0 Copyright Fujitsu Technology Solutions, Release September 2011
ETERNUS DX60 S2
Hardware and Software Installation
Hardware and Software Installation ETERNUS DX60 S2
Hardware Installation
Package Contents Rack Mounting Power Cabling Backend Cabling Power On and Power Off Procedures
Hardware and Software Installation ETERNUS DX60 S2 Copyright Fujitsu Technology Solutions, Release September 2011 1
Package Contents (1) Controller Enclosure Kit Installation poster Documentation CD Rack mount kit Controller Enclosure Front bezel 2 X power cord Safety Manual
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 2
Package Contents (1) Drive Enclosure Kit Installation poster Rack mount kit Drive Enclosure Front bezel 2 X power cords 2 X SAS cables Safety Manual
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 3
Rack Mounting (1) Rack mount kit
Rack mount installation overview
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 4
Rack Mounting (1) Attach the 2U Bracket to the
left rear rack pillar Insert the pins of the left hand
side slide rail in the 1st and 3rd hole counting from the bottom of the 2U Bracket
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
M5 Centering screws (10 mm)
2U Bracket
Base line of the Controller Enclosure
5
Rack Mounting (2) Push the M5 cage nut into the
2nd hole of the front rack pillar above the base line of the Controller Enclosure Secure the left hand side slide
rail to the front pillar using the M5 centering screw and M5 pan head screws
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
M5 Centering screw (10 mm)
M5 Pan head screw (10 mm)
M5 Cage nut
Base line of the Controller Enclosure
6
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Rack Mounting (3) For the right hand side rail, insert the pins in the holes of the
rear pillar, and secure the other side of the slide rail to the front pillar in the same way as with the left slide rail
Base line of the Controller Enclosure
M5 Cage nut
Base line of the Controller Enclosure
M5 Pan head screw (10 mm)
M5 Centering screw (10 mm)
7
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Rack Mounting (4) Front view of rack installation
8
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Rack Mounting (5) Fit the Controller Enclosure and/or Drive Enclosure to the rack For better stability, a rack is to be filled starting from the bottom
9
Power Cabling Connect the rack PDUs (Power Distribution Units) to
independent AC power phases Make sure that the AC
power switches on each Enclosure are turned off before connecting their power cables
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Always follow the local power cabling regulations!
10
Backend Cabling (2) The Controller Enclosure and Drive Enclosures are connected
using proprietary SAS cabling The IN and OUT ports and connectors are coded with symbols and are
mechanically coded to prevent incorrect cabling • SAS (IN) port connector
• Plug for SAS (IN) port
• SAS (OUT) port connector
• Plug for SAS (OUT) port
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 11
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Backend Cabling (1) Connect SAS (OUT) ports of the Controller Enclosure with the
SAS (IN) ports of the Drive Enclosure
1 3
2 4
12
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Power On Procedure Power on ETERNUS from Controller Enclosure Push the Power Switch If everything is OK, the READY LED will go green in about three minutes
LEDs
POWER • Green when the power is turned on READY • Green when the system is available for use FAULT • Steady orange when a malfunctioning system
component has been detected • Blinking orange when a preventive replacement of
a system component is required IDENTIFY • Blinking blue when turned on from the
management software CACHE • Steady green when the cache is in use • Blinking green when a power failure has occurred
and the cache data has been stored in the CompactFlash memory
13
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Power Off Procedure Power off the ETERNUS by pressing the Power switch of the
Controller Enclosure for 4 seconds You can power off also using the ETERNUS Web GUI
• Select menu [Utilities] [Shutdown/Restart System] The power supply of the device will shut down in 30 seconds
• If a reboot is chosen, the device will be rebooted after shutdown
Before shutting the system down Ask customer to confirm that all
Server I/O is stopped Check that the CACHE LED on
the Operation Panel is off
Make sure the CACHE LED of the Controller Enclosure is off
14
Software Setup
Initial Configuration Initial Configuration Web GUI Initial Configuration for Expansion Drive Enclosure ETERNUS SF Express
Hardware and Software Installation ETERNUS DX60 S2 Copyright Fujitsu Technology Solutions, Release September 2011 15
Initial Configuration (1) Basic connection guidelines and parameters for a connection
between the management computer and ETERNUS DX IP-address/Subnet mask ETERNUS MNT Port
• Default 192.168.1.1 / 255.255.255.0 Set a fixed IP address for the computer to be connected to ETERNUS
• Needs to within the same IP address subnet with the ETERNUS MNT Port (for example 192.168.1.2)
Connect the LAN port of the computer to the ETERNUS MNT Port • Direct connection with normal or crossed cable
Web browser • Internet Explorer 6.0, 7.0 or 8.0 • Mozilla Firefox 3.0.x, 3.5.x and 3.6.x
Web browser settings • Do not use a proxy server or cache (Temporary Internet Files) • Enable Java Scripting, Style Sheets and Cookies
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 16
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Initial Configuration (2) ETERNUS has one MNT port on each CM, but only the port
with the green Master LED on is enabled The LAN cable must go to the MNT port with the Master LED on
MNT Port CM #0
Master LED CM #0
MNT Port CM #1
Master LED CM #1
17
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Initial Configuration Web GUI (1) To start the installation procedure, logon to ETERNUS DX60
S2 Web GUI using one of the default User Accounts User name: root, Password: root User name: f.ce, Password: <Check Code><System Serial Number>
18
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Initial Configuration Web GUI (2) Opening screen after logon to ETERNUS DX60 S2 Web GUI
Initial configuration steps
General status of the system
19
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Initial Configuration Web GUI (3) General status of the system
Indicator Color Description Green Each component is in normal status Orange Component is under maintenance Yellow Preventive maintenance is required for some components
Yellow Pinned data is detected Administrator User and General User can not see this status
Red This symbol is displayed in the following conditions Component failure is detected Loop Down is detected
Red
This symbol is displayed in the following conditions Abnormal status is detected at power-on Abnormal status is detected at power-off, the device has not
started up normally Failed to restore the operating environment at power-on The device is abnormal
20
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Initial Configuration Web GUI (4) Status of each component
Indicator Color Description
Green The component is in normal status
Blue Some components are installed but unused. (For example, A disk which is not assigned to a RAID group or as a hot spare.)
Orange The component is under maintenance
Yellow Preventive maintenance is required for a component
Red A component failure is detected
21
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Initial Configuration Web GUI (5) Set Date and Time
22
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Initial Configuration Web GUI (6) Set Machine Name (optional)
23
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Initial Configuration Web GUI (7) Change the password if needed (need customer approval)
24
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Initial Configuration Web GUI (8) Set Network Environment (if needed)
25
Configure Expansion Drive Enclosure (1) Choose tab "Maintenance" Select "Add Drive Enclosure"
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 26
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Configure Expansion Drive Enclosure (2) This is also a Wizard driven procedure Start with Next
27
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Configure Expansion Drive Enclosure (3) This step is to verify that the Drive Enclosure is properly
installed in the rack
28
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Configure Expansion Drive Enclosures (4)
The Software Wizard scans automatically for new Drive Enclosures
29
Configure Expansion Drive Enclosure (5) This step is for verifying that the Auto Power Switch is set to
"Off" The switch is located in the Operation Panel
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 30
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
Configure Expansion Drive Enclosure (6) The Expansion for the Drive Enclosure is finished
31
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2
End of Initial Configuration Before logging off from the ETERNUS DX60 S2 Web GUI,
verify that all components have a condition "Normal" General status of the system in the Web GUI is "Normal" i.e. green All system LEDs are showing normal system status
32
ETERNUS SF To use the DX60 S2 with ETERNUS SF software, patch
v14.2A needs to be installed on the software server ETERNUS SF Express ETERNUS SF AdvancedCopy Manager ETERNUS SF Storage Cruiser
DX60 S2 starts shipping with SF Express v14.2 that will be replaced by v15.0 as soon as it becomes available
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 33
Additional Reading Instructions for Rack installation, initial Setup and initial
configuration ETERNUS DX60 S2 Disk Storage System, User's Guide, Site Planning
• P3AM-5492-03ENZ0 • Link to document
ETERNUS Web GUI, User's Guide, ETERNUS DX60 S2 • P2X0-1120-01ENZ0 • Link to document
ETERNUS DX60 S2 Disk Storage System, User's Guide, Installation • P3AM-5502-02ENZ0 • Link to document
ETERNUS documentation in Fujitsu PRIMEWEB Link to Fujitsu PRIMEWEB
Please note that accessing the above links require a Fujitsu Partner user account
Copyright Fujitsu Technology Solutions, Release September 2011 Hardware and Software Installation ETERNUS DX60 S2 34