Designer™ SeriesTechnical/Product Information
IMPORTANT NOTICE
READ THIS MANUAL COMPLETELY PRIOR TO BEGINNING THE INSTALLATION OF THE Designer™ Series WALL SYSTEM. MBCI DETAILS MUST BE FOLLOWED AS A MINIMUM TO INSURE APPROPRIATE WARRANTIES WILL BE ISSUED.
ALWAYS INSPECT EACH AND EVERY PANEL AND ALL ACCESSORIES BEFORE INSTALLATION. NEVER INSTALL ANY PRODUCT IF ITS QUALITY IS IN QUESTION. NOTIFY MBCI IMMEDIATELY IF ANY PRODUCT IS BELIEVED TO BE OUT OF TOLERANCE OR HAS BEEN DAMAGED DURING SHIPMENT.
IF THERE IS A CONFLICT BETWEEN APPROVED ERECTION DRAWINGS PROVIDED OR APPROVED BY MBCI AND THE DETAILS IN THIS MANUAL, THE PROJECT ERECTION DRAWINGS WILL TAKE PRECEDENCE.
Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort to refine and improve products, MBCI reserves the right to discontinue products at any time or change specifications and/or designs without incurring obligation. To ensure you have the latest information available, please inquire or visit our website at www.mbci.com. Application details are for illustration purposes only and may not be appropriate for all environmental conditions, building designs or panel profiles. Projects should be designed to conform to applicable building codes, regulations and accepted industry practices. If there is a conflict between this manual and project erection drawings, the erection drawings will take precedence.
©Copyright NCI Group, Inc. All Rights Reserved. 11-2011
For complete performance specifications, product limitations, and disclaimers, please consult MBCI’s Paint and Galvalume Plus® war-ranties. Upon receipt of payment in full, these warranties are available upon request for all painted or Galvalume Plus® prime products. Sample copies can be found at www.mbci.com or contact your local MBCI Sales Representative.
The Engineering data contained herein is for the expressed use of customers and design professionals. Along with this data, it is recom-mended that the design professional have a copy of the most current version of the North American Specification for the Design of Cold-Formed Steel Structural Members published by the American Iron and Steel Institute to facilitate design. This Specification contains the design criteria for cold-formed steel components. Along with the Specification, the designer should reference the most current building code applicable to the project jobsite in order to determine environmental loads. If further information or guidance regarding cold-formed design practices is desired, please contact the manufacturer.
TABLE OF CONTENTS
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-1
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
ROOFING SYSTEM Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-2 General Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DS-3 - DS-4 Architect/Engineer Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-5
SPECIFICATIONS Specifications For Metal Wall Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DS-6 - DS-8
GENERAL INFORMATION Product Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DS-9 - DS-10
DESIGN Panel Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DS-11
Door Framing Details Typical Door Header/Jamb Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-12 Jamb Cleat Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-13 Header Cleat Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-14 Insulation Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-15 Spacer Zee Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-16 Panel Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-17 Cap Trim Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-18 Header/Jamb Trim Miter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-19
Window Framing Details Typical Window Header/Sill Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-20 Typical Window Jamb Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-21 Jamb Cleat Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-22 Header Cleat Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-23 Spacer Zee Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-24 Panel Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-25 Cap Trim Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-26 Header/Jamb Trim Miter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-27
Typical Inside Corner Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-28 Typical Outside Corner Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DS-29
GENERAL INFORMATION Designer™ Series
DS-2 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
INSTALLATION GUIDELINES
I. Pre-Order A. Prior to ordering panels, all dimensions should be confirmed by field measurements.
II. Jobsite Storage and Handling A. Check the shipment against the shipping list. B. Damaged material must be noted on Bill of Lading. C. Panels should be handled carefully. A spreader bar of appropriate length is recom-
mended for hoisting. D. Check to see that moisture has not formed inside the bundles during shipment. If
moisture is present, panels should be wiped dry, then restacked and loosely covered so that air can circulate between the panels.
III. Application Checklist A. Check substructure for proper alignment and uniformity to avoid panel distortion. B. Periodic check of panel alignment is crucial to proper panel installation. C. When installing panels over blanket insulation, it may be necessary to push middle
of panel in as clips and fasteners are installed to maintain a consistent flat surface along the wall.
D. Keep panels clean during installation. Do not allow panels to come into contact with or water runoff from lead, copper, or graphite.
Designer™ Series WALL SYSTEM
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-3
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
Coverage Width - 12"
Panel Attachment - See page DS-11
Panel Substrate - Galvalume Plus®
Panel Finish - Smooth or Embossed
Gauge - 24 & 22
PRODUCT SELECTION CHART
*See architectural color chart for available colors. ● - Available in any quantity ■ - Minimum quantity may be required.
Galvalume Plus® Signature® 300* Signature® 200*
24 gauge ● ■ ■ ■
22 gauge ● ■ ■ ■
1³⁄₄”
12”
GENERAL DESCRIPTION12" FLAT
NOTICEContact MBCI for Positive and Negative Wind Load information.
Signature® 300*Metallic
WALL SYSTEM Designer™ Series
DS-4 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
Coverage Width - 16"
Panel Attachment - See page DS-11
Panel Substrate - Galvalume Plus®
Panel Finish - Smooth or Embossed
Gauge - 24 & 22
PRODUCT SELECTION CHART
*See architectural color chart for available colors. ● - Available in any quantity ■ - Minimum quantity may be required.
Galvalume Plus® Signature® 300* Signature® 200*
24 gauge ● ● ● ●
22 gauge ■ ■ ■ ■
1³⁄₄”
16”
³⁄₈”
GENERAL DESCRIPTION16" FLUTED
NOTICEContact MBCI for Positive and Negative Wind Load information.
Signature® 300*Metallic
Designer™ Series WALL SYSTEM
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-5
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
ARCHITECT/ENGINEER INFORMATION
1. Designer™ Series is a concealed fastener wall panel designed to be used as either a retrofit wall panel or in new construction.
2. The Designer™ Series panels are offered in two profiles and sizes: 12" Flat Panel and 16" Fluted Panel.
3. Wall girts to which the Designer™ Series panels are to be attached must be properly aligned to prevent oil canning of the panels.
4. Heavier gauges and embossing minimizes oil canning. Industry standard - 24 gauge material. Oil canning is not a cause for rejection.
5. For continuous runs over 40', please inquire.
6. Caution for new construction - the Designer™ Series panel does not provide diaphragm capabili-ties.
SPECIFICATIONS Designer™ Series
DS-6 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
Metal Wall Systems
Specifier: Notation (#) means that text following is a specifi-er's note or sample.
PART 1 - GENERAL1.01 DESCRIPTION# Specifier: Do not alter paragraph A except by adding section title in brackets. A. General: 1. Furnish all labor, material, tools, equipment and
services for all preformed [# choose one: walls, fascia] as indicated, in accord with provisions of Contract Documents.
2. Completely coordinate with work of all other trades. 3. Although such work is not specifically indicated,
furnish and install all supplementary or miscella-neous items, appurtenances and devices incidental to or necessary for a sound, secure and complete installation.
4. See Division 1 for General Requirements. B. Related work specified elsewhere: 1. Structural steel: Section 05100. 2. Steel joists: Section 05200 or 05400. 3. Flashing and sheet metal: Section 07600.# Specifier: Delete references to sections not used and add any references which become pertinent.
1.02 QUALITY ASSURANCE A. Applicable standards: 1. SMACNA: "Architectural Sheet Metal Manual"
Sheet Metal and Air Conditioning Contractors National Association, Inc.
2. AISC: "Steel Construction Manual" American Institute of Steel Construction.
3. AISI: "Cold Form Steel Design Manual," American Iron and Steel Institute.
4. ASTM A792-83-AZ50: Specifications for steel sheet, aluminum-zinc alloy coated (galvanized) by the hot dip process, general requirements (Galvalume®).
B. Manufacturer's qualifications: 1. Manufacturer has a minimum of three years experi-
ence in manufacturing metal wall systems of this nature. Panels specified in this section shall be produced in a factory environment (not job site roll formed) with fixed-base roll forming equipment assuring the highest level of quality control. A let-ter from the manufacturer certifying compliance will accompany the product material submittals.
C. Installation contractor's qualifications: 1. Installation contractor shall meet the following mini-
mum criteria: a. Maintain $250,000 minimum general liability
insurance coverage. b. Maintain statutory limits of worker's compensa-
tion coverage as mandated by law. c. Have no viable claims pending regarding neg-
ligent acts or defective workmanship on previ-ously performed of current projects.
d. Have not filed for protection from creditors under any state or federal insolvency or debtor relief statutes or codes.
e. Provide five references from five different archi-tects or building owners for projects that have been in service for a minimum of two years, stating satisfactory performance by the installa-tion contractor.
f. Provide certification letter that installation con tractor has a minimum of three years of metal product installation experience immediately preceding the date upon which work is to com- mence. 1.03 SUBMITTALS A. Shop drawings: 1. Submit complete shop drawings and erection
details, approved by the general contractor's third party metal wall consultant, to the architect (owner) for review. Do not proceed with manufacture prior to review of shop drawings. Do not use drawings prepared by the architect (owner) for shop or erec-tion drawings.
2. Shop drawings show methods of erection, eleva-tions and plans of roof and wall panels, sections and details, anticipated loads, flashings, sealants, interfaces with all materials not supplied and pro-posed identification of component parts and their finishes.
B. Samples: 1. Submit samples and color chips for all proposed
finishes. a. Submit one 8 inch long sample of panel. b. Submit two 3 inch x 5 inch color chip samples
in color selected by the architect (owner). C. Warranty(s): 1. Metal wall system manufacturer, upon final accep-
tance for project, furnish a warranty covering bare metal against rupture, structural failure and perfora-tion due to normal atmospheric corrosion exposure for a period of 20 years.
2. Covering paint finish against cracking, checking, blistering, peeling, flaking, chipping, chalking and fading for a period of [# choose one: twenty-five
Designer™ Series SPECIFICATIONS
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-7
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
(25) years for wall panels (premium thermoset sili-cone polyester) or twenty-five (25) years for wall panels (premium fluorocarbon coating produced with Kynar 500 or Hylar 5000 resin)].
D. Metal wall system fabrication certification: 1. Submit a letter from the metal wall system
manufacturer certifying the Designer™ Series wall panels have been produced in a factory environ-ment (not job site roll formed) with fixed-base roll forming equipment.
E. Installation contractor's qualifications: 1. Submit proof that the installer of the metal wall
system has met all of the criteria outlined in "1.02 C. Installer's qualifications.”
2. Submit five references from five different architects or building owners for projects that have been in service for a minimum of two years, stating satis-factory performance by the installation contractor.
1.04 PRODUCT DELIVERY, STORAGE AND HANDLING A. Delivery: 1. Deliver metal wall system to job site properly pack-
aged to provide protection against transportation damage.
B. Handling: 1. Exercise extreme care in unloading, storing and
erecting metal wall system to prevent bending, warping, twisting and surface damage.
C. Storage: 1. Store all material and accessories above ground on
well skidded platforms and under waterproof cover-ing. Provide proper ventilation of metal wall system to prevent condensation build-up between each panel or trim/flashing component.
PART 2 - PRODUCTS [# Designer™ Series; for walls, fascia; new construction or retrofit]
2.01 MATERIALS A. Metal roof system profile: [# choose one] 1. 13⁄4 inch deep x 16 inch wide with 3⁄8 inch deep
fluting. 2. 13⁄4 inch deep x 12 inch wide with flat face. B. Metal wall system style: 1. Fluted face or flat face. 2. Concealed fastener. C. Gauge: [# choose one] 1. 22 gauge. 2. 24 gauge. D. Substrate: 1. Galvalume® steel sheet, 0.5 ounces. square foot,
minimum yield 50,000 PSI. E. Texture: [# choose one] 1. Smooth.
2. Embossed (reduces oil canning effect). F. Finish: [# choose one] 1. Premium thermoset silicone polyester (25 year
warranty). 2. Premium fluorocarbon coating produced with Kynar
500 or Hylar 5000 resin (25 year warranty). 3. Bare Galvalume® (20 year warranty). G. Color: 1. Selected from metal wall system manufacturer's
standard offering. H. Acceptable manufacturer: 1. MBCI - Houston, TX - (281) 445-8555. I. Optional manufacturers: 1. Butler Manufacturing - Kansas City, MO.# Insert: Architect's (owner's) method of approval of "or equals". J. Other manufacturers desiring approval, comply with
Section 01630
2.02 FABRICATION A. Material shall be in-line tension leveled prior to roll
forming finished panel profile. B. Roll form panels in continuous lengths, full length of
detailed runs. C. Standard panel length shall be no more than 40 feet
long (for longer length availability, contact manufacturer). D. Fabricate trim/flashing and accessories to detailed
profiles. E. Fabricate trim/flashing from same material as panel.
PART 3 - EXECUTION3.01 SURFACE CONDITIONS A. Examination: 1. Inspect installed work of other trades and verify
that such work is complete to a point where this work may continue.
2. Verify that installation may be made in accordance with approved shop drawings and manufacturer's instructions.
B. Discrepancies: 1. In event of discrepancy, notify the architect (owner). 2. Do not proceed with installation until discrepancies
have been resolved.
3.02 INSTALLATION A. Install metal wall system so that it is weathertight, with-
out waves, warps, buckles, fastening stresses or distor-tion, allowing for expansion and contraction.
B. Install metal wall system in accordance with manufac-turer's instructions and shop drawings.
C. Provide concealed anchors at all panel attachment locations.
D. Install panels plumb, level and straight with seams and ribs parallel, conforming to design as indicated.
SPECIFICATIONS Designer™ Series
DS-8 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
3.03 CLEANING, PROTECTION A. Dispose of excess materials and remove debris
from site. B. Clean work in accordance with manufacturer's recom-
mendations. C. Protect work against damage until final acceptance.
Replace or repair to the satisfaction of the architect (owner), any work that becomes damaged prior to final acceptance.
D. Touch up minor scratches and abrasions.
END OF SECTIONDISCLAIMER: MBCI makes no warranty, express or implied, as to the merchantability or fitness for any particular purpose of any product manufactured by an optional manufacturer. If you choose to use a product manufactured by an optional manufacturer, as defined herein, you take the product as is and at your own risk. Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. MBCI reserves the right to discontinue products at any time or change specifications and/or designs without notice and without incurring obligation.
To insure you have the latest information available, please inquire.
Designer™ Series GENERAL INFORMATION
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-9
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
PRODUCT CHECKLISTDesigner™ Series 12" Flat Panel
Head/Jamb Cleat Two Piece Head Trim
Outside Corner Inside Corner Base Trim
1³⁄₈”
1”
1”
3”
2¹⁄₄”
⁵⁄₈”
T-5251T-5241 T-6307
T-6301 T-6305
1³⁄₄”
12”
3¹⁄₂”
3¹⁄₂”
3¹⁄₂”
3¹⁄₂”
□ □ □
□ □
□ □
Designer™ Series 16" Fluted Panel
1³⁄₄”
16”
³⁄₈”
Spacer Zee
T-6246 □Two Piece Jamb Trim
T-6303 □
¹⁄₂”
1”
1”
2¹⁄₄”
¹⁄₂”
2”
T-6301
3³⁄₄”
¹⁄₂”
1¹⁄₂”¹⁄₂”
Support Zee
T-6309 □
Sill Trim
FL-848 □
1¹⁄₂”
4”
1³⁄₄”
2¹⁄₄”
⁵⁄₈”
T-6301
To be used with T-6301
To be used with T-6301
To be used with T-6303 or T-6305
GENERAL INFORMATION Designer™ Series
DS-10 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
PRODUCT CHECKLIST
Outside Closure
Fastener #4A Fastener #14A
HW-540HW-4037
□ □
□ □
Urethane Sealant
Fastener #4 Fastener #14 Fastener #17
□ □ □
Designer™ Series DESIGN
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-11
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
PANEL ATTACHMENT
NOTES: 1. Install Fastener #4A horizontally through the seams of the Designer™ Series panels at each point in which the panel is fastened to the substructure.
FASTENER LOCATION
WALL GIRT
FASTENER #172 PER CONN.
FASTENER #172 PER CONN.
FASTENER #172 PER CONN.
FASTENER #172 PER CONN.
FASTENER #4A@ EACH CONN.
FASTENER #4A@ EACH CONN.
FASTENER #17@ 5’-0” O.C.
Designer™ Series PANEL
WALL GIRT
EAVE STRUT
Designer™ Series PANEL
BASE TRIM[T-6307]
CONC. FLOOR
BASE ANGLE
SECTION ‘A’ - ‘A’
A
A
Designer™ Series PANEL
DESIGN Designer™ Series
DS-12 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
DOOR FRAMING DETAILSTYPICAL DOOR HEADER/JAMB DETAILS
FINISH IN LOW SECTION AT JAMB
TWO PIECE JAMB TRIM [T-6303]
DOOR JAMB FASTENER #17 @ 12” O.C.
SUPPORT ZEE[T-6309]
HEAD/JAMB CLEAT [T-6301]
TWO PIECE HEAD TRIM [T-6305] (SNAP ONTO CLEAT)
DOOR HEADER
GIRT
SECTION AT HEAD
(FINISHED IN HIGH)
FASTENER #17 @ 5’-0” O.C.
Designer™ Series PANEL
Designer™ Series PANEL
FASTENER #17 @ 5’-0” O. C.
FASTENER #17 @ 5’-0” O. C.
GIRT
PANEL DROP
PANEL DROP FASTENER #14
Designer™ Series PANEL
Designer™ Series PANEL
DOOR JAMB
@ 12” O.C.
FASTENER #14@ 12” O.C.
DOUBLE FACED TAPE
HEAD/JAMB CLEAT [T-6301]
NOTE: INSULATION NOT SHOWN FOR CLARITY.
TWO PIECE JAMB TRIM [T-6303] (SNAP ONTO CLEAT)
HEAD/JAMBCLEAT [T-6301]
FASTENER #172 PER CONN.
FASTENER #172 PER CONN.
Designer™ Series DESIGN
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-13
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
DOOR FRAMING DETAILSJamb Cleat Installation
GIRT
BASE ANGLE
FASTENER #17 @ 5’-0” O.C.
FASTENER #17 @ 2’-0” O.C.
DOUBLE FACED TAPE
DOUBLE FACED TAPE
DOOR FRAMING
BASE TRIM [T-6307]
HEAD/JAMB CLEAT [T-6301] (NOTCH FOR HEAD CLEAT)
NOTCH TRIMAND BEND FLAT
HEAD/JAMB CLEAT[T-6301]
INSULATIONSTOP
NOTES: 1. Notch top of jamb cleat for header cleat to be attached on top. 2. Attach Header/Jamb Cleat to door jamb with Fastener #17 @ 2'-0" o.c. Header/Jamb Cleat must continue to bottom of wall. 3. Apply Double Faced Tape to Header/Jamb Cleat. Place tape to "Insulation Stop".
DESIGN Designer™ Series
DS-14 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
DOOR FRAMING DETAILSHeader Cleat Installation
GIRT
DOOR FRAMING
BASE ANGLE
FASTENER #17 @ 5’-0” O.C.
FASTENER #17 @ 2’-0” O.C.
DOUBLE FACED TAPE
BASE TRIM [T-6307]
HEAD/JAMB CLEAT [T-6301] (NOTCH FOR JAMB CLEAT)
HEAD/JAMB CLEAT [T-6301]
DOUBLE FACED TAPE
DOUBLE FACED TAPE
NOTCH TRIMAND BEND FLAT
HEAD/JAMB CLEAT[T-6301]
HEAD/JAMB CLEAT[T-6301]
INSULATIONSTOP
NOTES: 1. Notch header cleat to fit into trough of jamb cleat. 2. Attach header cleat to door header with Fastener #17 @ 2'-0" o.c. 3. Apply Double Faced Tape to header cleat. Place tape to "Insulation Stop".
Designer™ Series DESIGN
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-15
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
DOOR FRAMING DETAILSInsulation Installation
BASE ANGLE
FASTENER #17@ 5’-0” O.C.
INSULATION
DOUBLE FACEDTAPE
NOTE:HOLD BACKINSULATION1” FROM BASETRIM BOTTOM
BASE TRIM[T-6307]
HEAD/JAMBCLEAT [T-6301] GIRT
NOTES: 1. Install insulation around door opening. Cut insulation at "Insulation Stop" on Header/Jamb Cleat.
DESIGN Designer™ Series
DS-16 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
DOOR FRAMING DETAILSSpacer Zee Installation
BASE ANGLE
FASTENER #17 @ 5’-0” O.C.
FASTENER #17 (3 PER SUPPORT ZEE)
INSULATION
NOTE: HOLD BACK INSULATION 1” FROM BASE TRIM BOTTOM
BASE TRIM [T-6307]
SUPPORT ZEE [T-6309](FINISHING IN LOW)OR PANEL DROP(FINISHING IN HIGH)
GIRT
NOTES: 1. Attach Support Zee, when finishing in the low, with Fastener #17 @ 3 per piece. Panel Drop will be used when finishing in the high flute.
Designer™ Series DESIGN
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-17
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
DOOR FRAMING DETAILSPanel Installation
BASE ANGLE
FASTENER #17 @ 5’-0” O.C.
INSULATION
FASTENER #172 PER CONN.
FASTENER #172 PER CONN.
NOTE:HOLD BACKINSULATION1” FROM BASETRIM BOTTOM
BASE TRIM[T-6307]
Designer™ SeriesPANEL
GIRT
NOTES: 1. Stitch panel side laps with Fastener #4A at each support.
DESIGN Designer™ Series
DS-18 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
DOOR FRAMING DETAILSCap Trim Installation
BASE ANGLE
FASTENER #17@ 5’-0” O.C.
INSULATION
TWO PIECE HEAD TRIM [T-6305](SNAP ONTO CLEAT)
NOTE:HOLD BACKINSULATION1” FROM BASETRIM BOTTOM
NOTE: REFER TO PAGE DS-19FOR TRIM MITER INSTRUCTIONS
Designer™ SeriesPANEL
GIRT
TWO PIECEJAMB TRIM [T-6303](SNAP ONTO CLEAT)
TWO PIECEJAMB TRIM [T-6303](SNAP ONTO CLEAT)
BASE TRIM[T-6307]
NOTES: 1. Cut and notch tabs to bend down on Header Cap. Snap Header Cap onto cleat. 2. Cut Jamb Cap to length. Snap Jamb Cap onto cleat.
Designer™ Series DESIGN
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-19
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
DOOR FRAMING DETAILSHEADER/JAMB TRIM MITER
URETHANESEALANT
NOTCH TRIMAND BEND OVER
TWO PIECE JAMB TRIM[T-6303] (SNAP ONTOHEAD/JAMB CLEAT)
TWO PIECEJAMB TRIM[T-6303]
HEAD/JAMBCLEAT [T-6301]
HEAD/JAMB CLEAT[T-6301]
HEAD/JAMB CLEAT[T-6301]
HEAD/JAMBCLEAT [T-6301]
TWO PIECEHEAD TRIM [T-6305](SNAP ONTOHEAD/JAMB CLEAT)
TWO PIECEHEAD TRIM [T-6305]
DESIGN Designer™ Series
DS-20 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
WINDOW FRAMING DETAILSTYPICAL WINDOW HEADER/SILL DETAILS
SECTION AT SILL
SECTION AT HEAD
TWO PIECE HEAD TRIM [T-6305] (SNAP ONTO CLEAT)
SILL TRIM [FL-848]
FRAMED OPENING TRIM (OPTIONAL)
FRAMED OPENING TRIM (OPTIONAL)
WINDOW FRAMING
WINDOW
HEAD/JAMB CLEAT[T-6301]
Designer™ Series PANEL
Designer™ Series PANEL
URETHANE SEALANT
FASTENER #17 @ 5’-0” O.C.
FASTENER #14A@ 5’-0” O.C.
WINDOW FRAMING
NOTE: INSULATION NOT SHOWN FOR CLARITY.
FASTENER #172 PER CONN.
FASTENER #172 PER CONN.
Designer™ Series DESIGN
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-21
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
WINDOW FRAMING DETAILSTYPICAL WINDOW JAMB DETAILS
SECTION AT JAMB
WINDOW TWO PIECE JAMB TRIM [T-6303] (SNAP ONTO CLEAT)
WINDOW FRAMING
FRAMED OPENING TRIM (OPTIONAL)
PANEL DROP
PANEL DROP
FASTENER #14 @ 12” O.C.
Designer™ Series PANEL
Designer™ Series PANEL
FASTENER #17 @ 5’-0” O.C.
HEAD/JAMB CLEAT [T-6301]
FINISH IN LOW
TWO PIECE JAMB TRIM [T-6303]
WINDOW JAMB FASTENER #17 @ 12” O.C.
SUPPORT ZEE[T-6309]
FASTENER #17 @ 5’-0” O.C.
Designer™ Series PANEL
HEAD/JAMB CLEAT [T-6301] NOTE:
INSULATION NOT SHOWN FOR CLARITY.
GIRT
FASTENER #172 PER CONN.
FASTENER #172 PER CONN.
FASTENER #14@ 12” O.C.
DESIGN Designer™ Series
DS-22 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
WINDOW FRAMING DETAILSJamb Cleat Installation
GIRT
BASE ANGLE
FASTENER #17 @ 5’-0” O.C.
FASTENER #17 @ 2’-0” O.C.
INSULATION
WINDOW FRAMING (FRAMED OPENING TRIM OPTIONAL)
NOTE: HOLD BACK INSULATION 1” FROM BASE TRIM BOTTOM
BASE TRIM [T-6307]
HEAD/JAMB CLEAT [T-6301] (NOTCH FOR HEAD CLEAT)
NOTCH TRIMAND BEND FLAT
HEAD/JAMB CLEAT[T-6301]
NOTES: 1. Cut insulation out from window opening. 2. Notch top of jamb cleat for header cleat to be attached on top. 3. Attach Header/Jamb Cleat to window jamb with Fastener #17 @ 2'-0" o.c. Header/Jamb Cleat must continue to bottom of wall.
Designer™ Series DESIGN
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-23
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
WINDOW FRAMING DETAILSHeader Cleat Installation
GIRT
BASE ANGLE
FASTENER #17 @ 5’-0” O.C.
FASTENER #17 @ 2’-0” O.C.
INSULATION
NOTE: HOLD BACK INSULATION 1” FROM BASE TRIM BOTTOM
BASE TRIM [T-6307]
HEAD/JAMB CLEAT [T-6301] (NOTCH FOR JAMB CLEAT)
NOTCH TRIMAND BEND FLAT
HEAD/JAMB CLEAT[T6301]
HEAD/JAMB CLEAT[T-6301]
NOTES: 1. Notch header cleat to fit into trough of jamb cleat. 2. Attach header cleat to window header with Fastener #17 @ 2'-0" o.c.
DESIGN Designer™ Series
DS-24 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
WINDOW FRAMING DETAILSSpacer Zee Installation
GIRT
BASE ANGLE
FASTENER #17 @ 5’-0” O.C.
FASTENER #17 (2 PER SUPPORT ZEE)
INSULATION
NOTE: HOLD BACK INSULATION 1” FROM BASE TRIM BOTTOM
BASE TRIM [T-6307]
SUPPORT ZEE [T-6309](FINISHING IN LOW)OR PANEL DROP(FINISHING IN HIGH)
NOTES: 1. Attach support zee, when finishing in the low, with Fastener #17 @ 2 per piece. Panel Drop will be used when finishing in the high flute.
Designer™ Series DESIGN
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-25
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
WINDOW FRAMING DETAILSPanel Installation
GIRT
BASE ANGLE
FASTENER #17 @ 5’-0” O.C.
INSULATION
NOTE:HOLD BACKINSULATION1” FROM BASETRIM BOTTOM
BASE TRIM[T-6307]
Designer™ SeriesPANEL
FASTENER #172 PER CONN.
FASTENER #172 PER CONN.
NOTES: 1. Stitch panel side laps with Fastener #4A at each support.
DESIGN Designer™ Series
DS-26 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
WINDOW FRAMING DETAILSCap Trim Installation
GIRT
BASE ANGLE
FASTENER #17 @ 5’-0” O.C.
INSULATION
TWO PIECE HEAD TRIM [T-6305] (SNAP ONTO CLEAT)
TWO PIECE JAMB TRIM [T-6303] (SNAP ONTO CLEAT)
TWO PIECE JAMB TRIM [T-6303] (SNAP ONTO CLEAT)
SILL TRIM [FL-848]
NOTE:HOLD BACKINSULATION1” FROM BASETRIM BOTTOM
BASE TRIM[T-6307]
Designer™ Series PANEL
NOTE: REFER TO PAGE DS-27FOR TRIM MITER INSTRUCTIONS
NOTES: 1. Cut and notch tabs to bend down on Header Cap. Snap Header Cap onto cleat. 2. Cut and notch tabs on Sill Trim to bend up behind Jamb Cap. Attach Sill Trim with Fastener #14. 3. Cut and notch Jamb Cap allowing notch to cover Sill Trim. Snap Jamb Cap onto cleat.
Designer™ Series DESIGN
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-27
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
WINDOW FRAMING DETAILSHEADER/JAMB TRIM MITER
URETHANESEALANTNOTCH TRIM
AND BEND OVER
TWO PIECE JAMB TRIM[T-6303] (SNAP ONTOHEAD/JAMB CLEAT)
TWO PIECEJAMB TRIM[T-6303]HEAD/JAMB
CLEAT [T-6301]
HEAD/JAMB CLEAT[T-6301] HEAD/JAMB CLEAT
[T-6301]
HEAD/JAMBCLEAT [T-6301]
TWO PIECEHEAD TRIM [T-6305](SNAP ONTOHEAD/JAMB CLEAT)
TWO PIECEHEAD TRIM [T-6305]
DESIGN Designer™ Series
DS-28 SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
TYPICAL INSIDE CORNER DETAIL
NOTES: 1. Attach panel drop to structure with a Fastener #17 at each girt. 2. Field cut last panel as required and attach to panel drop with Fastener #14 at 2'-0" o.c. 3. Attach Inside Corner Trim to panel with Fastener #14 at 2'-0" o.c.
STRUCTURE (NOT BY MBCI)
INSIDE CORNER TRIM [T-5251]
SUPPORT ZEE[T-6309]
INSIDE CORNER TRIM [T-5251]
PANEL DROP
SPACER ZEE [T-6246]
FINISHING IN LOW
FINISHING IN HIGH
FASTENER #17 (AT EACH GIRT)
FASTENER #17(AT EACH GIRT)
FASTENER #14 @ 2’-0” O.C.
FASTENER #14 @ 2’-0” O.C.
FASTENER #14 @ 2’-0” O.C.
Designer™ SeriesPANEL
Designer™ Series PANEL
Designer™ Series PANEL
FASTENER #172 PER CONN.
FASTENER #172 PER CONN.
FASTENER #4A@ EACH CONN.
Designer™ Series DESIGN
SUBJECT TO CHANGE WITHOUT NOTICE SEE www.mbci.com FOR CURRENT INFORMATION EFFECTIVE NOVEMBER 1, 2011 DS-29
Houston, TX 877/713-6224Adel, GA 888/446-6224Atlanta, GA 877/512-6224Atwater, CA 800/829-9324Dallas, TX 800/653-6224Indianapolis, IN 800/735-6224
Jackson, MS 800/622-4136Lubbock, TX 800/758-6224Memphis, TN 800/206-6224Oklahoma City, OK 800/597-6224Omaha, NE 800/458-6224Phoenix, AZ 888/533-6224
Richmond, VA 800/729-6224Rome, NY 800/559-6224Salt Lake City, UT 800/874-2404San Antonio, TX 800/598-6224
FINISHING IN LOW
FINISHING IN HIGH
STRUCTURE(NOT BY MBCI)
OUTSIDE CORNER TRIM [T-5241]
SUPPORT ZEE[T-6309]
OUTSIDE CORNER TRIM [T-5241]
PANEL DROP
SPACER ZEE [T-6246]
FASTENER #17 (AT EACH GIRT)
FASTENER #17 (AT EACH GIRT)
FASTENER #14 @ 2’-0” O.C.
FASTENER #14 @ 2’-0” O.C.
FASTENER #14 @ 2’-0” O.C.
Designer™ Series PANEL
Designer™ Series PANEL
Designer™ Series PANEL
FASTENER #172 PER CONN.
FASTENER #172 PER CONN.
FASTENER #4A@ EACH CONN.
NOTES: 1. Attach panel drop to structure with a Fastener #17 at each girt. 2. If required, attach spacer zee to panel with a Fastener #14 at 2'-0" o.c. 3. Attach Outside Corner Trim to wall panel with Fastener #14 at 2'-0" o.c.
TYPICAL OUTSIDE CORNER DETAIL
For the most current information available, visit our Web site at www.mbci.comHouston, TX14031 West HardyP.O. Box 38217Houston, TX 77238877/713-6224
Adel, GA1601 Rogers RoadP.O. Box 1107Adel, GA 31620888/446-6224
Atlanta, GA2280 Monier AvenueP.O. Box 44729Atlanta, GA 30336877/512-6224
Atwater, CA550 Industry WayP.O. Box 793Atwater, CA 95301800/829-9324
Dallas, TX1804 Jack McKay Blvd.P.O. Box 1210Ennis, TX 75120800/653-6224
Indianapolis, IN1780 McCall Drive P.O. Box 657Shelbyville, IN 46176800/735-6224
Jackson, MS201 Apache DriveP.O. Box 720100Jackson, MS 39272800/622-4136
Lubbock, TX5711 East FM-40P.O. Box 10133Lubbock, TX 79408800/758-6224
Memphis, TN300 Highway 51 NorthP.O. Box 366Hernando, MS 38632800/206-6224
Oklahoma City, OK7000 S. Eastern AvenueP.O. Box 95998Oklahoma City, OK 73143800/597-6224
Omaha, NE1011 Ellison AvenueOmaha, NE 68110800/458-6224
Phoenix, AZ660 South 91st AvenueP.O. Box 739Tolleson, AZ 85353888/533-6224
Richmond, VA 1703 Ruffin Mill RoadP.O. Box 239Colonial Heights, VA 23834800/729-6224
Rome, NY6168 State Route 233P.O. Box 4141Rome, NY 13442800/559-6224
Salt Lake City, UT1155 West 2300 NorthP.O. Box 16027Salt Lake City, UT 84116800/874-2404
San Antonio, TX8677 I-10 EastP.O. Box 69Converse, TX 78109800/598-6224
Litho in U.S.A. 11-2011