appendix c architectural drawings

4
Date 1/03/16 Issue 1.0 160301_MSCP_Response to Submissions Multi Storey Car Park Page 26 of 39 Appendix C Architectural drawings Prepared by HDR Rice Daubney Architects January 2016

Upload: others

Post on 14-Apr-2022

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Appendix C Architectural drawings

Date 1/03/16 Issue 1.0 160301_MSCP_Response to Submissions

Multi Storey Car Park Page 26 of 39

Appendix C Architectural drawings

Prepared by HDR Rice Daubney Architects

January 2016

Page 2: Appendix C Architectural drawings

DENTAL ADMIN

WH6STAFF CAR PARK 6

1-4LAVENDER COTTAGE

DENTALADMIN

ONGRADECARPARKZONE B

ONGRADECARPARKZONE A

LANDSCAPEDAREA

CARPARK WH6

ORAL HEALTH

DARCY ROAD MULTISTOREY CARPARK

ICPMR

INSTITUTE ROAD

DA

RC

Y R

OA

D

LAVENDER COTTAGE

NEW ACCESS ROAD TOMULTI DECK CAR PARKAND EXISTING CAR PARKWH6

CONNECTING PAVED WALKWAY

ZEBRACROSSINGS AS

PER CIVIL AND

LANDSCAPE

REQUIREMENTS

ELE

C

PYLON SIGN PARKINGINDICATOR. REFER TOWAY FINDING ANDSIGNAGE

AT-GRADE CARPARK

APPROX RL 19.000

DG-12100

1

THE WORKS WITHIN THE GREYHATCHED AREA NORTH OFINSTITUTE ROAD WILL BEUNDERTAKEN BY THE EARLYAND ENABLING WORKSCONTRACTOR. THIS WORK DOESNOT FORM PART OF THE MSCPPROJECT. THE RESPECTIVECONTRACTORS WILL NEED TOMANAGE AND COORDINATEWORKS ALONG THIS INTERFACEREFER TO LANDSCAPE AND CIVIL

DOCUMENTS FOR MOUND, PATHAND ROADWAY DESIGN

SP01

PLANNORTH TRUE

NORTH

SCALE:

DRAWING TITLE:

DRAWING NUMBER:

CHECKED:

THIS DOCUMENT IS THE COPYRIGHT OF THE HDR|RD GROUP (NSW) Pty.LtdALL THE INFORMATION ILLUSTRATED ON THIS DOCUMENT IS TO BE CHECKED AND VERIFIED ON SITE.IN THE EVENT OF DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK.DO NOT SCALE DRAWINGS ELECTRONICALLY OR MANUALLY

PROJECT NUMBER: ISSUE:

CLIENT:

Level 6, 77 Pacific HighwayNorth Sydney NSW 2060

P: (02) 9978 5427

www.hinfra.health.nsw.gov.au

F: (02) 8904 1377

PROJECT MANAGER:

Darling Park201 Sussex StreetSydney NSW 2000

P: (02) 8266 2750

www.pwc.com.au

F: (02) 8286 2750

NOT FOR CONSTRUCTION

DOHRS NUMBER:

5335

LEAD ARCHITECT:

Lvl 1, 110 Walker StreetNorth Sydney NSW 2060

P: (02) 9956 2666F: (02) 9959 3015

[email protected]

C:\r

vt\2

3218

6-A

-DM

SC

P S

HIF

TE

D C

EN

TR

AL_

rto.

rvt

14/1

2/20

15 1

0:33

:33

AM

1 : 500 TR

1

CARPARK SITE PLAN

MSC-HDR-AR-DG-10010232186

WESTMEAD MULTI STOREY CARPARK

ISSUE FOR TENDER

Cnr Institute Road and Darcy RoadWestmead NSW 2145

NSW HEALTHINFRASTRUCTURE

PRICE WATERHOUSECOOPERS

REV DESCRIPTION DRAWN CHECK DATE

1 TENDER RT TR 14/12/15

Page 3: Appendix C Architectural drawings

FIRE STAIR

FIRE STAIR

CP13CP12CP11CP10CP09CP08CP07CP06CP05CP04CP02

CPD

CP01

CPE

CPC

CPF

CPG

CPB

CPA

CPH

CP03

CP14

FIRE SPRINKLER ANDHYDRANT SYSTEMPUMP ROOM

BOOSTER

FIRE TRUCK ACCESS

PE

DE

ST

RIA

N P

AT

HW

AY

DA

RC

Y R

OA

D

BIK

E L

AN

E

WPM 1+

CON 3

PU

MP

PU

MP

RL 18.300

EXHAUSTFLUES

PAINTED.COLOUR TBC

RL 18.300

RAMPDOWN

RAMP 1 IN 20 MAX

RAMPUP

LIFT

LOBBY

RL 18.300

PAINTED CONCRETEWALL

WAYFINDING SIGNAGETO REAR WALL

40 SPACES MAX TOLG COMPARTMENT

ON SITEDETENTION

TANK BELOWSLAB. REFER TO

CIVIL ANDHYDRAULIC

DESIGN DETAILS

SMALLCARS

SMALLCARS

PEDESTRIAN WALKWAY TOLANDSCAPE ARCHITECTSDETAILS

LIGHTING COLUMNS TOELECTRICALSPECIFICATION

PEDESTRIAN ACCESSSTAIR FROM LG TO L6

ELEC ELEC FHR

EXTERNAL PAVINGCONTINUES INSIDE LIFTLOBBY

CONTINUOUS FIRE RATED WALLTO UNDERSIDE OF GROUNDFLOOR SLAB. BLK01 + PNT2

CONTINUOUS FIRE RATED WALLTO UNDERSIDE OF GROUNDFLOOR SLAB. BLK01 + PNT2

4 400 8 200 8 200 8 200 8 200 8 200 8 200 8 200 8 200 8 200 8 200 4 400 6 400

4 4

00

7 5

50

9 9

00

9 2

00

9 0

00

8 4

50

4 4

00

BIK 01

EXIT

EELEC

SMALLCARS

SMALLCARS

NOM. 4 DEMOUNTABLEBOLLARDS WITH FIRE

BRIGADE KEYING. QTY. TOSUIT APPROVED

HARDSTAND WIDTH

SLIDING FIRERATED SHUTTER

DLG

04

DLG

08.1

DLG

08.2

DLG

08.3

DLG

01

DLG

02

DLG10

DLG

05

DLG

06

1

DG-16010

DG-15010

2

DG-15010

1

DG-15020

1

DG-15020

2

1

DG-160201

DG-16030

1

DG-16040

2

DG-16040

DLG

07

PART HEIGHT WALLT.O.W. 1500 AFFL

CON 03+ PNT4

FIRESTAIR

01

FIRESTAIR

02

STAIR04

ALLOW FOR DRIVEWAYBARRIERS AS PER

EARLY WORKSLANDSCAPE DETAILS

BO

L 2

FRS

ALL LIFT PITS WITH DRAINED SUMPSAND COMPLIANT ACCESS

NOM RL 16.800. REFER TO VETICALTRANSPORTATION REPORTS

DP TRANSFERFROM ABOVE

TBC HYD. ENG.

DLG

03

DLG09

DLG

11

DLG

13

DLG

11

FW1

FW1

FW1 FW1

FW1

FW

2

FW1

FW

1

ALLOW FOR BUNDED, DRAINED CARWASHAREA AS PER HYD. ENG. DETAILS

FW1

FW2 FW2

SLIDING GLASS DOORS CW3FULL FACADE WIDTH STRIPDRAIN FW3

FW3 FW3FW3

CW2CW1CW1

HYDRANT TANK. TOHYD. ENG. DETAILS

SPRINKLERTANK.

REFER TOHYD. ENG.DETAILS

WPM 1+

CON 3

SPRINKLERTANK.

REFER TOHYD. ENG.DETAILS

WPM 1+

CON 3

CON T1,2,3

TAP 01

TAP 01 TAP 01

TAP 01

MIN1200mm CLEARBETWEEN MIDDLE

BOLLARDS. SUBJECT TOBCA + DDA REVIEW

BIK

01

BIK 01

BIK

01

PERIMETER DRAIN TOALL SUBMERGEDWALLS AS PERHYDRAULICENGINEERS + CIVILENGINEERSREQUIREMENTS. ALSOALLOW FOR INTERNALSPOON DRAIN ONOTHER SIDE OF WALLS

WPM 1+

CON 3

BOL 3

DPCONNECTIONFROM ABOVE.REFER TO HYD.ENG. DETAILS

DPCONNECTIONFROM ABOVE.REFER TO HYD.ENG. DETAILS

DPCONNECTIONFROM ABOVE.REFER TO HYD.ENG. DETAILS

DPCONNECTIONFROM ABOVE.REFER TO HYD.ENG. DETAILS

DPCONNECTIONFROM ABOVE.REFER TO HYD.ENG. DETAILS

DPCONNECTIONFROM ABOVE.REFER TO HYD.ENG. DETAILS

DP

CO-ORDINATEDP TOCLEAR FRS

DP DP DP

DPDP

AIRLOCK

DG-23040

2

PERIMETER DRAIN TOALL SUBMERGEDWALLS AS PERHYDRAULICENGINEERS + CIVILENGINEERSREQUIREMENTS. ALSOALLOW FOR INTERNALSPOON DRAIN ONOTHER SIDE OF WALLS

CON 01

SWITCHROOMDG13

DG

14

BLK

01

BLK01

CON 03

KIOSK SUBSTATIONAND PLINTH TO BEPLANTED AROUND

FW2

RA

MP

1 IN

20

MA

X

RL 18.000RL 18.000

RL 18.300

RL 18.470

RA

MP

1 IN

20

MA

X

RA

MP

1 IN

20

MA

X

RA

MP

1 IN

20

MA

X

RL 18.470

RL 18.300

FW1

FW1 FW1

FW1

FHR+HYD TBCFIRE ENG/FIRE

FHR+HYD TBCFIRE ENG/FIRE

FHR+HYD TBCFIRE ENG/FIRE

FHR+HYD TBCFIRE ENG/FIRE.

LOCATE INCUPBOARDS

PAYSTATIONZONE. ALLOWFOR POWER +

COMMS

CW3

PS

ALLOW FOR WPM1 UNDER ALLCONCRETE SLABS AND BEAMS INCONTACT AND PROXIMITY WITH

EARTH AND FILL

CON 03+ PNT2/4

ALLOW FOR WPM2 TO ALLVERTICAL SURFACES SUCH AS

WALLS AND COLUMNS INCONTACT WITH EARTH AND FILL

RAM

P 1

IN 4

0 M

AX

RA

MP

1 IN

20

MA

X

FALL AWAY FROMMSCP - 1 IN 40 MAX

RFM1

PLANNORTH TRUE

NORTH

SCALE:

DRAWING TITLE:

DRAWING NUMBER:

CHECKED:

THIS DOCUMENT IS THE COPYRIGHT OF THE HDR|RD GROUP (NSW) Pty.LtdALL THE INFORMATION ILLUSTRATED ON THIS DOCUMENT IS TO BE CHECKED AND VERIFIED ON SITE.IN THE EVENT OF DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK.DO NOT SCALE DRAWINGS ELECTRONICALLY OR MANUALLY

PROJECT NUMBER: ISSUE:

CLIENT:

Level 6, 77 Pacific HighwayNorth Sydney NSW 2060

P: (02) 9978 5427

www.hinfra.health.nsw.gov.au

F: (02) 8904 1377

PROJECT MANAGER:

Darling Park201 Sussex StreetSydney NSW 2000

P: (02) 8266 2750

www.pwc.com.au

F: (02) 8286 2750

NOT FOR CONSTRUCTION

DOHRS NUMBER:

5335

LEAD ARCHITECT:

Lvl 1, 110 Walker StreetNorth Sydney NSW 2060

P: (02) 9956 2666F: (02) 9959 3015

[email protected]

C:\r

vt\2

3218

6-A

-DM

SC

P S

HIF

TE

D C

EN

TR

AL_

rto.

rvt

14/1

2/20

15 1

0:33

:38

AM

1 : 200 TR

1

CARPARK LOWER GROUND

MSC-HDR-AR-DG-12010232186

WESTMEAD MULTI STOREY CARPARK

ISSUE FOR TENDER

Cnr Institute Road and Darcy RoadWestmead NSW 2145

NSW HEALTHINFRASTRUCTURE

PRICE WATERHOUSECOOPERS

1 : 2001Tender - Ground, Lower

0 10m2m 4m 6m 8m

NOTES:

ALL LINE MARKINGS ARE INDICATIVE ONLY. D&CCONTRACTOR TO ENSURE THAT INTEGRATEDWAYFINDING AND STATUTORY SIGNAGE COMPLIESWITH ALL RELEVANT STATUTORY REQUIREMENTS ANDANY ADDITIONAL REQUIREMENTS IN BCA, DDA, CIVIL,FIRE ENGINEERING

CAR SPACE SET OUT, TYPE AND SIZES TO BE READ INCONJUNCTION WITH TRAFFIC ENGINEERSDOCUMENTATION. QUANTITY AND LOCATION OF SMALLCAR SPACES AT THE ENDS OF RAMPS SUBJECT TOINDEPENDENT TRAFFIC AND CIVIL PEER REVIEWS

LOCATION OF FIRE HOSE REEEL AND HYDRANTS TO BEREAD IN CONJUNCTION WITH FIRE SERVICES, BCA ANDFIRE ENGINEERS DOCUMENTATION

FIRE RATED WALLS AS PER BCA AND FIREENGINEERS REQUIREMENTS. CONTRACTORRESPONSIBLE FOR CONFIRMING EXTENTS ANDCHECKING FOR DISCREPANCIES

REFER TO LEVEL 1 (DG-12030) FOR STANDARD NOTES,SETOUTS & FINISHES

REFER TO DG-00010 FOR CAR SPACE NUMBERS

REV DESCRIPTION DRAWN CHECK DATE

1 TENDER RT TR 14/12/15

Page 4: Appendix C Architectural drawings

FIRE STAIR

FIRE STAIR

CP13CP12CP11CP10CP09CP08CP07CP06CP05CP04CP02

CPDCPD

CP01

CPECPE

CPCCPC

CPFCPF

CPGCPG

CPBCPB

CPACPA

CPHCPH

CP03

CP14

EXISTING STAFF ENTRY

RAMPDOWN

RAMPUP RAMP 1 IN 20 MAX

2 ENTRY BOOM GATES

SLIDING GLASS DOORS CW3FULL FACADE WIDTH STRIP DRAIN FW3

BRIDGE LINK ABOVE ON LEVEL 2OF EXISTING DENTAL BUILDING

SMALLCARS

SMALLCARS

SM

ALL

CA

RS

SMALLCARS

SMALLCARS

SMALLCARS

SMALLCARS

SMALLCARS

SMALLCARS

SMALLCARS

EXIT

ELEC FHR

ELEC FHRELEC FHR

LIFT

LOBBY

4 400 8 200 8 200 8 200 8 200 8 200 8 200 8 200 8 200 8 200 8 200 4 400 6 400

4 4

00

7 5

50

9 9

00

9 2

00

9 0

00

8 4

50

4 4

00

E

3 V

ER

TIC

AL

BIK

E R

AC

KS

8 V

ER

TIC

AL

BIK

E R

AC

KS

MO

TO

RB

IKE

SMALLCARS

SMALLCARS

DG

01

DG

02

DG

03

DG

09

DG

10

DG

11

DG

05

DG

06

DG

07

1

DG-16010

DG-15010

2

DG-15010

1

DG-15020

1

DG-15020

2

1

DG-160201

DG-16030

1

DG-16040

2

DG-16040

?

AH 01

LOCATION TBCHYD. ENG.

AH 01

LOCATION TBCHYD. ENG.

AH 01

LOCATION TBCHYD. ENG.

AH 01

LOCATION TBCHYD. ENG.

AH 01

LOCATION TBCHYD. ENG.

FIRESTAIR

01

FIRESTAIR

03

FIRESTAIR

02

STAIR04

BIK

02

BIK

02

HR

01

HR

03

TAC01

TAC01

DP FROM ABOVETBC HYD. ENG.

DP FROM ABOVETBC HYD. ENG.

DP FROM ABOVETBC HYD. ENG.

DP FROM ABOVETBC HYD. ENG.

RL 21.250

RL 21.200

DG04

DG12

DG08

DG

15

CW1

CW2

CW2

CW1 CW1

FW1 FW1 FW1 FW1

FW1

FW1 FW1 FW1 FW1 FW1

FW1

FW1

FW

2

FW

2

FW3FW3

FW3FW3

HYDRAULIC ANDCIVIL TOCONFIRMDRAINAGEREQUIREMENTSAT ALL DOORSTO ORAL HEALTH

HYDRAULIC ANDCIVIL TOCONFIRMDRAINAGEREQUIREMENTSAT ALL DOORSTO ORAL HEALTH

HYDRAULIC ANDCIVIL TOCONFIRMDRAINAGEREQUIREMENTSAT ALL DOORSTO ORAL HEALTH

HYDRAULIC ANDCIVIL TOCONFIRMDRAINAGEREQUIREMENTSAT ALL DOORSTO ORAL HEALTH

HYDRAULIC AND CIVIL TOCONFIRM DRAINAGE

REQUIREMENTS AT ALLDOORS TO ORAL HEALTH

EXIT

2 400

SMALLCARS

CON 03

CON 03

FW3

FW1

FW1

FW1

RL 21.200

FHR+HYD TBCFIRE ENG/FIRE

SMALLCARS

PS

ENTRY ENTRY

ALLOW FOR WPM1 UNDER ALLCONCRETE SLABS AND BEAMS INCONTACT AND PROXIMITY WITH

EARTH AND FILL

NE

W D

RIV

EW

AY

EN

TR

Y F

RO

M D

AR

CY

RO

AD

STEP UP ONGROUND FLOORONLY. MAX 1:20

ALL LANDSCPAPE AND PATHWAYSBETWEEN MSCP AND DENTAL TO HAVEGRADES NOT EXCEEDING 1:33 AS PER

CIVIL AND LANDSCAPE DESIGN

EX

TE

RN

AL

ST

AIR

S(S

PO

1)

KIOSK AND PLINTHBELOW

RFM1

SP01

SP01

SP01

SP01 SP01SP01SP01

SP01 SP01

PLANNORTH TRUE

NORTH

SCALE:

DRAWING TITLE:

DRAWING NUMBER:

CHECKED:

THIS DOCUMENT IS THE COPYRIGHT OF THE HDR|RD GROUP (NSW) Pty.LtdALL THE INFORMATION ILLUSTRATED ON THIS DOCUMENT IS TO BE CHECKED AND VERIFIED ON SITE.IN THE EVENT OF DISCREPANCIES REFER TO ARCHITECT PRIOR TO COMMENCEMENT OF THE WORK.DO NOT SCALE DRAWINGS ELECTRONICALLY OR MANUALLY

PROJECT NUMBER: ISSUE:

CLIENT:

Level 6, 77 Pacific HighwayNorth Sydney NSW 2060

P: (02) 9978 5427

www.hinfra.health.nsw.gov.au

F: (02) 8904 1377

PROJECT MANAGER:

Darling Park201 Sussex StreetSydney NSW 2000

P: (02) 8266 2750

www.pwc.com.au

F: (02) 8286 2750

NOT FOR CONSTRUCTION

DOHRS NUMBER:

5335

LEAD ARCHITECT:

Lvl 1, 110 Walker StreetNorth Sydney NSW 2060

P: (02) 9956 2666F: (02) 9959 3015

[email protected]

C:\r

vt\2

3218

6-A

-DM

SC

P S

HIF

TE

D C

EN

TR

AL_

rto.

rvt

14/1

2/20

15 1

0:33

:44

AM

1 : 200 TR

1

CARPARK GROUND FLOOR

MSC-HDR-AR-DG-12020232186

WESTMEAD MULTI STOREY CARPARK

ISSUE FOR TENDER

Cnr Institute Road and Darcy RoadWestmead NSW 2145

NSW HEALTHINFRASTRUCTURE

PRICE WATERHOUSECOOPERS

1 : 2001Tender - Ground

0 10m2m 4m 6m 8m

NOTES:

ALL LINE MARKINGS ARE INDICATIVE ONLY. D&CCONTRACTOR TO ENSURE THAT INTEGRATEDWAYFINDING AND STATUTORY SIGNAGE COMPLIESWITH ALL RELEVANT STATUTORY REQUIREMENTS ANDANY ADDITIONAL REQUIREMENTS IN BCA, DDA, CIVIL,FIRE ENGINEERING

CAR SPACE SET OUT, TYPE AND SIZES TO BE READ INCONJUNCTION WITH TRAFFIC ENGINEERSDOCUMENTATION. QUANTITY AND LOCATION OF SMALLCAR SPACES AT THE ENDS OF RAMPS SUBJECT TOINDEPENDENT TRAFFIC AND CIVIL PEER REVIEWS

LOCATION OF FIRE HOSE REEEL AND HYDRANTS TO BEREAD IN CONJUNCTION WITH FIRE SERVICES, BCA ANDFIRE ENGINEERS DOCUMENTATION

FIRE RATED WALLS AS PER BCA AND FIREENGINEERS REQUIREMENTS. CONTRACTORRESPONSIBLE FOR CONFIRMING EXTENTS ANDCHECKING FOR DISCREPANCIES

REFER TO LEVEL 1 (DG-12030) FOR STANDARD NOTES,SETOUTS & FINISHES

REFER TO DG-00010 FOR CAR SPACE NUMBERS

REV DESCRIPTION DRAWN CHECK DATE

1 TENDER RT TR 14/12/15