eternus dx60 s2 - fujitsu · single controller system can be expanded to a dual controller system...

40
0 Copyright Fujitsu Technology Solutions, Release September 2011 ETERNUS DX60 S2 Product Introduction Product Introduction ETERNUS DX60 S2

Upload: truongbao

Post on 16-Dec-2018

246 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

0 Copyright Fujitsu Technology Solutions, Release September 2011

ETERNUS DX60 S2

Product Introduction

Product Introduction ETERNUS DX60 S2

Page 2: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Highlights Low environmental impact Highly scalable & versatile connectivity User friendly management systems Outstanding reliability

1

Page 3: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Overview

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

ETERNUS DX60 ETERNUS DX60 S2

Number of Controllers 1 or 2

Cache Capacity per system 2 GB (1 GB per CM)

CPU 800 MHz 1.2 GHz

Cache Data backup Write back to NAND Flash Memory powered by SCU

Cache Hold Time No Limitation

Host Interfaces

FC (2.5" and 3.5") 4 Gbps

iSCSI (2.5" and 3.5") 1 Gbps

SAS (2.5" and 3.5") 3 Gbps

Drive Types SAS / Nearline SAS (3 Gbps)

RAID Levels 0,1,1+0,5,5+0, 6

Maximum number of HDDs Number of HDD / Enclosure

3.5” 24 (12 in 2U)

2.5” 24 (24 in 2U)

Maximum number of LUNs 512

Maximum number of HBAs 64 (16/port)

RAID Migration Yes

Base Copy Functions SnapOPC+ or QuickOPC

Optional Copy Functions SnapOPC+, OPC, QuickOPC, EC,

Encryption Yes

Eco-mode Yes

Supported OS Windows, Linux, VMware, Unix

2

Page 4: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Optional Modules Flexible response to business expansion 2.5" configuration

• 2.5" Controller Enclosure • Up to 24 2.5" disk drives

• Maximum system capacity 21.6 TB (SAS)

3.5" configuration • 3.5" Controller Enclosure

• Up to 12 3.5" disk drives • Maximum 36 TB (Nearline-SAS)

• 3.5" Drive Enclosure • Up to 12 3.5" disk drives

• Maximum of 24 disks (12 in CE + 12 in DE) • Maximum total system capacity 72 TB (Nearline-SAS)

Single controller system can be expanded to a dual controller system

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2 3

Page 5: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Disk Drives (1) Support for high performance disk drives (15,000 rpm) and

large capacity disk drives suitable for backup 3.5"

• SAS disk drives (15,000 rpm, 3 Gbit/s) • 600 GB / 450 GB / 300 GB

• Nearline SAS drives (7200 rpm, 3 Gbit/s) • 3 TB / 2 TB / 1 TB

2.5" • SAS disk drives (10,000 rpm, 3 Gbit/s)

• 900 GB / 600 GB / 450 GB / 300 GB SSD not supported

Disk LED

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

DISK READY Green: Normal status Blinking green: Normal operation

DISK FAULT Orange: Error status Blinking orange: Disk locator

DISK READY/FAULT Green: Normal status Blinking green: Normal operation Orange: Error status Blinking orange: Disk locator

4

Page 6: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Disk Drives (2) Possible to mix different types of disk drives Possible to choose the right kind of disk for every usage

• Nearline SAS for capacity • SAS for performance and reliability

DX60 S2 disk drives are physically not compatible with the other S2 models New disk capacities introduced with the DX60 S2 are not

compatible with the earlier DX Entry models

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

ETERNUS DX60 S2 SAS

Nearline SAS

5

Page 7: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

RAID Levels RAID 1+0 is recommended for

business databases that are updated frequently Select RAID 1+0 for systems

that require high reliability and high performance

RAID 5 (RAID 5+0 if enough disks are available) or RAID 6 is recommended for data that requires less random performance or for systems where there is a high level of reading Global and dedicated Hot Spares are available, all disks can

be used except the system disks

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

RAID level Number of disks 1 2

1 + 0 4-24 (even number) 5 3-16 6 5-16

5 + 0 6-24 (even number)

6

Page 8: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

ETERNUS DX Advanced Copy Functions (1) The Advanced Copy functions allow the DX to carry out high-

speed data copying operations on its own, without using any server resources Data Copies and Snapshots via GUI or CLI commands Data backup in a live data environment using the Microsoft Windows

Server Volume Shadow Copy Service (VSS) function with VSS-compatible backup software

Software solutions for quick data backup, restoration and replication ETERNUS SF Express

• Basic functionality comes free of charge ETERNUS SF AdvancedCopy Manager

• Requires a separate license

With both SF Express v14.2 and ACM v14.2 patch v14.2A needs to be installed for the DX60 S2

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2 7

Page 9: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

ETERNUS DX Advanced Copy Functions (2) Free trial use before purchasing software license Able to use eight sessions

of Snapshot (SnapOPC+) for free

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

>xxxxxxx

Able to use Snapshots for free (up to eight sessions) ETERNUS DX60 S2

Standard With Local Copy license 1)

No. of sessions 8 512

Operation I/F GUI/CLI VSS Express GUI/CLI VSS Express ACM

Supp

orte

d fu

nctio

n

SnapOPC+ x x x x x x x

QuickOPC - x - - x x x

OPC - - - - - x x

EC - - - - - x x

Feature Copies without optional software

Meets various requirements using ISV backup software

Simplifies initial settings of copy

Copies without optional software

Meets various requirement in Windows environment using ISV backup software

Enables easy device management and backup

Supports various OS and ISV applications, and able to use all Advanced Copy functions

Express = ETERNUS SF Express ACM = ETERNUS SF Advanced Copy Manager VSS = Microsoft Windows Server Volume Shadow Copy Service No. of sessions = Max. number of copies to be executed at a time 1) Need to purchase the copy license separately

Step up Step up

8

Page 10: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Identification The Serial Number is located on top left hand side of the shelf With both Controller Enclosure and Drive Enclosure the first two digits of

the serial number are 45... Two-digit Check Code can be found on a separate sticker by the

identification label • Default password for the

user account "f.ce" is "<check code><serial-no.>"

9

Page 11: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

System Modules

Controller Enclosure for 2.5" Disks Controller Enclosure for 3.5" Disks Controller Modules Drive Enclosure

Product Introduction ETERNUS DX60 S2 Copyright Fujitsu Technology Solutions, Release September 2011 10

Page 12: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Controller Enclosure for 2.5" Disks Front view with bezel

Front view with bezel removed

Disk slot numbering

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Sys

tem

dis

k S

yste

m d

isk

Operation Panel

11

Page 13: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Controller Enclosure for 3.5" Disks Front view with bezel

Front view with bezel removed

Disk slot numbering

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

System disk System disk

12

Page 14: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Controller Enclosure Operation Panel Controller Enclosure for 2.5" disks

Controller Enclosure for 3.5" disks

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

AUTO POWER ON: Connected DE is always powered on OFF: Default setting

POWER Green: DC power supply OK READY Green: System is ready for use FAULT Orange: Error status Blinking orange: Preventive maintenance required IDENTIFY Blinking blue: Activated from Web GUI CACHE Green: Data in cache Blinking green: Cached data saved to NAND Flash

MODE SELECT ON: Connected DE is powered on with power switch OFF: Do not use IP RESET - Push once to toggle the Master CM - Push twice within two seconds to reset the LAN port settings

With flange cover Without flange cover

Power switch - Push four seconds to switch the system off

13

Page 15: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Controller Enclosure Rear View

Power inlet

STATUS Green: Mains power supply OK, system on Blinking green: Mains power supply OK, system off Orange: PSU or fan in error status

PSU#1

CM#1

PSU#0

CM#0

Power cable strain relief

Module eject lever

14

Page 16: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Controller Module Fibre Channel SCU STATUS Green: Normal status Blinking green: SCU is charging

IDENTIFY Blinking blue: Activated from Web GUI

DI OUT Green: Link to DE established

DI OUT Port RMT Port Not used

MNT Port

FC LINKUP / FAULT Green: Link to Host established Orange: Error status

FC Port 1

Unit Ready / Fault Green: Normal status Orange: Initial setup running or Error status

MASTER Green: This CM is set as Master

ACT LED Green: Sending or receiving data

LINK LED Green: Link established

Not used

FC Port 0 FC LINKUP / FAULT Green: Link to Host established Orange: Error status

15

Page 17: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Controller Module iSCSI

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

SCU STATUS Green: Normal status Blinking green: SCU is charging

IDENTIFY Blinking blue: Activated from Web GUI

DI OUT Green: Link to Drive Enclosure established

DI OUT Port RMT Port Not used

MNT Port

iSCSI Port 0 iSCSI Port 1

Unit Ready / Fault Green: Normal status Orange: Initial setup running or Error status

MASTER Green: This CM is set as Master

ACT LED Green: Sending or receiving data

LINK LED Green: Link established

Not used

ACT LED Green: Sending or receiving data

LINK LED Green: Link establishe

16

Page 18: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Controller Module SAS

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

SCU STATUS Green: Normal status Blinking green: SCU is charging

IDENTIFY Blinking blue: Activated from Web GUI

DI OUT Green: Link to Drive Enclosure established

DI OUT Port RMT Port Not used

MNT Port Unit Ready / Fault Green: Normal status Orange: Initial setup running or Error status

MASTER Green: This CM is set as Master

ACT LED Green: Sending or receiving data

LINK LED Green: Link established

Not used

SAS (HOST) LINKUP / FAULT Green: Link to Host established Orange: Error status

SAS Port 1

SAS Port 0 SAS (HOST) LINKUP / FAULT Green: Link to Host established Orange: Error status

17

Page 19: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Drive Enclosure for 3.5" Disks Front view with bezel

Front view with bezel removed

Disk slot numbering

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2 18

Page 20: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Drive Enclosure Operation Panel

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

AUTO POWER ON: Do not use OFF: Default setting

MODE SELECT ON: DE is powered on with power switch OFF: Do not use

Not used

POWER Green: DC power supply OK READY System is ready for use FAULT Orange: Error status Blinking orange: Preventive maintenance required IDENTIFY Blinking blue: Activated from Web GUI

With flange cover Without flange cover

Not used

19

Page 21: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Drive Enclosure Rear View

PSU#1

EXP#1

PSU#0

EXP#0

DI IN Port Unit Ready / Fault Green: Normal status Orange: Initial setup running or Error status

DI (IN) LINKUP / FAULT Green: Link to CE established Orange: Error status

IDENTIFY Blinking blue: Activated from Web GUI

Not used

20

Page 22: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Product Features

Battery Free Cache Protection 8 Gbit Fiber Channel Interface High Availability and Advanced Data Protection Dynamic LUN Migration, LUN Concatenation and Logical

Device Expansion Data Encryption Eco-mode

Product Introduction ETERNUS DX60 S2 Copyright Fujitsu Technology Solutions, Release September 2011 21

Page 23: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Block Diagram Controller Enclosure

Drive Enclosure

BP PSU PSU

PSU PSU BP

SCU

LSI

RoC Cache

Expander

Nonvolatile memory

Panel

Monitor PLD

CM#1

RoC

Expander

Cache LSI

Nonvolatile memory

SCU SCU

Monitor PLD

CM#0

EXP#0 EXP#1 Panel Monitor PLD

Monitor PLD Expander Expander

To Drive Enclosure

(SAS interface)

RAID-on-Chip (RAID Controller)

SAS Expander

Controller Interconnect

(PCI Express x4)

Host Interface (Fiber Channel, iSCSI or SAS)

System Capacitor Unit

Controller Module

22

Page 24: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Battery Free Cache Protection (1) Reduced maintenance window SCU* is maintenance free for 5 years

• Battery replacement was required every three years in the previous models

Avoid data loss during extended power outages Migrating cache data to a nonvolatile memory

ensures unlimited data retention time • Previously battery back up supported cache

data for approximately 96 hours

Cached write performance recovered almost immediately after power restoration SCU recharge time about three minutes

• Exact battery recovery time depends on how long the power has been unavailable

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

• SCU is a unit with electric double layer capacitor. Electric double layer capacitor has the advantages of being very resistant to degrading and by providing a short recharge time compared to traditional batteries.

Data Data

Migrate cache data to a nonvolatile memory at high speed through a

dedicated line

SCU

SCU* supplies power when power

fails

Nonvolatile memory

Memory LSI RoC Memory

23

Page 25: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Battery Free Cache Protection (2) Technology comparison

Data Data

Migrate cache data to a nonvolatile memory at high speed through a

dedicated line

RoC Memory

BBU CM#0

Data

Power is supplied from BBU* to memory when power fails.

Cache data can be kept as long as the battery has power

Technology based on a BBU

BBU = Battery Backup Unit

Technology based on a SCU

SCU SCU supplies power

when power fails

Nonvolatile memory

Memory LSI RoC Memory

24

Page 26: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

High Availability Duplicated components Basic configuration contains

always two Power Supplies The Controller Module can be

optionally duplicated

Components are hot swappable Hot expansion of disk drives Hot firmware upgrade

supported

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

PSU: Power Supply Unit , SCU: System Capacitor Unit, RoC: RAID-on-Chip

PSU PSU

PSU PSU

BP

BP

SCU

LSI RoC Cache

Expander

CM#0

NAND Flash

Monitor PLD

SCU

Base System

Expansion Shelf

CM#1

RoC

Expander

Cache LSI NAND Flash

SCU

Monitor PLD

Expander Expander EXP#0 EXP#1 Panel Monitor

PLD Monitor

PLD

Panel

25

Page 27: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Data Protection by Data Block Guard 8-byte check code is added to every 512-byte data to

control data integrity on the disk and in the cache Guarantees consistency of all stored data

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

WRITE READ

Apply Check Code

(2) (3)

(4)

DISK

User Data

CC: Check Code

A0 A1 A2

A0 A1 A2 CC CC CC

User Data A0 A1 A2

A0 A1 A2 CC CC CC

A0 A1 A2 CC CC CC

Controller Module

Written Data

ETERNUS DX

Write Check Code

Verify Check Code

(1)

Cache ECC Protected

Verify & delete Check Code (4)

(2)

(1)

(3)

26

Page 28: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Control of a Failed Disk Two different modes are supported Rebuild

• ETERNUS DX rebuilds the data of a failed drive from the remaining drives and writes it to a Hot Spare • When no Hot Spare is available

ETERNUS DX rebuilds the data after the defective drive is replaced

• Redundancy of the RAID Group is recovered after rebuild is completed

Copy Back • After redundancy of the RAID

Group is re-established, data is copied back from the Hot Spare to the replaced drive

Copyright Fujitsu, Release August 2011 Common Features ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2

HS

Disk replacement

Failed

Failed

Without redundancy

Recover redundancy

New

Without redundancy

Recover redundancy

Failed Disk replacement

New

Rebuild

Copy Back

Rebuild Failed

HS

27

Page 29: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Global and Dedicated Hot Spare Dedicated Hot Spare (DHS) disk Has to be assigned to a specific

RAID Group When a disk of a RAID Group with

a Dedicated HS fails, then this Dedicated HS is selected and used to rebuild the RAID Group

Global HS (GHS) Used by all RAID Groups When a disk in any RAID Group fails

and there is no Dedicated HS available, a Global HS is used to rebuild the RAID Group

Copyright Fujitsu, Release August 2011 Common Features ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2

GHS

DHS

DHS

: Global Hot Spare

: Dedicated Hot Spare for RAID Group D

: Dedicated Hot Spare for RAID Group E

ETERNUS DX S2

RAID Group D

RAID Group E DHS

DHS

Failed

RAID Group C

RAID Group B

RAID Group A GHS

28

Page 30: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Dynamic LUN Expansion The ETERNUS DX Series is able to expand the capacity of

LUN (Logical Unit Number) without stopping the operation

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Expand Logical device expansion

LUN Concatenation

LUN0 New

added drive Current

RAID Group RAID 5 (4+1)

LUN0 Unused area

Expand RAID Group by "Logical Device Expansion"

RAID Group now RAID 5 (5+1)

LUN0

Expand LUN0 capacity by "LUN concatenation"

RAID Group RAID 5 (5+1)

29

Page 31: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Logical Device Expansion Expand capacity (free space) of a RAID Group by adding

unused disk drives RAID level can be changed

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Expands

Existing RAID Group RAID 5 (3+1)

Unused disks not assigned to any RAID Group

Same RAID Group RAID 5 (5+1)

30

Page 32: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

LUN Concatenation LUN capacity can be expanded by using LUN concatenation Consolidates unused areas in the same or across multiple

RAID Groups for efficient use of drives NOTE: After LUN Concatenation it may be necessary to adapt

the Operating System and/or application to recognize the increased LUN size Maximum LUN capacity is 32 TB Minimum LUN capacity is 1 GB Maximum number of LUNs that can be concatenated is 16 Able to mix different RAID levels

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

RAID 5 450 GB x4

LUN1 600 GB

RAID 5 450 GB x4

Unused area 1.2 TB

RAID 5 450 GB x4

LUN1 600 GB

RAID 5 450 GB x4

LUN0 1.2 TB Concatenate LUN2 600 GB

RAID Group 1 RAID Group 2

RAID-Grp1

RAID Group 2

LUN0 1.2 TB LUN2 with 1.8 TB

RAID Group 1

31

Page 33: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

RAID Migration Enables data to be moved between different RAID Groups

without interrupting operation Migrate existing LUNs from a RAID Group to a different one Migration between different RAID levels RAID migration to expand LUN capacity Migration is transparent from server point of view

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Migrate data to large capacity drives

Migrate data to a high reliable RAID level

LUN 0

RAID 5 300 GB

Unused 600 GB

RAID Group 1

RAID Group 2

Unused 300 GB

LUN 0 RAID 5 600 GB

RAID Group 1

RAID Group 2

RAID 5 600 GB

Unused 600 GB

LUN 0

RAID Group 1

RAID Group 2

Unused 600 GB

RAID 1+0 600 GB

LUN 0 Mirroring

LUN 0

RAID Group 1

RAID Group 2

32

Page 34: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Data Encryption Fujitsu's unique encryption algorithm can be enabled via

ETERNUS Web GUI Encrypts user data in units

of LUN Both encrypted and unencrypted

data can exist in the same RAID Group

Possible to encrypt an existing unencrypted Volume For redundancy, the Data

Encryption configuration is saved on the controller(s) and on the disks

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

CM

Disk

Encryption key (Encrypted)

Encryption key

(plain data)

Master key

Data (Plain data)

1. Decrypts key

Data (Encrypted)

Encryption buffer

CACHE

Data (Encrypted)

2. Encrypts/ decrypts

data

33

Page 35: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Power Saving Eco-mode (1) Reduces power consumption When drives (RAID Groups) are used only a few hours per day

(for example for backup), Eco-mode is an effective way of saving power Drive spin down can be scheduled

• Drives are spun down if idle during the schedule time Drives are spun up automatically when accessed Can be managed with GUI or CLI of ETERNUS DX series

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

AM

12 on

off PM off

12 ・・・

・・・ ETERNUS DX

Data volume 600 GB SAS x 36

RAID 5 (5D+1P), 3 TB

All backup Volume drives are "ON" only for five hours a day Up to 15% power consumption reduction!!

Backup volume 1 TB Nearline SAS x 36

RAID 5 (6D+1P), 6 TB

5

34

Page 36: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Power Saving Eco-mode (2) Eco-mode allows the disks to be spun down for specified

periods and thus reduce the overall power consumption A schedule to spin up and spin down the disks can be set per RAID

Group

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2 35

Page 37: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Firmware Firmware Version xx and patch Level yy (VxxLyy) Initial release firmware version for DX60 S2 is V20L10-0000 1)

One firmware file for the whole system Up to 3 versions can be held as history on the system Firmware can be updated online via ETERNUS Manager (Web

GUI) Dual Controller

configuration and MultiPath required

1) September 2011

36

Page 38: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

FRUs and CRUs Field Replaceable Units Controller Enclosure

• Chassis (includes two PSUs) • Controller Modules • Power Supply Units • Operation Panel • Flange cover • Disks - available also as CRUs • SFP (4 Gb)

Drive Enclosure • Chassis (includes two PSUs) • SAS Expander • Power Supply Units • Disks - available also as CRUs • SAS cable (0.75 m)

End customers can order the CRUs through Helpdesk 37

Page 39: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3

Copyright Fujitsu Technology Solutions, Release September 2011 Product Introduction ETERNUS DX60 S2

Manuals and Support Information A document CD-ROM is shipped with the system Installation Guide Server Connection Guides ETERNUS Manager User Guide

Generic ETERNUS DX related information in the Partnernet https://partners.ts.fujitsu.com/COM/PRODUCTS/STORAGE/ONLINE/Pages/default.aspx Service and support related ETERNUS DX information in the

Partnernet https://partners.ts.fujitsu.com/com/service/ps/storage/Pages/default.aspx For Partnernet access a login is required Can be applied for over the above links

38

Page 40: ETERNUS DX60 S2 - Fujitsu · Single controller system can be expanded to a dual controller system Product Introduction ETERNUS DX60 S2 3