Page 1: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

ETERNUS DX80 S2 and DX90 S2

Hardware Installation

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

Page 2: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Package Contents Rack Mounting Power Cabling Backend Cabling QSFP Power On Procedure Power Off Procedures Operator Panel - Function Button

Hardware Installation ETERNUS DX80 S2 and DX90 S2 Copyright Fujitsu Technology Solutions, Release August 2011

Content

1

Page 3: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Package Contents (1)Controller Enclosure Kit Installation poster Documentation CD Rack mount kit Controller Enclosure

• Single Controller Module• Dual Controller Module

Left and right Flange Cover Push pin tool 2 x power cords Safety Manual

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 2

Page 4: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Package Contents (2)Drive Enclosure Kit Installation poster Rack mount kit Drive Enclosure 2 x power cords 1 x QSFP (SAS) cable

• Single IOM configuration 2 x QSFP (SAS) cables

• Dual IOM configuration Safety Manual

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 3

Page 5: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Rack Mounting (1)For FTS (CEMEA &I) onlyRack-mount kit

Rack mount installation overview

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 4

Page 6: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

M5 Centeringscrews (10 mm)

2U Bracket

Rack Mounting (2)Attach the 2U Bracket to the right rear

rack pillar The M5 centering screws should be

inserted in the 1st and 6th holesabove the base line of theEnclosures

Insert the pins of the left handside slide rail in the 1st and3rd hole Start counting from the bottom

of the 2U Bracket

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

Base line of theController Enclosure

5

Page 7: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

M5 Cage nut

Rack Mounting (3)Push the M5 cage nut into the

2nd hole of the front rack pillar Above the base line of the Enclosures

At the left hand side fix the sliderail to the front pillar with The M5 centering screws The M5 pan head screws

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

M5 Centeringscrew (10 mm)

M5 Pan headscrew (10 mm)

Base line of theController Enclosure

6

Page 8: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Rack Mounting (4)For the left hand side rail Insert the pins in the holes of the rear pillar Fix the other side of the slide rail to the front pillar

• Repeat the same procedure as done before with the left hand side slide rail

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

Base line of theController Enclosure

M5 Cage nut

Base line of theController Enclosure

M5 Pan headscrew (10 mm)

M5 Centeringscrew (10 mm)

7

Page 9: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Rack Mounting (5)Front view of the rack installation

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 8

Page 10: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Rack Mounting (6)Fit the Controller Enclosure and/or Drive Enclosure to the rackFor better stability, a rack has to be filled by starting from the

bottom

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 9

Page 11: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Power Cabling

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

For FTS (CEMEA&I) only Connect the rack PDUs

(Power Distribution Units) to independent AC power phases

Make sure that the AC power switches on each Enclosure are turned off beforeconnecting their power cables

Connect each Power Supply of an Enclosure to different Power Distribution Units

PSU#0 inlet PSU#1 inlet

PSU#0inlet

PSU#1inlet

Left Rack PDU

RightRack PDU

Always follow the localpower cabling regulations!

10

Page 12: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Backend Cabling QSFP (1)SAS Port at the CM or IOM6 (SAS Expander) Connect SAS (OUT) ports and SAS (IN) ports by daisy-chain Start in ascending order from the Controller Enclosure

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

Drive Enclosure# 02

Drive Enclosure #01

Controller Enclosure

11

Page 13: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Backend Cabling QSFP (2)Follow the SAS port labels at the Enclosures This will point to the correct cabling

This sign means "IN" and this sign means "OUT" Connect the cables according the labels showing direction ( and ) SAS ports of the Controller Enclosure always have the type "OUT"

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

Connect withthe port where

is indicated

Connect withthe port where

is indicated

DE

CE

OUT IN

Cable symbol OUT

12

Page 14: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Backend Cabling QSFP (3)QSFP connection between racks To connect QSFP cable between two racks an expansion cable of 3 or 6

meters is used

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 13

Page 15: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Single / Dual Controller UpdateA single CM configuration is allowed to be upgraded to a

dual CM configuration in the field Also the Drive Enclosure need to be upgraded

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

CECM #0

DEIOM6

DEIOM6

CE

DEIOM6

DEIOM6

IOM6

IOM6

Single CM Dual CM

CA CA

CM#0

CA CA

CM#1

CACA

1 CM to 2 CM upgrade parts

CA: Channel AdapterIOM: IO moduleDE: Device Enclosure

14

Page 16: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Power On Procedure (1)The ETERNUS DX S2 systems can be Powered On directly

from the Controller Enclosure Push the Power Switch

• The "Power" LED of the CE switches on• The power on sequence takes about 2 minutes• If everything is OK, the green Ready LED in

the CE and the green Power LED in the DEswitch on

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

Power OFault OActive O

Power OReady OFault OMaint/ID OCache O

15

Page 17: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Power On Procedure (2)Controller Enclosure LEDs

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

POWER LED Constant green when the power is turned onREADY LED Constant green when device is available

for useFAULT LED Constant amber when a failure is detected

in the ETERNUS DX system Blinks in amber when a component which

requires preventive maintenance is detected MAINT/ID LED Constant green when the system has its

status set to Maintenance Blinks green Status of all components needs to be

verified with the GUI or CLI Locate functionality enabled by the GUI

or CLICACHE LED Constant green when data exists in cache memory Blinks in green when cached data is saved to the flash memory

16

Page 18: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Power On Procedure (3)Drive Enclosure LEDs

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

LINE LED AC power is supplied to the Drive EnclosureFAULT LED Constant amber when a failure is detected

in the Drive EnclosurePOWER LED The Drive Enclosure is operating normallyDE-ID (7-segment) Shows a 2-digit Drive Enclosure ID Is assigned automatically by the SAS

backend cabling

2.5" Drive Ecnlosure

3.5" Drive Ecnlosure

17

Page 19: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Power Off ProcedureVerify with the customer that all server I/O is stopped Also confirm that the "CACHE" LED in the Operator Panel is off

Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will shutdown all Enclosures gracefully

In case of moving ETERNUS to a new location, you naturally have to also disconnect the AC power cordsfrom the PDUs after the system is powered off

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

Make sure the CACHE LEDof the Controller Enclosureis off

18

Page 20: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Operator Panel - Function Button (1)Remove the plastic Flange Cover to get access to

the Function ButtonThe Function Button is located

next to the Power Switch

Use the pin tool to operate

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2

Function Button

Power Button

2.5" Controller Enclosure 3.5" Controller Enclosure

19

Page 21: ETERNUS DX80 S2 and DX90 S2 - FiOLA - Login Customer · 2011-09-22 · Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will

Operator Panel - Function Button(2)The operation can be performed by carrying out the following

steps To toggle the system status between "Maintenance" and "Normal"

• Keep the Function Button pushed for three seconds• The MAINT/ID LED lights green when the system is in Maintenance mode• The MAINT/ID LED is off when the system is in Normal mode

Switch the functionality of Master CM to the other Controller Module• Push down the Function Button twice within three seconds• The Master LED lights green to indicate the Master CM

Reset the LAN ports of the CM to the default values• Push down the Function Button three times within three seconds• The MAINT/ID LED blinks green for a few seconds

Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 20