italo urban brochure 29-01-2014 small
DESCRIPTION
ItaloTRANSCRIPT
Italo urban
External Lighting CatalogueOverview
Italoexclusive design
urban
Design
LED LIGHTINGmodel Italo Urban3
Aesthetic design certainly played a signifi-cant role in the design process. The new LED product range is characterized by a defined light-style, as a result of accurate research on forms and light perception. AEC opens up new frontiers in outdoor lighting, promoting design excellence and optimum performance.
2
Great design is all about details. With innovative material selection,
sensible construction techniques and modern aesthetics one can craft a unique design language that sets a new standard.
Design
LED LIGHTINGmodel Italo Urban5
Aesthetic design certainly played a signifi-cant role in the design process. The new LED product range is characterized by a defined light-style, as a result of accurate research on forms and light perception. AEC opens up new frontiers in outdoor lighting, promoting design excellence and optimum performance.
4
PROTECTION AGAINST OVERVOLTAGE
A lighting device installed in a standard elec-trical system may be subjected to voltagefluctuations and external disturbances due to different factors such as discontinuous loads on the line, faults on the lines (upstream or downstream) and atmospheric electricaldischarges (in outdoor installations). In those LED installations where the electronic com-ponents are predominant, an adequate resis-tance to surges is synonymous with reliability and proper functionality.Thanks to the research and the experimenta-tion performed in its own laboratories, AECoffers its customers customized solutions ac-cording to every specific installation.
CLASS I: protection up to 10kV.CLASS II: protection from 5kV up to 9kV.
For more information about the protection against overvoltage, please download the technical report at
Possibility to install a twilight switch that allows to automatically turn the unit on at sunset and to turn it off at sunrise.
FC (PHOTOCELl) OPTION
Light flux regulation using power line communication.Light flux reduction can be associated with punctual and remote monitoring of the individual device via the power line com-munication remote control. This option, used in conjunction with an LCU (Light Control Unit), makes it possible to control an individual lighting point, allowing the creation of customised lighting scenarios. More complex remote control panels can be used as part of a wireless or GSM/GPRS network, to remotely monitor the energy consumption of the system and provide fault indications as necessary without the need for on-site maintenanceprocedures.
PLM OPTION
LED LIGHTINGmodel Italo Urban11
Detail
10
LED LIGHTINGmodel Italo Urban13
materials
12
POLESteel pole in any variety you can imagine...
BRACKET
Post top or brackets mountingin die cast aluminum
HEAT SINK
Heat sink in die cast aluminum UNI EN 1706 with lamellar de-sign.01).
FRAMEFrame and cover in die cast alumi-num alloy UNI EN 1706.
CLOSURE
Closure hook in extruded aluminum with stainless steel spring.
Housing: Extrude aluminium
Ballast Compartment: Extruded aluminium
Heat sink Extruded aluminium
Optic High efficiency metalized polycarbonate
Screen Tempered 4mm th.
Cable clamp PlasticM20x1.5 - IP68
Standard colour Graphite (GGT)
Ordering sequence(Model Name) + (Wattage plus Current) + (Desired Voltage) +
(Optical System) + (Options) + (Color)
110÷277V 50/60Hz
Voltage:
Color:BLT - black texure
WHT - white texture
GGT - graphite grey
BLUT - blue texture
GRNT - green texture
SLT - silver texture* - please remove letter T if flat finish is requested (not recommended)
Control system:- DIM-FIX: Fixed and programmed current
- DIM-AUTO: Automatic dimming profile with integrated timer
- DIM-PROG: Automatic and programmable dimming profile
- PLM: Conveyed wave (Power Line Management)
Optical unit:Solid state optical system made with 18-27-36-45-54 LED
Colour Temperature 6000K, 4000K, 3000K
IES Type II, III, IV, V
Optical unit life:(Ta=25°C)
525 mA≥70.000hr B20L80 (including critical failures)
≥90.000hr L80, TM21
700 mA≥50.000hr B20L80 (including critical failures)
≥70.000hr L80, TM21
Options:PCR - Photocell Receptacle (pole mounted)
HSS - House Side Shield
FG - Frosted glass
LAMP CODE DEFINITION
40 W | 36 LED | 4 K
Lamp wattage
Number of diodes
CoLor temperature
LED LIGHTINGmodel Italo Urban15
technical sheet
ELECTRICAL CHARACTERISTICS
• Insulation class: I, II.
• Power supply: 230V - 50Hz.
• Ferromagnetic power supplyunit, efficiency EEI = A3.
• Superimposed pulse ignitorwith timer upon request.
• Power factor: > 0.9 (at fullload).
• Connection for cables featuredby a maximum cross section of4mmq.
• Integrated on-load switch forluminaires in class II.
• Anti-burst capacitor.
• Ceramic lamp holder.luminaires in class II.
• Anti-burst capacitor.
• Ceramic lamp holder.
14
technical sheet
LED LIGHTINGmodel Italo Urban1716Gamma Angles
cd/klm
180 120
105
90
75
60
45
105
90
75
60
45
30 3015 150
100
100
200
300
400
500
Gamma Angles 180 120
105
90
75
60
45
105
90
75
60
45
30 3015 150
150
150
300
450
600
750 cd/klm
Gamma Angles 180 120
105
90
75
60
45
105
90
75
60
45
30 3015 150
150
150
300
450
600
750 cd/klm
Gamma Angles 180 120
105
90
75
60
45
105
90
75
60
45
30 3015 150
150
150
300
450
600
750 cd/klm
Gamma Angles 180 120
105
90
75
60
45
105
90
75
60
45
30 3015 150
90
90
180
270
360
450 cd/klm
Gamma Angles 180 120
105
90
75
60
45
105
90
75
60
45
30 3015 150
150
150
300
450
600
750 cd/klm
DIMMING OPTIONS
LED technology offers easy and reliable light flux adjustment. The devices are equipped with an electronic power sup-ply capableof adjusting light emission by directly regulating the optical assembly LED in-put current. The standard version of the device issupplied with a constant LED input cur-rent of 525mA or 700mA.The following options are available:
DA (DIM-AUTO) OPTIONAutomatic light flux regulation
DAC OPTION (DIM-AUTO custom pro-file)The power supply is configured using a dimming profile totally customizable by the user (up to 5 levels in 4 steps).
PLM OPTIONLight flux regulation using power line communication
LCU OPTIONLight control unit
OPTIONS ON REQUEST:
D10 (DIM-10) OPTIONFlux adjustment via 1-10V analogue con-trol
DALI OPTION (Digital Addressable Light-ing Interface)Flux adjustment via digital interface
DB (DIM-BIP) OPTIONBi-power light flux adjustment with pilot cable
DR (DIM-REG) OPTIONLight flux adjustment with flux controllers
ADDITIONAL OPTIONS
FLC OPTIONLED light flux recovery
FR (FULL RANGE) OPTION - Extended in-put voltage range
FC (PHOTOCELl) OPTIONPossibility to install a twilight switch that allows to automatically turn the unit on at sunset and to turn it off at sunrise.
SSymmetric optic
Gamma Angles 180 120
105
90
75
60
45
105
90
75
60
45
30 3015 150
80
80
160
240
320
400 cd/klm
Rotosymmetrical optic for ur-ban and parking areas lighting.
TSStreet optics for road center
Asymmetrical optic for street lighting (suspended mounting).
STWWide emission street optic
Asymmetrical optic for wide streets and wet asphalt. Specif-ic optic for roadways where the width corresponds to 1,2 times the pole height.
STU-SUrban street optic
Asymmetrical optic for street and cycle path lighting. Specific optic for roadways where the width corresponds to 0,8 times the pole height.
STU-MUrban street optic
Asymmetrical optic for street and cycle path lighting. Specific optic for roadways where the width is equivalent to the pole height.
STE-SSuburban street optic
Asymmetrical optic for street and motorway lighting. Specif-ic optic for roadways where the width corresponds to 0,8 times the pole height.
STE-MSuburban street optic
Asymmetrical optic for street and motorway lighting. Specif-ic optic for roadways where the width is equivalent to the pole height.
mountings
Luminaire Flux¹(Ta=25°, 4000K, lm)
modules525mA 700mA
STE-M/STE-S/STW Optic
1 2060 2600
2 4120 5170
3 6180 7760
4 8240 10350
5 10300 12940
6 12360 15520
7 14410 -
8 16470 -
modules STU-M / STU-S Optic
1 1550 1940
2 3090 3880
3 4640 5830
4 6180 7760
5 7730 9710
6 9270 11640
7 10820 13590
8 12360 15520
9 13900 -
Rated LED Flux²(Ta=85°, 4000K, lm)
525mA 700mA
STE-M/STE-S/STW Optic
2445 3057
4890 6114
7335 9171
9780 12228
12225 15285
14670 18342
17115 -
19560 -
STU-M/STU-S Optic
1814 2239
3628 4478
5442 6717
7256 8956
9070 11195
10884 13434
12698 15673
14512 17912
16326 -
Rated Luminaire Power¹(Ta=25°, VIN=230 Vac, W)³
modules525mA 700mA
STE-M/STE-S/STW Optic
1 20 26
2 39 53
3 59 79
4 79 105
5 98 131
6 118 158
7 138 -
8 158 -
modules STU-M/STU-S Optic
1 15 20
2 30 40
3 44 59
4 59 79
5 74 99
6 89 119
7 103 138
8 118 158
9 133 -
Rated LED Power²(Ta=85°, W)
525mA 700mA
STE-M/STE-S/STW Optic
17 24
35 47
52 71
70 94
87 118
105 141
122 -
139 -
STU-M/STU-S Optic
13 17
26 34
39 51
52 69
65 86
78 103
91 120
104 137
116 -
The tables below describe the flux and output power of the available versions. These parameters are necessary in order to guarantee a correct comparison of the luminaire performance. In particular, the luminaire efficiency (expressed in lm/W) must be calculated as the ratio between the output luminous flux of the luminaire and the power absorbed by the input power supply unit. For the sake of completeness the tables also show the data of the nominal flux and power of the used LED.
ELECTRICAL CHARACTERISTICS
• Power supply:110÷277V - 50/60Hz.
• LED current: 525/700mA.
• Power Factor: >0.9 (at full load).
• Connection for cables featured by a maximum cross section of 4mmq.
• Optional fuse
• Optical unit lifetime525mA:>70.000hr B20L80(included critical failures);>90.000hr L80, TM-21;700mA:>50.000hr B20L80(included critical failures);>70.000hr L80, TM-21.
• Available dimming options:DA: automatic dimming.DAC: customizable DAprofile.PLM: power linecommunication light fluxadjustment.
Installation rep.L/H
ITALO 2 URBAN ITALO 2 URBAN ITALO 2 URBAN
H
L1.5 STW
H
L1.25 STW
STU-M STW
H
L1 STE-M STU-M
H
L0.75 STE-S STU-S
STU-S STE-M
H
L0.5
UNI EN 13201Lighting categories
CEO
ME1
CE1
ME2
CE2
ME3
CE3
ME4
CE4
ME5
CE5
ME6
CE6
S1 S2 S3 S4 S5 S6
MEW 1
MEW 2
MEW 3
MEW 4
MEW 5
Street Application Cycle path ApplicationStreet Application
WET Class
SELECTION OF THE OPTICS ACCORDING TO UNI EN 13201 LIGHTING CATEGORIES
582 mm | 22 7/8”
470 mm
| 18 1/2”
Ø 60 | 2 3/8”
582 mm | 22 7/8”
526 mm
| 22 3/4”
685 mm | 27”
121 mm
| 4 3/4”
542 | 21 3/8” mm
526 mm
| 22 3/4”
542 mm | 21 3/8” mm
264 mm
| 10 3/8” mm
542 mm | 21 3/8” mm
526 mm
| 22 3/4”
Ø 6-12 mm
542 mm | 21 3/8” mm
302 mm
| 22 7/8”
Ø 60 mm | 2 3/8”76 mm | 3” optionalØ
582 mm | 22 7/8”
470 mm
| 18 1/2”
Ø 60 | 2 3/8”
582 mm | 22 7/8”
526 mm
| 22 3/4”
685 mm | 27”
121 mm
| 4 3/4”
542 | 21 3/8” mm
526 mm
| 22 3/4”
542 mm | 21 3/8” mm
264 mm
| 10 3/8” mm
542 mm | 21 3/8” mm
526 mm
| 22 3/4”
Ø 6-12 mm
542 mm | 21 3/8” mm
302 mm
| 22 7/8”
Ø 60 mm | 2 3/8”76 mm | 3” optionalØ
582 mm | 22 7/8”
470 mm
| 18 1/2”
Ø 60 | 2 3/8”
582 mm | 22 7/8”
526 mm
| 22 3/4”
685 mm | 27”
121 mm
| 4 3/4”
542 | 21 3/8” mm
526 mm
| 22 3/4”
542 mm | 21 3/8” mm
264 mm
| 10 3/8” mm
542 mm | 21 3/8” mm
526 mm
| 22 3/4”
Ø 6-12 mm
542 mm | 21 3/8” mm
302 mm
| 22 7/8”
Ø 60 mm | 2 3/8”76 mm | 3” optionalØ
ITALO URBAN 2 MAIN CHARACTERISTICS
Applications: Street and urban lighting.
Optic:STE-M/S: Asymmetrical optic for street lighting - subur-ban application (0F).STU-M/S: Asymmetrical optic for street and cycle path lighting - urban application (0F2H1).STW: Asymmetrical optic for wide roads and wet asphalts (0F).Colour temperature: 4000K (optional 3000K).CRI > 70.Photobiological safety class: EXEMPT GROUP.CIE Photometrical classification: Semi cut-off.IES Photometrical classification: Full cut-off.LED source efficiency: 130lm/W @ 700mA, Tj=85°C, 4000K.
Insulation class: II (I optional).
Protection degree: IP66.Impact protection: IK 08.
LED modules: removable
Tilt angle: Post-top: 0°, +5°, +10°, +15°, +20°. Bracket: 0°, -5°, -10°, -15°, -20°.
Weight: 11,5 kg
Exposed surface: Side: 0.06m2. | Top: 0.25m2.
Mounting: Bracket or Post-top Ø33mm ÷ Ø60mm. | Ø60mm ÷ Ø76mm (optional).
Gear tray: Removable plate
Main reference standards: EN 60598-1, EN 60598-2-3, EN 62471, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3.
Italo urban 2LED LIGHTINGmodel Italo Urban19
Note: The characteristics of the product listed above are subjected to change. They will have to be confirmed in case of order. Values indicated in this technical sheet are to be considered rated values subject to a toler-ance of +/-5%.
Data listed above are subject to change without notice.1: Rated data obtained in laboratory.2: Rated data extrapolated from LED manufacturer datasheet.
18
mountings
Luminaire Flux¹(Ta=25°, 4000K, lm)
modules525mA 700mA
STE-M/STE-S/STW Optic
1 1400 1840
2 2940 3690
3 4410 5540
4 5870 7370
LED S Optic
10 1630 2050
20 3270 4110
30 4810 6070
Rated LED Flux²(Ta=25°, 4000K, lm)
525mA 700mA
STE-M/STE-S/STW Optic
1814 2239
3628 4478
5442 6717
7256 8956
STU-M/STU-S/SV Optic
2010 2550
4020 5100
6030 7650
Rated Luminaire Power¹(Ta=25°, VIN=230 Vac, W)³
modules525mA 700mA
STE-M/STE-S/STW Optic
1 14 20
2 30 40
3 45 59
4 59 79
LED S Optic
10 18 22
20 35 45
30 53 69
Rated LED Power²(Ta=25°, 4000K, lm)
525mA 700mA
STE-M/STE-S/STW Optic
13 17
26 34
39 51
52 69
S Optic
14 20
29 39
43 59
The tables below describe the flux and output power of the available versions. These parameters are nec-essary in order to guarantee a correct comparison of the luminaire performance. In particular, the lumi-naire efficiency (expressed in lm/W) must be calculated as the ratio between the output luminous flux of the luminaire and the power absorbed by the input power supply unit. For the sake of completeness the tables also show the data of the nominal flux and power of the used LED.
ELECTRICAL CHARACTERISTICS
• Power supply:110÷277V - 50/60Hz.
• LED current: 525/700mA.
• Power Factor: >0.9 (at full load).
• Connection for cables featured by a maximum cross section of 4mmq.
• Optional fuse
• Optical unit lifetime525mA:>70.000hr B20L80(included critical failures);>90.000hr L80, TM-21;700mA:>50.000hr B20L80(included critical failures);>70.000hr L80, TM-21.
• Available dimming options:DA: automatic dimming.DAC: customizable DAprofile.PLM: power linecommunication light fluxadjustment.
Installation rep.L/H
H
L1.25
STU-M
S
H
L1 STU-M
STU-M
S
H
L0.75 STU-S
STU-S
S
H
L0.5
STU-S
S
UNI EN 13201Lighting categories
CEO
ME1
CE
1
ME2
CE
2
ME3
CE
3
ME4
CE4
ME5
CE
5
ME6
CE
6
S1 S2 S3 S4 S5 S6
MEW 1
MEW 2
MEW 3
MEW 4
MEW 5
Street Application Cycle path ApplicationStreet Application
WET Class
SELECTION OF THE OPTICS ACCORDING TO UNI EN 13201 LIGHTING CATEGORIES
ITALO 2 URBAN TP ITALO 2 URBAN TP
582 mm | 22 7/8”
470 mm
| 18 1/2”
Ø 60 | 2 3/8”
582 mm | 22 7/8”
526 mm
| 22 3/4”
685 mm | 27”
121 mm
| 4 3/4”
542 | 21 3/8” mm
526 mm
| 22 3/4”
542 mm | 21 3/8” mm
264 mm
| 10 3/8” mm
542 mm | 21 3/8” mm
526 mm
| 22 3/4”
Ø 6-12 mm
542 mm | 21 3/8” mm
302 mm
| 22 7/8”
Ø 60 mm | 2 3/8”76 mm | 3” optionalØ
582 mm | 22 7/8”
470 mm
| 18 1/2”
Ø 60 | 2 3/8”
582 mm | 22 7/8”526 m
m | 22 3/4”
685 mm | 27”
121 mm
| 4 3/4”
542 | 21 3/8” mm
526 mm
| 22 3/4”
542 mm | 21 3/8” mm264 m
m | 10 3/8” m
m
542 mm | 21 3/8” mm
526 mm
| 22 3/4”
Ø 6-12 mm
542 mm | 21 3/8” mm
302 mm
| 22 7/8”
Ø 60 mm | 2 3/8”76 mm | 3” optionalØ
ITALO URBAN TP MAIN CHARACTERISTICS
Applications: Street and urban lighting.
Optic: STU-M/S: Asymmetrical optic for street and cycle path lighting - urban application (0F2H1).S: roto-symmetrical optic for parking and urban areas lighting (0H).Colour temperature: 4000K (optional 3000K).CRI > 70.Photobiological safety class: EXEMPT GROUP.CIE Photometrical classification: Semi cut-off.IES Photometrical classification: Full cut-off.LED source efficiency: 130lm/W @ 700mA, Tj=85°C, 4000K.
Insulation class: II (I optional).
Protection degree: IP66.Impact protection: IK 08.
LED modules: removable
Tilt angle: Post-top: 0°, +5°, +10°, +15°, +20°. Bracket: 0°, -5°, -10°, -15°, -20°.
Weight: 12 kg
Exposed surface: Side: 0.06m2. | Top: 0.25m2.
Mounting: Post-top Ø60mm
Gear tray: Removable plate
Main reference standards: EN 60598-1, EN 60598-2-3, EN 62471, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3.
Italo urban TPLED LIGHTINGmodel Italo Urban2120
Note: The characteristics of the product listed above are subjected to change. They will have to be confirmed in case of order. Values indicated in this technical sheet are to be considered rated values subject to a toler-ance of +/-5%.
Data listed above are subject to change without notice.1: Rated data obtained in laboratory.2: Rated data extrapolated from LED manufacturer datasheet.
0
5
10
15
20
1
2
3
4
5
6
7
[m] [ft]
0
5
10
15
1
2
3
4
5
[m] [ft]6
0
5
10
15
20
[ft]
1
2
3
4
5
6
7
[m]
0
5
10
15
[ft]
1
2
3
4
5
6[m]
LED LIGHTINGmodel Italo Urban
MOUNTINGS
2524
Colour: BlackCode: BKT
Colour: GrayCode: GYT
Colour: WhiteCode: WHT
Colour: YellowCode: YLT
Colour: RedCode: RDT
Colour: BlueCode: BUT
Colour: TealCode: TET
Colour: SilverCode: SLT
Colour: GreenCode: GNT
...and much more is available
LED LIGHTINGmodel Italo Urban
Colours
Italo Urban is available in a range of standard and non-standard colors.
DDL8 - 8 step powder-coat processwith phosphochromate dipping resistant to corrosive and saline environments
Stage 1 Alk Clean
Stage 2 Rinse
Stage 3 Rinse
Stage 4 Chrome Phos
Stage 5 Rinse
Stage 6 Seal
Stage 7 Recirc DI
Stage 8 Fresh DI
Aluminum, like many non-ferrous and plas-tic substrates, requires a mild microscopic surface etch prior to coating to promote im-proved adhesion. This can be accomplished simply and safely, with the right chemistry additives in your pretreatment chemistry. The industry standard chemistries used to micro-scopically etch aluminum have been primari-ly acids such as Phosphoric, Sulfuric or Chro-mic acids, many times used in combination, somewhere in the pretreatment process with a fluoride containing additive to promote the etch. Sigma uses the highest standard chem-icals enviro-friendly to achieve the best pos-sible results.
The Seal is many times the last process ap-plied prior to a low conductivity, Deionized, Distilled or Reverse Osmosis conditioned wa-ter rinse. The purpose of the Seal process is to completely passivate and seal any micro-scopic voids on the surface from the environ-ment prior to coating. This helps to addition-ally improve adhesion and inhibit corrosion. The Seal process can be accomplished in many ways with today’s technological ad-vancements. In some of the latest pretreat-ment technologies, the seal and passivation steps are accomplished in a single step during the conversion coating application process. Tri-valent chrome (which is thought to be a safe alternative to the hexavalent chrome), non-chromic seal such as molybdate and other organic, inorganic and nano-polymer products are used depending on an applica-tion.
2726
AEC LIGHTING 2455 Dixie Rd.Mississauga - ON L4Y 2A1Canada
Web: www.aeclighting.comTEL +1647 247 1680
28
© 2008-2009 Sigma-Lux Group Corp. Not to be reproduced wholly or in part without written permission.