floor plan | level 5...1 fifth floor plan tenant mechanical ... 1’-0” 31’-8” 6’-0” 0. 12...
TRANSCRIPT
35 CAMBRIDGE PARK DRIVE 11.08.16 | 19SGA COMMUNICATING. COLLABORATING. CREATING.
C
SGA COMMUNICATING. COLLABORATING. CREATING.
Spagnolo Gisness & Associates, Inc. 2016
35 Cambridgepark Drive | P-105
Fifth Floor PlanTHE DAVIS COMPANIES
1/8" = 1'-0"1 Fifth Floor Plan
TENANT
MECHANICAL PENTHOUSE
N
1’-9
”21
’-0”
21’-0
”21
’-0”
24’-0
”24
’-0”
24’-0
”
139’
-7”
2’-1
0”
45’-0” 45’-0”45’-0”22’-6”45’-0”45’-0”45’-0”
296’-0”
1’-9” 1’-9”
1’-0”
1’-0”
31’-8”
6’-0”
0 12 24 48
LOBBY
M
E
E
EC
LSCW
SS
ES FEEC
ES
SS
FLOOR PLAN | LEVEL 5
35 CAMBRIDGE PARK DRIVE 11.08.16 | 20SGA COMMUNICATING. COLLABORATING. CREATING.
C
SGA COMMUNICATING. COLLABORATING. CREATING.
Spagnolo Gisness & Associates, Inc. 2016
35 Cambridgepark Drive | P-106
Mechanical PenthouseTHE DAVIS COMPANIES
1/8" = 1'-0"1 Mechanical Penthouse Floor Plan
MECHANICAL ROOFTOP EQUIPMENT
MECHANICAL PENTHOUSE
N
0 12 24 48
31’-8”10’-3” 11’-4”
6’-3”
5’-0”
23’-6”
20’-10”
23’-6”
1’-0”
1’-0”
21’-0
”21
’-0”
21’-0
”24
’-0”
24’-0
”24
’-0”
139’
-7”
2’-1
0”
45’-0” 45’-0”45’-0”22’-6”45’-0”45’-0”45’-0”
296’-0”
1’-9” 1’-9”
1’-9
”
LOBBY
E
E
SS
ES FE
ES
SS
FLOOR PLAN | MECHANICAL PENTHOUSE
35 CAMBRIDGE PARK DRIVE 11.08.16 | 21SGA COMMUNICATING. COLLABORATING. CREATING.
EAST ELEVATION
metal panel roof screen
recessed metal channel
perforated, corrugated metal panels
spandrel glass
vision glass
pre-cast concrete
metal panel accents
see page 27 for detail elevation
vision glass
spandrel glass
vertical metal extrusion
11’-0
”14
’-6”
14’-6
”14
’-6”
14’-6
”20
’-0”
NOTES:
See page 6 for Southeast Day ViewSee page 7 for Southeast Night ViewSee page 29 for Retail Perspective
See page 30 for Entry Perspective See page 36 for Signage Location Plan See page 37 for Sign Family Overview 0 10 20 40
35 CAMBRIDGE PARK DRIVE 11.08.16 | 22SGA COMMUNICATING. COLLABORATING. CREATING.
SOUTH ELEVATION
metal panel roof screen
recessed metal channel
spandrel glass
vision glass
vertical metal extrusion
metal panel accent
cast in place foundation with precast sill at storefront
11’-0
”14
’-6”
14’-6
”14
’-6”
14’-6
”20
’-0”
see page 26 for detail elevation
see page 25 for detail elevation
0 10 20 40
NOTES:
See page 6 for Southeast Day ViewSee page 7 for Southeast Night ViewSee page 29 for Retail Perspective
See page 30 for Entry Perspective See page 36 for Signage Location Plan See page 37 for Sign Family Overview
35 CAMBRIDGE PARK DRIVE 11.08.16 | 23SGA COMMUNICATING. COLLABORATING. CREATING.
WEST ELEVATION
metal panel roof screen
metal panel accents
precast concrete
vision glassspandrel glass
11’-0
”14
’-6”
14’-6
”14
’-6”
14’-6
”20
’-0”
0 10 20 40
NOTES:
See page 6 for Southeast Day ViewSee page 7 for Southeast Night ViewSee page 29 for Retail Perspective
See page 30 for Entry Perspective See page 36 for Signage Location Plan See page 37 for Sign Family Overview
35 CAMBRIDGE PARK DRIVE 11.08.16 | 24SGA COMMUNICATING. COLLABORATING. CREATING.
NORTH ELEVATION
11’-0
”14
’-6”
14’-6
”14
’-6”
14’-6
”20
’-0”
metal panel roof screenarchitectural louversspandrel glass
vision glass
metal panel accents
precast concrete
0 10 20 40
NOTES:
See page 6 for Southeast Day ViewSee page 7 for Southeast Night ViewSee page 29 for Retail Perspective
See page 30 for Entry Perspective See page 36 for Signage Location Plan See page 37 for Sign Family Overview
35 CAMBRIDGE PARK DRIVE 11.08.16 | 25SGA COMMUNICATING. COLLABORATING. CREATING.
ENLARGED BAY ELEVATIONS | MATERIALS | SOUTH ELEVATION
GLAZING
ACCENT FINS
METAL PANEL WITH COPPER FINISH
0 5 10 20
35 CAMBRIDGE PARK DRIVE 11.08.16 | 26SGA COMMUNICATING. COLLABORATING. CREATING.
ENLARGED BAY ELEVATIONS | MATERIALS | SOUTH ELEVATION AT ENTRY
0 5 10 20
GLAZING
ACCENT FINS
METAL PANEL WITH COPPER FINISH
35 CAMBRIDGE PARK DRIVE 11.08.16 | 27SGA COMMUNICATING. COLLABORATING. CREATING.
ENLARGED BAY ELEVATIONS | MATERIALS | EAST ELEVATION
METAL PANEL
SPANDREL GLAZING
PRECAST CONCRETE
0 5 10 20
35 CAMBRIDGE PARK DRIVE 11.08.16 | 28SGA COMMUNICATING. COLLABORATING. CREATING.
PUBLIC REALM PERSPECTIVE
N
35 CAMBRIDGE PARK DRIVE 11.08.16 | 29SGA COMMUNICATING. COLLABORATING. CREATING.
WEST RETAIL PERSPECTIVE
N
35 CAMBRIDGE PARK DRIVE 11.08.16 | 30SGA COMMUNICATING. COLLABORATING. CREATING.
ENTRY PERSPECTIVE
N
35 CAMBRIDGE PARK DRIVE 11.08.16 | 31SGA COMMUNICATING. COLLABORATING. CREATING.
LOADING DOCK PERSPECTIVE
N
35 CAMBRIDGE PARK DRIVE 11.08.16 | 32SGA COMMUNICATING. COLLABORATING. CREATING.
MECHANICAL PENTHOUSE
FIFTH FLOOR
FOURTH FLOOR
THIRD FLOOR
SECOND FLOOR
FIRST FLOOR
150 CPD+/- 115’- 0”
100 CPD+/- 70’- 0”
36 CPD+/- 30’-0”
32 CPD+/- 16’- 0”
155 CPD+/- 52’- 0”
200 CPD+/- 120’- 0”
MBTA STATION+/- 60’- 0”
87 CPD+/- 24’- 0”
125 CPD+/- 95’- 0”
165 CPD+/- 75’- 0”
30 CPD+/- 95’- 0”
160 CPD+/- 75’-0”
35 CPD
ZONING HEIGHT
approximate heights of neighboringbuildings (to highest point)
BUILDING CROSS SECTION
hatched area indicates profile of existing building
N
11’-0
”14
’-6”
54’-6
”
69’-0
”
14’-6
”14
’-6”
14’-6
”20
’-0”
0 10 20 40
35 CAMBRIDGE PARK DRIVE 11.08.16 | 33SGA COMMUNICATING. COLLABORATING. CREATING.
BUILDING LONGITUDINAL SECTION
MECHANICAL PENTHOUSEMECHANICAL PENTHOUSE
FIFTH FLOOR
FOURTH FLOOR
THIRD FLOOR
SECOND FLOOR
FIRST FLOOR
N
35 CPD
11’-0
”14
’-6”
14’-6
”14
’-6”
14’-6
”20
’-0”
ZONING HEIGHT
69’-0
”
0 10 20 40
35 CAMBRIDGE PARK DRIVE 11.08.16 | 34SGA COMMUNICATING. COLLABORATING. CREATING.
GARAGE DIAGRAMS
bicycle parking room
electrical equipmentswitch gear room
UNDERGROUND NON-PARKING AREA
N
0 30 60 120
TOTAL PARKING
GENERAL 320 SPACESHANDICAP 9 SPACES SITE (H/C/ VAN) 2 SPACESTOTAL 331 SPACESTOTAL REMOVED 20 SPACES
THIRD FLOOR GARAGE PLAN
GENERAL 64 SPACESTOTAL 64 SPACESTOTAL REMOVED 6 SPACES
SECOND FLOOR GARAGE PLAN
GENERAL 106 SPACESTOTAL 106 SPACESTOTAL REMOVED 3 SPACES
LOWER FLOOR GARAGE PLAN
GENERAL 49 SPACESHANDICAP 7 SPACESTOTAL 56 SPACESTOTAL REMOVED 11 SPACES
LOWER FLOOR GARAGE PLAN
GENERAL 101 SPACESHANDICAP 2 SPACESTOTAL 103 SPACES
35 CAMBRIDGE PARK DRIVE 11.08.16 | 35SGA COMMUNICATING. COLLABORATING. CREATING.
BICYCLE FACILITY PLANS
N
0 5 10 20
5’-0
” TY
P
PEDESTRIAN ACCESS AISLE
PED
ESTR
IAN
AC
CES
S A
ISLE
bicycle repair station
bicycle repair station
tandembicycles
benches
lockers
PARKING GARAGE
BICYCLE RACKS
BIC
YCLE
RAC
KS
5’-0” TYP
4’-0” MIN 6’-0” MIN
3’-0” MIN
3’-0
” M
IN
TYPICAL EXTERIOR BICYCLE PARKING WITH RACKS ALIGNED BY SIDEBicycle racks will comply with Cambridge Zoning Ordinance Article 6.100
3’-0”
TYP
4’-0
”4’
-0”
MIN
MIN
BICYCLE RACKS
3’-0”
TYP
4’-0
”4’
-0”
MIN
MIN
BICYCLE RACKS
4’-0” M
IN
4’-0” M
IN
4’-0” MIN
4’-0” MIN
35 CAMBRIDGE PARK DRIVE 11.08.16 | 36SGA COMMUNICATING. COLLABORATING. CREATING.
SIGN LOCATION PLAN
N
SIGNAGE KEY
FREESTANDING MONUMENT
FREESTANDING DIRECTIONAL SIGN
PROJECTING RETAIL SIGN
PROJECTING ADDRESS SIGN
WALL SIGN BUILDING ID
WALL SIGN RETAIL ID
CAMBRIDGE PARK DRIVE
PARKING GARAGE ALEW
IFE STATION
ACC
ESS ROA
D
35 CAMBRIDGE PARK DRIVE
139’
-7”
296’-0”
UP
C
SGA COMMUNICATING. COLLABORATING. CREATING.
Spagnolo Gisness & Associates, Inc. 2016
35 Cambridge Park Drive | P-101
First Floor PlanTHE DAVIS COMPANIES
0 20 40 80