besamswingdooroperator sw200ius …€¦ · 1 revision followingpageshavebeenrevised: page revision...

82
Besam Swing Door Operator SW200i US Installation and Service Manual Original instructions 1007718-US-3.0 – Issue 2012-06-27 ASSA ABLOY, the global leader in door opening solutions

Upload: others

Post on 28-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Besam Swing Door OperatorSW200i US

Installation and Service ManualOriginal instructions

1007718-US-3.0 – Issue 2012-06-27

ASSA ABLOY, the global leader in door opening solutions

Page 2: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

© All rights in and to this material are the sole property of Besam US Inc.. Copying, scanning, alterations or modificationsare expressly forbidden without the prior written consent of the applicable company within BesamUS Inc.. Rights reservedfor changes without prior notice.

Backtrack information: folder: Library, version: a417, date: 2012-06-21, time: 13:01:22, state: Working

Page 3: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

CONTENTS

41 Revision ...............................................................................................................................

52 Important information ...........................................................................................................

73 Technical specification .........................................................................................................

94 How the SW200i works ........................................................................................................

145 Models .................................................................................................................................

166 Operator/Door handing ........................................................................................................

177 Part identification .................................................................................................................

188 Arm systems ........................................................................................................................

239 Options ................................................................................................................................

2710 Pre-installation .....................................................................................................................

3011 Mechanical installation .........................................................................................................

4712 Electrical connection ............................................................................................................

5913 Start-up ................................................................................................................................

6514 Changing group of parameters ............................................................................................

6915 Classification ........................................................................................................................

7016 Cover ...................................................................................................................................

7117 Troubleshooting ...................................................................................................................

7318 Maintenance plan ................................................................................................................

7419 ANSI / BHMA A156.10 .........................................................................................................

7920 ANSI / BHMA A156.19 (LOW ENERGY APPLICATION) ....................................................

3Issue 2012-06-271007718-US-3.0

CONTENTS

Page 4: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

1 Revision

Following pages have been revised:

Revision 2.0→3.0Page

OPS added to the OPD sensors11, 52, 64

1007718-US-3.0Issue 2012-06-274

1 Revision

Page 5: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

2 Important information

WARNING!

Failure to observe the information in this manual may result in personal injury ordamage to equipment.

To reduce the risk of injury to persons - use this operator with single or doublepedestrian swinging or folding doors only.

Save these instructions for future reference.

2.1 Intended use

The Besam SW200i is an automatic swing door operator developed to facilitate entrances tobuildings and within buildings through swing doors. The operator is only for indoor use. TheSW200i is a universal electro-mechanical operator that combines a Heavy Duty (HD) operatorfor large heavy doors with Low Energy (LE) applications of swing doors. The operator is factoryset to Low Energy (LE).

The Besam SW200i can be surface or concealed mounted on either side of the door header forpull or push action, and is suitable for single doors, double doors and double egress doors fittedwith swing clear hinges, offset or center pivots.

The Besam SW200i ensures all-around safety. The operator can be combined with a full rangeof sensor products providing swing door safety, but meets also the requirements for a low energyoperator without any sensors.

The operator is connected to the door leaf with a range of different arm systems.

The door is designed to offer continuous use, a high degree of safety and maximum lifetime.

For use see User manual 1007717.

2.2 Safety precautions

Do not climb on door parts.

Do not let children play with the door or the fixed controls.

Be sure to complete the site acceptance test before taking the door in to operation, see PRA-0007.

To avoid bodily injury, material damage and malfunction of the product, the instructions con-tained in this manual must be strictly observed during installation, adjustment, repairs and serviceetc. Training is needed to carry out these tasks safely. Only Besam-trained technicians shouldbe allowed to carry out these operations.

2.3 Electronic equipment reception interference

The equipment complies with the European EMC directive (US market FCC Part 15), providedinstalled according to Installation and Service manual.

5Issue 2012-06-271007718-US-3.0

2 Important information

Page 6: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

The equipment may generate and use radio frequency energy and if not installed and usedproperly, it may cause interference to radio, television reception or other radio frequency typesystems.

If other equipment does not fully comply with immunity requirements interference may occur.However, there is no guarantee that interference will not occur in a particular installation. Ifthis equipment does cause interference to radio or television reception, which can be determinedby turning the equipment off and on, the user is encouraged to try to correct the interference byone or more of the following measures:

• Re-orient the receiving antenna.

• Relocate the receiver with respect to the equipment.

• Move the receiver away from the equipment.

• Plug the receiver into a different outlet so that equipment and receiver are on different branchcircuits.

• Check that protective earth (PE) is connected.

If necessary, the user should consult the dealer or an experienced electronic technician for addi-tional suggestions.

Besam products are equipped with electronics andmay also be equipped with batteries containingmaterials which are hazardous to the environment. Remove this material from the operator beforeit is scrapped and make sure that it is disposed of properly as was done with the packaging.

This manual contains the necessary details and instructions for the installation, maintenanceand service of the Swing Door Operator Besam SW200i.

2.4 Glazing materials

The glazing material for swing doors shall comply with ANSI Z97.1

1007718-US-3.0Issue 2012-06-276

2 Important information

Page 7: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

3 Technical specification

Besam US Inc.Manufacturer:1900 Airport Road, US-Monroe, NC 28110Address:SW200iType:120 V AC +10/-15%, 50/60 HzPower supply:max. 300 WPower consumption:24 V DC, max. 700 mAAuxiliary voltage:2 x T 6,3 AH 250 VInternal control fuse:36-48” (914-1219 mm)Door width:Selectable: 12V DC, max. 1200 mA / 24 V DC, max. 600 mAElectro-mechanical locking de-

vice:100-700 lb. (45-315 kg)Door weight:PUSH: 80° - 110°, with reveal 0 - 12” (0 - 305 mm)Door opening angle:PULL: 80° - 110°, with reveal 0 - 5 1/8” (0 - 130 mm)PAS: only 80°-95°80°-95° in a concealed applicationvariable between 2 - 12 secondsOpening time (0° - 80°):variable between 4 - 12 secondsClosing time (90° - 10°):1,5-30 secondsHOLD open time:-4 °F to +113 °F (-20 °C to +45 °C)Ambient temperature:Max. 95%Relative humidity:19,8 lb. (9 kg)Drive unit weight:

This product is to be installed internally.Class of protection IP 20.Complies with: ANSI/BHMA A156.19, ANSI/BHMA A156.10, UL 325, UL 991, UL 244A, UL 1310,CAN/CSA-C22.2 N0 223-M91 and CAN/CSA-C22.2 N0 247-92

Third party approvals from established certification organizations valid forsafety in use and escape route safety. For details see Declaration of Confor-mity.

Approvals:

2 11/16’’

5 1/8’’

11

/2’’

11

/2’’

13

/8’’

4 5

/16

’’

5/8

’’

7Issue 2012-06-271007718-US-3.0

3 Technical specification

Page 8: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

3.1 Opening times

Opening time is adjustable from 2-12 seconds and dependent on the weight, width and installedarm system of the door. For max opening times on low energy doors, see Table I on page 79.

1007718-US-3.0Issue 2012-06-278

3 Technical specification

Page 9: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

4 How the SW200i works

The swing door operator SW200i uses a DC motor which is connected to the output shaft by acombination of a bevel gear and spur gears. The arm system that is connected to the output shaftopens the door in a wall mounted application.

There is also an adjustable spring mechanism connected to the output shaft. During opening ofthe door, the clock spring is tensioned by the rotation of the output shaft. During the closingcycle, the accumulated spring force is acting in the closing direction. The spring force can beadjusted so there is appropriate force to close the door when it is operated manually or in caseof a power failure.

4.1 Opening

When an opening signal is received by the control unit, the door is opened at the operator-ad-justed opening speed. Before the door is fully open at back check, it slows automatically to lowspeed. Themotor stops when the selected door opening angle has been reached. The open positionis held by the motor.

If the door is obstructed while opening, it will either stall or stop which can be selected with aDIP-switch (SOS). Stop on stall is always active in program selector Mode Off.

• Continue on stall - the door will continue to try to open during the hold open time.

• Stop on stall - the door will, even if hold open time has not expired, close after 2 seconds.

4.2 Closing

When the hold open time has elapsed, the operator will close the door automatically, usingspring force and motor. The door will slow to low speed at latch check before it reaches thefully closed position. The door is kept closed by spring power or combined with extendedclosing torque by the motor.

9Issue 2012-06-271007718-US-3.0

4 How the SW200i works

Page 10: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

4.3 Control switch

4.3.1 ON/OFF/HOLD open switch (option)

P/N: 1003582

FUNCTION

ONOFFHOLD

FU

NC

TIO

N

ON

OF

F H

OL

D

ProgramFunction

Impulses from activation units connected to XIMP are forwarded into inner impulse“CU-200” on page 52.

ON

Impulses from activation units connected to XIMP are not forwarded into innerimpulse. These units cannot open the door.

OFF

The door is held permanently open.HOLD

4.4 Functions on the basic control unit CU-200

Also see page 52 for more information.

4.4.1 Power failureDuring power failure the operator acts as a door closer with controlled closing speed. The microswitch located next to the spindle shaft can be adjusted to control when lock kick occurs.

4.4.2 Spring forceThe operator is delivered with spring pre-tension factory set to 360°. If necessary, the springtension can be electronically adjusted with a potentiometer to required closing force, but maxtotal 720°. The arm must also be relocated on the spindle.

4.4.3 Extended closing torque (CLTQ)If the potentiometer CLTQ is set to 0°, the door will close with normal spring power. If thepotentiometer is turned clockwise, the motor will increase the closing torque. Extended closingtorque will be reduced to zero:

• If the door mounted sensor presence detection is activated during the last 10° before closing.

• If the door mounted sensor presence impulse is activated in closed position or during closing(even if manually opened).

1007718-US-3.0Issue 2012-06-2710

4 How the SW200i works

Page 11: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

4.4.4 Power assist (POAS)If the potentiometer POAS is set to 0°, the door gives no power assist. If the potentiometer isturned clockwise, the motor will give/increase power assist when the door is opened manually.The range of the POAS is depending on the spring pre-tension.

4.4.5 Push and go (PAG)DIP-switch to select Push and Go, ON or OFF. Push and Go is available from any door position.Push and Go is not active in programme selector setting OFF.

4.4.6 Overhead presence detector (OPD/OPS), frame mountedWhen an OPD/OPS sensor is mounted on the frame or operator cover just above the swing sideof the door, it will–when activated–either keep the door open or closed. The sensor input is notsensitive during opening and closing. Lock-out signal is available as it is required by someOPD/OPS sensors for proper function.

• a closed door will not open, if the OPD/OPS detects activity in the field

• an open door will not close, if the OPD/OPS detects activity in the field

• during opening, the door will continue to open, even if the OPD/OPS detects activity in thefield

• during closing, the door will continue to close, even if the OPD/OPS detects activity in thefield

• the OPD/OPS is not active in program mode OFF or manually opened door

• during closing, if an activation occur the door will re-open.

4.4.7 Activation delay (AD)This function requires a constant inner impulse for the specified time before the door will open.Fixed 2 sec.

During closing the door will reopen immediately if impulsed.

4.4.8 MatMat safety means that:

• a closed door will not open, if someone steps on the mat

• an open door will not close, if someone steps on the mat

• during opening, the door will continue to open, even if someone steps on the mat

• during closing, the door will continue to close, even if someone steps on the mat

• opening impulses are prevented during closing, if someone steps on the mat

• the mat is not active in program mode OFF or manually opened door.

4.5 Functions on the extension unit EXU-SI

Also see page 55 for more information.

4.5.1 KILL function

In the event that the KILL circuit is activated, all Safety Functions of thedoor will be overridden causing the door to close even though an object orperson may be in the door's path of travel, and therefore may be subject to

11Issue 2012-06-271007718-US-3.0

4 How the SW200i works

Page 12: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

injury. This mode of operation is most generally used to isolate an area inthe event of a fire.

• During KILL, the control will ignore all signals and close door(s) at normal speed.

• If impulse controlled KILL: The operator will resume normal operation after a KILL RESET.When manual RESET, jumper must be removed and reset button connected to terminal No.8 and Ground.

• Or if state controlled KILL: When KILL signal is no longer active, operator will resumenormal operation.

• The behavior of the lock during KILL depends on the group of parameters. See page 65.

• The KILL input may be connected to either a normally open contact with GND as referenceor a normally closed contact with QTST as reference, depending of group of parameters,see page 65.

4.5.2 Function of locks• The lock output only works when the function switch is in OFF or EXIT. If no function

switch is used, OFF or EXIT must be connected to GND (0 VDC).

• The control has an available output of DC for external locks

• DIP-switches to select 12 or 24 V DC, locked with or without power

• DIP-switch for lock release and potentiometer for opening delay

• DIP-switch for lock kick to overcome binding in the locking device during closing

• Input to unlock signal from lock. Potentiometer for opening delay is to be set to max. Assoon as unlock signal is received the door will start to open. The lock output signal shall beactive low.

• If the door cannot fully close, the operator will perform a lock retry (once if manually open,twice if automatically open).

4.5.3 Panic barPanic bar can be disabled by the relay function on the extension board EXU-SA and an externalpower supply. Panic bar will then only be active during KILL. See Changing group of parameterson page 65.

4.5.4 Program selector (wall mounted)• Input for OPEN, EXIT and OFF (if no program selector, AUTO is default).

Note: In OFF-position the operator will comply with the Low Energy Regulation.

4.5.5 Impulses• Input for OUTER impulse, KEY impulse and OPEN/CLOSE impulse.

4.5.6 OPEN/CLOSE impulseThe impulse will open the door and the door will stay open until a new impulse is given. If noimpulse is given the door will close after 15 minutes. This can be made infinite by changinggroup of parameters, see page 65.

OPEN/CLOSE impulse works only in program selection AUTO. Can be programmed for OFFand EXIT as well. See page 65.

1007718-US-3.0Issue 2012-06-2712

4 How the SW200i works

Page 13: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

4.6 Functions on the extension unit EXU-SA

Also see page 56 for more information.

4.6.1 Presence impulse approach, door mounted / Door mounted presence sensor,non swing side (DMPS.NS)The presence impulse is active during fully open and closing. The sensor is mounted to the ap-proach side of the door. Once the door is closed, the sensor is ignored and will not be activeuntil the next impulse is received.

Note: When installed as a pair of doors, the presence impulse signal will re-open both doors.The sensor is not active in program mode OFF or manually opened door (Power Failure Modeor during KILL function).

4.6.2 Presence detection swingpath, door mounted / Door mounted presence sensor,swing side (DMPS.SS)When a sensor that is mounted on the swing side of a door detects an object, it will send acommand to the control unit to stall the door. If the control unit has received a short signal fromthe sensor and there is still hold open time left on the control unit, the door will continue on itsway open if the object has cleared.

The inhibit/blanking potentiometer can be adjusted so that the sensor will avoid detecting a wallor object near the full open position. Presence detection has a higher priority than presence im-pulse.

Note:When installed as a pair of doors the presence detection signal will stop both doors, exceptfor double egress doors. The behavior for double egress doors can be changed . The sensor isnot active in programmode OFFor manually opened door. In this OFF-mode the operator fulfillsthe Low Energy Standards.

4.6.3 Monitored safety sensorsBoth presence impulse and presence detection can be monitored. If a sensor becomes defective,the operator will not accept any impulses and will then work as a manual door closer.

4.6.4 Relay output• Error indication

A potential free contact COM/NO/NC for external error indication, see “Error indication”onpage 72.

• KILL outputNO or NC signal

• Door indicationUsed to indicate an open or closed position of the door. The indication position is set byadjusting the inhibit/blanking potentiometer.

• Panic barParameter group 14

13Issue 2012-06-271007718-US-3.0

4 How the SW200i works

Page 14: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

5 Models

The Besam SW200i operator can be surface mounted or concealed installed. These two versionscan be used in the following installations:

• Single doors

• Double doors (two operators)

• Double egress doors (two operators)

The operators are non-handed and not dependent on the hinges. The operators suit both pushingand pulling arm systems.

5.1 Single operator, surface mounted

The product is delivered complete with back plate, control unit, end plates and cover. Lengthincluding end plates, L = 39.5” (1003 mm).

Pushing arm system shown. Other lengths are optional.

L

5.2 Double operator, surface mounted

Note: Consult Product Order form for availability

The product is delivered complete with back plate, control unit, end plates and cover. Coverlength L is optional.

Two operators can be mounted under the same cover to open one door each. Pushing and pullingarm system shown (double egress).

It is also possible to use two pushing or two pulling arm systems.

L

1007718-US-3.0Issue 2012-06-2714

5 Models

Page 15: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

5.3 Concealed mounted

The concealed operator is used to control a center-pivot door, with the operator integrated andconcealed in the header above the door. The door can be opened in a direction opposite to normalin an emergency (panic breakout). Manual reset by pushing the door back into normal operationsector is necessary.

A concealed operator can also be installed in the ceiling space above the door (bottom load).Such applications may require field engineering of components and hardware.

Operator for right handed door

Operator for left and right handed door

15Issue 2012-06-271007718-US-3.0

5 Models

Page 16: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

6 Operator/Door handing

6.1 Operator handing

80/11/6 01 snoituloS ecnartnE maseB

80/11/6 01 snoituloS ecnartnE maseB

Pull

Concealed

Surface Applied

Push

Left hand Right hand

Right hand Left hand

Right hand Left hand

Left hand Right hand

6.2 Door handing

Door handing is determined by standing with your back to the hinges. The side that the doornormally opens (right or left) is the handing of the door. The illustration below shows a right-handed door.

1007718-US-3.0Issue 2012-06-2716

6 Operator/Door handing

Page 17: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

7 Part identification

7.1 Surface mounted - Side loaded

DescriptionArt. No.Item No.

Back plate1Transmission unit3310072912Control unit CU-2003310077523Control unit CU-200 with EXU-boards331008346EXU-SA331003557EXU-SI331003554Stop arm kit3300002764End plate kit10091325Cover6ON/OFF/HOLD open switch3310035827Knockouts for cable inlet–8Connection box331007504 BK9Adaptor kit330000270 SI/BK10Micro switch kit incl. cam33000027511Fixing kit33100732712Sync cable – optional331003583PUSH Arm service kit330000271 SI/BKPULL/PAS Arm service kit330000272 SI/BKRocker Switch ON/OFF330000330Encoder cable331009105

17Issue 2012-06-271007718-US-3.0

7 Part identification

Page 18: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

8 Arm systems

8.1 Pushing installation with PUSH-arm

This arm system is delivered with drive arm, telescopic part and door fitting. It is used if theoperator is installed on the wall on the opposite side of the door swing, and approved for firedoor application.

P/N:1007241BK, 1007241SI

A

Frame depthHigh PerformanceStandardExtension

8 1/4”(210 mm)

14°

2 3/8”(60 mm)

3 3/4”(95 mm)

40°

7 5/8”(194 mm)

Telescopic partL= 13 1/2" (345 mm)

P/N: 173005

Telescopic partL= 9 1/2" (230 mm)

P/N: 173004

Joint assembleP/N: 173191

A = revealA = reveal

0 to 3 7/8" (0-99 mm)0 to 3 3/4" (0-95 mm)None (Standard arm)

3 7/8 to 9 1/16" (99-230 mm)3 3/4 to 8 1/4" (95-210 mm)Telescopic part L=13 1/2" (345 mm)

9 1/6 to 14 1/4" (230-362 mm)8 1/4 to 13 1/32 " (210-335 mm)Extension L=9 1/2" (230 mm) + jointpart

1007718-US-3.0Issue 2012-06-2718

8 Arm systems

Page 19: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

8.2 Pulling installation with PULL-arm

This arm system is delivered with drive arm, guide shoe and door fitting.

P/N: 1007251BK, 1007251SI

8 1/4” (210 mm)3 3/4” (95 mm)

19Issue 2012-06-271007718-US-3.0

8 Arm systems

Page 20: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

8.3 Pulling installation with PAS-arm

This arm system consists of main arm, slide track, roller guide and shaft adaptor. It can be fittedon combinations of doors and jambs (walls), where the total reveal from the wall line to thedoor leaf does not exceed 5 1/8".

P/N: 1007476BK (left), 1007476SI (left)

P/N: 1007247BK (right), 1007247SI (right)

1007718-US-3.0Issue 2012-06-2720

8 Arm systems

Page 21: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

8.4 Pushing installation with PULL-arm (Sliding PUSH)

This arm system consists of main arm, slide track, guide shoe and shaft adaptor. It can be fittedon combinations of doors and jambs (walls), where the wall thickness does not exceed approx.4 1/2". Dimensions given here correspond to an opening angle of 90-100°.

P/N: 1007251BK, 1007251SI

8 1/4” (210 mm)

Max. 4 1/2” (114 mm)

3 3/4” (95 mm)

Note: Limited performance not for windy condition or high stack pressure. Maximum doorweight 265 lbs and width 48".

8.5 Double door installations

There are four different types of double door installations:

• Astragal –Has an overlapping master door, can be opened synchronously if it is not jammingand must be closed asynchronously to avoid that the doors will jam or close in the wrongorder.

• Jamming – This door type needs to be opened and closed asynchronously to avoid that thedoors will jam with each other.

• Not jamming, not rebated – This door type has doors that always can move independentlyof each other and can be opened and closed synchronously.

• Double egress – This door type has doors that opens in different directions which can beopened and closed independently. This door type may have a different way of handlingsafety sensors due to the difference in opening direction of the doors.

Also see page 57.

21Issue 2012-06-271007718-US-3.0

8 Arm systems

Page 22: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

8.5.1 Nurse and bed functionalityConnect a 1/0-switch to the slave control unit. This will make it possible to open only the masterdoor, and both doors if necessary.

If Push and Go is ON the bed functionality can also be achieved by manually pushing the slavedoor which will start the door to open manually.

8.6 Drive shaft extension kits

3/4"

(20 mm)

P/N: 1008396 BK/SI P/N: 1008398 BK/SI

2"

(50 mm)

P/N: 1008400 BK/SI

2-3/4"

(70 mm)

1007718-US-3.0Issue 2012-06-2722

8 Arm systems

Page 23: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

9 Options

9.1 Push plates

For DISABLED or ADA use, mount push plate 31” above floor level.

9.1.1 Push plates

P/N: 75-02-101

PRESSTO OPEN

P/N: 75-02-102

P/N: 75-02-107

PRESSTO OPEN

P/N: 75-02-108

P/N: 75-02-280

9.1.2 Remote transmitter push plates

PUSHTO OPEN

P/N: 75-02-273

PUSHTO OPEN

P/N: 75-02-272

PUSH

TO

OPEN

P/N: 75-02-269

PUSH

TO

OPEN

P/N: 75-02-270

9.1.3 Installation box for narrow plates

P/N: 75-21-002

9.1.4 Remote receiver

P/N: USRD433

23Issue 2012-06-271007718-US-3.0

9 Options

Page 24: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

9.2 Sync cable for double doors (synchronizing of 2 operators)

Note: The connection/marking of the sync ca-ble determines which of the operators is theMASTER and SLAVE

MASTER SLAVE

RedBlack

P/N: 331003583

9.3 Accessories

PS-4CP/N: 655845

3-position switchP/N: 75-15-310 ClearP/N: 75-15-310 Black

Surface mounting boxP/N: 655806

ON/OFF/HOLD open switchP/N: 1003582

P/N: 1003582

FUNCTION

ONOFFHOLD

For use with PS-4C (P/N: 655845)LED CableP/N: 1008615

1007718-US-3.0Issue 2012-06-2724

9 Options

Page 25: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

9.4 Labels

Label kit P/N: 331007317

DO NOT

ENTERAUTOMATIC

DOOR75-20-101

AUTOMATIC

DOOR

75-20-100

Dual Side “AUTOMATIC DOOR / DO NOT EN-TER” – In

Dual Side “AUTOMATIC DOOR / DO NOT EN-TER” – Out

21-24-005

AUTOMATIC

DOOR

CAUTION

75-20-102

Dual side "Operator designed for disabled people"Dual Side “AUTOMATIC DOOR / CAUTION”

PULL TO

ACTIVATEPUSH TO

ACTIVATE

Pull side “PULL TO ACTIVATE”Push side “PUSH TO ACTIVATE”

ACTIVATESWITCH TOOPERATE

"Danger"Dual Side “Activate Switch to Operate”

These minimal safety

checks in addition to

those in the Owner’s

Manual, should be made

each day and after any

loss of electrical power.

PLACE COMPLETED

ANNUAL COMPLIANCE

INSPECTION LABEL

HERE

#50-24-020

DO NOT USE DOOR if it

falls any of these safety

checks or if it

malfunctions in any way.

Call a qualified automatic

door service company to

have door repaired or

serviced.

See Owner’s Manual or

instructions for details on

each of these and other

safety items. If you need a

copy of the manual,

contact the manufacturer.

1. Walk toward the door at a

normal pace. Door should

open when you are about 4

feet from the door.

2. Stand motionless on

threshold for at least 4

seconds. Door should not

contact you.

3. Walk into the swing area and

stop for 10 seconds. Door

should not contact you.

4. Move clear of the area. Door

should remain open for at

least 1.5 seconds and

should close slowly and

smoothly. If two-way traffic,

move toward swing side of

door. Door should open well

before you reach the swing

path.

5. Inspect the floor area. It

should be clean with no

loose parts that might cause

user to trip or fall. Keep

traffic path clear.

6. Inspect door’s overall

condition. The appropriate

signage should be present.

Guide rails and finger guards

should be in good condition.

7. Have door inspected by an

AAADM certified inspector at

least annually.

SAFETY INFORMATION

Automatic Swinging

Doors

SAFETY INFORMATION

Low Energy Swinging

Doors

These minimal safety

checks in addition to

those in the Owner’s

Manual, should be made

each day and after any

loss of electrical power.

PLACE COMPLETED

ANNUAL COMPLIANCE

INSPECTION LABEL

HERE

US24-0489-01

DO NOT USE DOOR if it

falls any of these safety

checks or if it malfun-

ctions in any way. Call a

gualified automatic door

service company to have

door repaired or serviced.

See Owner’s Manual or

instructions for details on

each of these and other

safety items. If you need a

copy of the manual,

contact the manufacturer.

1. Activate the door. Door

should be open at a slow

smooth pace (4 or more

seconds), and stop without

impact.

2. Door must remain fully open

for a minimum of 5 seconds

before beginning to close.

3. Door should close at a slow

smooth pace (4 or more

seconds), and stop without

impact.

4. Inspect the floor area. It

should be clean with no

loose parts that might cause

user to trip or fall. Keep

traffic path clear.

5. Inspect door’s overall

condition. The appropriate

signage should be in good

condition.

6. Have door inspected by an

AAADM certified inspector at

least annually.

#US24-0542-01

ANNUAL COMPLIANCE

INSPECTION

Inspected for and complies with

ANSI A156. _______________

DATE: _______________

by AAADM Certified

Inspector

Number:_______________

"Safety information""Certified Inspector"

25Issue 2012-06-271007718-US-3.0

9 Options

Page 26: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Product label P/N: 1008999

1007718-US-3.0Issue 2012-06-2726

9 Options

Page 27: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

10 Pre-installation

10.1 Types of installation

Surface InstallationSurface Applied means that the operator and header are mounted on the surface of the wall, andan external arm system is used to operate the door.

A surface applied header is typically 3” longer than the concealed in order to attach easily tothe jambs.

Standard installation is made with the distance 3 3/4" (95 mm) from hinge CL to outgoing shaft.

High performance installation, used in windy conditions and heavy doors is made with the dis-tance 8 1/4" (210 mm) from hinge CL to outgoing shaft.

Retrofit installations may be done even with the distance of 2 3/4" (70 mm) from hinge CL tooutgoing shaft.

10.2 General tips/Safety concerns

• For enhanced security and vandalism protection, always mount the operator access in theinterior of a building whenever possible.

• Make sure that the power is off before installing.

• Make sure that the door leaf and the wall are properly reinforced at the installation points.

• Inspect the door hinges before installation to ensure that they are in good repair.

• Unpack the operator and make sure that all parts are delivered in accordance with the packingnote.

27Issue 2012-06-271007718-US-3.0

10 Pre-installation

Page 28: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

10.3 Installation examples

Non combustiblematerial in fireapplication

Non combustiblematerial in fireapplication

Steel reinforcement or rivnutAWood reinforcementBExpansion-shell bolt (for brick wall min.M6x85, UPAT PSEA B10/25)

C

Aluminium profile system1Plasterboard wall2Reinforced concrete wall and brick wall3Plasterboard wall4

1007718-US-3.0Issue 2012-06-2728

10 Pre-installation

Page 29: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

10.4 Fastening requirements

Minimum requirements of wall profile*Base material

3/16" (5 mm)**Steel1/4" (6 mm)**Aluminiummin. 2" (50 mm) from the undersideReinforced concrete2" (50 mm)WoodExpansion-shell bolt, min.M6x85, UPAT PSEAB10/25, min.2" (50 mm) from the underside

Brick wall

* Besamminimum recommended requirements. Building Codesmay give different specifications.Refer to AHJ (Authority Having Jurisdiction).

** Thinner wall profiles must be reinforced with rivnuts.

10.5 Tools required

• Metric Allen keys 3; 4; 5 and 6 mm

• Tool for screw between cover and backplate (?)

• Flatblade screwdriver (potentiometer and terminal size)

• Screwdriver (Philips size 2)

• Nut driver, 5 mm

• Tape rule

• Power drill and set of drill bits

• Center punch

• Wire stripper

• Silicone sealant

• Installation and Service Manual (this manual)

10.6 Installation on double doors

If the operators are to be mounted at the same height with pushing and pulling arm systems, theheight is determined by the pulling arm system, PULL. The pushing arm system PUSH mustalways have a shaft extension, minimum 2" (50 mm), maximum 2 3/4” (70 mm) to match themounting heights visually.

Example: if PULL has a 3/4” (20 mm) extension, the PUSH must have a 2 3/4” (70 mm) exten-sion. If PULL has 0” mm extension, the PUSH must have a 2” (50 mm) extension.

For installation, follow the instructions for the applicable arm system.

29Issue 2012-06-271007718-US-3.0

10 Pre-installation

Page 30: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

11 Mechanical installation

11.1 Surface mounted installation

The operator is mounted on either side of the door header with two available spindle locations,Standard 3 3/4" (95 mm) and High performance 8 1/4"(210 mm) between hinges and outgoingshaft, depending on type of doors.

The Standard installation is best suited according to ANSI / BHMAA156.19 and ADA 28 CFRPart 3. The High performance installation is used in windy environments, when heavy doorsare used and when there are big differences in pressure.

The door is controlled with a push or pull arm system.

Note: Consider all power wire entry locations and signaling wires before preparing back plate.

High performance 8 1/4" (210 mm)Standard 3 3/4" (95 mm)

B

A

C

B

C

A

10" (255 mm)A

28 3/8" (720 mm)B

1 3/8" (36 mm)C

5 1/2" (140 mm)A

28 9/16" (725 mm)B

28 5/8" (726 mm)C

8 1/4"1

11/16"

3 3/4"1

11/16"

1007718-US-3.0Issue 2012-06-2730

11 Mechanical installation

Page 31: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

11.1.1 PUSH arm system

Reveal

0" - 9/16" (0 - 14 mm) 1 7/8" (48 mm)

0" - 1 3/8" (15 - 35 mm) 2 11/16" (68 mm)

0" - 2 9/16" (36 - 65 mm) 3 7/8" (98 mm)

0" - 3 3/8" (66 - 86 mm)2 3/4" (70 mm)

X Y

4 5/8" (118 mm)

3/4" (20 mm)

2" (50 mm)

_

1 3

/ 8"

(35

mm

)

CL 2

PUSH

X

Y

≤ 12"

Shaft extension

Reveal

Shaft extension

See page 32 for 3 3/4" (95 mm) installation.See page 35 for 8 1/4" (210 mm) installation.

31Issue 2012-06-271007718-US-3.0

11 Mechanical installation

Page 32: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Operator with PUSH arm system 3 3/4" (95 mm)

1007718-US-3.0Issue 2012-06-2732

11 Mechanical installation

Page 33: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Cont."Operator with PUSH arm system" 3 3/4" (95mm)

33Issue 2012-06-271007718-US-3.0

11 Mechanical installation

Page 34: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Cont."Operator with PUSH arm system" 3 3/4" (95 mm)

Do not tighten.

Loosen all four screws.

Align markings on drive arm andtelescopic arm to achieve 40 degreesbetween the arms.

Hold the door a bit open whentighten the screw.

See table Frame Depth on page 18 for available extensions.

Continue on page 47.

1007718-US-3.0Issue 2012-06-2734

11 Mechanical installation

Page 35: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Operator with PUSH arm system 8 1/4" (210 mm)

35Issue 2012-06-271007718-US-3.0

11 Mechanical installation

Page 36: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Cont."Operator with PUSH arm system" 8 1/4" (210mm)

1007718-US-3.0Issue 2012-06-2736

11 Mechanical installation

Page 37: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Cont."Operator with PUSH arm system" 8 1/4" (210 mm)

Do not tighten.

Loosen all four screws.

Note: Important measurementfor correct opening andclosing force.

Hold the door a bit open when tightenthe screw.

Continue on page 47.

37Issue 2012-06-271007718-US-3.0

11 Mechanical installation

Page 38: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

11.1.2 PULL/PAS arm system

1007718-US-3.0Issue 2012-06-2738

11 Mechanical installation

Page 39: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Operator with PULL/PAS arm system 3 3/4" (95 mm)

X = Center of the guide shoe movement. See page 45 how to measure the distance.

39Issue 2012-06-271007718-US-3.0

11 Mechanical installation

Page 40: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Cont. Operator with PULL/PAS arm system 3 3/4" (95 mm)

X = Center of the guide shoe movement. See page 45 how to measure the distance.

Continue on page 43 or 44.

1007718-US-3.0Issue 2012-06-2740

11 Mechanical installation

Page 41: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Operator with PULL arm system 8 1/4" (210 mm)

X = Center of the guide shoe movement. See page 45 how to measure the distance.

41Issue 2012-06-271007718-US-3.0

11 Mechanical installation

Page 42: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Cont. Operator with PULL arm system 8 1/4" (210 mm)

X = Center of the guide shoe movement. See page 45 how to measure the distance.

1007718-US-3.0Issue 2012-06-2742

11 Mechanical installation

Page 43: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Cont. "Operator with PULL arm system"

CL 1

III

5

3x2

3

Click

Click

4

CL 2

Left hand

Right hand

IV

I I I I I I I I I I I I I I I I I I 37 lbf·ft (50 Nm)

3

1

3

Do not tighten.

Do not tighten.

Hold the door a bit open when tighten the screw.

43Issue 2012-06-271007718-US-3.0

11 Mechanical installation

Page 44: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Cont. "Operator with PAS arm system"

CL 1

5

3x2

3

Click

Click

4

CL 2

III

Left hand

Right hand

IV

I I I I I I I I I I I I I I I I I I 37 lbf·ft (50 Nm)

1

3

3

Do not tighten.

Do not tighten.

Hold the door a bit open when tighten the screw. Loosen the doorstop and let the door close fully.

1007718-US-3.0Issue 2012-06-2744

11 Mechanical installation

Page 45: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

a Locate the door in closed position.

b Fix the main arm with guide shoe (1) loose onto the operator shaft so that the guide shoe isjust in contact with the door.

c During the opening and closing movement of the door, the guide shoe (1) will move a certaindistance on the door. Mark the end positions for this distance.

Note: The end positions do not always occur when the door is fully closed and fully open.

d Position the slide track (3) symmetrically over the marks on the door, with the centre of thefixing holes, W+ 2 1/8" (see table on page 38), from the lower edge of the operator. Markon the door for the fixing holes. Drill and thread or use rivnuts.

e Attach the slide track (3) to the door with the guide shoe (1) fitted into the track. Use appro-priate screws.

2

1 3

Guide shoe1Main arm2Slide track3

45Issue 2012-06-271007718-US-3.0

11 Mechanical installation

Page 46: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

11.1.3 Operator with sliding PUSH arm system

0

25/32" (20 mm)

2" (50 mm)

2 3/4" (70 mm)

Y

CL 2

Shaft extension

1 3

/ 8"

(35

mm

)

PUSH

Y

max. 4 1/2"

2 3/16"

(56 mm)

7/8" (22 mm)

1 21/32" (42 mm)

2 13/16" (72 mm)

3 5/8" (92 mm)

For installation see PULL arm system on page 38.

1007718-US-3.0Issue 2012-06-2746

11 Mechanical installation

Page 47: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

12 Electrical connection

Note: The installation shall be made according to local codes.

When working in, with or around electrical circuits, all power must be disconnected.

12.1 Connection box, single door

Fit the connection box in the back plate as shown below.

Note: To ensure for sufficient grounding, the square nuts must be turned with the teeth upwardsagainst the box so that they cut through the anodizing in the back plate.

a Switch off the electrical power.

b Unscrew the lid (1).

1

47Issue 2012-06-271007718-US-3.0

12 Electrical connection

Page 48: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

c Strip approximately 5 inches off from the outer insulation of the power installation cable(2).

d Insert the free end of the power installation cable into the connection box (3) through themetal strain relief (4).

e For the following connections: Use twist-on wire connectors (“wire nuts”) (5), that are ap-proved for the application. The wires should be stripped according to the instructions for theused wire connector. Be aware, local code shall be followed.

• Connect the (white) neutral wire of the power installation cable with the AWG18 (white)neutral wire that extends from the CPD metal housing (6).

• Connect the (black) phase wire of the power installation cable with the free AWG18(black) wire of the cable of the rocker switch assembly (7).

• Connect the solid green earth wire (8), that is attached to the bottom of the connectionbox, with the green earth wire of the power installation cable (2), and the green earth wireof the interconnection cable (9).

f Tuck the slack of the wires into the largest compartment, between the CPD metal housing(6) and the wall of the connection box. Be careful not to place connectors, or excessive loopsof wire, on top of the CPD metal housing as they might interfere with the fastening of thecover.

g Fasten the lid (1) of the connection box.

24

3 5

5

6

8

7

9

1007718-US-3.0Issue 2012-06-2748

12 Electrical connection

Page 49: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

12.2 Connection box, double doors

Rebuilding of Master Connection box into Slave Connection Box

Only one power switch is needed to operate two units. Discard the extra switch and use the extrapower wires found in cable (1) to route power between connection boxes.

Leave the black/white/green wires accessible for the electrician in the box tied to the Mastercontrol.

a Remove the covers from both connection boxes.

b Cut off the Rocker Switch cable (1) close to the switch on the unit intended to be the slave.The Bottom end plate (2) is now obsolete material and is not used in the installation.

c Cut off the black wire (3) close to where it exits the cable (1), careful not to nick other wires.This wire will not be used.

d Connect the three green wires using a wire nut (4).

e Connect the two white wires using another wire nut (5).

f Adjust all wires neatly into box and reinstall the cover on the Slave box.

4

2

1

35

Slave

Power inlet

not used

Assemble Slave Connection box to Master Connection box

g Remove the knock-out plate of the unused entry (15) in the Master connection box.

h Insert the cut cable (1) through the new hole. Mount a strain relief (6) around the cable andlet it snap into the connection box wall leaving at least 4” of extra cable in the box.

i Cut the red wire in the Master box, leaving equal legs, and connect the three red wire endswith a wire nut (7).

49Issue 2012-06-271007718-US-3.0

12 Electrical connection

Page 50: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

j Cut off the white (8) and the green (9) wires from the Rocker Switch cable (10), beingcareful not to nick other wires.

k Strip the white (11) and the green (12) wires from cable (1). Leave these two wires uncon-nected and cut off the remaining black wire (17) from cable (1).

l Only the following wires should now be unconnected;- white wires (11) + (16) and green earth wires (12) + (14) + (18)- black wire (13) from the Rocker Switch cable

m See Installation Manual (1007718), chapter Electrical Connection, section Connection box,how to connect the mains power supply cable to the Master Connection box.

n Place the wires in the Master Connection box. Fasten the covers on both Connection boxesand connect the Interconnection cables to the control unit.

1

10

MasterSlave

Mains power

7

13

14

11

12

6

9

19

Cut the black wire

16

15

18

17

8

Ele

ctric

ian

No

tic

e!

Main

s P

ow

er

behin

d this

cover.

Connect to

White (

Neutr

al), B

lack

(HO

T),

Gre

en (

GN

D)

Do n

ot connect to

RE

D.

Note: Connect the sync cable (Kit No. 1008552) in between the two control units and applyan ”Electrician Notice” label (19) to the cover of the Master mains power connection box.

Electrician Notice!

Mains Power behind this cover.

Connect to White (Neutral), Black

(HOT), Green (GND)

Do not connect to RED.

19

Tip: For convenience tape together 1” from the ends of the following wire combinations inthe Master mains power connection box: Whites (11) + (16), Greens (12) + (14) + (18),Black should be a single wire.

1007718-US-3.0Issue 2012-06-2750

12 Electrical connection

Page 51: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

12.3 How to route the cables

51Issue 2012-06-271007718-US-3.0

12 Electrical connection

Page 52: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

12.4 Control units

12.4.1 CU-200The CU-200 can be equipped with extension units, EXU-SI and/or EXU-SA, depending on thefunctions required, see page 55 or 56.

12

34

56

PAG

MAT

SOS

AS1

AS2

AS3

AS4

1ON 2

34

56

7

OPD

LRN

GND

IIMP

XIMP

OPD

LOUT

+24V DC

SPTE OPSP CLSP CLTQPOAS HOT

LED

KHOT

8

AD

HOT / KHOT

5 s

1.5 s 30 s

CLSP

7 s

12 s 4 s

OPSP

5 s

12 s 2 s

PBO

LED

KICK

EncoderMotor

Synchronizing of double doors

ON/OFF/HOLD open switch

Lock-out for OPD/OPS (–)/OPS Overhead presence detection/Mat safetyInner impulse controlled byInner impulse

(-) 0 VDC Ground

/OPS Overhead presence detection/Overheadpresence sensor (incl. 24 V, LOUT and SafetyImpulse)

Hold open time

DIP-switches shown inOFF position

Closing torque

Power assistClosing speed

Opening speedSpring tension

PAGMATSOSAD

PUSH & GOSafety mat*Stop on stall(Activation Delay) 2s

External indicator

Key hold open time

Learn button

Panic breakout

**

**

(+) 24 VDC

After changing MAT dip switch a new LEARN must be carried out.*With heavier doors the time will increase.**

1007718-US-3.0Issue 2012-06-2752

12 Electrical connection

scott
Sticky Note
factory style little jumper fits on here perfectly.
Page 53: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

12.4.2 Arm system selectionFactory set arm configuration is PUSH 8 1/4" (210 mm), if other is required:

Select arm configuration on the DIP-switches according to the table below.

ON=1 OFF=0Spindle location (hinge to outgoing spindle)Type of arm system AS 4

DIP 8AS 3DIP 7

AS 2DIP 6

AS 1DIP 5

0000PUSH, 8 1/4" (210 mm)Pushing

0001PUSH, 3 3/4" (95 mm)Pushing

0010PUSH, 2 3/4" (70 mm)Pushing

0011

0100

0101

0110

0111Concealed (Outswing)

1000PULL, 8 1/4" (210 mm) Reveal 0" - 2 9/16" (0-65 mm)Pulling PULL

1001PULL, 8 1/4" (210 mm) Reveal 2 9/16" - 5 1/8" (65-130 mm)Pulling PULL

1010PULL, 3 3/4" (95 mm) Reveal 0" - 2 9/16" (0-65 mm)PULL, 2 3/4" (70 mm) Reveal 0" - 2 9/16" (0-65 mm)

Pulling PULL/PAS

1011PULL, 3 3/4" (95 mm) Reveal 2 9/16" - 5 1/8" (65-130 mm)PULL, 2 3/4" (70 mm) Reveal 2 9/16" - 5 1/8" (65-130 mm)

Pulling PULL/PAS

1100

1101PULL 210, 8 1/4" (210 mm)Distance (Reveal + Door thickness + hinge) = 75-130 mm

Sliding push

1110PULL 95, 3 3/4" (95 mm)Distance (Reveal + Door thickness + hinge) = 0-80 mm

Sliding push/Offset pivot

1111-Concealed (Inswing)

Note: The Panic Break Out Switch, shall be a normally closed contact, and is only needed atthe Concealed inswing application.

Note: After changing any system selection a new LEARN must be carried out.

53Issue 2012-06-271007718-US-3.0

12 Electrical connection

Page 54: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

12.4.3 Extension units EXU-SI / EXU-SA

InstallationTo extend the functions, the extension units can be mounted on top of the control unit CU-200,separately or combined.

EXU-SA

EXU-SI

CU-200

5 mm nut driver

Torx T10

Electrical power contact

Tag striplong 2 pcs EXUshort 1 pc EXU

Note: After changing/replacing an extension unit a new LEARN must be carried out.

1007718-US-3.0Issue 2012-06-2754

12 Electrical connection

Page 55: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

12.4.4 Extension unit EXU-SI

FunctionsThis extension unit has inputs for electro-mechanical lock, program selector, batteries, KILLfunction, OPEN/CLOSE, KEY opening and outer impulse.

12

345678910111213

1

ON

2 3 4 5

+24 V DC

OPEN

EXIT

OFF

UNL

KRST

KILL

KEY

O/C

OIMP

GND

+

1

ON

2 3 4 5

0.5 s

0 s 3 s

Program selector

Unlocked signal from lock

KILL reset (see jumper below)

KILL impluse

Key impluse (1.5-30 s)

OPEN / CLOSE impulse (latching relay)

Outer impulse

Ground

Electro-mechanical locking device (12V DC max. 1200 mA/ 24 V DC max 600 mA, see DIP-switch No. 1 below)

Potentiometer for opening delay 2)

Manual kill reset (jumper off)

Automatic kill reset (jumper on)

Battery monitoring

Lock release 2)

Locked without power (OFF) / with power (ON)*

Lock 12 V (OFF) / 24 V (ON)*

DIP-switches shownin OFF position

Lock kick1)

(-) 0 VDC Ground

(+) 24 VDC

Independent of switch position (ON /OFF), the “latch check” complies with the ANSI 156.19 requirements.Position OFF: Smooth closing, to be used on doors without lock.Position ON: More powerful closing, to be used on doors with lock, to overcome binding in the locking device.

1)

If the switch is set to ON, the LOCKRELEASE is active during the opening delay time set by the potentiometer.For PAIR OF DOORS installations, the LOCK RELEASE works in sequence: First the MASTER then theSLAVE.

2)

Note: Lock only functions when Program Selector is in OFF or EXIT.

After changing any system selection a new LEARN must be carried out.*

55Issue 2012-06-271007718-US-3.0

12 Electrical connection

Page 56: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

12.4.5 Extension unit EXU-SAThis extension unit has inputs for door mounted sensors, which can give presence impulse onapproach side and/or presence detection on swing path side. Relay output for error indicationor door indication is also integrated.

Functions

678

12345

NO

COM

NC

24 V DC

QTST

PDET

PIMP

GND

Monitoring of presence detection/DMPS.SS

Monitoring of presence impulse/DMPS.NS

No monitoring (both jumpers on)

Monitoring of presence detection and presence impulse

External error indication / KILL OUT / Lock

Open door indication / closed doorindication

Relay output (“External error, KILL OUT, Lockindication” or “Open/closed door indication”, seeabove) 24 V, 1 A

DMPS monitoring and reference for KILL (NC)

Presence detection (NC)/DMPS.SS1)

Presence impulse (NC)/DMPS.NS1)

Ground

Remove strapping when connecting toterminals 2 and/or 3

Blanking potentiometer(Adjust the potentiometer to avoid presence detection sensor todetect the wall. Range 55 - 90 degrees.)Closed door indication / open door indication

Blanking LED

1) If not used strap to “Ground”.2) Remove strapping from terminals 2 and/or 3.

Door mounted sensors2)

DMPS:Relay 1: Presence impulse (NC)Relay 2: Presence detection (NC)

(-) 0 VDC Ground

(+) 24 VDC

1007718-US-3.0Issue 2012-06-2756

12 Electrical connection

scott
Sticky Note
have jumper on the right pins for door mounted safety side sensors -
scott
Sticky Note
push door open to point where door stalls - adjust pot until the "blanking LED" comes on - adjust from there -
Page 57: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

12.4.6 How to cut the jumper on the sync cable for double doors

Note: Connect a cable between Master CU TB1(GND) and Slave CU TB1(GND).

MASTER SLAVE

RedBlack

Cut the jumper with colorDoor designFunction

SLAVE sideMASTER sideJam-ming

AstragalClosingOpening

No cuttingNo cuttingNoNoSynchronousSynchronousNo cuttingCut blackNoYesAsynchronousSynchronousCut redNo cuttingYesYesAsynchronousAsynchronousCut redCut black——Double egress

Astragal Jamming No jamming

Also see page 21.

12.4.7 Settings for double doorsSettings on the

FunctionSLAVEMASTER

CommonXProgram selectionXOpening timeXClosing timeXHold open timeXClose / Continue to open when the door is obstructedXPAG On/OffXSOS On/Off

(X)*XLevel of Power assist(X)*XExtended closing torque

XOPD/OPS Impulse or Mat Logic ImpulseIndividual

XXLock/Unlock signal voltageXXLocked without/with powerXXLock release Enable/DisableXXOpen Delay TimeXXLock kick Enable/Disable

57Issue 2012-06-271007718-US-3.0

12 Electrical connection

Page 58: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

* For “Double egress doors”, these functions must be set separately for MASTER and SLAVEas the arm systems as well as the air pressure may be different.

Note:

• Locks on the MASTER and SLAVE doors must be connected to the control unit (CU) onthe corresponding operator.

• Inner and outer impulses can be connected to either MASTER or SLAVE CU or both.

• The OPD/OPS is to be connected to the MASTER CU except for “Double egress”, whereeach OPD/OPS must be connected to corresponding CU.

• Door leaf mounted sensors must always be connected to corresponding CU.

1007718-US-3.0Issue 2012-06-2758

12 Electrical connection

Page 59: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

13 Start-up

The spring pre-tension is factory set to 360° and is normally not necessary to adjust. If adjust-ment has to be carried out, see “Reducing / Increasing the “Spring pre-tension” (SPTE)” onpage 68.

Check and adjust the micro switch (1), controlling the lock kick, by turning the black plasticcam (2) when power is off.

2

1

13.1 Adjusting the door stop

a Close the door.

b Turn the potentiometer SPTE to 0° (if not already on 0°).

c Switch on the electrical power (the operator will find its closed position) and make sure theLED is on.

00

59Issue 2012-06-271007718-US-3.0

13 Start-up

Page 60: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

d Open the door to required open position, plus approx. 5/8” (15 mm), by turning the poten-tiometer SPTE on the CU-200, clockwise.

SPTE ≈ 95°

e When stop arm is on top of the operator, lift the door stop arm up and mount it on the splines,as close as possible to the stop block 1). Fine-adjust if necessary with the screw on the stoparm 2).

1) 2)

f When stop arm is on the bottom of the operator, loosen the stop ring and the stop arm.Mountthe stop arm on the splines, as close as possible to the stop block 3). Mount the stop ring.Fine-adjust if necessary with the screw on the stop arm 4).

3) 4)

g Close the door by turning the potentiometer SPTE to 0° and let the door close.

1007718-US-3.0Issue 2012-06-2760

13 Start-up

Page 61: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Note: Impulses are not accepted if SPTE is more than 0°.

SPTE

1

3

2

Door stop arm1Stop block2Fine-adjustment screw3

61Issue 2012-06-271007718-US-3.0

13 Start-up

Page 62: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

13.2 Auto-learn – automatically sets back and latch check (recommended)

This learning is performed by pushing the LEARN BUTTON (LRN).

• Before the learning procedure starts, make sure that the door has been properly closed i.e.,not by force.

• A new learn must be carried out in following situations

- If any of the parameters SPRING PRE-TENSION, CLOSING TORQUE (CLTQ) andLOCK RELEASE (DIP-switch No. 3 on EXU-SI) are changed after performing a learn.

- If any of the arm system DIP-switches are changed.

- If any changing of the MAT-dip.

- When replacing any of the extension units.

- When changing of Locked with/without power.

- When changing of Lock 12/24 V.

• Learn can be carried out with activation units and locks connected.

• The back-check will be automatically adjusted to 10° and 1 second before open position.The latch-check will be automatically adjusted to 10° and 1.5 seconds before closed position.

10°/1 s

10°1.5 s

Back-check Latch-check

13.2.1 Push the LEARN BUTTON (LRN)

Remain clear of swing path of door, as door may open and close rapidly.The door has no safety during auto-learn cycle.

When the learn button is pressed the status LED starts to blink and will not stop until learn isconcluded.

Note: Do not touch the door during the auto-learn cycle.

The learn cycle starts with sensor detection, during which the door will stand still. When thedoor starts moving the spring tension and door inertia are measured and the door open and closeposition is saved. When the learn is concluded the back-check, latch-check, opening time andclosing time are calculated. The changed settings affect the behavior of the installation andmustbe verified.

LRN

PAG

MAT

1ON 2

3

CLTQPOAS HOT KHOT

1007718-US-3.0Issue 2012-06-2762

13 Start-up

Page 63: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

13.2.2 Double doorsFor double doors, the MASTER door must be learned first and thereafter the SLAVE door.When the SLAVE door is learned, theMASTER door will open up to fully open position duringthe learning phase of the SLAVE door.

The doors can also be learned separately before connecting the sync cable. In case of astragaldoors and separate learning, the MASTER door must be held open before the SLAVE doorlearn is carried out.

13.3 General adjustment

a Set the hold open time with the potentiometer on the control unit.

b Adjust the opening speed (OPSP) to complywith ANSIA156.19. Turning clockwise increasesthe speed (see Table I on page 79).

c Adjust the closing speed (CLSP) to comply with ANSI A156.19. Turning counter- clockwisedecreases the speed (see Table I on page 79).

d Connect the required activation units.

e Check that the installation complies with AHJ (Authority Having Jurisdiction).

63Issue 2012-06-271007718-US-3.0

13 Start-up

Page 64: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

13.4 Connection of activation units and accessories

Push

plate

OPD/OPS

Activation

sensor

1

4

CU-200

CU-200

EXU-SI

CU-200

EXU-SA

CU-200

EXU-SA

EXU-SI

EXU-SI

5

6

2

3

EXU-SI 7

PRESSTO OPEN

6 1 21 2

3

6 1 4 5

(6 1 3)*

13 3 4

5 1 2

6 1 4 5

3 10

1 3

3 6

3 4

3 7

4

7

3 101112

PIM

P/D

MP

S.N

S (

NC

)P

DE

T/D

MP

S.S

S (

NC

)

(+)

24

VD

C

IMP

UL

SE

(N

O)

LO

UT1 2 3 4 5

PS-4C

Kill

switches

With monitoring

DMPS

(+)

24

VD

C(-

) 0

VD

C

IMP

UL

SE

(N

O)

(-)

0 V

DC

(+)

24

VD

C

(-)

0 V

DC

MO

NIT

OR

ING

5 1 4

4

(-)

0 V

DC

(C

OM

)

1

1

Timer

Door mounted

Inner impulse1

Outer impulse2

Key impulse3

Presence impulse/DMPS.NS4

Presence detection/DMPS.SS5

Off6

Kill impulse7

Standard*

Note: According to local standard UL325 56 2.2, push plates shall be visible from the door.

1007718-US-3.0Issue 2012-06-2764

13 Start-up

Page 65: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

14 Changing group of parameters

a Disconnect the electrical power contact.

b Press the LEARN BUTTON (LRN) and keep it depressed.

c Connect the electrical power contact.

d Watch the ERROR LED.3 s 5 s1 s

e Release the LEARN BUTTON after the 5 seconds (LED is out).The ERROR LED flashes a number of short flashes that corresponds to the parameter groupnumber (see table). After a short pause the LED will repeat the group number, and so on.

f Pushing the LEARN BUTTON once, increases the parameter group number. When thehighest parameter group number is reached it will start with number 1 (default) again.

g Push the button until you get the requested parameter group.

h Disconnect the electrical power contact.

i Next time the electrical power is connected, the operator will use the new group of parameters.

65Issue 2012-06-271007718-US-3.0

14 Changing group of parameters

Page 66: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

1615

1413

1211

109

87

65

43

21(defau

lt)Pa

rameter/G

roup

Infin

iteInfin

ite15

minutes

15minutes

15minutes

15minutes

15minutes

15minutes

15minutes

15minutes

15minutes

15minutes

15minutes

15minutes

Infin

ite15

minutes

OPE

N/CLOSE

HOLDOPE

NTIM

E

Locked

durin

gKILL

Locked

durin

gKILL

Unocked

durin

gKILL

Locked

dur-

ingKILL

Unocked

dur-

ingKILL

Unocked

dur-

ingKILL

Locked

dur-

ingKILL

Lock

follo

ws

programselec

-tord

uring

KILL*

Locked

dur-

ingKILL

Locked

dur-

ingKILL

Locked

dur-

ingKILL

Locked

dur-

ingKILL

Lock

follo

ws

programselec

-tord

uring

KILL

Locked

dur-

ingKILL

Locked

dur-

ingKILL

Locked

dur-

ingKILL

KIL

Lmod

e

Reverses

whenob-

structed

Reverses

whenob-

structed

Doorc

loser

Doorc

loser

Doorc

loser

Doorc

loser

Reverses

wheno

bstru

ct-ed

Doorc

loser

Doorc

loser

Doorc

loser

Doorc

loser

Reverses

wheno

bstru

ct-ed

Doorc

loser

Doorc

loser

Doorc

loser

Doorc

loser

OBST

RUCTIO

Nmod

e1)

Separate

presence

detection

Separate

presence

detection

Separate

presence

de-

tection

Separatepres-

ence

detec-

tion

Separatepres-

ence

detec-

tion

Separatepres-

ence

detec-

tion

Separatepres-

ence

detec-

tion

Separatepres-

ence

detec-

tion

Separatepres-

ence

detec-

tion

Separatepres-

ence

detec-

tion

Com

mon

presence

de-

tection**

Separatepres-

ence

detec-

tion

Separatepres-

ence

detec-

tion

Separatepres-

ence

detec-

tion

Separate

presence

de-

tection

Separate

presence

de-

tection

DOUBLE

EGRESS

mod

e

On

On

On

On

On

On

On

On

On

Off

On

On

On

On

On

On

LOCK

RETRY

InOFF

,EX

ITand

InOFF

,EX

ITand

InAUTO

mode

InAUTO

mode

InAUTO

mode

InAUTO

mode

InAUTO

mode

InAUTO

mode

InOFF

,EXIT

andAUTO

mode

InAUTO

mode

InAUTO

mode

InAUTO

mode

InAUTO

mode

InAUTO

mode

InAUTO

mode

InAUTO

mode

OPE

N/CLOSE

impu

lse

AUTO

mode

AUTO

mode

Normally

Closed

Normally

Open

Normally

Closed

Normally

Closed

Normally

Closed

Normally

Open

Normally

Open

Normally

Closed

Normally

Open

Normally

Open

Normally

Open

Normally

Open

Normally

Open

Normally

Open

Normally

Open

Normally

Open

KIL

LIm

pulse

Con

figuration

Monito

red

Monito

red

Monito

red

Monito

red

Monito

red

Lock

Lock

Lock

KILLo

utKILLo

utKILLo

utErrorindica-

tion

Errorindica-

tion

Errorindica-

tion

Errorindica-

tion

Errorindica-

tion

Errorindica-

tion

Errorindica-

tion

Errorindica-

tion

Errorindica-

tion

Errorindica-

tion

Relay

*Th

elock

unlocksa

timpu

lsedu

ringKILLin

EXIT

mode.

**Please

consider

thatuseof

Push

And

Gotogether

with

Com

mon

presence

detectionmay

causestop

intra

fficflo

w.

1)IfsettoREV

ERSE

SWHEN

OBST

RUCTE

D,the

operator

re-opens

whenobstructed,sim

ilartoapresence

impulse.

Inthedefaultsettin

g,ifthereisabind

with

thestrik

eplatewhenthedoor

isclosingthedoor

will

tryto

closetw

oextra

times

inautomaticoperation,OFF

orEX

ITmodeandonce

extra

inmanual

operation.

Thisfunctio

ncanbe

switc

hedoff(see“L

ockretry

”above).

Note:Whenchanging

grou

pof

parameters,no

rmally

only

themastercontro

lmustb

econfigured

inadoubledoor

application.Whenchanging

from

orto

groupseven,both

MAST

ERandSL

AVE

mustb

econfigured.

1007718-US-3.0Issue 2012-06-2766

14 Changing group of parameters

Page 67: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

14.1 Learn with advanced setting of “back- and latch-check”

See the prerequisites for performing a “learn” under the heading “Auto-learn – automaticallysets back and latch check (recommended)” on page 62.

a Push the button once or twice as for auto-setting.

b Stop the door at the fully open position.

c The door reverts towards closed position.

d Stop the door at required latch-check.

e The door reverts to the open position.

f Stop the door at the required back check.

g Remove the stop.

h The door reverts to closed position.

14.2 Revert to default values for “back- and latch-check”

a Disconnect the electrical power contact.

b Press the LEARN BUTTON and keep it depressed.

c Connect the electrical power contact.

d Watch the ERROR LED.3 s

e Release the LEARN BUTTON after 3 seconds (LED is out).

f The BACK CHECK, LATCH CHECK and OPEN POSITION have now reverted to defaultvalues.

g Disconnect the electrical power contact.

h Next time the electrical power is connected, the operator will use the default values.

67Issue 2012-06-271007718-US-3.0

14 Changing group of parameters

Page 68: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

14.3 Reducing / Increasing the “Spring pre-tension” (SPTE)

The spring pre-tension is factory set to 360° and is normally not necessary to adjust. If adjust-ment has to be carried out, the electrical power must be switched on during spring pretentionand learn, see below.

Make sure the potentiometers "Extended closing torque" (CLTQ) and "Power assist" (POAS)are set to 0°.

a Loosen the door stop arm. Remove if fitted on the topside, slide down if fitted on the bottom.

b Turn the potentiometer for spring pre-tension (SPTE) clockwise until the door opens to 45°.

c Loosen the drive arm fixing screw.

d Moving the door towards open position, reduces the tension, or:Moving the door towards closed position, increases the tension.

e Tighten the drive arm.

f Turn the potentiometer SPTE to 0°.

g Open the door to required open position, plus approx. 15 mm (5/8"), by turning the poten-tiometer SPTE clockwise.

h Mount the door stop arm as close as possible to the open door stop block, fine- adjust withthe screw if necessary.

i Turn the potentiometer SPTE to 0°.

j Push the LEARN BUTTON.

k Let the door do the learn cycle without touching it.

Note:Max. allowable spring pre-tension is 720°. Over-tension may damage the spring oroverheat the motor.

210°

SPTE

180°

90°

1007718-US-3.0Issue 2012-06-2768

14 Changing group of parameters

Page 69: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

15 Classification

15.1 Entering the program mode (classification)

On the master control unit.

• Disconnect the mains plug

• Press the LEARN BUTTON while connecting the mains plug

• Watch the ERROR LED3 s 5 s1 s 5 s1 s

• Release the LEARN BUTTON after the second 5 s has passed

15.2 Identify the current classification

The ERROR LED flashes an amount of short flashes that correspond to the classificationnumber.

After a short pause the LED will repeated the classification number and so on.

15.3 Changing the classification

If you push the LEARN BUTTON once, the classification number will increase. When youhave reached the highest classification number it will start at number one again.

• Push the button until you get the requested classification

• Disconnect the mains plug

Next time you connect the mains the operator will use the new classification.

15.4 Classification table

21Classification

Low energy (Default)Full power

ANSI 156.19 (and DIN 18650-2)ANSI 156.10StandardAutomatic limitation, 3-12 s2-12 sOpening speedAutomatic limitation, 4-12 s4-12 sClosing speed

The fastest setting of Opening Speed and Closing Speed are automatically limited to the valuein the table, and can only be reduced.

If the LowEnergy classification is used the operator will automatically follow the speed limitationin ANSI 156.19 (and DIN 18650-2).

The learn procedure must be carried out after a change of the classification setting.

Speed settings according to Table I inANSI / BHMAA156.19 (LOWENERGYAPPLICATION)

69Issue 2012-06-271007718-US-3.0

15 Classification

Page 70: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

16 Cover

The cover and back plate are manufactured in clear anodized aluminium. The end plates aremade of black painted steel sheet.

16.1 Creating slot in the cover for the drive shaft

a Measure the distance X on the mounted operator from the pivot end of the back plate to thecenter line of the output shaft.

b Use a 1 1/4 ” (31,75 mm) hole saw to cut the round hole for the output shaft.

c Use a hack saw to make two straight cuts.

X

11/4"

LC

2 1

/4"

= Output shaft, center line

16.2 Fitting and removing the cover

The cover is slid over flanges in the back plate so that the ridges fit in the grooves. Snap on thefill cover into the slot for output shaft. Secure cover with screws.Apply the Besam logotype to the cover – see below.Apply the product label to the underside of the cover – see below.

1007718-US-3.0Issue 2012-06-2770

16 Cover

Page 71: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

17 Troubleshooting

Remedies/ExplanationsPossible reasons whyFault

Change the setting of the control switchControl switch is set to OFFThe door does not openThe motor does not start Check the electrical power power switchElectrical power power is missing

Strap impulse inputsActivation unit does not functionCheck that there are no objects in the detectionzone

Presence detection is activated

Deactivate KILLKILL activatedTurn SPTE to 0°Potentiometer SPTE not turned to 0°Unlock the lockMechanical lock is lockedThe motor startsRemove objectSomething jammed beneath the doorSelect lock releaseElectric striking plate is bindingAdjust strikingTurn potentiometer SPTE until the door-stop hitsthe stop-block. Put the door in required open posi-tion. Tighten the arm system. Turn SPTE to 0°

Arm system has come loose

Change the setting of the ON/OFF/HOLD openswitch

Control switch is set to HOLDThe door does not close

Remove objects in the detection zonePresence impulse is activatedRemove objectSomething jammed beneath the door

a Turn up the potentiometer SPTE until it ispossible to loosen the door arm stop

b Remove the door stop and the arm system

c Unplug the electrical power and let spring close

d Unplug the motor plug

e Mount the drive arm from the arm system andfind the 0 pre-tension bymoving back and forth

f Loosen the arm

g Connect the motor plug

h * Turn the SPTE pot to 180° and wait until thespindle stops turning

i Connect the electrical power. The operator willnow tension the spring to factory set 720°

j Mount the door stop against the closing stopblock

k Turn down SPTE to 0º - operator is now factoryset

l Turn to section 12 to adjust open stop position

Too many adjustments carried outThe operator has un-known spring pre-ten-sion

* Adjusting the SPTE before power up increase the SPTE range 4 times i.e. 180° on the SPTEwill tension the spring 2 turns = 720°. Adjusting to zero during power on will reset range ofSPTE.

71Issue 2012-06-271007718-US-3.0

17 Troubleshooting

Page 72: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

17.1 Error indication

• During normal operation the ERROR LED on the control unit is illuminated.

• An extinguished LED indicates that there is no electrical power power.

• A flashing light on the LED indicates that the operator is out of function (see table below).

• An audible warning signal can be achieved by using the accessory board AIU. It is connectedto the 24 VDC and plugged into the EXU-SA relay output terminal.

RemedyReasonLED flash frequency

Make a kill reset, reset kill switch or reset firealarm

Kill impulse is activeOne 0.3 s flash, 10 s pauseetc.

Check for short circuit+ 24 V DC external errorOne 0.3 s flash, 2 s pauseetc.

Check for broken monitored sensorSensor monitoring errorOne 0.3 s flash, 2 s pauseetc.

Replace control unitControl unit defectiveThree 0.3 s flashes, pauseetc.

Check the encoder cable.Encoder errorFour 0.3 s flashes, pause etc.Open and close the door manually and thereaftercheck the automatic function. If the operator isstill out of function replace the drive unit.Check for e.g. short circuit in the locking deviceLocking device defectiveFive 0.3 s flashes, pause etc.Replace locking deviceReplace EXU-SI boardEXU-SI board defectiveConnect the sync cableSync cable not connected or

defective (double door only)Six 0.3 s flashes, pause etc.

Replace the sync cableCheck the flash frequency on the SLAVE LEDand take necessary measures in accordance withthis table.

SLAVE control unit defec-tive (double door only)

Seven 0.3 s flashes, pauseetc.

Wait for the motor to cool downMotor overheatedEight 0.3 s flashes, pauseetc.

Toggle impulseBlocked door and constantimpulse.

Nine 0.3 s flashes, pause etc.

Check set up.Settings have been madethat requires a new learn orthe learn has failed.

Ten flashesMake a new learn.

1007718-US-3.0Issue 2012-06-2772

17 Troubleshooting

Page 73: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

18 Maintenance plan

Regular inspections shall be made according to national regulations by a trained and qualifiedperson. The number of service occasions shall be in accordance with national requirements.This is especially important when the installation concerns a fire-approved door or a door withan emergency opening function. Refer to Besam Pro-Active Care option services to learn moreabout service possibilities!

As with all other technical products, an automatic door needs maintenance and service. It isessential to know the importance of maintenance to have a reliable and safe product.

Service and adjustments will ensure a safe and proper operation of an automatic door unit.

The table below shows the recommended interval, in months, when to replace parts duringpreventive maintenance.

Abusive

Environ-ment

Cycles/hour in operationPart numberPart

>100<100<10

Hightraffic

Mediumtraffic

Lowtraffic

661224330000271 SI/BKPUSH arm service kit661224330000272 SI/BKPULL arm service kit661224330000276Stop arm kit661224330000275Micro switch kit661224330000270Adaptor kit60606060331007291Transmission unit60606060331007504 BKConnection box kit60606060331008346Control unit CU-200with EXU-

boards

73Issue 2012-06-271007718-US-3.0

18 Maintenance plan

Page 74: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

19 ANSI / BHMA A156.10

19.1 REQUIREMENTS FOR POWER OPERATED DOORS

From American National Standard for Power-Operated Pedestrian Doors. Please refer to thefull standard if necessary, obtainable through BHMA at (212) 661-4261. All figures referredto below can be found in the full standard. Excerpts reprinted with BHMA permission.

19.1.1 Swinging DoorsAutomatic Swing Doors have a variety of configurations, including:

• A single door swinging in or out, left-handed or right handed

• A pair of doors simultaneously swinging in the same direction

• A pair of doors simultaneously swinging in opposite directions (double egress)

The door operator is concealed or surface applied. The doors are center pivoted, offset hung,balanced or butt hinged. No matter what the configuration or system, automatic swinging doorsshall include guide rails, sensors or control mats and signage for the safety and convenience ofthe user.

6. Guide Rails6.1.1 Two guide rails shall be installed on the swing side of each door. Single doors shall haveone on each side of the door and pairs or double egress shall have one rail on each hinge side.Rails shall project to the leading edge of the widest door in the open position.

Exception #1: A wall or separator is permitted to be used in place of a rail, provided that itmeets the criteria in 6.2.1 through 6.1.5

Exception #2: Guide rails for swing doors serving both egress and ingress shall project outfrom the face of the door jambs on the swing side to no less than the outside leading edge ofthe open door plus 55 in.

Exception #3: If double egress doors or a pair of doors is installed in a hallway, no guide railsare required if the distance between the wall and the door in the 90 degree open position doesnot exceed 10 in.

Exception #4: Guide rails for Knowing Act swinging doors serving both egress and ingressshall project out from the face of the doorjambs on the swing side to no less than the outsideleading edge of the open door plus 12 in.

6.1.2 A guide rail shall be 30 in. high minimum measured from the floor surface.

6.1.3 A guide rail shall have a panel or divider to inhibit access to the protected area.

6.1.4 There shall be 6 in. minimum clearance between the rail and the door in the fully openposition or between the rail and the leading edge of the door at the point in its arc of travel whenit is closest to the rail. There shall be a 2 in. minimum clearance between the rail at the hingeside and the door in the fully open position.

6.1.5 Free standing guide rails shall have a maximum dimension between the rail and the jamb(or other adjacent surfaces) of 6 in.

For control mat adjustments, see full standard.

8. Sensors8.1 General Requirements for Sensors

1007718-US-3.0Issue 2012-06-2774

19 ANSI / BHMA A156.10

Page 75: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

8.1.1 Activating zones for swinging, sliding and folding doors shall have a minimum widthequal to the width of the clear opening measured at 8 in. and 30 in. perpendicular from the faceof the closed door(s). The length from the face of the door shall be 43 in. minimum measuredat the center of the clear opening. Detection shall be effective to within 5 in. from the face ofthe door measured at the center of the clear opening. Exception: If the 43" activating zone lengthis not practical due to physical or environmental conditions, it shall be permissible to be reducedto 30 inches, along with an additional sign, visible from the side the zone has been reduced on,stating "AUTOMATIC CAUTION DOOR" as described in 11.2.3.

8.1.2 Motion sensors shall detect a 28 in. minimum high person, moving at a rate of 6 in. persecond minimum toward the center of the door within the detection zone described.

8.1.3 Presence sensors shall detect a stationary 28 in. minimum high person within the detectionareas described for a minimum of 30 sec.

8.2 Swinging Doors

8.2.1 Swinging doors shall have an activating zone as described in 8.1.1.

8.2.2 A safety zone shall be provided on the swing side of all power operated swinging doors.

8.2.2.1 If an overhead presence sensor(s) is used to provide a safety zone, the length of the activearea shall be effective to within 5 in. of the face of the closed door measured at the center ofthe door opening. The safety zone shall extend 5 in. minimum beyond the leading edge of thedoor in the open position when measured at the center of the door opening. The width of theactive area measured perpendicular from the face of the closed door shall be the door openingless 5 in. maXcimum measuring both sides for a total of lOin. maXcimum measured parallelto the face of the door at a distance of 8 in. and 30 in. When the safety zone is occupied by a28 in. minimum high person fully in the safety zone of a fully open or closed door, the dooroperator shall not operate.

8.2.2.2 When an overhead presence sensor on the swing side is prevented from providing asafety signal to the control during the closing cycle, an additional sensor, sensors, or photo beamshall be used on the swing side to

1) stop the door, or

2) continue to close the door, or

3) slow the reopening door to a maximum latch edge speed of 4 in. per second measured within1 in. of the latch edge before any contact is made.

8.2.2.2.1 When using a photo beam, the detection width shall be not less than the clear opening;the beam shall be located between 6 and 28 in. above the finish floor, and not more than 8 in.from the lead edge of the door panel in the full open position.

8.2.2.2.2 When using a door mounted presence sensor, the detection area shall be effective towithin 5 in. from the face of the door, for one half of the width of the door, and to within 1 in.of the lead edge, and shall detect a 28 in. minimum high person fully in the defined area.

8.2.2.3 If a door mounted presence sensor is used to provide a safety zone, it shall be effectiveto within 5 in. from the face of the door for the width of the door less 5 in from the pivot pointand to within 1 in. of the lead edge. A door mounted sensor on either side of the door shall detecta 28 in. minimum high person fully in the swing path, during the opening or closing cycle andshall cause the door to reverse direction, stop or slow down to a maximum latch edge speed of4 inches per second measured within 1 in. of the latch edge before any contact is made.

8.2.3 Swinging doors serving both egress and ingress, including non-knowing act double egressdoors, shall have on the swing side, a safety zone as defined in 8.2.2, and an activating zone.The length of the activating zone shall be established as follows: the activating zone starts adja-cent to the safety zone and extending an additional 55 in. from the leading edge of the door in

75Issue 2012-06-271007718-US-3.0

19 ANSI / BHMA A156.10

Page 76: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

the open position. The activating zone shall have a minimum width equal to the width of theclear opening measured at 8 in. and 30 in. from the interlace of the safety and activating zones.

8.2.5 When sensors are used to provide both an activating and a safety zone, if the distance be-tween the two non overlapping zones exceeds 8 in. the door system shall:

1) be equipped with a safety control mat; or

2) be equipped with a presence sensor across the door opening; or

3) have a door closing cycle delay of 4 seconds minimum after the activating zone is clear; or

4) be equipped with a door mounted presence sensor on the non swing side as described in8.2.2.3.

For knowing Act and double egress doors, see full standard Section 9.

10. Entrapment Protection10.2 Swinging Doors

10.2.1 The opening time of a swing door to 80 degrees shall not be less than 1.5 seconds

10.2.2 The force required to prevent a stopped power operated swinging door in the last 10 de-grees of opening from moving in the direction of opening shall not exceed 30 lbf (133 N)measured 1 in. from the lock edge of the door.

10.2.3 Back check shall occur at no less than 10 degrees of the full open position.

10.2.4 Swing doors utilizing sensors or control mats shall remain open aminimum of 1.5 secondsafter loss of detection unless otherwise specified in this standard.

10.2.5 A swing door shall be adjusted so that the closing times to latch shall be the minimumvalues in the following table:

TimeLbs. (kg)Inches (mm)

T (secs.)(W)(D)2.0to 100 (45)36 (914) & under2.3to 140 (64)36 (914)2.3to 110 (50)42 (1067)2.7to 150 (68)42 (1067)2.8to 120 (55)48 (1219)3.2to 160 (73)48 (1219)

For doors of other weights and widths:T = D √W /188 where:W = Weight of door in poundsD = Width of door in inchesT = Closing time to latch check in seconds

10.2.6 Latch Check shall occur for swinging doors at no less than 10 degrees from closed positionand the door shall not close through the final 10 degrees in less than 1.5 seconds.

10.2.7 The force required to prevent a stopped power operated swinging door from moving inthe direction of closing shall not exceed a 30 lbf (133 N) measured 1 in. from the lock edge ofthe door at any point in the closing cycle.

10.2.8 In the event of power failure, a swing door shall be capable of being opened manuallywith no greater than a 30 lbf (133 N), applied 1 in. from the edge of the lock stile to open.

1007718-US-3.0Issue 2012-06-2776

19 ANSI / BHMA A156.10

Page 77: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

10.2.9 Swinging doors provided with a break away device shall require no more than 50 lbf(222 N) applied 1 in. from the edge of the locks tile to open. When the door(s) is opened in thebreak out mode, powered operating components excluding spring power shall not operate thedoors.

10.2.10 The opening at hinge side of swinging door shall be: a) Less than ¼ in. wide with thedoor in any position, or b) At least ¾ in. wide with the door in any position. A door that doesnot comply with the above is acceptable if provided with a finger guard.

11. SignageConsistent with section 2.2.2 of ANSI Z535.4 the “signage and warnings” guidelines ofA156.10 are recognized, industry specific standards that predate the adoption of Z535.4and are not replaced by the standards set forth therein.

11.1 All Swinging, sliding and folding doors shall be equipped with signage visible fromboth sides reading “AUTOMATIC DOOR” with letters ½ in. high minimum. The signdescribed in figures B-1, B-3, and B-5 shall be permitted to be used to satisfy this require-ment.

11.2.1 An arrow sign shall be visible from the approach side of a swinging door mounted onthe door at a height of 58”+ 5 in. from the floor to the center line of the sign. The sign shall bea minimum of 6 in. in diameter, having a green circle surrounding a black arrow on a whitebackground.

ILL-02274

AUTOMATIC

DOOR

11.2.2 An International “DO NOT ENTER” sign shall be visible from the side of doors thatswings towards pedestrians attempting to travel in the wrong direction mounted on the door ata height 58”+ 5 in. from the floor to the center line of the sign. The sign shall be a minimum of6 in. in diameter, having a red circle with the wording, “DO NOT ENTER”, in the red circle.

ILL-02273

DO NOT

ENTER AUTOMATIC

DOOR

77Issue 2012-06-271007718-US-3.0

19 ANSI / BHMA A156.10

Page 78: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

11.2.3 Swinging doors serving both egress and ingress shall be marked with a decal visible fromthe swing side of the door, “AUTOMATIC CAUTION DOOR”. The sign shall be mounted onthe door at a height 58”+ 5 in. from the floor to the center line of the sign. The sign shall be aminimum of 6 in. in diameter and with black lettering on a yellow background.

ILL-02272

58

±5

"

CL

Apply to the approach side of the door.

AUTOMATIC

DOOR

75-20-100

DO NOT

ENTERAUTOMATIC

DOOR

AUTOMATIC

DOOR

CAUTION

75-20-102

AUTOMATIC

DOOR

CAUTION

75-20-102

DO NOT

ENTERAUTOMATIC

DOOR

AUTOMATIC

DOOR

75-20-100

A

B

C

Shall be visible from the side of doors that

swings towards pedestrians attempting to

travel in the wrong direction.

Apply on the swingside of the door.

1007718-US-3.0Issue 2012-06-2778

19 ANSI / BHMA A156.10

Page 79: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

20 ANSI / BHMA A156.19 (LOW ENERGYAPPLICATION)

20.1 REQUIREMENTS FOR POWER OPERATED DOORS

The following texts are excerpts from American National Standard for power-operated doors.Please refer to the full standard if necessary.

20.1.1 ActivationThe operator shall be activated by a knowing act.

20.1.2 OpeningDoors shall open from closed to back check, or 80 degrees which ever occurs first, in 3 secondsor longer as required in Table I. Backcheck shall not occur before 60 degrees opening. Totalopening time to 90 degrees shall be as in Table II. If the door opens more than 90 degrees, itshall continue at the same rate as backcheck speed. When powered open, the door shall remainat the open position for not less than 5 seconds.

20.1.3 ClosingDoors shall close from 90 degrees to 10 degrees in 3 seconds or longer as required in Table I.Doors shall close from 10 degrees to fully closed in not less than 1.5 seconds.

20.1.4 Force and Kinetic EnergyThe force required to prevent a stopped door from opening or closing shall not exceed 15 lbf(67 N) measured 1 in (25 mm) from the latch edge of the door at any point during opening orclosing.The kinetic energy of a door in motion shall not exceed 1.25 lbf-ft (1.69 Nm). Table I providesminimum times for various widths and weights of doors for obtaining results complying withthis kinetic energy.Doors shall open with a manual force not to exceed 15 lbf (67 N) to release a latch, if equippedwith a latch, 30 lbf (133 N) to set the door in motion, and 15 lbf (67 N) to fully open the door.The forces shall be applied at 1" (25 mm) from the latch edge of the door.

Table IMinimumOpening Time to Back Check or 80 degrees, which ever occurs first, and theMinimumClosing Time from 90 degrees to Latch Check or 10 degrees.

“W” Door Weight in Pounds (kg)“D” Door Leaf Width - Inches(mm)

200 (90.7)175 (79.4)150 (68.0)125 (56.7)100 (45.4)3.53.03.03.03.0*30 (762)4.04.03.53.53.036 (914)4.54.54.04.03.542 (1067)5.55.04.54.54.048 (1219)

* Check applicable Building Codes for clear width requirements in Means of Egress.

79Issue 2012-06-271007718-US-3.0

20 ANSI / BHMA A156.19 (LOW ENERGY APPLICATION)

Page 80: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Table IITotal Opening Time to 90 Degrees

Backcheck at 80 degreesBackcheck at 70 degreesBackcheck at 60 degrees

Table I plus 1secondTable I plus 1.5 secondsTable I plus 2 secondsIf the door opens more than 90 degrees, it shall continue at the same rate as backcheck speed.

Note: To determine maximum times from close to full open, the operator shall be adjusted asshown in the chart. Back check occurring at a point between positions in Table II shall use thelowest setting. For example, if the backcheck occurs at 75 degrees, the full open shall be thetime shown in Table I plus 1.5 seconds.

20.1.5 SignageDoors shall be equipped with signage visible from either side, instructing the user as to the op-eration and function of the door. The signs shall be mounted 50" +/- 12" (1270mm +/- 305mm)from the floor to the center line of the sign.The letters shall be 5/8 inch (16 mm) high minimum.

Doors All doors shall be marked with signage visible from both sides of the door, with thewords “AUTOMATICCAUTIONDOOR” (see illustration below). The sign shall be aminimumof 6 inches (152 mm) in diameter with black lettering on a yellow background. Additional in-formation may be included.

Additionally one of the following knowing act signs shall be applied:

When a Knowing Act Switch is used to initiate the operation of the door operator, the doorsshall be provided with signs on both sides of the door with the message “ACTIVATE SWITCHTO OPERATE”. The lettering shall be white and the background shall be blue.

When push/pull is used to initiate the operation of the door operator, the doors shall be providedwith the message “PUSH TO OPERATE” on the push side of the door and “PULL TO OPER-ATE” on the pull side of the door. The lettering shall be white and the background shall be blue.

50

±1

2"

50

±1

2"

34

-48

"

50

±1

2"

58

±5

"

CL

Apply to both sides of the door.

When using a wall switch,

apply to both sides of the door.

Apply the push decal to the push

side and the pull decal to the pull

side of the door.

Push plate

PRESS

TO OPEN

1007718-US-3.0Issue 2012-06-2780

20 ANSI / BHMA A156.19 (LOW ENERGY APPLICATION)

Page 81: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0
Page 82: BesamSwingDoorOperator SW200iUS …€¦ · 1 Revision Followingpageshavebeenrevised: Page Revision 2.0 →3.0 11, 52, 64 OPS added to the OPD sensors 4 Issue2012-06-27 1007718-US-3.0

Republic of Ireland:Besam Ltd,unit 39, Navan Enterprise Centre,Trim RoadNavan, Co. MeathTel: +353 46 76747Fax: +353 46 [email protected]

Germany:Besam GmbH,Lagerstraße 45,64807 DieburgTel: +49 6071 2080Fax: +49 6071 208 [email protected]

Hungary:Besam Kft.,Nagytétényi út 112,1222 BudapestTel: +36 1 424 7274Fax: +36 1 226 [email protected]

Australia:Besam Australia Pty Ltd.,235 Huntingdale Road,Oakleigh Victoria,Australia 3166Tel: +61 1300 13 13 10Fax: +61 3 8574 [email protected]

Austria:Besam Austria GmbH,Hütteldorferstraße 216c,1140 WienTel: +43 1 914 55 37 0Fax: +43 1 914 92 [email protected]

Russia:Besam Export AB (Russian office)Box 120, Ovchinnikovskaya nab. 22/24, building 1Moscow 115035 RussiaTel: +7 495 542 97 25Fax: +7 495 542 97 [email protected]

Italy:Besam S.p.A.,Via Monzoro 142,20010 SPietro all’Olmo (MI)Tel: +39 02 936 11 311Fax: +39 02 936 21 [email protected]

Belgium:Besam Belgium NV,Centrum-Zuid 3042,3530 HouthalenTel: +32 11 609 500Fax: +32 11 604 [email protected]

Singapore:Besam (Mfg) Pte Ltd.,No 33 Ubi Ave. 3 #03-52 VertexSingapore 408868Tel: +65 6745 6228Fax: +65 6745 [email protected]

Netherlands:Besam Nederland BV,Postbus 81556710 AD EdeTel: +31 318 69 89 69Fax: +31 318 63 83 [email protected]

Canada:Besam Canada, Inc.,4090 Ridgeway Dr. Unit #16,Mississauga, OntarioL5L 5X5 CanadaTel: 905 608 9242Fax: 905 608 [email protected]

Slovak Republic:Besam, spol. s.r.o.,Kapitulská 15,811 01 BratislavaTel: +421 254 431 045Fax: +421 254 431 [email protected]

Spain:Besam Ibérica S.A.,Sepúlveda, 7A28108 Alcobendas (Madrid)Tel: +34 91 657 48 60Fax: +34 91 661 43 [email protected]

New Zealand:Doorman Besam Ltd.,10 Haultain St.,PD Box 15 784 New Lynn,Auchland 1232Tel: +64 (0)9 815 8392Fax: +64 (0)9 815 [email protected]

China:Besam Automatic Door Systems Trading(Shanghai) Co. Ltd.,Suite 1903,Modern CommunicationCommercial Tower218, Hengfeng Road,Shanghai, PRC 200070Tel: +86 21 5128 8909Fax: +86 21 5128 [email protected]

Sweden:Besam Sverige AB,Box 353261 23 Landskrona, SwedenTel: +46 418 510 00Fax: +46 418 140 [email protected] Export ABBox 669,261 25 LandskronaTel: +46 418 514 00Fax: +46 418 513 [email protected]

Northern Ireland:Tel: +44 (0) 28 71 26 80 11Fax: +44 (0) 28 71 27 11 15info@besam .co.uk

Norway:Besam Norge AS, Brobekkveien 80Postboks 25 Tveita,0617 Oslo, NorwayTel.: +47 69 24 53 00Fax: +47 69 24 53 [email protected]

Czech Republic:Besam spol. s r.o.,Košarova 23,197 00 Praha - KbelyTel: +420 2 8600 1560Fax: +420 286 001 [email protected]

Denmark:Besam A/S,Marielundvej 20,2730 HerlevTel: 44 53 70 80Fax: 44 53 20 [email protected]

United Kingdom:Besam Ltd.,Washington House,Brooklands Close,Sunbury on Thames,Middlesex TW16 7EQTel: +44 1932 765 888Fax: +44 1932 765 [email protected]

Poland:Besam Polska Sp. z.o.o.,ul. J. Olbrachta 94PL-01-102 WarszawaTel: +48 22 331 86 80Fax: +48 22 331 86 [email protected]

Portugal:Besam Portugal,Av. Marechal Gomes da Costa,Fracção AD, 1º Piso, Cabo Ruivo1800-255 LisboaTel: +351 212 969 290Fax: +351 212 974 [email protected]

Finland:Besam OY,Agronominraitti 2,00790 HelsinkiTel: +358 9 7288 5400Fax: +358 9 799 [email protected]

France:Besam S.A.S,10 Rond Point du Général de Gaulle,94864 Bonneuil s/Marne CedexTel: +33 1 43 77 55 66Fax: +33 1 43 39 56 [email protected]

US:Besam US Inc.,1900 Airport Road,Monroe, NC 28110Tel: +1 704 290 5520Fax: +1 704 290 [email protected]

Besam US Inc., 1900 Airport Road, US-Monroe, NC 28110Tel: (704) 290 5520 • Fax: (704) 290 5544Tel: (877) 237 2687 (service) • Tel: (866) 237 2687 (sale)[email protected] • www.besam.com

ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.