ec-type examination certificate...to this certificate. (11) this ec-type examination certificate...

4
L.M.J. Vries Certification Manager © This Certificate may only be reproduced in its entirety and without any change KEMA Registered Quality B.V. Utrechtseweg 310, 6812 AR Arnhem, The Netherlands P.O. box 9035, 6800 ET Arnhem, The Netherlands Telephone +31 26 3 56 34 28, Telefax +31 26 3 52 58 00 ACCREDITED BY THE DUTCH COUNCIL FOR ACCREDITATION eec.con 00-09-01 Page 1/4 (1) EC-TYPE EXAMINATION CERTIFICATE (2) Equipment or protective system intended for use in potentially explosive atmospheres – Directive 94/9/EC (3) EC-Type Examination Certificate Number: KEMA 00ATEX2088 (4) Equipment or protective system: Squirrel-cage induction motor type 5RE160… (5) Manufacturer: Rotor B.V. (6) Address: Mors 2, 7151 MX, Eibergen, The Netherlands (7) This equipment or protective system and any acceptable variation thereto is specified in the schedule to this certificate and the documents therein referred to. (8) KEMA, notified body number 0344 in accordance with Article 9 of the Council Directive 94/9/EC of 23 March 1994, certifies that this equipment or protective system has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment and protective systems intended for use in potentially explosive atmospheres given in Annex II to the Directive. The examination and test results are recorded in confidential report no. 2005200. (9) Compliance with the Essential Health and Safety Requirements has been assured by compliance with: EN 50014 : 1997 + A1, A2 and prA3 EN 50019 : 1994 + prA1 and prA2 (10) If the sign ”X” is placed after the certificate number, it indicates that the equipment or protective system is subject to special conditions for safe use specified in the schedule to this certificate. (11) This EC-Type Examination Certificate relates only to the design and construction of the specified equipment or protective system. If applicable, further requirements of this Directive apply to the manufacture and supply of this equipment or protective system. (12) The marking of the equipment or protective system shall include the following: II 2 G EEx e II T3…T1 Arnhem, 8 September 2000 by order of the Board of Directors of N.V. KEMA

Upload: others

Post on 22-Jun-2020

13 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EC-TYPE EXAMINATION CERTIFICATE...to this certificate. (11) This EC-Type Examination Certificate relates only to the design and construction of the specified equipment or protective

L.M.J. Vries

Certification Manager

© This Certificate may only be reproduced in its entirety and without any change

KEMA Registered Quality B.V.Utrechtseweg 310, 6812 AR Arnhem, The NetherlandsP.O. box 9035, 6800 ET Arnhem, The NetherlandsTelephone +31 26 3 56 34 28, Telefax +31 26 3 52 58 00

ACCREDITED BY THEDUTCH COUNCIL FORACCREDITATION

eec.con

00-09-01

Page 1/4

(1) EC-TYPE EXAMINATION CERTIFICATE

(2) Equipment or protective system intended for use in potentially explosive atmospheres –Directive 94/9/EC

(3) EC-Type Examination Certificate Number: KEMA 00ATEX2088

(4) Equipment or protective system: Squirrel-cage induction motor type 5RE160…

(5) Manufacturer: Rotor B.V.

(6) Address: Mors 2, 7151 MX, Eibergen, The Netherlands

(7) This equipment or protective system and any acceptable variation thereto is specified inthe schedule to this certificate and the documents therein referred to.

(8) KEMA, notified body number 0344 in accordance with Article 9 of the Council Directive94/9/EC of 23 March 1994, certifies that this equipment or protective system has beenfound to comply with the Essential Health and Safety Requirements relating to thedesign and construction of equipment and protective systems intended for use inpotentially explosive atmospheres given in Annex II to the Directive.

The examination and test results are recorded in confidential report no. 2005200.

(9) Compliance with the Essential Health and Safety Requirements has been assured bycompliance with:

EN 50014 : 1997 + A1, A2 and prA3 EN 50019 : 1994 + prA1 and prA2

(10) If the sign ”X” is placed after the certificate number, it indicates that the equipment orprotective system is subject to special conditions for safe use specified in the scheduleto this certificate.

(11) This EC-Type Examination Certificate relates only to the design and construction of thespecified equipment or protective system. If applicable, further requirements of thisDirective apply to the manufacture and supply of this equipment or protective system.

(12) The marking of the equipment or protective system shall include the following:

II 2 G EEx e II T3…T1

Arnhem, 8 September 2000by order of the Board of Directors of N.V. KEMA

Page 2: EC-TYPE EXAMINATION CERTIFICATE...to this certificate. (11) This EC-Type Examination Certificate relates only to the design and construction of the specified equipment or protective

(13) SCHEDULE (14) to EC-Type Examination Certificate KEMA 00ATEX2088

Page 2/4

(15) DescriptionSquirrel-cage induction motor type 5RE160...Construction according to EC-type Examination Certificate KEMA 00ATEX2080 U.Ambient temperature range -40 °C ... +40 °C.

Electrical data

Motor type 5RE160M02K 5RE160M02 5RE160L02 5RE160M04

Rated output (kW) 7,5 10 12,5 10

Rated voltage (V ± 5 %) 400 400 400 400

Rated current (A) 15,3 19,1 22,5 19,7

Rated frequency (Hz ± 2 %) 50 50 50 50

Power factor 0,84 0,91 0,92 0,87

Rated speed (rpm) 2940 2965 2930 1455

Insulation class F F F F

IA/IN 7,6 7,4 8,2 6,5

tE for T3 (s) 17 8 6 10

tE for T2 (s) 18 18 16 17

tE for T1 (s) 18 18 16 17

Motor type 5RE160L04 5RE160M06 5RE160L06

Rated output (kW) 13,5 6,6 9,7

Rated voltage (V ± 5 %) 400 400 400

Rated current (A) 26 16,3 23,5

Rated frequency (Hz ± 2 %) 50 50 50

Power factor 0,86 0,70 0,70

Rated speed (rpm) 1455 965 970

Insulation class F F F

IA/IN 7,5 5,0 6,3

tE for T3 (s) 5 9 6

tE for T2 (s) 12 24 18

tE for T1 (s) 12 24 18

Any voltage from 190 V up to and including 725 V is allowed if the electrical and thermal load areequal to those of the tested motor (a lower or the same current- and flux density).

Page 3: EC-TYPE EXAMINATION CERTIFICATE...to this certificate. (11) This EC-Type Examination Certificate relates only to the design and construction of the specified equipment or protective

(13) SCHEDULE (14) to EC-Type Examination Certificate KEMA 00ATEX2088

Page 3/4

Installation instructionsThe degree of protection of at least IP54 to EN 60034-5 is only achieved if certified cable entriesare used that are suitable for the application and correctly installed.Unused apertures shall be closed with suitable blanking elements.

The motor shall be provided with a three-phases inverse-delay overload protective device that notonly monitors the motor current but also disconnects the stalled motor within the above mentionedtE-times.

The motor shall only be used for continuous service, involving easy and infrequent starts which donot produce appreciable additional heating.

With built-in winding temperature sensors (DIN 44 082-M ...°C) in combination with a protectivedevice which is provided with the approval mark: PTB 3.53-PTC/A, the requirements of EN 50019,clause 4.7.4 are also fulfilled when the rotor is locked. At rated voltage and based on the cold state(20 °C) the delay time tA is as stated below:

Motor type 5RE160M02K 5RE160M04 5RE160M06 5RE160L06

Temperature sensor (°C) 100 120 120 120

Delay time tA (s) 21 23 28 23

Routine testsThe dielectric strength test according to Clause 17 of EN 60034-1 shall be carried out on eachmotor.

(16) ReportKEMA No. 2005200

(17) Special conditions for safe useNone.

(18) Essential Health and Safety Requirements

Essential Health and Safety Requirements not covered by the standards listed at (9)

Clause Subject

1.0.5 Marking

1.0.6 b and d Instructions

These Essential Health and Safety Requirements are examined and positively judged. Theresults are laid down in the report listed at (16)

Page 4: EC-TYPE EXAMINATION CERTIFICATE...to this certificate. (11) This EC-Type Examination Certificate relates only to the design and construction of the specified equipment or protective

(13) SCHEDULE (14) to EC-Type Examination Certificate KEMA 00ATEX2088

Page 4/4

(19) Test documentation

1. EC-Type Examination CertificateCertificate of Conformity

KEMA 00ATEX2080 UKEMA No. Ex-98.E.4595KEMA No. Ex-98.E.4596KEMA No. Ex-98.E.4597KEMA No. Ex-98.E.4599KEMA No. Ex-98.E.4604KEMA No. Ex-98.E.4616KEMA No. Ex-98.E.4617