CITY OF HENDERSON 240 Water StreetP.O. Box 95050
Henderson, NV 89009
BUILDING & FIRE SAFETY702-267-3900
Fax 702-267-3901
Building PermitPermit Number: Permit Address:
66 ASTER BEACH AVE HENDERSON, NV 89011
BOTH2021131440Permit Type:
BLDG - Wall - Post HolePermit Name:PARCEL C-4 AT RAINBOW CANYON / IRON FENCE125' LF AT 5'LOT 78
Issue Date:03/24/2021Expiration Date:09/20/2021
Occupancy
Type of Construction
Permit Issued To:CPH HOLDINGS-HIRSCHI MASONRY, LLC
4120 LOSEE RDNLV, NV 89030(702) 399-2211
Contractor License Number74204
75957
NV20091548043Location Description:
IRON: under standard 2019053057125' LF AT 5'LOT 78
Building and Fire Safety ● (702) 267-3900 ● fax(702)267-3901 ● www.cityofhenderson.com
Building Permit
Building and Fire Safety
Page 2 of 3
PARCEL C-4 AT RAINBOW CANYON / IRON FENCE
125' LF AT 5'LOT 78
BOTH202113144066 ASTER BEACH AVE HENDERSON, NV 89011
City of Henderson
Applicant is responsible for complying with all applicable laws, regulations, and with all conditions specified by the City of Henderson.
The owner, owner's authorized agent, permittee and/or contractor is responsible to provide means for inspections, (i.e. ladders, temporary stairs and guards, etc.), to cause the work to remain visible and able to be accessed for inspection purposes.
The contractor and/or permittee scheduling inspections shall notify the owner and/or occupant of the inspection date and necessity to secure pets.
When scheduling inspections, we are currently not able to make appointments.
This permit is a multipage document. All pages must remain in a single package at the site and be accessible to city staff at all times. Permit Contents may include these sections: · List of Required Inspections · Inspection Holds (Requirements prior to scheduling certain inspections.) · Conditions of Approval · Special Inspections
· Inspection Scheduling Instructions. Inspections may be scheduled at http://dsconline.cityofhenderson.com.
Building and Fire Safety ● (702) 267-3900 ● fax(702)267-3901 ● www.cityofhenderson.com
Building Permit
Building and Fire Safety
Page 3 of 3
PARCEL C-4 AT RAINBOW CANYON / IRON FENCE
125' LF AT 5'LOT 78
BOTH202113144066 ASTER BEACH AVE HENDERSON, NV 89011
City of Henderson
List of Required Inspections This is a list of inspections required on this permit type. Certain inspections may not be required on your permit, if that specific construction is not included. There may be other inspections not on this list that may be required. If your project includes work that is not included on this list please contact City of Henderson Inspections Office at 702-267-3900. Certain inspections will not be available for scheduling until a prerequisite inspection, submittal, or other requirement is met. If a group of inspections has a hold, see the holds section of this permit for more information.
Inspection Description Date Inspector Inspection Description Date Inspector
Inspections - Walls and Fences1312 Post-Hole
Inspections - Pre-Slab1315 Setbacks
Certificate of Occupancy/Permit Final9999 Final Inspection
Certificate of Occupancy and Permit Final The final inspection will not be available for scheduling until all earlier inspections have been passed and all conditions of approval are addressed. When the final inspection is passed the permit is complete. An email will be sent indicating the permit is complete.
Building and Fire Safety ● (702) 267-3900 ● fax(702)267-3901 ● www.cityofhenderson.com
BOTH2021131440_SitePlan
City of HendersonBUILDING & FIRE SAFETY
APPROVED FOR CONSTRUCTIONSUBJECT TO FIELD INSPECTION & CODE COMPLIANCE
tjm503-11-2021
COMMUNITY DEVELOPMENTAPPROVALMar 11 2021
PLANNER'S SIGNATURE: EEp3
9080 W. Cheyenne Ave., Suite 120Las Vegas, NV 89129Ph: (702) 838-5311 Fx: (702) 838-5339
www.RimRockEngineering.com
PROJECT: Rainbow CanyonLOCATION: North of Lake Las Vegas ParkwayJURISDICTION: Henderson, NevadaPROJECT NO: 19-221-05CLIENT: Hirschi MasonryDATE:
SHEET INDEXBASIS FOR DESIGN 1CALCULATIONS 2
∆1 Plan check 10/09/20: sheet 2
10/9/2020
STRUCTURAL CALCULATIONS
THESE CALCULATIONS ARE THE SOLE PROPERTY OF RIM ROCK ENGINEERING ANDMAY NOT BE REPRODUCED IN WHOLE OR PART WITHOUT WRITTEN PERMISSION.CALCULATIONS ARE VALID ONLY FOR THE ABOVE NAMED PROJECT AND LOCATIONAND ARE NOT VALID UNLESS ENGINEERS ORIGINAL WET SIGNED SEAL IS AFFIXED
October 9, 2020
RIMROCKENGINEER ING
BUILDING CODE COMPLIANCE REVIEW
THIS SET OF PLANS AND SPECIFICATIONS HAVE BEEN REVIEWEDFOR COMPLIANCE WITH THE LOCALLY ADOPTED CODES RELATEDTO THIS PROJECTS SCOPE OF WORK
Oct 21, 2020
BY PAUL LUMINTERWEST CONSULTING GROUP
BOTH2019053057_StructCalcs_Rev3_v3
City of HendersonBUILDING & FIRE SAFETY
APPROVED FOR CONSTRUCTIONSUBJECT TO FIELD INSPECTION & CODE COMPLIANCE
ggg10-21-2020
BOTH2021131440_StructCalcBOTH2021131440_StructCalc
Gate Width B (ft): 8 Gate Max Weight (lb) 250Gate Elev h (ft): 5
Gate height s (ft): 5 Response Coeff (R): 1.25B/s: 1.63 Occupancy Factor (Ie): 1
s/h: 1.00 Ss: 0.4861 sec Period Acc'l (S1): 0.164
Wind Speed (mph): 93.0 Site Class: CExposure: C Design Spect'l Response (Sds): 0.42
Wind Pressure (psf): 18.1 Seismic Design Category: C% wind Pass through: 75% Seismic Response Coeff (Cs): 0.34Total Wind Load (lb): 106 V Seismic Load (lb) 84.2
- wind controls
Max Moment (lb-in): 3124.17 Tabe 6 of ER-265:Base Plate Width (in): 6 Tension at 4.5" embed: 4.5 1265
Base Plate Length (in): 4 Tension at 12" embed: 12 2715Anchor Bolt Clear Dist (in): 0.75 Req'd embedment (Interpolation): 6
# of Anchor per side: 1Max Tension/anchor (lb): 1562.09
Anchor Type: #4 reinf barFS (ksi): 32
fs (ksi): 7.81Min #4 bar lap length (in): 18
Min epoxy embed (in): 4.39Min specified embed (in): 6 Use Simpson SET-XP
Project: Project No.:
Location: Sheet No.:
Wind Load Design Seismic Load Design
Epoxy Calc
North of Lake Las Vegas Parkway 2
Rainbow Canyon 19-221-05
BOTH2021131440_StructCalc
’
“”
GENE
RAL S
TRUC
TURA
L NOT
ES
S0.1SHEET:
PROJ No.: 19-221-05
DATE: 08-28-20
DRAWN: CAD
CHECKED: CAD
DES
CR
IPTI
ON
REV
#D
ATE
TITL
E:
PRO
JEC
T:
SEAL:
10-09-20THIS
DO
CU
MEN
T IS
TH
E SO
LE P
RO
PER
TY O
F R
IM R
OC
K E
NG
INEE
RIN
G, L
LC. A
ND
MA
Y N
OT
BE
REP
RO
DU
CED
IN W
HO
LE O
R IN
PA
RT
WIT
HO
UT
EXPR
ESS
WR
ITTE
N P
ERM
ISSI
ON
. ALL
RIG
HTS
AR
E R
ESER
VED
RIMROCKENGINEERING
WW
W.R
IMR
OC
KEN
GIN
EER
ING
.CO
M
RAIN
BOW
CAN
YON
HEN
DER
SON
, NEV
ADA
NO
RTH
OF
LAKE
LAS
VEG
AS P
ARKW
AY
BUILDING CODE COMPLIANCE REVIEW
THIS SET OF PLANS AND SPECIFICATIONS HAVE BEEN REVIEWEDFOR COMPLIANCE WITH THE LOCALLY ADOPTED CODES RELATEDTO THIS PROJECTS SCOPE OF WORK
Oct 21, 2020
BY PAUL LUMINTERWEST CONSULTING GROUP
BOTH2019053057_StructPlan_Rev3_v3
SPECIALINSPECTIONS
REQUIRED
COH APPROVED - 10/22/2020
City of HendersonBUILDING & FIRE SAFETY
APPROVED FOR CONSTRUCTIONSUBJECT TO FIELD INSPECTION & CODE COMPLIANCE
ggg10-22-2020
BOTH2021131440_StructCalc