Page 1: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

One Stop Virtualization Shop

StarWind Virtual SAN®

Hyperconverged

2-Node Scenario

with Hyper-V Server 2016 FEBRUARY 2018

TECHNICAL PAPER

Page 2: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 2

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Trademarks

“StarWind”, “StarWind Software” and the StarWind and the StarWind Software logos are registered

trademarks of StarWind Software. “StarWind LSFS” is a trademark of StarWind Software which may be

registered in some jurisdictions. All other trademarks are owned by their respective owners.

Changes

The material in this document is for information only and is subject to change without notice. While

reasonable efforts have been made in the preparation of this document to assure its accuracy, StarWind

Software assumes no liability resulting from errors or omissions in this document, or from the use of the

information contained herein. StarWind Software reserves the right to make changes in the product design

without reservation and without notification to its users.

Technical Support and Services

If you have questions about installing or using this software, check this and other documents first - you will

find answers to most of your questions on the Technical Papers webpage or in StarWind Forum. If you need

further assistance, please contact us.

About StarWind

StarWind is a pioneer in virtualization and a company that participated in the development of this

technology from its earliest days. Now the company is among the leading vendors of software and hardware

hyper-converged solutions. The company’s core product is the years-proven StarWind Virtual SAN, which

allows SMB and ROBO to benefit from cost-efficient hyperconverged IT infrastructure. Having earned a

reputation of reliability, StarWind created a hardware product line and is actively tapping into

hyperconverged and storage appliances market. In 2016, Gartner named StarWind “Cool Vendor for

Compute Platforms” following the success and popularity of StarWind HyperConverged Appliance. StarWind

partners with world-known companies: Microsoft, VMware, Veeam, Intel, Dell, Mellanox, Citrix, Western

Digital, etc.

Copyright ©2009-2018 StarWind Software Inc.

No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by

any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent

of StarWind Software.

Page 3: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 3

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Contents

Introduction .......................................................................................................................................................... 4

Solution Diagram ................................................................................................................................................. 5

Pre-Configuring the Servers ............................................................................................................................. 6

Downloading, Installing, and Registering the Software .............................................................................. 9

Configuring Shared Storage ........................................................................................................................... 15

Extending StarWind Device ............................................................................................................................. 28

Discovering Target Portals .............................................................................................................................. 30

Connecting Targets ........................................................................................................................................... 34

Multipath Configuration .................................................................................................................................. 39

Creating a Cluster .............................................................................................................................................. 42

Conclusion .......................................................................................................................................................... 46

Page 4: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 4

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Introduction

StarWind Virtual SAN® is a native Windows hypervisor-centric hardware-less VM

storage solution. It creates a fully fault-tolerant and high performing storage pool built

for the virtualization workloads by mirroring existing server’s storage and RAM

between the participating storage cluster nodes. The mirrored storage resource is

then connected to all the cluster nodes and treated just as local storage by all

hypervisors and clustered applications. High Availability is achieved by providing the

multipath access to all storage nodes. StarWind Virtual SAN delivers supreme

performance compared to any dedicated SAN solution since it runs locally on the

hypervisor and all I/O is processed by local RAM, SSD cache, and disks. This way it

never gets bottlenecked by storage fabric.

This guide is intended for experienced Windows Server users or system

administrators. It provides the detailed instructions on how to setup a 2-node

Hyperconverged Hyper-V 2016 Cluster with StarWind Virtual SAN as a storage

provider.

A full set of up-to-date technical documentation can always be found here, or by

pressing the Help button in the StarWind Management Console.

For any technical inquiries please visit our online community, Frequently Asked

Questions page, or use the support form to contact our technical support department.

Page 5: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 5

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Solution Diagram

The diagram bellow illustrates the network and storage configuration of the resulting solution

described in this guide.

Page 6: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 6

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Pre-Configuring the Servers

1. Enable Remote Desktop to the servers.

2. Join the servers to the domain.

Rename and adjust static IPs for all NICs. To do so, perform the steps 3-6 below:

3. Run powershell.exe in the Command Prompt to check the network adapters availability

in the system:

Get-NetAdapter

Page 7: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 7

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

4. To change the name and set the static IP for Heartbeat/Sync channel, type the next

command in the PowerShell console:

Get-NetAdapter “Ethernet2” | Rename-NetAdapter –NewName “Sync” Get-NetAdapter “Sync” | New-NetIPAddress –IPAddress 172.16.20.10 –PrefixLength 24

5. Alternatively, the network settings can be changed through the sconfig.cmd window. In

Network Settings (option 8), select the Index of the NIC, which should serve as a

synchronization link:

The following actions are possible:

• Set Network Adapter Address – selection between DHCP or Static IP

• Set DNS Servers – providing DNS settings

• Clear DNS Server Settings

• Return to Main Menu

6. Disable Firewall on each server via PowerShell:

Get-NetFirewallProfile | Set-NetFirewallProfile –Enabled False

Page 8: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 8

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

7. It is highly recommended to enable Jumbo packets (9014) on the Sync and iSCSI

networks. This can be done via PowerShell in two ways.

Directly on the Sync/iSCSI NIC: Set-NetAdapterAdvancedProperty –Name “Sync” –RegistryKeyword “*JumboPacket” –Registryvalue 9014 Set-NetAdapterAdvancedProperty –Name “iSCSI” –RegistryKeyword “*JumboPacket” –Registryvalue 9014

For all NICs available in the system: Set-NetAdapterAdvancedProperty –Name “*” –RegistryKeyword “*JumboPacket” –Registryvalue 9014

8. Ping each node with Jumbo packets (change the asterisk to the partner node’s IP

address):

ping 172.16.20.* -f –l 8900 for Sync

ping 172.16.10.* -f –l 8900 for iSCSI

9. Install Failover Clustering and Multipath I/O features on both servers using PowerShell:

Install-WindowsFeature Failover-Clustering –IncludeAllSubFeature –Restart Enable-WindowsOptionalFeature –Online –FeatureName MultiPathIO Enable-MSDSMAutomaticClaim –BusType iSCSI

10. Create a Virtual Switch via PowerShell:

New-VMSwitch –Name “vSwitch” –NetAdapterName “management”

NOTE: The Virtual Switch name must be the same on both nodes.

Page 9: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 9

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

11. Create Local Partition for the Storage drive. In the CMD window, run the following:

Diskpart list disk

select disk X where X is the number of the disk to be processed online disk attributes disk clear readonly convert GPT create partition Primary

format fs=ntfs label=X quick where X is the name for the Volume list volume select volume X

assign letter X where X is the letter for the Volume list Volume

Any of the arrays to be used by StarWind Virtual SAN for storing virtual disk images should meet

the following requirements:

• Initialized as GPT

• Have a single NTFS-formatted partition

• Have a drive letter assigned

Downloading, Installing, and Registering the Software

12. Download the StarWind VSAN software by following the link:

https://www.starwindsoftware.com/registration-starwind-virtual-san

13. Copy the StarWind VSAN installer to both Hyper-V Server instances. Launch the

downloaded installer on the server where StarWind Virtual SAN or one of its components

needs to be installed. The Setup Wizard will appear. Click Next to continue.

Page 10: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 10

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

14. Read and accept the License Agreement. Click Next to continue.

15. Carefully read the information about new features and improvements. Red text indicates

warnings for users who are updating existing software installations. Click Next to

continue.

Page 11: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 11

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

16. Click Browse to modify the installation path if necessary. Click Next to continue.

17. Select the required deployment scenario for StarWind VSAN.

This installation type is designed for GUI-less OS editions. The StarWind service is the “core” of

the software. It can create iSCSI targets as well as share virtual and physical devices. The service

can be managed by StarWind Management Console from any Windows computer on the

network that has StarWind Management Console installed (GUI required). Click Next to

continue.

Page 12: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 12

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

18. Specify the Start Menu Folder. Click Next to continue.

19. When the license prompt appears, request a time-limited fully functional evaluation key,

or a FREE version key, or use the commercial license key obtained with the purchase of

StarWind Virtual SAN by selecting the corresponding option. Click Next to continue.

Page 13: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 13

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

20. Click on the Browse button to locate the license file. Clink Next to continue.

21. Review the licensing information. Click Next to continue.

Page 14: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 14

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

22. Verify the installation settings. Click Back to make any changes. Click Install to continue.

23. Click Finish to close the wizard.

Repeat the steps 13-24 on the partner node.

To manage StarWind Virtual SAN deployed on the OS edition with no GUI enabled, StarWind

Management Console should be installed on a computer that runs the GUI-enabled Windows

edition.

Page 15: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 15

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Configuring Shared Storage

24. Run StarWind Management Console from the GUI-enabled Windows OS. Press Add

Server.

25. Type the management IP for your Hyper-V Server 2016. Add both StarWind servers.

Otherwise, type in the StarWind servers’domain names. Click OK to continue.

Page 16: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 16

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

26. Connect to your servers and specify the path for the storage pool.

Press Yes to configure the storage pool. If the storage pool destination needs to be changed,

press Choose path… and point the file browser to the necessary disk.

NOTE: StarWind Management Console will request the default storage pool location on the

server that is connected for the first time. Configure the default storage pool to use one of the

volumes prepared earlier. All the devices created through the Add Device wizard will be stored

there. If an alternative storage path for StarWind virtual disks is needed, the Add Device

(advanced) menu item can be used.

27. Select the StarWind server where the device should be created. Press the Add Device

(advanced) button on the toolbar or right-click on the StarWind server.

Page 17: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 17

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

28. In Add Device Wizard, select Hard Disk Device and click Next to continue.

29. Select Virtual Disk and click Next.

Page 18: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 18

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

30. Specify the name for the StarWind device, its location and size. Click Next.

NOTE: It is recommended to create a 1 GB device to avoid long synchronization process. This

device can be extended after the creation.

31. Specify the vitual disk options. Choose 4096 bytes sector size for Microsoft Windows.

Page 19: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 19

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

32. Define the caching policy and specify the RAM cache size (in MB). Click Next to continue.

33. Define the Flash (L2, SSD) cache parameters and size if necessary. Choose the SSD drive

path using the wizard.

NOTE: It is recommended to put the 1 GB of L1 cache in write-back mode per 1 TB storage

capacity. The recommended size of L2 cache is 10% of the initial StarWind device size.

Page 20: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 20

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

34. Specify the target parameters. Enable the Target Name checkbox to customize the

target name. Otherwise, the name will be generated automatically based on the target

alias. Click Next to continue.

35. Click Create to add a new device and attach it to the target. Then click Close to finish

working with the wizard.

Page 21: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 21

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

36. Right-click on the device that has just been created and select Replication Manager.

37. The Replication Manager window will appear. Press the Add Replica button.

Page 22: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 22

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

38. Select Synchronous two-way replication. Click Next to proceed.

39. The default StarWind management port is 3261. If a different port needs to be

configured, please type it in the Port number field.

Page 23: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 23

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

40. Choose Heartbeat Failover Strategy.

41. Choose Create new Partner Device and click Next.

Page 24: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 24

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

42. Specify the partner device location if necessary. Modify the target name of the device if

required.

43. Select the Synchronization and Heartbeat networks for the HA device. Modify the ALUA

settings if required.

Page 25: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 25

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

44. Click Change network settings and specify the interfaces for Synchronization and

Heartbeat. Click OK and Next.

45. Select Synchronize from existing Device for the partner device initialization mode.

Click Next.

Page 26: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 26

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

46. Press the Create Replica button. Then click Close to exit the wizard.

47. The added devices will appear in the StarWind Management Console.

Page 27: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 27

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

48. Repeat steps 28-47 for the remaining virtual disks that will be used as Cluster Shared

Volumes. Once all devices are created, the Management console should look as

demonstrated in the screenshot below:

Page 28: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 28

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Extending StarWind Device

49. Right-click the StarWind device and choose Extend Size of HA.

50. Specify the Amount of Space to Extend for this device and press Extend to continue.

Page 29: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 29

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

After extension is over, the new size of the StarWind HA device will appear in StarWind

Management Console.

Page 30: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 30

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Discovering Target Portals

This part describes how to connect the previously created disks, which need to be further added

to the cluster servers.

51. In the CMD window, run the following command to start configuring the Microsoft iSCSI

initiator:

iscsicpl

If the dialog below appears, press Yes.

Page 31: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 31

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

52. In the iSCSI Initiator Properties window, click the Discovery tab:

53. Click on the Discover Portal button. In the Discover Target Portal dialog, type in

127.0.0.1 for the portal IP address:

Page 32: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 32

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

54. Click on the Advanced button. Select Microsoft iSCSI Initiator as the Local Adapter

and select the Initiator IP (keep it default for 127.0.0.1). Confirm your actions to complete

the Target Portal discovery.

55. Click on the Discovery Portal button once again and specify the IP address of the

partner’s iSCSI link.

56. In Advanced settings, select Microsoft iSCSI Initiator as the Local Adapter. Select the

Initiator IP in the same subnet as the IP address of the partner server from the step 55.

Confirm your actions to complete the Target Portal discovery.

Page 33: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 33

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

57. The resulting Discovery tab will look as demonstrated in the screenshot below:

58. Complete the steps 52-57 for the other node.

Page 34: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 34

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Connecting Targets

59. Select the Targets tab. Choose the target of the Cluster Shared Volume available from

the local server and click Connect.

60. Enable the checkboxes as in the image below.

Page 35: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 35

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

61. Select Microsoft iSCSI Initiator in the Local adapter dropdown menu. Select 127.0.0.1

for the Target portal IP. Confirm your actions.

62. From the Targets tab, select the Witness target available from the local server and click

Connect. Enable the checkboxes as in the image below:

Page 36: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 36

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

63. In Advanced settings, select Microsoft iSCSI Initiator in the Local adapter dropdown

menu. Set 127.0.0.1 for the Target portal IP. Confirm your actions.

NOTE: Do not connect the partner target for the Witness device available from the other

StarWind node.

64. From the Targets tab, select the partner target from the other StarWind node and click

Connect. Enable checkboxes as in the image below.

Page 37: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 37

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

65. In Advanced settings, select Microsoft iSCSI Initiator in the Local Adapter

dropdown menu. In the Initiator IP dropdown, select the IP address of the host’s iSCSI

link. In Target portal IP, select the corresponding partner’s IP address from the same

subnet. Confirm your actions.

66. The resulting Targets tab will look as demonstrated on the screenshot below:

Page 38: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 38

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

67. Initialize the disks and create the partitions on them using DISKPART. To create a cluster,

the disk devices are required to be visible on both nodes.

Run diskpart in the CMD window:

List disk Select disk X Online disk Clean Attributes disk clear readonly Convert GPT Create Partition Primary

Format fs=ntfs label=X quick where X is the name of the Volume

Do not assign any letter for the cluster disks.

NOTE: It is recommended to initialize the disks as GPT.

68. Perform the steps 59-67 for the other node.

Page 39: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 39

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Multipath Configuration

Configure the MPIO policy for each device, specifying localhost (127.0.0.1) as the active path. To

achieve this, perform the following steps.

69. Select a target located on the local server and click Devices.

Page 40: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 40

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

70. In the Devices dialog, press MPIO.

Page 41: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 41

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

71. Select Least Queue Depth in the Load balance policy dropdown menu.

72. Repeat the steps 69-71 for each device on the current and the second node.

Page 42: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 42

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Creating a Cluster

73. Open the Failover Cluster Manager using the desktop version of Windows or a

different GUI-based Windows Server and click on the Create Cluster link in the Actions

section of Failover Cluster Manger.

Page 43: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 43

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

74. Specify the servers to be added to the cluster. Click Next to continue.

75. Validate the configuration by passing the cluster validation tests: select Yes and Run all

tests. Click Next to continue.

Page 44: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 44

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

76. Specify the cluster name.

NOTE: If the cluster servers get IP addresses over DHCP, the cluster also gets its IP address over

DHCP. If the IP addresses are set statically, you need to set the cluster IP address manually. Click

Next to continue.

77. Make sure that all settings are correct. Use the Previous button to make any changes.

Page 45: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 45

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

NOTE: If the Add all eligible storage to the cluster checkbox is enabled, the wizard will try to

add all disks to the cluster automatically. The smallest device will be assigned as the Witness. It is

recommended to disable this option before you click Next and add Witness manually.

Click Finish to close the wizard.

Page 46: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 46

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Conclusion

Windows Failover Cluster on top of Hyper-V Server 2016 is successfully created. This cluster will

increase the availability of the services or applications on it, as well as exclude the downtime

during the maintenance.

Please note that StarWind does not recommend repeating the steps above as this process

violates the Microsoft license agreement.

In case you have any additional questions, visit our Support Forum.

Page 47: Hyperconverged 2-Node Scenario with Hyper-V Server …Ping each node with Jumbo packets ... Hyperconverged 2-Node Scenario with Hyper-V 2016 28. In Add Device Wizard, select Hard Disk

TECHNICAL PAPER 47

StarWind Virtual SAN®

Hyperconverged 2-Node Scenario with Hyper-V 2016

Contacts

US Headquarters EMEA and APAC

1-617-449-77 17

1-617-507-58 45

1-866-790-26 46

+44 203 769 18 57 (UK)

+34 629 03 07 17

(Spain and Portugal)

Customer Support Portal:

Support Forum:

Sales:

General Information:

https://www.starwind.com/support

https://www.starwind.com/forums

[email protected]

[email protected]

StarWind Software, Inc. 35 Village Rd., Suite 100, Middleton, MA 01949 USA www.starwind.com

©2018, StarWind Software Inc. All rights reserved.