dampers - ac - heinen & hopman · dampers - ac. dampers there are different types of dampers:...

6
> Ventilation Air Conditioning Refrigeration Heating 22 º C Inside OUTSIDE HUMIDITY PROVIDED BY HEINEN & HOPMAN 35 C 90% PRODUCTS Dampers - AC

Upload: others

Post on 06-Oct-2020

25 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Dampers - AC - Heinen & Hopman · dampers - Ac. dampers There are different types of dampers: • Fire and smoke dampers • Air control and shut-off dampers Fire and smoke dampers

>

Ventilation Air Conditioning RefrigerationHeating

22ºCInside

OUTSIDEHUMIDITY

PROVIDED BYHEINEN & HOPMAN

35 C

90%

productsdampers - Ac

Page 2: Dampers - AC - Heinen & Hopman · dampers - Ac. dampers There are different types of dampers: • Fire and smoke dampers • Air control and shut-off dampers Fire and smoke dampers

dampers

There are different types of dampers:• Fire and smoke dampers• Air control and shut-off dampers

Fire and smoke dampers Fire and smoke dampers prevent the spread of fire and smoke between fire zones, where people must have the maximum amount of time to react to possible fire. The dampers are type-approved according to A-0 (A-60).The A-60 marine fire and smoke damper complements the range of automatic fire and gas dampers and associated controls. The damper is the solution for shipboard air conditioning and ventilation systems fire safety engineering strategies.

ACFD A-60 fire and smoke dampers

Frame: AISI 316 stainless steel / galvanized steel.Thickness: 1.2, 2 or 3 mm.Blades: AISI 316 and AISI 430 options.Sizes: 100x100 ~ 1000x1000 mm.Circular connection pieces: 100 ~ 1000 mm.

air control and shut-off dampers Air control and shut-off dampers control the airflow or shut off airflow in ductwork where tightness, thermal insulation and reliability are important. The dampers meet international standards for both rectangular and circular ducts and the leakage class is accordance with the EN1751 standards.

ACCS air control and shut-off balancing dampers

Frame: AISI 316 stainless steel / galvanized steel.Thickness: 1.5 mm.Blades: AISI 316 stainless steel.Sizes: 100x100 ~ 1200x1200 mm at 50 mm intervals.Operation system: electrical, pneumatic or manual.Double section modules possible.

Control The dampers can be controlled electrically, pneumatically or manually. In case of fire, the fire and gas dampers will close automatically.

The electrically and pneumatically controlled dampers are driven by an actuator.

Belimo actuator: standard actuatorSchischek actuator: actuator used in explosion-proof areas or if the actuator must open/close within 3 sec./90°C.

To offer complete

operational security to those who

ensure ours

“ “

Alternatives available on request.Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Page 3: Dampers - AC - Heinen & Hopman · dampers - Ac. dampers There are different types of dampers: • Fire and smoke dampers • Air control and shut-off dampers Fire and smoke dampers

Alternatives available on request.Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

marine fire dampersA-60 marine fire and smoke dampers are used in air conditioning and ventilation systems, in dry filtered air. The dampers have been tested and approved for fitting to class A-60 divisions (bulkheads and decks), when suitably insulated (refer to insulation details).The dampers can be used where the maximum system pressure is up to 1500 Pa and duct velocities are limited to 15m/s. Pay particular attention to the blade rivets, where crevice corrosion will cause rapid failure of blades if not kept in check.The dampers are suitable for vertical and horizontal applications, with airflow in either direction. The dampers are normally open and failsafe to the closed position.

The dampers have two casings and blade options:1. 430 Stainless steel blades, galvanized steel casing - only suitable for installation in dry filtered systems.2. 316 Stainless steel blades, casing and drive - more suited for corrosive conditions, but even this will rapidly corrode and fail if not properly maintained, when used in air intake systems at sea. The addition of a mist eliminator is highly recommended and access must be provided for maintenance.

• Type-approved class A-60 when suitably insulated.• Available as ATEX-approved.• Optional Silicon blade seals can be provided for low leakage requirement at ambient temperature.• Electrical Thermal Release (ETR) temperature 72 ºC or Pneumatic Thermal Release (PTR) with a failsafe 74 °C fusible link.• Low weight due to patented double skin blade structure.• Automatic electrical, pneumatic or spring operation system available.• Maximum duct pressure: 1500 Pa. Maximum air velocity: 15 m/s.

dimensions and material thicknessThe dampers meet international standards for both rectangular (width B 100-1000 mm and height H 100-1000 mm, 1 mm division) and circular ducts (Ø 100-1000 mm).

Part Material Finishing

Frame Stainless steel EN 1.4404 (AISI316L) / Galvanized steel -

Blades Stainless steel EN 1.4404 (AISI316L) -

Bearings Stainless steel EN 1.4404 (AISI316L) -

Shafts Stainless steel EN 1.4404 (AISI316L) -

Dimensions S mm

L mm

If B or H 100 till 1000 1.2 / 2 / 3 150

if Ø100 till Ø1000 1.2 / 2 / 3 230

Page 4: Dampers - AC - Heinen & Hopman · dampers - Ac. dampers There are different types of dampers: • Fire and smoke dampers • Air control and shut-off dampers Fire and smoke dampers

Alternatives available on request.Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

Page 5: Dampers - AC - Heinen & Hopman · dampers - Ac. dampers There are different types of dampers: • Fire and smoke dampers • Air control and shut-off dampers Fire and smoke dampers

Alternatives available on request.Due to continuous product development, Heinen & Hopman reserves the right to introduce alterations without prior notice.

aCCs air control and shut-off dampers

• Low closed blade leakage performance.• Temperature operation range up to +180 °C.• Maximum duct pressure: 1000 Pa. Maximum air velocity: 10 m/s.• Low close blade leakage to EN 1751 class 2 requirements.

Part Material Note

Casing Galvanized steel Stainless steel AISI316L also available

Blades Galvanized steel Silicon blade seal, suitable for 280OC

Blade gaskets Silicon Heat-proof model: LTE silicon

Duct gasket Rubber compound Circular connections

Bearings Synthetic / stainless-steel blade bearings Self-lubricated heat-proof model: stainless steel AISI316L

Drive shaft Galvanized steel Rectangular bar (15x15 mm)

W H

200 - 1200 200 - 1200

ØD WxH

200 - 1000 200 x 1000

Dimensions in mm

Page 6: Dampers - AC - Heinen & Hopman · dampers - Ac. dampers There are different types of dampers: • Fire and smoke dampers • Air control and shut-off dampers Fire and smoke dampers

www.heinenhopman.com

Heinen & Hopman encourages a more

sustainable world. By providing eco-friendly solutions and serviceswe offer our clients

the option of reducing energy consumption

and thus co2 emissions. Visit

greenmanifest.info for more information.

BrazilT: +5521 3587 4241/4244E: [email protected]

France - La CiotatT: +334 4204 8685E: [email protected]

France - GrasseT: +336 3090 7786 E: [email protected]

GermanyT:+49 4073 1680E: [email protected]

IndiaT: +9133 6499 1293E: [email protected]

ItalyT: +3901 8745 7970E: [email protected]

The Netherlands (HQ)T: +313 3299 2500E: [email protected]

The Netherlands (rotterdam)T: +317 8890 8050E: [email protected]

NorwayT: +47 6919 0900E: [email protected]

peoples republic of ChinaT: +8621 3253 2896E: [email protected]

peoples republic of ChinaT: +86 510 8528 1763E: [email protected]

polandT: +489 1433 1800E: [email protected]

romaniaT: +402 3644 8222E: [email protected]

russiaT: +7 (4012) 308 801E: [email protected]

singaporeT: +65 6897 7879E: [email protected]

south KoreaT: +8270 4901 0000E: [email protected]

spainT: +349 3225 9668E: [email protected]

swedenT: +46 3121 7500E: [email protected]

TurkeyT: +9021 6493 8118E: [email protected]

Uae (abu dhabi) T:+971 2550 4147E: [email protected]

Uae (dubai)T: +971 4263 5453E: [email protected]

Usa - Fort Lauderdale, FloridaT: +195 4463 0110E: [email protected]