HARNETT COUNTY SFR 13 REHABILITATION WORK WRITE-UP GENERAL SPECIFICATIONS SHALL APPLY TO ALL WORK NCHFA & HPwES ENERGY STANDARDS APPLY TO ALL WORK SEE ATTACHED INFORMATION FOR ENERGY STANDARDS VERIFY ALL MEASUREMENTS REVIEW ATTACHED ASBESTOS SURVEY SCOPE OF WORK AFFECTED HIGHLIGHTED YELLOW PROPERTY ADDRESS: 1502 McLean Chapel Church Rd, Bunnlevel, NC 28323 OWNER'S NAME: Jamesena Brown PHONE #: 910.893.3694 CASE #: 5 LEAD: NO ASBESTOS: YES INSPECTION DATE: March 17, 2015 BID OPENING DATE: APPROXIMATE SIZE OF STRUCTURE: 1125 SQUARE FEET TOTAL ESTIMATED COST: $

Upload: others

Post on 12-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust

HARNETT COUNTY SFR 13

REHABILITATION WORK WRITE-UP

GENERAL SPECIFICATIONS SHALL APPLY TO ALL WORK

NCHFA & HPwES ENERGY STANDARDS APPLY TO ALL WORK

SEE ATTACHED INFORMATION FOR ENERGY STANDARDS

VERIFY ALL MEASUREMENTS

REVIEW ATTACHED ASBESTOS SURVEY SCOPE OF WORK AFFECTED HIGHLIGHTED YELLOW

PROPERTY ADDRESS: 1502 McLean Chapel Church Rd, Bunnlevel, NC 28323 OWNER'S NAME: Jamesena Brown PHONE #: 910.893.3694 CASE #: 5 LEAD: NO ASBESTOS: YES INSPECTION DATE: March 17, 2015 BID OPENING DATE: APPROXIMATE SIZE OF STRUCTURE: 1125 SQUARE FEET TOTAL ESTIMATED COST: $

Page 2: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust

Home Performance with ENERGY STAR Scope of Work

The Wooten Company Customer Name: Brown, Jamesena Customer Phone (h): 910.893.3694 Customer Address: 1633 McLean Chapel Rd Customer Phone (w): N/A City, State, Zip: Bunnlevel, NC 28323 Home Performance Analyst: Michael Boberg Inspection Date: March 17, 2015

Contractor,

Do not include this work in your cost estimate. All of the work below is listed in the Work Write Up.

All of the following work is to be in compliance with the NORTH CAROLINA HOUSING FINANCE

AGENCY SINGLE-FAMILY REHABILITATION LOAN POOL Rehabilitation Standards (effective June,

2013) D. Energy Efficiency Standards

1. Air Tightness:

a. All electrical and plumbing penetrations through floors, exterior walls and plates shall be sealed

with siliconized acrylic/latex caulk or polyurethane foam sealant. Remove existing attic

insulation to expose top of walls and all mechanical penetrations including electrical, plumbing,

HVAC and chases. Apply two-component polyurethane foam sealant to bridge, seal or fill wall

to ceiling connections, plumbing p-traps, mechanical penetrations in wall, ceiling and floors and

around ceiling Energy Star rated light fixture boxes. Provide foam backing board or batt

insulation for larger openings (chases, p-traps etc.) and then spray with the two-component

polyurethane foam to create an air barrier. Use Tiger Foam, Zero Draft or approved equal.

b. See Spec D1.1 & D1.2

2. Ventilation – Whole House

a. Install a whole-house mechanical fresh air ventilation system in compliance with ASHRAE 62.2-

2010. This ventilation system typically includes a fresh air make-up duct to the return side of the

air handler.

b. See Spec D2.1 & D2.3

3. Ventilation – Hall Bath and Kitchen

a. Install Energy Star bathroom ventilation system in hall bath.

b. Install 210 CFM, Energy Star labeled kitchen exhaust fan, vented to the outside.

c. See Spec D2.2 & D2.3 & D2.4.

4. Insulation – Floors

a. Install Kraft or foil-faced R-19 insulation between floor joists including mud-sill/band areas. An

insulation certification card shall be furnished by the contractor and posted at a conspicuous

location.

b. See Spec D3.1 & D3.2

5. Insulation – Attic

a. Install R-38 Insulation in attic.

Page 3: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust

b. See Spec D3.1 & D3.2

c. Replace disappearing attic stairway in hallway. Attic disappearing stairway shall be treated to

minimize radiant and infiltration heat loss. Spec. 14.B & Energy Standard D.3.12.

6. Windows and Exterior Doors

a. Install 10 (All windows not including storm doors) Energy Star Windows. Energy Star Labels to

remain on windows.

b. Replace all exterior doors with complete Energy Star R-7 insulated exterior door with peep hole,

double silicone weather-stripping energy efficient thresholds including jamb, frame and

hardware. Seal around door with non-expanding foam between framing and door jamb. Spec.

10.A. & Energy Standard D.3.13.

c. See Spec D3.4 & N.C. Energy Conservation Code for windows.

7. HVAC

a. Install electric heat pump.

b. Install duct system.

c. See Spec 19.D. and F. & Energy Standards D4.1, D4.2 & D4.3

8. Lighting

a. Install compact fluorescent lamps (CFLs), light emitting diodes (LEDs) or tubular fluorescent

bulbs in each light fixture.

b. See Spec D5.1

9. Appliances

a. Install new electric Energy Star hot water heater in the storage room.

b. See Spec. 17.B. & Energy Standard D5.2

c. Install new electric Energy Star clothes washer in laundry closet. Energy Standard D.5.2.

10. Crawl Space

a. Install 100% ground cover. Cover to be 6 mill thickness or greater.

b. See Spec D7.1

Page 4: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust

CONTRACTOR FIELD NOTES:

Page 5: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust
Page 6: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust
Page 7: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust

Case #: 5 Page Total $

REHABILITATION WORK WRITE-UP PROPERTY ADDRESS: 1502 McLean Chapel Church Rd, Bunnlevel, NC 28323 OWNER'S NAME: Jamesena Brown SIZE OF STRUCTURE: 1125 Square Feet CASE #: 5 LOCALITY: Harnett County SFR 13 INSPECTION DATE: 3.17.15 SITE WORK: Provide 8’ X 8’ X 16’ lockable, weather tight, storage container for duration of contract (60 days). $ CRAWL SPACE: Remove and properly dispose of all trash and refuse from the crawl space. Spec. 03.D. $ Provide treatment to protect against termites/insects/rodents. Spec. 03.A./B./C. $ Install crawl space access door with drywell. Spec. 04.G. and I. $ Install 6 mil poly ground cover. All accessible crawlspace area must have continuous 6 mil poly ground cover, wall to wall. Spec. 20.G. & Energy Standard D.7.1. $

Install 14 black, sliding foundation vents. Spec. 04.H. $ Install kraft or foil-faced R-19 insulation between floor joists including mudsill/band areas. An insulation certification card shall be furnished by the contractor and posted at a conspicuous location. Spec. 20.C. & Energy Standard D.3.9. $ EXTERIOR: Install vinyl siding with minimum R-3 rigid foam insulation sheathing on gable ends (approximatley 300 sq. ft.) and area at front of the house (approximately 300 sq.ft.) with siding. Install aluminum surrounds on window and door casings, fascia and continuous perforated soffits. Install 2 vinyl gable end vents. Spec. 06.D(1 and 2) & Energy Standard D.3.6. $ Install 2 full view storm door(s) at front and side entry. Door(s) to have a white finish (Larson brand or equal). Spec. 10.A.(4). & Energy Standard D.3.15. $ Seal around all windows and doors before and after installing aluminum surrounds and any visible holes or cracks leading from the building to the exterior Spec. 09.G. and 10.A.(7). & Energy Standard D.1.2.2. $ ROOF AND ATTIC: Provide a cost per square (10'x10') for roof sheathing. Do not include in bid. $ . Spec. 08.B. Remove existing roof. Install 25 year, 3 tab shingles including 15-pound felt, metal eave strip and continuous ridge vent with shingle on top. Cut roof sheathing at ridge for venting. Replace all plumbing boots and flashing. Spec. 08.C. & Energy Standard D.2.5. $ Replace approximately 160 feet of wood fascia board. Spec. 08.G. $

Page 8: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust

Case #: 5 Page Total $

Install approximately 100 feet of seemless guttering at front and back sides of home including downspouts, splash blocks / 6’ of piping to divert water away from foundation. Spec. 08.K. $ Replace disappearing attic stairway in hallway. Attic disappearing stairway shall be treated to minimize radiant and infiltration heat loss. Spec. 14.B. & Energy Standard D.3.12.(ASBESTOS) $ Disappearing attic stairs shall be framed such that R-38 insulation can be blown up to and around the opening. Install a R-10 styrofoam "lid" over folding stair frame in attic with R-30 batt insulation glued to the top of the “lid”. Top edge of frame shall be weatherstripped and “lid” will rest on weatherstripping. Energy Standard D.3.12. $ Remove all existing attic insulation to expose top of walls and all penetrations including electrical, plumbing, HVAC, drop soffits, chimney penetrations, top wall plate to drywall connections, bonus room, balloon framing and chases. Air seal to HPwES specifications as indicated in SYSTEMS before installing attic insulation. Install R-38 blown insulation in attic. An insulation certification card shall be furnished by the contractor and posted at a conspicuous location. Install baffles in rafter bays where rafters intersect with the top plate of exterior walls. (see detail for baffle installation) Spec. 20.A. & Energy Standard D.3.3. $ FRONT PORCH: 6’ WIDE X 4’ DEEP Install PVC handrailings around perimeter of porch and on both sides of steps. Spec. 07.E. $ Replace light fixture(s) with 1 compact fluorescent bulbs and interior wall switches. Spec. 18.D. and E. & Energy Standard D.5.1. $ SIDE ENTRY: 3’ WIDE X 3’ DEEP Install PVC handrailings on both sides of steps. Spec. 07.E. $ Install light fixture(s) with 1 compact fluorescent bulbs and interior wall switches. Spec. 18.D. and E. & Energy Standard D.5.1. $ SYSTEMS: Replace complete 40-gallon electric (minimum Energy Factor-0.93 with ENERGY STAR LABEL water heater in utility closet. Provide manufacturer’s documentation of the brand, model number and energy factor. Spec. 17.B. & Energy Standard D.5.2. $ Replace the house system water lines. Spec. 17.F.(2). $ Insulate all exposed water lines in unconditioned spaces with ½” pre-formed foam insulation. Spec. 17.F.(3). & Energy Standard D.3.10. $ Install exterior hose bibb at front and back of house. Spec. 17.F.(4) $ Install a washer hook-up in the laundry room. Spec. 17.H. $ Bring electrical up to the National Electrical Code. Install 200 amp electrical service and main panel box inside the house. All rooms to have a new light fixture and wall switch. Spec. 18.I. and Energy Standard D.5.1. $ Install electrically-operated smoke/carbon monoxide detector(s) to meet the National Electrical Code and State Building Code. Install GFIs to code. Check all switches and receptacles and leave in good working order. Install new cover plates throughout. Replace all light bulbs with compact fluorescent bulbs. Spec. 18.H. & Energy Standard D.6.4. $ Install a dryer hook-up and vent in the laundry closet. Spec. 18.J. $

Page 9: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust

Case #: 5 Page Total $

Install complete 15 SEER ENERGY STAR central heat pump HVAC system including heat, air conditioning, duct work, programmable interior thermostat, outdoor thermostat and electrical. The outdoor thermostat shall be set to the balance point of the house to prevent supplementary heater operation when the heat pump is capable of meeting the load. System shall be sized in accordance with ACCA Manual J specifications and must not exceed the Manual J calculated size by more than .5 ton. Calculations must be provided for HVAC and duct sizing. The delivery system ductwork shall be designed in accordance with ACCA Manual D standards and insulated. A copy of the ductwork design and sizing calculations with drawings shall be supplied to the Rehabilitation Specialist. All seams and joints to be sealed with bucket mastic. Install unit in a shaded location if possible. System must be pressure balanced. Contractor shall provide duct leakages compliance confirmation to Rehabilitation Specialist. Spec. 19.D. and F. & Energy Standard D.4.1./4.2/4.3 $ Install whole house mechanical fresh air ventilation system in compliance with ASHRAE 62.2-2010. Ventilation system will be a fresh air make-up duct to the return side of the air handler. Fresh air ventilation ducts shall originate at or beyond the external skin of the building and shall be filtered and dampered prior to reaching the coil. Filter shall be accessible by homeowner to change. Energy Standard D.2.1. $ Seal all penetrations through floors, walls and plates with siliconized acrylic/latex caulk or polyurethane foam sealant including electrical, plumbing, HVAC, drop soffits, chimney penetrations, top wall plate to drywall connections, bonus room, balloon framing and chases. Apply two-component polyurethane foam sealant to bridge, seal or fill wall to ceiling connections, plumbing p-traps, mechanical penetrations in wall, ceiling and floors and around ceiling light fixture boxes. Provide foam backing board or batt insulation for larger openings (chases, p-traps, etc.) and then spray with the two-component polyurethane foam to create an air barrier. Use Tiger Foam, Zero Draft or approved equal. See attached product information sheets. Energy Standard D.1.2.3. and Manufacturer’s Instructions. $ KITCHEN: 18’ WIDE X 12’ DEEP

Install 2 ENERGY STAR LABELED, vinyl, double-hung, double-glazed, replacement window units with built in J-channels, screens and interior trim. Seal around window frames with non-expanding foam between framing and window jamb/to reduce air infiltration. Window U-factor and SHGC of new windows must meet the current NC Energy Conservation Code. Spec. 09.A., & Energy Standard D.3.4. & NC Energy Conservation Code. $ Replace complete Energy Star R-7 insulated exterior door with peep hole, double silicone weatherstripping energy efficient thresholds including jamb, frame and hardware including dead bolt to meet code and door stop. Seal around door with non-expanding foam between framing and door jamb. Spec. 10.A. & Energy Standard D.3.13. $ Install luan underlayment, vinyl floor covering, and shoe molding. Requires total glue down. (approximately 216 sq. ft.). Spec. 13.A. and B. $ Paint walls. Spec. 16.D.(2). $ Install complete 8” deep, kitchen sink including 2.2 gpm faucet and all plumbing. Faucet to be a single-lever Delta faucet with sprayer or equal with 15 year drip free warranty. Spec. 17.A. & Energy Standard D.5.3. $ Replace existing light fixture with ceiling fan light combo with compact fluorescent bulbs and wall switch. Spec. 18.D. and E. and Energy Standard D.5.1. $ Install 210 CFM, ENERGY STAR LABLED Kitchen exhaust fan, Broan Under cabinet Range Hood, Model # QSE130 or equal, vented to the outside. Spec. 18.G. & Energy Standard D.2.4. $

Page 10: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust

Case #: 5 Page Total $

Replace refrigerator, electric range, clothes washer, electric clothes dryer to match existing type, brand and size. All appliances except electric range and electric clothes dryer must be ENERGY STAR LABLED or meet Energy Standard D.5.2. $ HALL BATHROOM: 5’ WIDE X 9’ Remove and replace complete 36” interior door to hallway including jamb, frame, hardware and doorstop. Spec. 10.B. $ Install tileboard walls and matching trim. Trim includes vinyl molding at edges and corners, crown molding, baseboards, and shoe molding. Spec. 12.E.(1). $ Install luan underlayment, vinyl floor covering and shoe molding. Requires total glue down. Spec. 13.A. and B. $ Install metal medicine cabinet with light and compact flourescent bulbs. Spec. 15.F. and Energy Standard D.5.1. $

Remove existing tub and tile surround and install complete fiberglass four (4) piece, ADA compliant, shower unit with seats including hand held 2.5 gpm shower head, curtain rod and all plumbing. Faucet to be a Delta or equal with 15 year drip free warranty. Spec. 17.C. & Energy Standard D.5.3. (Shower curtain to be provided by homeowner.) $ Install complete vanity with sink including 2.2 gpm faucet and all plumbing with 15 year drip free warranty. Faucet to be a Delta or equal. Spec. 17.D.(7). & Energy Standard D.5.3. $ Install complete ADA approved 19” highrise, elongated bowl, 1.3 GPF, water closet including seat and all plumbing. Water closet to be Kohler, or approved equal. Spec. 17.E. & Energy Standard D.5.3. $ Install 5-piece metal bath accessory group. Spec. 17.K. $ Install bathtub and shower/lavatory/water closet handicap grab bars. Each shall be handicap accessible. Spec. 17.K. $ Install minimum 80 CFM Energy Star exhaust fan, vented to the outside. Spec. 18.F. & Energy Standard D.2.2. $ Install R-15 insulation in new/exposed exterior walls. An insulation certification card shall be furnished by the contractor and posted at a conspicuous location. Spec. 20.C. & Energy Standard D.3.1. and D.3.6. $ Replace approximately 32 square feet of subfloor at toilet. Spec. 05.A. & .B. $ BEDROOM #1: 12’ WIDE X 11’ DEEP Install 2 ENERGY STAR LABLED, vinyl, double-hung, double-glazed, replacement window units with built in J-channels, screens and interior trim. Seal around window frames with non-expanding foam between framing and window jamb/to reduce air infiltration. Window U-factor and SHGC of new windows must meet the current NC Energy Conservation Code. Spec. 09.A., & Energy Standard D.3.4. & NC Energy Conservation Code. $ Repair 8’ x 8’ section of drywall at ceiling. Spec. 16.D.(3). (ASBESTOS) $ Repair 8’ x 8’ section of drywall at corner of bedroom walls. Spec. 16.D.(3).(ASBESTOS) $ Paint walls. Spec. 16.D.(2). $

Page 11: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust

Case #: 5 Page Total $

Spray ceiling with acoustical spray. Spec. 16.D.(3). $ Install ceiling fan/ light combo with compact fluorescent bulbs and wall switch. Spec. 18.D. and E. and Energy Standard D.5.1. $ BEDROOM #2: 12’ WIDE X 11’ DEEP Install 2 ENERGY STAR LABELED, vinyl, double-hung, double-glazed, replacement window units with built in J-channels, screens and interior trim. Seal around window frames with non-expanding foam between framing and window jamb/to reduce air infiltration. Window U-factor and SHGC of new windows must meet the current NC Energy Conservation Code. Spec. 09.A., & Energy Standard D.3.4. & NC Energy Conservation Code. $ BEDROOM #3: 12’ WIDE X 11’ DEEP Install 1 ENERGY STAR LABELED, vinyl, double-hung, double-glazed, replacement window units with built in J-channels, screens and interior trim. Seal around window frames with non-expanding foam between framing and window jamb/to reduce air infiltration. Window U-factor and SHGC of new windows must meet the current NC Energy Conservation Code. Spec. 09.A., & Energy Standard D.3.4. & NC Energy Conservation Code. $ LIVING ROOM: 16’ WIDE X 11’ DEEP Install 4 ENERGY STAR LABELED, vinyl, double-hung, double-glazed, replacement window units with built in J-channels, screens and interior trim. Seal around window frames with non-expanding foam between framing and window jamb/to reduce air infiltration. Window U-factor and SHGC of new windows must meet the current NC Energy Conservation Code. Spec. 09.A., & Energy Standard D.3.4. & NC Energy Conservation Code. $ Install ceiling fan/light fixture with compact fluorescent bulbs and wall switch. Spec. 18.D. and E. and Energy Standard D.5.1. $ Replace complete Energy Star R-7 insulated exterior door with peep hole, double silicone weatherstripping energy efficient thresholds including jamb, frame and hardware including dead bolt to meet code and door stop. Seal around door with non-expanding foam between framing and door jamb. Spec. 10.A. & Energy Standard D.3.13. $ UTILITY ROOM: 5’ WIDE x 6’ DEEP Replace complete Energy Star R-7 insulated exterior door with peep hole, double silicone weatherstripping energy efficient thresholds including jamb, frame and hardware including dead bolt to meet code and door stop. Seal around door with non-expanding foam between framing and door jamb. Spec. 10.A. & Energy Standard D.3.13.. $

Page 12: HARNETT COUNTY SFR 133. Ventilation – Hall Bath and Kitchen a. Install Energy Star bathroom ventilation system in hall bath. b. Install 210 CFM, Energy Star labeled kitchen exhaust

WORK WRITE-UP BID SHEET PROPERTY ADDRESS: 1502 McLean Chapel Church Rd., Bunnlevel, NC 28323 OWNER'S NAME: Jamesena Brown CASE #: 5 BID DATE:

I, the undersigned contractor, have inspected the foregoing listed property and understand the extent and character of the work to be completed as described in the Work Write-Up. I propose to furnish all labor, material and equipment necessary to accomplish the work as indicated above, for the sum of: _____________________________________________________________________ Dollars, ($________________________________________)

Contractor SSN or Fed ID and General Contractor’s License Number (if licensed) Address City State Zip Code Phone Number Signature Date

W-9

Contractor’s Registration Form

Evidence of Insurance

Certified Renovator’s Certificate

If these documents are not submitted with your bid, your bid will be disqualifed.

OFFICE USE ONLY

General Contractor’s License

confirmed date:_____________ / ini_____

Not Debarred

confirmed date:_____________ / ini_____

Certified Renovation Firm

confirmed date:_____________ / ini_____

Certified Renovator

confirmed date:_____________ / ini_____

Certified Lead Supervisor

confirmed date:_____________ / ini_____

Insurance

confirmed date:_____________ / ini_____

Bid is responsive/ responsible

Bid is NOT responsive/ responsible

IF not responsive, state reason:

______________________________________________

______________________________________________