foam systems · pdf filek.c. antincendi s.r.l. via pavia 76 27042 bressana bottarone (pv)...

1
© K.C. Antincendi S.r.l. | Via Pavia 76 | 27042 Bressana Bottarone (PV) | Italy | [email protected] 30 C.02 C.01 S J C N O K L A.06 A.08 A.01 A.03 A.04,02 A.05 M I A A.07 30 C.02 C.01 S J C N O D.1 D V W D.1 W P Q B PRODUCT SHEET Note: This document contains basic product information only. Information, photos and drawings are not contractually binding. In all cases, the manufacturer’s full technical documentation remains the reference document. The contents of this publication are subject to modifications without notice. All rights reserved. Pos. Description Pos. Description A Foam concentrate bladder tank, including: D Hydraulic actuated valve (optional) A.01 Water drain/Fill valve D.1 Hydraulic actuated valve supply shut-off valve A.02 Foam concentrate level drain I System check valve A.03 Concentrate drain / fill valve J Alarm line piping A.04 Foam level hydrometer valve K Bladder tank water supply control valve A.05 Hydrometer (Foam concentrate gauge) L Foam concentrate control shut-off valve A.06 Tank water vent valve M Foam concentrate swing check valve A.07 Diaphragm concentrate vent valve N Foam solution test valve (optional) A.08 Hydrostatic relief valve O System isolation valve (optional) B Wide range proportioner P Water supply piping to bladder tank C Alarm check valve model J-1 and trim Q Foam concentrate discharge piping C.01 Water supply control valve S Retard chamber C.02 Water motor alarm V Auxiliary valve (Hydraulic valve release) (optional) SP2.3.10.8/0417/en These drawings are provided for guidance only and are not guaranteed to be up to date, accurate for every installation or to be compliant with local regulations. Foam Systems Multiple Foam Wet System - Pre-Piped (European) TO SYSTEM FROM WATER SUPPLY FOAM/WATER TO SYSTEM FOAM/WATER SOLUTION FOAM/WATER

Upload: dangliem

Post on 05-Feb-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Foam Systems · PDF fileK.C. Antincendi S.r.l. Via Pavia 76 27042 Bressana Bottarone (PV) Italy info@kcantincendi.com 36 30 C.02 C.01 S J C N O K L A.06 A.08 A.01 A.03 A.04,02 A.05

© K.C. Antincendi S.r.l. | Via Pavia 76 | 27042 Bressana Bottarone (PV) | Italy | [email protected]

3 6

30

C.02

C.01

S

J

C

N

O

K

L

A.06

A.08

A.01A.03

A.04,02A.05

M

I

A

A.07

30

C.02

C.01

S

J

C

N

O

D.1

D

V

WD.1W

P

Q

B

PRODUCT SHEET

Note: This document contains basic product information only. Information, photos and drawings are not contractually binding. In all cases, the manufacturer’s full technical documentation remains the reference document.The contents of this publication are subject to modifications without notice. All rights reserved.

Pos. Description Pos. DescriptionA Foam concentrate bladder tank, including: D Hydraulic actuated valve (optional)A.01 Water drain/Fill valve D.1 Hydraulic actuated valve supply shut-off valveA.02 Foam concentrate level drain I System check valveA.03 Concentrate drain / fill valve J Alarm line pipingA.04 Foam level hydrometer valve K Bladder tank water supply control valveA.05 Hydrometer (Foam concentrate gauge) L Foam concentrate control shut-off valveA.06 Tank water vent valve M Foam concentrate swing check valveA.07 Diaphragm concentrate vent valve N Foam solution test valve (optional)A.08 Hydrostatic relief valve O System isolation valve (optional)B Wide range proportioner P Water supply piping to bladder tankC Alarm check valve model J-1 and trim Q Foam concentrate discharge pipingC.01 Water supply control valve S Retard chamberC.02 Water motor alarm V Auxiliary valve (Hydraulic valve release) (optional)

SP2.

3.10

.8/0

417/

en

These drawings are provided for guidance only and are not guaranteed to be up to date, accurate for every installation or to be compliant with local regulations.

Foam SystemsMultiple Foam Wet System - Pre-Piped (European)

TO SYSTEM

FROM WATER SUPPLY

FOAM/WATER

TO SYSTEM

FOAM/WATERSOLUTION

FOAM/WATER