Submittal Data Sheet Project Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit #: Drawing #: Performance FTXG12HVJU Indoor Unit Model No: RXG12HVJU Outdoor Unit Model No: 12000 Rated Cooling Capacity (Btu/hr): 10130 Sensible Capacity (Btu/hr): 15700/5300 Max/Min Cooling Capacity (Btu/hr / kW): 0.889 Cooling Input Power (kW): 24.2 SEER: 16000 Rated Heating Capacity (Btu/hr): 19100/4400 Max/Min Heating Capacity (Btu/hr / kW): 1.191 Heating Input Power (kW): 4.04 Heating COP (Btu/hr / Btu/hr): 10.55 HSPF: Quaternity Wall Mounted Indoor Unit Type: Quaternity Heat Pump Condensing Unit Type: Indoor: 80°F DB/67°F WB Rated Cooling Outdoor: 95°F DB/75°F WB Conditions Indoor: 70°F DB/60°F WB Rated Heating Outdoor: 47°F DB/43°F WB Conditions 25 Rated Piping Length(ft) 0 Rated Height Separation(ft) Indoor Unit Details 208-230/60/1ph Power Supply (V/Hz/Ph:) L1, L2, Ground Power Supply Connections: N/A Min Circuit Amps MCA (A): N/A Max Overcurrent Amps MFA (A): 12x35-1/32x8-7/32 Dimensions (HxWxD): N/A Panel (HxWxD): 31 Net Weight (lbs): Weight with Panel (lbs): 459/346/240 Airflow Rate (CFM wet coil) 4.86 Moisture Removal (pt/h): 3/8 Gas Pipe Connection (inch): 1/4 Liquid Pipe Connection (inch): 11/16 Condensate Connection (inch): 43 Sound Pressure Level (dBA): Sound Power Level (dBA): 0 / 0/0 Static Pressure Rated/Max (inWg) Condensing Unit Details 208-230/60/1ph Power Supply (V/Hz/Ph): L1, L2, Ground Power Supply Connections: 14.5 Min. Circuit Amps MCA (A): 15 Max. Overcurrent Amps MFA (A): Max. Starting Current MSC(A): 3.3 Rated Load Amps RLA (A): 22-3/8x31-9/32x11-7/32 Dimensions (HxWxD): 99 Net Weight (lbs): Inverter Compressor Type: Capacity Control Range (%): 1262 Airflow Rate (CFM): 3/8 Gas Pipe Connection (inch): 1/4 Liquid Pipe Connection (inch): 49 Sound Pressure Level (dBA): Sound Power Level (dBA): System Details R-410A Refrigerant Type: 3.1 Holding Refrigerant Charge (lbs): Additional Charge (oz/ft): 33 ft Pre-charge Piping (Length ft): 33 ft Max. Pipe Length (Total ft): 26 ft Max. Pipe Length (Vertical ft): 14 - 109 Cooling Operation Range (°F): 14 - 109 Cooling Range w/Baffle (°F): (-4) - 75 Heating Operation Range (°F): -4 - 75 Heating Range w/Baffle (°F): Page 1 of 4 Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006 Daikin AC TRL Generated Submittal Data www.daikinac.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)

Upload: ngoanh

Post on 31-Mar-2018

227 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: Submittal Data Sheet -  · PDF fileSubmittal Data Sheet Project Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit #: Drawing #:

Submittal Data Sheet

Project Name:

Location: Engineer:

Submitted to: Submitted by: Reference:

Approval: Date: Construction:

Unit #: Drawing #:

Performance

FTXG12HVJUIndoor Unit Model No:

RXG12HVJUOutdoor Unit Model No:

12000Rated Cooling Capacity (Btu/hr):

10130Sensible Capacity (Btu/hr):

15700/5300Max/Min Cooling Capacity (Btu/hr / kW):

0.889Cooling Input Power (kW):

24.2SEER:

16000Rated Heating Capacity (Btu/hr):

19100/4400Max/Min Heating Capacity (Btu/hr / kW):

1.191Heating Input Power (kW):

4.04Heating COP (Btu/hr / Btu/hr):

10.55HSPF:

Quaternity Wall MountedIndoor Unit Type:

Quaternity Heat PumpCondensing Unit Type: Indoor: 80°F DB/67°F WB

Rated Cooling Outdoor: 95°F DB/75°F WB

Conditions

Indoor: 70°F DB/60°F WBRated Heating

Outdoor: 47°F DB/43°F WBConditions

25Rated Piping Length(ft)

0Rated Height Separation(ft)

Indoor Unit Details

208-230/60/1phPower Supply (V/Hz/Ph:)

L1, L2, GroundPower Supply Connections:

N/AMin Circuit Amps MCA (A):

N/AMax Overcurrent Amps MFA (A):

12x35-1/32x8-7/32Dimensions (HxWxD):

N/APanel (HxWxD):

31Net Weight (lbs):

Weight with Panel (lbs):

459/346/240Airflow Rate (CFM wet coil)

4.86Moisture Removal (pt/h):

3/8Gas Pipe Connection (inch):

1/4Liquid Pipe Connection (inch):

11/16Condensate Connection (inch):

43Sound Pressure Level (dBA):

Sound Power Level (dBA):

0 / 0/0Static Pressure Rated/Max (inWg)

Condensing Unit Details

208-230/60/1phPower Supply (V/Hz/Ph):

L1, L2, GroundPower Supply Connections:

14.5Min. Circuit Amps MCA (A):

15Max. Overcurrent Amps MFA (A):

Max. Starting Current MSC(A):

3.3Rated Load Amps RLA (A):

22-3/8x31-9/32x11-7/32Dimensions (HxWxD):

99Net Weight (lbs):

InverterCompressor Type:

Capacity Control Range (%):

1262Airflow Rate (CFM):

3/8Gas Pipe Connection (inch):

1/4Liquid Pipe Connection (inch):

49Sound Pressure Level (dBA):

Sound Power Level (dBA):

System Details

R-410ARefrigerant Type:

3.1Holding Refrigerant Charge (lbs):

Additional Charge (oz/ft):

33 ftPre-charge Piping (Length ft):

33 ftMax. Pipe Length (Total ft):

26 ftMax. Pipe Length (Vertical ft):

14 - 109Cooling Operation Range (°F):

14 - 109Cooling Range w/Baffle (°F):

(-4) - 75Heating Operation Range (°F):

-4 - 75Heating Range w/Baffle (°F):

Page 1 of 4Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006

Daikin AC TRL Generated Submittal Data www.daikinac.com

(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)

Page 2: Submittal Data Sheet -  · PDF fileSubmittal Data Sheet Project Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit #: Drawing #:

Submittal Data Sheet

Project Name:

Location: Engineer:

Submitted to: Submitted by: Reference:

Approval: Date: Construction:

Unit #: Drawing #:

Dimensional Drawing - Indoor Unit FTXG12HVJU

Page 2 of 4Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006

Daikin AC TRL Generated Submittal Data www.daikinac.com

(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)

Page 3: Submittal Data Sheet -  · PDF fileSubmittal Data Sheet Project Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit #: Drawing #:

Submittal Data Sheet

Project Name:

Location: Engineer:

Submitted to: Submitted by: Reference:

Approval: Date: Construction:

Unit #: Drawing #:

Dimensional Drawing - Condensing Unit RXG12HVJU

Page 3 of 4Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006

Daikin AC TRL Generated Submittal Data www.daikinac.com

(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)

Page 4: Submittal Data Sheet -  · PDF fileSubmittal Data Sheet Project Name: Location: Engineer: Submitted to: Submitted by: Reference: Approval: Date: Construction: Unit #: Drawing #:

Submittal Data Sheet

Project Name:

Location: Engineer:

Submitted to: Submitted by: Reference:

Approval: Date: Construction:

Unit #: Drawing #:

FTXG12HVJU RXG12HVJU

FTXG12HVJU

Std U.S. Warranty: 7yrs Compressor, 5yrs Parts

RXG12HVJU

Std U.S. Warranty: 7yrs Compressor, 5yrs Parts

Page 4 of 4Daikin AC (Americas), Inc., 1645 Wallace Drive - Suite 110, Carrollton, TX 75006

Daikin AC TRL Generated Submittal Data www.daikinac.com

(Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations)