IG – SCWSelf – Contained Water Cooled

Full Height Doored Medium Temperature

Multideck

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June 2020

Page 2: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Page 02 of 13

CA

BIN

ET

TEC

HN

ICA

L D

ATA

Multi Deck Full Height Medium Temperature

Cabinet Type:

Model Designation:

Document Issue:

Self – Contained Water

IG - SCW

(01) 31st January 2020

Contents:

Section 01. Cabinet Technical Data – pages 3&4

Section 02. Cabinet Side View - page 5

Section 03. Cabinet Plan View - Drain & Foot Locations – page 6

Section 04. Cabinet Plan View - Condensing Unit s & Electrical Control Panel Location – page 7

Section 05. Cabinet Side View Back To Back Island – page 8

Section 06. Control Panel - Electrical Schematic – page 9

Section 07. Electrical Wiring Cabinet Loom – page 10

Section 08. Kick Plate Assembly Connections To Electrical Control Panel – page 11

Section 09. Condensate Pump Alarm Cable Connections To Electrical Control Panel - page 12

Section 10. Temperature Air ‘Return’ & ‘Discharge’ Probe Locations – page 13

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June2020

Page 3: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Product Type Meat /Dairy

Maximum Design Ambient 75°F @ 55% RH

Case Length 12’(6 door)

8’(4 door)

6’(3 door)

4’(2 door)

Refrigeration Data – Water Cooled Charge Amounts

Refrigerant Charge per Cabinet (R449A)

1390 grms49 oz

3.06 lb3 lb 1 oz

1190 grms42 oz

2.63 lb2 lb 10 oz

1500 grms53 oz

3.31 lb3 lb 5 oz

1190 grms42 oz

2.63 lb2 lb 10 oz

TXV Orifice size 01 00 00 00

Electrical Data (115v 60 Hz) (Hot , Neutral & Ground) Amps Amps Amps Amps

Fan Motors (EC) 0.42 0.28 0.21 0.14

Compressor Cooling Fan Motors (EC) 0.18 0.18 0.18 0.1.8

Lights (LED) : Doors only 0.97 0.7 0.55 0.41

Controller 0.08 0.08 0.08 0.08

Kick Plate Fans 0.52 0.32 0.37 0.16

Trim Heaters N/A N/A N/A N/A

Condensate Pump (where fitted) 0.08 0.08 0.08 0.08

Electrical Data (208v 60 Hz) ( 2 Hots & Ground) Amps Amps Amps Amps

Condensing Unit 8.8 6.5 6.5 5.6

Defrost Heaters N/A N/A N/A N/A

Combined Single Point Load (MCA – Ref) 12.5 9.01 9.01 7.59

MOPD 15 15 15 15

Miscellaneous Data

Total Heat Rejection (THR) (BTU/hr) 13989 10407 10407 8352

Total Heat Rejection (THR) To Air (BTU/hr) 1024 1024 1024 1024

Total Heat Rejection (THR) To Water (BTU/hr) 12966 9383 9383 7329

Evaporator Case Load THR (BTU/hr) (10°F) 6448 4299 3207 2149

Pressure Drop (psi) 1.27 1.27 1.27 1.27

Total Internal Volume Cu.ft 110 73 55 37

Water INLET Temperature (°F)Optimum Range 65 to 105 - Max Limit 105

Water OUTLET Temperature (°F) Optimum Range 75 to 115 - Max Limit 115

Electrical Connection Top left hand side of case – see plan drawing page 7 for location

Drainage Connection 40mm (1 9/16”) Outlet reducing to 25mm (1”) – see plan drawing page 6 for quantity and location

Note: Specific Heat of Glycol @ 105 °F KJ/Kg – K 4.0425

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June 2020

Page 03 of 13Section 01. Cabinet Technical Data Sheet: IG - SCW - TXV

Page 4: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Set – Up Data Meat Dairy

Set Point Temperature (cut in) (F°) 34 36

Differential (below) (F°) 6 4

Evaporating Temperature - Calculated (F°) 23 25

Cabinet Temperature Ratio (air on %) 100 100

Anti – cycle Time (seconds) 180 180

No. Defrosts (per 24hrs) 6 6

Maximum Defrost Time (minutes) 45 45

Defrost Termination Temperature (air off) (F°) 47 47

Drain Down Time (mins) 1 1

Fans in Defrost ON ON

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29-June 2020

Page 04 of 13Section 01. Cabinet Technical Data Sheet: ID – SCW - TXV

Case Length 12’ (6 door) 8’ (4 door) 6’ (3 door) 4’ (2door)

Fan Speed

Evaporator: Run State (RPM) 1300 1300 1300 1300

Evaporator: Defrost (RPM) 1300 1300 1300 1300

Compressor Hitachi Hitachi Hitachi Hitachi

Make & modelZS1120X1

(1.5 H.P)1 off

ZS7516X1(1 HP )

1 off

ZS7516X1(1 HP)1 off

ZS6013X1(0.75 HP )

1 off

Start Capacitor Size (per compressor charger box) 60µF / 450V 40µF / 450V 40µF / 450V 40µF / 450V

Run Capacitor Size (per compressor charger box) 45µF / 450V 30µF / 450V 30µF / 450V 30µF / 450V

Pressure Switch High Pressure Low Pressure

Open (PSI) 410 3

Close (PSI) 310 15

Temperature Sensor

Make & Model CPC 10k

Typical Air Flow At Honeycomb

Air Flow (CuFt /min) 1695 1695 1695 1695

Page 5: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June 2020

Page 05 of 13

Section 02. Cabinet Side View Drawing IG - SCW

Drawing Measurements

Inches Metric Millimetres

Side Profile View

Page 6: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Page 06 of 13

Drawing Measurements

Imperial Inches Metric Millimetres

Section 03. Cabinet Plan View Showing Drain & Foot Locations IG - SCW

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June 2020

Base Plans

Page 7: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Page 07 of 13

Drawing Measurements

Imperial Inches Metric Millimetres

Section 04. Cabinet Plan View Showing Cond. Assy& Electrical Tray Locations IG - SCW

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June 2020

Top Plans

Page 8: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Page 08 of 13Section 05. Cabinet Side View Showing Cabinet

Back To Back Island IG - SCW

Drawing Measurements

Imperial Inches Metric Millimetres

Back to Back Island Side View

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June 2020

Page 9: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June 2020

Page 09 of 13

*

Ple

ase

note

: Sam

e s

chem

atic

with O

R w

ithout

condensa

te p

um

p

Section 06. Control Panel - Electrical Schematic IG - SCW

Page 10: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June 2020

Page 10 of 13

Fan Baffle Assembly

Condensate Pump Link Cable

LIGHTS

FANS

PUMP PUMP

L1

NE

E2

1

2

WIRING KEY

LIVE L (1)NEUTRAL N (2)EARTH E (GREEN/YELLOW)

Fan lead wiring color :

White (Live), Green (Neutral) Cut back spare wire (Brown)

Section 07. Electrical Wiring Cabinet Loom IG - SCW

Page 11: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June 2020

Page 11 of 13

Section 08. Kick Plate Assembly Connections to Electrical Control Panel IG - SCW

Section plan view: Electrical Control Panel

A

Electrical control panel location

Page 12: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June 2020

Page 12 of 13

Section 09. Condensate Pump Alarm Cable Connections to Electrical Control Panel IG - SCW

Pump CableCabinet Loom ALM0199

Discharge Hose

Elec

tric

al C

on

nec

tio

n: c

on

den

sate

pu

mp

to

ca

bin

et lo

om

Plan View CONDENSATE PUMP

BLACK : Common

YELLOW: Closed during standby or mains

OFF

RED: Closed during alarm condition

Heat shrink

Alarm Extension Cable

Cables connected to alarm extension cable at

Carter Retail Equipment Ltd

BLACK : (No 2) =

RED : Closed during

alarm condition

BLACK : (No 1) =

BLACK : Common

EARTH : =

YELLOW :

Closed during

standby or

mains OFF

Cut back the EARTH & heat shrink cable

BLACK : (No 1) (common)

BLACK : (No 2) (closed

during alarm condition)

BLACK : (No 1) (common)

Alarm Link Cables

Plan View

Inside Electrical

Control Panel

ORANGE : BL10 Plug & Socket

connection to electrical control panel

Return (air on) probe from cabinet

Discharge (air off) probe from cabinet

BLACK : (No 2) (closed

during alarm condition)

Electrical control panel location

Condensate Pump ALARM cable

Page 13: IG - SCW Technical Data Sheet issue 02 June 29th 2020

Contact Telephone: +44 121 250 1111 IG - SCW Technical Data Sheet Issue 02 29th June 2020

Page 13 of 13

Section 10. Temperature Air ‘ON’ & ‘OFF’ Probe Locations IG - SCW

Side View Front View

Air Discharge

Probe 2

Air Return

Probe 1

Air

Dis

ch

arg

e P

rob

e 2

Air

Re

turn

Pro

be 1

Probes Fitted To

LHS of Cabinet