control cabinet · seifert has nearly 50 years’ experience and expertise within the industrial...

36
Control Cabinet Accessories

Upload: others

Post on 01-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

Control CabinetAccessories

Page 2: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

Page

Produc t Overv iew 03

Cab ine t Heaters 06 - 09

F i l te r Fans 10 - 30

Accessor ies F i l te r Fans 31

Thermosta t / Hygros ta t 32 - 34

Thermal Management So lu t ions 35

Table of Content

Subject to technical changes.

Page 3: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

Type Features Rated voltage Approval Page

Heating power Control cabinet heaters

KH 801 125 W • • • • CE, cULus 7

KH 801 200 W • • • • CE, cULus 8

KH 801 400 W • • CE, cULus 9

KH 801 800 W • • CE, cULus 9

Max. Air volume flow Filter and Filter fansFF 4000 / 4000E Outlet filter CE, cURus 11

FL 4010 A 12 m3/h • • CE, cURus 13

FL 4010 D 16 m3/h • • CE, cURus 14

FL 4023 A 22 m3/h • • CE, cURus 15

FL 4023 D 50 m3/h • CE, cURus 16

FL 4210 A 67 m3/h • • CE, cURus 17

FL 4210 D 47 m3/h • • CE, cURus 18

FL 4220 A 45 m3/h • • CE, cURus 19

FL 4411 A 110 m3/h • • CE, cURus 20

FL 4411 D 100 m3/h • CE, UR 21

FL 4421 A 100 m3/h • • CE, cURus 22

FL 4610 D 225 m3/h • • CE, UR 23

FL 4611 D 140 m3/h • • CE, UR 24

FL 4620 A 230 m3/h • • CE, cURus 25

FL 4621 A 105 m3/h • • CE, cURus 26

FL 4830 A 520 - 610 m3/h • • • CE, cURus 27

FL 4880 A 618 - 820 m3/h • • • • CE, cURus 28

FL 6050 A 500 m3/h • • CE, cURus 29

FL 6060 A 420 m3/h • • CE, cURus 29

FL 6070 A 420 m3/h • • CE, cURus 30

Thermostats / HygrostatsST 3980 Thermostat (NC) • • CE, cURus 32

ST 3981 Thermostat (NO) • • CE, cURus 32

ST 3990 Change over Thermostat • CE 32

ST 3982 Twin Thermostat • • CE 33

ST 3991 Change over Hygrostat • • CE 34

230 V

400 V

24 V

12 V

120 V

460 V

48 V

Page 4: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

Leonardo da Vinc i

The I t a l i an pa in te r, scu lp to r, a r ch i t ec t and sc ien t i s t i s cons ide red to be a un i ve rsa l gen ius , whose wo rk i n a r t , ph i l osophy and sc ience a re comb ined i n a un ique way.

He was the c rea to r o f many o f the g rea tes t mas terp ieces o f pa in t ing , such as “ the las t Supper ” and the “Mona L isa” .

A la rge number o f des igns fo r bu i ld ings , mach inery, works o f a r ts and scu lp tu res , found no rea l i za t ion dur ing h is l i fe t ime.

Do ing and knowing were equa l l y impor tan t to h im. He drew h is s t reng th f rom pa in t ing , wh ich he descr ibed as the queen o f a l l sc iences . Leonardo da Vinc i conduc ted w i th h is var ious researches and inven t ions o f the la te Rena issance a lso the sc ien t i f i c and tech-n ica l p rogress in to the ear ly modern t imes .

The work o f Leonardo i s the resu l t o f a un ique combina t ion o f sc ien t i f i c research and ar t i s t i c c rea t i v i t y. Through h is p ioneer ing s tud ies o f mechan ics and hydrau l i cs Leonardo da Vinc i inven ted a var ie ty o f new mach ines . H is ana tomica l research con t r ibu ted to a new image o f human i ty.

Leonardo da Vinc i was we l l ahead o f h is t imes , and many o f h is in feas ib le look ing inven-t ions were ac tua l l y rea l i zed cen tu r ies la te r.

Page 5: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

Your par tner fo r p ro fess iona l Thermal Management

S e i f e r t v e n t i l a t e s , c o o l s , d e h u m i d i f i e s , h e a t s , c o n t r o l s a n d i l l u m i n a t e s c o n t r o l c a b i n e t s f o r t h e i n d u s t r y, te lecom-mun ica t ion and med ica l sec to r as we l l as fo r cha l leng ing env i ronments l i ke the food p rocess ing and car manufac tu r -ing indus t ry.

Se i fe r t has near ly 50 years ’ exper ience and exper t i se w i th in the indus t r ia l therma l management . Ex t reme requ i re -ments l i ke in ou tdoor, m i l i ta ry app l i ca t ions and cus tomized produc ts fund a re reso lved in p ro fess iona l and t ime ly manner.

Wi th innova t ive techno logy s ta r t ing w i th a comprehens ive var ie ty o f h igh per fo rmance f i l te r fans and heat exchangers , power fu l coo l ing un i ts to complex ch i l l e r so lu t ions , we supp ly to our s teady g rowing cus tomer base a l l over the wor ld .

Our accessor ies program inc ludes cabinet heaters , thermostats and hygrostats . An innovat ive range of energy eff ic ient cabinet l ight ing complements our accessory por t fo l io .

Wi th companies in Germany, Mal ta , Swi tzer land, USA and Austra l ia and a g lobal network of agents and serv ice par tners, Sei fer t is wel l represented in most indust r ia l countr ies.

Our main object ive is to maintain our leading market posi t ion for thermal management of control cabinets, by constant ly improving ourselves and our products. New product developments combined with competence in product ion and service are sett ing the standards which gives the best possible benef i ts to our customers.

The new Sol iTherm Indoor cool ing uni ts o f the ComPact ser ies, the f i l ter less Sl imLine ser ies and the ext reme compact Pel t ier ser ies are set t ing new standards in terms of re l iab i l i ty, pr ice-per formance rat io and running costs .

L ike Leonardo Da Vinc i ’s v is ions our s logan “wegweisend innovat iv” combines v is ion and responsib i l i ty for everyth ing we are doing.

Page 6: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

6 www.seifertsystems.com

Cabine t hea te rs Cab ine t hea te rs a re an impo r tan t segmen t o f t he Se i f e r t cab ine t accesso r i es p rog ram and fo rm pa r t o f ou r t he rma l managemen t so lu t i ons .

Tempera tu re d i f fe rences in cab ine ts , mos t ly in ou tdoor app l i ca t ions , o f ten resu l t in humid i ty and condensat ion wh ich may cause func t ion fa i lu res and cor ros ion . The use o f the appropr ia te hea t ing un i t fo r your cab ine t w i l l e l im ina te these p rob lems. Fan heaters d is t r ibu te the in te rna l warm a i r equa l l y th roughout the con t ro l cab ine t . Fur ther advantage o f fan hea ters compared to PTC heaters i s the much lower s ta r t ing cur ren t .

Se i fe r t fan hea ters have the fo l low ing fea tu res :

- Auto - se t t ing : The in -bu i l t thermosta t jo in t l y ad jus ts bo th fan and heater.

- Fan ON – se t t ing : The fan keeps runn ing con t inuous ly and the thermosta t sw i tches on and o f f the hea ter depend ing on the tempera tu r se t t ings .

The range o f the tempera tu re se t t ing o f the thermosta t shows bo th ce ls ius and fahrenhe i t va lues .When used in combina t ion w i th a hygros ta t the fea tu res o f our fan hea te rs can be fu r ther exp lo i ted .Our p roduc t range inc ludes power fu l fans w i th hea t ing capac i ty rang ing , f rom 125 W up to 800 W.

Page 7: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

7 www.seifertsystems.com

KH 801 Fan Heater series

KH 801

Type KH 801 125W 230V

KH 801 125W 115V

KH 801 125W 24V

KH 801 125W 48V

Part-no. 801125A44000 801125A33000 801125D22001 801125D11001

PERFORMANCE DATA

Power output @ 10ºC 125 W

Fan air flow 27 m3/h

Operating temp. range -20ºC...+40ºC / -4ºF...+104ºF -10ºC...+40ºC / 14ºF...+104ºF

HOUSING / DIMENSIONS

Dimensions (H x W x D) 137 mm x 111 mm x 116 mm

Weight 0.8 kg

ELECTRICAL DATA

Voltage / frequency 230 VAC@ 50 / 60Hz

115 VAC@ 50 / 60Hz 24 VDC 48 VDC

Rated current 0.7 A 1.2 A 5.3 A 2.7 A

Fuse rating 2 A (T) 6 A (T) 3 A (T)

FEATURES

Cable length Connection terminals

Certification CE, cULus CE, cULus pending

Optional: 35mm DIN Rail (EN 50022) Part-no. SP-KH801-AK-1

Page 8: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

8 www.seifertsystems.com

KH 801 Fan Heater series

KH 801

Type KH 801 200W 230V

KH 801 200W 115V

KH 801 200W 24V

KH 801 200W 48V

Part-no. 801200A440000 801200A33000 801200D22001 801200D11001

PERFORMANCE DATA

Power output @ 10ºC 200 W

Fan air flow 27 m3/h

Operating temp. range -20ºC...+40ºC / -4ºF...+104ºF -10ºC...+40ºC / 14ºF...+104ºF

HOUSING / DIMENSIONS

Dimensions (H x W x D) 137 mm x 111 mm x 116 mm

Weight 0.8 kg

ELECTRICAL DATA

Voltage / frequency 230 VAC@ 50 / 60Hz

115 VAC@ 50 / 60Hz 24 VDC 48 VDC

Rated current 1.0 A 1.9 A 8.4 A 4.3 A

Fuse rating 2 A (T) 3 A (T) 10 A (T) 5 A (T)

FEATURES

Connection Connection terminals

Certification CE, cULus CE, cULus pending

Optional: 35mm DIN Rail (EN 50022) Part-no. SP-KH801-AK-1

Page 9: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

9 www.seifertsystems.com

KH 801 Fan Heater series

KH 801

Type KH 801 400W 230V

KH 801 400W 115V

KH 801 800W 230V

KH 801 800W 115V

Part-no. 801400A44000 801400A33000 801800A44000 801800A33000

PERFORMANCE DATA

Power output @ 10ºC 400 W 800 W

Fan air flow 44 m3/h

Operating temp. range -20ºC...+40ºC / -4ºF...+104ºF

HOUSING / DIMENSIONS

Dimensions (H x W x D) 190 mm x 111 mm x 116 mm

Weight 0.8 kg

ELECTRICAL DATA

Voltage / frequency 230 VAC@ 50 / 60Hz

115 VAC@ 50 / 60Hz

230 VAC@ 50 / 60Hz

115 VAC@ 50 / 60Hz

Rated current 1.9 A 3.6 A

Fuse rating 3 A (T) 5 A (T)

FEATURES

Connection Connection terminals

Certification CE, cULus

Optional: 35mm DIN Rail (EN 50022) Part-no. SP-KH801-AK-1

Page 10: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

10 www.seifertsystems.com

Rapid ins ta l la t ionMount ing w i thou t sc rews, jus t by s imp lypress ing i t on to the enc losure cu tou t .

Opera t iona l sa fe tyReplacement o f the f i l te r f rom the ou ts ide ,w i thou t too ls .

S l ide open ingCover f i xed to and re leased f rom basev ia s l id ing ca tches .

EMC compl ianceEMC mode ls ava i lab le .

Page 11: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

11 www.seifertsystems.com

FF 4000 Outlet filter series

FF 4000

Type FF 4000 000 FF 4000 100 FF 4000 200 FF 4000 300 FF 4000 400

Part-no. 400000000 400010000 400020000 400030000 400040000

Part-no. EMV Version 400000000E 400010000E 400020000E 400030000E 400040000E

Dimensions (H x W x D) 106.5 x 106,5 x 23.2 mm

150 x 150 x 29.2 mm

203.9 x 203.9 x 29.5 mm

250 x 250 x 33.8 mm

325 x 325 x 34 mm

Cut out dimensions 92.5 x 92.5 mm (+0.5)

125 x 125 mm (+1.5)

177 x 177 mm (+1.5)

223 x 223 mm (+1.5)

291 x 291 mm (+1.5)

Material housing ABS-Plastic

Weight 0.07 kg 0.18 kg 0.26 kg 0.42 kg 0.60 kg

Degree of separation 85% - DIN 24185

Cabinet wall thickness 1 - 2.5 mm 1 - 2.1 mm 1.5 - 2.5 mm

Filtering class G3 according to EN 779

Installation Elastic clips or by 4 self-threading screws

Operating temp. range -10ºC - +55ºC

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 12: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

12 www.seifertsystems.com

Fi l te r FansFi l te r fans a re used i f the des i red cab ine t tempera tu re can be cons tan t l y above the ambien t a i r tempera tu re .

In combina t ion w i th thermosta ts f rom Se i fe r t you can save on energy s ince the fan i s on ly on when ac tua l l y needed, on mater ia l because less consumpt ion o f f i l te r mats and on t ime s ince less c lean ing i s requ i red . A l l th is w i l l ensure a longer l i fe t ime o f the f i l te r fans and w i l l enhance your p rocess re l iab i l i t y and sa fe ty.

A l l our f i l te r fans a re a lso ava i lab le as EMC vers ions .

Spec ia l fea tu res o f our f i l te r fans a re

- no too ls requ i red fo r ins ta l la t ion- sh ie lded and se l f - lubr ica t ing ba l l bear ing fans - permanent sea l ing gaske t in po lyure thane foam - f i l te r med ia can be c leaned, up to 10 t imes by wash ing , b low ing d ry and l igh t l y bea t ing- op t iona l f i x ing w i th sc rews (w i th EMC vers ions f i x ing w i th sc rews is mandatory )

Pre fe rab ly use the f i l te r fan to b low the coo l ambien t a i r in to enc losure (F ig .2 .and F ig .3 ) . This ensures that a sl ight posi t ive pressure bui lds up inside the cabinet and that only f i l tered air f lows inside i t . The a i r b lown in to the cab ine t d isp laces the warm a i r wh ich ex i ts th rough the exhaus t f i l te r. I f however a i r i s d rawn ou t o f the cab ine t by suc t ion power (F ig .1 ) on ly f i l te red ambien t a i r shou ld en te r the cab ine t . Ensure tha t no un f i l te red a i r can en te r th rough poor sea ls o r cab le en t r ies .

I f you insta l l a combinat ion of f i l ter fan/exhaust f i l ter, the f i l ter fan should a lways be p laced in the lower th i rd of the cabinet and the exhaust f i l ter should be in the upper par t o f the cabinet to prevent heat pockets ins ide.

F ig .1 Exhaus t Sys tem F ig .2 Pressure & Exhaus t Sys tem F ig .3 Pressure Sys tem

Page 13: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

13 www.seifertsystems.com

FL 4010A Filter fan series

FL 4010A 115V / 230V

Type FL 4010A 230V

FL 4010A 230V-R

FL 4010A 115V

FL 4010A 115V-R

Part-no. 4010A4000 4010A4100 4010A3000 4010A3100

Part-no. EMC version 4010A4000E 4010A4100E 4010A3000E 4010A3100E

PERFORMANCE DATA

Max. airflow 12 m3/h @ 50 Hz15 m3/h @ 60 Hz

16 m3/h @ 50 Hz21 m3/h @ 60 Hz

12 m3/h @ 50 Hz15 m3/h @ 60 Hz

16 m3/h @ 50 Hz21 m3/h @ 60 Hz

Static pressure 23 Pa @ 50 Hz33 Pa @ 60 Hz

45 Pa @ 50 Hz64 Pa @ 60 Hz

23 Pa @ 50 Hz33 Pa @ 60 Hz

45 Pa @ 50 Hz64 Pa @ 60 Hz

Noise level 31 dB(A) @ 50 Hz33 dB(A) @ 60 Hz

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 106.5 x 106.5 x 66.6 mm

Cut out dimensions 92.5 x 92.5 mm (+0.5)

Material housing ABS-Plastic

Weight 0.39 kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60Hz 115V 50/60Hz

Rated current 0.062 A @ 50 Hz0.050 A @ 60 Hz

0.063 A @ 50 Hz0.052 A @ 60 Hz

0.113 A @ 50 Hz0.092 A @ 60 Hz

0.111 A @ 50 Hz0.093 A @ 60 Hz

Power consumption 10 W @ 50 Hz 8 W @ 60 Hz

9 W @ 50 Hz7 W @ 60 Hz

9 W @ 50 Hz7.5 W @ 60 Hz

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1 - 2 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 14: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

14 www.seifertsystems.com

FL 4010D Filter fan series

FL 4010D 12V / 24V

Type FL 4010D 12V

FL 4010D 12V-R

FL 4010D 24V

FL 4010D 24V-R

Part-no. 4010D1000 4010D1100 4010D2000 4010D2100

Part-no. EMC version 4010D1000E 4010D1100E 4010D2000E 4010D2100E

PERFORMANCE DATA

Max. airflow 16 m3/h 23 m3/h 16 m3/h 23 m3/h

Static pressure 28 Pa 44 Pa 28 Pa 44 Pa

Noise level 30 dB(A)

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 106.5 x 106.5 x 53.6 mm

Cut out dimensions 92.5 x 92.5 mm (+0.5)

Material housing ABS-Plastic

Weight 0.35 kg

ELECTRICAL DATA

Voltage / frequency 12V DC 24V DC

Rated current 0.17 A 0.184 A 0.085 A 0.092 A

Power consumption 2.0 W 2.2 W 2.0 W 2.2 W

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1 - 2.1 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 15: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

15 www.seifertsystems.com

FL 4023A Filter fan series

FL 4023A

Type FL 4023A 230V FL 4023A 115V

Part-no. 4023A4000 4023A3000

Part-no. EMCversion 4023A4000E 4023A3000E

PERFORMANCE DATA

Max. airflow 22 m3/h @ 50 Hz26 m3/h @ 60 Hz

22 m3/h @ 50 Hz26 m3/h @ 60 Hz

Static pressure 41 Pa @ 50 Hz 57 Pa @ 60 Hz

41 Pa @ 50 Hz 57 Pa @ 60 Hz

Noise level 37 dB(A) @ 50 Hz42 dB(A) @ 60 Hz

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 106.5 x 106.5 x 79.5 mm

Cut out dimensions 92.5 x 92.5 mm (+0.5)

Material housing ABS-Plastic

Weight 0.54 kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60Hz 115V 50/60Hz

Rated current 0.078 A @ 50 Hz0.068 A @ 60 Hz

0.145 A @ 50 Hz0.127 A @ 60 Hz

Power consumption 12 W @ 50 Hz11 W @ 60 Hz

12 W @ 50 Hz10 W @ 60 Hz

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1 - 2 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 16: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

16 www.seifertsystems.com

FL 4023D Filter fan series

FL 4023D 24V

Type FL 4023D 24V FL 4023D 24V-R

Part-no. 4023D2000 4023D2100

Part-no. EMC version 4023D2000E 4023D2100E

PERFORMANCE DATA

Max. airflow 50 m3/h 60 m3/h

Static pressure 160 Pa 200 Pa

Noise level 59 dB(A)

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 106.5 x 106.5 x 77.1 mm

Cut out dimensions 92.5 x 92.5 mm (+0.5)

Material housing ABS-Plastic

Weight 0.35 kg

ELECTRICAL DATA

Voltage / frequency 24V DC

Rated current 0.61 A 0.71 A

Power consumption 15 W 17 W

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1.5 - 2.2 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 17: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

17 www.seifertsystems.com

FL 4210A Filter fan series

FL 4210A 115V / 230V

Type FL 4210A 230V

FL 4210A 230V-R

FL 4210A 115V

FL 4210A 115V-R

Part-no. 4210A4000 4210A4100 4210A3000 4210A3100

Part-no. EMC version 4210A4000E 4210A4100E 4210A3000E 4210A3100E

PERFORMANCE DATA

Max. airflow 67 m3/h @ 50 Hz79 m3/h @ 60 Hz

60 m3/h @ 50 Hz70 m3/h @ 60 Hz

67 m3/h @ 50 Hz79 m3/h @ 60 Hz

60 m3/h @ 50 Hz70 m3/h @ 60 Hz

Static pressure 73 Pa @ 50 Hz86 Pa @ 60 Hz

86 Pa @ 50 Hz115 Pa @ 60 Hz

73 Pa @ 50 Hz86 Pa @ 60 Hz

86 Pa @ 50 Hz115 Pa @ 60 Hz

Noise level 40 dB(A) @ 50 Hz44 dB(A) @ 60 Hz

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 150 x 150 x 73 mm

Cut out dimensions 125 x 125 mm (+1.5)

Material housing ABS-Plastic

Weight 0.8 kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60Hz 115V 50/60Hz

Rated current 0.13 A @ 50 Hz0.10 A @ 60 Hz

0.252 A @ 50 Hz0.220 A @ 60 Hz

0.247 A @ 50 Hz0.220 A @ 60 Hz

Power consumption 18 W @ 50 Hz16 W @ 60 Hz

19 W @ 50 Hz17 W @ 60 Hz

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1 - 2.1 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 18: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

18 www.seifertsystems.com

FL 4210D Filter fan series

FL 4210D 24V / 48V

Type FL 4210D 24V

FL 4210D 24V-R

FL 4210D 48V

FL 4210D 48V-R

Part-no. 4210D2000 4210D2100 4210D7000 4210D7100

Part-no. EMCversion 4210D2000E 4210D2100E 4210D7000E 4210D7100E

PERFORMANCE DATA

Max. airflow 47 m3/h 64 m3/h 47 m3/h 64 m3/h

Static pressure 56 Pa 79 Pa 56 Pa 79 Pa

Noise level 48 dB(A)

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 150 x 150 x 73 mm

Cut out dimensions 125 x 125 mm (+1.5)

Material housing ABS-Plastic

Weight 0.5 kg

ELECTRICAL DATA

Voltage / frequency 24V DC 48V DC

Rated current 0.31 A 0.18 A

Power consumption 7.4 W 8.6 W

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1 - 2.1 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 19: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

19 www.seifertsystems.com

FL 4220A Filter fan series

FL 4220A 115V / 230V

Type FL 4220A 230V

FL 4220A230V-R

FL 4220A 115V

FL 4220A 115V-R

Part-no. 4220A4000 4220A4100 4220A3000 4220A3100

Part-no. EMC version 4220A4000E 4220A4100E 4220A3000E 4220A3100E

PERFORMANCE DATA

Max. airflow 45 m3/h @ 50 Hz50 m3/h @ 60 Hz

47 m3/h @ 50 Hz52 m3/h @ 60 Hz

45 m3/h @ 50 Hz 50 m3/h @ 60 Hz

47 m3/h @ 50 Hz 52 m3/h @ 60 Hz

Static pressure 55 Pa @ 50 Hz62 Pa @ 60 Hz

72 Pa @ 50 Hz82 Pa @ 60 Hz

55 Pa @ 50 Hz 62 Pa @ 60 Hz

72 Pa @ 50 Hz 82 Pa @ 60 Hz

Noise level 48 dB(A) @ 50 Hz54 dB(A) @ 60 Hz

46 dB(A) @ 50 Hz 49 dB(A) @ 60 Hz

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 150 x 150 x 73 mm

Cut out dimensions 125 x 125 mm (+0.5) 125 x 125 mm (+1.5)

Material housing ABS-Plastic

Weight 0.8 kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60Hz 115V 50/60Hz

Rated current 0.11 A @ 50 Hz0.10 A @ 60 Hz

0.20 A @ 50 Hz 0.18 A @ 60 Hz

0.11 A @ 50 Hz 0.10 A @ 60 Hz

Power consumption 18 W @ 50 Hz17 W @ 60 Hz

16 W @ 50 Hz 15 W @ 60 Hz

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1 - 2.1 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 20: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

20 www.seifertsystems.com

FL 4411A Filter fan series

FL 4411A 115V / 230V

Type FL 4411A 230V

FL 4411A 230V-R

FL 4411A 115V

FL 4411A 115V-R

Part-no. 4411A4000 4411A4100 4411A3000 4411A3100

Part-no. EMC version 4411A4000E 4411A4100E 4411A3000E 4411A3100E

PERFORMANCE DATA

Max. airflow 110 m3/h @ 50 Hz130 m3/h @ 60 Hz

110 m3/h @ 50 Hz135 m3/h @ 60 Hz

110 m3/h @ 50 Hz130 m3/h @ 60 Hz

110 m3/h @ 50 Hz135 m3/h @ 60 Hz

Static pressure 80 Pa @ 50 Hz100 Pa @ 60 Hz

100 Pa @ 50 Hz120 Pa @ 60 Hz

80 Pa @ 50 Hz100 Pa @ 60 Hz

100 Pa @ 50 Hz120 Pa @ 60 Hz

Noise level 40 dB(A) @ 50 Hz44 dB(A) @ 60 Hz

46 dB(A) @ 50 Hz 44 dB(A) @ 60 Hz

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 203.9 x 203.9 x 95.5 mm

Cut out dimensions 177 x 177 mm (+1.5)

Material housing ABS-Plastic

Weight 1.2 kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60Hz 115V 50/60Hz

Rated current 0.126 A @ 50 Hz0.110 A @ 60 Hz

0.128 A @ 50 Hz0.110 A @ 60 Hz

0.20 A @ 50 Hz0.18 A @ 60 Hz

0.257 A @ 50 Hz0.224 A @ 60 Hz

Power consumption 19 W @ 50 Hz17 W @ 60 Hz

19 W @ 50 Hz18 W @ 60 Hz

16 W @ 50 Hz15 W @ 60 Hz

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1 - 2.1 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 21: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

21 www.seifertsystems.com

FL 4411D Filter fan series

FL 4411D 24V

Type FL 4411D 24V FL 4411D 24V-R

Part-no. 4411D2000 4411D2100

Part-no. EMC version 4411D2000E 4411D2100E

PERFORMANCE DATA

Max. airflow 100 m3/h 120 m3/h

Static pressure 60 Pa 83 Pa

Noise level 42 dB(A)

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 203.9 x 203.9 x 95.5 mm

Cut out dimensions 177 x 177 mm (+1.5)

Material housing ABS-Plastic

Weight 0.9 kg

ELECTRICAL DATA

Voltage / frequency 24V DC

Rated current 0.342 A

Power consumption 8.2 W 8.5 W

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1 - 2.1 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, UR

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 22: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

22 www.seifertsystems.com

FL 4421A Filter fan series

FL 4421A 115V / 230V

Type FL 4421A 230V

FL 4421A 230V-R

FL 4421A 115V

FL 4421A 115V-R

Part-no. 4421A4000 4421A4100 4421A3000 4421A3100

Part-no. EMC version 4421A4000E 4421A4100E 4421A3000E 4421A3100E

PERFORMANCE DATA

Max. airflow 100 m3/h @ 50 Hz110 m3/h @ 60 Hz

Static pressure 55 Pa @ 50 Hz60 Pa @ 60 Hz

70 Pa @ 50 Hz80 Pa @ 60 Hz

55 Pa @ 50 Hz60 Pa @ 60 Hz

70 Pa @ 50 Hz80 Pa @ 60 Hz

Noise level 48 dB(A) @ 50 Hz54 dB(A) @ 60 Hz

46 dB(A) @ 50 Hz49 dB(A) @ 60 Hz

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 203.9 x 203.9 x 95.5 mm

Cut out dimensions 177 x 177 mm (+1.5)

Material housing ABS-Plastic

Weight 1.2 kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60Hz 115V 50/60Hz

Rated current 0.106 A @ 50 Hz0.100 A @ 60 Hz

0.213 A @ 50 Hz0.202 A @ 60 Hz

Power consumption 18 W @ 50 Hz18 W @ 60 Hz

19 W @ 50 Hz18 W @ 60 Hz

18 W @ 50 Hz18 W @ 60 Hz

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1 - 2.1 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 23: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

23 www.seifertsystems.com

FL 4610D Filter fan series

FL 4610D 24V / 48V

Type FL 4610D24V

FL 4610D 24V-R

FL 4610D 48V

FL 4610D 48V-R

Part-no. 4610D2000 4610D2100 4610D7000 4610D7100

Part-no. EMC version 4610D2000E 4610D2100E 4610D7000E 4610D7100E

PERFORMANCE DATA

Max. airflow 225 m3/h

Static pressure 99 Pa 140 Pa 99 Pa 140 Pa

Noise level 58 dB(A) 60 dB(A)

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 250 x 250 x 124.2 mm

Cut out dimensions 223 x 223 mm (+1.5)

Material housing ABS-Plastic

Weight 1.4 kg

ELECTRICAL DATA

Voltage / frequency 24V DC 48V DC

Rated current 0.71 A 0.34 A

Power consumption 17 W 16 W

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1.5 - 2.5 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, UR

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 24: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

24 www.seifertsystems.com

FL 4611D Filter fan series

FL 4611D 24V / 48V

Type FL 4611D24V

FL 4611D 24V-R

FL 4611D 48V

FL 4611D 48V-R

Part-no. 4611D2000 4611D2100 4611D7000 4611D7100

Part-no. EMC version 4611D2000E 4611D2100E 4611D7000E 4611D7100E

PERFORMANCE DATA

Max. airflow 140 m3/h 150 m3/h 140 m3/h 150 m3/h

Static pressure 63 Pa 84 Pa 63 Pa 84 Pa

Noise level 42 dB(A) 42.5 dB(A)

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 250 x 250 x 111.6 mm

Cut out dimensions 223 x 223 mm (+1.5)

Material housing ABS-Plastic

Weight 0.9 kg

ELECTRICAL DATA

Voltage / frequency 24V DC 48V DC

Rated current 0.32 A 0.18 A

Power consumption 7.6 W 8.6 W

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1.5 - 2.5 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, UR

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 25: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

25 www.seifertsystems.com

FL 4620A Filter fan series

FL 4620A 115V / 230V

Type FL 4620A 230V

FL 4620A 230V-R

FL 4620A 115V

FL 4620A 115V-R

Part-no. 4620A4000 4620A4100 4620A3000 4620A3100

Part-no. EMC version 4620A4000E 4620A4100E 4620A3000E 4620A3100E

PERFORMANCE DATA

Max. airflow 230 m3/h @ 50 Hz270 m3/h @ 60 Hz

245 m3/h @ 50 Hz290 m3/h @ 60 Hz

230 m3/h @ 50 Hz270 m3/h @ 60 Hz

245 m3/h @ 50 Hz290 m3/h @ 60 Hz

Static pressure 115 Pa @ 50 Hz155 Pa @ 60 Hz

165 Pa @ 50 Hz210 Pa @ 60 Hz

55 Pa @ 50 Hz60 Pa @ 60 Hz

70 Pa @ 50 Hz80 Pa @ 60 Hz

Noise level 50 dB(A) @ 50 Hz55 dB(A) @ 60 Hz

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 250 x 250 x 124.2 mm

Cut out dimensions 223 x 223 mm (+1.5)

Material housing ABS-Plastic

Weight 1.5 kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60Hz 115V 50/60Hz

Rated current 0.134 A @ 50 Hz0.160 A @ 60 Hz

0.135 A @ 50 Hz0.160 A @ 60 Hz

0.28 A @ 50 Hz0.27 A @ 60 Hz

0.28 A @ 50 Hz0.26 A @ 60 Hz

Power consumption 32 W @ 50 Hz36 W @ 60 Hz

31 W @ 50 Hz31 W @ 60 Hz

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1.5 - 2.5 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 26: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

26 www.seifertsystems.com

FL 4621A Filter fan series

FL 4621A 115V / 230V

Type FL 4621A 230V

FL 4621A 230V-R

FL 4621A 115V

FL 4621A 115V-R

Part-no. 4621A4000 4621A4100 4621A3000 4621A3100

Part-no. EMC version 4621A4000E 4621A4100E 4621A3000E 4621A3100E

PERFORMANCE DATA

Max. airflow 105 m3/h @ 50 Hz120 m3/h @ 60 Hz

110 m3/h @ 50 Hz120 m3/h @ 60 Hz

105 m3/h @ 50 Hz120 m3/h @ 60 Hz

110 m3/h @ 50 Hz120 m3/h @ 60 Hz

Static pressure 54 Pa @ 50 Hz57 Pa @ 60 Hz

66 Pa @ 50 Hz70 Pa @ 60 Hz

54 Pa @ 50 Hz57 Pa @ 60 Hz

66 Pa @ 50 Hz70 Pa @ 60 Hz

Noise level 48 dB(A) @ 50 Hz54 dB(A) @ 60 Hz

46 dB(A) @ 50 Hz49 dB(A) @ 60 Hz

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 250 x 250 x 111.8 mm

Cut out dimensions 223 x 223 mm (+1.5)

Material housing ABS-Plastic

Weight 1.2 kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60Hz 115V 50/60Hz

Rated current 0.11 A @ 50 Hz0.10 A @ 60 Hz

0.21 A @ 50 Hz0.21 A @ 60 Hz

Power consumption 18 W @ 50 Hz17 W @ 60 Hz

17 W @ 50 Hz16 W @ 60 Hz

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1.5 - 2.5 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours and IP 55 available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 27: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

27 www.seifertsystems.com

FL 4830A Filter fan series

FL 4830A 120V - 460V

Type FL 4830A230V

FL 4830A 230V-R

FL 4830A120V

FL 4830A 120V-R

FL 4830A400V

Part-no. 4830A4000 4830A4100 4830A3000 4830A3100 4830A9000

Part-no. EMC version 4830A4000E 4830A4100E 4830A3000E 4830A3100E 4830A9000E

PERFORMANCE DATA

Max. airflow 50Hz60Hz

520 m3/h580 m3/h

550 m3/h610 m3/h

520 m3/h580 m3/h

550 m3/h610 m3/h

540 m3/h-

Static pressure 50Hz60Hz

160 Pa190 Pa

180 Pa195 Pa

160 Pa190 Pa

180 Pa195 Pa

180 Pa-

Noise level 50Hz60Hz

65.3 dB(A)68.1 dB(A)

66 dB(A)69.2 dB(A)

69.8 dB(A)72.7 dB(A)

Operating temp. range -10ºC - +55ºC -10ºC - +70ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 325 x 325 x 160.2 mm

Cut out dimensions 291 x 291mm (+1.5)

Material housing ABS-Plastic

Weight 3.1kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60 Hz 120V 50/60 Hz 400V 3N~ 50/60 Hz

Rated current 50Hz60Hz

0.31A0.35A

0.366A0.407A

0.68A0.73A

0.252A-

Power consumption

50Hz60Hz

70 W85 W

74 W83 W

169 W-

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1.5 - 2.5 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours and IP 55 available on request. Q = Air flow [m3/h]P = Static pressure [Pa]

Page 28: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

28 www.seifertsystems.com

FL 4880A Filter fan series

FL 4880A 120V - 460V

Type FL 4880A 230V

FL 4880A 230V-R

FL 4880A 120V

FL 4880A 120V-R

FL 4880A 400V

FL 4880A400V-R

Part-no. 4880A4000 4880A4100 4880A3000 4880A3100 4880A9000 4880A9100

Part-no. EMCversion 4880A4000E 4880A4100E 4880A3000E 4880A3100E 4880A9000E 4880A9100E

PERFORMANCE DATA

Max. airflow 50Hz60Hz

670 m3/h760 m3/h

720 m3/h820 m3/h

670 m3/h760 m3/h

740 m3/h840 m3/h

618 m3/h690 m3/h

648 m3/h674 m3/h

Static pressure 50Hz60Hz

210 Pa220 Pa

290 Pa280 Pa

210 Pa220 Pa

315 Pa320 Pa

245 Pa290 Pa

375 Pa450 Pa

Noise level 50Hz60Hz

66.0 dB(A)69.2 dB(A)

67.6 dB(A)70.6 dB(A)

74.7 dB(A)78.9 dB(A)

69 dB(A) @ 50 Hz72 dB(A) @ 60 Hz

Operating temp. range -10ºC - +55ºC -10ºC - +70ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 325 x 325 x 158.5 mm

Cut out dimensions 291 x 291mm (+1.5)

Material housing ABS-Plastic

Weight 4.25 kg 3.7 kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60 Hz 120V 50/60 Hz 400 - 460V 50/60 Hz

Rated current 50Hz60Hz

0.53A0.69A

1.18A1.46A

1.16A1.49A

0.10A0.12A

0.10A0.12A

Power consumption

50Hz60Hz

120 W158 W

120 W157 W

124 W146 W

125 W171 W

70 W85 W

FEATURES

Installation Elastic clips or by 4 self-threading screws

Cabinet wall thickness 1.5 - 2.5 mm

Filtering class G3 according to EN 779

Degree of separation 85% - DIN 24185

IP protection to IEC 60 529 IP 54

Certification CE, cURus

Optional: Different housing colours and IP 55 available on request. Q = Air flow [m3/h]P = Static pressure [Pa]

Page 29: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

29 www.seifertsystems.com

FL 6050A / 6060A Top Mount Filter fan series

FL 6050A / 6060A

Type FL 6050A 230V

FL 6050A 115V

FL 6060A 230V

FL 6060A 115V

Part-no. 6050A4000 6050A3000 6060A4000 6060A3000

Part-no. EMC version 6050A4000E 6050A3000E 6060A4000E 6060A3000E

PERFORMANCE DATA

Max. airflow 500 m3/h @ 50 Hz575 m3/h @ 60 Hz 575 m3/h 420 m3/h @ 50 Hz

490 m3/h @ 60 Hz 490 m3/h

Static pressure 335 Pa @ 50 Hz465 Pa @ 60 Hz 465 Pa 340 Pa @ 50 Hz

480 Pa @ 60 Hz 480 Pa

Noise level 67.9 dB(A) @ 50 Hz 71 dB(A) @ 60 Hz 72.9 dB(A) 67.9 dB(A) @ 50 Hz

71 dB(A) @ 60 Hz 71.9 dB(A)

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 324 x 324 x 94 mm

Cut out dimensions 175 x 175 mm (+0.5)

Material housing ABS-Plastic

Weight 2.1 kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60Hz 115V 60Hz 230V 50/60Hz 115V 60Hz

Rated current 0.31 A @ 50 Hz0.36 A @ 60 Hz 0.85 A 0.31 A @ 50 Hz

0.36 A @ 60 Hz 0.85 A

Power consumption 70 W @ 50 Hz81 W @ 60 Hz 97 W 70 W @ 50 Hz

81 W @ 60 Hz 97 W

FEATURES

Installation 4 x Ø 16 mm screws for thermoplastic material

Filtering class G3 according to EN 779

IP protection to IEC 60 529 IP 24 IP 54

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 30: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

30 www.seifertsystems.com

FL 6070A Top Mount Filter fan series

FL 6070A

Type FL 6070A 230V FL 6070A 115V

Part-no. 6070A4000 6070A3000

Part-no. EMC version 6070A4000E 6070A3000E

PERFORMANCE DATA

Max. airflow 420 m3/h @ 50 Hz 490 m3/h @ 60 Hz 490 m3/h

Static pressure 340 Pa @ 50 Hz 480 Pa @ 60 Hz 480 Pa

Noise level 67.9 dB(A) @ 50 Hz 71 dB(A) @ 60 Hz 71.9 dB(A)

Operating temp. range -10ºC - +55ºC

HOUSING DIMENSIONS

Dimensions (H x W x D) 324 x 324 x 94 mm

Cut out dimensions 175 x 175 mm (+0.5)

Material housing ABS-Plastic

Weight 2.2 kg

ELECTRICAL DATA

Voltage / frequency 230V 50/60Hz 115V 60Hz

Rated current 0.31 A @ 50 Hz 0.36 A @ 60 Hz 0.85 A

Power consumption 70 W @ 50 Hz 81 W @ 60 Hz 97 W

FEATURES

Installation 4 x Ø 16 mm screws for thermoplastic material

Filtering class G3 according to EN 779

IP protection to IEC 60 529 IP 55

Certification CE, cURus

Optional: Different housing colours available on request.

Q = Air flow [m3/h]P = Static pressure [Pa]

Page 31: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

31 www.seifertsystems.com

Accessor ies | F i l te r Fans FL ser ies

Spare f i l te r mats• Made o f thermo- l inked progress ive s t ruc tu re syn the t i c f ib re .

• F i l te r c lass G3, accord ing to EN 779. Other f i l te r c lasses l i ke G4 ava i lab le on reques t .

• UL 900 C lass 2 approved and se l f -ex t ingu ish ing in F1 c lass , accord ing to DIN 53 438.

• F i l te r med ia can be c leaned, up to 10 t imes by wash ing , b low ing d ry and l igh t l y bea t ing .

Outlet filter / filter fan Part numberFF - 4000 000 / FL - 40xx FM - 4000 000FF - 4000 100 / FL - 42xx FM - 4000 100FF - 4000 200 / FL - 44xx FM - 4000 200FF - 4000 300 / FL - 46xx FM - 4000 300FF - 4000 400 / FL - 48xx FM - 4000 400

EMC part-no. 4000 XXXE

Blank ing covers • I f the ex is t ing mount ing cu tou ts made to ins ta l l f i l te r fans need to be c losed,

the f i l te r mats can be rep laced us ing b lank ing covers thus e l im ina t ing the need

o f any we ld ing o r o ther mechan ica l mod i f i ca t ion .

Outlet filter / filter fan Part numberFF - 4000 000 / FL - 40xx FB - 4000 000FF - 4000 100 / FL - 42xx FB - 4000 100FF - 4000 200 / FL - 44xx FB - 4000 200FF - 4000 300 / FL - 46xx FB - 4000 300FF - 4000 400 / FL - 48xx FB - 4000 400

Sta in less s tee l hose-proo f weather / p ro tec t ion hoods• These covers a re par t i cu la r l y su i tab le fo r ou tdoor app l i ca t ions o r

i n the food indus t ry and are ava i lab le in a l l f i l te r fan s izes .

• Th is cover p ro tec ts aga ins t sp lashes o f l i qu ids and so l id fo re ign ob jec ts and is eas i l y washab le .

• NEMA / UL type 1 , 2 , 3R, 4 , 4x , 12 , 13 in p repara t ion .

Outlet filter / filter fan Part numberFF - 4000 000 / FL - 40xx FC - 4000 000FF - 4000 100 / FL - 42xx FC - 4000 100FF - 4000 200 / FL - 44xx FC - 4000 200FF - 4000 300 / FL - 46xx FC - 4000 300FF - 4000 400 / FL - 48xx FC - 4000 400

Page 32: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

32 www.seifertsystems.com

Thermostat (NC) / (NO) / Change-over Thermostat

ST 3980 / ST 3981 / ST 3990

Type ST 3980 ST 3981 ST 3990

Part-no. 3980000 3981000 3990000

Part-no. in oF 3980010 3981010 -

HOUSING DIMENSIONS

Material housing PA66 94V-0 PC / ABS

Dimensions (H x W x D) 68 x 29 x 45 mm 67 x 50 x 38 mm

Weight 0.54 kg 0.73 kg

ELECTRICAL DATA

Voltage / frequency 110 - 230 VAC / 50-60Hz 230 VAC / 50-60Hz

Rated current 10 A 10 A (cooling) 5 A (heating)

FEATURES

Operating temp. range -10ºC - +80ºC / 14ºF - 176ºF 0ºC - +60ºC32ºF - 140ºF

Connection Screw terminals

Mounting Snap on DIN rail 35 mm, 15 mm, 32 mm Clips for DIN rail 35 mm

IP protection to IEC 60 529 IP 20 IP 30

Certification CE, cURus CE

Note: Setting range: -10ºC - +80ºC Accuracy: +/- 3K

Page 33: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

33 www.seifertsystems.com

Twin Thermostat

ST 3982

Type ST 3982

Part-no. 3982000(NCNC)

3982001(NCNO)

3982002(NONO)

Part-no. in oF 3982010(NCNC)

3982011(NCNO)

3982012(NONO)

HOUSING DIMENSIONS

Material housing PA66 94V-0

Dimensions (H x W x D) 58 x 68 x 44.5 mm

Weight 0.1 kg

ELECTRICAL DATA

Voltage / frequency 110 - 250 VAC / 50-60Hz

Rated current 10 + 10 A

FEATURES

Operating temp. range -10ºC - +80ºC / 14ºF - 176ºF 0ºC - +60ºC32ºF - 140ºF

Connection Screw terminals

Mounting Snap on DIN rail 35 mm

IP protection to IEC 60 529 IP 20

Certification CE

Note: Setting range: -10ºC - +80ºC Accuracy: +/- 3K

Page 34: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

34 www.seifertsystems.com

Change-over Hygrostat

SF 3991

Type SF 3991

Part-no. 3991000

HOUSING DIMENSIONS

Material housing PC / ABS

Dimensions (H x W x D) 94 x 54 x 52 mm

Weight 0.155 kg

ELECTRICAL DATA

Voltage / frequency 120 - 230 VAC / 50-60Hz

Rated current 5 A

FEATURES

Operating temp. range 0ºC - +60ºC

Connection Screw terminals

Mounting Snap on DIN rail 35 mm

IP protection to IEC 60 529 IP 20

Certification CE

Note: Setting range 10ºC - +90RH Accuracy: +/- 5%RH

Page 35: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

35 www.seifertsystems.com

Sei fe r t | Thermal Management So lu t ions

A i r / wa ter hea t exchangers

Our compact a i r -water hea t exchangers can be used i f a co ld water supp ly i s ava i lab le . One typ ica l app l i ca t ion i s d iss ipa t ion o f h igh heat f rom cont ro l cab ine ts . Some mode ls a re ava i lab le as 19” p lug- in mode ls w i th min ima l dep th , as we l l as in te rna l , top and s ide mount ing . These indus t ry p roven heat exchangers d iss ipa te f rom 650 W up to 10 KW (L35W10@200 l /h ) . Wi th our modu la r sys tem se tup we can even reach per fo rmances o f up to 40 kW.

A i r / a i r hea t exchangers

O u r c o u n t e r f l o w a n d c r o s s f l o w h e a t e x c h a n g e r s a r e d e s i g n e d b o t h f o r o u t d o o r a n d i n d o o r a p p l i c a t i o n s . T h e S e i f e r t h i g h - e n d v a c u u m b r a z i n g t e c h n o l o g y i s b e s t - i n - c l a s s t h e r m a l d i s s i p a t i o n a n d m o s t c o m p a c t f o o t p r i n t i n t h e i n d u s t r y.

So l iTherm ComPact - the economica l a l l - round so lu t ion

The new So l iTherm ComPact l i ne has a new approach to the a i r cond i t ion ing o f con t ro l cab ine ts . The sur face t rea ted condenser and the h igh f in separa t ion p rov ide v i r tua l l y ma in tenance f ree a i r cond i t ioners fo r mos t o f the env i ronments . Based on our long exper ience in the deve lopment and produc t ion o f a i r cond i t ioners , we have op t im ized the ComPact ser ies to ach ieve a h igh e f f i c iency w i th ou ts tand ing COP va lues th roughout a l l mode ls . Re l iab i l i t y and user f r iend ly a re the bes t ways to descr ibe the e lec t ron ic con t ro l le r be ing used in the ComPact a i r cond i t ioners . The d isp lay ind ica tes tempera tu re and opera t ing s ta tus and can be eas i l y se t and ad jus ted by the user v ia a Touch Pad.

So l iTherm S l imL ine – f i l te r less a i r cond i t ioners

Max imum power to s ize ra t io – th is charac te r i zes the S l imL ine a i r cond i t ioners . Compat ib i l i t y w i th marke t s tandards ensures the cus tomer an easy in tegra t ion w i th h is enc losure o r cab ine t sys tems. S l i m L i n e a i r c o n d i t i o n e r s a r e d e s i g n e d t o o p e r a t e w i t h a b s o l u t e l y m i n i m u m m a i n -t e n a n c e . T h e y a r e e c o - f r i e n d l y a n d d o n o t n e e d d i r t c o l l e c t i n g f i l t e r m a t s . A l l S l i m L i n e m o d e l s c a n b e o p e r a t e d w i t h 3 p h a s e 4 0 0 V / 5 0 H z a n d 4 6 0 V / 6 0 H z . M o d e l s f r o m 3 2 0 W u p t o 1 . 5 K W a r e a v a i l a b l e . T h e u n i t s c a n b e e x t e r n a l l y o r i n t e r n a l l y m o u n t e d a n d a r e o n l y 11 0 m m d e e p a n d t h e r e f o r e c u r r e n t l y t h e s l i m m e s t a i r c o n d i t i o n e r s o n t h e m a r k e t . A s o n l y s m a l l a p e r t u r e s n e e d t o b e c u t f o r m o u n t i n g , t h e c a b i n e t d o o r s r e m a i n s t a b l e .

Pe l t ie r – coo l ing un i ts

The innova t ive Pe l t ie r thermoe lec t r i c techno logy p rov ides an e f fec t i ve coo l ing so lu t ion v i r tua l l y ma in tenance f ree . The So l iTherm Pe l t ie r a i r cond i t ioners incorpora te the techno logy w i th in a s leek and modern des ign wh ich i s compact and w i th on ly 64 mm depth hard ly needs any space.

Coo lMatch - var iab le coo l ing capac i ty fo r your cab ine t

The u l t ra -compact and l igh twe igh t a i r cond i t ioners a re spec ia l l y des igned fo r sma l l enc losures w i th l im i ted mount ing a rea , ex te rna l o r recessed mounted in to f la t hous ing opera to r o r par t o f a 19” rack w i th on ly 2 U un i t he igh t . They can be used bo th in ou tdoor and indoor app l i ca t ions .The Coo lMatch Ser ies se ts new per fo rmance- to -s ize s tandards wh ich makes i t par t i cu la r l y su i t -ab le fo r app l i ca t ions such as ba t te ry coo l ing . In case o f emergency the DC opera t ion a l lows the un i t to be ba t te ry opera ted . Ex t remely s tab le cab ine t tempera tu res w i th on ly + / -0 .2K are ob ta ined . A l l th is comes w i th s ign i f i can t energy sav ings !

Page 36: Control Cabinet · Seifert has nearly 50 years’ experience and expertise within the industrial thermal management. Extreme require-ments like in outdoor, military applications and

www.seifertsystems.com