an-80i quick install guide

12
70-00074-01-04 Proprietary Redline Communications ©2007 August 15, 2007 Page 1 of 12 AN-80i PTP System Quick Install Guide

Upload: matoriz

Post on 22-Jun-2015

37 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: An-80i Quick Install Guide

70-00074-01-04 Proprietary Redline Communications ©2007 August 15, 2007 Page 1 of 12

AN-80i PTP System

Quick Install Guide

Page 2: An-80i Quick Install Guide

RedCONNEXTM AN-80i PTP Quick Install Guide

70-00074-01-04 Proprietary Redline Communications © 2007 August 15, 2007 Page 2 of 12

Copyright Information All rights reserved August 15, 2007. The information in this document is proprietary to Redline Communications Inc. This document may not in whole or in part be copied, reproduced, or reduced to any medium without prior consent, in writing, from Redline Communications Incorporated.

Copyright © 2007 Redline Communications Inc.

Contact Information: Redline Communications Inc. 302 Town Centre Blvd. Suite 100 Markham, ON Canada L3R 0E8 Web site: http://www.redlinecommunications.com Sales Inquiries: North American [email protected] Toll-free sales 1-866-633-6669 International [email protected] Support: www.redlinecommunications.com/support/support_portal.html

Document Control: 70-00074-01-03-AN-80i_Quick_Install_Guide-20070815a.doc

Disclaimer Every effort has been made to ensure the accuracy of the material provided herein; however, Redline assumes no responsibility regarding the use of the material. Additionally, Redline makes no representations or warranties, either expressed or implied, regarding the contents of this product. Redline Communications shall not be liable for any misuse regarding this product.

Page 3: An-80i Quick Install Guide

RedCONNEXTM AN-80i PTP Quick Install Guide

70-00074-01-04 Proprietary Redline Communications © 2007 August 15, 2007 Page 3 of 12

Table of Contents 1 Safety Notices .................................................................. 3 2 Important Service Information........................................ 3 3 Test Overview................................................................... 4 3.1 Required Test Facilities ............................................... 4 3.2 Required Test Equipment............................................ 7 4 Assemble and Configure AN-80i .................................... 7 5 Configure AN-80i Systems.............................................. 7 6 Field Installation Instructions ......................................... 9

Table of Figures Figure 1: AN-80i Indoor Test Connection Diagram .................. 5 Figure 2: AN-80i Outdoor Test Connection Diagram ............... 6 Figure 3: Configuration - Options Key ...................................... 8 Figure 4: Mounting the AN-80i Antenna ................................... 9

11 SSaaffeettyy NNoottiicceess 1. Do not exceed the described limits on product labels. Position power cords

to avoid damage. Do not overload wall outlets. Protect equipment by disconnecting power when not in use.

2. Do not place PoE power adaptor on or near a direct heat source or operate near water or in a wet location. Disconnect the PoE power before cleaning and use only a damp cloth for cleaning. Do not use liquid or aerosol cleaners.

3. The AN-80i unit must not be located near power lines or other electrical power circuits.

4. The AN-80i must be properly grounded to protect against power surges and accumulated static electricity. It is the user's responsibility to install this device in accordance with the local electrical codes and building codes: grounding of the transceiver unit, mast, lead-in wire and discharge unit, location of discharge unit, size of grounding conductors and connection requirements for grounding electrodes.

22 IImmppoorrttaanntt SSeerrvviiccee IInnffoorrmmaattiioonn 1. Refer all repairs to qualified service personnel. Do not remove the covers or

modify any part of this device, as this voids the warranty. 2. Locate the serial numbers and record these on your registration card for

future reference. Record the MAC address located on the AN-80i.

Page 4: An-80i Quick Install Guide

RedCONNEXTM AN-80i PTP Quick Install Guide

70-00074-01-04 Proprietary Redline Communications © 2007 August 15, 2007 Page 4 of 12

33 TTeesstt OOvveerrvviieeww This Quick Install Guide provides steps for basic configuration and operational testing of an AN-80i PTP link. This procedure assumes a setup consisting of two complete AN-80i units. Refer to the AN-80i User Manual and Installation Guidelines for additional safety instructions and for specific operational and installation details.

3.1 Required Test Facilities You will require the following to perform these tests:

1. Identify the RF channel(s) to be used. 2. Obtain a valid Options Key for each AN-80i unit. This key (string of

numbers, letters, and dashes) must be entered into AN-80i configuration to allow full operation of the wireless link.

3. Record the MAC address for each system to be tested/installed (label on AN-80i units). The MAC address is needed to identify each AN-80i and select the correct Options Key to be entered.

4. One or two PCs each having an Ethernet interface port, Web browser software installed (Internet Explorer recommended), and a CAT-5 cross-over Ethernet cable for each PC.

5. A location with adequate space and power facilities. 6. To satisfy FCC and IC RF exposure requirements for RF transmitting

devices, the following distances should be maintained between the antenna of this device and persons during device operation:

Table 1: FCC & IC RF Recommended Safe Separation Distances

Frequency Separation Distance 5.4 GHz 40 centimeters or more

5.8 GHz 20 centimeters or more (PMP) 310 centimeters or more (PTP)

7. Redline does not endorse testing indoors with antennas. The operation of antennas in close proximity results in poor connectivity due to high RF multipath effect and RF saturation may damage equipment. Indoor testing may require the use of an RF chamber. When performing indoor testing the RF outputs from each AN-80i can be connected together through a static/variable attenuator. Refer to the connection diagrams on the following page.

Page 5: An-80i Quick Install Guide

RedCONNEXTM AN-80i PTP Quick Install Guide

70-00074-01-04 Proprietary Redline Communications © 2007 August 15, 2007 Page 5 of 12

Figure 1: AN-80i Indoor Test Connection Diagram

Page 6: An-80i Quick Install Guide

RedCONNEXTM AN-80i PTP Quick Install Guide

70-00074-01-04 Proprietary Redline Communications © 2007 August 15, 2007 Page 6 of 12

Figure 2: AN-80i Outdoor Test Connection Diagram

,

Page 7: An-80i Quick Install Guide

RedCONNEXTM AN-80i PTP Quick Install Guide

70-00074-01-04 Proprietary Redline Communications © 2007 August 15, 2007 Page 7 of 12

3.2 Required Test Equipment 1. PC#1: Use a crossover CAT-5 Ethernet cable to connect PC#1 to the PoE

Data In port on the AN-80i. Equipped with a Web browser (requires Internet Explorer 6.0 or higher), and Ethernet port for connection to AN-80i (PTP Slave). The IP address/subnet mask must be set for the same subnet as the AN-80i. Recommended IP settings are: IP address = 192.168.25.22, Net Mask = 255.255.255.0

2. PC#2: Use a crossover CAT-5 Ethernet cable to connect PC#2 to the PoE Data In port on the AN-80i. Equipped with a Web browser and Ethernet port for connection to AN-80i (PTP Master). The IP address/subnet mask must be set for the same subnet as the AN-80i. Recommended IP settings are: IP address = 192.168.25.23, Net Mask = 255.255.255.0

44 AAsssseemmbbllee aanndd CCoonnffiigguurree AANN--8800ii Unpack the AN-80i and connect all components according to the Quick Test wiring diagrams on page 5. Do not power-on the AN-80i unit at this time.

PoE Caution -- Warning to Service Personnel: 48 VDC Customer equipment including personal computers, routers, etc., must be connected only to the INPUT (DATA) port on the PoE unit. Only the outdoors Ethernet interface cable connecting to the AN-80i can be safely connected to the OUTPUT (DATA & POWER) connector. Connecting customer premises Ethernet equipment directly to the OUTPUT (DATA & POWER) connector on the Power-over-Ethernet power adapter may damage customer equipment.

55 CCoonnffiigguurree AANN--8800ii SSyysstteemmss 1. Enter the AN-80i Options Key a) Use an Ethernet cable to connect the PC #1 (192.168.25.22) to the INPUT

port of the PoE power adapter. b) Power-on the AN-80i by connecting AC power to the PoE power adapter. c) On the PC, open a browser and enter the default IP address (192.168.25.2).

Login to the AN-80i using the factory defaults: Username: admin Password: admin

d) Click Product Options in the left hand menu of the Web screen and enter the options key for the this AN-80i unit. Every options key is unique to the MAC address of an AN-80i and keys cannot be reused. Option keys are provided by your local Redline equipment supplier. The options key enables AN-80i features including the maximum Uncoded Burst Rate (UBR) and frequency ranges (region codes). Without the options key, only very limited operation is possible (restricted power, UBR, and frequency selection).

Page 8: An-80i Quick Install Guide

RedCONNEXTM AN-80i PTP Quick Install Guide

70-00074-01-04 Proprietary Redline Communications © 2007 August 15, 2007 Page 8 of 12

Figure 3: Configuration - Options Key

Important: If an AN-80i is placed in-service without first entering a purchased permanent Options Key -- the wireless link will experience a service outage.

2. Configure the AN-80i For each link, one AN-80i unit must be designated as 'PTP Master' and the second unit as 'PTP Slave'. When powered-on, the PTP Master will actively transmit to establish a link with the (passive) PTP Slave. Click Configure System in the left hand menu of the Web screen and make the recommended settings for each AN-80i. It is recommended to first configure the PTP Slave.

Table 2: Web - Recommended Settings Setting PTP Slave PTP Master

IP Address 192.168.25.2 192.168.25.3 RF Freq. (MHz) Must match Master

RF setting Set RF according to

network design ATPC Enable (Disabled) (Disabled) Adaptive Modulation (Enabled) (Enabled) System Mode PTP Slave PTP Master Encryption Type None None Link Length Measurement Mode

Automatic Automatic

Radio Enable (Enabled) (Enabled)

After making these settings, click Save at the bottom of the configuration screen. If the IP address was changed, you must change the address entered in the Web browser to match the new AN-80i IP address. Repeat steps 1 & 2 to configure the PTP Master AN-80i using the second test PC (192.168.25.23) if available. If only one PC is used, move the PC#1 Ethernet connection to the second PoE power adapter.

Page 9: An-80i Quick Install Guide

RedCONNEXTM AN-80i PTP Quick Install Guide

70-00074-01-04 Proprietary Redline Communications © 2007 August 15, 2007 Page 9 of 12

3. Test the Wireless Connection The AN-80i units should now be operating on the same RF channel and will automatically negotiate a wireless connection. Use the following steps to verify connectivity: a) From PC #2, enter the IP address of the PTP Slave AN-80i (192.168.25.2) into the Web browser and login to the AN-80i unit. b) On PC #2, open a command line window and use the following command to send a ping message to PC#1 (192.168.25.22) over the wireless interface. ping 192.168.25.22 You should observe a result similar to the following: Reply from 192.168.25.22: bytes=32 time=1ms TTL=63

66 FFiieelldd IInnssttaallllaattiioonn IInnssttrruuccttiioonnss These steps should be performed after successfully completing the pre-installation tests and configuration.

1. Install AN-80i Install the AN-80i, mounting bracket, and antenna on the mast. Connect the outdoor Ethernet cable from the AN-80i to the indoor PoE power adapter.

Important: Ethernet Plug Must 'Click' into Socket When inserting the RJ-45 plug, you should hear an audible 'click' from the plastic locking mechanism. Ensure the connector is locked before sealing and weatherproofing the AN-80i. Do not use cables where this locking mechanism is broken or has been removed!

Always follow local and national electrical and building codes for grounding and safety. If you have determined that it is appropriate to install lightning protection for your system, refer to the AN-80i Installation Guidelines manual for additional information.

Figure 4: Mounting the AN-80i Antenna

Page 10: An-80i Quick Install Guide

RedCONNEXTM AN-80i PTP Quick Install Guide

70-00074-01-04 Proprietary Redline Communications © 2007 August 15, 2007 Page 10 of 12

2. Verify Free Channel (Spectrum Sweep) It is recommended to check that the planned RF channel is available at the deployment site. A spectrum sweep must be performed from both ends of the link. When performing a sweep from the PTP Slave, the PTP Master must be powered-off or have the transmitter disabled. The PTP Slave will remain passive during a spectrum sweep from the PTP Master.

a) Login to the AN-80i Web interface and click Spectrum Sweep in the left hand menu.

b) Enter the Start Frequency, End Frequency, and Step (multiple of 2.5 MHz) for the spectrum to be scanned. Set the No of Acquisitions to '10' and click the Start button to begin the scan.

c) After reviewing the results, enter a narrower frequency scan and higher sample value to monitor a potentially clear channel.

d) Repeat the spectrum sweep from the remote-end AN-80i. Note: It is also recommended to use the Redline RF Monitoring Tool. This PC-based application continuously polls both ends of a wireless link and graphs the RSSI and SINADR values in real time. Contact your Redline sales representative to obtain this useful deployment and troubleshooting tool.

3. Align Antennas a) Align each antenna in azimuth and elevation plane. Verify that RSSI values

at the base station and subscriber match your link budget predictions. If the RSSI is not within 5 dB of the expected value, recheck the antenna alignment and ensure there are no obstructions in the RF path. Record RSSI/CINR as reference values.

b) If desired, you can enable the antenna alignment buzzer. This feature provides an audible signal of the received signal strength (stronger signal->faster repetitions). Click Configure System in the left hand menu of the Web screen and make the following setting: Antenna Alignment Buzzer Enable: (Enabled) The buzzer remains active until disabled by the operator.

4. Connect AN-80i to the Network You should make all necessary changes to the AN-80i subscriber station configuration before connecting to the network. Use a CAT-5 Ethernet cable to connect the data network to the Data In port on the PoE power adapter. Refer to the AN-80i User Manual and AN-80i Installation Guidelines manual for further details.

Page 11: An-80i Quick Install Guide

RedCONNEXTM AN-80i PTP Quick Install Guide

70-00074-01-04 Proprietary Redline Communications © 2007 August 15, 2007 Page 11 of 12

Notes:

Page 12: An-80i Quick Install Guide

70-00074-01-04 Proprietary Redline Communications © 2007 August 15, 2007 Page 12 of 12

302 Town Centre • Suite 100 • Markham, Ontario • Canada • L3R 0E8 www.redlinecommunications.com

Copyright ©2007 Redline Communications Inc. All rights reserved. The information in thisdocument is subject to change without notice. The statements, configurations, technical data,and recommendations in this document are believed to be accurate and reliable, but arepresented without express or implied warranty. Users must take full responsibility for theirapplications of any products specified in this document. The information in this document isproprietary to Redline Communications Inc.