eionet / dg soer ministry of ecology and sustainable development november 2006 water directorate...

11
EIONET / DG SOER Ministry of Ecology and Sustainable Development November 2006 Water Directorate Data management for SOE in France René Lalement WIS-France Taskforce

Upload: jason-nichols

Post on 31-Dec-2015

213 views

Category:

Documents


0 download

TRANSCRIPT

EIONET / DG SOER

Ministry of Ecology and Sustainable

Development

November 2006

Water Directorate

Data managementfor SOE in France

René LalementWIS-France Taskforce

EIONET / DG SOER

Ministry of Ecology and Sustainable

Development

November 2006

Water Directorate

Data management

Multiple data producers (12 competent authorities, 6 water agencies, 4 specialised institutes, 150 laboratories, ... )

Multiple data bases

Common uses -> needs for• interoperability• reliability• comparability• sustainability

Solved by a common reference framework (« Sandre » framework)

EIONET / DG SOER

Ministry of Ecology and Sustainable

Development

November 2006

Water Directorate

Common reference framework

• Extensive data dictionaries and data models

• Reference datasets

• Data exchange formats: EDI frames then XML

• Metadata: business md, then regular ISO 19115

• Data services: for reference datasets (web services: SOAP, REST) and monitoring results (2007)

See www.sandre.eaufrance.fr

EIONET / DG SOER

Ministry of Ecology and Sustainable

Development

November 2006

Water Directorate

Data dictionary

What is a “sample” ?

Conceptual interoperability (or human interoperability)

At discursive level:

• Definition • Rules and constraints on participating processes and actors• Components

EIONET / DG SOER

Ministry of Ecology and Sustainable

Development

November 2006

Water Directorate

Data dictionary

What is a sample ?

EIONET / DG SOER

Ministry of Ecology and Sustainable

Development

November 2006

Water Directorate

Reference dataset

What substance does CAS number 15972-60-8 refer to ?

Binding tables: • international level: ISO, ESTAT, CAS, ...• national level: Sandre,...

For : RBD, waterbodies, monitoring stations, UWWTP, ...

EIONET / DG SOER

Ministry of Ecology and Sustainable

Development

November 2006

Water Directorate

Data model

From discursive to formal level: • conceptual diagram (or UML class diagram)• does not capture everything

then • XML schema for exchange scenario

syntactic interoperability (or human aided machine interoperability: allows for a common data repository)

then • Web services (with XML payload)

EIONET / DG SOER

Ministry of Ecology and Sustainable

Development

November 2006

Water Directorate

EIONET / DG SOER

Ministry of Ecology and Sustainable

Development

November 2006

Water Directorate

<xs:element name="Echantillon" maxOccurs="unbounded"> <xs:complexType> <xs:sequence> <xs:element name="RefEchantillonCommanditaire" type="sa_lab:RefEchantillonCommanditaire" minOccurs="0"/> <xs:element name="RefEchantillonPrel" type="sa_lab:RefEchantillonPrel" minOccurs="0"/> <xs:element name="RefEchantillonLabo" type="sa_lab:RefEchantillonLabo" minOccurs="0"/> <xs:element name="DateReceptionEchant" type="sa_lab:DateReceptionEchant" minOccurs="0"/> <xs:element name="Laboratoire"> <xs:element name="Contact" minOccurs="0">...</xs:element>

EIONET / DG SOER

Ministry of Ecology and Sustainable

Development

November 2006

Water Directorate

Service oriented architecture

One data portal may give access to multiple service providers.

One service providers may supply data to multiple data portals.

EIONET / DG SOER

Ministry of Ecology and Sustainable

Development

November 2006

Water Directorate

Quality assurance & control

• Accreditation (ISO 17025) of laboratories is mandatory, including inter-lab comparisons

• By the French accreditation body or any European equivalent body

• Extended accreditation audits check additional requirements (LoQ, ...) from FR/EU regulations

• Analyses must be done under the accreditation conditions

• Analytic performances and traceability of results are implemented in the data exchange scenario