kitchen ventilation 101

55
VENTILATION 101 PRESENTATION BY Nick Kress CRA, UDCP Builder Account Manager

Upload: katya-vilchyk

Post on 20-May-2015

1.570 views

Category:

Business


7 download

DESCRIPTION

An educational presentation on Kitchen Ventilation Basics prepared by Nick Kress, CRA, UDCP of Standards of Excellence Appliances & Decorative Plumbing. Nick is NARI Certified Remodeler Associate as well as NARI Universal Design Certified Professional. standardsofexcellence.com/nkress

TRANSCRIPT

Page 1: Kitchen Ventilation 101

VENTILATION101

PRESENTATION BY

Nick Kress CRA, UDCPBuilder Account Manager

Page 2: Kitchen Ventilation 101

More often than not, homeowners have either NEVER USED the hoods that exist in their kitchens or in the case of older homes, NEVER HAD A SYSTEM of removing moisture and heat produced when cooking in the kitchen.

Page 3: Kitchen Ventilation 101

Today hood manufacturers not only offer a multitude of SIZES, STYLES and SHAPES, but also they are able to provide the POWER required for efficiently removing heat and moisture. This can be achieved with NOISE LEVELS that begin as low as 0.08 sone.

Page 4: Kitchen Ventilation 101

The KEY TO PROPER HOOD SELECTION depends on many variables which should be evaluated and discussed with homeowners before they embark on the appliance selection process.

Always follow manufacturer recommendations and local codes.

Page 5: Kitchen Ventilation 101

Determine cubic feet of kitchen area for initial cubic feet of air movement recommended

Calculate additional cfm recommended based on the size and fuel type of cooking appliance

Design and measure the duct run and determine your EDL (Equivalent Duct Length)

Consider air capture of hood based on design and location of the hood.

Page 6: Kitchen Ventilation 101

Consider additional variables in the kitchen design

Provide make up air when required

Page 7: Kitchen Ventilation 101

Determine

CFMfor kitchen area

Page 8: Kitchen Ventilation 101

Let’s assume this kitchen is 9 FEET WIDE (X)10 FEET LONG (Y)with a ceiling height of 8 FEET TALL (Z)

1. Determine the cubic feet (CF) within the kitchenX x Y x Z = CF9 x 10 x 8 = 720

2. Multiply the CF by the recommended air changes per hour (ACH) for a kitchen (which is 15)720 x 15 = 10,800

3. Divide that number by 60 minutes10,800 ÷ 60 = 180 CFM

EXAMPLE

Page 9: Kitchen Ventilation 101

Determine CFMrequired for cooking surface

FUEL TYPESIZE

FEATURES

Page 10: Kitchen Ventilation 101

Add 100 cfm for every 10,000 BTU (British Thermal Unit) of heat produced on cooking surface.

EXAMPLE 6 burners x 15000 BTU each = 90000 BTU90k / 10k = 900 cfm

NOTE If the cook top has a grill or griddle, add 500 cfm for every 12” of each

6 burners x 15000 BTU each = 90000 BTU90k / 10k = 900 cfm

GAS COOKING

Page 11: Kitchen Ventilation 101

Add 100 cfm for every 10” of cooking surface.

EXAMPLE On a 36” induction cook top36/10 x 100cfm = 360 cfm

On a 36” induction cook top36/10 x 100cfm = 360 cfm

ELECTRIC / INDUCTION COOKING

Page 12: Kitchen Ventilation 101

Calculate

EDLEquivalent Duct Length

Page 13: Kitchen Ventilation 101

DEDUCT 1 cfm for every foot of duct run PLUS 20 cfm for every elbow PLUS 30 cfm for the wall cap

EXAMPLE A duct run is 20’ with two 90 degree elbows (radius turns) and one 45 degree elbow ending at the wall cap. Calculation:20 cfm + 60 cfm + 30 cfm = 110 cfm (EDL or Equivalent Duct Length). This should be added to the previously determined amounts for the total requirement for the hood.

20 cfm + 60 cfm + 30 cfm = 110 cfm

CALCULATE THE DUCT RUN REQUIREMENT

Page 14: Kitchen Ventilation 101

RECAP

Page 15: Kitchen Ventilation 101

Kitchen area9 feet wide (X)10 feet long (Y) 8 feet ceiling height (Z)

Cooking surface36” gas cook top four 16K BTU burners &a 12” grill

A duct run 15’ with one 90 degree elbow (radius turns) and two 45 degree elbows ending at the wall cap.

LET’S DETERMINE THE CFM REQUIRED FOR THE FOLLOWING EXAMPLE

Page 16: Kitchen Ventilation 101

Room cfm requirement:9 x 10 x 8 = 720 cubic feet720 x 15 = 10800 ACH / 60 min =

Range top cfm requirement:16K x 4 = 64K BTU64K BTU / 10K = 640 cfm + 500 cfm (grill) =

Ducting cfm requirement:15 x 1 = 15 + 60 + 30 =

TOTAL RECOMMENDED CFM =

CALCULATIONS

180 cfm

640 cfm1140 cfm

1425 cfm

105 cfm

Page 17: Kitchen Ventilation 101

Variablesto Consider

when Making theFinal Selection

Page 18: Kitchen Ventilation 101

Location of cooking surface – wall or island. Consider increasing coverage for an island hood.

Cooking appliance manufacturer recommendations for ventilation.

Hood manufactures required distance from cooking surface.

Ceiling height and mounting options.

Page 19: Kitchen Ventilation 101

Width and depth of cooking surface

Design of hood chosen and depth of hood sump.

Type of blower –internal, in line or external remote blower.

Noise level of selected hood on lowest speed and highest speed.

Page 20: Kitchen Ventilation 101

Hood lighting and “Green Features”

Only use downdraft ventilation when recommended by the manufacturer. Only 2 manufacturers of pro style ranges and range tops approve their own downdraft products for select models.

Page 21: Kitchen Ventilation 101

Make Up Air

Page 22: Kitchen Ventilation 101

2012 IRC CODES REGARDING MAKE UP AIR

Makeup air requirements associated with vented kitchen range hoods:(IRC M1503.4, M1501.2, G2447.6)

Three code provisions can trigger the need for makeup air in this situation. The bottom line is that makeup air is always required for high-volume hoods (> 400 cfm) and may be required for lower volume hoods when natural-draft appliances are used.

M1503.4 requires makeup air for kitchen hoods which exhaust more than 400 cfm. The makeup airflow rate must equal the exhaust flow rate and an intake damper on the makeup air duct must be interlocked with the control for the fan.

M1501.2 requires that “ducted exhaust systems” (such as kitchen hoods, bath fans, clothes dryers) not induce negative pressure in excess of negative 3 Pascals at the location of a natural draft combustion appliance. This provision applies regardless of the rated airflow of the exhaust system.

G2447.6 reinforces M1501.2, more explicitly for vented kitchen hoods. This provision is independent of the rated airflow through the hood.

A pressure test is required to demonstrate that the depressurization level is within the 3 Pascal limit. If the depressurization limit is exceeded, makeup air is one potential solution.

There is no requirement to temper makeup air.

Page 23: Kitchen Ventilation 101

REASONS TO HAVE MAKE UP AIR

•Recommended by hood manufacturer•HEALTH - Carbon Monoxide, contaminants•SAFETY - fireplace ambers•Avoiding negative air pressure•Local building codes

Page 24: Kitchen Ventilation 101

Verify the dampers operate properly.

Do not oversize the exhaust fan

Page 25: Kitchen Ventilation 101

Make Up AirSystems

Page 26: Kitchen Ventilation 101
Page 27: Kitchen Ventilation 101

VentilationSystem Noise

What can increase the noise level of the hood?

Page 28: Kitchen Ventilation 101

BLOWER MOTOR: TYPESingle phase - Three phase - Linear

LOCATION

FILTER: TYPEMesh - Baffle - Channel - Recirculating - Downdraft

DESIGN: HOOD DUCT

length, turns, interior obstacles

NOISE SUPPRESSION SYSTEMSIn line silencers

Page 29: Kitchen Ventilation 101
Page 30: Kitchen Ventilation 101

EXAMPLES

Well Matched Hoods& Cooking Surfaces

Page 31: Kitchen Ventilation 101
Page 32: Kitchen Ventilation 101
Page 33: Kitchen Ventilation 101
Page 34: Kitchen Ventilation 101
Page 35: Kitchen Ventilation 101
Page 36: Kitchen Ventilation 101
Page 37: Kitchen Ventilation 101

EXAMPLES

Approved Kitchen Ventilationalthough not always recommended

Page 38: Kitchen Ventilation 101
Page 39: Kitchen Ventilation 101
Page 40: Kitchen Ventilation 101
Page 41: Kitchen Ventilation 101
Page 42: Kitchen Ventilation 101
Page 43: Kitchen Ventilation 101
Page 44: Kitchen Ventilation 101

EXAMPLES

Unique Kitchen Ventilation Designs

Page 45: Kitchen Ventilation 101
Page 46: Kitchen Ventilation 101
Page 47: Kitchen Ventilation 101
Page 48: Kitchen Ventilation 101
Page 49: Kitchen Ventilation 101
Page 50: Kitchen Ventilation 101
Page 51: Kitchen Ventilation 101
Page 52: Kitchen Ventilation 101

The Bloopers

Kitchen Ventilation Selections

Page 53: Kitchen Ventilation 101
Page 54: Kitchen Ventilation 101
Page 55: Kitchen Ventilation 101