Data Sheet for Energy Efficient Construction
Date Customer Name Customer Phone # Job Site Address City Zip Avg. Ceiling Height
Builder Name . Builder Phone # . HVAC Dealer . Living Area Sq. Ft. . Home Orientation N S E W NE NW SE SW New Construction Addition
For the ultimate in comfort and low operational cost, Gulf Power recommends the construction of an EarthCents Home. See the other side of this form for details
Please circle or check the features to be installed.
1) Double Pane Windows: Vinyl Wood Metal Clear Low E: U-Value_______ SHGC________2) Gasket Weather-Stripped Exterior Doors: Metal Wood Fiberglass 3) Wall Insulation: R-19 R-4) Ceiling Insulation: Batts or Blown R-38 R-30
Blown Foam applied to the underside of the roof decking _________ R-Value _________ 5) Exterior Finish: Brick Stucco Vinyl Other _________ 6) Roof Color/Type: Dark or Light Shingle Metal Tile Avg. Roof Pitch ___________ 7) Slab: Off grade (R-19) ________8) Duct System: Conditioned Space Unconditioned Space 9) Lighting: ______% of Incandescent ______% of Fluorescent and/or CFL 10) Water Heating: Electric Yes No # of units ______ Gals./ea. ______ Where Located ______________ Water Heating Options: Heat recovery Unit* ______ Heat Pump Water Heater* ______ Solar Water Heater* ______
*Minimum 50 gallon hot water tank, hot water lines must be insulated
Heating & Cooling Information
The remainder of this form will be completed by Gulf Power and returned to you. Thank you. Notice: The following heat loss/heat gain calculation(s) is/are provided to assist the HVAC Contractor in properly sizing the heating and cooling equipment based on Northwest Florida Design Conditions (Summer: 95˚F Outdoor / 75˚F Indoor / 63˚F WB; Winter: 29˚F Outdoor / 70˚F Indoor) Do not size HVAC to meet ARI Design Conditions. HVAC Contractors should select equipment that, at a minimum, meets the sensible and latent load calculations below.
Air changes per hour:
Calculated Loads: 1st Floor / Zone 1 2nd Floor / Zone 2 3rd Floor / Zone 3
Heat Gain Sensible ______________BTUH _______________BTUH ______________BTUH Heat Gain Latent ______________BTUH _______________BTUH ______________BTUH
Total Cooling Load ______________BTUH _______________BTUH ______________BTUH
Total Heating Load ______________BTUH _______________BTUH ______________BTUH
Residential Energy Consultant Telephone # Date . Copy 1 /Builder or HVAC Dealer Copy 2 /Gulf Power
300670 (01/16)
EARTHCENTS HOME QUALIFICATIONS Single Family / Multi-Family / New / Existing
Minimum Required Features
OR
OR
**HVAC SIZING CRITERIA - Units must be sized according to the
latest editions of ACCA “Manual J”, ASHRAE Handbook of
Fundamentals, or an equivalent load calculation procedure; in
addition to the appropriate HVAC Equipment Manufacturers
Specifications. Equipment performance must be no less than
calculated cooling sensible and latent loads @ local design
conditions, and not more than 15% over calculated loads. In
specifying equipment, the next available size may be used. In addi-
tion, indoor and outdoor coils shall be matched in accordance
with ARI standards.
Minimum Required Performance Testing
≤
OR
OR
≤ ≤
OR
OR
OR
Additional Energy Efficiency Recommendations
Blown-in fiberglass Blown-in Cellulose
Blown-in expandable foam