    TABLE OF CONTENTS1.0 INTRODUCTION .............................................................................................. 31.1. DOCUMENTATION SCOPE AND UPDATES .................................................................31.2. OVERVIEW .......................................................................................................32.0 HARDWARE INSTALLATION .............................................................................. 42.1. INSTALLATION IN A CALISTO/CALISTO 2 ...............................................................42.2. INSTALLATION IN A CALISTO 5/CALISTO 9 ............................................................73.0 IP CONFIGURATION .......................................................................................10

    REVISION 3

  • PAGE 2

    LIST OF FIGURESFIGURE 1: INSTALLATION OF THE STANDOFFS .....................................................................5FIGURE 2: J9 CONNECTOR AND INSERTION HOLES - CALISTO/CALISTO 2 .................................5FIGURE 3: INSERTING THE PCB INTO THE J9 CONNECTOR .....................................................6FIGURE 4: DISCONNECTING THE ETHERNET PATCH CABLE .....................................................6FIGURE 5: CONNECTING THE ETHERNET PATCH CABLE INTO THE IEC 61850 PCB - CALISTO (C76)/CALISTO 2 (C85) ......................................................................................7FIGURE 6: CONNECTING THE ETHERNET PATCH CABLE INTO THE IEC 61850 PCB - CALISTO (C76A)/CALISTO 2 (C85A) ..................................................................................7FIGURE 7: INSTALLATION OF THE STANDOFFS .....................................................................8FIGURE 8: J2 CONNECTOR AND INSERTION HOLES - CALISTO 5/CALISTO 9 ...............................8FIGURE 9: DISCONNECTING THE ETHERNET PATCH CABLE .....................................................9FIGURE 10: CONNECTING THE ETHERNET PATCH CABLE INTO THE IEC 61850 PCB - CALISTO 5/CALISTO 9 ....................................................................................................9FIGURE 11: CONTROL PANEL .........................................................................................11FIGURE 12: CONTROL PANEL > SYSTEM AND SECURITY .......................................................11FIGURE 13: WINDOWS FIREWALL > ALLOWED PROGRAMS ...................................................12FIGURE 14: WINDOWS FIREWALL > ADD A PROGRAM .........................................................12FIGURE 15: CALISTO IEC 61850 CONFIG > SEARCHING .......................................................13FIGURE 16: CALISTO IEC 61850 CONFIG > IP CONFIGURATION ............................................13FIGURE 17: IP CONFIGURATION > DIALOG .......................................................................14FIGURE 18: IP CONFIGURATION > UPDATE AND REBOOT .....................................................14FIGURE 19: CALISTO IEC 61850 CONFIG ..........................................................................15

  • PAGE 3

    1.0 INTRODUCTION

    1.1. DOCUMENTATION SCOPE AND UPDATES

    This Installation and Configuration Manual provides information on how to install the IEC 61850 Communication Kit hardware and how to configure the kit using the provided software (IEC61850Config.exe). It can be installed with any of the following Calisto models:

    Calisto (C76 & C76A)

    Calisto 2 (C85 & C85A)

    Calisto 5 (C500)

    Calisto 9 (C900 & C900S)

    NOTICE

    The IEC 61850 Communication Kit is supported by the following versions of the Calisto Access and Calisto Manager software: Calisto Access: firmware version v2.63 and later Calisto Manager: version 0.0.7 and later

    An electronic version of this document is available on the CD supplied with the IEC 61850 Communication Kit.

    1.2. OVERVIEW

    The IEC 61850 Communication Kit allows the Calisto monitor to communicate through the IEC 61850 protocol. The kit includes the following items:

    Item Description For stepBCAL-0222 IEC 61850 Communication PCB 2.0 Hardware Installation

    CBL-00003 CAT 5e crossover patch cable 3 ft. 3.0 IP Configuration

    ZNS-00108 IEC 61850 Configuration CD 3.0 IP Configuration

    ZNS-00107 IEC 61850 Installation & Configuration Manual

    The configuration of the IEC 61850 Communication Kit requires the following param-eters: a suitable fixed IP address, a subnet mask and a default gateway. If necessary, refer to your network administrator to obtain these parameters.

  • PAGE 4

    Please consult the Device Profile document specific to your Calisto model to interpret the protocol mapping of the IEC 61850 Communication Kit. The Device Profile docu-ments are included on the CD supplied with the kit.

    2.0 HARDWARE INSTALLATION

    WARNING

    The mains supply switch of the monitor or the dedicated circuit breaker must be shut off before proceeding with the installation of the IEC 61850 Communication Kit. Refer to the Installation & Operation Manual of your Calisto monitor to understand all associated hazards.

    CAUTION

    It is recommended to safely disconnect any hazardous cir-cuits from the alarm relays of the Calisto monitor.

    This present section, 2.0 Hardware Installation, should be skipped if the IEC 61850 Communication PCB is factory installed in the Calisto monitor. Go straight to Section 3.0 to configure the IEC 61850 Communication Kit.

    To install the kit in a Calisto/Calisto 2 monitor, go to Section 2.1.

    To install the kit in a Calisto 5/Calisto 9 monitor, go to Section 2.2.

    2.1. INSTALLATION IN A CALISTO/CALISTO 2

    STEP 1: Before installing the kit, it is recommended to download the latest Calisto Access or Calisto Manager software from www.morganschaffer.com.

    STEP 2: Turn OFF the Calisto/Calisto 2 monitor using the mains switch.

    STEP 3: Open the door of the monitor.

    STEP 4: Remove the IEC 61850 Communication PCB from the antistatic bag by hold-ing it by its edges.

  • PAGE 5

    STEP 5: If it has not already been done, install the nylon standoffs in the PCB by inserting the shorter ends of the standoffs into the two holes of the PCB (see Figure 1).

    STEP 6: Locate the J9 connector and the two insertion holes on the Main I/O PCB (see Figure 2).

    Figure 1: Installation of the standoffs

    Figure 2: J9 connector and insertion holes - Calisto/Calisto 2

  • PAGE 6

    STEP 7: Gently insert the PCB into the J9 connector. The nylon standoffs should easily snap into the holes (see Figure 3).

    STEP 8: To complete the installation, follow the instructions specific to the model of your Calisto:

    CALISTO (C76)/CALISTO 2 (C85) ONLY (WITH 1 ETHERNET CABLE)

    Unplug the Ethernet patch cable from the CPU board (see Figure 4), and plug it into the IEC 61850 Communication PCB (see Figure 5).

    Figure 3: Inserting the PCB into the J9 connector

    Figure 4: Disconnecting the Ethernet patch cable

  • PAGE 7

    CALISTO (C76A)/CALISTO 2 (C85A) ONLY (WITH 2 ETHERNET CABLES)

    Leave the blue Ethernet patch cable connected in its port on the CPU board, and plug the yellow Ethernet patch cable labelled IEC 61850 into the IEC 61850 Communication PCB (see Figure 6).

    2.2. INSTALLATION IN A CALISTO 5/CALISTO 9

    STEP 1: Before installing the kit, it is recommended to download the latest Calisto Manager software from www.morganschaffer.com.

    STEP 2: Turn OFF the Calisto 5/Calisto 9 monitor using the mains switch.

    Figure 5: Connecting the Ethernet patch cable into the IEC 61850 PCB -

    Calisto (C76)/Calisto 2 (C85)

    Figure 6: Connecting the Ethernet patch cable into the IEC 61850 PCB -

    Calisto (C76A)/Calisto 2 (C85A)

  • PAGE 8

    STEP 3: Open the door of the monitor.

    STEP 4: Remove the IEC 61850 Communication PCB from the antistatic bag by hold-ing it by its edges.

    STEP 5: If it has not already been done, install the nylon standoffs in the PCB by inserting the shorter ends of the standoffs into the two holes of the PCB (see Figure 7).

    STEP 6: Locate the J2 connector and the two insertion holes on the Main I/O PCB (see Figure 8).

    Figure 7: Installation of the standoffs

    Figure 8: J2 connector and insertion holes - Calisto 5/Calisto 9

  • PAGE 9

    STEP 7: Gently insert the PCB into the J2 connector. The nylon standoffs should easily snap into the holes.

    STEP 8: Unplug the Ethernet patch cable from the CPU board (see Figure 9), and plug it into the IEC 61850 Ethernet Communication PCB (see Figure 10).

    Figure 9: Disconnecting the Ethernet patch cable

    Figure 10: Connecting the Ethernet patch cable into the IEC 61850 PCB -

    Calisto 5/Calisto 9

  • PAGE 10

    3.0 IP CONFIGURATION

    NOTICE

    For new monitors with a factory installed IEC 61850 Communication Kit, the monitor must be installed before configuring the kit.

    Configure the IEC 61850 Communication Kit right after set-ting the transformer information in either Calisto Manager or Calisto Access.

    The default IP address is 192.168.0.121 (or previously, 10.3.6.89), and the Subnet Mask is 255.255.0.0.

    STEP 1: Switch ON the mains power of the Calisto monitor and wait approximately 3 minutes.

    STEP 2: Connect the supplied crossover cable between a computer and the Ethernet port on the communication interface board. For models Calisto (C76A) and Calisto 2 (C85A), use the port identified as IEC 61850.

    STEP 3: Insert the supplied CD into the computer and copy the IEC61850Config folder on your computer.

    STEP 4: To make sure that the Calisto IEC 61850 Config (IECConfig.exe) is not blocked by the firewall on port 2500, follow these steps to allow it through the Windows 7 firewall.

    a. Click the Windows Start button, and then Control Panel.

    b. Make sure that View by: Category is selected, and then click on System and Security.

  • PAGE 11

    c. Click Allow a program through Windows Firewall located under Windows Firewall.

    Figure 11: Control Panel

    Figure 12: Control Panel > System and Security

  • PAGE 12

    d. On the Allowed Programs screen, click on the Allow another program... button.

    e. In the Add a program window, click the Browse... button. Then locate IEC61850Config.exe and click the Add button.

    Figure 13: Windows Firewall > Allowed Programs

    Figure 14: Windows Firewall > Add a Program

  • PAGE 13

    f. Locate Calisto IEC 61850 Config in the Allowed Programs panel and select all the check boxes next to it (i.e. Domain, Public, etc.). Click the OK but-ton and close the control panel.

    STEP 5: Double click on the IEC61850Config executable file. The following window will appear:

    STEP 6: The software should detect the unit and show it in the list of devices. If the software does not detect the device, click on Refresh List.

    STEP 7: When the device is detected, click IP Configuration.

    Figure 15: Calisto IEC 61850 Config > Searching

    Figure 16: Calisto IEC 61850 Config > IP Configuration

  • PAGE 14

    STEP 8: Enter the IP Address, the Subnet Mask and the Default Gateway. Click the Apply button.

    STEP 9: The device is updated with the new configuration and is rebooted.

    Figure 17: IP Configuration > Dialog

    Figure 18: IP Configuration > Update and Reboot

  • PAGE 15

    STEP 10: The main window then shows the devices list with the new configuration.

    STEP 11: Disconnect and remove the crossover patch cable, and connect the monitor to the network using a non-crossover LAN cable.

    STEP 12: Close and tighten the door of the monitor.

    Figure 19: Calisto IEC 61850 Config

  • www.morganschaer.com | Support: + 001.514.739.1967

    8300 Saint-Patrick, Suite 150, LaSalle, Quebec Canada H8N 2H1T: +001.514.739.1967 | F: +001.514.739.0434 | E: [email protected]

    1.0INTRODUCTION1.1.Documentation Scope and Updates1.2.Overview

    2.0Hardware Installation2.1.Installation in a Calisto/Calisto 22.2.Installation in a Calisto 5/Calisto 9

    3.0IP ConfigurationFigure 1: Installation of the standoffsFigure 2: J9 connector and insertion holes - Calisto/Calisto 2Figure 3: Inserting the PCB into the J9 connectorFigure 4: Disconnecting the Ethernet patch cableFigure 5: Connecting the Ethernet patch cable into the IEC 61850 PCB -Calisto (C76)/Calisto 2 (C85)Figure 6: Connecting the Ethernet patch cable into the IEC 61850 PCB -Calisto (C76A)/Calisto 2 (C85A)Figure 7: Installation of the standoffsFigure 8: J2 connector and insertion holes - Calisto 5/Calisto 9Figure 9: Disconnecting the Ethernet patch cableFigure 10: Connecting the Ethernet patch cable into the IEC 61850 PCB -Calisto 5/Calisto 9Figure 11: Control PanelFigure 12: Control Panel > System and SecurityFigure 13: Windows Firewall > Allowed ProgramsFigure 14: Windows Firewall > Add a ProgramFigure 15: Calisto IEC 61850 Config > SearchingFigure 16: Calisto IEC 61850 Config > IP ConfigurationFigure 17: IP Configuration > DialogFigure 18: IP Configuration > Update and RebootFigure 19: Calisto IEC 61850 Config