automatic control system
DESCRIPTION
Automatic Control System. II. Block diagram model. Modelling dynamical systems. Engineers use models which are based upon mathematical relationships between two variables . We can define the mathematical equations : Measuring the responses of the built process (b lack model ) - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/1.jpg)
Automatic Control SystemII.
Block diagram model
![Page 2: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/2.jpg)
Modelling dynamical systems
Engineers use models which are based upon mathematical relationships between two variables. We can define the mathematical equations:•Measuring the responses of the built process (black model)•Using the basic physical principles (grey model). In order to simplification of mathematical model the small effects are neglected and idealised relationships are assumed.
Developing a new technology or a new construction nowadays it’s very helpful applying computer aided simulation technique.This technique is very cost effective, because one can create a model from the physical principles without building of process.
![Page 3: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/3.jpg)
LTI (Linear Time Invariant) modelThe all physical system are non-linear and their parameters
change during a long time.
The engineers in practice use the superposition’s method.
x(t) y(t)
x(j) y(j)1 1
2 2
1 2 1 2
x (t) y (t)
x (t) y (t)
x (t) x (t) y (t) y (t)
First One defines the input and output signal range.
In this range if an arbitrary input signal energize the block and the superposition is satisfied and the error smaller than a specified error, than the block is linear.
![Page 4: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/4.jpg)
The steady-state characteristics and the dynamic behavior
min
max min
WP1
X(t){dim} X {dim}100 X(t)%
X {dim} X {dim}
X(t) X x(t)
100
0
x(t)
y(t)
t
t
The steady-state characteristic. When the transient’s signals have died a new working point WP2 is defined in the steady-state characteristic.
The dynamic behavior is describe by differential equation or transfer function in frequency domain.
WP2
WP1
100
0
min
max min
WP1
Y(t){dim} Y {dim}100 Y(t)%
Y {dim} Y {dim}
Y(t) Y y(t)
![Page 5: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/5.jpg)
Transfer function in frequency domain
Amplitude gain:
Phase shift:
( )( )( ) ( )
( ) jout
in
y jG j A e
x j
( ) 20lg ( )a dB A
Im ( )( )
Re ( )
G jarctg
G j
( ) ( )A G j
![Page 6: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/6.jpg)
The graphical representation of transfer function
• The M-α curves: The amplitude gain M(ω) in the frequency domain. In the previous page M(ω) was signed, like A(ω) The phase shift α(ω) in the frequency domain. In the previous page α(ω) was signed, like φ(ω)!
• A Nyquist diagram: The transfer function G(jω) is shown on the complex plane.
• A Bode diagram: Based on the M-α curves. The frequency is in logaritmic scale and instead of A(ω) amplitude gain is:
• A Nichols diagram: The horizontal axis is φ(ω) phase shift and the vertical axis is The a(ω) dB.
( ) 20lg ( )a dB A
![Page 7: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/7.jpg)
The basic transfer functionIn the time domain is the
differential equitation
y(t) Ax(t)
y(s) 1
x(s) 1 sT
dy(t)
T y(t) x(t)dt
y(s)A
x(s)
22
2
d y(t) dy(t)T 2 T y(t) x(t)
dt dt 2 2
y(s) 1
x(s) 1 s2 T s T
i
dy(t)T x(t)
dt
i
y(s) 1
x(s) sT
d
dx(t)y(t) T
dt d
y(s)sT
x(s)
y(t) 1(t )x(t ) sy(s)e
x(s)
In the frequency domain is the transfer function
![Page 8: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/8.jpg)
Block representationActuating path of signals and variables
One input and one output block represents the context between the the output and input signals or variables in time or frequency domain
Summing junction
Take-off point (The same signal actuate both path)
G1 G2 G1G2
G1
G2
G1+G2
G1
G2
21
1
1 GG
G
![Page 9: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/9.jpg)
P proportional
Step response Bode diagram
t
![Page 10: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/10.jpg)
I Integral
Step response Bode diagram
![Page 11: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/11.jpg)
D differential
Step response Bode diagram
The step response is an Dirac delta, which isn’t shown
![Page 12: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/12.jpg)
PT1 first order system
Step response Bode diagram
![Page 13: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/13.jpg)
PT2 second order system
Step response Bode diagram
![Page 14: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/14.jpg)
PH delay
Step response Bode diagram
![Page 15: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/15.jpg)
IT1 integral and first order in cascade
Step response Bode diagram
![Page 16: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/16.jpg)
DT1 differential and first order in cascade
Step response Bode diagram
![Page 17: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/17.jpg)
PI proportional and integral in parallel
Step response Bode diagram
![Page 18: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/18.jpg)
PDT1
Step response Bode diagram
![Page 19: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/19.jpg)
plantcontroller
Terms of feedback control
reference input element
reference signal
comparing elementor error detector
error signal
compensator or control task
action signal
feedback signal
actuator
transmitter
manipulated variable
disturbance variable
controlled variable
block model of the plant
![Page 20: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/20.jpg)
Block diagram manipulation
G1
G1 G2 G1G2
G2
G1+G2
G1
G2
21
1
1 GG
G
G1
G1
G1
G1 G1
1
1
G
G1
G1
G1
G1 G1
1
1
G
![Page 21: Automatic Control System](https://reader033.vdocuments.us/reader033/viewer/2022061614/56812c25550346895d90906d/html5/thumbnails/21.jpg)
Block diagram reduction example
G5
G2
G7
G6
G1 G3
G4
)(sx )(sy
765317641532
7417531
1)(
)()(
GGGGGGGGGGGG
GGGGGGG
sx
sysG