cell information

8

Click here to load reader

Upload: sangeen-ali-pti

Post on 28-May-2017

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cell Information

Show

Cell Information

Last updated: May 3, 2011

Cell Parameters

Reselection Parameters (lab application only)

Access Restriction Parameters (lab application only)

UE Timer and Constant Parameters (lab application only)

Message Reply Control (lab application only)

SIB19 Information (lab application only)

Reselection Parameters

This section is only applicable to the lab application.

These settings can only be changed when call status is Idle . If BCCH Update Page is set to Auto

and you change these settings while your UE is camped to the test set, the test set performs a Broadcast

Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the

default value) and you change these settings while your UE is camped to the test set, you must force your UE

to re-read the BCCH to observe the change (see BCCH Update Page for more details).

Sintersearch

You can specify whether the S intersearch

information element (see 3GPP TS 25.331 10.3.2.3 and 3GPP

TS 25.304 5.2.6.1.5) is sent in SIB3 by the test set, and if included, what value is sent. S intersearch

controls whether the UE must make measurements of inter-frequency cells while camped. If the quality

of the serving cell is above S intersearch

, then the UE will not measure other inter-frequency cells while

camped. If S intersearch

is not present, the UE must make inter-frequency measurements while camped.

Note that if the UE does not make measurements on other cells, it will not reselect away from the

current cell, even if there is another cell at a higher signal level. See 3GPP TS 25.304 5.2.6.1.1.

When Sintersearch is On , it can be set to any even number value between -32 dB and +20 dB,

but any negative value will be interpreted by the UE as 0 dB.

When Sintersearch is Off , the S intersearch

information element is not included in SIB3.

Note, the Sintersearch parameter does not affect measurements performed by the UE while on a

connection (see UE Reported Measurements ).

GPIB command: CALL[:CELL]:BCCHannel:SERSearch[:SVALue] .

Sintrasearch

Cell Information http://wireless.agilent.com/rfcomms/refdocs/wcdma/wcdma_gen_bse_cel...

1 of 8 2/26/2013 3:47 PM

Page 2: Cell Information

You can specify whether the S intrasearch

information element (see 3GPP TS 25.331 10.3.2.3 and 3GPP

TS 25.304 5.2.6.1.5) is sent in SIB3 by the test set, and if included, what value is sent. S intrasearch

controls whether the UE must make measurements of intra-frequency cells while camped. If the quality

of the serving cell is above S intrasearch

, then the UE will not measure other intra-frequency cells while

camped. If S intrasearch

is not present, the UE must make intra-frequency measurements while camped.

Note that if the UE does not make measurements on other cells, it will not reselect away from the

current cell, even if there is another cell at a higher signal level. See 3GPP TS 25.304 5.2.6.1.1.

When Sintrasearch is On , it can be set to any even number value between -32 dB and +20 dB,

but any negative value will be interpreted by the UE as 0 dB.

When Sintrasearch is Off , the S intrasearch

information element is not included in SIB3.

Note, the Sintrasearch parameter does not affect measurements performed by the UE while on a

connection (see UE Reported Measurements ).

GPIB commands: CALL[:CELL]:BCCHannel:SRASearch[:SVALue] .

Quality Measure

This parameter sets the 3GPP TS 25.331 s10.3.2.3, "Cell selection and reselection quality measure"

information element. This parameter specifies whether the UE should use CPICH Ec/N0 or CPICH

RSCP as the quality measure for determining which cell to choose when performing a cell selection or

mobile-initiated cell reselection.

Note, this setting does not affect what measurements are reported to the test set by the UE. When

Report Measurement Type is set to Intra-frequency or All , the UE will make both CPICH

Ec/N0 and CPICH RSCP measurements, regardless of the Quality Measure setting (the

Measurement Control message sent by the test set instructs it to do so).

GPIB command: CALL[:CELL]:RESelection:QUALity:MEASure .

Hysteresis 1 (Qhyst1)

This parameter sets the 3GPP TS 25.331 s10.3.2.3 "Qhyst1" information element. Qhyst1 specifies the

hysteresis value to be used by the UE if Quality Measure is CPICH RSCP.

GPIB command: CALL[:CELL]:RESelection:HYSTeresis[1] .

Hysteresis 2 (Qhyst2)

This parameter sets the 3GPP TS 25.331 s10.3.2.3 "Qhyst2" information element. Qhyst2 specifies the

hysteresis value to be used by the UE if Quality Measure is CPICH Ec/N0.

GPIB command: CALL[:CELL]:RESelection:HYSTeresis2 .

Minimum Required Quality Level (Qqualmin)

This parameter sets 3GPP TS 25.331 s10.3.2.3 "Qqualmin" for FDD in the "Cell selection and

Cell Information http://wireless.agilent.com/rfcomms/refdocs/wcdma/wcdma_gen_bse_cel...

2 of 8 2/26/2013 3:47 PM

Page 3: Cell Information

re-selection info for SIB11/12" information element (see 25.331 s10.3.2.4). According to 3GPP TS

25.304 s5.2.6.1.4, Qqualmin is the "minimum required quality level in the cell (dB)". If Quality

Measure is set to CPICH Ec/N0, the UE compares the CPICH Ec/N0 it measures for the cell with

Qqualmin to determine if it may select/reselect to the cell.

GPIB command: CALL[:CELL]:RESelection:QUALity:LMINimum .

Minimum Required Rx Level (Qrxlevmin)

This parameter sets 3GPP TS 25.331 s10.3.2.3 "Qrxlevmin" for FDD in the "Cell selection and

re-selection info for SIB11/12" information element (see 25.331 s10.3.2.4). According to 3GPP TS

25.304 s5.2.6.1.4, Qrxlevmin is the "minimum required RX level in the cell (dBm)". If Quality

Measure is set to CPICH RSCP, the UE compares the CPICH RSCP it measures for the cell with

Qrxlevmin to determine if it may select/reselect to the cell.

GPIB command: CALL[:CELL]:RESelection:RLMinimum .

Timer (Treselection)

This parameter sets the 3GPP TS 25.331 s10.3.2.3 "Treselection" information element. 3GPP TS

25.304 s5.2.6.1.4 states that the UE shall only reselect to a cell if it "is better ranked than the serving

cell during a time interval Treselection".

GPIB command: CALL[:CELL]:RESelection:TIMer .

Access Restriction Parameters

This section is only applicable to the lab application.

These settings can only be changed when call status is Idle . If BCCH Update Page is set to Auto

and you change these settings while your UE is camped to the test set, the test set performs a Broadcast

Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to Inhibit (the

default value) and you change these settings while your UE is camped to the test set, you must force your UE

to re-read the BCCH to observe the change (see BCCH Update Page for more details).

These parameters are sent in the Cell Access Restriction information element on SIB3. See 3GPP TS 25.331

s10.3.2.1.

Cell Barred State

According to 3GPP TS 25.304, a "Barred Cell" is "a cell a UE is not allowed to camp on." A UE is not

allowed to camp on a barred cell, not even for emergency calls. If a cell on which a UE is currently

camped becomes barred, a cell reselection is triggered.

This parameter controls whether the test set is a barred cell. It sets the 3GPP TS 25.331 s10.3.2.1 "Cell

Barred" information element.

GPIB command: CALL[:CELL]:AREStriction:BARRed:STATe .

Cell Barred Timer (Tbarred)

Cell Information http://wireless.agilent.com/rfcomms/refdocs/wcdma/wcdma_gen_bse_cel...

3 of 8 2/26/2013 3:47 PM

Page 4: Cell Information

This parameter sets the 3GPP TS 25.331 s10.3.2.1 "T barred

" information element. T barred

specifies the

time the UE must wait before considering a barred cell for reselection (see 3GPP TS 25.304 s5.3.1.1).

This setting is only applicable when Cell Barred State is set to On .

GPIB command: CALL[:CELL]:AREStriction:BARRed:TIMer .

Intra-frequency Cell Reselection Indicator

This parameter set the 3GPP TS 25.331 s10.3.2.1 "Intra-frequency cell re-selection indicator"

information element. According to 3GPP TS 25.304 s5.3.1.1, if a cell is barred, the UE must select

another cell as follows:

If the "Intra-frequency cell re-selection indicator" IE in Cell Access Restriction IE is set to value

"allowed", the UE may select another cell on the same frequency

If the "Intra-frequency cell re-selection indicator" IE is set to "not allowed" the UE shall not

re-select a cell on the same frequency as the barred cell. During an ongoing emergency call, the

Intra-frequency cell re-selection indicator IE" shall be ignored, i.e. even if it is set to "not

allowed" the UE may select another intra-frequency cell.

This setting is only applicable when Cell Barred State is set to On .

GPIB command: CALL[:CELL]:AREStriction:ITAFrequency:CRINdicator .

UE Timer and Constant Parameters

The following settings, with the exception of the T3312 Periodic RA Update Timer and T3312 Periodic RA

Update Units settings, can only be changed when call status is Idle . If BCCH Update Page is set to

Auto and you change these settings while your UE is camped to the test set, the test set performs a

Broadcast Channel (BCCH) Update Procedure (SIB Contents) . If BCCH Update Page is set to

Inhibit (the default value) and you change these settings while your UE is camped to the test set, you

must force your UE to re-read the BCCH to observe the change (see BCCH Update Page for more details).

T300 RRC Conn Req Retransmit Timer

This setting is only applicable to the lab application.

This setting determines how long the UE waits for the RRC Connection Setup after sending an RRC

Connection Setup Request.

T300 can be set to one of the following values: 100, 200, 400, 600, 800, 1000, 1200, 1400, 1600, 1800,

2000, 3000, 4000, 6000, or 8000 ms.

GPIB command: CALL[:CELL]:BCCHannel:T300

N300 RRC Conn Req Max Retransmits

This setting is only applicable to the lab application.

This setting specifies the maximum number of retransmissions of the RRC Connection Request

Cell Information http://wireless.agilent.com/rfcomms/refdocs/wcdma/wcdma_gen_bse_cel...

4 of 8 2/26/2013 3:47 PM

Page 5: Cell Information

message.

N300 can be set to any integer value from 0 to 7.

GPIB command: CALL[:CELL]:BCCHannel:N300

T312 Link Establishment Timer (Idle)

This setting is only applicable to the lab application.

This setting determines how long the UE waits for an N312 "in-sync" indication from layer 1 when

establishing a dedicated channel and the connection status is idle. According to 3GPP TS 25.331 table

10.3.3.43, zero (0) can be signaled in the SIB1 message but has no meaning.

T312 can be set to any integer value from 1 to 15.

GPIB command: CALL[:CELL]:BCCHannel:T312[:IDLE]

N312 Link Establishment In-Sync Count (Idle)

This setting is only applicable to the lab application.

This setting specifies the number of " in-syncs" required when establishing a dedicated channel when

the connection status is in Idle mode.

N312 can be set to one of the following values: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600, 800, or 1000.

GPIB command: CALL[:CELL]:BCCHannel:N312[:IDLE]

T308 RRC Conn Release Comp Retransmit Timer

This setting is only applicable to the lab application.

This setting specifies the amount of time between transmissions of the RRC Connection Release

Complete message.

T308 can be set to one of the following values: 40, 80, 160, or 320 ms.

GPIB command: CALL[:CELL]:BCCHannel:T308

N308 RRC Conn Release Comp Max Retransmits

This setting is only applicable to the lab application.

This setting specifies the maximum number of times the RRC Connection Release Complete message

is sent.

N308 can be set to any integer value from 1 to 8.

GPIB command: CALL[:CELL]:RRC:CRELease:N308

RRC Connection Release Complete Wait Count

Cell Information http://wireless.agilent.com/rfcomms/refdocs/wcdma/wcdma_gen_bse_cel...

5 of 8 2/26/2013 3:47 PM

Page 6: Cell Information

This setting is only applicable to the lab application.

This setting determines whether the test set keeps the uplink DPCH active until it has received all the

RRC Connection Release Complete messages or whether it releases the DPCH and returns to Idle

mode as soon as the first RRC Connection Release Complete message is received. Note: This

parameter only controls the test set's behavior; it is not signaled to the UE.

You can choose from the following settings:

N308 ( N308 ): The test set keeps the DPCH active until all the RRC Connection Release

Complete messages have been received.

1 ( RETRansmit1 ): The test set releases the DPCH upon the reception of the first RRC

Connection Release Complete Message.

GPIB command: CALL[:CELL]:RRC:CRELease:CWCount

T313 Out-Of-Sync Reception Timer

3GPP TS 25.331 8.5.6 states that after receiving N313 consecutive "out of sync" indications from layer

1 (see N313 Successive Out-Of-Sync Reception Max ), the UE shall start the T313 timer. Upon

receiving N315 successive "in sync" indications from layer 1 ( N315 Successive In-Sync Reception

Counter ), the UE shall stop and reset the T313 timer. If T313 expires, a "Radio Link failure" has

occurred, and the UE shall drop the call. See 3GPP TS 25.214 4.3.1.2 for more details regarding "in

sync" and "out of sync" indications.

T313 can be set to an integer value between 0 and 15 seconds.

GPIB command: CALL[:CELL]:BCCHannel:T313

N313 Successive Out-Of-Sync Reception Max

N313 can be set to one of the following integer values: 1, 2, 4, 10, 20, 50, 100, 200.

GPIB command: CALL[:CELL]:BCCHannel:N313

N315 Successive In-Sync Reception Counter

N315 can be set to one of the following integer values: 1, 2, 4, 10, 20, 50, 100, 200, 400, 600, 800,

1000.

GPIB command: CALL[:CELL]:BCCHannel:N315

T309 CCO From UTRAN to 2G Connect Timer

This setting is only applicable to the lab application.

This setting determines the amount of time the UE waits to establish a connection on the 2G side after

a Cell Change Order from UTRAN.

The T309 timer can be set to any integer from 0 to 8 seconds.

Cell Information http://wireless.agilent.com/rfcomms/refdocs/wcdma/wcdma_gen_bse_cel...

6 of 8 2/26/2013 3:47 PM

Page 7: Cell Information

GPIB command: CALL[:CELL]:BCCHannel:T309

T3212 Periodic Location Update Timer

This setting is only applicable to the lab application.

T3212 controls how often the UE performs the periodic location update procedure (see Performing a

Location Update (CS Domain Registration) ). It can be set between 0 and 255 decihours (1 decihour =

6 minutes). T3212 is signaled in SIB1 as part of the "CS domain specific system information"

information element. If T3212 is set to zero, 3GPP TS 24.008 indicates that the UE shall interpret this

as infinity (never perform a periodic location update).

GPIB command: CALL[:CELL]:BCCHannel:T3212

T3312 Periodic RA Update Timer

This setting is only applicable to the lab application.

This setting determines the value of the periodic Routing Area (RA) update timer. 3GPP TS 24.008

s4.7.2.2 states that "The value of timer T3312 is sent by the network to the MS in messages ATTACH

ACCEPT and ROUTING AREA UPDATE ACCEPT."

The increment value of this parameter is set by the T3312 Periodic RA Update Units parameters.

The T309 timer can be set to any integer from 0 to 31.

GPIB command: CALL[:CELL]:BCCHannel:T3312[:VALue]

T3312 Periodic RA Update Units

This setting is only applicable to the lab application.

This setting specifies the unit that the T3312 Periodic RA Update Timer is incremented.

The following settings are available:

2 Seconds ( SEC2 ): The T3312 Periodic RA Update Timer is incremented every 2 seconds.

Minutes ( MINutes ): The T3312 Periodic RA Update Timer is incremented every minute.

Decihours ( DHOurs ): The T3312 Periodic RA Update Timer is incremented every decihour (1

decihour = 6 minutes).

Deactivated ( DEACtivated ): The T3312 Periodic RA Update Timer is deactivated.

GPIB command: CALL[:CELL]:BCCHannel:T3312:UNITs

T305 Periodic Cell Update Timer

This setting is only applicable to the lab application.

T305 specifies the length of the periodical cell update timer. T305 starts while the UE is in

CELL_FACH state. When T305 expires, the UE initiates the cell update procedure.

Cell Information http://wireless.agilent.com/rfcomms/refdocs/wcdma/wcdma_gen_bse_cel...

7 of 8 2/26/2013 3:47 PM

Page 8: Cell Information

GPIB command: CALL[:CELL]:BCCHannel:T305

Related Topics

How Do I Change Cell Info?

Two-Cell Test System

Broadcast Channel (BCCH) Update Procedure (SIB Contents)

Cell Parameters

Cell Information http://wireless.agilent.com/rfcomms/refdocs/wcdma/wcdma_gen_bse_cel...

8 of 8 2/26/2013 3:47 PM