eurocode design midas gen

60
1 Introduction RC Design RC Frame & Wall Design RC Capacity Design Meshed Slab & Wall Design Steel Design Steel Code Check Steel Optimal Design General Section Designer BIM 02 06 06 27 37 43 43 56 58 63

Upload: kdb92uce

Post on 26-Nov-2015

719 views

Category:

Documents


171 download

DESCRIPTION

midas Gen

TRANSCRIPT

  • 1Introduction

    RC Design

    RC Frame & Wall Design

    RC Capacity Design

    Meshed Slab & Wall Design

    Steel Design

    Steel Code Check

    Steel Optimal Design

    General Section Designer

    BIM

    02

    06

    06

    27

    37

    43

    43

    56

    58

    63

  • 2One Stop Solution for Building and General StructuresDesign Procedure About midas Gen

    Seismic Specific Functionality Static Seismic Loads

    Response Spectrum Analysis

    Time History Analysis (Linear & Non-linear)

    Base Isolators and Dampers

    Pushover Analysis

    Fiber Analysis

    Capacity Design: Eurocode 8, NTC2008

    Comprehensive Design RC Design: ACI318, Eurocode 2 & 8, BS8110, IS:456 & 13920, CSA-A23.3,

    GB50010, AIJ-WSD, TWN-USD,

    Steel Design: AISC-ASD & LRFD, AISI-CFSD, Eurocode 3, BS5950, IS:800,

    CSA-S16, GBJ17 & GB50017, AIJ-ASD, TWN-ASD & LSD,

    SRC Design: SSRC, JGJ138, CECS28, AIJ-SRC, TWN-SRC

    Footing Design: ACI381, BS8110

    Slab & Wall Design: Eurocode 2

    Capacity Design: Eurocode 8, NTC2008

    High-rise Specific Functionality 3-D Column Shortening Reflecting change in Modulus, Creep and Shrinkage

    Construction Stage Analysis accounting for change in geometry, supports

    and loadings

    Building model generation wizard

    Automatic mass conversion

    Material stiffness changes for cracked section

    Intuitive User Interface Works Tree (Input summary with powerful modeling capabilities)

    Models created and changed with ease

    Floor Loads defined by area and on inclined plane

    Built-in Section property Calculator

    Tekla Structures, Revit Structures & STAAD interfaces

  • One Stop Solution for Building and General Structures

    3

    Design functions in midas Gen

    Design Type

    Steel : Steel code check

    Steel Optimal Design / Displacement Optimal Design

    Concrete : Concrete code design

    Concrete code check

    RC Capacity Design

    Meshed Slab/ Wall Design

    Footing : design

    Steel

    RC

    Footing

    Design Procedure

  • One Stop Solution for Building and General Structures

    4

    Design Procedure Introduction

    Available Design Code

    RC Design Steel Design SRC Design

    ACI318 AISC-LRFD SSRC79

    Eurocode 2, Eurocode 8 AISC-ASD JGJ138

    BS8110 AISI-CFSD CECS28

    IS:456 & IS:13920 Eurocode 3 AIJ-SRC

    CSA-A23.3 BS5950 TWN-SRC

    NTC IS:800 AIK-SRC

    GB50010 CSA-S16 KSSC-CFT

    AIJ-WSD GBJ17, GB50017 Footing Design

    TWN-USD AIJ-ASD ACI318

    AIK-USD, WSD TWN-ASD, LSD BS8110

    KSCE-USD AIK-ASD, LSD, CFSD Slab Design

    KCI-USD KSCE-ASD Eurocode 2

    KSSC-ASD

    Batch Wall

    Combined Footing

    Gen 2013 (v2.1)

    Design+ for Eurocode - Releasing in Nov, 2013

  • One Stop Solution for Building and General Structures

    5

    Design Procedure

    Eurocode Implementation Status

    Introduction

    Material DBConcrete Material DB Eurocode 2:2004

    Steel Material DB Eurocode 3:2005

    Section DB Steel Section DB UNI, BS, DIN

    Load

    Static Wind load Eurocode 1:2005

    Static Seismic Load Eurocode 8:2004

    Response Spectrum Function Eurocode 8:2004

    Pushover Analysis

    Masonry Pushover OPCM3431

    RC Pushover Eurocode 8:2004

    Steel Pushover Eurocode 8:2004

    Design

    Load Combination Eurocode 0:2002

    Concrete Frame Design (ULS & SLS) Eurocode 2:2004

    Concrete Capacity DesignEurocode 8:2004

    NTC 2012

    Steel Frame Design (ULS & SLS) Eurocode 3:2005

    Slab/Wall Design (ULS & SLS) Eurocode 2:2004

  • 6RC Frame & Wall Design

    Introduction

    RC Design

    RC Frame & Wall Design

    RC Capacity Design

    Meshed Slab & Wall Design

    Steel Design

    Steel Code Check

    Steel Optimal Design

    General Section Designer

    BIM

    02

    06

    06

    27

    37

    43

    43

    56

    58

    63

  • One Stop Solution for Building and General Structures

    7

    Design Procedure

    Auto calculation procedure for effective length factor(1) Calculate the stiffness, S (=EI/L), of the members which are connected to the Member a.

    Fixed joint: S = (1/1.5)* EI/LHinge: S= (1/2.0)* EI/LWhere, E: Modulus of elasticity

    I: Moment of inertia of sectionL: Span length of flexural member measured from center to center of joints

    (2) Calculate i and j. is the ratio of (EI/lc) of compression members to (EI/l) of flexural membersin a plane at one end of a compression member.

    (3) Calculate the solution, X, in the stability equation below.Braced / Non-sway frames

    Unbraced / Sway frames

    Where, : Ratio of (EI/lc) of compression members to (EI/l) of flexural members in a planeat one end of a compression member.

    (4) Calculate the effective length factor, K

    General Design Parameter Definition of Frame

    `

    `

    Design > General Design Parameter

    > Definition of Frame

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    8

    Design Procedure

    Design > General Design Parameter > Member Assignment

    When one member is divided into several elements,

    separate elements can be designed as one member

    using the Member Assignment function.

    Member Assignment results can be displayed as

    Contours by checking on the Member option in the

    Design tab of the Display dialog.

    General Design Parameter Member Assignment

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    9

    Design Procedure

    General Design Parameter Unbraced Length

    Design > General Design Parameter > Unbraced Length

    Axial forces or bending moments are calculated using the unbraced

    lengths for buckling about the strong (y-axis) and weak (z-axis) axes of the

    selected compression members when the members are under the loads.

    Slenderness ratio about the strong axis: (KL/r)y = (Ky Ly) / roy

    Slenderness ratio about the weak axis: (KL/r)z = (Kz Lz) / roz

    Where,

    Ly, Lz : Unbraced length about the strong and weak axes

    Ky, Kz : Effective length factor about the strong and weak axes

    roy, roz : radius of gyration of area about the strong and weak axes

    When members are defined by Member Assignment, Unbraced lengths

    about the strong axis (y-Axis) and weak axis (z-Axis) are automatically

    calculated by the program considering the connectivity of the members

    (e.g. connections and support conditions)

    x

    y

    z

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    10

    Design Procedure

    General Design Parameter Laterally Unbraced Length

    Design > General Design Parameter > Unbraced Length

    Neutral axis in shear

    Fig 1. Lateral torsional buckling Fig 2. Laterally unbraced length

    The laterally unbraced length is the unbraced length for lateral buckling about the elements local x-axis when the members are under the

    axial loads. The laterally unbraced length is required to calculate the design flexural strength considering lateral buckling.

    a b

    Laterally unbraced length : a + b

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    11

    Design Procedure

    Beam Design Rigid End Offset

    Beam End Offset

    Define Rigid End Offset Distance or take into account the Joint Eccentricity with respect to the GCS or element's local coordinate system at both ends

    of beam elements.

    Panel Zone Effect

    Automatically consider the stiffness effects of the Panel Zone where column members and girder members (horizontal elements connected to

    columns) of steel structures are connected. Panel Zone Effects are reflected in the beam elements.

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    12

    Design Procedure

    RC Design Limitation (Section)

    Available Section Types

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    13

    Design Procedure

    Generate Load Combination

    General TabCombine unit load cases to evaluate serviceability or analysis resultsirrespective of design codes.

    Concrete Design TabEnter the load combinations for designing RC members according to the RCdesign codes.

    Results > Load Combination

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    14

    Design Procedure

    Load Combination Type and Serviceability Parameter

    RC Frame & Wall Design

    Load cases will be classified as Characteristic, Frequent, or Quasi-permanent, and they will beautomatically classified when using Auto-generation.Short/Long term Load Case is assigned to compare them with proper allowable stresses.

  • One Stop Solution for Building and General Structures

    15

    Design Procedure

    Partial Safety Factors

    RC Frame & Wall Design

    [Partial Safety Factor for Concrete] [Partial Safety Factor for Steel]

  • One Stop Solution for Building and General Structures

    16

    Design Procedure

    Design

    Based on the section size and the factored load obtained from the most unfavorable load combination, rebar data such as rebar size and

    spacing are determined. Therefore, design can be performed when the section size is determined without rebar data.

    Checking

    Strength verification can be performed by automatic design or by using the information of rebars (diameter, number and design

    parameters) entered by the user. The results appear in blue when the strength verifications for the given section properties and rebars

    are satisfactory, otherwise they appear in red.

    Difference between Design and Checking

    Automatic Design by Gen

    Manual Calculation

    Design

    Automatic Rebar update

    Modify Rebar Input Data

    Rebar InputStrength Verification with Updated Rebars

    Check

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    17

    Design Procedure

    Bending without axial force:

    Ultimate Limit State Design (1)

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    18

    Design Procedure

    Bending with axial force:

    RC Frame & Wall Design

    Ultimate Limit State Design (2)

  • One Stop Solution for Building and General Structures

    19

    Design Procedure

    Bending with axial force:

    Ultimate Limit State Design (3)

    RC Frame & Wall Design

    Considering second order effect in analysis

  • One Stop Solution for Building and General Structures

    20

    Design Procedure RC Frame & Wall Design

    Ultimate Limit State Design (3)

  • One Stop Solution for Building and General Structures

    21

    Design Procedure

    Shear force:

    RC Frame & Wall Design

    Ultimate Limit State Design (4)

  • One Stop Solution for Building and General Structures

    22

    Design Procedure

    Detailing of Members (1)

    The following conditions are applied to Beam design:

    The following conditions are applied to Column design:

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    23

    Design Procedure

    Detailing of Members (2)

    The following conditions are applied to Wall design:

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    24

    Design Procedure

    [Detail Report]

    [Graphic Report]

    Check Design Results

    [PM Curve]

    RC Frame & Wall Design

    [Design Result Dialog Box]

  • One Stop Solution for Building and General Structures

    25

    Design Procedure

    Rebar Input & Modification

    RC Frame & Wall Design

  • One Stop Solution for Building and General Structures

    26

    Design Procedure

    When the members are overstressed, a different section size can be applied

    for the design without performing the analysis again.

    In order to see the effect of the modified section data in the design result,

    re-perform the design.

    Design > Section for Design

    `

    Section for Design

    RC Frame & Wall Design

  • 27

    Meshed Slab & Wall Design

    Introduction

    RC Design

    RC Frame & Wall Design

    RC Capacity Design

    Meshed Slab & Wall Design

    Steel Design

    Steel Code Check

    Steel Optimal Design

    General Section Designer

    BIM

    02

    06

    06

    27

    37

    43

    43

    56

    58

    63

  • One Stop Solution for Building and General Structures

    28

    Design Procedure

    Meshed slab and wall design

    Slab and wall design for meshed plate elements as per Eurocode2-1-1:2004 Slab design for non-orthogonal reinforcement directions based on the Wood-Armer formula Smooth moment and shear forces Automatic generation of Static wind and seismic loads for flexible floors Detailing for local ductility

    Wall design

    Slab serviceability checking

    Punching shear check result

    Slab flexural design

    Meshed slab and wall design

  • One Stop Solution for Building and General Structures

    29

    Design Procedure

    Slab Flexural design : Required rebar area Rebar type and Spacing

    Slab Flexural Design

    Meshed slab and wall design

    The following results are provided from flexural design:

    Rebar spacing and diameter

    Required rebar area

    Required rebar ratio

    Resistance ratio

    Wood-Armer Moment

    Detailed Report and Wood-Armer Moment Table

  • One Stop Solution for Building and General Structures

    30

    Design Procedure

    Slab/Wall Rebars for Checking

    Slab/Wall Rebars for CheckingDefine reinforcement direction

    Meshed slab and wall design

  • One Stop Solution for Building and General Structures

    31

    Design Procedure

    From the analysis results, following plate forces about the local axis are calculated:mxx, myy, mxy

    In order to calculate design forces in the reinforcement direction, angle and will be taken as following figure:

    x, y: local axis of plate element1, 2: reinforcement direction: angle between local x-direction and reinforcement direction 1: angle between reinforcement direction 1 and reinforcement direction 2

    Firstly, internal forces (mxx, myy and mxy) are transformed into the a-b coordinate system.

    Wood-Armer moment

    Then, Wood-Armer moments are calculated as follows:

    Meshed slab and wall design

  • One Stop Solution for Building and General Structures

    32

    Design Procedure

    Punching Shear Checking

    Meshed slab and wall design

    Punching shear check results at the critical perimeter of

    slab supports or the loaded points of concentrated loads

    One-way shear check results along the user-defined

    Shear Check Lines

    Case 1. vEd : plate stress from analysis

    EdEd

    i

    Vv

    u d Case 2.

    Shear stress for each side

    Detailed report

    V_Ed < V_Rd,c : section is safe in punching shear

    V_Ed > V_Rd,c : provide shear reinforcement.

    Asw/sr = (v_Ed-0.75*v_Rd_c)*(u1*d) / (1.5*d*fywd_ef)

    Shear stress at the critical perimeter

  • One Stop Solution for Building and General Structures

    33

    Design Procedure

    The maximum shear force is calculated by multiplying V_Ed with shear enhancement factor . The value of is different for different columns. (as given in the code)

    Punching Shear Check

    Meshed slab and wall design

  • One Stop Solution for Building and General Structures

    34

    Design Procedure

    Slab Serviceability Check

    Meshed slab and wall design

    Stress Checking

    Crack Control

    Deflection

    Stress Checking

    Both compressive stress in concrete and tensile stress in

    reinforcement is checked with the stress limitation specified in

    the Serviceability Parameters dialog box.

    When plate force exceeds cracked moment, the program can

    automatically consider the cracked section in stress checking.

    Crack Control

    Crack width, minimum rebar area to control the crack, maximum

    bar spacing, and maximum bar diameter for crack can be

    checked in the contour as well as the detailed report.

    Deflection

    Deflection for un-cracked section can be calculated considering

    long-term deflection due to creep. Deflection for cracked section

    can be provided in the upcoming version.

  • One Stop Solution for Building and General Structures

    35

    Design Procedure

    Cracked Section Analysis

    Cracked section analysis for deflection check Long-term effect considering creep coefficient

    Deflection Check Results by Cracked Section Analysis

    Meshed slab and wall design

    eff cr g

    M M M(1 )

    EI EI EI

    eff cr g

    1 1 1(1 )

    I I I

    2crM1 ( )M

    ' 0.5' is applied(long termloading).

    2

    ctm

    cr

    f bhM

    6

    32 s

    cr s c c

    c

    E 1I A (d d ) bd

    E 3

    2

    s s s s s s c,eff

    c

    c,eff

    A E (A E ) 2bA E E dd

    bE

  • One Stop Solution for Building and General Structures

    36

    Design Procedure

    Wall Design

    Meshed slab and wall design

    Members requiring reinforcement

    In locations where Edy is tensile or Edx Edy 2

    Edxy

    Members not requiring reinforcement

    In locations where Edx and Edy are both compressive and Edx Edy >

    2Edxy

    Limitation in concrete stress

    cd fcd

    Wall design results are provided in contour, detailed

    report, and design force table. Also, concrete stress (cd)

    can be checked with fcd.

    The following results are provided from wall design:

    Rebar spacing and diameter

    Required rebar area & Required rebar ratio

    Resistance ratio

  • 37

    RC Capacity Design

    Introduction

    RC Design

    RC Frame & Wall Design

    RC Capacity Design

    Meshed Slab & Wall Design

    Steel Design

    Steel Code Check

    Steel Optimal Design

    General Section Designer

    BIM

    02

    06

    06

    27

    37

    43

    43

    56

    58

    63

  • One Stop Solution for Building and General Structures

    38

    Design Procedure

    Seismic Design procedure as per EN1998-1:2004

    RC Capacity Design

    Performance Requirement

    Ground Condition

    Seismic Action

    Combination of Seismic Action

    Criteria for Structural Regularity

    Seismic Analysis

    Safety Verification

    Capacity Design & Detailing

    Seismic ZoneRepresentation of seismic action

    [Method of Analysis]Lateral Force method of AnalysisModal Response Spectrum AnalysisPushover AnalysisInelastic Time History Analysis

  • One Stop Solution for Building and General Structures

    39

    Design Procedure

    Capacity Design Feature

    structures to provide the appropriate amount of ductility in the corresponding ductility classes. Automatic capacity design capability for beam, column, wall and beam-column joint EN 1998-1: 2004 (DCM/DCH), NTC2008 (CD B, CD A), ACI318-05 Design action effects are calculated in accordance with the capacity design rule. Special provision for

    ductile primary seismic walls is considered. Detailing for local ductility is considered.

    - max/min reinforcement ratio of the tension zone- the spacing of hoops within the critical region- mechanical volumetric ratio of confining hoops with the critical regions

    Capacity design shear forces on beams

    Define ductility class and check design results Design envelope moments in walls

    RC Capacity Design

  • One Stop Solution for Building and General Structures

    40

    Design Procedure

    Design member forces (Design moments)

    Where,

    MRb: Beam moment resistance

    Mce : column member force due to seismic load case

    RC Capacity Design

  • One Stop Solution for Building and General Structures

    41

    Design Procedure

    Design member forces (Design shear forces)

    Capacity design values of shear forces on beams

    Capacity design shear force in columns

    Where, MRb: Beam moment resistance

    MRc: Column moment resistance (calcul

    ated using same axial force ratio in

    PM interaction curve)

    Mce: Bending moment of column due to

    seismic load case

    RC Capacity Design

  • One Stop Solution for Building and General Structures

    42

    Design Procedure

    Design envelope for bending moments in slender walls Design envelope of the shear forces in the walls of a dual system

    Design member forces (Wall design forces)

    Wall systems Dual systems

    RC Capacity Design

  • 43

    Steel Code Check

    Introduction

    RC Design

    RC Frame & Wall Design

    RC Capacity Design

    Meshed Slab & Wall Design

    Steel Design

    Steel Code Check

    Steel Optimal Design

    General Section Designer

    BIM

    02

    06

    06

    27

    37

    43

    43

    56

    58

    63

  • One Stop Solution for Building and General Structures

    44

    Design Procedure

    Applicable Sections of Ultimate Limit State Check Limitation

    Steel Code Check

    Cross section

    Limit States

    Yielding Flexural Buckling

    Shear BucklingLTB

    Strong axis Weak axis

    I sectionDoubly Symmetric N/A

    Singly Symmetric N/A N/A

    Box (2) N/A

    Angle N/A N/A N/A

    Channel N/A N/A

    Tee N/A N/A N/A

    Double Angle N/A N/A N/A

    Double Channel N/A N/A

    Pipe N/A N/A N/A

    Solid Rectangle N/A N/A N/A

    Solid Round N/A N/A N/A

    U-Rib N/A N/A N/A N/A N/A

  • One Stop Solution for Building and General Structures

    45

    Design Procedure

    Resistance of cross-sections:

    Ultimate Limit State Design (1)

    Steel Code Check

  • One Stop Solution for Building and General Structures

    46

    Design Procedure

    Resistance of cross-sections:

    Ultimate Limit State Design (2)

    Steel Code Check

  • One Stop Solution for Building and General Structures

    47

    Design Procedure

    Resistance of cross-sections:

    Ultimate Limit State Design (3)

    Steel Code Check

  • One Stop Solution for Building and General Structures

    48

    Design Procedure

    Steel Checking Design Results

    Change

    Propose sections satisfying the selected element conditions.

    Steel Code Check

  • 49

    Steel Optimal Design

    Introduction

    RC Design

    RC Frame & Wall Design

    RC Capacity Design

    Meshed Slab & Wall Design

    Steel Design

    Steel Code Check

    Steel Optimal Design

    General Section Designer

    BIM

    02

    06

    06

    27

    37

    43

    43

    56

    58

    63

  • One Stop Solution for Building and General Structures

    50

    Design Procedure

    As shown in the Optimal Design Result (Average Ratio) graph, average ratio of column members is about 0.4 since

    all the sections within 5% of the entered dimensions are examined for strength verification. Therefore, we will

    reduce the section dimension and re-perform Steel Optimal Design.All the sections within 5% of the

    entered dimensions are examined for strength verification.

    If the entry is "0", all dimensions are searched.

    Steel Optimal Design Design Results

    Steel Optimal Design

  • 51

    General Section Designer

    Introduction

    RC Design

    RC Frame & Wall Design

    RC Capacity Design

    Meshed Slab & Wall Design

    Steel Design

    Steel Code Check

    Steel Optimal Design

    General Section Designer

    BIM

    02

    06

    06

    27

    37

    43

    43

    56

    58

    63

  • One Stop Solution for Building and General Structures

    52

    Design Procedure

    Definition of any Irregular cross-section.

    Calculation of Section Properties.

    Generation of P-M, P-My-Mz, M-M interaction curves.

    Calculation of Section Capacity in flexure.

    Calculation of Safety Ratio based on the member forces.

    Generation of Moment-Curvature curve.

    Plot of Stress Contours for all the cross-section.

    All the above features are supported for

    RC Sections

    Steel Sections

    Composite Sections

    Scope of GSD

    General Section Designer

    Stress Contour

    Moment- Curvature

    3D PM Interaction curve

  • One Stop Solution for Building and General Structures

    53

    Design Procedure General Section Designer

    Generating Report

    Report in MS-Excel format is generated on clicking [Report] button in any of the result pages.

    It is saved in the same folder as that of the model file.

    Any item can be added to the report by clicking the [Report] button.

  • One Stop Solution for Building and General Structures

    54

    Design Procedure

    Shapes created in AutoCAD can be imported into GSD to create sections.

    Rebar coordinates can also be imported as a separate layer.

    General Section Designer

    Importing AutoCAD dxf files

  • One Stop Solution for Building and General Structures

    55

    Design Procedure General Section Designer

    Link between midas Gen to GSD

    Connect a link with midas Gen or Civil to import a cross-section shape, material properties,

    and member forces for the desired element position. The user can also export section

    properties and cross-section shape of a general section from GSD to mdias Gen or Civil.

    midas GSD can import the following types of the sections from midas Gen and Civil:

    DB/User, Value, SRC, and Tapered type sections.

  • 56

    Building Information Modeling

    Introduction

    RC Design

    RC Frame & Wall Design

    RC Capacity Design

    Meshed Slab & Wall Design

    Steel Design

    Steel Code Check

    Steel Optimal Design

    General Section Designer

    BIM

    02

    06

    06

    27

    37

    43

    43

    56

    58

    63

  • One Stop Solution for Building and General Structures

    57

    Midas Link for Revit Structure supports the following workflows:

    (1) Send the Revit Structure analytical model to midas Gen.

    (2) Import the MGT file of the Revit model in midas Gen.

    (3) Export the midas model file to the MGT file.

    (4) Update the Revit Structure model from midas Gen

    Revit interface

    Building Information Modeling

  • One Stop Solution for Building and General Structures

    58

    Building Information Modeling

  • One Stop Solution for Building and General Structures

    59

    Category FeaturesRevit to

    midas Gen

    Material

    Concrete v

    Steel v

    Pre Cast Concrete v

    Section

    Concrete v

    Steel v

    SRC N/A

    Member

    ColumnVertical Column v

    Inclined Column v

    Beam

    Straight Beam v

    Curved Beam v

    Inclined Beam v

    Wall

    Straight Wall v

    Curved Wall v

    Inclined Wall v

    Masonry Wall N/A

    Wall Opening v

    Brace v

    Truss(Top chord, Bottom chord, and Web) v

    Slab v (Import only)

    Building Information Modeling

    Category FeaturesRevit to

    midas Gen

    Boundary

    Support(Hinge, Roller, Fixed) v

    Beam End Release v

    Section Offset N/A

    Static Load

    Self Weight N/A

    Dead Load v

    Live Load v

    Wind Load v

    Seismic Load v

    Temperature Load v

    Snow Load v

    Accidental Load v

    Live Load on the roof v

    Point Load , Hosted Point Load v

    Line Load , Hosted Line Load v

    Area Load v

    Hosted Area Load N/A

    Load Combination

    Load Combination v

    Applicable data for MIDAS Link for Revit Structure

  • One Stop Solution for Building and General Structures

    60

    Building Information Modeling

    What is Updated from midas Gen to Revit Structure

    Sections

    If assigned section is changed to the other section pre-defined in the model, the corresponding element in Revit will be updated accordingly.

    If assigned section is changed to the other section newly added in midas Gen, the corresponding element in Revit will be assigned to a default

    section (arbitrary section which has a same material type in a model).

    Delete Elements

    If an element is deleted in midas Gen, the corresponding element in Revit will be deleted accordingly.

    Move Elements

    If an element is moved in midas Gen, the corresponding frame element or column in Revit will be moved accordingly.

    Add Elements

    If a beam element (solid box section only) is newly added, a corresponding element in Revit will be added accordingly.

    Change Beta-Angle

    If beta-angle in a beam element is changed, a corresponding element in Revit will be updated accordingly.

    Materials

    If material data assigned to an element is modified, a corresponding element in Revit will be assigned to a default material (arbitrary material existed

    in Revit).