Job Name Location Purchaser Engineer Submitted to Reference Approval Construction Unit Designation Schedule # SUBMITTAL Page 1 of 3 www.SamsungHVAC.com * Nominal cooling capacities are based on: Indoor temperature: 80ͼF DB, 67ͼF WB. Outdoor temperature: 95ͼF DB, 75ͼF WB. Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. Refer to www.AHRIdirectory.org for current reference numbers. Specifications AC024MNADCH/AA, AC024MXSCCC/AA Samsung, Low Ambient Cooling, High-Wall Evaporator, Split System AC024MNADCH/AA AC024MXSCCC/AA 24,000 7,000 - 27,000 18.3 / 10.55 10491545 1 / 208-230 / 60 176 - 254 (max. 3% deviation from each) 1.8 / 10.0 / 15.0 20 16.0 41 15/16 X 11 7/8 X 11 9/16 34 5/8 X 31 7/16 X 12 3/16 32.19 114.64 Aluminum Fin / Copper Tube 32 / 35 / 39 / 43 50 23 ≤ T ≤ 115 -40 ≤ T ≤ 115 w/wind baffle 61 ≤ T ≤ 90 1/4" 5/8" 164 98 11/16" OD R410A Electronic Expansion Valve 70.56 25 ft 0.11 oz/ft over 25 ft Samsung Inverter Driven, BLDC, Rotary 10.5 BLDC with Crossflow fan (1) 410 / 477 / 551 27 W / 0.70 A BLDC With Axial Type Fan (1) 0.9 A / 89 W / 1,801 CFM MWR-SH00N MWR-WE11N MRW-TA MIM-B14 MIM-N01 CKN-250 WBF-2M 25' - ILS2509 50' - ILS5009 Wall-mounted evaporator Low ambient cooling to -40° The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire Auto-restart after power loss The outdoor unit shall have a snow accumulation prevention option setting to prevent snow drifting against an idle outdoor unit. The indoor unit shall have a removable EEPROM that stores system programming information, unit name, and other data All indoor unit addressing and option settings shall be done digitally; the indoor unit does not contain rotary dials or setting switches. The outdoor unit shall have a night time quiet mode option to reduce operating sound during the night. Construction The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability Indoor unit chassis shalle be UL94 V0 with a galvanized steel mounting plate Heat Exchanger The indoor unit and outdoor unit heat exchangers shall be mechanically bonded aluminum fin to copper tube Interconnect control wire between outdoor indoor unit shall be 16AWG X 2 shielded Wired or wireless controls must be purchased separately Connection to optional wired controllers shall be 2 X 16AWG shielded wire Controls shall integrate with a BMS system The system shall integrate with the Samsung NASA Controls Solution No additional interface modules/adapters are required when connecting to Samsung NASA DVM S central control options (MIM-D01AUN, MIM-B17BUN, MIM-B18BUN, MCM-A300N). Refrigerant System The refrigerant shall be R410A The compressor shall be hermetically sealed, inverter controlled, BLDC Rotary Refrigerant flow shall be controlled by an electronic expansion valve at outdoor unit Soft-start to reduce current demand during compressor start Warranty 7 Years compressor, 5 years parts with registration MIM-H03UN WBB-7M Nominal Capacity Btu/h Btu/h Voltage ø / V / Hz Max. Breaker Amps Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit dB(A) (Silent) / L / M / H Outdoor Unit dB(A) High High side (flare) Low side (flare) Factory Charge oz. RLA Amps Air Volume CFM (L/M/H) Simplified Premium w/scheduling Simplified Touch Controller Front Back Certifications Safety ETL (UL 1995) Optional Accessories External Contact Control Central Control Interface Module for Connection to DVM Plus Controls (non-NASA) Wall Bracket (for outdoor unit) Wind Baffles Line Sets - insulated and flared, interconnect cables included Devices: PCB fuses, indoor unit terminal block thermal fuse, current transformer, over-voltage protection, crankcase heating, temperature limit protection logic, compressor overload sensing External Temperature Sensor Wi-Fi Adapter Wired Controller FLA / W / CFM (max.) Refrigerant Type Control Method Charged for Additional Refrigerant Compressor Manufacturer Type Evaporator Fan Type Condenser Fan Motor Output (W) / FLA (A) Operating Temperatures Outdoor Indoor Pipe Connections Indoor & Outdoor Maximum (ft.) Maximum Vertical Separation (ft.) Condensate Connection W X H X D (in.) Weight (lbs.) Heat Exchanger Indoor & Outdoor Unit Type Sound Pressure Level Dimensions Model Indoor Unit Model Number Outdoor Unit Model Number AHRI Certification Number Power Working Voltage Range (VAC) Operating Current min. / std. / max. Min. Circuit Ampacity (A) Performance Capacity Range SEER / EER MWR-SH10N Wireless Controller MR-EH00U 7KH LQGRRU XQLW VKDOO KDYH HDV\DFFHVV to ZLUH SLSH DQG GUDLQ FRQQHFWLRQV YLD access SDQHO RQ IURQW RI XQLW IRU HDVLHU LQVWDOODWLRQ DQG VHUYLFH °F °F Controls Notice: US Federal law requires that the above model to be installed in all U.S. states and territories except in AZ, CA, NM, and NV. Federal law prohibits installation of this unit in these states. Advanced configuration options for high room temperature alerts using MIM-B14 external contact control to enable a backup system and/or to notify a BMS (refer to technical documents available at www.DVMdownload.com for full details). Control signal shall be a DDC type signal © 2018 Samsung HVAC SHA-CAC-06192018 888-699-6067 www.SamsungHVAC.com

Upload: leliem

Post on 19-Aug-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

Job Name LocationPurchaser EngineerSubmitted to Reference Approval ConstructionUnit Designation Schedule #

SUBMITTAL Page 1 of 3 www.SamsungHVAC.com

* Nominal cooling capacities are based on: Indoor temperature: 80 F DB, 67 F WB. Outdoor temperature: 95 F DB, 75 F WB.

Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. Refer to www.AHRIdirectory.org for current reference numbers.

Specifications

AC024MNADCH/AA, AC024MXSCCC/AA Samsung, Low Ambient Cooling, High-Wall Evaporator, Split System

AC024MNADCH/AAAC024MXSCCC/AA

24,0007,000 - 27,00018.3 / 10.5510491545

1 / 208-230 / 60176 - 254 (max. 3% deviation from each)

1.8 / 10.0 / 15.020

16.041 15/16 X 11 7/8 X 11 9/1634 5/8 X 31 7/16 X 12 3/16

32.19114.64

Aluminum Fin / Copper Tube

32 / 35 / 39 / 4350

23 ≤ T ≤ 115-40 ≤ T ≤ 115 w/wind baffle

61 ≤ T ≤ 90

1/4"5/8"16498

11/16" OD

R410AElectronic Expansion Valve

70.5625 ft

0.11 oz/ft over 25 ft

SamsungInverter Driven, BLDC, Rotary

10.5

BLDC with Crossflow fan (1)410 / 477 / 55127 W / 0.70 A

BLDC With Axial Type Fan (1)0.9 A / 89 W / 1,801 CFM

MWR-SH00N

MWR-WE11N

MRW-TAMIM-B14

MIM-N01

CKN-250WBF-2M

25' - ILS250950' - ILS5009

• Wall-mounted evaporator

• Low ambient cooling to -40°

• The outdoor unit shall supply power to indoor unit via 14 AWG X 3 power wire

• Auto-restart after power loss

• The outdoor unit shall have a snow accumulation prevention option setting to prevent snow drifting against an idle outdoor unit.

• The indoor unit shall have a removable EEPROM that stores system programming information, unit name, and other data

• All indoor unit addressing and option settings shall be done digitally; the indoor unit does not contain rotary dials or setting switches.

• The outdoor unit shall have a night time quiet mode option to reduce operating sound during the night.

Construction The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability

Indoor unit chassis shalle be UL94 V0 with a galvanized steel mounting plate

Heat Exchanger The indoor unit and outdoor unit heat exchangers shall be mechanically bonded aluminum fin to copper tube

Interconnect control wire between outdoor indoor unit shall be 16AWG X 2 shielded

Wired or wireless controls must be purchased separately

Connection to optional wired controllers shall be 2 X 16AWG shielded wire

Controls shall integrate with a BMS system

The system shall integrate with the Samsung NASA Controls Solution

No additional interface modules/adapters are required when connecting to Samsung NASA DVM S central control options (MIM-D01AUN, MIM-B17BUN, MIM-B18BUN, MCM-A300N).

Refrigerant System The refrigerant shall be R410A

The compressor shall be hermetically sealed, inverter controlled, BLDC Rotary

Refrigerant flow shall be controlled by an electronic expansion valve at outdoor unit

Soft-start to reduce current demand during compressor start

Warranty 7 Years compressor, 5 years parts with registration

MIM-H03UN

WBB-7M

Nominal Capacity Btu/hBtu/h

Voltage ø / V / Hz

Max. Breaker Amps

Indoor UnitOutdoor UnitIndoor UnitOutdoor Unit

Indoor Unit dB(A) (Silent) / L / M / HOutdoor Unit dB(A) High

High side (flare)Low side (flare)

Factory Charge oz.

RLA Amps

Air Volume CFM (L/M/H)

Simplified

Premium w/schedulingSimplified Touch Controller

FrontBack

CertificationsSafety

ETL (UL 1995)

Optional Accessories

External Contact ControlCentral Control Interface Module for Connection to DVM Plus Controls (non-NASA)Wall Bracket (for outdoor unit)

Wind Baffles

Line Sets - insulated and flared, interconnect cables included

Devices: PCB fuses, indoor unit terminal block thermal fuse, current transformer, over-voltage protection, crankcase heating, temperature limit protection logic, compressor overload sensing

External Temperature SensorWi-Fi Adapter

Wired Controller

FLA / W / CFM (max.)

Refrigerant

TypeControl Method

Charged for Additional Refrigerant

CompressorManufacturer Type

Evaporator FanType

Condenser FanMotor

Output (W) / FLA (A)

Operating Temperatures

Outdoor

Indoor

Pipe Connections

Indoor & Outdoor

Maximum (ft.)Maximum Vertical Separation (ft.)Condensate Connection

W X H X D (in.)Weight (lbs.)

Heat Exchanger Indoor & Outdoor Unit Type

Sound Pressure Level

Dimensions

ModelIndoor Unit Model NumberOutdoor Unit Model Number

AHRI Certification Number

PowerWorking Voltage Range (VAC)Operating Current min. / std. / max.

Min. Circuit Ampacity (A)

Performance Capacity RangeSEER / EER

MWR-SH10N

Wireless Controller MR-EH00U

to access

°F

°F

Controls

Notice: US Federal law requires that the above model to be installed in all U.S. states and territories except in AZ, CA, NM, and NV. Federal law prohibits installation of this unit in these states.

Advanced configuration options for high room temperature alerts using MIM-B14 external contact control to enable a backup system and/or to notify a BMS (refer to technical documents available at www.DVMdownload.com for full details).

Control signal shall be a DDC type signal

© 2018 Samsung HVAC SHA-CAC-06192018

888-699-6067 www.SamsungHVAC.com

888-699-6067 www.SamsungHVAC.com

Page 2 of 3 SUBMITTAL AC024MNADCH/AA, AC024MXSCCC/AASamsung, Low Ambient Cooling, High-Wall Evaporator, Split System AC024MNADCH/AA Dimensional Drawing

1 Liquid pipe connection2 Gas pipe connection3 Drain pipe connection4 Power supply & Communication wiring conduit

1/4"5/8"

11/16" OD

No. Name Description

41 15/16"

41 15/16"

11 9/16"

11 7

/8"

2 5/16"

3 1/

4"3

13/1

6"

11 1/4" 11 1/4"

11 7

/8"

2 9/16"

6 5/8"

1 5/

16"

15/1

6"

4 5/16" 3 5/16"22 7/16"

Ø 2 9/16"6 5/8"

3 5/16" 4 5/16"

1 5/

16"

2 1/

2"

3/16"5

2 7/16"

888-699-6067 www.SamsungHVAC.com

Page 3 of 3 SUBMITTAL AC024MNADCH/AA, AC024MXSCCC/AASamsung, Low Ambient Cooling, High-Wall Evaporator, Split System AC024MXSCCC/AA Dimensional Drawing

No. Name Description

123

Gas Pipe ConnectionLiquid pipe ConnectionDrain Hole

Ø 1/4" FlareØ 5/8 Flare

36 9/16"

14 1

/2"

14 5

/16"

12 3/16"34 5/8"

9/16"

1 1/

8"26"

9 1/8"

9 7/16"

5 11

/16"

8 7/

16"

31 7

/16"

1"13

1/4

"

2 1/

16"

4 5/16"

21 1/4"25 11/16"

1 1/4"1 1/2"6 9/16"

7 1/

4"

2 13

/16"

1 5/

8"

1 5/

16"