changeable sheet a.ariga, nagoya univ. cs strategy r&d~2004-oct –bg rejection...
TRANSCRIPT
Changeable Sheet
A.Ariga , Nagoya univ
CS strategy• R&D ~2004-Oct
– BG rejection• Distortion distortion itself, precise measurement,
packing• Self-Refresh parameter study
– Aging test at high humidity• sensitivity , fog , etc.
• CS packing machine development ~2004-May• Production 2005-May ~ 1000CS/day
– Humid packing at Nagoya.– Initialization at Gran Sasso (self-refresh acceleration,
30degC 1month etc).
• Install– BAM,BMS
BG rejection by Microtrack-angle resolution improvement.
NBG (θ∝ allowance)4
Distortion Study
θallowance is decided by distortion. at present, maximum 50mrad.
Distortion study for CS.• How can we make good quality CS stably?
– must study develop on the view of distortion.
• Measures against...– Stripe distortion in FIX.– Reticulation in STOP.– Bubbles in Wash.– Glycerin non-uniformity.
• the limit of stage error.
Test Sample• film
– Non-Refreshed
– Refreshed
• exposure– 2GeV pion at KEK
– ~105 particle / cm2
low humidity packed
Stripe shape Distortion
4mm
Distortion by Stripe of emulsion surface.
Position X
x =
Mic
rotr
ack -
B
aset
rack
Amplitude = 10mrad
Direction of Stripe
it depends on the direction in Fix solution.
it is created by convective effect.
down in FIX solutions
disappeared when swing emulsion in FIX. (or circulation).
Reticulation on emulsion surface.
5mm
these pictures show surface of emulsion developed by usual recipe.
such non-uniformity is clearly bad.
and this make the wettability high, bad for drying.
these roughness was caused by STOP solution, especially with hardener Al2(SO4)3.
Disappeared by removing hardener in STOP.
Bubble distortion
9mm
Air bubbles in wash
water
this is veryveryvery heavy air bubbles. usually the size is <~ 0.1mm.
10mm
Use degassed water (not only wash)
Side view
less water circulation in this area.
bubble
emulsion
Glycerin non-uniformity.
Averaged in 300 micron
glycerin non-uniformity• To remove this non-uniformity
– alcohol+glycerin solution glycerin solution.– no use of drywell– remove glycerin solution completely by surface
tension before drying.
Glycerin solution
Distortion map after whole care...But
averaged in 200micron square.
mean x = -4.2mrad
x = 1.8mrad
mean y = -0.7mrad
y = 1.8mrad
Global distortion remained!
Distortion map after whole care.
stage X
stage Y
scanned 1.3mm x 1mm x 99point
on the stage
Rotate plate on the stage.
stag
e X
stag
e Y
on the stage
Global distortion looks correlated to how the emulsion sheet placed on the stage
origin of global distortion correlated to the stage.
z-axis stagger CCD
CCD camera move
we must develop blade spring type Z-drive (future plan)
Distortion on one plate.
x=1.5mrad y=1.6mrad
scanned 1mm x 1.3mm x 99point
believe only angle y (stage coordinate) and plot
Distortion map after correction
x = 1.8mrad
y = 1.8mrad
measurement err~1.2mrad
averaged in 200mm square.
(~=24tracks)
9mm
averaged in 200micron square.
But, the other side.• the distortion plotted before is only objective lens side.
Stage side distortion is still remained.
Develop a way to make emulsion itself hard.
or the other way.
Summary • Distortion is removed intrinsically.
– at the level of < 2mrad.
– Now observed distortion is dominated by the stage accuracy and measurement.
Future plan•About distortion
–Packing solution & mechanical stress.–a high precision stage must be developed to go further. –the way to make emulsion hard must be developed.
•About whole CS–sensitivity of high humidity pack–Aging–BG estimation