aruf series - climaproyectos s.a. de c.v
TRANSCRIPT
SS-DARUF www.daikincomfort.com 5/16Supersedes 2/15
ARUF Series
Product Features• Check flowrator for cooling
and heat pump applications• Direct drive, multi-speed PSC blower motor• All-aluminum evaporator coil• Coil mounting track for quick repositioning• Cabinet air leakage less than 2.0% at
1.0 inch H₂O when tested in accordance with ASHRAE standard 193
• Cabinet air leakage less than 1.4% at 0.5 inch H₂O when tested in accordance with ASHRAE standard 193
• 3 kW – 25 kW electric heater kits• Horizontal or vertical configuration capabilities• AHRI certified; ETL listed
• Rigid SmartFrame™ cabinet• 21" depth for easier attic access• DecaBDE-free thermoplastic drain
pan with secondary drain connections• Screw-less sides and back helps
to reduce condensation when installed in humid locations
• Foil-faced insulation covers the internal casing to reduce cabinet condensation
• Galvanized, leather grain-embossed finish• Glue-less cabinet insulation retention • Tool-less filter access
* Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec.
■ ContentsNomenclature ....................................... 2Product Specifications .......................... 3Heater Kit Nomenclature ...................... 3Dimensions ........................................... 4Airflow Data .......................................... 5Heat Kit Data ......................................... 6Wiring Diagrams ................................... 9Accessories ......................................... 11
Multi-Position Multi-Speed Air Handler
with PSC Motor 1½ to 5 Tons
2 www.daikincomfort.com SS-DARUF SS-DARUF www.daikincomfort.com 3
Nomenclature
B 1 7 8
Brand Engineering *A Single-‐piece Major/ Minor Revisions
Air Handler * Not used for inventory management
Unit Application Refrigerant ChargeC Ceiling Mount PSC Motor 4 = R-‐410AD Downflow PSC MotorE Multi-‐Position Variable-‐Speed Motor ElectricalR Multi-‐Position PSC Motor 1 208/240 V, 1 Phase, 60 HzS Multi-‐Position EEM MotorW Wall Mount PSC Motor Cabinet Width
B 17½"Cabinet Finish C 21"U Unpainted D 24½"P PaintedN Uncased Nominal Capacity Range @ 13 SEER
18 1½ Tons 42 3½ TonsExpansion Device 24 2 Tons 48 4 TonsF Flowrater 30 2½ Tons 60 5 TonsT Expansion Valve 36 3 Tons
AA11,12
U3
F4 10
4R2 5,6
181A
HKS X 03 X A AA
1 2 3 4 5 6,7
Unit Type RevisionsHKS Heat Kit for Engineering Revisions
Air HandlersPhase
Circuit Breaker A Single Phase 208 V E Three Phase 240 VX No circuit breaker B Single Phase 240 V F Three Phase 208/240 VC Circuit Breaker C Single Phase 208/240 V G Three Phase 460 V
D Three Phase 208 VHeating Capacity @ 240 Volts03 3.0 kW 15 14.4 kW Cabinet Size (MAX)05 4.5 kW 19 19.2 kW wth 150F limit C C Cabinet06 6.0 kW 20 19.2 kW with 170F limit D D Cabinet08 8.0 kW 25 25.0 kW X All Cabinet Sizes10 9.6 kW
2 www.daikincomfort.com SS-DARUF SS-DARUF www.daikincomfort.com 3
ARUF25B14*
ARUF29B14*
ARUF31B14*
ARUF37C14*
ARUF43C14*
ARUF49C14*
ARUF37D14*
ARUF43D14*
ARUF47D14*
ARUF49D14*
ARUF61D14*
Nominal Ratings
Cooling (Btu/h) 24,000 25,000 30,000 36,000 42,000 48,000 36,000 42,000 43,000 48,000 60,000
Piston Size 0.051 0.057 0.065 0.072 0.076 0.080 0.072 0.076 0.076 0.080 0.080
Blower
Diameter 9½" 9½" 9½" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 1115/16"
Width 6" 6" 6" 8" 8" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝"
Coil Connections
Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Suction ¾" ¾" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞"
Coil Drain Connect (FPT) ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾" ¾"
Electrical Data
Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Min Circuit Ampacity 2.4/2.4 2.4/2.4 2.4/2.4 4/4 4/4 4/4 4/4 4/4 4/4 4/4 6/6
Max. Overcurrent Device (Amps) 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15 15/15
Minimum VAC 197 197 197 197 197 197 197 197 197 197 197
Maximum VAC 253 253 253 253 253 253 253 253 253 253 253
Blower Motor
Full Load Amps (FLA) 1.9 1.9 1.9 3.0 3.0 3.1 3.0 3.5 3.5 3.5 4.6
Horsepower (HP) ⅓ ⅓ ⅓ ⅓ ⅓ ½ ⅓ ½ ½ ½ ¾
Ship Weight (Lbs.) 100 100 110 130 130 135 140 145 150 145 155
Note: For a properly matched system and piston sizing information, refer to Amana piston kit chart of the corresponding Amana® outdoor unit. Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate and/or Heat Kit Data for specification with approved accessory heaters installed.
Product Specifications
4 www.daikincomfort.com SS-DARUF SS-DARUF www.daikincomfort.com 5
Dimensions
G
H
E D
1 3/4" (4.45 cm)
2 11/16" (6.83 cm)
C
B 5/8" (1.59 cm) 5/8" (1.59 cm)
A
1/2" (1.27 cm)
11 5/16" (28.73 cm)
" (55.88 cm)21
9 1/4" (23.50 cm)
1 3/8" (3.49 cm) 3 1/8" (7.94 cm)
5 1/8" (13.02 cm)
7 1/2" (19.05 cm)
1 3/4" (4.45 cm)
7 3/16" (18.26 cm)
K
J 2 1/8" (5.40 cm)
4 5/16" (4.31 cm)
6 1/8" (15.56 cm)
1 13/16" (4.60 cm) FINLET
(FRONT VIEW)
1 13/16" (4.60 cm)" (2.54 cm)1 9/16 (1.43 cm) 19.5" (49.53 cm)
INLET(RIGHT SIDE VIEW)
10 3/16" (25.88 cm)
1 5/8" (4.13 cm)
1 5/16" (3.33 cm)
4 1/2" (11.43 cm)
1 5/8" (4.13 cm) 3 3/4" (9.53 cm)
2 15/16" (7.46 cm)
3 1/16" (7.78 cm)
SEE HORIZONTAL DRAIN PORT DETAIL
SEE VERTICAL DRAIN PORT DETAIL
SUCTION TUBE LIQUID LINEINLET TUBE
HORIZONTAL DRAIN PORT DETAIL
VERTICAL DRAIN PORT DETAIL
Model A" B" C" D" E" F" G" H"
ARUF25B14* 45 16⅜ 17½ 15¼ 12 14⅛ 9⅛ 11⅞
ARUF29B14* 45 16⅜ 17½ 15¼ 12 14⅛ 9⅛ 12¾
ARUF31B14* 537/16 16⅜ 17½ 2311/16 20½ 14⅛ 9⅛ 7⅝
ARUF37C14* 537/16 19⅞ 21 2113/16 18⅝ 1711/16 1013/16 613/16
ARUF43C14* 537/16 19⅞ 21 2113/16 18⅝ 1711/16 1013/16 613/16
ARUF49C14* 537/16 19⅞ 21 2113/16 18⅝ 1711/16 1013/16 613/16
ARUF37D14* 537/16 235/16 24½ 21½ 185/16 213/16 12⅝ 6⅞
ARUF43D14* 537/16 235/16 24½ 21½ 185/16 213/16 12⅝ 6⅞
ARUF47D14* 58 235/16 24½ 26⅛ 22⅞ 213/16 12⅝ 252/16
ARUF49D14* 537/16 235/16 24½ 21½ 185/16 213/16 12⅝ 6⅞
ARUF61D14* 58 235/16 24½ 26⅛ 22⅞ 213/16 12⅝ 252/16
4 www.daikincomfort.com SS-DARUF SS-DARUF www.daikincomfort.com 5
Airflow Data
Model MotorSpeed
Static Pressure (in w.c) Airflow (CFM)
0.1 0.2 0.3 0.4 0.5 0.6 0.7
ARUF25B14
Low 650 620 595 540 490 420 275
Med 885 865 825 815 750 690 560
High 1255 1225 1130 1090 965 925 800
ARUF29B14
Low 650 620 595 540 490 420 275
Med 885 865 825 815 750 690 560
High 1255 1225 1130 1090 965 925 800
ARUF31B14
Low 660 625 595 560 500 430 330
Med 930 905 865 820 765 700 590
High 1235 1185 1130 1060 990 910 825
ARUF37C14
Low 1120 1085 1040 1000 940 875 800
Med 1425 1385 1345 1285 1220 1145 1060
High 1625 1575 1520 1460 1375 1295 1200
ARUF43C14
Low 1120 1085 1040 1000 940 875 800
Med 1425 1385 1345 1285 1220 1145 1060
High 1625 1575 1520 1460 1375 1295 1200
ARUF49C14
Low 1295 1255 1225 1175 1120 1055 970
Med 1535 1485 1420 1370 1295 1215 1130
High 1755 1680 1590 1515 1425 1340 1250
ARUF37D14
Low 1155 1115 1070 1015 955 895 840
Med 1505 1470 1430 1375 1300 1210 1105
High 1785 1735 1680 1625 1555 1440 1330
ARUF43D14
Low 1410 1360 1290 1210 1120 1010 920
Med 1610 1540 1470 1390 1300 1190 1060
High 1900 1830 1740 1645 1540 1420 1280
ARUF47D14
Low 1420 1370 1310 1240 1125 1045 960
Med 1625 1585 1515 1435 1350 1235 1095
High 1930 1890 1820 1735 1635 1505 1355
ARUF49D14
Low 1410 1360 1290 1210 1120 1010 920
Med 1610 1540 1470 1390 1300 1190 1060
High 1900 1830 1740 1645 1540 1420 1280
ARUF61D14
Low 1530 1500 1460 1405 1350 1280 1155
Med 1950 1885 1830 1785 1745 1670 1595
High 2235 2170 2100 2030 1965 1915 1825
Notes• Airflow data indicated is at 230V without air filter in place. • The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate.
The shaded area indicates ranges in excess of maximum design external static pressure.• Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations
6 www.daikincomfort.com SS-DARUF SS-DARUF www.daikincomfort.com 7
Heat Kit Data
Model & Heater KitCircuit 1 Circuit 2 Single-Point Kit
Heater MCA¹ MOP² Heater Amps MCA¹ MOP² MCA¹ MOP²
ARUF25B14AA 0/0 2.4/2.4 15/15 --- --- --- --- ---
HKS*03XC* 10.8/12.5 16/18 20/20 --- --- --- --- ---
HKS*05XC* 17.3/20 24/27 25/30 --- --- --- --- ---
HKS*06XC* 21.7/25 29/34 30/35 --- --- --- --- ---
HKS*08XC* 28.9/33.3 38/44 40/45 --- --- --- --- ---
HKS*10XC* 34.7/40 46/52 50/60 --- --- --- --- ---
ARUF29B14AA 0/0 2.4/2.4 15/15 --- --- --- --- ---
HKS*03XC* 10.8/12.5 16/18 20/20 --- --- --- --- ---
HKS*05XC* 17.3/20 24/27 25/30 --- --- --- --- ---
HKS*06XC* 21.7/25 29/34 30/35 --- --- --- --- ---
HKS*08XC* 28.9/33.3 38/44 40/45 --- --- --- --- ---
HKS*10XC* 34.7/40 46/52 50/60 --- --- --- --- ---
ARUF31B14AA 0/0 2.4/2.4 15/15 --- --- --- --- ---
HKS*03XC* 10.8/12.5 16/18 20/20 --- --- --- --- ---
HKS*05XC* 17.3/20 24/27 25/30 --- --- --- --- ---
HKS*06XC* 21.7/25 29/34 30/35 --- --- --- --- ---
HKS*08XC* 28.9/33.3 38/44 40/45 --- --- --- --- ---
HKS*10XC* 34.7/40 46/52 50/60 --- --- --- --- ---
HKSC15*#* 34.7/40 46/53 50/60 17.3/20 22/25 25/25 67/77 70/80
ARUF37C14AA 0/0 4/4 15/15 --- --- --- --- ---
HKS*03XC* 10.8/12.5 17/19 20/20 --- --- --- --- ---
HKS*05XC* 17.3/20 25/29 30/30 --- --- --- --- ---
HKS*06XC* 21.7/25 31/35 35/35 --- --- --- --- ---
HKS*08XC* 28.9/33.3 40/45 40/50 --- --- --- --- ---
HKS*10XC* 34.7/40 47/54 50/60 --- --- --- --- ---
HKSC15*#* 34.7/40 47/54 50/60 17.3/20 22/25 25/25 69/79 70/80
HKSC19C#* 34.7/40 47/54 50/60 34.7/40 43/50 45/50 90/104 100/110
HKS*15XF* 0/0 4/4 15/15 30/34.6 38/43 40/45 --- ---
HKS*20XF* 0/0 4/4 15/15 38/43 47/54 50/60 --- ---
ARUF43C14AA 0/0 4/4 15/15 --- --- --- --- ---
HKS*03XC* 10.8/12.5 17/19 20/20 --- --- --- --- ---
HKS*05XC* 17.3/20 25/29 30/30 --- --- --- --- ---
HKS*06XC* 21.7/25 31/35 35/35 --- --- --- --- ---
HKS*08XC* 28.9/33.3 40/45 40/50 --- --- --- --- ---
HKS*10XC* 34.7/40 47/54 50/60 --- --- --- --- ---
HKSC15*#* 34.7/40 47/54 50/60 17.3/20 22/25 25/25 69/79 70/80
HKSC19C#* 34.7/40 47/54 50/60 34.7/40 43/50 45/50 90/104 100/110
HKS*15XF* 0/0 4/4 15/15 30/34.6 38/43 40/45 --- ---
HKS*20XF* 0/0 4/4 15/15 38/43 47/54 50/60 --- ---
¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25 ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps* Revision level that may or may not be designated C = Circuit Breaker Option CA indicates 208V and CB indicates 240V--- indicates Not Required
6 www.daikincomfort.com SS-DARUF SS-DARUF www.daikincomfort.com 7
Heat Kit Data (cont.)
Model & Heater KitCircuit 1 Circuit 2 Single-Point Kit
Heater MCA¹ MOP² Heater Amps MCA¹ MOP² MCA¹ MOP²
ARUF49C14AA 0/0 4/4 15/15 --- --- --- --- ---
HKS*03XC* 10.8/12.5 17/20 20/20 --- --- --- --- ---
HKS*05XC* 17.3/20 26/29 30/30 --- --- --- --- ---
HKS*06XC* 21.7/25 31/35 35/40 --- --- --- --- ---
HKS*08XC* 28.9/33.3 40/46 45/50 --- --- --- --- ---
HKS*10XC* 34.7/40 47/54 50/60 --- --- --- --- ---
HKSC15*#* 34.7/40 47/54 50/60 17.3/20 22/25 25/25 69/79 70/80
HKSC19C#* 34.7/40 47/54 50/60 34.7/40 43/50 45/50 91/104 100/110
HKS*15XF* 0/0 4/4 15/15 30/34.6 38/43 40/45 --- ---
HKS*20XF* 0/0 4/4 15/15 38/43 47/54 50/60 --- ---
ARUF37D14AA 0/0 4/4 15/15 --- --- --- --- ---
HKS*03XC* 10.8/12.5 17/19 20/20 --- --- --- --- ---
HKS*05XC* 17.3/20 25/29 30/30 --- --- --- --- ---
HKS*06XC* 21.7/25 31/35 35/35 --- --- --- --- ---
HKS*08XC* 28.9/33.3 40/45.4 40/50 --- --- --- --- ---
HKS*10XC* 34.7/40 47/54 50/60 --- --- --- --- ---
HKSC15*#* 34.7/40 47/54 50/60 17.3/20 22/25 25/25 69/79 70/80
HKSC20D#* 34.7/40 47/54 50/60 34.7/40 44/50 45/50 90/104 100/110
HKS*15XF* 0/0 4/4 15/15 30/34.6 38/43 40/45 --- ---
HKS*20XF* 0/0 4/4 15/15 38/43 47/54 50/60 --- ---
ARUF43D14AA 0/0 4/4 15/15 --- --- --- --- ---
HKS*03XC* 10.8/12.5 18/20 20/20 --- --- --- --- ---
HKS*05XC* 17.3/20 26/29 30/30 --- --- --- --- ---
HKS*06XC* 21.7/25 31/36 35/40 --- --- --- --- ---
HKS*08XC* 28.9/33.3 40/46 45/50 --- --- --- --- ---
HKS*10XC* 34.7/40 48/54 50/60 --- --- --- --- ---
HKSC15*#* 34.7/40 48/54 50/60 17.3/20 22/25 25/25 69/79 70/80
HKSC20D#* 34.7/40 48/54 50/60 34.7/40 43/50 45/50 91/104 100/110
HKS*15XF* 0/0 4/4 15/15 30/34.6 38/43 40/45 --- ---
HKS*20XF* 0/0 4/4 15/15 38/43 47/54 50/60 --- ---
ARUF49D14AA 0/0 4/4 15/15 --- --- --- --- ---
HKS*03XC* 10.8/12.5 18/20 20/20 --- --- --- --- ---
HKS*05XC* 17.3/20 26/29 30/30 --- --- --- --- ---
HKS*06XC* 21.7/25 31/36 35/40 --- --- --- --- ---
HKS*08XC* 28.9/33.3 40/46 45/50 --- --- --- --- ---
HKS*10XC* 34.7/40 48/54 50/60 --- --- --- --- ---
HKSC15*#* 34.7/40 48/54 50/60 17.3/20 22/25 25/25 69/79 70/80
HKSC20D#* 34.7/40 48/54 50/60 34.7/40 43/50 45/50 91/104 100/110
HKS*15XF* 0/0 4/4 15/15 30/34.6 38/43 40/45 --- ---
HKS*20XF* 0/0 4/4 15/15 38/43 47/54 50/60 --- ---
¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25 ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps* Revision level that may or may not be designated C = Circuit Breaker Option CA indicates 208V and CB indicates 240V--- indicates Not Required
8 www.daikincomfort.com SS-DARUF SS-DARUF www.daikincomfort.com 9
Model & Heater KitCircuit 1 Circuit 2 Single-Point Kit
Heater MCA¹ MOP² Heater Amps MCA¹ MOP² MCA¹ MOP²
ARUF47D14AA 0/0 4/4 15/15 --- --- --- --- ---
HKS*03XC* 10.8/12.5 18/20 20/20 --- --- --- --- ---
HKS*05XC* 17.3/20 26/29 30/30 --- --- --- --- ---
HKS*06XC* 21.7/25 31/36 35/40 --- --- --- --- ---
HKS*08XC* 28.9/33.3 40/46 45/50 --- --- --- --- ---
HKS*10XC* 34.7/40 48/54 50/60 --- --- --- --- ---
HKSC15*#* 34.7/40 48/54 50/60 17.3/20 22/25 25/25 69/79 70/80
HKSC20D#* 34.7/40 48/54 50/60 34.7/40 44/50 45/50 91/104 100/110
HKS*15XF* 0/0 4/4 15/15 30/34.6 38/43 40/45 --- ---
HKS*20XF* 0/0 4/4 15/15 38/43 47/54 50/60 --- ---
ARUF61D14AA 0/0 6/6 15/15 --- --- --- --- ---
HKS*03XC* 10.8/12.5 19/21 20/25 --- --- --- --- ---
HKS*05XC* 17.3/20 27/31 30/35 --- --- --- --- ---
HKS*06XC* 21.7/25 33/37 35/40 --- --- --- --- ---
HKS*08XC* 28.9/33.3 42/47 45/50 --- --- --- --- ---
HKS*10XC* 34.7/40 49/56 50/60 --- --- --- --- ---
HKSC15*#* 34.7/40 49/56 50/60 17.3/20 22/25 25/25 71/81 80/90
HKSC20D#* 34.7/40 49/56 50/60 34.7/40 43/50 45/50 92/106 100/110
HKS*15XF* 0/0 6/6 15/15 30/34.6 38/43 40/45 --- ---
HKS*20XF* 0/0 6/6 15/15 38/43 47/54 50/60 --- ---
HKSC25DC* 52/60 71/81 80/90 35/40 43/50 45/50 114/131 125/150
¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25 ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps* Revision level that may or may not be designated C = Circuit Breaker Option CA indicates 208V and CB indicates 240V--- indicates Not Required
Heating kW Correction Factor
Supply Voltage 240 230 220 210 208
Correction Factor 1.00 0.92 0.84 0.77 0.75
Multiply the 240-volt heating capacity by correction factors.
Heat Kit Data (cont.)
8 www.daikincomfort.com SS-DARUF SS-DARUF www.daikincomfort.com 9
USE
CO
PPER
WIR
E
SPEE
DUP
CO
PPER
PO
WER
SUP
PLY
(SEE
RAT
ING
PLA
TE)
EQU
IPM
ENT
GR
OUN
D
BLBL
SEE
NOTE
3
BK
M1
BRBRR
C
EM
RD
BL
BK
RD
PU
WH EB
TDR
SR
BL
G
RD
XFM
R-R
XFM
R-C
CR
RD
GR
SEE
NO
TES
2 &
6
BLR
DG
RW
HBR
5
NO
CO
M
NC
K1K1
PU
PU
RD
RD
C
BK
BR
PLF
BK1
RD
PU
23
240
24V
4
12
3
TR
RD
SEE
NO
TE 4
BLBR
45
WH6
78
9PL
M
GR
ND
1BK
23
RDL2
L1
45
67
89
0140
A002
42-A
PLM
PLF
TRFACT
OR
Y W
IRIN
G
FIEL
D W
IRIN
G
NOTE
S:
TIM
E DE
LAY
REL
AY
STR
AIN
REL
IEF
EVAP
ORA
TOR
MO
TOR
ELEC
TRO
NIC
BLO
WER
RUN
CAP
ACIT
OR
SREM
EBTD
R
RCBK RD BLYL
BLU
E
BLAC
KR
EDYE
LLO
W
CO
MPO
NENT
CO
DE
BROW
NPU
RPL
EG
REE
NPU BRG
R
FEM
ALE
PLUG
CO
NNEC
TOR
MAL
E PL
UG C
ON
NECT
OR
TRAN
SFO
RM
ER
H
IGH
VO
LTAG
E
LOW
VO
LTAG
E
H
IGH
VO
LTAG
E
LOW
VO
LTAG
E
PLF
32
CO
LOR
CO
DE
RD
TR
WH6
BR5PL
M4
424
V5
SEE
NOTE
11
23
RC
HI
EM
GR
WIR
ING
CO
DE
BL
EBTD
R
LOC
OM
NC
M1
EBTD
R
NO
208/
240
VOLT
S
11PL
F
PLM
L1
PLM
2L2
(M2)
PU RC
(M1)
BKBLM
EDIU
M
3 SP
EED
BRHIG
H
EM
(CO
M)
RD
LOW
IF R
EPLA
CEM
ENT
OF
THE
OR
IGIN
AL W
IRES
SUPP
LIED
WIT
H TH
IS A
SSEM
BLY
IS N
ECES
SAR
YUS
E W
IRE
THAT
CO
NFO
RM
S TO
TH
ENA
TIO
NAL
ELE
CTR
IC C
ODE
.
M2
PU(TR
1)
M2
RG
CEB
TDR
SEE
NOTE
1
FLFU
SE L
INK
TLTH
ERM
AL L
IMIT
SEE
NOTE
5
RR
ELAY
TER
MIN
AL B
LOC
K SH
OW
NFO
R 5
0HZ
MO
DEL
S O
NLY
THR
EE S
PEED
MO
TOR
WIR
ING
(SEL
ECT
MO
DEL
S O
NLY
)SE
E N
OTE
3
WHI
TEW
HUS
E M
IN. 7
5°C
FIE
LD W
IRE
1. R
ED W
IRES
TO
BE
ON
TR
ANSF
OR
ME
R T
ERM
INAL
"3" F
OR
240
VO
LTS
A
ND
ON
TER
MIN
AL "2
" FO
R 2
08 V
OLT
S.2.
SEE
CO
MP
OSI
TE W
IRIN
G D
IAG
RA
MS
IN IN
STAL
LATI
ON
INST
RU
CTI
ON
S
FO
R P
RO
PER
LO
W V
OLT
AGE
WIR
ING
CO
NN
ECTI
ON
S.3.
CO
NFI
RM S
PEED
TAP
SEL
ECTE
D IS
APP
RO
PRIA
TE F
OR
APP
LIC
ATIO
N.
IF
SPE
ED T
AP N
EED
S TO
BE
CHA
NG
ED, C
ON
NEC
T AP
PRO
PRIA
TE
MO
TOR
WIR
E (R
ED F
OR
LO
W, B
LUE
FOR
MED
IUM
, AN
D B
LACK
FO
R
HIG
H S
PEED
) ON
"CO
M" C
ON
NEC
TIO
N O
F TH
E EB
TDR
.
INAC
TIVE
MO
TOR
WIR
ES M
US
T BE
CO
NN
ECTE
D T
O "M
1 O
R M
2"
O
N E
BTD
R.
4. B
RO
WN
AN
D W
HIT
E W
IRES
AR
E U
SED
WIT
H H
EAT
KITS
ON
LY.
5. E
BTD
R H
AS A
7 S
ECO
ND
ON
DEL
AY W
HEN
"G" I
S EN
ERG
IZED
A
ND
A 6
5 SE
CON
D O
FF D
ELAY
WH
EN "G
" IS
DE-
ENER
GIZ
ED.
6. L
OW
VO
LTAG
E FI
ELD
WIR
ING
TO
BE
N.E
.C C
LASS
2 W
IRES
.
GRN
DG
RO
UND
SEE
NOTE
S 2
& 6
Wiring Diagram – Air Handler
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.
⚡
10 www.daikincomfort.com SS-DARUF SS-DARUF www.daikincomfort.com 11
Wiri
ng is
sub
ject
to c
hang
e. A
lway
s re
fer
to t
he w
iring
dia
gram
on
the
unit
for t
he m
ost u
p-to
-dat
e w
iring
.⚠
War
ning
High
Vol
tage
: D
isco
nnec
t al
l po
wer
bef
ore
serv
icin
g or
ins
talli
ng t
his
unit.
Mul
tiple
pow
er
sour
ces
may
be
pres
ent.
Failu
re to
do
so m
ay c
ause
pro
pert
y da
mag
e, p
erso
nal i
njur
y, o
r de
ath.
⚡
Wiring Diagram – Three-Phase Heater Kit
RC
BR BREM
35
214
RD
TR
WH
BR
BK
L2
L1
RD
RD
BL
BK
PU
BLPU
REL
AY/S
EQU
ENC
ER
THER
MAL
LIM
ITTR
ANSF
OR
MER
RU
N C
APAC
ITO
R
ELEC
. BLO
WER
TIM
E D
ELAY
REL
AYEV
APO
RA
TOR
MO
TOR
HEA
T EL
EMEN
TH
TR
EBTD
REM R
S
TL TRRCCO
MPO
NEN
T C
OD
E
24 V
OLT
TR
RC
EM
EBTD
R
EBTD
R
CO
MNO
NC
208/
240
VOLT
S
0140
M00
273-
A
WH
BK
GND L3
T3
CC
L2L1
BL
T2T1
R
BL
RD
BR
M3 M
4PU
M2
PUW
H
M1
WH
WH
RS
BL
WH
PU
BL
RD
1 2 3 5 7 8 964
WH
PC
EBTD
R
TER
MIN
AL B
LOC
KC
ON
TAC
TOR
9-PI
N C
ON
NEC
TOR
PCCC
TB
M2
RS
M1
M3
M4
L1L2
LOW
HIG
H
CC
HEA
TER
CO
NTR
OL
AR P
OW
ER S
UPP
LY
1 2 3 4 5 6 7 8 9PC
(CIR
CU
IT 1
)
NC
SPEE
DU
P
GR
CRD
XFM
R-R
XFM
R-C
M1
CO
MK1
NO
K1
L1
RD
GR PK
BL
PU
SR
STR
AIN
REL
IEF
M1
YL
YEL
LOW
BK
BLA
CK
BL
BLU
EBR
BR
OW
NG
R
GR
EEN
OR
O
RAN
GE
PK
PIN
KPU
PU
RP
LER
D
RED
WH
W
HIT
E
CO
LOR
CO
DE
(CIR
CU
IT 2
)H
KR P
OW
ER S
UPP
LYL1
L2L3
FLSRFU
SE L
INK
W2
W1
WBR
GR
BLPK
GR
CR
D
T1T2
T3
12
3
45
FLH
TR3
TL
FLH
TR2
TL
FLH
TR1
TL
TLFL
HTR
3TL
FLH
TR2
TLFL
HTR
1
CB
CIR
CU
IT B
REA
KER
L1L2
L3
BKBK
BK
BK BK
BK
BKBK
BK
BKBK
BK
BKBK
BK
BK
BK
BK
BK
WIR
ING
CO
DE
HIG
H V
OLT
AGE
LOW
VO
LTAG
E
BK
NO
TE: W
HEN
INST
ALLI
NG
HEA
TER
KIT
, EN
SUR
E SP
EED
TAP
MU
ST E
XCEE
D O
R E
QU
AL T
HE
MIN
IMU
M B
LOW
ER S
PEED
(MBS
) SPE
CIF
IED
FO
R T
HE
AIR
HAN
DLE
R/H
EATE
R K
IT C
OM
BIN
ATIO
N O
N T
HIS
UN
IT'S
SER
IAL
PLAT
E.AF
TER
INST
ALLI
NG
OPT
ION
AL H
EAT
KIT,
MAR
K AN
"X" I
N T
HE
PR
OVI
DED
BEL
OW
.N
O M
ARK
IND
ICAT
ES N
O H
EAT
KIT
INST
ALLE
D.
NO
TE:-
THIS
LAB
EL M
UST
BE
ATTA
CH
ED O
N T
HE
AIR
HAN
DLE
R IN
A P
RO
MIN
ENT
LOC
ATIO
N
BKRD
TB
L1L2
CIR
CU
IT 1
1 PH
208
-240
V
CIR
CU
IT 2
3 PH
. 208
-240
V
10 www.daikincomfort.com SS-DARUF SS-DARUF www.daikincomfort.com 11
Accessories
Expansion Valve Kits for Air Conditioning and Heat Pump Applications
Kit Number Description Application Refrigerant Tonnage:
Outdoor Unit
TX2N4A Non-bleed Valve AC or HP R-410A 1½ - 2 Ton
TX3N4 Non-bleed Valve AC or HP R-410A 2½ - 3 Ton
TX5N4 Non-bleed Valve AC or HP R-410A 3½ - 5 Ton
Downflow Insulation Kit
DFK-B DFK-C DFK-D
ARUF25B14** ARUF37C14** ARUF37D14**
ARUF29B14** ARUF43C14** ARUF43D14**
ARUF31B14** ARUF49C14** ARUF47D14**
ARUF49D14**
ARUF61D14**
Filters
Chassis Part # Size
B ALFH16201E 16.0” x 20.0”
C ALFH1912201E 19.5” x 20.0”
D ALFH20231E 23.0” x 20.0”
12 www.daikincomfort.com SS-DARUF SS-DARUF www.daikincomfort.com PB
Our continuing commitment to quality products may mean a change in specifications without notice. ©2016 daikin manufacturing company, l.p. • Houston, Texas • Printed in the USA.
Notes