Page0 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
REVISED March 15, 2016
[CompanyL
Page1 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
CaliBamboo6675MesaRidgeRd.#100SanDiegoCA92121(888)788-2254Aminimumof120squarefeet(ft2)eachofsolidstrandbambooplankflooringandsheetcorkunderlaymentweresubmittedtothislaboratoryforSoundTransmissionClass(STC)andImpactInsulationClass(IIC)testing.Additionalsampledetailsareasfollows:• Flooring:CaliBambooAntiqueJavaFossilizedWideClickBambooFlooring,5-5/16”Widex9/16”Thickx72-7/8”Long,ModelNumber7004001100
• CorkUnderlayment:GreenClaimed®Premium+CorkUnderlayment,2.5mm,107.25squarefeet(ft2)perroll,ModelNumber1102002300
AtCaliBamboorequest,BenchmarkInternational,LLC(BMI)independentlycommissionedtestingbyalaboratoryaccreditedinaccordancewiththerequirementsdefinedorreferencedinISO/IEC17025:2005GeneralRequirementsforthecompetenceoftestingandcalibrationlaboratoriestoperformthespecifiedtestmethodsasfollows:• SoundTransmissionClass(STC):ASTME90-09,StandardTestMethodforLaboratoryMeasurementofAirborneSoundTransmissionLossofBuildingPartitionsandElements.TestresultswerethenclassifiedinaccordancewithASTME413-10,Classification for Rating Sound Insulation.
• ImpactInsulationClass(IIC):ASTME492-09,StandardTestMethodforLaboratoryMeasurementofImpactSoundTransmissionthroughFloor-CeilingAssembliesUsingtheTappingMachine.TestresultswerethenclassifiedinaccordancewithASTME989-06(Reapproved2012),StandardClassificationforDeterminationofImpactInsulationClass(IIC).
Thesubmittedflooringandunderlaymentsampleswereassembledpermanufacturerinstructionsandtestedtogetherasasystem.Testresults,toincludeadditionaldetailsregardingthetestmethodsusedandtestconditions/parametersapplied,isattachedinAppendixAandAppendixBofthisreport.• AppendixA:SoundTransmissionClass(STC),LaboratoryReportNumber102497488CRT-001c• AppendixB:ImpactInsulationClass(IIC),LaboratoryReportNumber102497488CRT-001d
Testresultsapplyonlytothereferencedflooringandunderlaymentsystemusingthespecifiedtestmethodsandconditionsidentifiedinthetestreport.Testresultsmaynotbeappliedtootherproducttypesorflooring/underlaymentsystemsunlessotherwisespecified.
Page2 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
ThisreporthasbeenproducedfortheexclusiveuseofCaliBamboo,andmaynotbereproducedexceptinitsentirety,andonlywiththeexpressed,writtenapprovalofBenchmarkInternational(BMI).NooneotherthanBMI’sclientshallbeentitledtorelyuponthisreportortheinformationcontainedherein;anysuchunauthorizedrelianceonoruseofthisreportwillbeatthethirdparty’ssolerisk.Servicesperformedforthisprojecthavebeenconductedwithalevelofcareandskillordinarilyexercisedbymembersoftheprofessioncurrentlypracticinginthisareaundersimilarconditionsandrestraints.Nowarranty,expressedorimplied,ismade.RespectfullySubmitted,
ChrisBattinManagingDirector,CertificationandTestServicesBenchmarkInternational,LLC(BMI)2710West5thAve.Eugene,Oregon97402
Page3 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
APPENDIXA:SOUNDTRANSMISSIONCLASS(STC)
Page4 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
Page5 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
Page6 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
Page7 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
Page8 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
Page9 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
APPENDIXB:IMPACTINSULTATIONCLASS(IIC)
Page10 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
Page11 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
Page12 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
Page13 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
Page14 Project#:0721341-263
Lab#:2016-0792Date:REVISED3/15/2016
top related