e001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on...

18
XX F= NON-FUSED DISCONNECT SWITCH FUSED DISCONNECT SWITCH IN AN ENCLOSURE UNFUSED DISCONNECT SWITCH IN AN ENCLOSURE BRANCH PANELBOARD AVAILABLE SYMMETRICAL FAULT CURRENT FEEDER DESIGNATION, REFER TO FEEDER SCHEDULE ON DRAWINGS ONE LINE DIAGRAM LEGEND SYMBOL DESCRIPTION GENERAL ABBREVIATIONS ABBREVIATION B LIGHTING DESIGNATION - REFER TO LUMINAIRE SCHEDULE DESCRIPTION SYMBOL POWER CIRCUITING DESIGNATION, X: REFER TO PANEL SCHEDULE ABBREVIATION KEY, PER DRAWING. 1: CIRCUIT NUMBER. X:1 DEVICE, JUNCTION BOX, FLOOR BOX, ETC. DESCRIPTION SYMBOL LIGHTING CIRCUITING DESIGNATION, X: REFER TO PANEL SCHEDULE ABBREVIATION KEY, PER DRAWING. 1: CIRCUIT NUMBER. X:1 POWER CIRCUITING GUIDE LIGHTING CIRCUITING GUIDE CONDUIT STUB CONDUIT TURNED DOWN CONDUIT TURNED UP DOUBLE DUPLEX RECEPTACLE (20A, 125V) AT 18" AFF, UON, TYPE AS INDICATED ON DRAWINGS DUPLEX RECEPTACLE (20A, 125V) AT 18" AFF, UON DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER TYPE AT 18" AFF, UON ELECTRICAL CONNECTION TO EQUIPMENT ITEM 'E-1' (LETTER DESIGNATION AS APPLICABLE) - SEE CORRESPONDING EQUIPMENT CONNECTION SCHEDULE CONDUIT INSTALLED BELOW GRADE OR BELOW FINISHED FLOOR WIRING DEVICE SYMBOL LEGEND SYMBOL DESCRIPTION DOUBLE DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER TYPE AT 18" AFF, UON E-1 E-1 DOUBLE DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER TYPE ON EMERGENCY BRANCH CIRCUIT AT 18" AFF, UON DUPLEX RECEPTACLE (20A, 125V) MOUNTED 8" ABOVE COUNTER, UON DOUBLE DUPLEX RECEPTACLE (20A, 125V) MOUNTED 8" ABOVE COUNTER, UON DOUBLE DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER MOUNTED 8" ABOVE COUNTER, UON DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER MOUNTED 8" ABOVE COUNTER, UON DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER ON EMERGENCY BRANCH CIRCUIT MOUNTED 8" ABOVE COUNTER, UON DOUBLE DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER ON EMERGENCY BRANCH CIRCUIT MOUNTED 8" ABOVE COUNTER, UON SINGLE OR THREE PHASE MOTOR - SEE DRAWINGS FOR DESCRIPTION JUNCTION BOX - MOUNTING HEIGHT AND SIZE AS REQUIRED BY CODE OR AS NOTED ON DRAWINGS SURFACE RACEWAY - REFER TO DRAWINGS FOR REQUIREMENTS J SWITCH (20A, 120/277V, SINGLE POLE) AT 44" CL AFF, UON 'K' = KEY OPERATED 'MS' = MANUAL MOTOR STARTER - SURFACE MOUNTED '3' = THREE-WAY '4' = FOUR-WAY 'P' = PILOT LIGHT DIMMER, 0-10V UON AT 44" CL AFF, UON '3' = THREE-WAY LUMINAIRE - MOUNTED AS INDICATED ON DRAWINGS LUMINAIRE - AT CEILING, SURFACE OR RECESSED MOUNTED LUMINAIRE - WALL MOUNTED AT HEIGHT AS INDICATED ON DRAWINGS LUMINAIRE - AT CEILING, SURFACE OR RECESSED MOUNTED EXIT SIGN WITH INDICATING FACE [WIRED AHEAD OF LOCAL CONTROL] - CEILING MOUNTED EXIT SIGN WITH INDICATING FACE AND ARROW(S) [WIRED AHEAD OF LOCAL CONTROL] - WALL MOUNTED EMERGENCY LIGHTING BATTERY PACK [WIRED AHEAD OF LOCAL CONTROL] - SURFACE MOUNTED LIGHTING & CONTROL SYMBOL LEGEND SYMBOL DESCRIPTION NON-FUSED DISCONNECT SWITCH IN AN ENCLOSURE FUSED DISCONNECT SWITCH IN AN ENCLOSURE AUTOMATIC TRANSFER SWITCH METER ATS 3$1(/%2$5' <9 :,5( DISTRIBUTION SYMBOL LEGEND SYMBOL DESCRIPTION M FIRE ALARM PULL STATION AT 44" AFF, UON FIRE ALARM AUDIO/VISUAL DEVICE ROUGH-IN SUCH THAT BOTTOM OF VISUAL LENS IS NO LESS THAN 80" AFF 'H' = HORN FIRE ALARM VISUAL DEVICE ROUGH-IN SUCH THAT BOTTOM OF LENS IS NO LESS THAN 80" AFF FIRE ALARM SYSTEM MONITOR OF FLOW SWITCH - SPRINKLER SYSTEM FLOW SWITCH FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR FIRE ALARM SYSTEM MONITOR OF TAMPER SWITCH - SPRINKLER SYSTEM TAMPER SWITCH FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL CONTRACTOR FIRE ALARM ANNUNCIATOR PANEL - WALL MOUNTED AT 60" AFF TO CENTER, UON FIRE ALARM CONTROL PANEL - WALL MOUNTED AT 72" AFF TO TOP, UON FACP FAAP FIRE ALARM SMOKE DETECTOR - CEILING MOUNTED, UON FIRE ALARM SMOKE DETECTOR - WALL MOUNTED AT HEIGHT AS INDICATED ON DRAWINGS FIRE ALARM HEAT DETECTOR - CEILING MOUNTED, UON FIRE ALARM HEAT DETECTOR - WALL MOUNTED AT HEIGHT AS INDICATED ON DRAWINGS FIRE ALARM DUCT SMOKE DETECTOR WITH REMOTE TEST STATION - COORDINATE DUCT MOUNTING WITH THE MECHANICAL CONTRACTOR. LOCATE TEST STATION IN NEAREST ELECTRICAL ROOM AND PROVIDE ENGRAVED NAMEPLATE. 'EX' = EXHAUST DUCT 'R' = RETURN DUCT 'S' = SUPPLY DUCT F FIRE ALARM SYMBOL LEGEND SYMBOL DESCRIPTION DESCRIPTION 'DC' = DUAL TECHNOLOGY 'PS1' = PASSIVE INFRARED, SINGLE LEVEL SWITCHING, TWO LEVEL DETECTION LIGHTING CONTROL VACANCY SENSOR - CEILING MOUNTED LIGHTING CONTROL VACANCY SENSOR - WALL MOUNTED AT 44" CL AFF, UON 800/3 AF 800/3 AT MOLDED CASE CIRCUIT BREAKER WITH ADJUSTABLE TRIP PLUG x EDIT FOR METERING 400/3 MOLDED CASE CIRCUIT BREAKER (NON-ADJUSTABLE) x EDIT FOR METERING FUSIBLE SWITCH AND FUSE SIZE XXX EQUIPMENT ABBREVIATION, REFER TO EQUIPMENT ABBREVIATION SCHEDULE FOR ADDITIONAL INFORMATION TS FS a,b: SWITCHING SCHEME V V A AMPERES ADA AMERICANS WITH DISABILITIES ACT AF AMP FUSED AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AS AMP SWITCH BAS BUILDING AUTOMATION SYSTEM BFF BELOW FINISHED FLOOR C/B CIRCUIT BREAKER CATV COMMUNITY ANTENNA TELEVISION (CABLE TELEVISION) CL CENTER LINE CM CONSTRUCTION MANAGER EC ELECTRICAL CONTRACTOR EMT ELECTRICAL METALLIC TUBING ETR EXISTING ELECTRICAL DEVICE TO REMAIN GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER - PERSONNEL PROTECTION GFP GROUND FAULT PROTECTION HVAC HEATING, VENTILATING, AND AIR CONDITIONING KWC KILOWATTS CONNECTED KWD KILOWATTS DEMAND MC MECHANICAL CONTRACTOR MCB MAIN CIRCUIT BREAKER MLO MAIN LUGS ONLY NEC NATIONAL ELECTRICAL CODE NFPA NATIONAL FIRE PROTECTION ASSOCIATION NIC NOT IN CONTRACT OFE OWNER FURNISHED EQUIPMENT PC PLUMBING CONTRACTOR PHASE RD NEW LOCATION OF RELOCATED ELECTRICAL DEVICE REX REMOVE EXISTING ELECTRICAL DEVICE ALONG WITH RELATED CONDUIT AND WIRING, UON RR REMOVE AND RELOCATE EXISTING ELECTRICAL DEVICE AS SHOWN OR AS NOTED ON DRAWINGS TGB TELECOMMUNICATIONS GROUNDING BUSBAR UG UNDERGROUND UON UNLESS OTHERWISE NOTED V VOLTS W WIRE WP WEATHERPROOF SECURITY SYSTEM DOOR CONTACTS - MOUNTED AS INDICATED ON DRAWINGS GROUND SPEAKER ENCLOSURE RECESSED INTO FRONT WALL FURNISHED BY OTHERS INSTALLED BY E.C. PROVIDE 1" CONDUIT STUBBED INTO GREEN ROOM CEILING. VERIFY HEIGHT AND LOCATION OF ROUGH-IN FROM OWNER. MECHANICAL EQUIPMENT SCHEDULE DESCRIPTION VOLTAGE HP FLA KW CONN. WIRING PANEL CKT# SWITCH OR STARTER RATINGS: SWITCH / FUSE / STARTER NOTES BC CONTROLLER EF-1 EH-1 EH-2 FCU-1 FCU-2 FCU-3 FCU-4 FCU-5 SF-1 SF-3 208 120 208 208 208 208 208 120 120 120 120 1 1 1 1 1 1 1 1 1 1 1 - 1/2 - - - - - - - 1/2 1/2 0.5 9.8 14.4 0.0 0.5 0.5 0.5 0.8 0.8 9.8 9.8 0.1 1.2 3.0 0.0 0.1 0.1 0.1 0.1 0.1 1.2 1.2 DC DC - - DC - - - - DC DC 2#12 & 1#12G IN 3/4''C 2#12 & 1#12G IN 3/4''C 2#12 & 1#12G IN 3/4''C 2#12 & 1#12G IN 3/4''C 2#12 & 1#12G IN 3/4''C 2#12 & 1#12G IN 3/4''C 2#12 & 1#12G IN 3/4''C 2#12 & 1#12G IN 3/4''C 2#12 & 1#12G IN 3/4''C 2#12 & 1#12G IN 3/4''C 2#12 & 1#12G IN 3/4''C B07 B07 B15 B15 B07 B15 B07 B15 B15 B07 B07 12,14 15 2,4 5,7 12,14 19,21 12,14 3 3 16 17 - - - - - - - - - - - - - - - - - - - - - - MECHANICAL EQUIPMENT CONNECTION LEGEND CONN. DESCRIPTION DC - DIRECT CONNECTION. PROVIDE JUNCTION BOX AND SEALTITE CONNECTION. (MECHANICAL EQUIPMENT FURNISHED WITH INTEGRAL MEANS OF DISCONNECT) - A SHEET SIZE 24x36 J:\2016\167076\DELIVERABLES\DRAWINGS\ACAD\Erie Playhouse HVAC System Replacement\Sheets\Electrical\E-001 ELECTRICAL LEGEND, SCHEDULES & DETAILS.dwg SAVED: MNOLAN 2017-05-09 17:20 PLOT: 2017-05-10 10:03 REVISION PROJECT NO. DATE NO. DATE ERIE, PA 16506 4509 WEST RIDGE ROAD 13 WEST 10TH STREET 814-836-8500 ERIE, PENNSYLVANIA 16501 9 MAY 2017 1407 STAGE and RESTROOM RENOVATIONS E 001 ELECTRICAL LEGEND, SCHEDULES & DETAILS

Upload: others

Post on 06-Nov-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

XX

F=

NON-FUSED DISCONNECT SWITCH

FUSED DISCONNECT SWITCH IN AN ENCLOSURE

UNFUSED DISCONNECT SWITCH IN AN ENCLOSURE

BRANCH PANELBOARD

AVAILABLE SYMMETRICAL FAULT CURRENT

FEEDER DESIGNATION, REFER TO FEEDER SCHEDULE ON DRAWINGS

ONE LINE DIAGRAM LEGENDSYMBOL DESCRIPTION

GENERAL ABBREVIATIONSABBREVIATION

B

LIGHTING DESIGNATION - REFER TOLUMINAIRE SCHEDULE

DESCRIPTIONSYMBOL

POWER CIRCUITING DESIGNATION, X: REFER TO PANEL SCHEDULE ABBREVIATION KEY, PER DRAWING. 1: CIRCUIT NUMBER.

X:1

DEVICE, JUNCTION BOX, FLOOR BOX, ETC.

DESCRIPTIONSYMBOL

LIGHTING CIRCUITING DESIGNATION, X: REFER TO PANEL SCHEDULE ABBREVIATION KEY, PER DRAWING. 1: CIRCUIT NUMBER.

X:1

POWER CIRCUITING GUIDE

LIGHTING CIRCUITING GUIDE

CONDUIT STUB

CONDUIT TURNED DOWN

CONDUIT TURNED UP

DOUBLE DUPLEX RECEPTACLE (20A, 125V) AT 18" AFF, UON, TYPE AS INDICATED ONDRAWINGS

DUPLEX RECEPTACLE (20A, 125V) AT 18" AFF, UON

DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER TYPE AT 18"AFF, UON

ELECTRICAL CONNECTION TO EQUIPMENT ITEM 'E-1' (LETTER DESIGNATIONAS APPLICABLE) - SEE CORRESPONDING EQUIPMENT CONNECTION SCHEDULE

CONDUIT INSTALLED BELOW GRADE OR BELOW FINISHED FLOOR

WIRING DEVICE SYMBOL LEGENDSYMBOL DESCRIPTION

DOUBLE DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER TYPEAT 18" AFF, UON

E-1 E-1

DOUBLE DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER TYPEON EMERGENCY BRANCH CIRCUIT AT 18" AFF, UON

DUPLEX RECEPTACLE (20A, 125V) MOUNTED 8" ABOVE COUNTER, UON

DOUBLE DUPLEX RECEPTACLE (20A, 125V) MOUNTED 8" ABOVE COUNTER, UON

DOUBLE DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTERMOUNTED 8" ABOVE COUNTER, UON

DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER MOUNTED 8"ABOVE COUNTER, UON

DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER ON EMERGENCYBRANCH CIRCUIT MOUNTED 8" ABOVE COUNTER, UON

DOUBLE DUPLEX RECEPTACLE (20A, 125V) GROUND FAULT CIRCUIT INTERRUPTER ONEMERGENCY BRANCH CIRCUIT MOUNTED 8" ABOVE COUNTER, UON

SINGLE OR THREE PHASE MOTOR - SEE DRAWINGS FOR DESCRIPTION

JUNCTION BOX - MOUNTING HEIGHT AND SIZE AS REQUIRED BY CODE OR AS NOTED ONDRAWINGS

SURFACE RACEWAY - REFER TO DRAWINGS FOR REQUIREMENTS

J

SWITCH (20A, 120/277V, SINGLE POLE) AT 44" CL AFF, UON'K' = KEY OPERATED'MS' = MANUAL MOTOR STARTER - SURFACE MOUNTED'3' = THREE-WAY'4' = FOUR-WAY'P' = PILOT LIGHT

DIMMER, 0-10V UON AT 44" CL AFF, UON'3' = THREE-WAY

LUMINAIRE - MOUNTED AS INDICATED ON DRAWINGS

LUMINAIRE - AT CEILING, SURFACE OR RECESSED MOUNTED

LUMINAIRE - WALL MOUNTED AT HEIGHT AS INDICATED ON DRAWINGS

LUMINAIRE - AT CEILING, SURFACE OR RECESSED MOUNTED

EXIT SIGN WITH INDICATING FACE [WIRED AHEAD OF LOCAL CONTROL] - CEILINGMOUNTED

EXIT SIGN WITH INDICATING FACE AND ARROW(S) [WIRED AHEAD OF LOCAL CONTROL] -WALL MOUNTED

EMERGENCY LIGHTING BATTERY PACK [WIRED AHEAD OF LOCAL CONTROL] - SURFACEMOUNTED

LIGHTING & CONTROL SYMBOL LEGENDSYMBOL DESCRIPTION

NON-FUSED DISCONNECT SWITCH IN AN ENCLOSURE

FUSED DISCONNECT SWITCH IN AN ENCLOSURE

AUTOMATIC TRANSFER SWITCH

METER

ATS

PANELBOARD (208Y/120V, 3Ø, 4 WIRE)

DISTRIBUTION SYMBOL LEGENDSYMBOL DESCRIPTION

M

FIRE ALARM PULL STATION AT 44" AFF, UON

FIRE ALARM AUDIO/VISUAL DEVICE ROUGH-IN SUCH THAT BOTTOM OF VISUAL LENS IS NOLESS THAN 80" AFF

'H' = HORN

FIRE ALARM VISUAL DEVICE ROUGH-IN SUCH THAT BOTTOM OF LENS IS NO LESS THAN80" AFF

FIRE ALARM SYSTEM MONITOR OF FLOW SWITCH - SPRINKLER SYSTEM FLOW SWITCHFURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICALCONTRACTOR

FIRE ALARM SYSTEM MONITOR OF TAMPER SWITCH - SPRINKLER SYSTEM TAMPERSWITCH FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BYELECTRICAL CONTRACTOR

FIRE ALARM ANNUNCIATOR PANEL - WALL MOUNTED AT 60" AFF TO CENTER, UON

FIRE ALARM CONTROL PANEL - WALL MOUNTED AT 72" AFF TO TOP, UONFACP

FAAP

FIRE ALARM SMOKE DETECTOR - CEILING MOUNTED, UON

FIRE ALARM SMOKE DETECTOR - WALL MOUNTED AT HEIGHT AS INDICATED ONDRAWINGS

FIRE ALARM HEAT DETECTOR - CEILING MOUNTED, UON

FIRE ALARM HEAT DETECTOR - WALL MOUNTED AT HEIGHT AS INDICATED ON DRAWINGS

FIRE ALARM DUCT SMOKE DETECTOR WITH REMOTE TEST STATION - COORDINATE DUCTMOUNTING WITH THE MECHANICAL CONTRACTOR. LOCATE TEST STATION IN NEARESTELECTRICAL ROOM AND PROVIDE ENGRAVED NAMEPLATE.

'EX' = EXHAUST DUCT'R' = RETURN DUCT'S' = SUPPLY DUCT

F

FIRE ALARM SYMBOL LEGENDSYMBOL DESCRIPTION DESCRIPTION

'DC' = DUAL TECHNOLOGY

'PS1' = PASSIVE INFRARED, SINGLE LEVEL SWITCHING, TWO LEVEL DETECTION

LIGHTING CONTROL VACANCY SENSOR - CEILING MOUNTED

LIGHTING CONTROL VACANCY SENSOR - WALL MOUNTED AT 44" CL AFF, UON

800/3 AF800/3 AT

MOLDED CASE CIRCUIT BREAKER WITH ADJUSTABLE TRIP PLUG EDIT FOR METERING

400/

3 MOLDED CASE CIRCUIT BREAKER (NON-ADJUSTABLE) EDIT FOR METERING

FUSIBLE SWITCH AND FUSE SIZE

XXX

EQUIPMENT ABBREVIATION, REFER TOEQUIPMENT ABBREVIATION SCHEDULE FORADDITIONAL INFORMATION

TS

FS

a,b: SWITCHING SCHEME

V

V

A AMPERES

ADA AMERICANS WITH DISABILITIES ACT

AF AMP FUSED

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AS AMP SWITCH

BAS BUILDING AUTOMATION SYSTEM

BFF BELOW FINISHED FLOOR

C/B CIRCUIT BREAKER

CATV COMMUNITY ANTENNA TELEVISION (CABLE TELEVISION)

CL CENTER LINE

CM CONSTRUCTION MANAGER

EC ELECTRICAL CONTRACTOR

EMT ELECTRICAL METALLIC TUBING

ETR EXISTING ELECTRICAL DEVICE TO REMAIN

GC GENERAL CONTRACTOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER - PERSONNEL PROTECTION

GFP GROUND FAULT PROTECTION

HVAC HEATING, VENTILATING, AND AIR CONDITIONING

KWC KILOWATTS CONNECTED

KWD KILOWATTS DEMAND

MC MECHANICAL CONTRACTOR

MCB MAIN CIRCUIT BREAKER

MLO MAIN LUGS ONLY

NEC NATIONAL ELECTRICAL CODE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

OFE OWNER FURNISHED EQUIPMENT

PC PLUMBING CONTRACTOR

Ø PHASE

RD NEW LOCATION OF RELOCATED ELECTRICAL DEVICE

REX REMOVE EXISTING ELECTRICAL DEVICE ALONG WITH RELATED CONDUIT ANDWIRING, UON

RR REMOVE AND RELOCATE EXISTING ELECTRICAL DEVICE AS SHOWN OR AS NOTEDON DRAWINGS

TGB TELECOMMUNICATIONS GROUNDING BUSBAR

UG UNDERGROUND

UON UNLESS OTHERWISE NOTED

V VOLTS

W WIRE

WP WEATHERPROOF

SECURITY SYSTEM DOOR CONTACTS - MOUNTED AS INDICATED ON DRAWINGS

GROUND

SPEAKER ENCLOSURE RECESSED INTO FRONT WALL FURNISHED BY OTHERSINSTALLED BY E.C. PROVIDE 1" CONDUIT STUBBED INTO GREEN ROOM CEILING.VERIFY HEIGHT AND LOCATION OF ROUGH-IN FROM OWNER.

MECHANICAL EQUIPMENT SCHEDULEDESCRIPTION VOLTAGE Ø HP FLA KW CONN. WIRING PANEL CKT# SWITCH OR STARTER RATINGS:

SWITCH / FUSE / STARTER NOTES

BC CONTROLLER

EF-1

EH-1

EH-2

FCU-1

FCU-2

FCU-3

FCU-4

FCU-5

SF-1

SF-3

208

120

208

208

208

208

208

120

120

120

120

1

1

1

1

1

1

1

1

1

1

1

-

1/2

-

-

-

-

-

-

-

1/2

1/2

0.5

9.8

14.4

0.0

0.5

0.5

0.5

0.8

0.8

9.8

9.8

0.1

1.2

3.0

0.0

0.1

0.1

0.1

0.1

0.1

1.2

1.2

DC

DC

-

-

DC

-

-

-

-

DC

DC

2#12 & 1#12G IN 3/4''C

2#12 & 1#12G IN 3/4''C

2#12 & 1#12G IN 3/4''C

2#12 & 1#12G IN 3/4''C

2#12 & 1#12G IN 3/4''C

2#12 & 1#12G IN 3/4''C

2#12 & 1#12G IN 3/4''C

2#12 & 1#12G IN 3/4''C

2#12 & 1#12G IN 3/4''C

2#12 & 1#12G IN 3/4''C

2#12 & 1#12G IN 3/4''C

B07

B07

B15

B15

B07

B15

B07

B15

B15

B07

B07

12,14

15

2,4

5,7

12,14

19,21

12,14

3

3

16

17

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

MECHANICAL EQUIPMENT CONNECTION LEGENDCONN. DESCRIPTION

DC

-

DIRECT CONNECTION. PROVIDE JUNCTION BOX AND SEALTITE CONNECTION.(MECHANICAL EQUIPMENT FURNISHED WITH INTEGRAL MEANS OF DISCONNECT)

-

A

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-001

ELE

CTR

ICA

L LE

GE

ND

, SC

HE

DU

LES

& D

ETA

ILS

.dw

g

SA

VE

D: M

NO

LAN

201

7-05

-09

17:2

0 P

LOT:

201

7-05

-10

10:0

3

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E 001

ELECTRICAL LEGEND,SCHEDULES & DETAILS

Page 2: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

LUMINAIRE SCHEDULE - LED

TYPE MOUNTING LUMENS COLORTEMPERATURE CRI

TYPE QTY

DRIVER(S)

WATTAGE VOLTAGE LUMINAIRE DESCRIPTION ACCEPTABLEMANUFACTURERS NOTES

D1

D1A

ES

M2

R1

S1

SWL

WL1A

WS1

XP

RECESSED

RECESSED

SURFACE

SURFACE

PLASTER-IN

SURFACE

MOUNTING

CEILING

MOUNTING

SURFACE

1500

1500

NA

235

15440

5000

LUMENS

1500

LUMENS

NA

3500K

3500K

NA

2700K

2700K

4000K

COLORTEMPERATURE

400K

COLORTEMPERATURE

NA

80

80

NA

95+

95

80

CRI

80

CRI

NA

0-10V

0-10VOLT

NA

0-10V

LED

0-10V

DRIVER TYPE

0-10VOLT

DRIVER TYPE

LED

1

1

NA

1

1

1

DRIVERQTY

1

DRIVERQTY

1

21

21

20

5

80

42

114

21

0

5

120

120

120

120

120

120

120

120

0

120

LED 4" DIAMETER, 7.56" DEEP, MAX. OPEN REFLECTORRECESSED DOWNLIGHT WITH SELF-FLANGED, WHITEPAINTED FLANGE, LOW IRIDESCENT REFLECTOR, 3500K1500 LUMEN OUTPUT AND CLEAR TRIM RING.

LED 4" DIAMETER, 7.56" DEEP, MAX. OPEN REFLECTORRECESSED DOWNLIGHT WITH SELF-FLANGED, WHITEPAINTED FLANGE, LOW IRIDESCENT REFLECTOR, 3500K1500 LUMEN OUTPUT AND CLEAR TRIM RING. INTEGRALTEST SWITCH AND BATTERY PACK.

LED EMERGENCY SURFACE MOUNTED FIXTURE WITHWHITE POLYCARBONATE HOUSING, NICKEL CADMIUMBATTERY, 90 MINUTES MINIMUM BATTERY CAPACITY,BATTERY CHARGER, TEST SWITCH, INDICATOR LIGHTAND (2) ADJUSTABLE LAMP HEADS. PROVIDE HOBATTERY FOR POWERING REMOTE HEAD

LED 12" ROUND VERTICAL VANITY LIGHT, 2700K, SATINALUMINUM FINISH. DIMMABLE.

LED PLASTER-IN ROPE LIGHT. 2700K.

LED STRIPLIGHT 2.4"WX48" L X 3" H. WHITE ENAMELFINISH, 0-10V DIMMING. DROP LENS.

LED HIGHBAY 1' WIDE X 4' LONG X 2.68" DEEP

LED STRIPLIGHT 2.4"WX24" L X 3" H. WHITE ENAMELFINISH, 0-10V DIMMING. DROP LENS.

BLUE LED SCONCE

LED COMBINATION EXIT SIGN/EMERGENCY HEADS WITH6" RED LETTERS, CLEAR ACRYLIC PANELS, MIRROREDBACKGROUND FOR DOUBLE FACE SIGNS,THERMOPLASTIC HOUSING, FACES, ARROWS &MOUNTING AS INDICATED, NI-CAD BATTERY, BATTERYCHARGER, TEST SWITCH & INDICATOR LIGHT.

LITHONIA LDN435/ 15 L04 AR LSS120 EZ10 TRW

LITHONIA LDN435/ 15 L04 AR LSS120 EZ10 TRW EL

SURE-LITES CC5-NCLITHONIA QUANTUM 6ELM2 NEMERGI-LITE ESCORT ECCPRESCOLITE NV3N-9WLIGHTOLIER E2LIGHTGUARD U18N

EDGE LIGHTINGBV2-4RD-12IN-27K-SA

TRULINETL1.6A-5WDC-40-27K

LITHONIA ZL1D L48 5000LMFST MVOLT 40K 80 WH

LITHONIAIBGN 2400

LITHONIA ZL1D1500LM FST MVOLT 40K80CRI WH

MANUFACTURER

LITHONIA LHQM

3,5,8

3

NOTES

NOTES

NOTES

LUMINAIRE SCHEDULE - FLUORESCENT

TYPE MOUNTINGTYPE WATTS QTY

LAMP(S)

TYPE QTY

BALLAST(S)

WATTAGE VOLTAGE

FIXTURE

LUMINAIRE DESCRIPTION ACCEPTABLEMANUFACTURERS NOTES

M1

WS

SURFACE

MOUNTING

T5HO

LAMP TYP

(2) 39 & (2) 24

LAMP WATTS

4

LAMPQTY

E

BALLAST TYP

1

BALLASTQTY

126

0

120

0

FLUORESCENT LIGHTED MIRROR, LIGHT PROJECTEDFROM ALL 4 SIDES. DIMMABLE WITH A 0-10V DIMMER.2700K, 80 CRI.

FLUORESCENT WALL MOUNTED SCONCE. CAST COPPERFREE ALUMINUM HOUSING AND GUARD

EDGE LIGHTINGAVA-F1D

MANUFACTURER NOTES

1. PROVIDE POWER SUPPLY LOCATED ABOVE CEILING IN WORK ROOMFOR CONTROL.

2. PROVIDE MOUNTING AS CLOSE TO CEILING AS POSSIBLE AFTER ALLEQUIPMENT IS INSTALLED TO ACHIEVE BEST LIGHTING LEVELS.

3. AIM LUMINAIRES FOR OPTIMUM COVERAGE OF TASK AS DIRECTED INFIELD BY THE ARCHITECT.

4. VERIFY MOUNTING HEIGHT WITH ARCHITECT.

5. INSTALL LUMINAIRES AS RECOMMENDED BY THE MANUFACTURER'SINSTALLATION DRAWINGS.

6. MOUNTING HEIGHTS SHALL BE COORDINATED WITH ARCHITECTURALELEVATIONS AND DETAILS. PROVIDE ALL MOUNTING BACKBOXES ANDACCESSORIES AS RECOMMENDED BY LUMINAIRE PROVIDER . ALLCONDUIT SHALL BE CONCEALED. WHERE NOT POSSIBLE, ROUTEWITHIN STRUCTURE AS DIRECTED IN FIELD BY ARCHITECT. PAINTEXPOSED CONDUIT TO MATCH STRUCTURE. SEE DRAWINGS FORADDITIONAL MOUNTING REQUIREMENTS.

7. MOUNTED IN LAY-IN OR NON-LAY-IN INTERIOR OR EXTERIOR CEILING -VERIFY CONSTRUCTION TYPE WITH ARCHITECT AND PROVIDEPROPER MOUNTING ACCESSORIES.

8. ALTERNATES FOR FIXTURE WITHOUT EQUALS MUST BE PREAPPROVED BY ENGINEER AND ARCHITECT PRIOR TO BID. CENTEROVER BANNER LOCATION VERIFIED FROM ARCHITECT'S ELEVATION ORDETAIL DRAWINGS .

9. PROVIDE SAMPLE COLORS FOR TRIMS AND LENSES DURINGSUBMITTAL PROCESS FOR FINAL ARCHITECT APPROVAL .

10. INCLUDE IN SUBMITTAL INFORMATION ON TOTAL LENGTH PROVIDEDMANUFACTURER INSTALLATION DIAGRAMS, AND REQUIREDACCESSORIES FOR COMPLETE, SYSTEM WHICH WILL INTEGRATE WITHCEILING SYSTEM SHOWN ON REFLECTED CEILING PLANS.

11. ALL WALL MOUNTED EXIT LIGHTS SIGNS SHALL BE MOUNTEDCENTERED ABOVE DOORS BETWEEN DOORS AND CEILING WHEREPRACTICAL, OR AT A SIMILAR HEIGHT IF NOT ABOVE DOOR . EXIT SIGNSSHALL BE VISIBLE FOR EGRESS LIGHTING.

12. REMOTE HEADS SHALL MATCH POWER SUPPLY VOLTAGE.

13. IN HARD CEILING PROVIDE PLASTER MOUNTING ASSEMBLY ASRECOMMENDED BY MANUFACTURER.

LUMINAIRE SCHEDULE NOTES:

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-002

LIG

HTI

NG

FIX

TUR

E S

CH

ED

ULE

.dw

g

SA

VE

D: M

NO

LAN

201

7-05

-09

15:1

1 P

LOT:

201

7-05

-09

17:1

0

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E-002

LIGHTING FIXTURESCHEDULE

Page 3: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

LOWER LEVEL ELECTRICAL DEMOLITION PLAN

up

upup

6a1 2 3 4 5 6 7 8 9

A

B

C

D

OFFICEB16

MECHANICALB15

KITCHENETTEB14

WOMENB10

LOBBYB08

MECHANICALB07

LOBBYB06

MENB11

MENB12

GREEN RMB02

B01

STORAGEB13

MECH ROOM

OFFICEB05 OFFICE

B04

AHU-REXEF-REX

V

V

RR

AHU-REX2

1

4

6

35

DEMOLITION PLAN NOTES: DEMOLITION GENERAL NOTES:1. EXISTING MDP TO BE REMOVED AND REPLACED. SEE SHEET E801.

2. EXISTING COIN SHOP PANEL TO BE REMOVED AND REPLACED PANEL TO RENAMED P-B15 WITHNEW PANEL AND BACK BOX SEE SHEET 801 AND E100 FOR ADDITIONAL INFORMATION.

3. EXISTING LOWER MECHANICAL PANEL TO BE REMOVED AND REPALCED SEE SHEET 801

4. CONDENSATE PUMP REX.

5. REMOVE EXISTING LIGHTING AND ASSOCIATED SWITCHING IN ROOM.

6. EXISTING JUNCTION/PULLBOX FOR STAGE DIMMER, STAGE PANEL LOWER MECHANICALDISTRIBUTION PANEL TO REMAIN. REUTILIZE AS REQUIRED PROVIDE NEW COVER WHEN WORK ISCOMPLETE.

7. EXISTING HOT WATER TANK.

8. EXISTING SERVICE METERING (REX).

9. APPROXIMATE LOCATION OF CRAWL SPACE ACCESS.

10. EXISTING MECHANICAL ROOM PANEL TO REMAIN AND BE REFED FROM "MDP" AS SHOWN ONCONSTRUCTION DRAWING. PANEL TO BE RENAMED "P-BO7", SEE SHEET E801.

11. EXISTING GENERATOR PANEL TO REMAIN. PANEL TO BE RENAMED 'P-GEN.' SEE SHEET "E-801".

1. IN LOWER LEVEL BATHROOMS B10, B12, AND B13 REMOVE LIGHTING AND CONTROL.

2. FOR MECHANICAL EQUIPMENT SHOWN ON DRAWINGS. REMOVE ALL ASSOCIATED LIVE VOLTAGEPOWER CONNECTIONS ASSOCIATED WITH UNITS TO BE REMOVED AS SHOWN ON MECHANICALDRAWINGS.

3. REMOVE EXISTING FIRE ALARM SYSTEM DEVICES ON LEVELS SHOWN. COMPLETE TO EXISTINGCONTROL PANEL STAGE.

4. IT IS PERMITTED TO REWORK EXISTING FEEDER CONDUITS FOR DISTRIBUTION PANEL FOR NEWPANELS SHOWN ON CONSTRUCTION DRAWINGS.

X

AHU-REX

5

7

8

10

11ETR

ETR

SF-REX

4

9

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

D-1

00 L

OW

ER

LE

VE

L E

LEC

TRIC

AL

DE

MO

LITI

ON

PLA

N.d

wg

SA

VE

D: M

NO

LAN

201

7-05

-08

14:2

1 P

LOT:

201

7-05

-09

17:1

0

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

ED 100

LOWER LEVEL ELECTRICALDEMOLITION PLAN

Page 4: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

MAIN LEVEL ELECTRICAL DEMOLITION PLAN

up

down

up

down

up

up

up

down

down

up

A1

C3

6a1 2 3 4 5 6 7 8 9

A

B

C

DCOATS101

LOBBY102

AUDITORIUM106

TICKET OFFICE105

TOILET103

AUDITORIUM - FIXED SEATS107

FRONT STAGE108 STAGE

109BACK STAGE110

TOILET104

TOILET111

BUSINESS OFFICE112

SOUND106

DEMOLITION PLAN NOTES:1. REMOVE ALL POWER AND BOXES FOR SOUND ALONG EXISTING ORCHESTRA

PIT AREA.

2. REMOVE ALL SURFACE WIREWAY, RECEPTACLES, SOUND SYSTEM BOXES ANDCONDUITS AND ALL RELOCATED CONDUITS UNDER AND ON FRONT STAGEAREA.

3. REMOVE ALL EQUIPMENT MOUNTED ON PROSCENIUM WALL.

4. STAGE LIGHT DIMMER RACK TO BE UPGRADED BY TEC SHEET TEC DRAWING.

5. HOUSE LIGHT DIMMER RACK ETR.

6. EXISTING FIRE ALARM / SECURITY PANEL TO BE RELOCATED TO EAST SIDE OFDOOR.

7. 400AMP DISCONNECT SWITCH TO BE REMOVED AND REPLACED WITH NEW FORFEED TO STAGE DIMMER.

8. EXISTING HOUSE PANEL TO REMAIN AND BE REFED FROM "MDP" AS SHOWN ONCONSTRUCTION DRAWINGS. PANEL TO BE RENAMED "P-101".

9. REMOVE LIGHTING FIXTURES IN TOILET ROOMS 103 AND 104.

10. REMOVE LIGHTING AND POWER IN EXISTING ROOM TO BE RENOVATED.

11. EXISTING 100AS FOR HOUSE LIGHTING PANEL TO BE REPLACED WITH NEWSWITCH.

12. EXISTING STAGE LIGHTING PANEL. DISCONNECT TO BE REMOVED.

13. EXISTING STAGE LIGHTING PANEL TO BE REMOVED AND REPLACED WITH NEWMCD PANEL. PANEL TO BE RENAMED "P-110" SEE SHEET.

14. EXISTING COLUMN MOUNTED PANEL TO BE REMOVED WITH EXISTING LOADSTO BE RE-CONNECTED TO NEW PANEL "P-110", SEE SHEET E801 AND E101.

15. EXISTING SWITCH FOR COLUMN MOUNTED PANEL (REX).

16. EXISTING UNUSED SWITCH (REX).

7

4

5

6

RR

RR

21

DEMOLITION GENERAL NOTES:1. REMOVE EXISTING FIRE ALARM SYSTEM SMOKE DETECTORS ON LEVEL SHOWN COMPLETE TO

EXISTING CONTROL PANEL ON STAGE.

X

10

3

3

8

9

9

14

11

1312

1516

REXREX

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

D-1

01 M

AIN

LE

VE

L E

LEC

TRIC

AL

DE

MO

LITI

ON

PLA

N.d

wg

SA

VE

D: M

WR

IGH

T 20

17-0

4-25

15:

56

PLO

T: 2

017-

05-0

9 17

:10

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

ED 101

MAIN LEVEL ELECTRICALDEMOLITION PLAN

Page 5: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

MEZZANINE LEVEL ELECTRICAL DEMOLITION PLAN

down

up

down

down

down

up

6a1 2 3 4 5 6 7 8 9

6a

A

B

C

D

EQUIPMENT202

MECHANICAL

SEATING201

UPPER

STORAGE203

TOILET205

DRESSING204

UPPER AUDITORIUM UPPER STAGE

1

DEMOLITION NOTES:1. REMOVE EXISTING ELECTRICAL SWITCH A&

ASSOCIATED LINE VOLTAGE ACCESSORIES TOCOMPRESSOR L9CATED ON THIS LEVEL.

2. REMOVE OR RELOCATE EXISTING ELECTRICALDEVICES ASSOCIATED WITH REMOVAL OF WALLS.

2

DEMOLITION NOTES:1. REMOVE EXISTING FIRE ALARM SYSTEM

DEVICES ON LEVEL SHOWN COMPLETE TOEXISTING CONTROL PANEL ON STAGE.

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

D-1

02 M

EZZ

AN

INE

LE

VE

L E

LEC

TRIC

AL

DE

MO

LITI

ON

PLA

N.d

wg

SA

VE

D: M

NO

LAN

201

7-05

-08

15:2

8 P

LOT:

201

7-05

-09

17:1

0

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

ED 102

MEZZANINE LEVELELECTRICAL DEMOLITIONPLAN

Page 6: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

UPPER LEVEL ELECTRICAL DEMOLITION PLAN

down

down

6a1 2 3 4 5 6 7 8 9

6a

A

B

C

D

DRESSING301

STORAGE307

LIGHT CONTROL306

REWIND305

UPPER AUDITORIUM / ATTIC AREA UPPER STAGE

TOILET304

SHOWER303

TOILET302

PLAN NOTES: GENERAL NOTES:1.) FOR MECHANICAL EQUIPMENT SHOWN ON DRAWING.

REMOVE ALL ASSOCIATED LIVE VOLTAGE POWER CONNECTIONS ASSOCIATED WITH UNITS TO BE REMOVED AS SHOWN ON MECHANICAL DRAWING.

2.) REMOVE EXISTING FIRE ALARM SYSTEM DEVICES ONLEVEL. SHOWN COMPLETE TO EXISTING CONTROL PANEL.

1.) REMOVE ALL LINE VOLTAGE FEEDS FOR BOILER CONNECTIONS AND RELATED ACCESSORIES.

2.) AT UPPER STAGE REMOVE FEEDER CONNECTIONS ANDWIRES TO EXISTING (3) STAGE ELECTRIC GRID IRONJUNCTION BOXES BACK TO STAGE DIMMER RACK. (4)EXISTING 3X4 STAGE LIGHTING FIXTURES (3) EXISTINGSTAGE LIGHTING PENDANTS AND (2) EXISTING BUILDINGSYSTEM SMOKE DETECTORS. FEEDER CONDUITS AREPERMITTED TO BE REUSED FOR FEEDING NEW THEATRICAL EQUIPMENT AS SHOWN ON E-103 AND TECDRAWINGS. E.C. SHALL PROTECT FEED CONDUITS DURING CONSTRUCTION FOR RE-USE AS REQUIRED.

3.) AT CAT WALK AREA REMOVE STAGE LIGHTING FEEDERCONNECTIONS AND WIRES BACK TO STAGE DIMMERRACK. FEEDER CONDUITS ARE PERMITTED TO BE RE-USED REUSED FOR RE-FEEDING THEATRICAL EQUIPMENT AS SHOWN ON E-103. E.C. SHALL PROTECTDURING CONSTRUCTION FOR RE-USE AS REQUIRED.

4.) AT HOUSE WALL TORMENTOR LOCATION AREA REMOVEFEEDER CONNECTIONS AND WIRES BACK TO STAGEDIMMER RACK. THESE CONNECTION BOXES ARE

LOCATED ABOVE CATWALK .FEEDER CONDUITS ARE PERMITTED TO BE RE-USED FOR RE-FEEDING NEW THEATRICAL EQUIPMENT AS SHOWN ON E-103. E.C. SHALL PROTECT DURING CONSTRUCTION FOR REUSE AS REQUIRED.

5.) REMOVE EXISTING ATTIC UPPER CATWALK TASK LIGHTING.

6.) EXISTING LIGHT CONTROL PANEL INTERIOR TO BE REMOVED WITH NEW INTERIOR TO BE INSTALLED ANDRECONNECTED. PANEL RENAMED P-306. SEE SHEETE-801.

7.) DISCONNECT EXISTING COMPRESSOR ON OPEN PORCHLEVEL

X

BOILERREX

1

SEC PAN

FCUREX

2

REXREX

REX

3

FOH

1

44

4 4

6

5

7

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

D-1

03 U

PP

ER

LE

VE

L E

LEC

TRIC

AL

DE

MO

LITI

ON

PLA

N.d

wg

SA

VE

D: M

NO

LAN

201

7-05

-08

11:0

7 P

LOT:

201

7-05

-09

17:1

0

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

ED 103

UPPER LEVEL ELECTRICALDEMOLITION PLAN

Page 7: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

ROOF ELECTRICAL DEMOLITION PLAN

6a1 2 3 4 5 6 7 8 9

6a

A

B

C

D

1

DEMOLITION PLAN NOTE:1. DISCONNNECT EXISTING EVAPORATOR

EF-ETR

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

D-1

04 R

OO

F E

LEC

TRIC

AL

DE

MO

LITI

ON

PLA

N.d

wg

SA

VE

D: M

WR

IGH

T 20

17-0

4-25

15:

56

PLO

T: 2

017-

05-0

9 17

:10

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

ED 104

ROOF ELECTRICALDEMOLITION PLAN

Page 8: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

Unexcavated

up

upup

C2

C1

B2

A2

A1

up

up

7b6a

C3

1 2 3 4 5 6 7 8 9

B1

A3

A

B

C

D

7a

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

LOWER LEVEL LIGHTING PLAN

Unexcavated

OFFICEB16

MECHANICALB15

KITCHENETTEB14

WOMENB10

LOBBYB08

MECHANICALB07

LOBBYB06

MENB11

MENB12

GREEN RMB02

B01B03

STORAGEB13

ORCHESTRA PIT MECH ROOM

OFFICEB05 OFFICE

B04

B16HYDRAULICS

M2 R1R1

M2

R1

M1 M1 M1

M1

M1

M1

M1

D1D1

D1D1A

D1D1

D1

D1D1A

D1

D1D1A

D1

D1

D1A

D1

D1

D1D1A

D1

R1

R1

WS1

WS1

WS1

WS1

WS1

S1

WS

WSWS

WS

WS

WS

WS

WS

WS

JJ

JJ

B15

P-GEN

B07

Unexcavated

up

upup

C2

C1

B2

A2

A1

up

up

7b6a

C3

1 2 3 4 5 6 7 8 9

B1

A3

A

B

C

D

7a

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

LOWER LEVEL POWER PLAN

GENERAL NOTES:1. ALL DEVICE LOCATIONS SHOWN

SHALL BE VERIFIED WITH ARCHITECTPRIOR TO INSTALLATION.

2. CIRCUIT ALL EMERGENCY/EXITLIGHTING UNSWITCHED AHEAD OFAREA BEING SERVED.

S1

S1

K

b

b

b

b

b

44

bc

V

V

V VDC

VDC

b

c

e

b

44

bc

J

J

a

a

b

PB02

3 d

S1

b

44"

44"

PB01

4

4

4

XPXP

XP

MDP

S1

S1

S1 S1

S1 S1

FCU-1

SF-1

EF-1

BC CONTROLLER

FCU-3

FCU-2

SF-3

S1

S1

S1

S1

g

g

g

g

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

g

4ee

e

e e

e e

ee

ee e

e

e

e

4e

d

d3

b

b

:9PB02

:8PB02

:7PB02

:6PB02

:5PB02

:3PB02

:2PB02

:1PB02 :1PB02

:4PB02:4PB02 :2PB02

44"

44"

44"

44"

44"

:NANA44"

:NANA

:NANA

:3PB02

44"

44"

PLAN NOTES:1. PROVIDE NEW HAND DRYER. DYSON

(AB14 WHITE). CIRCUIT AS SHOWN.

:9PB01 :9PB01

:9PB01:9PB01

:9PB01

:9PB01

:9PB01:9PB01:9PB01

:9PB01

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-100

LO

WE

R L

EV

EL

ELE

CTR

ICA

L P

LAN

.dw

g

SA

VE

D: M

NO

LAN

201

7-05

-09

10:4

7 P

LOT:

201

7-05

-09

17:1

1

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E 100

LOWER LEVEL ELECTRICALPLAN

Page 9: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

MAIN LEVEL ELECTRICAL PLAN

up

down

up

down

up

up

up

down

down

up

down

down

up

A1

C3

6a1 2 3 4 5 6 7 8 9

A

B

C

D

Lift

COATS101

LOBBY102

AUDITORIUM106

TICKET OFFICE105

TOILET103

AUDITORIUM - FIXED SEATS107

FRONT STAGE108

STAGE109

BACK STAGE110

TOILET104

TOILET111

BUSINESS OFFICE112

SOUND106

WS1

D1AD1D1 D1D1

D1

D1

D1

D1

D1D1A

D1

M1M1

D1

A

A

A

F

F

F

F

F

F

F

FACP

FACPP110

P101P101A

A

A

PLAN NOTES:1. NEW 100 AMP FUSIBLE SWITCH FOR HOUSE

LIGHT DIMMER RACK. MOUNT ON WALL AND FEED FROM AUXILARY WIREWAY BENEATH.

2. EXISTING STAGE DIMMER RACKREFURBISHED BY TEC.

3. EXISTING HOUSE LIGHT DIMMER RACK TOREMAIN .

4. NEW 400AMP FUSED DISCONNECT SWITCHFOR STAGE DIMMER PANEL.

5 NEW STAGE TOUCH SCREEN PANEL. MOUNTED AND WIRED BY EC. TOUCH SCREEN PANEL FURNISHED BY TEC. SEE DETAIL ON E-103,

6. CIRCUIT LIGHTING TO A NEW 20 /1 IN PANEL P110. WITH # 12 WIRE.

7. PROVIDE CIRCUIT FOR DMX/RDM HUBFURNISHED BY TEC. MOUNTED ANDCIRCUITED BY EC.

4

2

3

1

5EF-2

EH-3

110CD

110CD

110CD

110CD110CD

60CD

60CD

VPS1

6

J

7

JEH-2

EH-1

FCU-4 FCU-5

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-101

MA

IN L

EV

EL

ELE

CTR

ICA

L P

LAN

.dw

g

SA

VE

D: M

WR

IGH

T 20

17-0

4-25

15:

56

PLO

T: 2

017-

05-1

0 10

:03

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E 101

MAIN LEVEL ELECTRICALPLAN

Page 10: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

MEZZANINE LEVEL ELECTRICAL PLAN

down

up

down

down

down

up

6a1 2 3 4 5 6 7 8 9

6a

A

B

C

D

EQUIPMENT202

MECHANICAL

SEATING201

UPPER

STORAGE203

TOILET205

DRESSING204

UPPER AUDITORIUM UPPER STAGE

F

FF

110CD

90CD

90CD

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-102

ME

ZZA

NIN

E L

EV

EL

ELE

CTR

ICA

L P

LAN

.dw

g

SA

VE

D: M

WR

IGH

T 20

17-0

4-25

15:

56

PLO

T: 2

017-

05-0

9 17

:11

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E 102

MEZZANINE LEVELELECTRICAL PLAN

Page 11: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

UPPER LEVEL ELECTRICAL PLAN

down

down

6a1 2 3 4 5 6 7 8 9

6a

A

B

C

D

DRESSING301

STORAGE307

LIGHT CONTROL306

REWIND305

UPPER AUDITORIUM

UPPER STAGE

TOILET304

SHOWER303

TOILET302

F

J

J

J

J

J

J J

J

2 2

2

3

3

3

3

3

NEW STAGE TORMENTOR (LEFT)

NEW STAGETORMENTOR (LEFT)

NEW FIRST STAGEELECTRIC

NEW SECOND STAGEELECTRIC

NEW THIRD STAGEELECTRIC

EXISTING TORMENTOR

GENERAL NOTES:1. SEE E-101 FOR ADDITIONAL EQUIPMENT REQUIREMENTS FOR

STAGE LIGHTING.

2. IT IS THE INTENT TO REUTILIZE EXISTING CONDUIT LINEVOLTAGE POWER FEEDS WITH NEW #10 WIRE INSTALLEDFROM STAGE DIMMER, ELECTRONICS, NEW AND EXISTINGTORMENTOR JUNCTION BOXES AND CATWALK LIGHTINGCONNECTIONS JUNCTION BOXES/ THE E.C. SHALL FIELDVERIFY FOR CODE COMPLIANT SUPPORTS AND GENERALINSTALLATION OF EXISTING FEEDS AND NOTIFY ENGINEERFOR DISCREPANCIES PRIOR TO REINSTALLING WIRING.VERIFY CONDITION OF CONDUIT AFTER EXISTING WIRING ISREMOVED AND NOTIFY ENGINEER IF DESCREPANCIES AREFOUND PRIOR TO REINSTALLATION OF NEW WIRING.

3. FOR STAGE LIGHTING WIRES PROVIDE NEW #10 WIRE FOR ALLCIRCUITS PLUS (1) GROUND WIRE FOR EACH CONDUIT RUN.SEE NEW CIRCUITING ON TEC DRAWING T3.01 FOR CIRCUITQUANTITIES AND LOCATIONS.

PLAN NOTES:1. MOUNT SMOKE DETECTOR AT TOP OF CATWALK .

2. APPROXIMATE LOCATION OF EXISTING GRID IRON JUNCTION BOXES FOREXISTING STAGE ELECTRONICS. E.C. SHALL DISCONNECT AND REMOVEEXISTING WIRE AND CONDUIT CONNECTION. PROVIDE EXISTING FEED CONDUITCONNECTION TO NEW GRID IRON JUNCTION BOX PROVIDED BY TEC ANDPROVIDE FINAL TERMINATION OF WIRES AS DIRECTED BY TEC AT ELECTRICLOCATION AND AT STAGE DIMMER

RACK (SHOWN ON E101).- FIRST ELECTRIC (18 CIRCUITS)- SECOND ELECTRIC ( 13 CIRCUITS)- THIRD ELECTRIC ( 11 CIRCUITS)

3. APPROXIMATE LOCATION OF CATWALK JUNCTION BOXES (5) TOTAL. E.C. SHALLREMOVE AND REPLACE EXISTING WIRE FROM EACH JUNCTION LOCATION TODIMMER AND PROVIDE FINAL TERMINATION OF FEED AS DIRECTED BY TEC ATCATWALK JUNCTION BOX AND AT STAGE DIMMER RACK. JUNCTION BOX ATCATWALK SHALL BE FURNISHED NEW BY TEC AND REMOUNTED BY E.C.

- CATWALK CIRCUIT (12 CIRCUITS)

4. AT APPROXIMATE LOCATION ABOVE CATWALK AT LEFT TORMENTOR JUNCTIONBOX LOCATION. REMOVE EXISTING WIRING AND CONDUIT CONNECTION.PROVIDE NEW WIRING AND EXISTING FEED CONDUIT RECONNECTION TO NEWJUNCTION BOX

(FURNISHED BY TEC MOUNTED BY E.C.) PROVIDE FINAL TERMINATIONS ASDIRECTED BY TEC FROM CATWALK JUNCTION BOX AND STAGE DIMMER RACK.

- LEFT TORMENTORS (6 CIRCUITS)

5. AT APPROXIMATE LOCATION ABOVE CATWALK AT RIGHT TORMENTORJUNCTION BOX LOCATION. REMOVE EXISTING WIRING AND CONDUITCONNECTION. PROVIDE NEW WIRING AND EXISTING FEED CONDUITRECONNECTION TO NEW JUNCTION BOX PROVIDED BY TEC AND PROVIDE FINALDIRECTED BY TEX AT CATWALK JUNCTION BOX AND STAGE DIMMER RACK.

- RIGHT TORMENTORS (6 CIRCUITS)

6. APPROXIMATE LOCATION OF FRONT WALL BOX (LEFT & RIGHT SIDE) CURRENTLYLOCATED ON PROSCENIUM WALL REMOVE BOX AND EXISTING CONDUIT FEEDFROM WALL. REMOVE BOX AND EXISTING CONDUIT FEED FROM WALL REMOUNTNEW JUNCTION BOX (FURNISHED BY TEC), RECONNECT CONDUIT FEED, ANDPROVIDE NEW WIRE AND TERMINATIONS FROM BOX TO STAGE DIMMER RACK.

- LS BOX 6 CIRCUITS.- RS BOX 6 CIRCUITS.

7. APPROXIMATE LOCATION OF PORTABLE WALL BOX (LEFT & RIGHT SIDE)CURRENTLY LOCATED ON EAST AND WEST STAGE WALL REMOVE BOX ANDEXISTING CONDUIT FEED FROM WALL. REMOVE BOX AND EXISTING CONDUITFEED FROM WALL REMOUNT NEW JUNCTION BOX (FURNISHED BY TEC),RECONNECT CONDUIT FEED AND PROVIDE NEW WIRE AND TERMINATIONSFROM BOX TO STAGE DIMMER RACK.

- LS BOX 6 CIRCUITS- RS BOX 6 CIRCUITS.

8. APPROXIMATE LOCATION OF REAR WALL BOX (LEFT & RIGHT SIDE) CURRENTLYLOCATED ON BACK STAGE WALL REMOVE BOX AND EXISTING CONDUIT FEEDFROM WALL. REMOVE BOX AND EXISTING CONDUIT FEED FROM WALL REMOUNTNEW JUNCTION BOX (FURNISHED BY TEC), RECONNECT CONDUIT FEED, ANDPROVIDE NEW WIRE AND TERMINATIONS FROM BOX TO STAGE DIMMER RACK.

- LS BOX 6 CIRCUITS- RS BOX 6 CIRCUITS.

9 LOCATION OF NEW DUAL DMX INPUT BOX FURNISHED BY TEC, MOUNTED ANDWIRED BY EC. SEE DETAIL ON SHEET E-103.

J

J

4

5

RTU PANEL P306

EXISTING TORMENTOR

8

F

PL

6

6

7

7

WS1

8

BT BT

BR BR

1

9

ION CONSOLE(EXISTING)

DMX/RDMHUB

LEFT STAGEWALL

P110:54

D

EXISTING DIMMERRACK CD80

CD 2000UPGRADE

TOUCH SCREENMANAGERS PANELLEFT STAGE WALL

P110:52

SIDE WALL TORMENTOR (R)

STAGE ELECTRIC -1

STAGE ELECTRIC -2

STAGE ELECTRIC -3

REAR TORMENTOR (R)

D

DDDDDDDD

DD

DUAL DMX INPUT(BOOTH)

REAR TORMENTOR (L)

FRONT TORMENTOR (R)

FRONT TORMENTOR (L)

DDFOH CATWALK

DDDDDDDDDD

SIDE WALL TORMENTOR (L)

F1

F1

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-103

UP

PE

R L

EV

EL

ELE

CTR

ICA

L P

LAN

.dw

g

SA

VE

D: M

NO

LAN

201

7-05

-10

09:5

6 P

LOT:

201

7-05

-10

10:0

3

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E 103

UPPER LEVEL ELECTRICALPLAN

Page 12: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

ATTIC LEVEL ELECTRICAL PLAN

6a1 2 3 4 5 6 7 8 9

6a

A

B

C

D

3Ka

PLAN NOTES:1. PROVIDE STROBE AT CATWALK ACCESS LOCATION.

2. PROVIDE 3 WAY SWITCH AT CATWALK LOCATION.

WL1A WL1A WL1A WL1A WL1A WL1Aa a a a a a

3 K

21

:1P306:1P306:1P306:1P306

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-104

ATT

IC L

EV

EL

ELE

CTR

ICA

L P

LAN

.dw

g

SA

VE

D: M

WR

IGH

T 20

17-0

4-25

15:

56

PLO

T: 2

017-

05-0

9 17

:11

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E 104

ATTIC LEVEL ELECTRICALPLAN

Page 13: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

6'4'2'0 8' 12' 16'

SCALE: 1/8" = 1'-0"

ROOF ELECTRICAL PLAN

6a1 2 3 4 5 6 7 8 9

6a

A

B

C

D

RTU-1

RTU-2

RTU-4

RTU-3

GENERAL NOTE:1.) DRAWNING INCLUDED FOR

INFORMATION ON EQUIPMENT LOCATIONS.

HP-1

WP

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-105

RO

OF

ELE

CTR

ICA

L P

LAN

.dw

g

SA

VE

D: M

WR

IGH

T 20

17-0

4-25

15:

56

PLO

T: 2

017-

05-0

9 17

:12

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E 105

ROOF ELECTRICAL PLAN

Page 14: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

BASIC ADDRESSABLE FIRE ALARM SYSTEM RISER

F F

FIRE ALARM POWER CIRCUITADDRESSABLE DEVICE COMMUNICATIONS CIRCUIT (COMM)

FACU

FAAP

PULLSTATION

HEATDETECTOR

DUCT SMOKEDETECTOR

BEAMDETECTORTRANSMITTERAND RECEIVER

3

6

12

F

CM

FS

M

BT BR

1. THE RISER DIAGRAM SHOWS THE INTENT OF THESE SPECIFICATIONS ANDSHALL BE USED AS A BASIS OF DESIGN. THE CONDUIT SIZING, TYPES ANDQUANTITY OF WIRES, SHALL BE VERIFIED WITH THE MANUFACTURER,PRIOR TO SUBMITTING A BID AND PRIOR TO INSTALLATION.

2. PROVIDE PERIPHERAL, ADDRESSABLE DEVICE WIRING FOR ALLADDRESSABLE INITIATING, INDICATING AND CONTROL DEVICES.MAINTAIN 15% SPARE CAPACITY ON ALL ADDRESSABLE COMMUNICATIONCHANNELS AND NOTIFICATION CIRCUITS.

3. ALL ADDRESSABLE CONTROL RELAYS AND MONITOR MODULES SHALL BEINSTALLED WITHIN 36" OF THE CONTROLLED OR MONITORED DEVICE.UNLESS OTHERWISE NOTED, ADDRESSABLE CONTROL RELAYS SHALLNOT ACTIVATE THE REQUIRED EMERGENCY CONTROL FUNCTION ONLOSS OF ADDRESSABLE CONTROL RELAY'S OPERATIONAL POWER.ADDRESSABLE CONTROL RELAYS USED TO SWITCH ANY VOLTAGEGREATER THAN 24VDC, REGARDLESS OF CONTACT RATING, SHALL USE ALISTED ISOLATION RELAY BETWEEN THE ADDRESSABLE CONTROL RELAYAND THE SWITCHED VOLTAGE. THE ISOLATION RELAY SHALL BEPOWERED BY FACU 24VDC AND ITS CONTACTS RATED FOR THE SPECIFICCONTROL APPLICATION. WHEN CONTROLLING AN ISOLATION RELAYFROM AN ADDRESSABLE DEVICE, THE ISOLATION RELAY BECOMES THECONTROLLED DEVICE AND MUST BE WITHIN 36' OF THE ADDRESSABLEDEVICE. THE INTERFACE FROM THE ISOLATION RELAY TO THECONTROLLED SYSTEM OR DEVICE HAS NO CODE DRIVEN DISTANCELIMITATIONS.

4. ALL CONTROL CABINETS SHALL BE GROUNDED, PER THE NATIONALELECTRICAL CODE REQUIREMENTS.

5. REFER TO FIRE ALARM SPECIFICATIONS FOR ADDITIONALREQUIREMENTS. REFER TO DRAWINGS FOR DEVICE LOCATIONS.

6. SMOKE DETECTORS SHALL NOT BE PLACED IN AREAS WHERE AIRFLOWPREVENTS PROPER OPERATION: DETECTORS SHOULD NOT BE LOCATEDCLOSER THAN 36" FROM AN AIR SUPPLY DIFFUSER OR RETURN AIROPENING.

X FIRE ALARM SYSTEM RISER NOTES:

SCALE: NONE

POWER CIRCUITADDRESSABLE DEVICE COMMUNICATION CIRCUIT (COMM)

MONITOR OF FIRESUPPRESSIONSYSTEM PIV

MONITOR OF FIRESUPPRESSIONSYSTEM FLOWSWITCH

1

8

AUDIBLE / VISUALNOTIFICATION APPLIANCES

VISUAL NOTIFICATIONAPPLIANCES

AUDIBLENOTIFICATION APPLIANCES

FACU 120VAC: SEE FLOORPLANS AND PANEL SCHEDULESFOR CIRCUIT INFORMATION.

9

FIRE ALARM SYSTEM GENERAL PLAN NOTES:

FIRE ALARM SYSTEM ABBREVIATION DEFINITIONS:

1. AFF -- ABOVE FINISHED FLOOR

3. DACT -- DIGITAL ALARM COMMUNICATOR TRANSMITTER

4. EC -- ELECTRICAL CONTRACTOR

5. FAAP -- FIRE ALARM ANNUNCIATOR PANEL

6. FACU -- FIRE ALARM CONTROL UNIT

7. S -- SPRINKLER WATERFLOW SWITCH

8. NACP -- NOTIFICATION APPLIANCE CONTROL PANEL

10. N / O -- NORMALLY OPEN (REFERRING TO RELAY CONTACTS)

12. POTS -- PLAIN OLD TELEPHONE SERVICE (VOICE-GRADE,ANALOG)

13. PS -- SPRINKLER PRESSURE SWITCH

14. R -- RELAY ISOLATION -- 24VDC, SPST

15. RAI -- REMOTE ALARM INDICATOR -- SINGLE LED ALARM OR"OFF-NORMAL" INDICATOR

16. RTS -- REMOTE TEST STATION -- COMPRISED OF KEYED TESTSWITCH AND LED

17. SPD -- SURGE PROTECTION DEVICE

18. TS -- SPRINKLER TAMPER SWITCH

2

DACT

4

14

MONITOR OF FIRESUPPRESSIONSYSTEM TS

M

TS

8

13

5

NACP

11

AUDIBLE AND / OR VISUALNOTIFICATION CIRCUITS ANDAPPLIANCES (NOT SPEAKERS)

3

SPRINKLER MONITOR TYPES

9

10

9

POWERCOMM

RAIRTS

R

R

RAI

5

M2

1. FACU: WHERE FLUSH MOUNTED CONTROL UNITS ARE SPECIFIED, (6) ADDITIONAL 3 / 4" CONDUITS SHALL BE STUBBED OUT INTO ACCESSIBLE CEILING SPACE FOR FUTURE USE. CONDUITS SHALL INCLUDE INSULATED BUSHING AND PULL STRING.

2. WHERE MULTIPLE FACU PANELS ARE REQUIRED AT ONE LOCATION WALL FIELD, THE EC SHALL COORDINATE ALL WALL FIELDREQUIREMENTS AND ADJUST ACCORDINGLY. ALL PANEL INTERCONNECTION OF THIS TYPE, SHALL BE IN CONDUIT.

3. OVERCURRENT PROTECTIVE DEVICE: 20 / 1, WITH "LOCK-ON" CLIP, 2 #12, 1 #12G, 3 / 4" C. USE LEGALLY REQUIRED LIFE SAFETYPOWER. MAINTAIN SEPARATION OF LOW VOLTAGE AND 120 VAC WIRING IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTION.PENETRATE CABINET ONLY IN THE KNOCKOUT SHOWN BY THE MANUFACTURER FOR 120 VAC. LIMITING AND NON-LIMITINGWIRING SHALL NOT BE BUNDLED TOGETHER.

4. DIGITAL ALARM COMMUNICATOR: FACU DACT TO SUPERVISING STATION COMMUNICATIONS: THE EC SHALL PROVIDE (2)STANDARD, 2 #24G, SEPARATE, DEDICATED, ANALOG, TELEPHONE LINES, TERMINATING IN (2) SEPARATE, RJ-11 JACKS, INSIDETHE FACU, FOR SUPERVISING STATION COMMUNICATIONS. BOTH PRIMARY AND SECONDARY LINES SHALL BE A TELEPHONECOMPANY (POTS) LINE AND TERMINATED UP STREAM FROM ANY PREMISES, PRIVATE TELEPHONE SYSTEM.

5.6. REMOTE ALARM INDICATOR (RAI): PROVIDE (RAI) FOR ALL CONCEALED, AND / OR NOT READILY ACCESSIBLE, DUCT DETECTORS,

BEAM DETECTORS, , TAMPER VALVE SWITCHES. PROVIDE FACU 24 VDC TO DEDICATED, OFF-NORMAL CONTACTS ONMONITORED DEVICE AND EXTEND WIRING FROM MONITORED DEVICE TO RAI'S REMOTE VISUAL INDICATOR. WIRE SUCH THATTHE VISUAL INDICATOR IS ILLUMINATED UPON DEVICE 'S ALARM / OFF-NORMAL ACTIVATION, AND AUTOMATICALLYEXTINGUISHES UPON MONITORED DEVICE'S RETURN TO NORMAL. PROVIDE BLACK TEXT ON WHITE, BRADY STYLE LABELING, ONREMOTE FACEPLATE, INDICATING THE ADDRESSABLE MONITORING DEVICE'S UNIQUE FACU ADDRESS AND TYPE OF DEVICEMONITORED DEVICE. MOUNTING REQUIREMENTS AS FOLLOWS:

UNFINISHED AREAS: SURFACE MOUNT ON ADJACENT WALL AT 7'6" AFF. COORDINATE INSTALLATION IN FINISHED AREAS WITH ARCHITECT / OWNER.

6. FAAP : PROVIDE AN FAAP LOCATED AT THE FIRE DEPARTMENT RESPONSE POINT(S) [AND OTHER LOCATIONS, AS SHOWN ONFLOOR PLANS.

7. NOTE NOT USED .

8. SUPPRESSION SYSTEM MONITORING: PROVIDE ADDRESSABLE, MONITOR MODULES TO MONITOR FOR ALARM ANDSUPERVISORY TROUBLE CONDITIONS. COORDINATE WITH SUPPRESSION SYSTEM PROVIDER FOR INTERFACE, INCLUDINGTYPES AND QUANTITY OF SYSTEM CONDITIONS TO MONITOR.

9. VISUAL NOTIFICATION APPLIANCES: SHALL BE TAPPED AT 15CD, UNLESS OTHERWISE NOTED ON FLOOR PLANS.

10 NOTE NOT USED.

10. NACP: (IF REQUIRED BY FIRE ALARM EQUIPMENT PROVIDER.) PROVIDE NACP WHERE SHOWN ON ON FLOOR PLANS.

11. NON-ADDRESSABLE, BEAM DETECTOR RECEIVER AND TRANSMITTER: MOUNT BEAM TRANSMITTER AND RECEIVER IN READILYACCESSIBLE LOCATIONS, WITH NO LINE-OF-SIGHT OBSTRUCTIONS, PER MANUFACTURER'S REQUIREMENTS. PROVIDE FIREALARM 24VDC TO TRANSMITTER AND RECEIVER. PROVIDE ADDRESSABLE MONITOR MODULE, IN READILY ACCESSIBLELOCATION FOR RECEIVER.

12. REMOTE ALARM TEST STATION (RTS): PROVIDE COMBINATION REMOTE ALARM TEST KEY SWITCH AND VISUAL ALARMINDICATOR FOR ALL DUCT DETECTORS THAT ARE USED FOR DAMPER CONTROL. FOR DUCT DETECTORS PROVIDE BLACK TEXTON WHITE, BRADY STYLE LABELING, ON RTS FACEPLATE, INDICATING THE DUCT DETECTOR'S UNIQUE FACU ADDRESS AND THEDESCRIPTOR FOR THE CONTROLLED DAMPER. MOUNTING REQUIREMENTS AS FOLLOWS:

UNFINISHED AREAS: SURFACE MOUNT ON ADJACENT WALL AT 7'6" AFF. COORDINATE INSTALLATION IN FINISHED AREAS WITH ARCHITECT / OWNER.

13. RELAY BASED DUCT DETECTOR: PROVIDE ADDRESSABLE, RELAY BASED DUCT DETECTOR FOR EACH RATED DAMPER AND / ORHVAC SHUTDOWN CONTROL LOCATION. COORDINATE CONNECTION AND HVAC UNIT AND / F/S OR DAMPER LOCATIONS WITHMECHANICAL CONTRACTOR. SEE GENERAL NOTE FOR ISOLATION RELAY REQUIREMENTS. FOR DAMPER CONTROL, DUCTDETECTOR SHALL BE INSTALLED WITHIN 5' OF PROTECTED DAMPER, WITH NO AIR INLETS OR OUTLETS BETWEEN DETECTORAND CONTROLLED RATED DAMPER. AT EACH DAMPER CONTROL DUCT DETECTOR, ALSO PROVIDE AN ADDRESSABLE MONITORMODULE(S) TO MONITOR THE OPEN AND CLOSED END-SWITCHES OF THE CONTROLLED DAMPER FOR STATUS.

14. CONTROL RELAY: PROVIDE ADDRESSABLE, PROGRAMMABLE, CONTROL RELAY AT EACH CONTROLLED HVAC UNIT AND / ORRATED DAMPER LOCATION. COORDINATE CONNECTIONS AND HVAC UNIT AND / OR DAMPER LOCATIONS WITH MECHANICALCONTRACTOR. SEE GENERAL NOTE FOR ISOLATION RELAY REQUIREMENTS.

SMOKEDETECTOR

10

M

SCALE: NONE

FIRE ALARMCONTROL UNIT

(FACU)

COMBINATION FIRE/SMOKE DAMPER WIRING DIAGRAM(WITH DUCT DETECTOR

C120V 120V

24V

CONTROL MODULE WITH120V TO 24V

PROVIDE TOGGLE SWITCHWITH PILOT LIGHT NEARDAMPER MOTOR LOCATIONAS LOCAL MEANS OFDISCONNECT

120V BRANCHCIRCUIT (6)DAMPERS PERCIRCUIT, MAXIMUM

SMOKE DAMPER

HVAC DUCT

DAMPER ACTUATORWITH POSITIONINDICATOR SWITCHES(POWERED IN OPENPOSITION)DUCT SMOKEDETECTOR, INSTALLWITHIN 5' OF DAMPERMONITOR MODULEFOR DAMPERPOSITION INDICATIONAT FACUT-TAP

REMOTE STATUS ALARM ANDDETECTOR TEST STATION

CABLING FOR TESTING KEY SWITCHAND CABLING FOR ALARM INDICATOR

COMMUNICATION CIRCUIT

PANEL P-110 CIRCUIT 54

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-601

ELE

CTR

ICA

L D

ETA

ILS

.dw

g

SA

VE

D: M

NO

LAN

201

7-04

-27

15:5

0 P

LOT:

201

7-05

-09

17:1

2

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E 601

ELECTRICAL DETAILS

Page 15: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

FIRE ALARM OPERATION MATRIX - SIGNALING AND NOTIFICATION

REQUIRED ACTION

FIRE ALARM CONTROL UNIT (FACU) / ANNUNCIATORS SUPERVISING STATION NOTIFICATION - INTERIOR NOTIFICATION -EXTERIOR MISC

SUPPLEMENTS SPECIFICATION SECTION 26 81 30CODE REF: OBC - 2011 / NFPA 72-2010

AU

DIB

LE A

ND

VIS

UA

L A

LAR

M S

IGN

AL

AT

PAN

EL

AU

DIB

LE A

ND

VIS

UA

LSU

PER

VISO

RY

SIG

NA

L A

TPA

NEL

AU

DIB

LE A

ND

VIS

UA

LTR

OU

BLE

SIG

NA

L A

T PA

NEL

DIS

PLA

Y C

OR

REC

T C

ON

DIT

ION

/ LO

CA

TIO

N IN

PLA

IN E

NG

LISH

REC

OR

D E

VEN

TS IN

SYST

EM L

OG

TRA

NSM

IT S

IGN

AL

TOSU

PER

VISI

NG

STA

TIO

N

TRA

NSM

IT S

IGN

AL

TOC

ENTR

AL

STA

TIO

N

AC

TUA

TE A

LL A

UD

IBLE

AN

D V

ISIB

LEN

OTI

FIC

ATI

ON

DEV

ICES

AC

TIVA

TE L

OC

AL

SOU

ND

ERS

FOR

ALL

DEV

ICES

IN S

UIT

E

DIS

CO

NN

ECT

FUEL

SO

UR

CE

FRO

M A

SSO

CIA

TED

CO

OK

ING

EQ

UIP

MEN

T

EXTE

RIO

R V

ISIB

LE D

EVIC

EA

CTI

VATE

S O

UTS

IDE

RIS

ERR

OO

M

TUR

N O

FF A

LL A

UD

IBLE

AN

D V

ISIB

LE N

OTI

FIC

ATI

ON

DEV

ICES

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

INITIATING DEVICES - GENERAL A

MANUAL ALARM PULL STATION B X X X X X X

SMOKE DETECTOR C X X X X X X

HEAT DETECTOR D X X X X X X

DUCT SMOKE DETECTOR E X X X X X

RESIDENTIAL SMOKE DETECTOR W/ SOUNDER F X X X X X

G

H

SUPPRESSION SYSTEMS I

WATERFLOW ALARM SWITCH J X X X X X X X

TAMPER SWITCH FOR CONTROL VALVE SUPERVISION K X X X X X

LOW AIR PRESSURE SUPERVISION L X X X X X

M

N

O

P

Q

R

LOSS OF OPERATING POWER FOR MORE THAN 60MINUTES X X X

MISC

SIGNAL SILENCE BUTTON X X

ALL TROUBLE CONDITIONS X X X X*

* DO NOT TRANSMIT LOSS OF PRIMARY POWER UNLESS POWER HAS NOT BEEN RESTORED FOR 60 MINUTES.

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

602

ELE

CTR

ICA

L D

ETA

ILS

.dw

g

SA

VE

D: M

WR

IGH

T 20

17-0

5-09

17:

05

PLO

T: 2

017-

05-0

9 17

:16

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E602E602

ELECTRICAL DETAILS

Page 16: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-701

ELE

CTR

ICA

L P

AN

EL

SC

HE

DU

LES

.dw

g

SA

VE

D: S

STO

ELT

ZIN

G 2

017-

05-0

9 16

:50

PLO

T: 2

017-

05-0

9 17

:12

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E 701

ELECTRICAL PANELSCHEDULES

CIRCUIT BREAKER PANEL SCHEDULE PANEL: P101 SHORT CIRCUIT

RATING: REFER TO 26 21 00 PROJ #: 2016-7076

VOLTAGE: 208/120V, 3 Ø, 4 W NUMBER OF POLES: 30 NAME:Erie Playhouse HVACSystem Replacement

BUS AMPS: 225 A MOUNTING: SURFACE DATE: 5/9/2017

MAINS: 225 A MLO NOTES: FED FROM MDP

# DESCRIPTION TYPE LOAD TRIPAMPS POLES Ø POLES TRIP

AMPS LOAD TYPE DESCRIPTION #

1 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 2

3 EXISTING <Undefined> 0 20 1 B 1 20 0 <Undefined> EXISTING 4

5 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 6

7 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 8

9 EXISTING <Undefined> 0 20 1 B 1 20 0 <Undefined> EXISTING 10

11 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 12

13 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 14

15 EXISTING <Undefined> 0 20 1 B 1 20 0 <Undefined> EXISTING 16

17 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 18

19 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 20

21 EXISTING <Undefined> 0 20 1 B 1 20 0 <Undefined> EXISTING 22

23 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 24

25 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 26

27 EXISTING <Undefined> 0 20 1 B 1 20 0 <Undefined> EXISTING 28

29 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 30

FTL PANEL P-101 <Undefined> 0 225 3 A ---- ---- ---- ---- ---- ----

FTL PANEL P-101 <Undefined> 0 225 3 B ---- ---- ---- ---- ---- ----

FTL PANEL P-101 <Undefined> 0 225 3 C

LOAD SUMMARY

kWC DF kWD DESIGNED LOAD 64.8 KW

DEMAND LOAD 0.0 KW

SPARE CAPACITY 64.8 KW

SPARE CAPACITY 180.0 AMPS

SPARE CAPACITY 100 %

TOTAL 0.0 0.0 PANEL LOADS TOTAL

AMPS 0.0 0.0 Phase A (W): ----Phase B (W): ----Phase C (W): ----

CIRCUIT BREAKER PANEL SCHEDULE PANEL: P110 SHORT CIRCUIT

RATING: REFER TO 26 21 00 PROJ #: 2016-7076

VOLTAGE: 208/120V, 3 Ø, 4 W NUMBER OF POLES: 54 NAME:Erie Playhouse HVACSystem Replacement

BUS AMPS: 225 A MOUNTING: SURFACE DATE: 5/9/2017

MAINS: 225 A MCB NOTES: FED FROM MDP

# DESCRIPTION TYPE LOAD TRIPAMPS POLES Ø POLES TRIP

AMPS LOAD TYPE DESCRIPTION #

1 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 2

3 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 4

5 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 6

7 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 8

9 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 10

11 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 12

13 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 14

15 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 16

17 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 18

19 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 20

21 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 22

23 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 24

25 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 26

27 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 28

29 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 30

31 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 32

33 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 34

35 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 36

37 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 38

39 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 40

41 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 42

43 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 44

45 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 46

47 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 48

49 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 50

51 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 52

53 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 54

LOAD SUMMARY

kWC DF kWD DESIGNED LOAD 64.8 KW

DEMAND LOAD 0.0 KW

SPARE CAPACITY 64.8 KW

SPARE CAPACITY 180.0 AMPS

SPARE CAPACITY 100 %

TOTAL 0.0 0.0 PANEL LOADS TOTAL

AMPS 0.0 0.0 Phase A (W): ----Phase B (W): ----Phase C (W): ----

CIRCUIT BREAKER PANEL SCHEDULE PANEL: PB01 SHORT CIRCUIT

RATING: REFER TO 26 21 00 PROJ #: 2016-7076

VOLTAGE: 208/120V, 3 Ø, 4 W NUMBER OF POLES: 30 NAME:Erie Playhouse HVACSystem Replacement

BUS AMPS: 400 A MOUNTING: SURFACE DATE: 5/9/2017

MAINS: 400 A MLO NOTES: FED FROM MDP

# DESCRIPTION TYPE LOAD TRIPAMPS POLES Ø POLES TRIP

AMPS LOAD TYPE DESCRIPTION #

1 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 2

3 EXISTING <Undefined> 0 20 1 B 1 20 0 <Undefined> EXISTING 4

5 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 6

7 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 8

9 LIGHTING LTG 1008 20 1 B 3 70 6600 HVAC RTU-3 10,12,14

11,13,15 RTU-4 HVAC 5040 50 3 C 3 70 6600 HVAC RTU-3 10,12,14

11,13,15 RTU-4 HVAC 5040 50 3 A 3 70 6600 HVAC RTU-3 10,12,14

11,13,15 RTU-4 HVAC 5040 50 3 B 1 20 0 <Undefined> ---- 16

17 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 18

19 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 20

21 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 22

23 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 24

25 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> SPARE 26

27 SPARE <Undefined> 0 20 1 B 1 20 0 <Undefined> SPARE 28

29 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 30

SFCB PANEL PB02 REC 1200 100 3 A ---- ---- ---- ---- ---- ----

SFCB PANEL PB02 REC 1000 100 3 B ---- ---- ---- ---- ---- ----

SFCB PANEL PB02 REC 400 100 3 C

LOAD SUMMARY

kWC DF kWD DESIGNED LOAD 129.7 KW

HVAC 34.9 1.00 34.9 DEMAND LOAD 38.5 KW

LTG 1.0 1.00 1.0 SPARE CAPACITY 91.2 KW

SPARE CAPACITY 253.1 AMPS

SPARE CAPACITY 70 %

TOTAL 38.5 38.5 PANEL LOADS TOTAL

AMPS 106.9 106.9 Phase A (W): 12840Phase B (W): 13648Phase C (W): 12040

CIRCUIT BREAKER PANEL SCHEDULE PANEL: PB02 SHORT CIRCUIT

RATING: REFER TO 26 21 00 PROJ #: 2016-7076

VOLTAGE: 208/120V, 3 Ø, 4 W NUMBER OF POLES: 42 NAME:Erie Playhouse HVACSystem Replacement

BUS AMPS: 225 A MOUNTING: SURFACE DATE: 5/9/2017

MAINS: 225 A MCB NOTES: FED FROM PB01

# DESCRIPTION TYPE LOAD TRIPAMPS POLES Ø POLES TRIP

AMPS LOAD TYPE DESCRIPTION #

1 ---- REC 400 20 1 A 1 20 400 REC ---- 2

3 ---- REC 400 20 1 B 1 20 400 REC ---- 4

5 ---- REC 200 20 1 C 1 20 200 REC ---- 6

7 ---- REC 200 20 1 A 1 20 200 REC ---- 8

9 ---- REC 200 20 1 B 1 20 0 <Undefined> ---- 10

11 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 12

13 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 14

15 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 16

17 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 18

19 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 20

21 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 22

23 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 24

25 SPARE <Undefined> 0 20 1 A 1 20 0 <Undefined> SPARE 26

27 SPARE <Undefined> 0 20 1 B 1 20 0 <Undefined> SPARE 28

29 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 30

31 SPARE <Undefined> 0 20 1 A 1 20 0 <Undefined> SPARE 32

33 SPARE <Undefined> 0 20 1 B 1 20 0 <Undefined> SPARE 34

35 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 36

37 SPARE <Undefined> 0 20 1 A 1 20 0 <Undefined> SPARE 38

39 SPARE <Undefined> 0 20 1 B 1 20 0 <Undefined> SPARE 40

41 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 42

LOAD SUMMARY

kWC DF kWD DESIGNED LOAD 64.8 KW

DEMAND LOAD 2.6 KW

SPARE CAPACITY 62.2 KW

SPARE CAPACITY 172.8 AMPS

SPARE CAPACITY 96 %

TOTAL 2.6 2.6 PANEL LOADS TOTAL

AMPS 7.2 7.2 Phase A (W): 1200Phase B (W): 1000Phase C (W): 400

SFCB = SUB FEED CIRCUIT BREAKER FTL = FEED THROUGH LUGS

CIRCUIT BREAKER PANEL SCHEDULE PANEL: P101A SHORT CIRCUIT

RATING: REFER TO 26 21 00 PROJ #: 2016-7076

VOLTAGE: 208/120V, 3 Ø, 4 W NUMBER OF POLES: 42 NAME:Erie Playhouse HVACSystem Replacement

BUS AMPS: 225 A MOUNTING: SURFACE DATE: 5/9/2017

MAINS: 225 A MLO NOTES: FED FROM P101

# DESCRIPTION TYPE LOAD TRIPAMPS POLES Ø POLES TRIP

AMPS LOAD TYPE DESCRIPTION #

1 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 2

3 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 4

5 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 6

7 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 8

9 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 10

11 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 12

13 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 14

15 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 16

17 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 18

19 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 20

21 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 22

23 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 24

25 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 26

27 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 28

29 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 30

31 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 32

33 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 34

35 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 36

37 ---- <Undefined> 0 20 1 A 1 20 0 <Undefined> ---- 38

39 ---- <Undefined> 0 20 1 B 1 20 0 <Undefined> ---- 40

41 ---- <Undefined> 0 20 1 C 1 20 0 <Undefined> ---- 42

LOAD SUMMARY

kWC DF kWD DESIGNED LOAD 64.8 KW

DEMAND LOAD 0.0 KW

SPARE CAPACITY 64.8 KW

SPARE CAPACITY 180.0 AMPS

SPARE CAPACITY 100 %

TOTAL 0.0 0.0 PANEL LOADS TOTAL

AMPS 0.0 0.0 Phase A (W): ----Phase B (W): ----Phase C (W): ----

CIRCUIT BREAKER PANEL SCHEDULE PANEL: B15 SHORT CIRCUIT

RATING: REFER TO 26 21 00 PROJ #: 2016-7076

VOLTAGE: 208/120V, 3 Ø, 4 W NUMBER OF POLES: 30 NAME:Erie Playhouse HVACSystem Replacement

BUS AMPS: 225 A MOUNTING: SURFACE DATE: 5/9/2017

MAINS: 225 A MLO NOTES: ----

# DESCRIPTION TYPE LOAD TRIPAMPS POLES Ø POLES TRIP

AMPS LOAD TYPE DESCRIPTION #

1 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 2

3 EXISTING <Undefined> 0 20 1 B 1 20 0 <Undefined> EXISTING 4

5 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 6

7 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 8

9 EXISTING <Undefined> 0 20 1 B 1 20 0 <Undefined> EXISTING 10

11 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 12

13 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 14

15 EXISTING <Undefined> 0 20 1 B 1 20 0 <Undefined> EXISTING 16

17 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 18

19,21 FCU-2 HVAC 50 20 2 A 1 20 0 <Undefined> SPARE 2019,21 FCU-2 HVAC 50 20 2 B 1 20 0 <Undefined> SPARE 22

23 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 24

25 SPARE <Undefined> 0 20 1 A 1 20 0 <Undefined> SPARE 26

27 SPARE <Undefined> 0 20 1 B 1 20 0 <Undefined> SPARE 28

29 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 30

LOAD SUMMARY

kWC DF kWD DESIGNED LOAD 64.8 KW

HVAC 0.1 1.00 0.1 DEMAND LOAD 0.1 KW

SPARE CAPACITY 64.7 KW

SPARE CAPACITY 179.7 AMPS

SPARE CAPACITY 100 %

TOTAL 0.1 0.1 PANEL LOADS TOTAL

AMPS 0.3 0.3 Phase A (W): 50Phase B (W): 50Phase C (W): 0

Page 17: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-702

ELE

CTR

ICA

L P

AN

EL

SC

HE

DU

LES

.dw

g

SA

VE

D: S

STO

ELT

ZIN

G 2

017-

05-0

9 16

:51

PLO

T: 2

017-

05-0

9 17

:16

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E 702

ELECTRICAL PANELSCHEDULES

CIRCUIT BREAKER PANEL SCHEDULE PANEL: B07 SHORT CIRCUIT

RATING: REFER TO 26 21 00 PROJ #: 2016-7076

VOLTAGE: 208/120V, 3 Ø, 4 W NUMBER OF POLES: 42 NAME:Erie Playhouse HVACSystem Replacement

BUS AMPS: 225 A MOUNTING: SURFACE DATE: 5/9/2017

MAINS: 225 A MLO NOTES: FED FROM MDP

# DESCRIPTION TYPE LOAD TRIPAMPS POLES Ø POLES TRIP

AMPS LOAD TYPE DESCRIPTION #

1,3,5 EXISTING <Undefined> 0 50 3 A 3 30 0 <Undefined> EXISTING 2,4,6

1,3,5 EXISTING <Undefined> 0 50 3 B 3 30 0 <Undefined> EXISTING 2,4,6

1,3,5 EXISTING <Undefined> 0 50 3 C 3 30 0 <Undefined> EXISTING 2,4,6

7,9 EXISTING <Undefined> 0 20 2 A 2 20 0 <Undefined> EXISTING 8,10

7,9 EXISTING <Undefined> 0 20 2 B 2 20 0 <Undefined> EXISTING 8,10

11,13 EXISTING <Undefined> 0 30 2 C 2 20 150 HVAC FCU-1,3, BCCONTROLLER

12,14

11,13 EXISTING <Undefined> 0 30 2 A 2 20 150 HVAC FCU-1,3, BCCONTROLLER

12,14

15 EF-1 HVAC 1176 20 1 B 1 20 1176 HVAC SF-1 16

17 SF-3 HVAC 1176 20 1 C 1 20 0 <Undefined> SPARE 18

19 SPARE <Undefined> 0 20 1 A 1 20 0 <Undefined> SPARE 20

21 SPARE <Undefined> 0 20 1 B 1 20 0 <Undefined> SPARE 22

23 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 24

25 SPARE <Undefined> 0 20 1 A 1 20 0 <Undefined> SPARE 26

27 SPARE <Undefined> 0 20 1 B 1 20 0 <Undefined> SPARE 28

29 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 30

31 SPARE <Undefined> 0 20 1 A 1 20 0 <Undefined> SPARE 32

33 SPARE <Undefined> 0 20 1 B 1 20 0 <Undefined> SPARE 34

35 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 36

37 SPARE <Undefined> 0 20 1 A 1 20 0 <Undefined> SPARE 38

39 SPARE <Undefined> 0 20 1 B 1 20 0 <Undefined> SPARE 40

41 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 42

LOAD SUMMARY

kWC DF kWD DESIGNED LOAD 64.8 KW

HVAC 3.8 1.00 3.8 DEMAND LOAD 3.8 KW

SPARE CAPACITY 61.0 KW

SPARE CAPACITY 169.4 AMPS

SPARE CAPACITY 94 %

TOTAL 3.8 3.8 PANEL LOADS TOTAL

AMPS 10.6 10.6 Phase A (W): 150Phase B (W): 2352Phase C (W): 1326

CIRCUIT BREAKER PANEL SCHEDULE PANEL: P306 SHORT CIRCUIT

RATING: REFER TO 26 21 00 PROJ #: 2016-7076

VOLTAGE: 208/120V, 3 Ø, 4 W NUMBER OF POLES: 23 NAME:Erie Playhouse HVACSystem Replacement

BUS AMPS: 225 A MOUNTING: SURFACE DATE: 5/9/2017

MAINS: 225 A MLO NOTES: FED FROM MDP

# DESCRIPTION TYPE LOAD TRIPAMPS POLES Ø POLES TRIP

AMPS LOAD TYPE DESCRIPTION #

1,3 EXISTING <Undefined> 0 20 2 A 1 20 0 <Undefined> EXISTING 2,4

1,3 EXISTING <Undefined> 0 20 2 B ---- ---- ---- ---- ---- ----

5 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 6

7 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 8

9 EXISTING <Undefined> 0 20 1 B 1 20 0 <Undefined> EXISTING 10

11 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 12

13 EXISTING <Undefined> 0 20 1 A 1 20 0 <Undefined> EXISTING 14

15 EXISTING <Undefined> 0 20 1 B 1 20 0 <Undefined> EXISTING 16

17 EXISTING <Undefined> 0 20 1 C 1 20 0 <Undefined> EXISTING 18

19 SPARE <Undefined> 0 20 1 A 1 20 0 <Undefined> SPARE 20

21 SPARE <Undefined> 0 20 1 B 1 20 0 <Undefined> SPARE 22

23 SPARE <Undefined> 0 20 1 C 1 20 0 <Undefined> SPARE 24

LOAD SUMMARY

kWC DF kWD DESIGNED LOAD 64.8 KW

DEMAND LOAD 0.0 KW

SPARE CAPACITY 64.8 KW

SPARE CAPACITY 180.0 AMPS

SPARE CAPACITY 100 %

TOTAL 0.0 0.0 PANEL LOADS TOTAL

AMPS 0.0 0.0 Phase A (W): ----Phase B (W): ----Phase C (W): ----

Page 18: E001€¦ · double duplex receptacle (20a, 125v) at 18" aff, uon, type as indicated on drawings ... at 18" aff, uon e-1 e-1 double duplex receptacle (20a, ... 1500 lumen output and

1200 AMP BUS AT 208/120V, 3PH, 4WBRACE FOR 100,000 AMPS SYMMETRICAL FAULTCURRENT. BREAKERS ARE 65,000 KAIC FRONT-ACCESS ONLY.

M

#3/0 GROUNDIN 1 1/2" CONDUIT.

D

E 4 #2 (Cu)

4 # 8 Cu)

FEEDER SCHEDULEDESIGNATION CONDUCTORS CONDUIT

1"

1-1/4"

EQUIPMENTGROUND

#8 (Cu)

#8 (Cu)

ALL GROUNDING AND BONDING CONDUCTORS SHALL BECOPPER WHERE IN CONTACT WITH EARTH.

ALL GROUNDING AND BONDING SHALL BE COPPER FORALL FEEDERS SMALLER THAN #2.

EC SHALL VERIFY ALL LUG SIZES PRIOR TO ROUGH-IN.EQUIPMENT AND PANELBOARDS REQUIRING PARALLELFEEDERS SHALL BE FURNISHED WITH MULTIPLE LUGS.

3.)

1.)

4.) COORDINATE SECONDARY TERMINATIONS AT UTILITYTRANSFORMER TO SWTCH BAORD WITH PENELEC ANDAHJ.

2.)

COPPER (Cu) ALUMINUM (AL)

EJ

PLAN NOTESX

CW

ATS (ETR)

J

PROVIDE ON CONCRETE PAD.

2

STAGEDIMMER

RACK

DN M

G60/3 AF60/3 AT

5KW120/208VGASGENERATORETR

GENERAL NOTES1. ALL NEW BRANCH CIRCUIT PANELS ARE 22 KAIC RATED, UON.

2. PRIOR TO INSTALLING NEW SWITCHBOARD. REVIEWINSTALLATION WITH POWER COMPANY AND AHJ ON EXACTLOCATION OF EQUIPMENT AND MEANS OF CONNECTION.

3. NEW WIRING AND CONDUIT SHOWN ON FEEDER SCHEDULEARE MINIMUM SIZES ALLOWABLE .

4. ALL WIRING ON ONE LINE DIAGRAM IS NEW TO REPLACEEXISTING WIRE.

J 4 #3/0 (Cu) #6 (Cu) 2"

PANELB-15

PANELP-110

PANELP-B01 PANEL

B-07

J

NEW

22

2

GENERATORPANEL

2

2

2

1. AT FIRST SECTION OF NEW SWITCHBOARD PROVIDE NEW 1 1/ 2"GRC CONDUIT TO NEW METER LOCATION AS COORDINATED WITHPOWER COMPANY IN MECHANICAL ROOM.

2. REWORK EXISTING FEEDER INTO NEW SWITCHBOARD. REMOVEEXISTING AND PROVIDE NEW WIRING COMPLETE TO NEW PANELLOCATION.

3. ON STAGE BACK WALL PROVIDE CONDUCTOR TAP IN NEWAUXILARY WIREWAY FOR FEEDS TO LOADS SHOWN .

4. PROVIDE FEED THROUGH OR DOUBLE LUGS.

5. PROVIDE NEW PANEL AND BACKBOX . NOTE IT IS PERMITTED TO PROVIDE NEW INTERIOR WITH CUSTOM BACK BOX. INTERIOR SHALL BE LISTED FOR INSTALLATION IN EXISTING BACK BOX DIMENSIONS.

6. PROVIDE NEW FEEDER , PANEL, AND BACK BOX FOR THIS PANEL.

7. EXISTING FEEDER TO REMAIN.

8. PROVIDE NEW FUSED DISCONNECT SWITCH TO REPLACE EXSITINGON BACK STAGE WALL.

PANELP-B02

N 4 #500 (Cu) #2 (Cu) 3"

M 4 # 500 (CU) # 2 (CU) 4"

NEWNEW

NEW

J

PANELP-308

NEW

2

ETRETR

400/

3

400/

3

200/

3

200/

3

90/3

100/

3

100/

3

60/3

(2) EXISTING 4" CONDUITS ROUTEDFROM PENELEC NETWORK INTOBUILDING POWER COMPANY TOPROVIDE NEW OPEN CABLING FROMSTREET SIDE CONDUIT INTO TOP OFNEW SERVICE SWITCH.

111

N

E

3

NEW

JH

STAGEDIMMER

RACK

EE

CENTRAL BUSINESS DISTRICTDISTRIBUTION AREA .POWER COMPANY TO PROVIDE NEW CABLING

1200

/3

COORDINATE SWITCH OVER AND PROVIDE TEMPORARY PROVIDE TEMPOARY POWER AND LIGHTING AS REQUIRED.

F=17,700

NEW

L

PANELP-101

NEW

E J

PANELP-10144 5 5

5

125/

3

125/

3

RTU-2RTU-1

EQEQ

50/3

HP-1

EQ

EQ REFERENCE EQUIPMENT CONNECTION SCHEDULEAND VERIFY FINAL LOAD WITH EQUIPMENTPROVIDER .

77

M

M

8

2

SH

EE

T S

IZE

24x

36 J

:\201

6\16

7076

\DE

LIV

ER

AB

LES

\DR

AW

ING

S\A

CA

D\E

rie P

layh

ouse

HV

AC

Sys

tem

Rep

lace

men

t\She

ets\

Ele

ctric

al\E

-801

ELE

CTR

ICA

L O

NE

-LIN

E D

IAG

RA

M.d

wg

SA

VE

D: C

CA

RLS

ON

201

7-05

-09

13:5

3 P

LOT:

201

7-05

-09

17:1

2

REVISION

PROJECT NO.DATE

NO. DATE

ER

IE, P

A 1

6506

4509

WE

ST

RID

GE

RO

AD

13 W

ES

T 10

TH S

TRE

ET

814-

836-

8500

ER

IE, P

EN

NS

YLV

AN

IA 1

6501

9 MAY 20171407

STA

GE

and

RE

STR

OO

M R

EN

OV

ATI

ON

S

©

©

E 801

ELECTRICAL ONE-LINEDIAGRAM