Sand Numberr 2010-6416C 1 Hydrogen Effects on Materials for CNG / H 2 Blends Brian Somerday*, David Farese** and Jay Keller* (Presenting) *Sandia National Laboratories, USA, **Air Products, USA Presented at the International Hydrogen Fuel and Pressure Vessel Forum 2010 Beijing, China September 28, 2010

Upload: others

Post on 13-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • Sand Numberr 2010-6416C 1

    Hydrogen Effects on Materials

    for CNG / H2 Blends

    Brian Somerday*, David Farese** and

    Jay Keller* (Presenting)

    *Sandia National Laboratories, USA, **Air Products, USA

    Presented at the

    International Hydrogen Fuel and Pressure Vessel

    Forum 2010

    Beijing, China

    September 28, 2010

  • Sand Numberr 2010-6416C 2

    Issue: Can existing CNG on-board storage tanks be used for HCNG?

    What are considerations for

    • Type 1, 2, 3, 4 tanks?

    • 20% H2 and less?

    • higher than 20% H2?

    Type 3 and Type 4 are likely fine

    • Comments from manufacturers

    Concern is primarily for steel Type 1 and Type 2 tanks

    • Commonly designed and manufactured according to

    NGV-2 and ISO 9809-1

  • Sand Numberr 2010-6416C 3

    a

    Number of pressure cycles, N

    crack in H2 or HCNG

    crack in CNG

    Dp a

    H2 H2 H2

    H2

    What is the concern for steel HCNG storage tanks?

    H2-assisted fatigue cracking

    Barthélémy, 1st ESSHS, 2006

    H2 cylinder

  • Sand Numberr 2010-6416C 4

    No concerns for HCNG in steel storage tanks if material strength is limited

    H2 compatibility of Cr-Mo steel cylinders designed to

    ISO 9809-1 demonstrated through service experience

    • Example: typical duty cycle for steel H2 trailer tubes in USA

    H2 pressure ~20 MPa

    pressure cycles ~2/week (50 year life)

    • Such service conditions bound the H2 partial pressure and

    number of pressure cycles for steel HCNG storage tanks

    • H2 transport cylinders must have tensile strength < 950 MPa

    All HCNG blends expected to be compatible with steel

    CNG tanks provided tensile strength < 950 MPa

    But CNG tanks designed to ISO 9809-1 allow tensile

    strength up to 1100 MPa

  • Sand Numberr 2010-6416C 5

    Issue: H2-assisted fatigue cracking enhanced in higher strength steel

    H2H2

    H2

    H2H2H2

    H2H

    HH

    load

    aH2

    H2H2

    H2H2H2

    H2H

    HH

    load

    a

    R. Irani, ISO/TC 58/WG 7 workshop, 2008

    950 MPa

    strength

  • Sand Numberr 2010-6416C 6

    ISO 11114-4 addresses H2 compatibility of steel cylinders with strength > 950 MPa in two ways

    According to ISO 11114-4, cylinders may be designed to ISO 9809-1 (i.e., with strength up to 1100 MPa) “if at least one of the following conditions for intended gas service is fulfilled:

    • the working pressure of the filled embrittling gas is less than 20% of the test pressure of the cylinder

    • the partial pressure of the filled embrittling gas of a gas mixture is less than 5 MPa (50 bar) in the case of hydrogen…”

    Based on ISO 11114-4, CNG tanks are suitable for

    HCNG blends with

  • Sand Numberr 2010-6416C 7

    Issue: steels are susceptible to H2-assisted fatigue cracking at low H2 pressures

    Recommend evaluating H2-assisted fatigue cracking in higher strength steels at low H2 pressure

    H2H2

    H2

    H2H2H2

    H2H

    HH

    load

    aH2

    H2H2

    H2H2H2

    H2H

    HH

    load

    a

    DK (MPam1/2

    )10 100

    da

    /dN

    (m

    m/c

    ycle

    )

    10-5

    10-4

    10-3

    10-2

    10-1

    7 MPa H2

    2.2 MPa H2

    0.14 MPa H2

    0.02 MPa H2

    air

    1020 Steelfrequency = 1 Hzload ratio = 0.15

    Fatigue cracking rates in

    H2 pressure < 5 MPa

    can be notably higher

    than rates in air

    Technical Reference on Hydrogen

    Compatibility of Materials, Sandia, 2008

  • Sand Numberr 2010-6416C 8

    ISO 11114-4 addresses H2 compatibility of steel cylinders with strength > 950 MPa in two ways

    ISO 11114-4 specifies that steels with strength >950 MPa can be qualified based on materials testing in H2 gas

    Evolving ISO 11114-4 currently specifies 3 tests:

    • Method A (disc rupture test)

    • Method B (crack propagation threshold test under step loading)

    • Method C (crack propagation threshold test under static load)

    Based on ISO 11114-4, CNG tanks suitable for HCNG

    blends with >20% H2 if steel passes qualification test

    However, qualification tests do not directly evaluate H2-

    assisted fatigue cracking

    Recommend evaluating H2-assisted fatigue cracking in

    higher strength steels at H2 partial pressure in blend

    2) Higher H2 partial pressures

  • Sand Numberr 2010-6416C 9

    Limited H2-assisted fatigue cracking data for higher strength steel cylinders are promising

    Higher strength cylinders with 400 MPa wall stress did not exhibit cracking in H2 after 17,000 cycles

    Dp

    H2 H2 H2

    H2

    strength < 950 MPa

    strength ~ 1100 MPa

    max. H2 pressure = 20 MPa

    Cr-Mo steel cylinders

    G. Bayer, Messer,

    1999

  • Sand Numberr 2010-6416C 10

    D K (MPa × m 1/2 ) 10 100

    da

    /dN

    (mm

    /cycle

    ) 10 -5

    10 -4

    10 -3

    10 -2

    0.088 MPa H 2

    0.081 MPa H 2 +0.007 MPa CO 2

    0.075 MPa H 2 +0.013 MPa nat. gas

    0.088 MPa nat. gas 0.101 MPa air

    1020 Steel frequency = 1 Hz load ratio = 0.05

    H2-assisted

    fatigue cracking

    rates in HCNG

    blend same as

    rates in pure H2

    Technical Reference on Hydrogen

    Compatibility of Materials, Sandia,

    2008

    Issue: Does CNG modify H2-assisted fatigue cracking of steels in gas blends?

    Some data show H2-assisted fatigue cracking

    same in HCNG and H2 …

    H2H2

    H2

    H2H2H2

    H2H

    HH

    load

    aH2

    H2H2

    H2H2H2

    H2H

    HH

    load

    a

  • Sand Numberr 2010-6416C 11

    Issue: Does CNG modify H2-assisted fatigue cracking of steels in gas blends?

    Why are fatigue cracking data for HCNG blends not consistent?

    … but other data show lower cracking

    rates in HCNG compared to H2

    H2H2

    H2

    H2H2H2

    H2H

    HH

    load

    aH2

    H2H2

    H2H2H2

    H2H

    HH

    load

    a

    I. Alliat, NATURALHY

    EC project, 2007

    0,01

    0,1

    1

    10

    100

    1 10 100

    Stress intensity factor range DK [MPa√m]

    Cra

    ck g

    row

    th r

    ate

    Da

    / DN

    [u

    m/c

    ycle

    ] reference curve EGKS, airBS 7910 airBase metal, natural gas, trapeziumBase metal, 50% ng+ 50% hydrogen, trapeziumBase metal, 50% ng+ 50% hydrogen, sinusBase metal, 100% hydrogen, trapeziumBase metal,100% hydrogen, sinus

    P = 66 bar

    m = 3

    X52 base metal

    Fatigue cracking

    rates in HCNG

    notably less than

    rates in pure H2

  • Sand Numberr 2010-6416C 12

    Constituents in CNG can inhibit H2-assisted fatigue cracking

    Can CNG constituent such as CO ensure resistance to H2-assisted fatigue cracking?

    H2H2

    H2

    H2H2H2

    H2H

    HH

    load

    aH2

    H2H2

    H2H2H2

    H2H

    HH

    load

    a

    J. Holbrook et al.,

    BNL report, 1986

    Gases such as O2 and CO are known

    to inhibit H2-assisted cracking

  • Sand Numberr 2010-6416C 13

    Summary

    No concerns for HCNG in steel storage tanks if

    material strength is < 950 MPa

    Recommend evaluating H2-assisted fatigue

    cracking in higher strength steels at H2 partial

    pressure in blend

    • Limited fatigue testing on higher strength steel

    cylinders in H2 shows promising results

    Impurities in CNG (e.g., CO) may provide

    extrinsic mechanism for mitigating H2-assisted

    fatigue cracking in steel tanks

  • 14