0 Copyright Fujitsu Technology Solutions, Release September 2011
ETERNUS DX60 S2
Product Introduction
Product Introduction ETERNUS DX60 S2
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Highlights Low environmental impact Highly scalable & versatile connectivity User friendly management systems Outstanding reliability
1
Overview
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
ETERNUS DX60 ETERNUS DX60 S2
Number of Controllers 1 or 2
Cache Capacity per system 2 GB (1 GB per CM)
CPU 800 MHz 1.2 GHz
Cache Data backup Write back to NAND Flash Memory powered by SCU
Cache Hold Time No Limitation
Host Interfaces
FC (2.5" and 3.5") 4 Gbps
iSCSI (2.5" and 3.5") 1 Gbps
SAS (2.5" and 3.5") 3 Gbps
Drive Types SAS / Nearline SAS (3 Gbps)
RAID Levels 0,1,1+0,5,5+0, 6
Maximum number of HDDs Number of HDD / Enclosure
3.5” 24 (12 in 2U)
2.5” 24 (24 in 2U)
Maximum number of LUNs 512
Maximum number of HBAs 64 (16/port)
RAID Migration Yes
Base Copy Functions SnapOPC+ or QuickOPC
Optional Copy Functions SnapOPC+, OPC, QuickOPC, EC,
Encryption Yes
Eco-mode Yes
Supported OS Windows, Linux, VMware, Unix
2
Optional Modules Flexible response to business expansion 2.5" configuration
• 2.5" Controller Enclosure • Up to 24 2.5" disk drives
• Maximum system capacity 21.6 TB (SAS)
3.5" configuration • 3.5" Controller Enclosure
• Up to 12 3.5" disk drives • Maximum 36 TB (Nearline-SAS)
• 3.5" Drive Enclosure • Up to 12 3.5" disk drives
• Maximum of 24 disks (12 in CE + 12 in DE) • Maximum total system capacity 72 TB (Nearline-SAS)
Single controller system can be expanded to a dual controller system
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2 3
Disk Drives (1) Support for high performance disk drives (15,000 rpm) and
large capacity disk drives suitable for backup 3.5"
• SAS disk drives (15,000 rpm, 3 Gbit/s) • 600 GB / 450 GB / 300 GB
• Nearline SAS drives (7200 rpm, 3 Gbit/s) • 3 TB / 2 TB / 1 TB
2.5" • SAS disk drives (10,000 rpm, 3 Gbit/s)
• 900 GB / 600 GB / 450 GB / 300 GB SSD not supported
Disk LED
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
DISK READY Green: Normal status Blinking green: Normal operation
DISK FAULT Orange: Error status Blinking orange: Disk locator
DISK READY/FAULT Green: Normal status Blinking green: Normal operation Orange: Error status Blinking orange: Disk locator
4
Disk Drives (2) Possible to mix different types of disk drives Possible to choose the right kind of disk for every usage
• Nearline SAS for capacity • SAS for performance and reliability
DX60 S2 disk drives are physically not compatible with the other S2 models New disk capacities introduced with the DX60 S2 are not
compatible with the earlier DX Entry models
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
ETERNUS DX60 S2 SAS
Nearline SAS
5
RAID Levels RAID 1+0 is recommended for
business databases that are updated frequently Select RAID 1+0 for systems
that require high reliability and high performance
RAID 5 (RAID 5+0 if enough disks are available) or RAID 6 is recommended for data that requires less random performance or for systems where there is a high level of reading Global and dedicated Hot Spares are available, all disks can
be used except the system disks
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
RAID level Number of disks 1 2
1 + 0 4-24 (even number) 5 3-16 6 5-16
5 + 0 6-24 (even number)
6
ETERNUS DX Advanced Copy Functions (1) The Advanced Copy functions allow the DX to carry out high-
speed data copying operations on its own, without using any server resources Data Copies and Snapshots via GUI or CLI commands Data backup in a live data environment using the Microsoft Windows
Server Volume Shadow Copy Service (VSS) function with VSS-compatible backup software
Software solutions for quick data backup, restoration and replication ETERNUS SF Express
• Basic functionality comes free of charge ETERNUS SF AdvancedCopy Manager
• Requires a separate license
With both SF Express v14.2 and ACM v14.2 patch v14.2A needs to be installed for the DX60 S2
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2 7
ETERNUS DX Advanced Copy Functions (2) Free trial use before purchasing software license Able to use eight sessions
of Snapshot (SnapOPC+) for free
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
>xxxxxxx
Able to use Snapshots for free (up to eight sessions) ETERNUS DX60 S2
Standard With Local Copy license 1)
No. of sessions 8 512
Operation I/F GUI/CLI VSS Express GUI/CLI VSS Express ACM
Supp
orte
d fu
nctio
n
SnapOPC+ x x x x x x x
QuickOPC - x - - x x x
OPC - - - - - x x
EC - - - - - x x
Feature Copies without optional software
Meets various requirements using ISV backup software
Simplifies initial settings of copy
Copies without optional software
Meets various requirement in Windows environment using ISV backup software
Enables easy device management and backup
Supports various OS and ISV applications, and able to use all Advanced Copy functions
Express = ETERNUS SF Express ACM = ETERNUS SF Advanced Copy Manager VSS = Microsoft Windows Server Volume Shadow Copy Service No. of sessions = Max. number of copies to be executed at a time 1) Need to purchase the copy license separately
Step up Step up
8
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Identification The Serial Number is located on top left hand side of the shelf With both Controller Enclosure and Drive Enclosure the first two digits of
the serial number are 45... Two-digit Check Code can be found on a separate sticker by the
identification label • Default password for the
user account "f.ce" is "<check code><serial-no.>"
9
System Modules
Controller Enclosure for 2.5" Disks Controller Enclosure for 3.5" Disks Controller Modules Drive Enclosure
Product Introduction ETERNUS DX60 S2 Copyright Fujitsu Technology Solutions, Release September 2011 10
Controller Enclosure for 2.5" Disks Front view with bezel
Front view with bezel removed
Disk slot numbering
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Sys
tem
dis
k S
yste
m d
isk
Operation Panel
11
Controller Enclosure for 3.5" Disks Front view with bezel
Front view with bezel removed
Disk slot numbering
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
System disk System disk
12
Controller Enclosure Operation Panel Controller Enclosure for 2.5" disks
Controller Enclosure for 3.5" disks
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
AUTO POWER ON: Connected DE is always powered on OFF: Default setting
POWER Green: DC power supply OK READY Green: System is ready for use FAULT Orange: Error status Blinking orange: Preventive maintenance required IDENTIFY Blinking blue: Activated from Web GUI CACHE Green: Data in cache Blinking green: Cached data saved to NAND Flash
MODE SELECT ON: Connected DE is powered on with power switch OFF: Do not use IP RESET - Push once to toggle the Master CM - Push twice within two seconds to reset the LAN port settings
With flange cover Without flange cover
Power switch - Push four seconds to switch the system off
13
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Controller Enclosure Rear View
Power inlet
STATUS Green: Mains power supply OK, system on Blinking green: Mains power supply OK, system off Orange: PSU or fan in error status
PSU#1
CM#1
PSU#0
CM#0
Power cable strain relief
Module eject lever
14
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Controller Module Fibre Channel SCU STATUS Green: Normal status Blinking green: SCU is charging
IDENTIFY Blinking blue: Activated from Web GUI
DI OUT Green: Link to DE established
DI OUT Port RMT Port Not used
MNT Port
FC LINKUP / FAULT Green: Link to Host established Orange: Error status
FC Port 1
Unit Ready / Fault Green: Normal status Orange: Initial setup running or Error status
MASTER Green: This CM is set as Master
ACT LED Green: Sending or receiving data
LINK LED Green: Link established
Not used
FC Port 0 FC LINKUP / FAULT Green: Link to Host established Orange: Error status
15
Controller Module iSCSI
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
SCU STATUS Green: Normal status Blinking green: SCU is charging
IDENTIFY Blinking blue: Activated from Web GUI
DI OUT Green: Link to Drive Enclosure established
DI OUT Port RMT Port Not used
MNT Port
iSCSI Port 0 iSCSI Port 1
Unit Ready / Fault Green: Normal status Orange: Initial setup running or Error status
MASTER Green: This CM is set as Master
ACT LED Green: Sending or receiving data
LINK LED Green: Link established
Not used
ACT LED Green: Sending or receiving data
LINK LED Green: Link establishe
16
Controller Module SAS
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
SCU STATUS Green: Normal status Blinking green: SCU is charging
IDENTIFY Blinking blue: Activated from Web GUI
DI OUT Green: Link to Drive Enclosure established
DI OUT Port RMT Port Not used
MNT Port Unit Ready / Fault Green: Normal status Orange: Initial setup running or Error status
MASTER Green: This CM is set as Master
ACT LED Green: Sending or receiving data
LINK LED Green: Link established
Not used
SAS (HOST) LINKUP / FAULT Green: Link to Host established Orange: Error status
SAS Port 1
SAS Port 0 SAS (HOST) LINKUP / FAULT Green: Link to Host established Orange: Error status
17
Drive Enclosure for 3.5" Disks Front view with bezel
Front view with bezel removed
Disk slot numbering
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2 18
Drive Enclosure Operation Panel
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
AUTO POWER ON: Do not use OFF: Default setting
MODE SELECT ON: DE is powered on with power switch OFF: Do not use
Not used
POWER Green: DC power supply OK READY System is ready for use FAULT Orange: Error status Blinking orange: Preventive maintenance required IDENTIFY Blinking blue: Activated from Web GUI
With flange cover Without flange cover
Not used
19
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Drive Enclosure Rear View
PSU#1
EXP#1
PSU#0
EXP#0
DI IN Port Unit Ready / Fault Green: Normal status Orange: Initial setup running or Error status
DI (IN) LINKUP / FAULT Green: Link to CE established Orange: Error status
IDENTIFY Blinking blue: Activated from Web GUI
Not used
20
Product Features
Battery Free Cache Protection 8 Gbit Fiber Channel Interface High Availability and Advanced Data Protection Dynamic LUN Migration, LUN Concatenation and Logical
Device Expansion Data Encryption Eco-mode
Product Introduction ETERNUS DX60 S2 Copyright Fujitsu Technology Solutions, Release September 2011 21
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Block Diagram Controller Enclosure
Drive Enclosure
BP PSU PSU
PSU PSU BP
SCU
LSI
RoC Cache
Expander
Nonvolatile memory
Panel
Monitor PLD
CM#1
RoC
Expander
Cache LSI
Nonvolatile memory
SCU SCU
Monitor PLD
CM#0
EXP#0 EXP#1 Panel Monitor PLD
Monitor PLD Expander Expander
To Drive Enclosure
(SAS interface)
RAID-on-Chip (RAID Controller)
SAS Expander
Controller Interconnect
(PCI Express x4)
Host Interface (Fiber Channel, iSCSI or SAS)
System Capacitor Unit
Controller Module
22
Battery Free Cache Protection (1) Reduced maintenance window SCU* is maintenance free for 5 years
• Battery replacement was required every three years in the previous models
Avoid data loss during extended power outages Migrating cache data to a nonvolatile memory
ensures unlimited data retention time • Previously battery back up supported cache
data for approximately 96 hours
Cached write performance recovered almost immediately after power restoration SCU recharge time about three minutes
• Exact battery recovery time depends on how long the power has been unavailable
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
• SCU is a unit with electric double layer capacitor. Electric double layer capacitor has the advantages of being very resistant to degrading and by providing a short recharge time compared to traditional batteries.
Data Data
Migrate cache data to a nonvolatile memory at high speed through a
dedicated line
SCU
SCU* supplies power when power
fails
Nonvolatile memory
Memory LSI RoC Memory
23
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Battery Free Cache Protection (2) Technology comparison
Data Data
Migrate cache data to a nonvolatile memory at high speed through a
dedicated line
RoC Memory
BBU CM#0
Data
Power is supplied from BBU* to memory when power fails.
Cache data can be kept as long as the battery has power
Technology based on a BBU
BBU = Battery Backup Unit
Technology based on a SCU
SCU SCU supplies power
when power fails
Nonvolatile memory
Memory LSI RoC Memory
24
High Availability Duplicated components Basic configuration contains
always two Power Supplies The Controller Module can be
optionally duplicated
Components are hot swappable Hot expansion of disk drives Hot firmware upgrade
supported
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
PSU: Power Supply Unit , SCU: System Capacitor Unit, RoC: RAID-on-Chip
PSU PSU
PSU PSU
BP
BP
SCU
LSI RoC Cache
Expander
CM#0
NAND Flash
Monitor PLD
SCU
Base System
Expansion Shelf
CM#1
RoC
Expander
Cache LSI NAND Flash
SCU
Monitor PLD
Expander Expander EXP#0 EXP#1 Panel Monitor
PLD Monitor
PLD
Panel
25
Data Protection by Data Block Guard 8-byte check code is added to every 512-byte data to
control data integrity on the disk and in the cache Guarantees consistency of all stored data
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
WRITE READ
Apply Check Code
(2) (3)
(4)
DISK
User Data
CC: Check Code
A0 A1 A2
A0 A1 A2 CC CC CC
User Data A0 A1 A2
A0 A1 A2 CC CC CC
A0 A1 A2 CC CC CC
Controller Module
Written Data
ETERNUS DX
Write Check Code
Verify Check Code
(1)
Cache ECC Protected
Verify & delete Check Code (4)
(2)
(1)
(3)
26
Control of a Failed Disk Two different modes are supported Rebuild
• ETERNUS DX rebuilds the data of a failed drive from the remaining drives and writes it to a Hot Spare • When no Hot Spare is available
ETERNUS DX rebuilds the data after the defective drive is replaced
• Redundancy of the RAID Group is recovered after rebuild is completed
Copy Back • After redundancy of the RAID
Group is re-established, data is copied back from the Hot Spare to the replaced drive
Copyright Fujitsu, Release August 2011 Common Features ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2
HS
Disk replacement
Failed
Failed
Without redundancy
Recover redundancy
New
Without redundancy
Recover redundancy
Failed Disk replacement
New
Rebuild
Copy Back
Rebuild Failed
HS
27
Global and Dedicated Hot Spare Dedicated Hot Spare (DHS) disk Has to be assigned to a specific
RAID Group When a disk of a RAID Group with
a Dedicated HS fails, then this Dedicated HS is selected and used to rebuild the RAID Group
Global HS (GHS) Used by all RAID Groups When a disk in any RAID Group fails
and there is no Dedicated HS available, a Global HS is used to rebuild the RAID Group
Copyright Fujitsu, Release August 2011 Common Features ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2
GHS
DHS
DHS
: Global Hot Spare
: Dedicated Hot Spare for RAID Group D
: Dedicated Hot Spare for RAID Group E
ETERNUS DX S2
RAID Group D
RAID Group E DHS
DHS
Failed
RAID Group C
RAID Group B
RAID Group A GHS
28
Dynamic LUN Expansion The ETERNUS DX Series is able to expand the capacity of
LUN (Logical Unit Number) without stopping the operation
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Expand Logical device expansion
LUN Concatenation
LUN0 New
added drive Current
RAID Group RAID 5 (4+1)
LUN0 Unused area
Expand RAID Group by "Logical Device Expansion"
RAID Group now RAID 5 (5+1)
LUN0
Expand LUN0 capacity by "LUN concatenation"
RAID Group RAID 5 (5+1)
29
Logical Device Expansion Expand capacity (free space) of a RAID Group by adding
unused disk drives RAID level can be changed
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Expands
Existing RAID Group RAID 5 (3+1)
Unused disks not assigned to any RAID Group
Same RAID Group RAID 5 (5+1)
30
LUN Concatenation LUN capacity can be expanded by using LUN concatenation Consolidates unused areas in the same or across multiple
RAID Groups for efficient use of drives NOTE: After LUN Concatenation it may be necessary to adapt
the Operating System and/or application to recognize the increased LUN size Maximum LUN capacity is 32 TB Minimum LUN capacity is 1 GB Maximum number of LUNs that can be concatenated is 16 Able to mix different RAID levels
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
RAID 5 450 GB x4
LUN1 600 GB
RAID 5 450 GB x4
Unused area 1.2 TB
RAID 5 450 GB x4
LUN1 600 GB
RAID 5 450 GB x4
LUN0 1.2 TB Concatenate LUN2 600 GB
RAID Group 1 RAID Group 2
RAID-Grp1
RAID Group 2
LUN0 1.2 TB LUN2 with 1.8 TB
RAID Group 1
31
RAID Migration Enables data to be moved between different RAID Groups
without interrupting operation Migrate existing LUNs from a RAID Group to a different one Migration between different RAID levels RAID migration to expand LUN capacity Migration is transparent from server point of view
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Migrate data to large capacity drives
Migrate data to a high reliable RAID level
LUN 0
RAID 5 300 GB
Unused 600 GB
RAID Group 1
RAID Group 2
Unused 300 GB
LUN 0 RAID 5 600 GB
RAID Group 1
RAID Group 2
RAID 5 600 GB
Unused 600 GB
LUN 0
RAID Group 1
RAID Group 2
Unused 600 GB
RAID 1+0 600 GB
LUN 0 Mirroring
LUN 0
RAID Group 1
RAID Group 2
32
Data Encryption Fujitsu's unique encryption algorithm can be enabled via
ETERNUS Web GUI Encrypts user data in units
of LUN Both encrypted and unencrypted
data can exist in the same RAID Group
Possible to encrypt an existing unencrypted Volume For redundancy, the Data
Encryption configuration is saved on the controller(s) and on the disks
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
CM
Disk
Encryption key (Encrypted)
Encryption key
(plain data)
Master key
Data (Plain data)
1. Decrypts key
Data (Encrypted)
Encryption buffer
CACHE
Data (Encrypted)
2. Encrypts/ decrypts
data
33
Power Saving Eco-mode (1) Reduces power consumption When drives (RAID Groups) are used only a few hours per day
(for example for backup), Eco-mode is an effective way of saving power Drive spin down can be scheduled
• Drives are spun down if idle during the schedule time Drives are spun up automatically when accessed Can be managed with GUI or CLI of ETERNUS DX series
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
AM
12 on
off PM off
12 ・・・
・・・ ETERNUS DX
Data volume 600 GB SAS x 36
RAID 5 (5D+1P), 3 TB
All backup Volume drives are "ON" only for five hours a day Up to 15% power consumption reduction!!
Backup volume 1 TB Nearline SAS x 36
RAID 5 (6D+1P), 6 TB
5
34
Power Saving Eco-mode (2) Eco-mode allows the disks to be spun down for specified
periods and thus reduce the overall power consumption A schedule to spin up and spin down the disks can be set per RAID
Group
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2 35
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Firmware Firmware Version xx and patch Level yy (VxxLyy) Initial release firmware version for DX60 S2 is V20L10-0000 1)
One firmware file for the whole system Up to 3 versions can be held as history on the system Firmware can be updated online via ETERNUS Manager (Web
GUI) Dual Controller
configuration and MultiPath required
1) September 2011
36
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
FRUs and CRUs Field Replaceable Units Controller Enclosure
• Chassis (includes two PSUs) • Controller Modules • Power Supply Units • Operation Panel • Flange cover • Disks - available also as CRUs • SFP (4 Gb)
Drive Enclosure • Chassis (includes two PSUs) • SAS Expander • Power Supply Units • Disks - available also as CRUs • SAS cable (0.75 m)
End customers can order the CRUs through Helpdesk 37
Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2
Manuals and Support Information A document CD-ROM is shipped with the system Installation Guide Server Connection Guides ETERNUS Manager User Guide
Generic ETERNUS DX related information in the Partnernet https://partners.ts.fujitsu.com/COM/PRODUCTS/STORAGE/ONLINE/Pages/default.aspx Service and support related ETERNUS DX information in the
Partnernet https://partners.ts.fujitsu.com/com/service/ps/storage/Pages/default.aspx For Partnernet access a login is required Can be applied for over the above links
38