ge power pres 1

24
1 GE Power Automation System

Upload: r-bambang-widiatmoko

Post on 08-Nov-2014

185 views

Category:

Documents


28 download

TRANSCRIPT

1

GE Power Automation System

2

What is GE Power ?

• Power automation solution

• Substation level SCADA

• Human-Machine Interface

• Communication gateway

• Open system based on international standards

• Tool for implementation of customized schemes

• Embedded IEC 61850 implementation

GE Power Automation System is a dedicated system for automation and control of utility and industrial substations.

3

What is GE Power ?• Cost effective and complete power automation system

• Distributed and scalable system architecture

• Connects multiple devices to the substation via various physical media and communications protocols

• Connects the whole substation to the Control Centre using typical telecontrol protocols.

• Application that consists of different software packages • GE CONF: System configuration, data mapping, HMI configuration• GE POWER View: Graphical HMI for process visualization• PLC Logic Editor: Automation functions• GE Files: Trending and analysis of historical data

• Ready to run on embedded hardend platform – CCU 1000 hardware

4

What is CCU 1000 ?

• CCU 1000 is embedded industrial platform designed to run GE Power Automation software.

• CCU 1000 is a station computer with full automation functionality.

• Provides connectivity to protection and control devices within the plant or substation, includes monitoring and control and connection to Network Control Centers.

• CCU 1000 is truly harsh environment ready hardware ideal for severe conditions in electrical substation or in industrial plants.

• Outstanding reliability thanks to:• No mechanical moving parts• No rotating hard drives, fans, CD/DVD drives• No CMOS battery• Redundant AC/DC power supply• Tested in harsh environments• Write protected OS and applications • Static data logging through Flash disk

5

GE Power Applications

• Local substation monitoring and control

• Remote substation control

• Motor Control Centers SCADA

• Multi-protocol communications

• Local and remote HMI via communications

• Automation functions at substation level:

• interlocking schemes

• auto-sequencing, etc.

• Data recorder

• History of measures

• Trending

• Events

• Alarm processing

• Generation of reports

6

LEVEL 2 – Substation Integrated Protection & Control & Metering• Communication Network: Point to Point Fiber, Ethernet

• Multiplexers, Hubs, Switches.

• Communication Processor: PC, RTU, PLC

• HMI: Graphic Screen, Touch Screen

Communications in Power Systems

LEVEL 0 - Primary Equipment

Breakers, Disconnectors, Switches, Power Transformers, VTs, CTs, Shunt Reactors

LEVEL 1 – Secondary Equipment

IEDS: Relays, Meters, RTUs

LEVEL 3 – Interface To Dispatch Center• Telephone Modem, Radio Modem, GSM Modem, Multiplexer, Power Line Carrier

• SCADA Protocol: IEC 60870-5-101/104, DNP 3.0, WISP, INDACTIC 2033

7

Typical Architecture based on GE Power

RS485 Daisy Chain

NCC SCADA

Fiber Optic Multiplexer

Fiber to RS485Converter

Level 3Control Center

Level 2Substation

Level 1IEDs

Level 0Primary Equipment

IEC 61850 - Ethernet TCP/IPStation Bus

Local HMIOperator Workstation HMIwith GE Power

Legacy IEDs

CCU 1000Station

Computerwith GE Power

IEC 60870-5-101, IEC 60870-5-104, DNP3.0, Modbus

8

Configuration and Data Mapping Application

Configure the substation with the required relays.

Information is loaded from models.

Define the point for Level3 integration.

Design the screens both with bitmaps and live objects

9

• Possibility to show status of all motors at a glance

• IEDs are represented with different colors depending on their status.

• Incomers and with measured values

• Clicking with the mouse on any motor or feeder results in going to another screen showing all the details about that motor or feeder.

Single Line Diagram with GE Power

10

• View of the system incomers and bus-couplers in their actual locations

• Detailed information of any of the represented elements is available with just one mouse click

Elevation Panels with GE Power

11

PLC Logic Editor with GE Power

Define simple control sequences in design mode

Debug the control sequences in Run-time

12

• On-line retrieval of complete information about any system component

• Possibility to search for any IED within the system by entering its code. View measured values, maintenance, commands, memory map, settings, cause of the last trip, etc.

Motor Selection Commands

Maintenance

Memory MapOnline

TrendingMotor Manager Keypad Access

Actual Values

                                  

View of IEDs with GE Power

13

• Possibility to view all the system alarms.

• The program offers the option to acknowledge the alarms, and filter them according to the priority level.

View of Alarms with GE Power

14

Possibility to view communication status of all the system IEDs identified with colours.

Status of Communications with GE Power

15

GE Power Reference List and Projects

16

CUSTOMER LOCATION SUBSTATION VOLTAGEAES Brazil PATUCARA 69/13.8 kVCEEE Brazil CAXIAS 5 69/13.8 kV

138/69 kV138/13.8 kV

CEEE Brazil MAGAMBARA 138/34.5/13.8 kVCEEE Brazil PORTO ALEGRE 12 69/23 kVCEEE Brazil PORTO ALEGRE 13 230/13.8 kVCEEE Brazil SANTA CRUZ 230/69/13.8 kVCEEE Brazil SANTA ROSA 138/34.5/13.8 kVCEEE Brazil SAO BORJA II 138/34.5/13.8 kVCEEE Brazil VIAMAO 69/23 kV

CEEE/ GENERAL MOTORS Brazil DISTRITO INDUSTRIAL 45/20 kVCFE Mexico DURANGO 45 kVCFE Mexico TULUM 132/13.8 kVCFE Mexico PICHUCALCO 132/13.8 kV

CHESF Brazil ANGELIM 400 kVCOPEL Brazil ALTO DA GLORIA 138/13.8 kVCOPEL Brazil BATEIAS 138/69 kVCOPEL Brazil HORIZONTE 138/13.8 kVCOPEL Brazil OLIMPICOS 138/13.8 kV

EDAR DE BESOS Spain EDAR DE BESOS 45 kVEDESA Argentina 25-may 45/15 kVEDESA Argentina SAN FRANCISCO 45/15 kVEDESA Argentina ZORRILLA 15 kV

ELECTRONORTE Brazil ALTAMIRA 69/23 KvELECTRONORTE Brazil RUROPOLIS 69/23 kVELECTRONORTE Brazil TRANSAMAZONICA 69/23 kVELECTRONORTE Brazil TUCURUI 69/23 kV

ENDESA Spain AGREDA 45/10 kVENDESA Spain ALCALA 45/10 kVENDESA Spain ALCAÑIZ 132 kVENDESA Spain ALMUDEVAR 45 kVENDESA Spain BELCHITE 45/20 kVENDESA Spain CALANDA 45/10 kVENDESA Spain CASTING ROS 132/45 kVENDESA Spain CELLA 132/45/20 kVENDESA Spain ESCUCHA 220/132 kVENDESA Spain LA ALMUNIA 45/10 kVENDESA Spain LA MUELA 45/10 kVENDESA Spain LA PEÑA 45/10 kV

CEEE Brazil ERECHIM

GE Power Reference List (1)

17

CUSTOMER LOCATION SUBSTATION VOLTAGEENDESA Spain LA PUEBLA 45/20 kVENDESA Spain LOS VIENTOS 132 kVENDESA Spain MAGALLON 220/132 kVENDESA Spain MOLINO MAYOR 45/10 kVENDESA Spain MONCAYO 220/132 kVENDESA Spain ONCALA 220/30 kVENDESA Spain PINA DE EBRO 45/10 kVENDESA Spain POLA 45/10 kVENDESA Spain SET ANSO 45/10 kVENDESA Spain UTRILLAS 45/15 kV

MEB United Kingdom BURSLEM 132/11 kVMERCEDES BENZ Spain VITORIA 132/45/15 kV

PEA Thailand DAMNOENSADUAK 115/22 kVPEA Thailand PAKTHO 115/22 kVPEA Thailand PHOTHARAM 115/22 kVPEA Thailand RATCHABURI 2 115 kVPEA Thailand SAI NOI 115 kVPEA Thailand U-THONG 115/22 kVPEA Thailand PEA 3.2 A 115/22 kVPEA Thailand PEA 3.2 B 115/22 kV

PROFERTIL Thailand INDUSTRIAL 380 kVRIO GRANDE ENERGIA Brazil CACHOEIRINHA 69/23 kVRIO GRANDE ENERGIA Brazil GAURAMA 69/23 kVRIO GRANDE ENERGIA Brazil GETULIO VARGAS 69/13.8 kVRIO GRANDE ENERGIA Brazil LAGOA VERMELHA 138/23 kVRIO GRANDE ENERGIA Brazil MARAU 138/23 kVRIO GRANDE ENERGIA Brazil PAIM FILLHO 69/23 kVRIO GRANDE ENERGIA Brazil PAROBÉ 138/13.8 kVRIO GRANDE ENERGIA Brazil PASSO FUNDO 138/13.8 kVRIO GRANDE ENERGIA Brazil SAN FRANCISCO DE PAULA 69/23 kVRIO GRANDE ENERGIA Brazil VERANAPOLIS 138/69/13.8 kVRIO GRANDE ENERGIA Brazil CASCA 69/23 kVRIO GRANDE ENERGIA Brazil FLORES DA CUNHA 69/23 kVRIO GRANDE ENERGIA Brazil PASSO FUNDO 69/23 kV

RIO LIGHT Brazil FREI CANECA 33 kVSIDMED Spain SIDMED 220 kVENDESA Spain María 220 kVENDESA Spain Los Vientos 45/10 kVENDESA Spain Pol. Ind. Andorra 45/10 kVENDESA Spain Sist. Int. La Muela 45/10 kV

GE Power Reference List (2)

18

CUSTOMER LOCATION SUBSTATION VOLTAGEENDESA Spain Sist. Integr. Repuesto 45/10 kVENDESA Spain Magallon 45/10 kVENDESA Spain Montoro 45/10 kVENDESA Spain Alcañiz 45/10 kVENDESA Spain Monegros 45/10 kVUNELCO Spain Cinsa 66/22 kVUNELCO Spain Chayofa 66/22 kVUNELCO Spain Salinas 66/22 kV

ZHEIJIANG ELECTRIC POWER Co.

China When Zhou 500 kV

ZHEIJIANG ELECTRIC POWER Co.

China Ning Bo 500 kV

ZHEIJIANG ELECTRIC POWER Co.

China Hang Dong 1 500 kV

ZHEIJIANG ELECTRIC POWER Co.

China Lang Ting 500 kV

ZHEIJIANG ELECTRIC POWER Co.

China Wang Dian 500 kV

ZHEIJIANG ELECTRIC POWER Co.

China Hang Dong 2 500 kV

MEB UK Boothen 132/33/11 kVADMA OPCO-ABU DHABI United Arab Emirates Umm Shaif Control Center

DANWAY United Arab Emirates Takreer – Umm Al Nar Ref inery S/S 11 A/B & 11C/D

415 V Motor Control Center

DANWAY United Arab Emirates Takreer – Umm Al Nar Ref inery S/S 51 & 29A

415 V Motor Control Center

ETESA PANAMA Colon PanETESA PANAMA Colon Pan

MEB UK Burslem 132/33/11 kVENDESA SPAIN Berdun 132/45/15 kVENDESA SPAIN JacaSur 132/45/15 kVENDESA SPAIN Alcala 132/45/15 kVENDESA SPAIN Villel 132/45/15 kVENDESA SPAIN Pifuentes 132/45/15 kVENDESA SPAIN Mediavega 132/45/15 kVENDESA SPAIN Fuenfresca 132/45/15 kVENDESA SPAIN Calanda 132/45/15 kVENDESA SPAIN Agudas 132/45/15 KvUNELCO SPAIN AMP. CINSA 66/22 KvUNELCO SPAIN S. AGUSTIN 66/22 KvENDESA SPAIN HUESCA ESTE 45/15 KvENDESA SPAIN MORATA 45/15 KvUNELCO SPAIN MATASBLANCAS 66/22 KvENDESA SPAIN CALANDA 45/15 Kv

LINDE AG SAUDI ARABIA GAS V – National Industrial Gases Co. 34.5 kV & 13.8 kV System URUGUAY TRINIDAD 15/6Kv

EKOSINERJI TURKEY KARDEMIR Control System

GE Power Reference List (3)

19

CUSTOMER LOCATION SUBSTATION VOLTAGESIDMED SPAIN SIDMED 45/15Kv

SOLUZIONA SPAIN NAVAS DEL MARQUES 45/6KvGE PLASTICS SPAIN SE60100/60200 6KvIBERDROLA SPAIN RETUERTO 132Kv

ATRAK IRAN KERMANSHAH 400KvATRAK SYRIA JALAA 60/20 Kv

ONE MOROCCO CHICHAOUA 225/150/60KvONE MOROCCO AZZOUZ 225/150/60KvONE MOROCCO KHOURIBGA 225/150/60KvONE MOROCCO D’EL JADIDA 225/150/60KvONE MOROCCO LAATAM 225/150/60KvONE MOROCCO BENI MATHAR 225/150/60KvONE MOROCCO GHERCIF 225/150/60KvONE MOROCCO ZENATA 225/150/60KvONE MOROCCO AMLIL 225/150/60Kv

GE Power Reference List (4)

20

Project I - Simeri Crichi, World Largest IEC 61850 Installation

WorkStation 2DOT MATRIX EVENT PRINTER

CCU1000 Substation Computers

IEC 61850 on Fiber Optic Ethernet

Redundant Connections

Antenna

GPS Receiver

IRIG-B

UR

DCS IEC-104 or/and OPC DA & AE

F650

GE UR x 23 + GE F650 x 215 + AVR x 2 + Third-Party IED x 4 : IEC61850

Third party Modbus RTU

IEDs

WorkStation 1

GE POWER HMI

CCU 1000

Third-party IEDs

AVR

UR UR

F650 F650IRIG-B

21

Project II - ULG/LSGO Project, TAKREER

Fiber or RS-232 to RS-485 Converters

Fiber

Substation Ethernet TCP/IP Copper( Optional Glass Fiber )

Modbus Protocol

DCS

Copper

2xSR745 + 7xSR750 + 8xSR469

3 x SR750 + 5xMIF + 9xMMII

18 x MMII

18 x MMII

18 x MMII

18 x MMII

18 x MMII

EWS

Redundant Station Controllers

22

Project III - Centrale di Altomonte

DAC300 Fiber to RS-485 Converter

Glass FiberMODBUS RTU

Copper Ethernet

EWS-1 CCU 1000

5 x MODBUSRS-485 Daisy Chains connecting 50 x MMIILV Motor Managers

MV => 67 x F650

Fiber Optic Ethernet Ring.IEDs connected to the LAN through Dual Fiber Optic connections. Modbus TCP/IP.TG1, TG2 & TV => 14 x F650 +

12 x UR

GPS ClockEWS-2

IRIG-B Link

Hot - Standby Link

To DCS

Connection to is DCS IEC 870-5-104. Fiber 100 Mbps ST ConnectorAvailable also: IEC-870-5-101 and MODBUS RTU over RS-232 from CCU1000

Application Details :

• The CCU 1000 retrieves data from MMII via MODBUS RTU, from F650 and UR via MODBUS TCP/IP.• The DCS retrieves data from CCU 1000 via IEC-870-5-104. Available also IEC-870-5-101 and MODBUS through direct connection to CCU 1000 RS-232 ports.• The engineering workstations retrieve data from CCU 1000 using an OPC connection.• In case of IEC-870-5-104 protocol, the DCS can access directly the UR and F650 relays, using the same network. • The GPS clock includes an IRIG-B output to synchronize the relays. Amplifiers are not included

CCU 1000

DCS SCAD

A

23

Project IV - AL JUBAIL GAS V PROJECT

34.5kV & 13.8 kV

• 8 x T60• 6 x F60• 4 x M60

• 6 x 469• 6 x 750

• 3 x 750

• 13 x MMII

• 13 x MMII

• 14 x MMII

4.16 kV

480 V

• 5 x C30

AA/SOER

• 32 Analog Inputs• 336 Digital Inputs• 40 Digital Outputs

I/Os

Fiber to RS-485Converter

Glass FiberMODBUS RTU

ETHERNET TCP/IP. Glass Fiber

ETHERNET TCP/IP. Copper

EWS

Sequence of Event Recorder ( SOER), Event Printer, Alarm Annunciator Panel

RS-485 Daisy Chains

Remote Access

CONTROL ROOM

Redundant Station ControllersRemote Access

Laptop Access ( Optional )

Inkjet Printer

Laser Printer

24

Thank You for Your Attention !