to three automatic calibrations per day may be pre-set to coincide with work schedules or to meet specifi c quality goals.

Internal CalibrationCalibration can be performed any time with a simple push-button operation.

One-lever CALSingle lever operation loads and unloads built-in calibra-tion weight.

WindowsDirectWeighed result is directly typed at the cursor position of any application on Windows® OS. No communication software is required.

Built-in RS-232C InterfaceRS-232C interface is a standard feature.

Piece Counting ModePiece counting function is a standard feature.

Analog Bar Graph DisplayAllows viewing of remaining capacity.

Specifi c Gravity MeasurementSoftware for specifi c gravity measurement is pre-installed. Simply add optional specifi c gravity kit for effi cient mea-surements.

Standard Below-weigh HookMeasurement beneath the balance is possible.

Interval Timer OutputData can be automatically output at pre-set time intervals.

Auto PrintData can be automatically output as each measurement is made.

Comparator functionCompare samples to target values or pass/fail criteria and clearly indicate the results.

Battery OperationPortable for use in the fi eld.

Formulation modeConvenient for making many measurements of minute samples and seeking the total mass.

Resolution 1/1,020,000High-resolution models with a resolution of 1,020 g/1 mg can accurately detect minute changes in a large mass.

Calibration ReportWith optional printer connected to the balance, calibration reports which meet the requirements of GLP, GMP, and ISO9000 can be produced.

Built-in ClockDate and time can be readily supplied by the balance.

UniBlocSingle-block technology brings high performance and du-rability.

BacklightEasy to read in any environment.

All-metal HousingAll metal construction for high durability.

Easy SettingBest fi t to weighing application.

Menu Operation KeyEasy to operate key layout.

Resolution1

1020000

Page 3: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

Contents

Dual-range semi-micro balances..........................................................................................10

Analytical Balances....................................................................................................................11

Top-Loading Balances..............................................................................................................13

Portable Electronic Balances..................................................................................................16

Precision Platform Balances...................................................................................................17

UniBloc Electronic Moisture Balances................................................................................18

Optional Accessories................................................................................................................20

Service............................................................................................................................................24

Shimadzu balances: Tradition meets innovation..............................................................9

Page 4: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

9

Tradition meets innovation

Shimadzu — a balancemanufacturer since 1918Establish in 1875 in Kyoto, Japan, Shimadzu Corporation is one of the pioneers of scientifi c precision instruments.

Already in 1918 Shimadzu started to produce its own top-pan balances, followed by an equal-beam analytical balance in 1925.

Due to the fact, that weighing was a time-consuming process in the early 20th century, Shi-madzu released a direct reading analytical balance in 1948.

In 1959 Shimadzu also introduced the Roberval mechanism to its toploading balances.

To make instruments more compact and easier, Shimadzu introduced the digital balances in the 70th and in 1977 also the fi rst microprocessor controlled balance.

In 1985 the launch of the next and latest technologies started, thanks to Shimadzu´s patented OPF-technology (one piece forcecell), better known as UniBloc-technology.

Shimadzu balances are today produced under the highest quality standards. Following the Kaizen-procedures, Shimadzu is continously improving its products, too.

UniBloc Technology impoves performances and durabilitiesShimadzu introduced one-piece force cell technology for precision balances in 1989. Today’s UniBloc is created by high-precision electric discharge wire processing applied to a block of aluminum alloy, and replaces the conventional electro-magnetic balance sensor assembly.

UniBloc’s compact, uniform structure ensures stable temperature characteristics, excellent response time and stable corner-load performance.

In addition, the UniBloc design permits a consistency of production that assures reliability and a long operational life.

The updated UniBloc technology expands the UniBloc balance lineup, which now ranges from semi-micro with a minimum display of 0.01 mg to precision platform balances up to 52 kg in capacity.

One-piece force cell patented: in USA in 1989, No. 4799561,in China in 1991, No. 12729, in Japan in 1995, No. 1905686.

Page 5: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

10

Dual-range semi-micro balances AUW-D Series

Electronic Dot-Matrix printers EP80/EP90 optional available.GMP/GLP compliant. Can be used together with Windows-Direct-Function.

Choice of fully-automatic calibrations: PSC and Clock-CALOperator can choose from two types of fully-automatic span calibration methods. «PSC» is initiated based on temperature change detection, and «Clock-CAL» operates at user pre-set times (up to three times a day).

Full automatic calibration: PSC Clock-CAL

Restrainedsensitivity

error band

Ambient temperature change

Fully-automatic calibration

Sen

sitiv

ity e

rror

0

Ambient temperature

Calibrations

SET

SET

SET8:00 12:30 17:30

Reduce manual calibration work GLP, GMP, AND ISO9000 conformancePerfect Self CalibrationThe balance self-calibrates when it detects temperature changes that would affect accuracy. Operator is released from constantly monitoring surrounding conditions.

Clock-CALFully automated feature initiates self-calibration at set time intervals, using motor-driven internal calibration weight. Up to three automatic calibrations per day may be pre-set to coincide with work schedules or to meet specifi c quality goals.

Internal CalibrationCalibration can be performed any time with a simple push-button operation.

One-lever CALSingle lever operation loads and unloads built-in calibration weight.

Application specifi c features

SMK Specifi c Gravity Measurement Kit

Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration

AUW120D 321-80000-31 0,1 / 0,01 mg 120 / 42 g 0,1 / 0,02 mg Yes 0,2 / 0,03mg No AUW120D-V 321-80001-11 0,1 / 0,01 mg 120 / 42 g 0,1 / 0,02 mg Yes 0,2 / 0,03 mg Yes AUW220D 321-80000-32 0,1 / 0,01 mg 220 / 82 g 0,1 / 0,05 mg Yes 0,2 / 0,1 mg No AUW220D-V 321-80001-12 0,1 / 0,01 mg 220 / 82 g 0,1 / 0,05 mg Yes 0,2 / 0,1 mg Yes

Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm

Calibration ReportWith optional printer connected to the balance, calibration reports which meet the requirements of GLP, GMP, and ISO9000 can be produced.

Built-in ClockDate and time can be readily supplied by the balance.

WindowsDirectWeighed result is directly typed at the cursor position of any application on Windows® OS. No communication software is required.

Built-in RS-232C InterfaceRS-232C interface is a standard feature.

Page 6: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

11

Analytical Balances AUW/AUX/AUY Series

Choice of fully-automatic calibrations: PSC and Clock-CAL

Full automatic calibration: PSC

Clock-CAL

Restrainedsensitivity

error band

Ambient temperature change

Fully-automatic calibration

Sen

sitiv

ity e

rror

0

Ambient temperature

Calibrations

SET

SET

SET8:00 12:30 17:30

WindowsDirectWeighed data can be directly typed into any Windows application and no interface software is required. If you’d like to use «WindowsDirect» with «Windows 7», «Windows Vista» or USB port, please contact to our distributors.

Formulation modeConvenient for making many measurements of minute samples and seeking the total mass.

GLP/GMP/ISO calibration report (AUW/AUX models)Meets requirements of GLP/GMP/ISO9000. Calibration reports can be output with date and time, provided by the built-in clock.

Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration

AUW120 321-80000-21 0,1 mg 120 g 0,1 mg Yes 0,2 mg No AUW120V 321-80001-01 0,1 mg 120 g 0,1 mg Yes 0,2 mg Yes AUW220 321-80000-22 0,1 mg 220 g 0,1 mg Yes 0,2 mg No

AUW220V 321-80001-02 0,1 mg 220 g 0,1 mg Yes 0,2 mg Yes AUW320 321-80000-23 0,1 mg 320 g 0,15 mg Yes 0,3 mg No

AUW320V 321-80001-03 0,1 mg 320 g 0,15 mg Yes 0,3 mg Yes AUX120 321-80000-24 0,1 mg 120 g 0,1 mg Yes 0,2 mg No

AUX120V 321-80001-04 0,1 mg 120 g 0,1 mg Yes 0,2 mg Yes AUX220 321-80000-25 0,1 mg 220 g 0,1 mg Yes 0,2 mg No

AUX220V 321-80001-05 0,1 mg 220 g 0,1 mg Yes 0,2 mg Yes AUX320 321-80000-26 0,1 mg 320 g 0,15 mg Yes 0,3 mg No

AUX320V 321-80001-06 0,1 mg 320 g 0,15 mg Yes 0,3 mg Yes AUY120 321-80000-27 0,1 mg 120 g 0,1 mg No 0,2 mg No

AUY120V 321-80001-07 0,1 mg 120 g 0,1 mg No 0,2 mg Yes AUY220 321-80000-28 0,1 mg 220 g 0,1 mg No 0,2 mg No

AUY220V 321-80001-08 0,1 mg 220 g 0,1 mg No 0,2 mg Yes

Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm Ǿ 80 mm

AUW

AUX

AUY

Page 7: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

12

Analytical Balances ATX/ATY Series

ATX

ATY

Piece Counting ModeUnit weights of up to 5 different samples can be easily en-tered, stored and recalled for use.

Comparator functionCompare samples to target values or pass/fail criteria and clearly indicate the results.

Formulation modeConvenient for making many measurements of minute samples and seeking the total mass.

WindowsDirectSend balance data to Excel or other Windows applica-tions without any data communication software installation required. By combining standard AutoPrint functions with typical spreadsheet functions, even diffi cult applications can be easily automated*I/O–RS cable is needed.

Internal CalibrationAutomated calibration can be started by pressing keys. (ATX series)Also, your external calibration weights can be used for span calibration. (All models)

Easy SettingBest fi t to weighing application. Quickly adjust the desired ratio of stability and response for every applica-tion, even during measurement, with one-touch operation.

Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration

ATX84 321-80003-32 0,1 mg 82 g 0,1 mg Yes 0,2 mg No ATX84V 321-80004-02 0,1 mg 82 g 0,1 mg Yes 0,2 mg Yes ATX124 321-80003-33 0,1 mg 120 g 0,1 mg Yes 0,2 mg No

ATX124V 321-80004-03 0,1 mg 120 g 0,1 mg Yes 0,2 mg Yes ATX224 321-80003-34 0,1 mg 220 g 0,1 mg Yes 0,2 mg No

ATX224V 321-80004-04 0,1 mg 220 g 0,1 mg Yes 0,2 mg Yes ATY64 321-80003-36 0,1 mg 62 g 0,1 mg No 0,2 mg No Ǿ 91 mm

ATY64V 321-80004-06 0,1 mg 62 g 0,1 mg No 0,2 mg Yes Ǿ 91 mm ATY124 321-80003-38 0,1 mg 120 g 0,1 mg No 0,2 mg No

ATY124V 321-80004-08 0,1 mg 120 g 0,1 mg No 0,2 mg Yes ATY224 321-80003-39 0,1 mg 220 g 0,1 mg No 0,2 mg No

ATY224V 321-80004-09 0,1 mg 220 g 0,1 mg No 0,2 mg Yes

Ǿ 91 mm Ǿ 91 mm Ǿ 91 mm Ǿ 91 mm

Ǿ 91 mm Ǿ 91 mm Ǿ 91 mm Ǿ 91 mm Ǿ 91 mm Ǿ 91 mm

Page 8: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

13

Analytical Balances UW Series

Formulation modeConvenient for making many measurements of minute samples and seeking the total mass.

Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration

UW220H 321-80006-11 0,001 g 220 g 0,001 g Yes 0,002 g No UW220H-V 321-80007-01 0,001 g 220 g 0,001 g Yes 0,002 g Yes UW420H 321-80006-12 0,001 g 420 g 0,001 g Yes 0,002 g No

UW420H-V 321-80007-02 0,001 g 420 g 0,001 g Yes 0,002 g Yes UW620H 321-80006-13 0,001 g 620 g 0,001 g Yes 0,002 g No

UW620H-V 321-80007-03 0,001 g 620 g 0,001 g Yes 0,002 g Yes UW820H 321-80006-41 0,001 g 820 g 0,001 g Yes 0,003 g No UW1020H 321-80006-42 0,001 g 1020 g 0,001 g Yes 0,003 g No UW2200H 321-80006-16 0,01 g 2200 g 0,01 g Yes 0,02 g No

UW2200H-V 321-80007-06 0,01 g 2200 g 0,01 g Yes 0,02 g Yes UW4200H 321-80006-17 0,01 g 4200 g 0,01 g Yes 0,02 g No

UW4200H-V 321-80007-07 0,01 g 4200 g 0,01 g Yes 0,02 g Yes UW6200H 321-80006-18 0,01 g 6200 g 0,01 g Yes 0,02 g No

UW6200H-V 321-80007-08 0,01 g 6200 g 0,01 g Yes 0,02 g Yes

108×105 108×105 108×105 108×105 108×105 108×105 108×105 108×105 170×180 170×180 170×180 170×180 170×180 170×180

Standard resolutionUW820S 321-80006-15 0,01 g 820 g 0,008 g Yes 0,01 g No

UW820S-V 321-80007-05 0,01 g 820 g 0,008 g Yes 0,01 g Yes UW4200S 321-80006-19 0,1 g 4200 g 0,08 g Yes 0,01 g No UW8200S 321-80006-20 0,1 g 8200 g 0,08 g Yes 0,01 g No

UW8200S-V 321-80007-10 0,1 g 8200 g 0,08 g Yes 0,01 g Yes

170×180 170×180 170×180 170×180 170×180

FastResponce

ExcellentDurability

EasyConnection

Weighing takes jast 0,7–1,2 second (S type).

Long-life design employing a unique weighing mechanism.

WindowsDirect function allows easy data communication to a computer.

Analog display modesBar graph displayBar graph clearly indicates the total weight (including the tare) as a portion of the balance capacity.

Target weighingSelect a target weight and tolerance. The display clearly indicates when they are reached.

CheckweighingSet an upper and lower threshold. The display continually indicates whether the sample is within the range «GO», over range «HI» or under range «LO». Choose one of two checkweighing bar graph display modes.The results can also be output to external devices.

Page 9: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

14

Top-Loading Balances UX Series

Resolution 1/1,020,000High-resolution models with a resolution of 1,020 g/1 mg can accurately detect minute changes in a large mass.

Comparator functionCompare samples to target values or pass/fail criteria and clearly indicate the results.

Specifi c Gravity MeasurementSoftware for specifi c gravity measurement is pre-installed. Simply add optional specifi c gravity kit for effi cient measurements.

Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize, d / g deviation Calibration mm

UX220H 321-80006-01 0,001 g 220 g 0,001 g No 0,002 g No 108×105 UX420H 321-80006-02 0,001 g 420 g 0,001 g No 0,002 g No UX620H 321-80006-03 0,001 g 620 g 0,001 g No 0,002 g No UX820H 321-80006-31 0,001 g 820 g 0,001 g No 0,003 g No UX1020H 321-80006-32 0,001 g 1020 g 0,001 g No 0,003 g No

108×105 108×105 108×105 108×105

UX2200H 321-80006-06 0,01 g 2200 g 0,01 g No 0,02 g No 170×180 UX4200H 321-80006-07 0,01 g 4200 g 0,01 g No 0,02 g No UX6200H 321-80006-08 0,01 g 6200 g 0,01 g No 0,02 g No

170×180 170×180

Standard resolutionUX820S 321-80006-05 0,01 g 820 g 0,008 g No 0,01 g No 108×105 UX8200S 321-80006-10 0,1 g 8200 g 0,08 g No 0,1 g No 170×180

Resolution1

1020000

Calibration range external weights:UW/UX 220H 100–220 gUW/UX 420S/H 100–420 gUW/UX620H 100–620 gUW/UX820S/H 400–820 gUW/UX1020H 500–1020 g UW/UX2200H 1000–2200 gUW/UX4200S/H 1000–4200 gUW/UX6200H 1000–6200 gUW/UX8200S 1000–8200 g

Large-pan model Small-pan model Small-pan model(minimum display 0.01 g) (minimum display 0.001 g)

Resolution1

1020000

Page 10: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

15

Top-Loading Balances TW/TX Series

TW

TX

Internal Calibration (TW series only)Calibration can be performed any time with a simple push-button operation.

Menu Operation KeyMenu Operation Key Easy to operate key layout Menu navigation keys are separated from weighing opera-tion keys and arranged in a familiar 5-way navigation circle. Up, Down, Right, Left and Enter are the simple steps of menu operation.

Easy SettingEasy Setting Best fi t to weighing applicationQuickly adjust the desired ratio of stability and response for every application, even during measurement, with one touch operation.

Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize, d / g deviation Calibration mm

TW223L 321-80010-57 0,001 g 220 g 0,001 g Yes 0,002 g No Ǿ 110 TW223L-V 321-80011-07 0,001 g 220 g 0,001 g Yes 0,002 g Yes Ǿ 110 TW323L 321-80010-58 0,001 g 320 g 0,001 g Yes 0,002 g No Ǿ 110

TW323L-V 321-80011-08 0,001 g 320 g 0,001 g Yes 0,002 g Yes Ǿ 110 TW423L 321-80010-59 0,001 g 420 g 0,001 g Yes 0,002 g No Ǿ 110

TW423L-V 321-80011-09 0,001 g 420 g 0,001 g Yes 0,002 g Yes Ǿ 110 TX223L 321-80010-52 0,001 g 220 g 0,001 g No 0,002 g No Ǿ 110

TX223L-V 321-80011-02 0,001 g 220 g 0,001 g No 0,002 g Yes Ǿ 110 TX323L 321-80010-53 0,001 g 320 g 0,001 g No 0,002 g No Ǿ 110

TX323L-V 321-80011-03 0,001 g 320 g 0,001 g No 0,002 g Yes Ǿ 110 TX423L 321-80010-54 0,001 g 420 g 0,001 g No 0,002 g No Ǿ 110

TX423L-V 321-80011-04 0,001 g 420 g 0,001 g No 0,002 g Yes Ǿ 110 TX2202L 321-80010-62 0,01 g 2200 g 0,01 g No 0,02 g No 167×181

TX2202L-V 321-80011-12 0,01 g 2200 g 0,01 g No 0,02 g Yes 167×181 TX3202L 321-80010-63 0,01 g 3200 g 0,01 g No 0,02 g No 167×181

TX3202L-V 321-80011-13 0,01 g 3200 g 0,01 g No 0,02 g Yes 167×181 TX4202L 321-80010-64 0,01 g 4200 g 0,01 g No 0,02 g No 167×181

TX4202L-V 321-80011-14 0,01 g 4200 g 0,01 g No 0,02 g Yes 167×181 TXC323L-V 321-80011-21 0,001 ct 320 ct 0,0002 g No 0,004 g Yes Ǿ 80 TXC623L-V 321-80011-22 0,001 ct 620 ct 0,0002 g No 0,004 g Yes Ǿ 80 TWC623L-V 321-80011-27 0,001 ct 620 ct 0,0002 g Yes 0,004 g Yes Ǿ 80

Page 11: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

16

Portable Electronic Balances TXB Series

Battery OperationTXB may be operated with dry batteries. Suitable for sites where reliable power supply is not available.

Model PN Min. display Capacity Internal Linearity Verifi able Pansize, d / g Calibration mm

TXB422L 321-80012-53 0,01 g 420 g No 0,02 g No Ǿ 110 TXB622L 321-80012-54 0,01 g 620 g No 0,02 g No Ǿ 110 TXB4201L 321-80012-63 0,1 g 4200 g No 0,2 g No Ǿ 160 TXB6201L 321-80012-64 0,1 g 6200 g No 0,2 g No Ǿ 160

Fast and fl exible calibrationBalance display provides prompts for calibration procedure and accepts your choice of external calibration weight. Convention weight of calibration weights can be input for high accuracy.

Power saving functionWhen weighing operation ends, power automatically turns off after a fi xed or pre-set time.

Many useful functions included• Alpha-numeric menu display• Up-front level indicator on display panel• Door cleaning is simplifi ed• Stainless steel pan• Choice of weighing modes• Zero tracking function and settings• Continuous data function

Expanded Piece Counting functionUnit weights of up to 5 different samples can be easily enterd, stored and recalled for use.

Easy Setting Best fi t to weighing applicationQuickly adjust the desired ratio of stability and response for every application, even during measurement, with one touch operation.

Page 12: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

17

Precision Platform Balances BW-K/BX-K Series

BW-K

BX-K

Large-size calibration weight (BW-K only)For accurate internal calibration. Calibration can be performed by simple lever operation.

GLP/GMP/ISO calibration reportMeets requirements of GLP/GMP/ISO9000. Calibration reports can be output with date and time, provided by the built-in clock.

Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize, d / g deviation Calibration mm

BX-12KH 321-80017-01 0,1 g 12 kg 0,1 g No 0,2 g No BX-22KH 321-80017-02 0,1 g 22 kg 0,1 g No 0,2 g No BX-32KH 321-80017-03 0,1 g 32 kg 0,1 g No 0,2 g No BX32KS 321-80017-04 1 g 32 kg 0,6 g No 1 g No BX52KS 321-80017-05 1 g 52 kg 0,6 g No 1 g No

BW-12KH 321-80017-11 0,1 g 12 kg 0,1 g Yes 0,2 g No BW-22KH 321-80017-12 0,1 g 22 kg 0,1 g Yes 0,2 g No BW-32KH 321-80017-13 0,1 g 32 kg 0,1 g Yes 0,2 g No BW32KS 321-80017-14 1 g 32 kg 0,6 g Yes 1 g No BW52KS 321-80017-15 1 g 52 kg 0,6 g Yes 1 g No

345×250 345×250 345×250 345×250 345×250 345×250 345×250 345×250 345×250 345×250

Analog display modesBar graph displayBar graph clearly indicates the total weight (including the tare) as a portion of the balance capacity.

Target weighingSelect a target weight and tolerance. The display clearly indicates when they are reached.

CheckweighingSet an upper and lower threshold. The display continually indicates whether the sample is within the range «GO», over range «HI» or under range «LO». Choose one of two checkweighing bar graph display modes.The results can also be output to external devices.

Page 13: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

18

UniBloc Electronic Moisture Balances MOC-120H

Large sample pan and capacity allow any sample to be placed for the best drying conditions. Reliable UniBloc weighing mechanism and unique continuous auto-tare system assure accurate measurements.

Large sample pan and continuous auto-tare mechanismA larger sample pan contributes to accurate measurements, but the larger heat capacity of it normally results in a larger zero drift in the precision weighing.The MOC-120H is equipped with a unique continuous auto-taremechanism, which eliminates the zero drift continuously andensures high accuracy, even with a larger sample pan.

Mid-wave infrared quartz heaterMid-wave infrared quartz heater provides effective drying for a wide range of samples. Besides the excellent drying performance, it offers a long operational life of 20,000 to 30,000 hours. Therefore, the long-term operational cost is much lower than halogen lamp heaters.

Different forms of samples can be measured

Various materials can be measured

Moi

stur

eva

poriz

atio

nM

oist

ure

vapo

rizat

ion

Tem

pera

ture

Moi

stur

eva

poriz

atio

n

Ending drying

Pre

dict

ed m

oist

ure

vapo

rizat

ion

Predicted measurement time

Tem

pera

ture

Tem

pera

ture

Tem

pera

ture

5 min

Alternate drying modesRapid drying modeFirst dries with the highest temperaturefor the specifi ed period, then shifts tothe specifi ed temperature shorteningmeasurement time.

Slow drying modeGently heats samples that might solidifyat the surface or samples that reduceunder high temperature.

Step drying modeAllows step-by-step changes in dryingconditions. This feature is useful whenmeasuring samples that contain a largeamount of water.

Predictive measuring modeWith preparatory measurements of the sample, the fi nal result is predicted from the drying process, saving time in repeated measurements.

Figure 2

Moi

stur

e va

poriz

atio

nra

te:

M

Vap

oriz

ed m

oist

ure:

M

t(time)

Bar graph display

Vaporized moisture andvaporization rate

Figure 1

Bar graph display monitors moisture vaporization

What is moisture vaporization rate displayIn drying by infrared heater, a large amount of moisture vaporizes in early stage and vaporization slows towards the end of measurement. The M curve in Figure 2 shows a typical vaporization of moisture. M indicates the rate of vaporization. Monitoring M makes it possible to gauge how close the measurement is to completion. The bar graph display makes it visible. (Figure 1)

Model PN Min. display, Capacity Temperature Standard Internal Linearity Pansize, d / g Range deviation calibration mm

MOC-120H 321-63300-10 0,001 g 120 g 30–200 °C 0,001 g No 0,002 g 130

Page 14: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

19

UniBloc Electronic Moisture Balances MOC63u

Long lifetime halogen heaterHalogen heater promises you quick and accurate measurement.

Large pan sizeLarge sample pan: Ǿ 95 mm

Model PN Min. display, Capacity Temperature Internal Pansize, d / g Range calibration mm

MOC63u 321-80014-12 0,001 g 60 g 50–200 °C No 95

Data management — WindowsDirect and USB connectionThe measurement con-ditions and data can be stored in MOC63u. Data I/O for printer, RS-232C and USB connection for PC are available as stan-dard. Send balance data to Excel or other Win-dows applications.

Easy to remove

Choose the right measuring mode for your application:Measurement modes of MOC63u

200 C

Tem

pera

ture

Moi

stur

eva

poriz

atio

n

Set ending time

Tem

pera

ture

Moi

stur

eva

poriz

atio

n

Ending drying

Tem

pera

ture

Moi

stur

eva

poriz

atio

n

Tem

pera

ture

Moi

stur

eva

poriz

atio

n

Tem

pera

ture

Moi

stur

eva

poriz

atio

n

Automatic ending

Moisture vaporizationover 30 seconds

30 sec

5min

T3

T2

T1

t3t2t1

• Ending modesAutomatic ending modeAutomatically ends measurement when moisture loss over the previous 30 seconds becomes smaller than specifi ed percentage.Timed ending modeAutomatically ends measurement when the specifi ed amount of time has elapsed.

• Alternate drying modesRapid drying modeFirst dries with the highest temperature for the specifi ed period, then shifts to the specifi ed temperature shortening measurement time.Slow drying modeGently heats samples that might solidify at the surface or samples that reduce under high temperature.Step drying modeAllows step-by-step changes in drying condi-tions. This feature is useful when measuring samples that contain a large amount of water.

• Starting modeAutomatic starting modeStarts measurement immediately after closing the lid. It will save time in repeated measure-ment.

Page 15: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

20

Optional Accessories

Common Features for EP-80 and EP-90• Simple connection to balances using

the cable provided.• Uses normal paper, suitable for

long-term storage compatible with GLP/GMP/ISO (dot impact method).

• Operation can be poweredby AC adapter or dry batteries.

• Hassle-free long-use printer paper rolls(8000 lines of printing with one roll).

• High-speed printing at approx.3 lines/sec (printer mechanism performance).

• Installed with statistical calculationfunction as standard.

• Can be used simultaneously withShimadzu’s unique WindowsDirectfunction (output to computer).

Model PN Description

Stablo-EX 321-73000-21 Anti-Static Tool

EP-80 EP-90 EP-100 EP-110

Electronic Printer

EP-80

EP-100

EP-90 print-out sample

Common Features for EP-100 and EP-110• Date and time printing • Automatically set• Statistical calculation • Signature

Features for EP-110• Pipette calibration• Tare/Net/Gross weight printing• SUM mode• Avaraging mode • Comparator mode• Formulation mode • Intermal printing mode• Drycell battery operation • User difi ne caluculation

Model PN Description

EP-80 321-80016-01 Statistic dot matrix printer EP-90 321-80016-11 Enhanced statistic dot matrix printer EP-100 321-80019-01 Statistic dot matrix printer with internal clock and RS-232 interface EP-110 321-80019-02 Enhanced Statistic dot matrix printer

with internal clock and RS-232 interface and displayRibbon cassette 321-61111-06 5 ribbon cassettes for EP80 / EP90

Chart paper 321-62685-02 10 cart papers rolls for EP80 / EP90 AC-adaptor 321-62999-14 AC-adaptor can be used for all balances, printers and STABLO

Windows cable 489-02001 PC-cable for Windows-Direct-function

Static RemoverSecure static removalThe excellent ion polarity balance achieved by the alternating method en-sures:• No inverse charging.• Wide angle static removal.• High performance maintained

over a long period of use.

Space saving designCompact main unit requires minimal space. Holder height and angle are adjustable.

STABLO-EXShimadzu’s unique2-WAY ionizer

Hand-held / On stand

Quickly discharge container or bulk samples with fan ON

For powdered samples, fan can be turned OFF

As a handheld unit

Page 16: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

21

Optional Accessories Overview

AUW-DAUWAUXAUY

ATXATY

AWAXAY

UWUX TX TXB BL ELB BW-K

BX-K MOC-120H MOC63u

EP-80

EP-90

EP-100

EP-110

Printer for MOC-120H

IFB-102A-UNC

I/O RS Cable

Windbreak WBC-102for UW/UX small-pan type

Large size windbreak WBC-502for UW/UX Series

USB conversion kit with RS-232C cable

Foot switch for PRINT FSB-102PK

for TARE FSB-102TK

for TARE FSB-101T

for PRINT FSB-101P

SMK-102, -102

SMK-201for ELB large-pan model

SMK-301

Specifi cgravitymeasurementkit

SMK-401 AUW-Serieswith SMK-401

[no need] [no need] [no need] [no need] [no need]

[no need] [no need] [no need] [no need] [no need] [no need] [no need] [no need]

[no need] [no need]

*1

*1 USB serial adaptor and RS-232C cable for MOC are needed.

Page 17: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

22

Optional Accessories

AUW-D Series AUW/AUX/AUY Series

ATX/ATY Series

UW/UX Series

TW/TX Series

Model PN Description

SMK-401 321-60550-01 Specifi c gravity measurement set for solids Sinker 321-60640 Additional sinker for liquids for SMK-401

Footswitch «Print» 321-60110-11 Footswitch for printing and signal output Footswitch «Tara» 321-60110-12 Footswitch for taring Protective cover 321-62982 5 pcs In-use protective covers for keyboard

Model PN Description

RS-232 321-41167-20 RS-232C Interface, IFB-102A-UNC RS-232 Cable 321-60754-01 RS-232C Cable 25-9P

USB-Kit 321-62520-01 RS-232 Cable attached, RS-232C Interface separately required Protective cover 321-62982 In-use protective Cover (5 pcs)

Model PN Description

SMK-101 321-60576-01 Specifi c gravity measurement set for balances with large pan SMK-102 321-60576-02 Specifi c gravity measurement set for balances with small pan Sinker 321-40580 Sinker Assy for SMK-101 Protective cover XL 321-61228 5 pcs protective cover for balances with large pan (full body) Protectice cover L 321-61229 5 pcs protective cover for balances with small pan (full body) Protective Cover 321-62395-10 5 pcs protective cover for keyboard

Large Windbreak 321-53537 Windbreak for balances with large pan Small windbreak 321-60575-01 Windbreak for balances with small pan

Animal set 321-62150 Bucket set for weighing of small animals 3-door windbreak 321-62795 Tall windbreak with 3 moveable glasdoors (only for small pan) Footswitch «Print» 321-60110-11 Footswitch for printing and signal output Footswitch «Tara» 321-60110-12 Footswitch for taring IFB Interface 321-41167-10 For Multiconnections of UW/UX balances

Model PN Description

Protective Cover 321-64523-10 In-Use protection cover (5 pcs) Protective Cover 321-64522-10 In-Use protective cover for keypad (5 pcs)

Page 18: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

23

Optional Accessories

TXB Series

ELB Series

BW-K/BX-K Series

MOC-120H

Model PN Description

Protective Cover 321-63827-12 In-Use protection cover (5 pcs) Protective Cover 321-63827-11 In-Use protective cover for keypad (5 pcs)

Model PN Description

SMK-201 321-42253 Specifi c gravity measurement set (not for EL/ELB 120/200/300) Protective cover 321-41617-01 In-use protective cover (1 pcs)

Hook 321-34532-03 Below weigh hook IFB-102 321-41167-10 External RS-232 Interface

Model PN Description

Large animal set 321-62545-01 Large bucket for BX-K models (capacity of 22 kg required) Large animal set 321-62545-02 Large bucket for BW-K models (capacity of 22 kg required) Medium animal set 321-62545-03 Medium animal bucket for all BX-K models Medium animal set 321-62545-04 Medium animal bucket for all BW-Kmodels

Hook 321-40962 Below weigh hook Keyboard cover 321-40924 In-use protective cover for keyboard

PC Cable 489-02001 Cable for Windows-Direct function

Model PN Description

Aluminium Sheets 321-63320-02 500 pcs one way sheets (alloy) PC Cable 321-63308 9:9 pins Cable for Windows-Direct function

Printer 321-63305-02 Thermo printer for graphical printout for MOC-120H Chart paper 321-63306-08 10 pcs chart paper for MOC-120H thermo printer Protection Cover 321-64193 In-use Protection cover (5 pcs)

MOC63uModel PN Description

Aluminium Sheets 321-71571-10 Aluminium t=0.1 disposable pans, (50 sheets) Fiberglass Sheets 321-71731 For Measuring liquid sample (100 sheets)

Temp. Cal. Set 321-71520-02 Temperature Calibration Set Protection Cover 321-71512-10 In-use protection cover (5 pcs)

USB Cable set 321-71730-41 2 meter, attached CD Rom for USB Driver

Page 19: Katalog SHIMADZU vaga Specifi c Gravity Measurement Kit Model PN Min. display Capacity Standard Internal Linearity Verifi able Pansize d / mg deviation Calibration AUW120D 321-80000-31

24

Service

PN Description

Verifi cation costs 000-30002-01 Class I balances (AW/AX/AY, AUW-D/AUW/AUX/AUY, ATX/ATY) Verifi cation costs 000-30002-02 Class II Balances (UW, TW/TX) Serie)

IQ/OQ 003-30002-01 Class I balances (AW/AX/AY, AUW-D/AUW/AUX/AUY, ATX/ATY) IQ/OQ 003-30002-02 Class II balances (all other balances in portfolio incl. MOC)

DKD 003-30001-01 DKD-certifi cate provided through german service partner DKD 003-30001-02 DKD-certifi cate provided through german service partner

PLEASE NOTE: Verifi able balances (Ending «V» or «M») must be sell INCLUDING verifi cation!Please add verifi cation cost to end-price.

In case of test weights please ask separately.