2
Scope of delivery 1 EP Single Jig #JE1067 4 Syringes with Luer-Lock, 20ml ® EP Single Jig The following cartridges can be refilled in the Jig: T0691, T0692, T0693, T0694 T0711, T0711H, T0712, T0713, T0714 T0731, T0732, T0733, T0734 T0771, T0772, T0773, T0774, T0775, T0776 T0781, T0782, T0783, T0784, T0785, T0786 T0791, T0792, T0793, T0794, T0795, T0796 T0891, T0892, T0893, T0894 T0801, T0802, T0803, T0804, T0805, T0806 T0811, T0812, T0813, T0814, T0815, T0816 T0821, T0822, T0823, T0824, T0825, T0826 T0870, T0871, T0872, T0873, T0874, T0875, T0876, T0877, T0878, T0879 T0881, T0882, T0883, T0884 T0961, T0962, T0963, T0964, T0965, T0966, T0967, T0968, T0969 T0971 T0981, T0982, T0983, T0984, T0985, T0986 T0991, T0992, T0993, T0994, T0995, T0996 T1001, T1002, T1003, T1004 T1241, T1242, T1243, T1244 T1251, T1252, T1253, T1254 T1261, T1262, T1263, T1264 T1271, T1272, T1273, T1274 T1281, T1282, T1283, T1284 T1291, T1292, T1293, T1294 T1301, T1302, T1303, T1304 T1301, T1302, T1303, T1304 © 2013 Jens Rogge

Upload: others

Post on 30-Oct-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Anleitung EP Single Jig EN - R -JetTek · Scope of delivery 1 EP Single Jig #JE1067 4 Syringes with Luer-Lock, 20ml EP Single Jig ® The following cartridges can be refilled in the

Scope of delivery

1 EP Single Jig #JE10674 Syringes with Luer-Lock, 20ml

®

EP Single Jig

The following cartridges can be refilled in the Jig:

T0691, T0692, T0693, T0694T0711, T0711H, T0712, T0713, T0714T0731, T0732, T0733, T0734T0771, T0772, T0773, T0774, T0775, T0776T0781, T0782, T0783, T0784, T0785, T0786T0791, T0792, T0793, T0794, T0795, T0796T0891, T0892, T0893, T0894T0801, T0802, T0803, T0804, T0805, T0806T0811, T0812, T0813, T0814, T0815, T0816T0821, T0822, T0823, T0824, T0825, T0826T0870, T0871, T0872, T0873, T0874, T0875, T0876, T0877, T0878, T0879T0881, T0882, T0883, T0884T0961, T0962, T0963, T0964, T0965, T0966, T0967, T0968, T0969T0971T0981, T0982, T0983, T0984, T0985, T0986T0991, T0992, T0993, T0994, T0995, T0996T1001, T1002, T1003, T1004T1241, T1242, T1243, T1244T1251, T1252, T1253, T1254T1261, T1262, T1263, T1264T1271, T1272, T1273, T1274T1281, T1282, T1283, T1284T1291, T1292, T1293, T1294T1301, T1302, T1303, T1304T1301, T1302, T1303, T1304

© 2013 Jens Rogge

Page 2: Anleitung EP Single Jig EN - R -JetTek · Scope of delivery 1 EP Single Jig #JE1067 4 Syringes with Luer-Lock, 20ml EP Single Jig ® The following cartridges can be refilled in the

®

4. Fill the syringe with 20 ml of air and attach it onto the Jig’s cap.Now press air into the cartridge until you hear a soft click noise.You will need some energy. In most cases the click will happenif you have compressed the air in the syringe to a volumebetween 5 and 10 ml! Then dismount the syringe.This has to be done only ONCE per cartridge BEFORE youperform the FIRST REFILL!

EP Single Jig

CLICK!

2. Open the Jig and insert the cartridge upside-down.Make sure that the cartridge is moved to the back panel,otherwise the filler neck will be damaged.

3.

Close the quick clamp.

Close the cap carefully. The filler neckhas to be adapted into the ink outlet.

6. Turn the Jig back onto the base and dismount the syringe.Open the quick clamp. The cartridge will be stucked to thefiller neck. .

Now the cartridge is refilled.

Remove it carefully

5. Fill the syringe with the wanted amount of inkand remove the air out of it. Fix it onto the Jig.Now turn the Jig onto the front side and slowlypress the ink into the cartridge.

IMPORTANT NOTICE:Because the filler neck is a very sensitivecomponent of the Jig, we cannot acceptguarantee at wrong handling or mechanicaldamage!

1. Because you cannot see how many ink is still in a used cartridge, it isimportant to evacuate the old ink. Skipping this step will cause overfillingand leakage. You can use the EP Single Jig for this process.