ETERNUS DX80 S2 and DX90 S2
Hardware Installation
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
Package Contents Rack Mounting Power Cabling Backend Cabling QSFP Power On Procedure Power Off Procedures Operator Panel - Function Button
Hardware Installation ETERNUS DX80 S2 and DX90 S2 Copyright Fujitsu Technology Solutions, Release August 2011
Content
1
Package Contents (1)Controller Enclosure Kit Installation poster Documentation CD Rack mount kit Controller Enclosure
• Single Controller Module• Dual Controller Module
Left and right Flange Cover Push pin tool 2 x power cords Safety Manual
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 2
Package Contents (2)Drive Enclosure Kit Installation poster Rack mount kit Drive Enclosure 2 x power cords 1 x QSFP (SAS) cable
• Single IOM configuration 2 x QSFP (SAS) cables
• Dual IOM configuration Safety Manual
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 3
Rack Mounting (1)For FTS (CEMEA &I) onlyRack-mount kit
Rack mount installation overview
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 4
M5 Centeringscrews (10 mm)
2U Bracket
Rack Mounting (2)Attach the 2U Bracket to the right rear
rack pillar The M5 centering screws should be
inserted in the 1st and 6th holesabove the base line of theEnclosures
Insert the pins of the left handside slide rail in the 1st and3rd hole Start counting from the bottom
of the 2U Bracket
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
Base line of theController Enclosure
5
M5 Cage nut
Rack Mounting (3)Push the M5 cage nut into the
2nd hole of the front rack pillar Above the base line of the Enclosures
At the left hand side fix the sliderail to the front pillar with The M5 centering screws The M5 pan head screws
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
M5 Centeringscrew (10 mm)
M5 Pan headscrew (10 mm)
Base line of theController Enclosure
6
Rack Mounting (4)For the left hand side rail Insert the pins in the holes of the rear pillar Fix the other side of the slide rail to the front pillar
• Repeat the same procedure as done before with the left hand side slide rail
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
Base line of theController Enclosure
M5 Cage nut
Base line of theController Enclosure
M5 Pan headscrew (10 mm)
M5 Centeringscrew (10 mm)
7
Rack Mounting (5)Front view of the rack installation
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 8
Rack Mounting (6)Fit the Controller Enclosure and/or Drive Enclosure to the rackFor better stability, a rack has to be filled by starting from the
bottom
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 9
Power Cabling
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
For FTS (CEMEA&I) only Connect the rack PDUs
(Power Distribution Units) to independent AC power phases
Make sure that the AC power switches on each Enclosure are turned off beforeconnecting their power cables
Connect each Power Supply of an Enclosure to different Power Distribution Units
PSU#0 inlet PSU#1 inlet
PSU#0inlet
PSU#1inlet
Left Rack PDU
RightRack PDU
Always follow the localpower cabling regulations!
10
Backend Cabling QSFP (1)SAS Port at the CM or IOM6 (SAS Expander) Connect SAS (OUT) ports and SAS (IN) ports by daisy-chain Start in ascending order from the Controller Enclosure
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
Drive Enclosure# 02
Drive Enclosure #01
Controller Enclosure
11
Backend Cabling QSFP (2)Follow the SAS port labels at the Enclosures This will point to the correct cabling
This sign means "IN" and this sign means "OUT" Connect the cables according the labels showing direction ( and ) SAS ports of the Controller Enclosure always have the type "OUT"
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
Connect withthe port where
is indicated
Connect withthe port where
is indicated
DE
CE
OUT IN
Cable symbol OUT
12
Backend Cabling QSFP (3)QSFP connection between racks To connect QSFP cable between two racks an expansion cable of 3 or 6
meters is used
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 13
Single / Dual Controller UpdateA single CM configuration is allowed to be upgraded to a
dual CM configuration in the field Also the Drive Enclosure need to be upgraded
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
CECM #0
DEIOM6
DEIOM6
CE
DEIOM6
DEIOM6
IOM6
IOM6
Single CM Dual CM
CA CA
CM#0
CA CA
CM#1
CACA
1 CM to 2 CM upgrade parts
CA: Channel AdapterIOM: IO moduleDE: Device Enclosure
14
Power On Procedure (1)The ETERNUS DX S2 systems can be Powered On directly
from the Controller Enclosure Push the Power Switch
• The "Power" LED of the CE switches on• The power on sequence takes about 2 minutes• If everything is OK, the green Ready LED in
the CE and the green Power LED in the DEswitch on
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
Power OFault OActive O
Power OReady OFault OMaint/ID OCache O
15
Power On Procedure (2)Controller Enclosure LEDs
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
POWER LED Constant green when the power is turned onREADY LED Constant green when device is available
for useFAULT LED Constant amber when a failure is detected
in the ETERNUS DX system Blinks in amber when a component which
requires preventive maintenance is detected MAINT/ID LED Constant green when the system has its
status set to Maintenance Blinks green Status of all components needs to be
verified with the GUI or CLI Locate functionality enabled by the GUI
or CLICACHE LED Constant green when data exists in cache memory Blinks in green when cached data is saved to the flash memory
16
Power On Procedure (3)Drive Enclosure LEDs
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
LINE LED AC power is supplied to the Drive EnclosureFAULT LED Constant amber when a failure is detected
in the Drive EnclosurePOWER LED The Drive Enclosure is operating normallyDE-ID (7-segment) Shows a 2-digit Drive Enclosure ID Is assigned automatically by the SAS
backend cabling
2.5" Drive Ecnlosure
3.5" Drive Ecnlosure
17
Power Off ProcedureVerify with the customer that all server I/O is stopped Also confirm that the "CACHE" LED in the Operator Panel is off
Hold down the "Power Switch" of the Controller Enclosure for approximately 5 seconds The ETERNUS DX system will shutdown all Enclosures gracefully
In case of moving ETERNUS to a new location, you naturally have to also disconnect the AC power cordsfrom the PDUs after the system is powered off
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
Make sure the CACHE LEDof the Controller Enclosureis off
18
Operator Panel - Function Button (1)Remove the plastic Flange Cover to get access to
the Function ButtonThe Function Button is located
next to the Power Switch
Use the pin tool to operate
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2
Function Button
Power Button
2.5" Controller Enclosure 3.5" Controller Enclosure
19
Operator Panel - Function Button(2)The operation can be performed by carrying out the following
steps To toggle the system status between "Maintenance" and "Normal"
• Keep the Function Button pushed for three seconds• The MAINT/ID LED lights green when the system is in Maintenance mode• The MAINT/ID LED is off when the system is in Normal mode
Switch the functionality of Master CM to the other Controller Module• Push down the Function Button twice within three seconds• The Master LED lights green to indicate the Master CM
Reset the LAN ports of the CM to the default values• Push down the Function Button three times within three seconds• The MAINT/ID LED blinks green for a few seconds
Copyright Fujitsu Technology Solutions, Release August 2011Hardware Installation ETERNUS DX80 S2 and DX90 S2 20