AC Power Solutions
Outdoor Uninterruptible Power SuppliesIndoor Uninterruptible Power SuppliesBackup Power SolutionsEnclosuresBatteriesGeneratorsAccessoriesCustom Solutions
AlphaTechnologiesLtd.
AlphaTechnologiesLtd.develops,manufacturesandmarketsindoorandoutdoorUPSandACBackupPowersolutionsandprovides
market specific products for the Telecom, DataComm, Traffic, Parking, Medical, and Security markets. Alpha also works in partnership
with globally recognized companies to provide customized OEM solutions.
Alpha products and solutions are known for their high-quality, feature-rich systems that are engineered to meet industry requirements and
withstandharshenvironmentalconditions.Sales,service,andmaintenanceisavailablethroughanetworkofdedicatedcenters
worldwide24/7.
AlphaTechnologiesLtd.isamemberofTheAlphaGroup.
TheAlphaGroup
The Alpha Group represents an alliance of independent companies who share a common philosophy – to create world class Total Power
Solutions.
Collectively, The Alpha Group is a leader in the power industry with thirty years of outdoor power expertise, and over two million systems
installed globally. Its members develop and manufacture AC and DC power conversion, protection, and standby products. Applications for
theseproductsincludebroadband,telecom,AC/UPS,commercial,industrial,anddistributedgeneration,foraworldwidecustomerbase.
AlphaGroupcompaniesalsoprovidearangeofinstallation,serviceandmaintenanceservices.
Members of The Alpha Group include Alpha Technologies Inc., Alpha Technologies Ltd., Alpha Energy, Alpha Industrial Power, Argus
Technologies, and G.B. Enterprises.
AboutAlpha
Power Solutions for Outdoor and Harsh Environments ......................................... 3
Novus FXM ................................................................................................................. 4
Communications and Monitoring ................................................................................ 5
Novus Micro Secure 100 ............................................................................................. 6
Alpha Novus Micro, Micro XL, Micro XL3 ................................................................... 7
Transfer and Bypass Switches .................................................................................... 8
Batteries and Accessories ...................................................................................... 9
AlphaCell™ Gold and GXL ........................................................................................ 10
AlphaCell™ AGM ...................................................................................................... 12
AlphaCell™ FT .......................................................................................................... 13
AlphaCell™ SMU HR ................................................................................................ 14
Battery Accessories .................................................................................................. 15
Generators ............................................................................................................ 17
AlphaGen™ DCX 3000 ............................................................................................. 18
AlphaGen™ Curbside ............................................................................................... 19
Enclosures ............................................................................................................ 21
Alpha Outdoor Enclosure Side Mount 6 ................................................................... 22
Alpha B4 ................................................................................................................... 23
Flextra P Series ......................................................................................................... 24
Flextra U Series ......................................................................................................... 25
Flextra Z Series ......................................................................................................... 26
Flextra Node.............................................................................................................. 27
Radium Mini Bay ....................................................................................................... 28
Indoor Solutions ................................................................................................... 29
Indoor UPS Topology ................................................................................................ 30
ALI Elite ..................................................................................................................... 32
ALI Elite XL ................................................................................................................ 34
ALI Elite Extended Run Time Battery Pack ............................................................... 35
Pinnacle Plus ............................................................................................................ 36
Pinnacle Plus High Power ......................................................................................... 38
CFR ........................................................................................................................... 40
AlphaMED®............................................................................................................... 43
Comet ....................................................................................................................... 45
Galaxy 4000 .............................................................................................................. 47
Galaxy 3000 .............................................................................................................. 49
Electrical Receptacles .......................................................................................... 51
Service .................................................................................................................. 52
Uninterruptible Power Supply Selection Guide .................................................... 53
Table of Contents
Alpha AC Catalogue 2008 For Prin1 1 7/30/2008 3:02:14 PM
Alpha AC Catalogue 2008 For Prin2 2 7/30/2008 3:02:14 PM
Power Solutions for Outdoor and Harsh EnvironmentsAlpha Technologies Ltd. specializes in providing AC power solutions for harsh environments. With over 30 years of experience in the global outdoor market, Alpha is positioned as the leader in providing rugged AC powering solutions, including hardened outdoor enclosures, uninterruptible power supply (UPS) modules, specialty batteries, battery accessories and generators to a large and recognizable customer base.
A truly rugged UPS system has many unique characteristics including conformal coated PCBs which protect against exposure to moisture, high levels of humidity and dust, carefully selected components to operate fully in extreme temperatures and boards designed to minimize environmental impact. In addition, products and solutions are designed to meet, outdoor installation, shock and vibration, standards. Systems must be designed to operate under extreme temperature conditions. Because Alpha understands these requirements, the Novus line of outdoor products is capable of withstanding extreme temperatures.
Alpha’s powering solutions also offer superior communications capabilities including remote monitoring via SNMP web-based communication. Real-time alerts and reports on UPS status can be sent to four different email addresses, or can be monitored from your PC, Internet-connected mobile phone or PDA, each with selectable event severity levels to trigger different notifications of events, faults and alarms.
Alpha’s power solutions for harsh environments have been used across the world for the last 30 years, operating with great reliability to ensure that mission-critical applications remain working even in times of unstable and unreliable power.
Alpha AC Catalogue 2008 For Prin3 3 7/30/2008 3:02:14 PM
Clean, uninterruptible backup power ensures your system will remain running during power outages
Wide range Automatic Voltage Regulation without going to batteries lengthens battery life, even during periods of surge or sag in the line voltage
External communications via RS-232 port or (optional) Ethernet SNMP interface provides local or remote monitoring and control
Independently programmable and dry contact relays allow tracking and controlling of key functions
Event and alarm logging with time and date stamping simplifies and accelerates troubleshooting
A wide operating temperature range of -40º to 74ºC (-40º to 165ºF) is suitable for the most extreme operating environments
Control and power connection panels can be rotated for mounting and display in any orientation for viewing convenience
Temperature compensated battery charging protects batteries from over charging at extreme temperatures, extending the life of the battery
Novus FXM power modules provide constant, reliable UPS grade backup power management for Traffic, Security, Telecommunications and other applications. The FXM can operate in temperatures of -40°C to 74°C (-40°F to 165°F) supporting your mission critical applications with clean, uninterruptible power. The FXM modules are CSA and UL approved and are adaptable for vertical1 or horizontal orientations as well as rack mounting. Double buck and Double boost is designed into the module to accept a wider input range, providing constant output voltage without switching to system batteries. The FXM’s built-in communications intelligence software reports UPS event status, collects valuable planning and maintenance data, and monitors your site, through a Windows-based GUI. It also offers a real-time clock for statistical analysis and event diagnostics. An optional SNMP Ethernet interface is available for remote monitoring from virtually any internet-supported location.
Agency Compliance
Electrical safety: UL1778, CSA 22.2 No 107.3-03
Marks: CCSAUS /CE*
EMI: Class A FCC/CISPR [EN 50091-2:1995] *CE applies to 230 VAC version only
Power Module: FXM 650 FXM 1100 FXM 2000
North America International North America International North America International
Battery String Voltage: 24VDC/48VDC 24VDC 48VDC 48VDC 48VDC 48VDC
Nominal Voltage: 120VAC 230VAC 120VAC 230VAC 120VAC 230VAC
Nominal Frequency: auto-sensing
Input Current: 8.7A 4.5A 15.5A 8.0A 20.0A 32A
Input Voltage Range: 85-175VAC 150-328VAC 85-175VAC 150-328VAC 85-150VAC 150-281VAC
Output Current: 5.8A 3.0A 9.9A 5.1A 17.9A 9.4A
Output Voltage Regulation +/- 10% over input voltage range
Output power at 50°C: 650W/VA 650W/VA 1100W/VA 1100W/VA 2000W/VA 2000W/VA
WxHxD 17”x3.47”x9”
432x88x229mm
15.5”x5.22”x8.75”
394x133x222mm
15.5”x5.22”x8.75”
394x133x222mm
Weight25lb/30lb for 48V
11kg
35lb
16kg
35lb
16kg
Specifications
Alpha Novus FXM
Outdoor SolutionsNovus FXM 650, 1100, 2000
4
Out
do
or
So
luti
ons
Alpha AC Catalogue 2008 For Prin4 4 7/30/2008 3:02:14 PM
Novus User Software
Novus User Software is a graphical user interface (GUI) designed to help Alpha UPS users monitor, control and set various parameters for their UPS systems through a computer using a standard RS-232 connection or through the internet when the UPS is equipped with an Ethernet/SNMP card. Users are able to read and display UPS events, warnings, date, time and relay configurations through this Windows-based environment. The software is an excellent maintenance and troubleshooting tool that automatically updates information every five seconds and records events and warnings with time/date stamps.
Get real-time notification of every alarm and fault that occurs so that you are immediately in a position to take action. Easy to customize to your exact needs, the Ethernet edition allows you to set your own notification preferences via PC and receive notifications to any PC, mobile phone, PDA, or any device that accepts email.
Ethernet/SNMP Card Option - Novus FXM, Novus Micro, Novus Micro Secure
For greater effectiveness, control and communication over your UPS system, choose the Ethernet/SNMP card option that is available for our Novus FXM, Novus Micro and Novus Micro Secure products. The Ethernet/SNMP card is factory installed allowing for communication with the Alpha UPS remotely through a web based interface. The Ethernet/SNMP card is powered by the UPS batteries eliminating the need for an external power source. The communication card is capable of providing notifications to four different email addresses and to devices such as your PC, a mobile phone or PDA. Outgoing notifications can be customized with selectable severity levels and triggered by events, faults and/or alarms.
User’s PC(using Web browser)
SNMP Server
InternetIntranet
On-SiteEthernet
ConnectionEthernet Port
Crossover Cable FXM
UPSFXM
MonitorCard
User’s PC(using Web browser for Ethernet connection to
on-site computer)
Outdoor SolutionsCommunications and Monitoring
5
Outd
oo
r So
lutions
Alpha AC Catalogue 2008 For Prin5 5 7/30/2008 3:02:15 PM
Nominal Specifications
Power Module Novus Micro Secure
North America International
Battery String Voltage 24VDC 24VDC
Nominal Voltage 120VAC 230VAC
Nominal Frequency 60Hz 50Hz
Input Current 2.0A 1.0A
Input Voltage Range 85 – 150VAC 154 – 323VAC
Output Current 0.83A @ 120VAC
4.2A @ 24VAC 0.43A @ 230VAC 230VAC
4.2A @ 24VAC 60Hz 50Hz
WxHxD 15”x11.5”x6”
381x292x152mm
Weight (with 4 9Ah batteries)
45lb / 20.4kg
Run Time* 2 hrs 15 mins
* Run time on battery power can vary based on loads, temperature and battery. Other battery options are available.
All weather protection with durable outdoor NEMA 3R rated plastic enclosure
Enhanced battery life with wide-range Automatic Voltage Regulation
Local or remote monitoring and control through RS-232 port or (optional) SNMP Ethernet interface
Tracking and controlling of key functions through independently programmable relays
Simplified troubleshooting through event and alarm logging with time and date stamping
Maximum mounting flexibility for accommodation of space requirements1
The Novus Micro Secure provides constant, reliable backup power for small critical load applications such as security cameras, surveillance systems, WiFi equipment and outdoor lighting. With its NEMA 3R enclosure, this easy-to-install solution includes a UPS power module and battery bank for an all-in-one out-of-the box solution: just wire the inputs, your load and communications (if ordered), and it’s ready for operation. Due to its compact design and light weight, the Micro Secure can be wall or pole mounted (when using the optional pole mounting bracket). The Micro Secure can also be used as a power supply for security camera applications. An optional Ethernet/SNMP interface is available.
1 Mounting brackets sold separately
Agency Compliance
Electrical safety: UL1778, CSA 22.2 No. 107.1
Marks: CCSAUS , CE* EMI: Class A FCC/CISPR, EN50091-1-2, EN60950 *CE applies to 230VAC version only
Alpha Novus Micro Secure 100
Outdoor SolutionsNovus Micro Secure 100
6
Out
do
or
So
luti
ons
Alpha AC Catalogue 2008 For Prin6 6 7/30/2008 3:02:19 PM
Clean, uninterruptible backup power ensures your system will remain up and running during power outages
Wide range Automatic Voltage Regulation without going to batteries extends battery life, even during periods of surge or sag in voltage from utility power
External communications via RS-232 port or (optional) Ethernet SNMP interface provides local or remote monitoring control
Independently programmable control and report relays allow tracking and controlling of key functions1
User-friendly LCD display allows "at-a-glance" monitoring and troubleshooting2
Event and alarm logging with time and date stamping simplifies and accelerates troubleshooting
A wide operating temperature range of -40º to 74ºC (-40º to 165ºF)3 is suitable for most extreme operating environments
Temperature compensated battery charging protects batteries from over charging at extreme temperatures
The Alpha Novus Micro line provides constant reliable backup power in 300VA or 1000VA models for use in Access Control, Security, Parking, Public Utility and Telecommunications applications. This all-in-one solution is comprised of a NEMA 3R outdoor rated enclosure, an uninterruptible power supply module and battery bank. Batteries selection is based on the application and run time requirements. Be sure to order the appropriate battery connector kit for your specific application. The Novus Micro can withstand harsh outdoor conditions operating in temperatures of -40°C to 74°C (-40°F to 165°F) to support your mission critical applications with clean, uninterruptible power. Optional Battery Heater Mats provide heat to the batteries and are recommended for optimal performance in cold climates. For extended run time applications, the XL or XL3 provide space to accommodate additional batteries.
Nominal Specifications
Power Module: Novus Micro 300 Novus Micro 1000
North America International North America International
Battery String Voltage 24VDC 24VDC 48VDC 48VDC
Nominal Voltage 120 VAC 230VAC 120VAC 230VAC
Nominal Frequency 60Hz 50Hz 60Hz 50Hz
Input Current 5.4A 2.8A 14A 7.3A
Input Voltage Range 85-175VAC 150- 328VAC 85-175VAC 150- 328VAC
Output Current 2.5A 1.3A 8.3A 4.3A
Output Voltage Regulation +/- 10% over input voltage range
Output Power @50°C 300W/VA 300W/VA 1000W/VA 1000W/VA
Run Time* 2 x 50Ah batteries - 2 hrs 12 mins 4 x 18Ah batteries - 26 mins
* Run time on battery power can vary based on loads, temperature and battery. Other battery options are available.
Dimensions (W x H x D) Novus Micro 14.1” x 19.7” x 11.6” 358 x 500 x 294 mm
Novus Micro XL 14.1” x 30.6” x 11.6” 358 x 776 x 294 mm
Novus Micro XL3 14.1” x 52.4” x 11.6” 358 x 1330 x 294 mm
Weight (without batteries) 43.4 lb / 19.7 kg 49.8 lb / 19.7 kg 69.2 lb / 22.6 kg
Agency Compliance
Electrical safety: UL1778, CSA 22.2 No. 107.3,
EN50091-1-2, EN60950
EMI: Level A FCC, CISPR22, EN55022
Marks: CCSAUS , CE* *CE applies to 230VAC version only
Novus Micro Novus Micro XL Novus Micro XL3
Alpha Novus Micro 1000
1 This feature is available on the Novus Micro 300 model only2 This feature is optional for the Novus Micro 300 model3 This applies to the UPS module only. Batteries may require a heater mat at lower temperatures. Output power derates after 50ºC
Outdoor SolutionsAlpha Novus Micro, Micro XL, Micro XL3
7
Outd
oo
r So
lutions
Alpha AC Catalogue 2008 For Prin7 7 7/30/2008 3:02:23 PM
Alpha offers a range of transfer and bypass switches as part of its total power solutions package. These switches allow for power to be seamlessly migrated between utility line to battery backup or generator.
Alpha Automatic Transfer Switch
120V/30A 230V/16A Alpha’s Automatic Transfer Switch acts as a fail-safe device by switching the critical load to the utility line should a fault occur in the UPS. The ATS ensures that clean power is always provided to the critical load, ensuring that your mission-critical equipment always remains running in the event of an outage. This transfer switch also includes a standard manual bypass switch which eliminates costly equipment downtime while servicing the UPS or replacing the batteries.
Alpha Automatic Generator Transfer Switch
120V/30A 230V/16A Alpha’s Automatic Generator Transfer Switch automatically transfers the input to the UPS from the utility line to a portable AC generator. The GTS allows the generator to recharge the batteries and ensure your applications remain in operation during extended power outages. For manually connecting or disconnecting a generator, a standard switch is included.
Alpha Maintenance Bypass Switch
120V 230V Option not available Alpha’s Maintenance Bypass Switch allows the user to manually bypass the UPS system for service or routine maintenance.
Other Mounting Options
Wall mount kit – Part number 740-756-21 Rack mount kit – Part number 593-364-P4
Automatic Transfer Switch
Automatic Generator Transfer Switch
Alpha Maintenance Bypass Switch
Mounting Options
Outdoor SolutionsTransfer and Bypass Switches
8
Out
do
or
So
luti
ons
Alpha AC Catalogue 2008 For Prin8 8 7/30/2008 3:02:35 PM
Batteries & AccessoriesAlpha offers a comprehensive line of AlphaCellTM batteries in a number of sizes and technologies to support your outdoor applications. Included in our battery line are AGM and Gel batteries that offer extended runtime and warranty configurations. Our Gel Cell batteries last longer and are more reliable because of their excellent heat displacement characteristics. Independently tested, AlphaCellTM GXL batteries come with a full replacement non-prorated warranty. These batteries have seven to eight years of expected life and trouble free performance offering reduced maintenance costs. Our AGM batteries are also available to support a variety of applications. Both models are ready with 100% out of the box capacity.
In addition to our battery offerings, Alpha also has accessories to complement your battery installation or support your battery testing needs.
Alpha AC Catalogue 2008 For Prin9 9 7/30/2008 3:02:35 PM
Valve Regulated Lead Acid (sealed) batteries
Designed for indoor, outdoor standby applications
100% out-of-box runtime capacity
Maintenance-free threaded inserts
100% replacement warranty
Alpha offers a wide selection of sealed VRLA-AGM and VRLA-Gel batteries to provide power to a number of applications. Gel batteries provide good thermal dissipation to help ensure the best performance for you application. Alpha’s standby battery offering includes six different models incorporating four unique battery technologies, ensuring optimal performance for all outdoor powering applications. These batteries provide improved performance, longer runtimes and extended service life.
BatteriesAlphaCellTM Gold & GXL
10
Bat
teri
es a
nd A
cces
sori
es
AlphaCell™ Gold & GXL
Alpha AC Catalogue 2008 For Prin10 10 7/30/2008 3:02:41 PM
General Specifications
Model 215 GOLD-HP 190 GOLD-HP 210 GXL 180 GXL 165 GXL 85 GXL-HP
Heat resistance Extreme Extreme High High High Extreme
TerminalsThreaded insert 1/4” - 20 UNC
Threaded insert 1/4” - 20 UNC
Threaded Insert 1/4” - 20 UNC
Threaded Insert 1/4” - 20 UNC
Threaded Insert 10-32 UNF
Typical Runtime (minutes) 215 190 210 180 165 85
Cells Per Unit 6 6 6 6 6 6
Voltage Per Unit 12.8 12.8 12.8 12.8 12.8 12.8
Conductance Value 1175 1100 1175 1100 1000 600
Max. Discharge Current (A) 900 900 900 900 800 600
Short Circuit Current (A) 2800 2600 2800 2600 2500 2200
10 Second Volts @ 100A 11.4 11.3 11.4 11.3 11.2 10.8
Impedance @ 60Hz (Ohms) 0.005 0.005 0.005 0.005 0.0055 0.0065
Capacity at 20hrs (to 1.75VPC) 107Ah 95Ah 106Ah 94Ah 86Ah 50Ah
BCI Group Size 31 31 31 31 27 22
Mechanical Specifications
Weight (lb/kg) 72/32.7 66/30 72/32.7 66/30 63/28.6 39.6/18
Height w/ Terminals (in/mm) 8.48/215.4 8.48/215.4 8.48/215.4 8.48/215.4 9.05/229.8 8.09/205.6
Width (in/mm)* 13.42/340.9 13.42/340.09 13.42/340.09 13.42/340.09 12.5/317.8 8.99/228.3
Depth (in/mm)* 6.80/172.7 6.80/172.7 6.80/172.7 6.80/172.7 6.83/173.4 5.47/138.9
Operating Temperature Range
Discharge-40 to 71°C (-40 to 160°F)
-40 to 71°C (-40 to 160°F)
-40 to 71°C (-40 to 160°F)
-40 to 71°C (-40 to 160°F)
-40 to 71°C (-40 to 160°F)
-40 to 71°C (-40 to 160°F)
Charge (with temp compensation)
-23 to 60°C (-9.4 to 140°F)
-23 to 60°C (-9.4 to 140°F)
-23 to 60°C (-9.4 to 140°F)
-23 to 60°C (-9.4 to 140°F)
-23 to 60°C (-9.4 to 140°F)
-23 to 60°C (-9.4 to 140°F)
Float Charging Voltage (VDC) 13.5 to 13.8 13.5 to 13.8 13.5 to 13.8VDC 13.5 to 13.8VDC 13.5 to 13.8VDC 13.5 to 13.8VDC
AC Ripple Charger 0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4% P-P
*: Dimensions at top of battery For information on the warranties please contact your sales rep.
Current Discharge Ratings Table in Amps (end Voltage 1.75VPC)
Hours 1 2 3 4 6 8 10 12 20 24 48 72 100
215 Gold 67.8 40.5 29.1 22.9 16.1 12.6 10.2 8.7 5.46 4.61 Call Call Call
210 GXL 66.3 39.6 28.5 22.4 15.8 12.3 10 8.54 5.34 4.51 Call Call Call
190 Gold 64.5 37.1 26.6 20.8 14.6 11.4 9.4 7.9 4.96 4.2 2.2 1.5 1.08
180 GXL 61.2 35.2 25.2 19.7 13.9 10.8 8.9 7.5 4.7 4 2.1 1.4 1.03
85 GXL-HP 33.2 18.8 13.3 10.4 7.34 5.7 4.68 3.97 2.5 2.12 1.11 0.76 0.56
165 GXL 55.9 32.8 23.5 18.4 12.9 10.0 8.2 6.9 4.3 3.7 1.9 1.29 0.94
BatteriesAlphaCellTM Gold & GXL
11
Batteries and
Accesso
ries
Alpha AC Catalogue 2008 For Prin11 11 7/30/2008 3:02:42 PM
Specifications
Model: 135 AGM-P 160 AGM
Silver Alloy: AGM-P N/A
CA/SN Alloy: N/A N/A
Typical Runtime (minutes)2: 135 160
Cells Per Unit: 6 6
Voltage Per Unit: 12.8 12.8
Conductance Value: 1125 1300
Max. Discharge Current (A): 800 800
Short Circuit Current (A): 3100 3300
10 Second Volts @ 100A: 11.5 11.6
Ohms Impedance 60Hz: 0.005 0.004
Capacity at 20hrs: (to 1.75VPC) 75Ah 88Ah
BCI Group size: 24 27
Weight (lb/kg): 54.8/24.9 62/28
Height w/ terminals (in/mm): 8.02/203.6 9.05/229.8
Width (in/mm)4: 10.26/260.5 12.57/317.8
Depth (in/mm)4: 6.83/173.4 6.83/173.4
Operating Temperature Range
Discharge: -40 to 71˚C -40 to 71˚C
(-40 to 160˚F) (-40 to 160˚F)
Charge (with temp compensation): -23 to 60˚C -23 to 60˚C
(-9.4 to 140˚F) (-9.4 to 140˚F)
Float Charging Voltage (VDC): 13.5 to 13.8 13.5 to 13.8
AC Ripple Charger:0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4%
1 Warranty varies by country and region. Consult your sales person for details.2 Runtimes calculated using a 25A DC constant current load with voltage discharge to 1.75V/cell @ 25˚C.3 L-Type: applies to 210/180/165 GXL and AGM models. Copper Alloy 10-32 Insert: applies to 85 GXL only. Copper Alloy 1/4" insert applies to 135 GXL only.4 Dimensions at top of battery.
BatteriesAlphaCell™ AGM
Designed for indoor, outdoor standby applications
100% out-of-box runtime capacity
Maintenance-free threaded inserts
100% replacement warranty
Convenient carrying handle standard on all models
12
Bat
teri
es a
nd A
cces
sori
es
AlphaCell™ AGM
Alpha AC Catalogue 2008 For Prin12 12 7/30/2008 3:02:44 PM
BatteriesAlphaCell™ FT
Front terminals with protective covers
Valve regulated lead acid batteries
Long life gel batteries can be used outdoors
Ideal for telecom and cable applications
Alpha enhances its AlphaCellTM battery family to include the sealed FT series of front terminal batteries for cable television and telecommunication applications. The AlphaCellTM FT series are designed for long life. Benefits of these new batteries include: central gassing system, hinged front covers, integral flame arrestor, recyclable lead and plastics and low self-discharge rates. These batteries come with a handle for carrying convenience.
General Specifications
Model 195 GXL-FT 225 AGM-FK
Service Life Extended Extended
Sealed VRLA Valve Regulated Lead acid Valve Regulated Lead acid
Heat resistant High Moderate
Hydrogen Emission Low Low
Terminals 16mm Insert M6 thread 16mm Insert M6 thread
Typical Runtime (minutes) 195 225
Cells Per Unit 6 6
Voltage Per Unit 12.8 12.8
Conductance Value 1200 1400
Max. Discharge Current (A) 400 400
Short Circuit Current (A) 3000 3100
10 Second Volts @ 100A 10.8 11.2
Impedance @ 60Hz (Ohms) 0.0041 0.0045
Capacity at 20hrs (to 1.75VPC) 110Ah 88Ah
Mechanical Specifications
Weight (lb/kg) 76.29/34.52 75.14/34
Height w/ Terminals (in/mm) 11.22/285 11.22/285
Width (in/mm)* 4.33/110 4.33/110
Depth (in/mm)* 15.55/395 15.55/395
Operating Temperature Range
Discharge -40 to 71°C (-40 to 160°F) -40 to 71°C (-40 to 160°F)
Charge (with temp compensation) -20 to 50°C (-4 to 122°F) -20 to 50°C (-4 to 122°F)
Float Charging Voltage (VDC)Float 2.27 to 2.30VPC @25°C cycling 2.35VPC@25°C
Float 2.27 to 2.30VPC @25°C cycling 2.35VPC@25°C
AC Ripple Charger 0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4% P-P
*: Dimensions at top of battery For information on the warranties please contact your sales rep.
Current Discharge Ratings Table in Amps (end Voltage 1.75VPC)
Hours 1 2 3 4 6 8 10 12 20 24 48 72 100
195 GXL-FT 71.1 38.0 26.8 21.1 15.2 12.0 9.92 8.48 5.50 4.60 2.31 1.56 1.13
225 AGM-FT 81.00 43.10 30.30 23.70 16.70 12.90 10.40 8.90 5.70 4.80 2.43 1.62 1.18
13
Batteries and
Accesso
ries
AlphaCell™ FT
Alpha AC Catalogue 2008 For Prin13 13 7/30/2008 3:02:45 PM
BatteriesAlphaCell™ SMU-HR
High Rate Discharge VRLA Battery
Power range available in 12V with capacities from 9 to 135Ah
Optimized grid for high power density
Upright, side or end mounting
Thermally welded case to cover bond eliminates leakage
Optional flame retardant ABS casing to UL94-VO
100% replacement warranty
The AlphaCell™ SMU-HR, with Absorbed Glass Mat (AGM) technology, is a high discharge rate VRLA battery specifically designed for uninterruptible power supplies, power generation, and switchgear applications. Low calcium grid alloy reduces gassing to extend battery life. This high rate discharge cycle battery is available in 12V with capacities from 9 to 135Ah.
General Specifications
Type Valve Regulated Lead Acid
Range of Capacity 9 to 35Ah
Recommended Float Voltage 13.5VPC @ 20°C (68°F)
Operating Temperature Nominal 25°C (77°F) NOTE: can operate at higher temperature up to 74°C (165°F) but degrades life of battery
Terminal Type Threaded Copper Insert
Optional UL 94 VO Flame Retardants Casing
For information on warranties please contact your sales rep.
14
Bat
teri
es a
nd A
cces
sori
es
AlphaCell™ SMU-HR
Alpha AC Catalogue 2008 For Prin14 14 7/30/2008 3:02:47 PM
Battery Heater Mats
Low temperatures can compromise battery performance by reducing runtimes and slowing down the recharge rate. Battery Heater Mats combat these negative effects for better battery performance in cold conditions. In extreme environments, battery damage can result if battery heater mats are not used.Thermostat Specifications:Turns on when temperature falls below 5°C/41°F Turns off when temperature rises above 15°C/59°F
AlphaGuard™ Battery Charge Management System
AG-CMT-4 AlphaGuard™ Charge Management SC, 48V String – including Battery interface cable
The AlphaGuard is a battery charge management system that monitors and protects your batteries for runtime optimization and longer battery life. CSA and UL approved, AlphaGuard allows you to replace single batteries rather than the whole string. It spreads charge voltage equally across batteries to maximize battery life and compensates for battery differences as they age.Also available: AlphaGuard Potted Version for Below Grade Applications. The potted version is ideal for applications where batteries are installed under ground or subject to damp conditions or possible immersion.
Note: For some applications Alpha offers an extended battery warranty when AlphaGuard is used. Contact your Alpha representative for complete details.
Battery Testing Equipment
Alpha’s battery testing equipment provides accurate information about the status of installed standby batteries allowing you to budget for early detection of failed or degraded batteries and for replacements with confidence.A fast, reliable and affordable testing process. Conductance testing is coupled with a simple utility load test – arms the operator with the quality of data necessary to know the status of installed standby batteries, allowing for detection and replacement before failure occurs and puts backup during an outage at risk.
AlphaGuard™ Battery Charge Management System
Battery Heater Mats
Celltron Essential Battery Testing Equipment
AlphaGuard™ Potted version
Battery Accessories
15
Batteries and
Accesso
ries
Alpha AC Catalogue 2008 For Prin15 15 7/30/2008 3:02:52 PM
Alpha AC Catalogue 2008 For Prin16 16 7/30/2008 3:02:52 PM
GeneratorsAlpha offers portable and stationary DC generators for extra long back up power runtimes. Completely enclosed and water resistant for safe operation in the field, the AlphaGen™ is quiet, convenient, and extremely economical. Its oversized metal gas tank can provide extended runtimes of up to 20 hours.
Alpha AC Catalogue 2008 For Prin17 17 7/30/2008 3:02:52 PM
Accessories
30’ Output Interface 10’ P/N 875-324-22 30’ P/N 875-324-20 50’ P/N 875-324-21
Ring Lug Battery Interface
P/N 874-946-21
Alligator Clamp Battery Interface P/N 874-946-20
Y-Adaptor Battery P/N 874-946-22
DCX 3000 (front view) DCX 3000 with optional Wheel Kit and Locking Handle
GeneratorsAlphaGenTM DCX 3000
Part Number: 041-028-10
Engine:Honda GX 200 6.5hp, Air-cooled, OHV, Single cylinder, Manual recoil starting, Manual choke
Rated Power: 2800W continuous, 3000W max.
Alternator:Permanent Magnet, brushless, bearingless
Dual range selector
36V:39.5Vdc nominal at generator output connector
48V:52.5Vdc nominal at generator output connector
Output Regulation: 1Vdc
Control Features:Automatic Voltage Regulation Electronic Governor Over current Protection Analog voltmeter with back light
Cable Interface: Anderson type SBE-80 connector
Fuel Tank: 3.4 gallon metal tank with level gauge
Runtime
@ 25% Load: 20 hrs
@ 80% Load: 10 hrs
@ 100% Load: 7.2 hrs
Noise: Approx. 58dBA @ 7m under full load
Frame: Fully Enclosed
Dry Weight: Less than 118lb (53.5kg)
Dimensions (in/mm):22.4H x 18.9W x 25.8D / 569H x 480W x 655D
Agency:CSA C22.2 No. 100-95, 107.1-01, 107.2-M89, 0.4 FCC part 15B Class A
Required Accessories
Output Interface Cable: Available in 10’, 30’ or 50’ lengths
Battery Interface Cable:Choose Ring Lung, Heavy-Duty Alligator Clamp, or Y-adapter*
* Connects the power supply’s battery input directly to the generator
General Specifications
DCX 3000
18
Gen
erat
ors
Portable DC technology generator
Automatic Transfer Switch (ATS) not required
No need to disconnect or reconnect power supply to utility power
Selectable output for 36 or 48VDC operation up to 3000W
Super quiet operation only 58dBA @ 7m/22ft
Alpha expands its generator line to include a portable 3.0kW DC gasoline generator. The compact, lightweight AlphaGen generator is designed specifically for powering cable television, telecommunications, broadband and traffic applications that do not have integrated generators as a primary component of the power system.
The portable generator incorporates several technological advantages including: 36 or 48V selectable dual voltage output based on Permanent Magnet Generator (PMG) technology, 3000W of power, and oversized fuel tank for up to 20hrs of runtime at 25% load or 7.2hrs at 100% load.
Additional features include a convenient front panel with a keyed on/off switch, output connector, output indicators, voltmeter, fuel valve and engine choke.
Alpha AC Catalogue 2008 For Prin18 18 7/30/2008 3:03:02 PM
All Models Configuration Options:
Gas Inlet Pressure:0.5 to 2 PSI Inlet Pressure (Contact Alpha Engineering for additional supply resources)
Ign Charger Voltage: 13.5VdcIgn Charger Current: 6A max.
Remote Interface Length:75ft typical. Distance depends upon installation, de-rating and wire gauge.
Agency Compliance:UL1778, UL2200, NFPA 37/54/58 and 70, CSA C22.2 No.107.1, EMC/FCC Part 15 Class A
Fuel System, Controls
& Monitoring:
The controls and fuel system meet applicable sections of NFPA 37, 54 and 58 for automatic unattended operation of remotely located generators. Full System Control and Status Monitoring included.
Sensors: Gas Hazard, Pad Shear, Water Intrusion & Tamper
Safety Shutdowns:
• Low Oil Pressure • Over Temp • Low Fuel Pressure Shutdown (Propane only) • Water Intrusion • Pad Shear • Gas Hazard (Propane or Natural Gas) • Over-Speed • Over-Crank
Optional Feature:Cold Start Kit: Provides additional starting capability at temperatures below -18°C / 0°F.
Optional Accessories
DCX-PG-WK: Portable Generator Wheel Kit (P/N 745-793-20)
DCX-PG-HANDLE: Locking Handle (P/N 745-792-20)
AG-PG-TOOL: Punch Tool Kit For Enclosures (P/N 745-131-20)
AG-PG-UK: Enclosure Upgrade Kit (P/n 745-131-21)
AG-CAB-KIT:Cable Bag With Cable And Key Lanyard (P/N 745-764-21-001)
Output Rating: 3.5kW 5.0kW 7.5kW
DC Output Voltage: 39.0V ±0.5V @ no load 36V config 39.0V ±0.5V @ no load 36V config 52.0V ±0.5V @ no load 48V config52.0V ±0.5V @ no load 48V config 52.0V ±0.5V @ no load 48V config 104.0V ±0.5V @ no load 96V config
DC Output Load Regulation:
0.5V 0.5V 0.5V
Output Current:39.0V @ 90A max. / 52.0V @ 67A max.
39.0V @ 128A max. / 52.0V @ 96A max.
52.0V @ 144A max. / 104V @ 72A max.
Engine: 398cc, Air cooled, Single OHV 10.5hp (using natural gas fuel)RPM: (Variable Speed): 2800 to 3600RPM 2800 to 3600RPM 2800 to 3600RPM
Model: CE-3x2 CE-9x2 CE-3x2 CE-9x2 PN-6x
Height (in/cm): 44/111.2 52/132.1 44/111.2 52/132.1 39/99 (57/144 with optional pedestal)Width (in/cm): 26/66 52/132.1 26/66 52/132.1 39.25/100Depth (in/cm): 24/61 24/61 24/61 24/61 24/61Weight (lb/kg): 383/174 413/187 383/174 413/187 338/174 (370/168 with optional pedestal)
CE-3XL
Generators AlphaGen™ Curbside
CE-3x2 3.5 or 5kW CE-9x2 3.5 or 5kW
CE-3/9G Propane Storage for Generator
(For 3.5 and 5kW)
PN-6x 7.5kW (PN-6x is not compatible with CE-3/9G)
General Specifications
19
Generato
rs
Cost effective extended runtime solution
Quiet operation, small size, and low profile
Designed for stand-alone or collocated applications
Meets UL2200, NFPA 37, 54, 58 & 70 standards
The AlphaGen Curbside generator system incorporates industry leading power technology to provide a stand-along power solution for curbside or remote applications. The Curbside line offers natural gas or propane powered generators, exclusive audible noise baffling, remote status monitoring features, and durable weather resistant enclosures. An optional cold start kit for extreme cold temperature is available as are enclosures for propane storage.
Alpha AC Catalogue 2008 For Prin19 19 7/30/2008 3:03:09 PM
Alpha AC Catalogue 2008 For Prin20 20 7/30/2008 3:03:09 PM
EnclosuresAlpha’s hardened outdoor enclosures protect power modules, batteries, and components from harsh environmental conditions and unauthorized access. Our enclosures come in a variety of configurations including side mount, ground mount, or pole mount designs. Alpha can also custom design and manufacture enclosures with specific features for unique applications.
Alpha AC Catalogue 2008 For Prin21 21 7/30/2008 3:03:09 PM
EnclosuresAlpha Outdoor Enclosure Side Mount 6
Alpha Outdoor Enclosure Side Mount 6
Stand Alone or Side Mount enclosure
Can be installed on any existing ground/pad mount enclosure
Engineered to minimize temperature differential between batteries
Powder coat finish provides excellent corrosion protection
Available in clear coat, sea foam green, pine green and gray
Alpha’s Flextra Special Purpose side mount outdoor rated enclosures provide secure and cost effective method of adding standby capacity to any installed ground/pad mount enclosure. For optimum battery life, Flextra Side Mount enclosures have been engineered to minimize the temperature differential between batteries located within the existing enclosure and batteries in the side mount enclosure.
The Flextra B4 can be mounted on either the right or the left side of the existing enclosure and has room for 4 x 210Ah AlphaCell™ Batteries. The Flextra B4 kit includes the enclosure and door, key set, and all necessary mounting hardware and installation instructions.
Dimensions (in/mm): 19.5W x 48H x 8.75D/495W x 219H x 222W
22
Enc
losu
res
Alpha AC Catalogue 2008 For Prin22 22 7/30/2008 3:03:17 PM
EnclosuresAlpha B4
Side Mount enclosure
Can be installed on any existing ground/pad mount enclosure
Engineered to minimize temperature differential between batteries
Powder coat finish provides excellent corrosion protection
Available in clear coat, sea foam green, pine green and gray
Alpha’s B4 side mount outdoor rated enclosure provide secure and cost effective method of adding standby capacity to any installed ground/pad mount enclosure. For optimum battery life, the Side Mount enclosure has been engineered to minimize the temperature differential between batteries located within the existing enclosure and batteries in the side mount enclosure.
The B4 can be mounted on either the right or the left side of the existing enclosure and has room for 4 x 210Ah AlphaCell™ Batteries. The B4 kit includes the enclosure and door, key set, and all necessary mounting hardware and installation instructions.
Dimensions (in/mm): 19.5W x 48H x 8.75D/495W x 219H x 222W
B4
23
Enclo
sures
Alpha AC Catalogue 2008 For Prin23 23 7/30/2008 3:03:18 PM
EnclosuresFlextra P Series
Universal Mount enclosure
Aluminum welded construction
Pole mounting brackets included
Removable, lockable doors and easy open lids
Durable, powder coat finish
Slide trays for batteries
The P Series is a single power supply enclosure supporting distributed power architectures and used for pole or wall mount installations. The power supply is positioned in a compartment separate from and above the batteries to maximize convection cooling. Ideal for use in all climates, each enclosure includes a high magnetic circuit breaker, studs to mount optional Maintenance Bypass Switch and a cooling fan.
P6 P8
P4
Flextra Universal Mount Enclosures Extended Standby
P4 P6 P8
Dimensions (in/mm): 30.25W x 24.75H x 16.0D 768W x 629H x 406D
24.25W x 36.75H x 14.0D 615W x 933H x 355D
30.25W x 36.88H x 16.0D 768W x 937H x 406D
Weight (lb/kg) 57/26 68/31 121/55
Battery Capacity 4 6 8
Pole Mount Bracket
Powder Coat Finish
All Aluminum Const.
Removable Door/Lid
Door Prop Rod
Battery Slide Tray 1 2 2
120V 20A or 240V 15A Breaker
Duplex/Quad AC
Local Remote Indicator Light
Enclosure Cooling Fan
Storm Hood
Battery Heater Mat
Internal Service Entrance
Breaker Box
Factory Installed Breaker Box
LA-P+
Standard Features Available Options
Note: Color options available. *P6 is only pole or wall mountable
24
Enc
losu
res
Alpha AC Catalogue 2008 For Prin24 24 7/30/2008 3:03:20 PM
EnclosuresFlextra U Series
Ground/Pad Mount enclosure
Aluminum welded construction
Removable, lockable doors and easy open lids
Durable, powder coat finish
Slide trays for batteries
The U Series is a single power supply enclosure supporting distributed power architectures and used for ground or pad mount installations. The power supply is positioned in a compartment separate from and above the batteries to maximize convection cooling. Ideal for use in all climates, each enclosure includes a high magnetic circuit breaker, studs to mount optional Maintenance Bypass Switch and a cooling fan.
U6 U8
U4
Flextra Ground/Pad Mount Enclosures
U4 U6 U8
Dimensions (in/mm): 30.25W x 24.75H x 16.0D 768W x 629H x 406D
24.25W x 36.75H x 14.0D 615W x 933H x 355D
30.25W x 36.88H x 16.0D 768W x 937H x 406D
Weight (lb/kg) 57/26 68/31 121/55
Battery Capacity 4 6 8
Powder Coat Finish
All Aluminum Const.
Removable Door/Lid
Battery Slide Tray 1 2 2
120V 20A or 240V 15A Breaker
Duplex/Quad AC Recept.
Local Remote Indicator Light
Enclosure Cooling Fan
Battery Heater Mat
LA-P+
AC Output Indicator Light
Pedestal Extension
External Meter Base
Internal Breaker Box
External Breaker Box
Security Bar Kit
Standard Features Available Options
25
Enclo
sures
Alpha AC Catalogue 2008 For Prin25 25 7/30/2008 3:03:24 PM
EnclosuresFlextra Z Series
Extreme conditions enclosure
Meets Telcordia Seismic Zone-4 standard
NEMA 3R outdoor rated enclosure
Simple, flexible options for pole, wall, ground or pedestal installations
Wide temperature range -40˚C to +50˚C
Alpha’s Flextra Extreme enclosures provide protection to outdoor UPS systems used in extreme climates. Four and eight battery configurations are available and an optional generator can be used for extended runtimes. Flexible power, runtime and voltage configurations make the Flextra Extreme the best choice for powering outdoor applications around the world. An optional maintenance bypass feature allows for easy and efficient battery and UPS replacement.
Standard FeaturesInput/Output Surge ProtectionIntelligent buck/boost operation for greater protectionHot swappable UPS and batteriesNoise suppression, FCC Class BMultiple mounting configurations Rugged, outdoor weather resistant constructionLockable enclosureNRTL/CSA/CE approved
8 Battery System also includes: Telcordia Zone 4 approved with Battery Retention Bar Telcordia salt fog tested, 14 day operational Telcordia approved Door Restraint
Enclosure SpecificationsDimensions 4 Battery 8 Battery
Width (in/mm): 24/610 31/788Height (in/mm): 36/914 37/956Depth (in/mm): 14/56 16/407Weight (lb/kg)**: 350/158 812/368Finish: Powder coat white over aluminum
* Backup time depends on load, battery, and operating temperature. Optional DC Generator provides up to 100hrs backup.** Weight dependent upon internal battery choice.
Note: The W8 enclosure is resistant to the harshest weather conditions.
26
Enc
losu
res
Flextra Z
Alpha AC Catalogue 2008 For Prin26 26 7/30/2008 3:03:26 PM
EnclosuresFlextra Node
Ground/Pad Mount node
Rugged outdoor enclosure available in 3.0 and 5.0kVA configurations
Incorporates Alpha CFR power module, Alpha bypass switch and batteries
Provides complete input to output isolation with superior surge and lightning protection
Additional battery and generators cabinets available
Alpha’s Flextra Node Ground/Pad Mount Enclosures provide superior backup power protection for outdoor mission critical applications. Designed to meet or exceed the safety standards established by UL, CSA, CE and VDE, the enclosures set the standard for effective outdoor powering. The input power factor correction brings low power-factor loads to near unity, reducing electric utility costs. Fully compatible with AlphaGenTM Curbside, Alpha’s outdoor line of natural gas or propane generators, to provide longer runtimes.
Enclosure Configurations
N3
1 power module 1 bypass switch 1 battery string
Dual N3
1 power module 1 bypass switch 4 battery strings
N3
Options:
Battery Heater Mat (BHM)
Manual Transfer Switch (MTS)
Meter Head
Standby Generator
Propane Storage Cabinet
Remote Generator Interface Kit
27
Enclo
sures
Alpha AC Catalogue 2008 For Prin27 27 7/30/2008 3:03:29 PM
Integrated Telecom grade environmentally controlled UPS system
Front and rear accessible 19’” or 23” equipment racks
46 RMU capacity
High capacity AC or DC air conditioner options
Field replaceable fans
NEMA 3R and 4X configurations available
Agency certified
As advanced voice, video and data fiber based services are deployed deeper into the broadband network, the need for reliable, attractive, modular transition nodes increases. The Radium MiniBay supports a wide range of applications including bulk power to CATV hub and secondary hub requirements. Also ideal for remote optical transition applications including optical amplification, downstream DWDM demultiplexing, narrowcast combining and return path aggregation providing services to remote communities.
The MiniBay reduces operational costs by locating the electronics where needed and avoids the recurring costs of maintaining a real-estate intensive building. Alpha’s field power services group provides turnkey installations, turn-up and test services.
Environmental Rating:
NEMA 3R when configured with door mounted fans and filter system. NEMA 4X when configured with heat exchanger or air conditioning system.
Seismic Rating:Consult factory. A seismic rating is based on a set system configuration with defined mounting locations and equipment types.
Design Standards:Following NEC & Telcordia Technologies (Bellcore) GR-487, GR-63 and GR-108 guidelines.
Compliance:Third party approval from National Recognized Testing laboratory (NRTL).
Material: High strength corrosion resistant aluminumFinish: Almond color powdercoat finish
Weight & Dimensions
Weight (lb/kg) Dimensions (in/cm):
Equipment Enclosure:
195/88.532D x 44H x 30W / 81.3D x 106.7H x 76.2W
Battery Storage Module:
130/5932D x 14H x 30W / 81.3D x 35.6H x 76.2W
Riser Module: 102/46.332D x 14H x 30W / 81.3D x 35.6H x 76.2W
Side Chamber SC1:
100/45.412D x 72H x 32W / 30.5D x 81.3H x 131.1W
Side Chamber SC2:
89/40.412D x 72H x 32W / 30.5D x 81.3H x 131.1W
Fans and Filters
The most basic thermal management system supporting the MiniBay utilizes conformal-coated, variable speed and alarm monitored fans with electrostatic air filters providing up to 500W thermal dissipation. This configuration has a NEMA 3R rating.
Variable speed controlled DC fans continue to operate during a utility outage
Conformal-coated fans
Electrostatic and washable air filters
Field replaceable fans
Heat Exchanger An airtight rear door and a heat exchanger equipped hinged front door providing over 500W thermal dissipation. With a 500W load, the internal ambient temperature will not exceed 15 to 27°F above external ambient. With a 250W load, the internal ambient temperature will not exceed 7°C or 12.6°F above external ambient. This configuration has a NEMA 4X rating.
Heat exchanger heat pipe technology provides efficient thermal transfer
Minimizes internal temperature rise above external ambient
Variable speed controlled DC fans continue to operate during a utility outage
Field replaceable fansDC Air Conditioner
For applications requiring the most reliable below ambient cooling and dehumidifying system for supporting seamless performance through extended utility outages. Cooling capacity 878W dissipated at 43°C outdoor ambient allowing a Maximum* internal ambient of 40°C / 104°F.
Variable speed brushless motor 24/48Vdc compressor system assures optimum efficiency over the full range of thermal loading and ambient temperatures
3,000BTU @ 43°C/110°F rating
Redundant conformal-coated fans have >50,000hrs of life and low voltage disconnect circuitry
AC Air Conditioner
Ideal for applications requiring cooling and dehumidifying with little or no standby runtime performance. Cooling capacity 1464W dissipated at 43°C outdoor ambient allowing a Maximum* internal ambient of 40°C / 104°F.
5,000BTU @ 43°C/110°F rating
Washable electrostatic filters
240Vac* Reducing the internal dissipated heat load reduces internal ambient.
EnclosuresRadium MiniBay
Specifications
MiniBay with Fiber Management
28
Enc
losu
res
Radium MiniBay
Alpha AC Catalogue 2008 For Prin28 28 7/30/2008 3:03:31 PM
Indoor SolutionsAlpha Technologies offers three lines of single phase indoor Uninterruptible Power Supplies (UPS), providing customers with a range of standard and optional features to meet their specific UPS needs. This includes entry level line interactive models, full featured double conversion products and controlled ferroresonant designs for the most robust applications. All lines are offered in tower and rack mount configurations. An additional indoor UPS family, part of our controlled ferroresonant line is designed specifically for medical and healthcare applications.
We also offer three phase indoor UPS solutions.
Alpha AC Catalogue 2008 For Prin29 29 7/30/2008 3:03:31 PM
Diagrams below will help you understand the different topologies used in our indoor UPS products.
Line InteractiveIn normal operation, when AC line voltage is present, power is filtered for voltage spikes and output voltage is regulated. Some electricity is used to keep the batteries fully charged. When the AC line voltage is lost or falls outside the input range, AC power is supplied from the batteries through the inverter.
Advantages of line-interactive topology:
• Automatic Voltage Regulation (AVR)
• Lower electricity consumption (less costly to operate) – More efficient because less power conversion is performed when acceptable AC input is present.
• Higher reliability – Lower component count and lower operating temperatures.
Double conversionIn normal operation, all incoming AC power is rectified to DC power, supplying the DC bus. The output inverter then inverts the DC power to AC power to support the critical loads. When the AC input is lost or goes out of range, the UPS draws power from its battery so that AC output is not affected. Because the AC input with it’s spikes, voltage blips and anomalies is first converted to DC, there is less need for using the battery when these AC input variances occur. Less battery usage preserves battery capacity for extended outages, and preserves battery service life.
30
Ind
oo
r S
olu
tio
ns
Indoor SolutionsUPS Topology
Alpha AC Catalogue 2008 For Prin30 30 7/30/2008 3:03:31 PM
Double conversion continuedReducing battery service life and the cost associated with it can offset the advantage of the lower initial purchase and operating costs of a line-interactive UPS thus making the overall cost similar. Situations that might call for a double-conversion on-line UPS are those that require power factor correction (PFC), small physical size, or some types of medical equipment or instrumentation.
Advantages of double-conversion topology:
• Operates less often from battery when the input voltage is highly distorted or wildly fluctuating
• Power factor correction (PFC) provided, regardless of load type
• More compact and lightweight, especially at higher power levels
Controlled Ferroresonant
The Ferro Resonant Topology is similar to a Line Interactive topology with the addition of a ferro resonant transformer to offer constant output voltage regardless of the state of the input voltage. In both normal mode and battery mode, all output is first filtered through a ferro resonant transformer isolating the output. This also provides for a seamless transfer to UPS power and offers galvanic isolation to isolate charge carrying particles from functional section of the system. Auto Voltage Regulation (AVR) is managed through Buck & Boost Mode.
Advantages of controlled ferro resonant topology:
• Best spike & surge protection with output isolation
• Zero transfer time
• Good MTBF as inverter is used in Standby mode
• Batteries are not used in a brown out condition
31
Indo
or S
olutio
ns
Indoor SolutionsUPS Topology
Alpha AC Catalogue 2008 For Prin31 31 7/30/2008 3:03:31 PM
1000 VA to 3000 VA models
Line interactive, pure sine wave technology
High speed microprocessor controlled
Advanced Automatic Voltage Regulation
Smart battery management
Hot swappable batteries
XL models for longer run times
The ALI Elite Uninterruptible Power Supply (UPS), in tower or rack mount configurations, is a microprocessor-controlled, pure sine wave, line interactive UPS featuring advanced Auto Voltage Regulation (AVR) with boost and buck. The AVR provides a wider input voltage operating range that results in fewer transfers to battery power thus extending battery life. All Alpha ALI Elite models include graphical interface, user-friendly software capable of safe unattended PC shutdown. Additional features include: smart battery management programming to optimally charge a battery based on it’s specific charging sequence, automatic frequency selection, smart communication, a robust inverter that works with a variety of external battery packs for extended run time applications, a customizable graphical user interface displaying UPS status, TCP/IP based power management and an optional Ethernet/SNMP interface. The ALI Elite is designrd to work in applications supporting servers, telecom equipment, voice and data networks or where there is a need for indoor, line interactive backup power.
Line InteractiveALI Elite
ALI Elite tower configuration
32
Ind
oo
r S
olu
tio
ns
ALI Elite rack configuration
Alpha AC Catalogue 2008 For Prin32 32 7/30/2008 3:03:34 PM
General Specifications
AC Input
Voltage: 120V nominal
Voltage Range: ±25%
Frequency: 50/60Hz ±5% (auto sensing)
AC Output
Voltage (Selectable): 100/110/120V
Frequency: 50 or 60Hz ±0.5% when on battery
Regulation: Increase of 15% if input voltage is -9 to -25% from nominal
Decrease of 15% if input is 9 to 25% from nominal
Spike Protection: 320Joules, 2ms
EMI/RFI Filtering: 10dB at 0.15MHz, 50dB at 30Mhz
Overload Capacity: 110% for 20sec, 125% for 5sec
Transfer Time: 2 to 4ms, including detection time
Waveform: Sine wave
Nominal Specifications
Model
Tower ALI Elite 1000T ALI Elite 1500T ALI Elite 2000T ALI Elite 3000T
Part Number: 017-747-110 017-747-115 017-747-120 017-747-130
Rack Mount: ALI Elite 1000RM ALI Elite 1500RM ALI Elite 2000RM ALI Elite 3000RM
Part Number: 017-747-61 017-747-65 017-747-62 017-747-63
Capacity (VA/W): 1000VA/600W 1500VA/900W 2000VA/1200W 3000VA/1800W
Input Plug: NEMA 5-15P NEMA 5-15P NEMA L5-20P NEMA L5-30P
Input Protection Fuse Fuse Breaker 20A Breaker 30A
Audible Noise: <40dBA @ 1m <40dBA @ 1m <40dBA @ 1m <40dBA @ 1m
Receptacles
Tower: 4 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-20R 4 NEMA 5-15R, 1 NEMA 5-30R
Rack Mount: 4 NEMA 5-15R 4 NEMA 5-15R 4 NEMA 5-20R 4 NEMA 5-15R, 1 NEMA 5-30R
Battery
DC Voltage: 24V 36V 48V 48V
Battery Runtimes* Tower and Rack
Runtime @ 100% Load: 3min 3min 3min 7min
Runtime @ 50% Load: 13min 13min 13min 21min
Mechanical
Tower
(in): 5.5W x 17.2D x 8.3H 6.7W x 17.7D x 8.9H 6.7W x 17.7D x 8.9H 6.7W x 22.8D x 16.9H
(mm) 140W x 436D x 210H 170W x 450D x 226H 170W x 450D x 226H 170W x 580D x 430H
Weight (lb/kg): 33.0/15 55.1/25 66.1/30 80/36
Approx. Ship Weight (lb/kg): 35.0/16 59.5/27 70.5/32 83.7/38
Rack Mount
(in): 16.9W x 15.0D x 5.1H 16.9W x 15.0D x 5.1H 16.9W x 15.0D x 5.1 16.9W x 22.1D x 7.0H
(mm): 429.3W x 381D x 130H 429.3W x 381D x 130H 429.3W x 381D x 130 429.3W x 560D x 178H
Weight (lb/kg): 44/20 57.3/26 61.7/28 75/34
Approx. Ship Weight (lb/kg): 48/22 63.4/28.8 68.5/31.1 79.3/36
*rounded to the nearest minute
Battery
Recharge Time: <5hrs to 90% recharge of internal batteries only Type: Valve Regulated Lead Acid (VRLA) No extended battery packs (available on XL models only) Interface
Front Panel Indicators: LED display–load level and battery capacity Audible Alarm: On battery–Slow beep, low battery–rapid beep, overload–continuous Communications: RS-232 with optional external SNMP
Environment
Operating Temperature: 0 to 40°C Storage Temperature: -20 to 48°C Altitude: 3500m above sea level Humidity: 0 to 95% non-condensing Safety: UL, CSA
Warranty
UPS Module and Battery:Competitive warranties included. Contact your sales representative for further details.
Line InteractiveALI Elite
33
Indo
or S
olutio
ns
Alpha AC Catalogue 2008 For Prin33 33 7/30/2008 3:03:34 PM
General Specifications
AC Input
Voltage: 120V nominalVoltage Range: ±25%Frequency: 50/60 Hz ±5% (auto sensing)
AC Output
Voltage (Selectable): 100/110/120VFrequency: 50 or 60Hz ±0.5% when on batteryRegulation: ±10% nominalSpike Protection: 320 Joules, 2msEMI/RFI Filtering: 10dB at 0.15MHz, 50dB at 30mHzOverload Capacity: 125% for 10min, 150% for 10secTransfer Time: 2 to 4ms, including detection timeWaveform: Sine wave
Battery
Recharge Time: <5hrs to 90% recharge of internal batteries onlyType: Valve Regulated Lead Acid (VRLA)
Extended battery connectors included Extended battery packs available
InterfaceFront Panel Indicators: LED display – load level and battery
capacity.Audible Alarm: On battery – Slow beep, low battery – rapid
beep, overload – continuousCommunications: RS-232 with optional ethernet/SNMP.
EnvironmentOperating Temperature:
0 to 40°C
Storage Temperature: -20 to 48°CAltitude: 3500m above sea levelHumidity: 0 to 95% non-condensingSafety: UL, CSA
Warranty UPS Module and Battery:
Competitive warranties included. Contact your sales representative for further details.
Line InteractiveALI Elite XL
All the same features and benefits of the ALI Elite with the capability of longer run times.
Nominal Specifications
Model
Tower: ALI Elite 1000TXL ALI Elite 1500TXL ALI Elite 2000TXL ALI Elite 3000TXL
Part Number: 017-747-210 017-747-215 017-747-220 017-747-230
Rack Mount: ALI Elite 1000RMXL ALI Elite 1500RMXL ALI Elite 2000RMXL ALI Elite 3000RMXL
Part Number: 017-747-81 017-747-85 017-747-82 017-747-83
Capacity VA/W: 1000VA/600W 1500VA/900W 2000VA/1200W 3000VA/1800W
Input Plug: NEMA 5-15P NEMA 5-15P NEMA L5-20P NEMA L5-30P
Input Protection: Fuse Fuse Breaker Breaker
Audible Noise: <40dBA @ 1m <45dBA @ 1m <45dBA @ 1m <45dBA @ 1m
Receptacles
Tower: 6 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-20R 4 NEMA 5-15R, 1 NEMA 5-30R
Rack Mount: 6 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-20R 4 NEMA 5-15R, 1 NEMA 5-30R
Battery
DC Voltage: 24V 36V 48V 48V
Mechanical
Tower
(in): 6.7W x 17.7D x 8.9H 6.7W x 18.9D x 16.9H 6.7W x 18.9 x 16.9H 6.7W x 21.6D x 16.9H
(mm): 170.2W x 449.6D x 226.1H 170.2W x 480.1D x 429.3H 170.2W x 480.1D x 429.3H 170.2W x 548.6D x 429.3H
Weight (lb/kg): 66/30 94.8/46 110.2/50 125.7/57
Approx. Ship Weight (lb/kg): 70.5/32 108/49 116/53 132/60
Rack Mount
(in): 16.9W x 22.0D x 5.1H 16.9W x 22.0D x 5.1H 16.9W x 22.0D x 5.1H 16.9W x 22.0D x 7.0H
(mm): 429.3W x 558.2D x 129.5H 429.3W x 558.2D x 129.5H 429.3W x 558.2D x 129.5H 429.3W x 558.2D x 177.8H
Weight (lb/kg): 41.9/19 52.9/24 59.5/27 103.6/47
Approx. Ship Weight (lb/kg): 46.2/21 57.3/26 63.7/29 108/49
34
Ind
oo
r S
olu
tio
ns
Alpha AC Catalogue 2008 For Prin34 34 7/30/2008 3:03:35 PM
Line InteractiveAli Elite XL
Specifications
Battery Pack: ALIBP700/1000T ALIBP1500T ALIBP2/3000T
Alpha Part Number: 033-747-07 033-747-10 033-747-20
Dimensions (in): 6.7W x 18.9D x 8.5H 6.7W x 18.9D x 8.5H 6.7W x 18.9D x 8.5H
(mm): 170.2W x 480.1D x 215.9H 170.2W x 480.1D x 215.9H 170.2W x 480.1D x 215.9H
Weight (lb/kg): 69.4/31.5 56.2/25.5 69.4/31.5
Approx. Ship Weight (lb/kg): 73.9/33.5 60.6/27.5 73.9/33.5
Specifications
Battery Pack: ALIBP700/1000RM ALIBP1500RM ALIBP2/3000RM
Alpha Part Number: 033-747-08 033-747-12 033-747-22
Dimensions (in): 16.9W x 15.7D x 5.1H 16.9W x 15.7D x 5.1H 16.9W x 15.7D x 5.1H
(mm): 429.3W x 398.8D x 129.5H 429.3W x 398.8D x 129.5H 429.3W x 398.8D x 129.5H
Weight (lb/kg): 64.5/29.65 64.5/29.65 64.5/29.65
Approx. Ship Weight (lb/kg): 72.6/32.95 72.6/32.95 72.6/32.95
ALI Elite Extended Run Time Battery PackThe ALI Elite also has optional battery packs to further extend your run time during a power failure. Review the table below to find a solution to best fit your needs.
Battery Runtimes*
ALI Elite 1000 TXL/RMXL ALI Elite 1500 TXL/RMXL ALI Elite 2000 TXL/RMXL ALI Elite 2000 TXL/RMXL
Tower at 50% Load
UPS: 36 min 53 min 53 min 29 min
1 EBP: 202 min 123 min 123 min 78 min
2 EBP: 369 min 202 min 202 min 123 min
Tower at 100% Load
UPS: 12 min 19 min 19 min 9 min
1 EBP: 92 min 53 min 53 min 29 min
2 EBP: 163 min 92 min 92 min 53 min
Rack at 50% Load
UPS: 36 min 16 min 16 min 15 min
1 EBP: 212 min 126 min 102 min 66 min
2 EBP: 416 min 248 min 189 min 120 min
Rack at 100% Load
UPS: 13 min 6 min 6 min 5 min
1 EBP: 97 min 54 min 40 min 26 min
2 EBP: 179 min 111 min 86 min 52 min
*rounded to the nearest minute
ALI Elite XL
35
Indo
or S
olutio
ns
Alpha AC Catalogue 2008 For Prin35 35 7/30/2008 3:03:36 PM
General Specifications
AC Input
Voltage Range: 80 to 144V at full load, 60 to 144V at 40% load (120V Units)
Frequency: 50/60Hz ±5% (auto sensing)
AC Output
Voltage (selectable): 100/110/115/120/127V (PIN 1000 to 3K)
Frequency: 50 or 60Hz ±0.5% when on battery
Receptacle Segments: 2 – software controllable
Voltage THD, Linear Load: <3%
Crest Factor: 3:1
Overload Capacity: 125% for 1min, 150% for 10sec
Transfer Time: 0ms
Extended Battery
Recharge Time:
Type:
<4hrs to 90% recharge on internal battery
Valve Regulated Lead Acid (VRLA)
Extended battery connection included.
Extended battery packs available
Interface
Front Panel Indicators: LCD display/input/output volts, frequency, load level, battery capacity, online/eco mode
Audible Alarm: On Battery – 5 second interval, UPS fault – continuous
Communications: RS-232, communications expansion slot, USB standard (Options: AS400 Card,
UPS LAN Card)
Environment
Operating Temperature: 0 to 40°C
Storage Temperature: -20 to 50°C
Altitude: 3500m above sea level
Humidity: 0 to 95%, non-condensing
Audible Noise: <40dBA at 1m
Safety: UL, CSA
EMC (EMS/EMI): IEC 61000-4. FCC Part 15, CISPR22
High Efficiency Mode: >95% efficient when selected
Double ConversionPinnacle Plus
1000VA to 3000VA models to meet your power needs
True online, double conversion operation (zero transfer time)
Internal Static Bypass: no extra parts to buy for complete operation
Power factor correction: minimize energy consumption
Optional Ethernet SNMP communications interface: monitor from anywhere
Hot swappable batteries: no downtime
The Pinnacle Plus Uninterruptible Power Supply (UPS), in tower or rack mount configurations provides safe, clean, reliable power protection to data and voice networking equipment, telecommunication systems, servers and other mission-critical applications. The Pinnacle Plus offers an advanced fully microprocessor controlled technology that quickly reacts to varying output conditions and continually offers pure sine wave power to critical equipment with zero transfer time. The advanced, scalable battery charger shortens the battery recharge time while prolonging the life of the battery. With true RS-232 & USB two-way communication that sends signals to both the network and computer, the Pinnacle Plus can be monitored, shut down, or programmed with an on/off date, using its own software. Simplified control circuits make it light, easy to control, and reliable due to the reduction of internal components.
Pinnacle Plustower configuration
Pinnacle Plus rack configuration
36
Ind
oo
r S
olu
tio
ns
Alpha AC Catalogue 2008 For Prin36 36 7/30/2008 3:03:37 PM
37
Nominal Specifications
ModelTower: PINNACLE Plus 1000T PINNACLE Plus 1500T PINNACLE Plus 2000T PINNACLE Plus 3000TPart Number: 017-751-10 017-751-15 017-751-20 017-751-30Rack Mount 2U: PINNACLE Plus 1000RM PINNACLE Plus 1500RM PINNACLE Plus 2000RM PINNACLE Plus 3000RMPart Number: 017-751-122 017-751-17 017-751-22 071-751-32Capacity (VA/W): 1000VA/700W 1500VA/1050W 2000VA/1400W 3000VA/2100WInput Plug: NEMA 5-15P NEMA 5-15P NEMA L5-20P NEMA L5-30PInput Protection: Circuit Breaker 12A Circuit Breaker 15A Circuit Breaker 20A Circuit Breaker 30AReceptaclesTower: 6 NEMA 5-15R 6 NEMA 5-15R 10 NEMA 5-20R, 1NEMA L5-20R 10 NEMA 5-15R, 1 NEMA L5-30RRack Mount: 6 NEMA 5-15R 6 NEMA 5-15R 2 NEMA 5-20R, 1 NEMA L5-20R 2 NEMA 5-15R, 1 NEMA L5-30RBatteryDC Voltage: 36V 36V 72V 72VMechanicalTowerDimensions (in): 6W x 16.5D x 9.4H 6W x 16.5D x 9.4H 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H (mm): 152.4W x 419.1D x 238.8H 152.4W x 419.1D x 238.8H 226.1W x 424.2D x 360.7H 226.1W x 424.2D x 360.7HNet Weight (lb/kg): 35.3/17.1 37.5/17.7 68.3/33.8 72.8/35.6Approx. Ship Weight. (lb/kg):
40/18.9 41.8/19.5 73.9/36 78.1/38
Rack MountDimensions (in): 16.9W x 16.7D x 3.3H 16.9W x 16.7D x 3.3H 16.9W x 25D x 3.3H 16.9W x 25D x 3.3H (mm): 429.3W x 424.2D x 83.8H 429.3W x 424.2D x 83.8H 429.3W x 609.6D x 83.8H 429.3W x 609.6D x 83.8HNet Weight (lb/kg): 37.5/18.7 39.7/19.1 70.6/33.6 72.8/34.3Approx. Ship Weight (lb/kg):
42.5/21.6 44.2/21.7 74.4/36.7 78.5/38.3
Battery Runtimes*Tower at 50% LoadUPS: 18min 14min 18min 14min1 EBP: 148min 92min 80min 50min2 EBP: 310min 205min 150min 93minTower at 100% LoadUPS: 6min 5min 6min 5min1 EBP: 69min 38min 33min 19min2 EBP: 150min 80min 69min 40minRack at 50% LoadUPS: 18min 14min 18min 14min1 EBP: 148min 92min 80min 50min2 EBP: 310min 205min 150min 93minRack at 100% LoadUPS: 6min 5min 6min 5min1 EBP: 69min 38min 33min 19min2 EBP: 150min 80min 69min 40min
*rounded to the nearest minute
Double ConversionPinnacle Plus
Indo
or S
olutio
ns
Alpha AC Catalogue 2008 For Prin37 37 7/30/2008 3:03:38 PM
38 General Specifications
AC Input
Voltage Range: 180 to 276 VAC
Frequency: 50/60Hz ±5% (auto sensing)
AC Output
Voltage (selectable): 200/208/220/230/240
Frequency: 50 or 60Hz ±0.5% when on battery
Receptacle Segments: 2 – software controllable
Voltage THD, Linear Load: <3%
Crest Factor: 3:1
Overload Capacity: 125% for 1min, 150% for 10sec
Transfer Time: 0ms
Extended Battery
Recharge Time:
Type:
<4hrs to 90% recharge on internal battery
Valve Regulated Lead Acid (VRLA)
Extended battery connection included.
Extended battery packs available
Interface
Front Panel Indicators: LCD display/input/output volts, frequency, load level, battery capacity, online/eco mode
Audible Alarm: On Battery – 5 second interval, UPS fault – continuous
Communications: RS-232, communications expansion slot, USB standard (Options: AS400 Card,
UPS LAN Card)
Environment
Operating Temperature: 0 to 40°C
Storage Temperature: -20 to 50°C
Altitude: 3500m above sea level
Humidity: 0 to 95%, non-condensing
Audible Noise: <40dBA at 1m
Safety: UL, CSA
EMC (EMS/EMI): IEC 61000-4. FCC Part 15, CISPR22
High Efficiency Mode: >95% efficient when selected
Double ConversionPinnacle Plus High Power
6000, 10,000 and 12,000W/VA models to meet every power need
True online, double conversion operation (zero transfer time)
Internal Static Bypass: no extra parts to buy for complete operation
Power factor correction: minimize energy consumption
Optional Ethernet SNMP communications interface: monitor from anywhere
Hot swappable batteries: no downtime
The Pinnacle Plus Uninterruptible Power Supply (UPS), in tower or rack mount configurations provides safe, clean, reliable power protection to data and voice networking equipment, telecommunication systems, servers and other mission-critical applications. The Pinnacle Plus offers an advanced fully microprocessor controlled technology that quickly reacts to varying output conditions and continually offers pure sine wave power to critical equipment with zero transfer time. The advanced, scalable battery charger shortens the battery recharge time while prolonging the life of the battery. With true RS-232 two-way communication that sends signals to both the network and computer, the Pinnacle Plus can be monitored, shut down, or programmed with an on/off date, using its own software. Simplified control circuits make it light, easy to control, and reliable due to the reduction of internal components.
Pinnacle Plus High Powertower configuration(available Q4, 2008)
Ind
oo
r S
olu
tio
ns
Alpha AC Catalogue 2008 For Prin38 38 7/30/2008 3:03:38 PM
Extended Run Time Battery Pack Specifications for Pinnacle Plus Tower
Battery Pack: PINBP1000/1500T PINBP1000/1500T PINBP2/3000T PINBP2/3000T PINBP6000T PINBP10000/12000T
Alpha P.N.: 033-751-10 033-751-10 033-751-20 033-751-20 033-751-400 017-751-311
Dimensions (in): 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H 8.9W x 16.7D x 14.2H 10.2W x 27.4D x 22.4H13.5W x 24.1D x 25.9H/ 13.5W x 24.5D x 25.96H
(mm): 226W x 424D x 360H 226W x 424D x 360H 226W x 424D x 360H 226W x 424D x 360H 258W x 697D x 570H344W x 613D x 657H/ 344W x 623D x 657H
Weight (lb/kg): 92.6/42 92.6/42 92.6/42 92.6/42 Contact Alpha Contact Alpha
Approx. Ship Weight (lb/kg):
98.1/44.5 98.1/44.5 98.1/44.5 98.1/44.5 Contact Alpha Contact Alpha
Extended Run Time Battery Pack Specifications for Pinnacle Plus Rack Mount
Battery Pack: PINBP1000/1500RM PINBP1000/1500RM PINBP2/3000RM PINBP2/3000RM
Alpha Part Number: 033-751-12 033-751-12 033-751-22 033-751-22
Dimensions (in): 16.9 x 25 x 3.3H 16.9 x 25 x 3.3H 16.9 x 25 x 3.3H 16.9 x 25 x 3.3H
(mm): 429.3W x 635D x 83.8H 429.3W x 635D x 83.8H 429.3W x 635D x 83.8H 429.3W x 635D x 83.8H
Weight (lb/kg): 95.9/43.5 95.9/43.5 95.9/43.5 95.9/43.5
Approx. Ship Weight (lb/kg): 101.4/46 101.4/46 101.4/46 101.4/46
Double ConversionPinnacle Plus High Power
ModelTower PINNACLE Plus 6000T PINNACLE Plus 10000T PINNACLE Plus 12000TPart Number: 017-751-400 017-751-300 017-751-580Capacity (VA/W): 6000VA/4200W 10000VA/7000W 12000VA/8400W Input Plug: Terminal Block Terminal Block Terminal BlockInput Protection: Circuit Breaker Circuit Breaker Circuit BreakerReceptaclesTower: Terminal Block Terminal Block Terminal BlockBatteryDC Voltage: 240V 240V 240V MechanicalTowerDimensions (in): 10.1W x 23.2D x 22.4H 10.1W x 27.2D x 28.2H 13.5W x 27.2D x 34.6H(mm): 257.8W x 699.8D x 699.4H 324.4W x 739.2D x 729.4 H 342W x 690D x 903HNet Weight (lb/kg): 209 / 95 332 / 151 435 / 198Approx. Ship Weight (lb/kg): Contact Alpha Contact Alpha Contact AlphaBattery RuntimesTower at 50% LoadUPS: 19min 37min 53minTower at 100% LoadUPS: 6min 13min 19min
39
Indo
or S
olutio
ns
Alpha AC Catalogue 2008 For Prin39 39 7/30/2008 3:03:38 PM
One of the highest MTBF in the UPS industry - lowers total cost of ownership
Complete input to output isolation provides complete surge and lightning protection for sensitive loads
The CFR’s microprocessor design provides efficiency ratings up to 92%, saving energy
Features a RS-232 communication port and is SNMP and modem compatible for monitoring from any Internet connection location
Alpha CFR Uninterruptible Power Supplies (UPS) meet or exceed the safety standards established by UL, CSA, CE and VDE. The Alpha CFR UPS is one of the most reliable UPS systems available, with a wide variety of plug and receptacle options to meet your unique connection requirements. Input current waveform correction eliminates overheating effects of non-linear load current harmonics. Input power-factor correction brings low power-factor loads to near unity, reducing electric utility costs. The CFR Series sets the standard for the effective powering of non-linear or actively regulated loads, while providing superior surge and noise rejection. Power ratings of 1000VA to 15kVA available.
Controlled Ferroresonant CFR®
CFR Series
40
Ind
oo
r S
olu
tio
ns
Alpha AC Catalogue 2008 For Prin40 40 7/30/2008 3:03:39 PM
Common Specifications
Operating Input Voltage Range: -23 to 10%
Input Frequency Operating Range: ±1.4Hz
Input Power Factor 0.95 to 0.99
Input Current THD: 5% Typical
Output Waveform: Pure sine wave
Output Voltage Regulation: ±1%
Typical Output Voltage THD: <5% 600VA to 5kVA
Inverter Frequency Stability: ±0.1%
Spike Attenuation: 2000 to 1
Lightning & Surge Protection: ANSI C62.41-1980
(IEEE 587)
Operating Temperature: 0 to 40°C (32 to 104°F)
Audible Noise: 40dBA Typical @ 1m
Communications
All Alpha CFR products feature RS-232 communication ports and are SNMP and modem compatible.
The following is a list of optional communication, monitoring and control products:
SNMP Agent: Furnishes real time UPS/power status to Network Power Management Software.
Intelligent Interface Device (I2D): Front panel LCD readout provides vital UPS system information at the touch of a key.
EBP Options
Alpha’s plug-in External Battery Packs provide extended backup for all CFR models. All battery packs are shipped fully assembled and include interconnecting cables. Longer runtimes are obtained by cascading additional battery cabinets.
Available for:
CFR 1000
Battery Pack 24V EBP 24A EPB 24C EBP 24E Width (in/mm): 8.5/216 8.5/216 8.5/216 Height (in/mm): 4.5/114 10.5/267 21.5/546
Depth (in/mm): 15.5/39424.0/610
28.0/711
Weight (lb/kg): 39/18 127/58 312/141 Capacity (Ah): 17 66 176
Available for:
CFR 1500, 2500, 3000
Battery Pack 48V EBP 48A EBP 48E Width (in/mm): 8.5/216 8.5/216 Height (in/mm): 10.5/267 21.5/546 Depth (in/mm): 10.5/267 21.5/546 Weight (lb/kg): 127/58 312/141 Capacity (Ah): 33 88
Application Specific Models
CFR-NT: Specifically designed to be compatible with Northern Telecom Meridian telephone switches and other telephony products
CFR-E: 50Hz configuration
Plug and Receptacle Diagram5-15P 5-15R CS63615-30P 5-30R Terminal
Block5-20P 5-20R British5-50P L5-15R SchukoL5-15P L5-20R Australian
L5-30P L5-30R L6-30P L6-20R L6-30R
Available for:
CFR 5000
Battery Pack 48V EBP 48M EBP 1275-48B Width (in/mm): 8.5/216 22.0/660 Height (in/mm): 21.5/564 30.3/770 Depth (in/mm): 28.0/711 31.5/800 Weight (lb/kg): 312/141 905/411 Capacity (Ah): 88 264
Controlled Ferroresonant CFR®
41
Indo
or S
olutio
ns
Alpha AC Catalogue 2008 For Prin41 41 7/30/2008 3:03:41 PM
Nominal Specifications
Model Number:CFR 1000CFR 1000 E
CFR 1500CFR 1500 ECFR 1500 NT
CFR 2000CFR 2000 ECFR 2000 NT
CFR 2500CFR 2500 ECFR 2500 NT
CFR 3000CFR 3000 ECFR 3000 NT
CFR 5000CFR 5000 ECFR 5000 NT
Output Power Rating: 1000VA 1500VA 2000VA 2500VA 3000VA 5000VA750W 1000W 1334W 1667W 2000W 3750W
60Hz Models (CFR, CFR-NT & CFR-M)Input Voltage (VAC) Nominal: 120 120/208/240 120/208/240 120/208/240 120/208/240 120/208/240Output Voltage (VAC) Nominal: 120 120/208/240 120/208/240 120/208/240 120/208/240 120/208/24050Hz Models (CFR-E)Input/Output Voltage (VAC) Nominal: 230 230 230 230 230 230 Typical Efficiency -AC/AC 100% Load: 90% 90% 90% 90% 90% 90%Typical Heat Output - Line Mode: 284 BTU/h 427 BTU/h 398 BTU/h 636 BTU/h 758 BTU/h 1425 BTU/h MechanicalWidth (in/mm): 8.5/216 8.5/216 8.5/216 8.5/216 8.5/216 12/305Height (in/mm): 10/254 21/533 21/533 21/533 21/533 22.5 /569 Depth (in/mm): 20/508 22.5/571 22.5/571 22.5/571 29.5/749 29.4/74760Hz Weight (lb/kg): 92/42 151/69 171/78 185/84 283/128 375/170 60Hz Ship Weight (lb/kg): 97/44 162/73 182/83 200/91 312/142 453/20650Hz Weight (lb/kg): 93.42 163/74 181/82 190/86 313/142 381/173 50Hz Ship Weight (lb/kg): 98/44 174/79 192/87 205/93 332/151 477/216Internal Battery Runtime 100%*: 12min 18min 15min 10min 27min 12minInternal Battery Recharge Time: (To 80% of Capacity)
5hrs typical 5hrs typical 5hrs typical 5hrs typical 5hrs typical 5hrs typical
Extended Battery Runtime Options*A. External Battery Pack (EBP): EBP 24A EBP 48A EBP 48A EBP 48A EBP 48A EBP 48M Total Runtime**: 32min 1hr 39min 1hr 10min 52min 1hr 15min 1hr 15minB. External Battery Pack (EBP): EBP 24C EBP 48E EBP 48E EBP 48E EBP 48E EBP 1275-48B Total Runtime**: 2hrs 12min 3hrs 45min 2hrs 48min 2hrs 10min 2hrs 30min 3hrs 44minC. External Battery Pack (EBP): EBP 24E Total Runtime**: 5hrs 12min 60Hz Power Connector Options†
Input: CFR, CFR-C, CFR-M, CFR-RM Models:
5-15P5-15PL5-15P T. B.
5-20PL5-20P T. B.
5-30PL5-30PL6-30PT. B.
5-30PL5-30PL6-30PTerminal Block
5-50PCS6361L6-30P***Terminal Block
CFR-NT Models: N/A L6-30R L6-30R L6-30R L6-30 L6-30Output: CFR, CFR-C, CFR-M, CFR-RM Models:
5-15R
L5-15R
5-15R 5-20R6-20R L5-15R L5-20R L5-30R L6-20R 5-30RL6-30R T. B.
5-15R 5-20R6-20R L5-15R L5-20R L5-30R L6-20R 5-30RL6-30R T. B.
5-15R 5-20R6-20R L5-15R L5-20R L5-30R L6-20R 5-30RL6-30R T. B.
5-15R5-20R6-20RL5-15RL5-20RL5-30RL6-20R5-30RL6-30RTerminal Block
5-15R5-20R6-20RL5-15RL5-20RL5-30RL6-20R5-30RL6-30RTerminal Block
CFR-NT Models: N/A 5-15R 2-L6-30R
5-15R 2-L6-30R
5-15R 2-L6-30R
5-15R2-L6-30R
5-15R3-L6-30R
50Hz Power Connector Options†Input /Output: CFR-E Models: British
SchukoAustralian
BritishSchukoAustralian
BritishSchukoAustralian
BritishSchukoAustralianT.B.
BritishSchukoAustralianT.B.
BritishSchukoAustralianT.B.
Output Power Connector Configuration Options: 1) Any 2 single or 2 duplex receptacles 1) Any combination of 3 or less duplex receptacles 2) Any combination of 2 or less single receptacles 3) Any duplex receptacle with any single receptacle 4) Single terminal blockUPS Warranty: 24 month limited warrantyBattery: 24 month limited warranty* Battery runtimes are calculated at 100% rated loads and will vary according to battery age, loads, temperature and other factors.** Total runtime include the internal batteries and the External Battery Pack (EBP) at 100% load.† Refer to Plug and Receptacle Diagram on last page.
Controlled Ferroresonant CFR®
42
Ind
oo
r S
olu
tio
ns
Alpha AC Catalogue 2008 For Prin42 42 7/30/2008 3:03:42 PM
Maximum power protection for complete isolation and uninterruptible power, assuring the ongoing performance of sensitive medical equipment
Meets demanding UL 60601-1 medical safety standards, allowing use in most medical and healthcare environments
Low current leakage supports patient vicinity equipment
Optional external battery packs greatly extend backup time
Generator compatibility meets even the longest runtime requirements
Clean, safe reliable power is critical to the health care industry. The AlphaMED® is the answer. The AlphaMED® ensures clean, reliable power, pure sine wave output power to within one percent of the nominal voltage requirement and meets the most stringent lowest leakage current requirements in the industry. Sophisticated medical equipment such as ultrasound systems, film processors, laboratory systems, and other health care devices need optimal power protection, as well as a low audible noise level. The AlphaMED® external battery packs greatly extend the backup time (up to 8 hours) allowing users to work through power outages and disturbances without interruption, rather than shutting down critical medical equipment.
Featuring an intelligent user interface, the AlphaMED® provides information and power management capacity on stand-alone or network configuration. RS-232 port, Ethernet/SNMP compatibility and remote call-out paging adds to the UPS’s advanced communications functions. Each unit comes with an automatic self-test capability and can provide an orderly, unattended shutdown of medical systems in the event of an extended power outage.
AlphaMED
AlphaMED back panel
Controlled Ferroresonant - Health CareAlphaMED®
43
Indo
or S
olutio
ns
Alpha AC Catalogue 2008 For Prin43 43 7/30/2008 3:03:43 PM
Available for:
CFR 1500, 2500, 3000
Battery Pack 48V EBP 48A EBP 48E EBP 1275-48RWidth (in/mm): 8.5/216 8.5/216 22.0/660Height (in/mm): 10.5/267 21.5/546 30.3/770Depth (in/mm): 10.5/267 21.5/546 31.5/800Weight (lb/kg): 127/58 312/141 905/411Capacity (Ah): 33 88 264
Nominal Specifications
Model Number: AlphaMED® 1000 AlphaMED® 1000E
AlphaMED® 1500 AlphaMED® 1500E
AlphaMED® 2000 AlphaMED® 2000E
AlphaMED® 2500 AlphaMED® 2500E
AlphaMED® 3000
AlphaMED® 3000EOutput Power Rating: 1000VA / 750W 1500VA / 1000W 2000VA / 1334W 2500VA / 1667W 3000VA / 2000WInput/Output Voltage (VAC) Nominal:
120 230
120/208/240* 230
120/208/240* 230
120/208/240* 230
120/208/240* 230
Typical Efficiency - AC/AC 100% Load:
90% 90% 90% 90% 90%
Typical THD: 5% 5% 5% 5% 5%Typical Heat Output - Line Mode:
427BTU/h 398BTU/h 636BTU/h 758BTU/h
Audible Noise at 1m: <38dBA <38dBA <39dBA <39dBA <39dBAWaveform: sine sine sine sine
Noise Attenuation
Common Mode (100k to 1MHz):
-120dB -120dB -120dB -120dB -120dB
Normal Mode (100k to 1MHz): -60 dB -60dB -60dB -60dB -60dBOperation Temperature (˚F/˚C): 32 to 104/0 to 40 32 to 104/0 to 40 32 to 104/0 to 40 32 to 104/0 to 40 32 to 104/0 to 40Mechanical
Width (in/mm): 8.5/216 8.5/216 8.5/216 8.5/216 8.5/216Height (in/mm): 10/254 21/533 21/533 21/533 21/533Depth (in/mm): 20/508 22.5/571 22.5/571 22.5/571 29.5/749Weight (lb/kg): 92/42 151/69 171/78 185/84 283/128Internal Battery Runtime**: 18min 15min 10min 27minMax. Battery Charger Current: 3A 3A 3A 3A 3ABattery Recharge Time: 5 hrs typical 5hrs typical 5hrs typical 5hrs typical 5hrs typicalExtended Battery Run Time Options* A. External Battery Pack (EBP): EBPA EBP 48A EBP 48A EBP 48A EBP 48A Total Runtime***: 1hr 39min 1hr 10min 52min 1hr 15minB. External Battery Pack (EBP): EBPA EBP 48E EBP 48E EBP 48E EBP 48E Total Runtime***: 3hrs 45min 2hrs 48min 2hrs 10min 2hrs 30min
* Factory configured** Battery runtimes are calculated at 100% load and will vary according to battery age, loads, temperature and other factors.*** Total runtime include the internal batteries and the External Battery Pack (EBP).
Agency Compliance
Marks: CSA 107.1-01, CAN/CSA 601.1-M90
Safety: UL 1778 (2nd Edition), UL Std No 60601-1 (1st Edition)
Power Connector Options
Input: Hospital Grade NEMA STD:
Output: Hospital Grade NEMA STD:
Output Power Connector Configuration Options
1) Any combination of 3 or less duplex receptacles. 2) Any combination of 2 or less single receptacles. 3) Any duplex receptacle with any single receptacle. 4) Single terminal block. (Other Configurations may be available)
EBP Options Alpha’s plug-in External Battery Packs provide extended backup for all CFR models.
All battery packs are shipped fully assembled and include interconnecting cables.
Longer runtimes are obtained by cascading additional battery cabinets.
Controlled Ferroresonant - Health CareAlphaMED®
44
Ind
oo
r S
olu
tio
ns
Alpha AC Catalogue 2008 For Prin44 44 7/30/2008 3:03:45 PM
True on-line topology
Very high efficiency
Transformerless technology
Dual input power sources for optimum reliability
Digital Power Quality IGBT inverter technology
Advanced battery management for maximum battery life
Generator friendly
Compact footprint
Network based software for multi-server control
SNMP manageable
Graphical User Interface with color touch screen
Scalable power levels
Whether you are protecting a large server farm or air traffic control tower, the COMET UPS has proven to be the most reliable solution for mid-range power protection applications. The COMET uses a true on-line topology regenerating 100% of the output power to guarantee complete isolation and protection from all utility power problems. Combined with features like 95% efficiency, less than 3.5% output distortion and unique Digital Power Quality IGBT inverter technology the COMET also boasts some of the most favorable specifications of any UPS. Trusted by IT professionals as the industry standard solution, COMET has now become one of the best selling UPSs in its class.
Three PhaseComet
Comet
45
Indo
or S
olutio
ns
Alpha AC Catalogue 2008 For Prin45 45 7/30/2008 3:03:46 PM
Nominal Specifications
Model: 50 Series 80 Series 150 SeriesOutput Power: 40kVA/32kW 50kVA/40kW 65kVA/52kW 80kVA/64kW 100kVA/80kW 125kVA/100kW 150kVA/120kWInput Voltage (VAC L-L): 208 480 480 600 208 480 480 600 208 480 480 600 208 480 480 600 208 480 480 600 208 480 480 600 208 480 480 600Output Voltage (VAC L-L): 208 208 480 208 208 208 480 208 208 208 480 208 208 208 480 208 208 208 480 208 208 208 480 280 208 208 480 208
AC Input (With Standard Input Filter)Max. Current (A): 131 57 57 45 164 71 71 56 212 92 92 74 261 113 113 91 301 128 125 107 371 158 154 129 444 182 182 154
ByPass InputNominal Current (A): 111 48 48 39 139 60 60 48 180 78 78 63 222 96 96 77 256 109 106 91 316 134 130 109 378 160 155 131
AC OutputNominal Current (A): 111 111 48 111 139 139 60 139 180 180 78 180 222 222 96 222 278 278 120 278 347 347 150 347 416 416 180 416
DC LineNominal Voltage (VDC) @ 25°C: 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432 432Float Voltage (VDC) @ 25°C: 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490 490End of Discharge (VDC) @ 25°C: 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361 361Max. Amps (VDC) @ Cutoff: 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123 123
UPS Mechanical SpecificationsDepth (in): 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34Depth (cm): 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86 86Height (in): 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67 67Height (cm): 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170 170
Single Input1
Installed Weight (lb): 1760 1360 880 2460 1760 1360 880 2460 2115 1590 970 2690 2115 1590 970 2690 3400 2450 1450 3400 3400 2450 1450 3400 3400 2450 1450 3400Installed Weight (kg): 798 617 399 1274 798 617 399 1274 964 721 440 1503 959 721 440 1503 1542 1111 658 1542 1542 1111 658 1542 1542 1111 658 1542Installed Width (in): 33 33 33 59 33 33 33 59 33 33 33 59 33 33 33 59 69 43 43 69 69 43 43 69 69 43 43 69Installed Width (cm): 84 84 84 150 84 84 84 150 84 84 84 150 84 84 84 150 175 109 109 175 175 109 109 175 175 109 109 175
Dual Input2
Added Installed Weight (lb): 1110 — — 1650 1100 — — 1650 1100 — — 1650 1100 — — 1650 1100 — — 1650 1100 — — 1650 1100 — — 1650Added Installed Weight (kg): 499 — — 748 499 — — 748 499 — — 748 499 — — 748 726 — — 748 726 — — 748 726 — — 748Total Installed Width (in): 59 33 33 85 59 33 33 85 59 33 33 85 59 33 33 85 95 43 43 95 95 43 43 95 95 43 43 95Total Installed Width (cm): 150 84 84 216 150 84 84 216 150 84 84 216 150 84 84 216 241 109 109 241 241 109 109 241 241 109 109 241
System Efficiencies@ 100% Load (%): 90 90 93 90 90 90 93 90 91 92 94 91 91 91 94 91 91 93 95 91 90 92 95 90 90 92 94 90@ 75% Load (%): 90 91 94 90 90 91 94 90 91 92 94 91 91 91 94 91 91 93 95 91 91 93 95 91 90 92 95 90@ 50% Load (%): 89 90 93 89 89 90 93 89 91 92 94 91 91 91 94 91 89 91 94 89 90 92 94 90 90 93 95 90
Full Load Heat DissipationBTU/hr. (x 1000): 16.9 15.2 10.3 16.9 16.9 15.2 10.3 16.9 17.6 15.4 11.3 17.6 21.6 18.9 13.9 21.6 28.3 22.3 15.4 28.3 38.2 30.7 20.8 38.2 50.7 41.6 26.3 50.7Watts (x 1000): 4.9 4.4 3 4.9 4.9 4.4 3 4.9 5.2 4.5 3.3 5.2 6.3 5.5 4 6.3 8.3 6.5 4.5 8.3 11.2 8.9 6.1 11.2 14.9 12.2 7.7 14.9
Note: Adjacent battery pack width not included with UPS.1. Single Input feeds both the Bypass and the Inverter.2. Dual input has separate feed for both the Bypass and the Inverter. Weight to be added. Auxiliary cabinet included where required.
Battery Pack Options
RuntimesBattery Type Qty. per Cabinet 40kVA (min) 50kVA (min) 65kVA (min) 80kVA (min) 100kVA (min) 125kVA (min) 150kVA (min)NPX 150R: 36 12 10 6 — — — — UPS 12-270F: 36 28 23 17 12 8 5 — UPS 12-370F: 36 45 36 25 20 15 10 7UPS 12-475F: 36 65 52 36 28 19 13 9UPS 12-270F: 72 73 60 45 31 25 18 13.5UPS 12-370F: 72 100 80 60 46 36 26 21UPS 12-270F: 108 110 90 72 56 42 31 25UPS 12-475F: 72 150 120 94 60 56 37 30UPS 12-370F: 108 195 156 115 76 60 46 36UPS 12-475F: 108 250 198 145 92 69 60 51Note: Runtimes are listed at full load.
Battery Mechanical Specifications: NPX 150R UPS 12-270F UPS 12-30F UPS 12-475FWeight (lb/kg): 1878/852 2750/1247 3380/1533 4100/1860Width (in/cm): 26/66 32/81 48/122 48/122
For additional information about the AlphaSource 6000 (225 to 800kVA) please contact your local sales representative.
Three PhaseComet
46
Ind
oo
r S
olu
tio
ns
Alpha AC Catalogue 2008 For Prin46 46 7/30/2008 3:03:48 PM
Power ranges 40, 50, 65 and 75kVA
True online double conversion technology
IGBT rectifier
Low UPS to generator sizing
Power surge stabilization system
SNMP and network based power management options
Power factor corrected input SNMP and network based power management options
The Galaxy 4000 is designed for data center grade power protection in critical environments. Features include fault tolerant architecture to protect loads and the UPS unit during unintended faults, easy and quick to install, user-friendly graphical interface, web based monitoring options, and front only access. The IGBT rectifier minimizes input harmonics and power factor corrected input reduces installation costs due to smaller cabling and generator costs. The Galaxy 4000’s unique fault tolerant architecture safely manager output faults without compromising the UPS, while the Digital Power Quality Management System provides precision voltage regulation on a consistent bases. The UPS is also available as a UL 924 system for emergency lighting applications.
Galaxy 4000
Optional Features
RS232/RS485 serial interfaceEthernet/SNMP web card connection kitExternal maintenance bypass with interlockInternal maintenance bypassSeismic brackets42 pole distribution
Three PhaseGalaxy 4000
47
Indo
or S
olutio
ns
Alpha AC Catalogue 2008 For Prin47 47 7/30/2008 3:03:51 PM
Nominal Specifications
Output Power Rating: 40kVA 50kVA 65kVA 75kVA
Input
Voltage: 208V 208V 208V 208V
Frequency: 60Hz (±5%) 60Hz (±5%) 60Hz (±5%) 60Hz (±5%)
Power Factor: >0.98 >0.98 >0.98 >0.98
Current Distortion (THD): >3% >3% >3% >3%
Current (A @ 208V): 102 127 166 191
Output
Voltage: 208V 208V 208V 208V
Frequency: 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable) 60Hz (±1 to 4% selectable)
Transient Response: ±5% for 0 to 100% to 0% ±5% for 0 to 100% to 0% ±5% for 0 to 100% to 0% ±5% for 0 to 100% to 0%
Voltage Distortion THD: <1% L-L and L-N <1% L-L and L-N <1% L-L and L-N <1% L-L and L-N
Inverter Overload:130% for 1min 145% for 45sec
130% for 1min 145% for 45sec
130% for 1min 145% for 45sec
130% for 1min 145% for 45sec
Bypass Overload: 10x nominal current 10x nominal current 10x nominal current 10x nominal current
Output Current (A @ 208V): 111 139 180 208
Heat Rejection (max. BTUs): 14900 18700 24200 28000
Runtimes @ 100% Load
1 x 285W/Cell: 12 9 6 -
1 x 370W/Cell: 20 14 9 8
1 x 500W/Cell: 28 22 15 11
2 x 370W/Cell: 47 36 25 22
2 x 500W/Cell: 67 52 38 31
3 x 500W/Cell: 98 85 60 53
4 x 500W/Cell: 136 115 85 72
Mechanical Specifications
Standard Cabinet
Dimensions (in): 33.5W x 72.1H x 35.6D 33.5W x 72.1H x 35.6D 33.5W x 72.1H x 35.6D 33.5W x 72.1H x 35.6D
(mm): 851W x 1831H x 904D 851W x 1831H x 904D 851W x 1831H x 904D 851W x 1831H x 904D
Weight (lb/kg): 1235/560 1235/560 1235/560 1235/560
Battery Cabinet
Dimensions (in): 26.5W x 72.1H x 33.5D 26.5W x 72.1H x 33.5D 26.5W x 72.1H x 33.5D 26.5W x 72.1H x 33.5D
(mm): 673W x 1831H x 851D 673W x 1831H x 851D 673W x 1831H x 851D 673W x 1831H x 851D
Weight (lb/kg): 2045/928 2045/928 2045/928 2045/928
Second Battery Cabinet
Dimensions (in): 33.5W x 72.1H x 33.5D 33.5W x 72.1H x 33.5D 33.5W x 72.1H x 33.5D 33.5W x 72.1H x 33.5D
(mm): 851W x 1831H x 851D 851W x 1831H x 851D 851W x 1831H x 851D 851W x 1831H x 851D
Weight (lb/kg): 2745/1245 2745/1245 2745/1245 2745/1245
Standards:ISO 9001, UL 1778, cUL , FCC Part 15, subpart J, Class A, NEMA PE 1, NEMA 250, NFPA 70, IEC 10000 (801) level 4, OSHA
Three PhaseGalaxy 4000
48
Ind
oo
r S
olu
tio
ns
Alpha AC Catalogue 2008 For Prin48 48 7/30/2008 3:03:52 PM
Power ranges 10, 15, 20 and 30kVA
True online technology
Network-based power management
Input Power Factor Correction (PFC)
All-in-one complete solution
The Galaxy 3000 is the uninterruptible power supply design for mid-range data center enterprise level applications. The Galaxy 3000 delivers the optimum level of reliability, availability and scalability demanded by the new generation of critical enterprise applications. Clearly separated from the crowd by its robust Ultra High Availability Topology (UHAT), the Galaxy reacts to any circumstance in an inherently safe way to protect the critical load.
The true all-in-one design incorporates every feature into one compact cabinet, including animated graphical user interface, power factor corrected input, batteries and space for four communication cards. Combined with a scalable design, dual power feed option and generator friendly technology, the AlphaSource Galaxy is truly a quantum leap forward in critical power protection.
Galaxy 3000
Standard Features
Input distribution management
Digital power quality management system (PWM/IGBT inverter)
Step load voltage stabilization
Intelligent battery management system
Fault tolerant architecture
Scalable architecture (10 & 20kVA models)
No extra cabinet for isolation transformer
Integrated battery bank
Low audible noise fans (<53dBA)
Casters with leveling feet
Network based software for multi-server control
Dry contact i/o card
SNMP manageable
4 color graphic display with multilingual user interface
Bottom or top entry
Integrated maintenance bypass
Four communications ports
12 month warranty
Optional Features
Matching power distribution unit (84 circuits)
EIA232 / EIA485 serial interface
Ethernet/SNMP network connection kit
Dual input
External maintenance bypass
Input isolation transformer
Three PhaseGalaxy 3000
49
Indo
or S
olutio
ns
Alpha AC Catalogue 2008 For Prin49 49 7/30/2008 3:03:52 PM
Nominal Specifications
Output Power Rating: 10kVA 15kVA 20kVA 30kVA
Input
Voltage: 208/220/480/600 208/220/480/600 208/220/480/600 208/220/480/600
Frequency: 60Hz (-25 to 8%) 60Hz (-25 to 8%) 60Hz (-25 to 8%) 60Hz (-25 to 8%)
Power Factor: >0.99 >0.99 >0.99 >0.99
Current Distortion (THD): >3% >3% >3% >3%
Current (A @ 208V): 26 46 61 91
Breaker (@ 208): 40 60 80 125
Output
Voltage: 208 (220/480/600) 208 (220/480/600) 208 (220/480/600) 208 (220/480/600)
Frequency;60Hz (±1 to 4% selectable)
60Hz (±1 to 4% selectable)
60Hz (±1 to 4% selectable)
60Hz (±1 to 4% selectable)
Transient Response: ±3% for 0 to 100% to 0% ±3% for 0 to 100% to 0% ±3% for 0 to 100% to 0% ±3% for 0 to 100% to 0%
Voltage Distortion THD: <3% L-L and L-N <3% L-L and L-N <3% L-L and L-N <3% L-L and L-N
Inverter Overload: 120% for 1min 120% for 1min 120% for 1min 120% for 1min
Bypass Overload: 10x nominal current 10x nominal current 10x nominal current 10x nominal current
Output Current (A @ 208V): 28 42 56 83
Heat Rejection (max. BTUs): 4100 6100 8200 12200
Batteries
Backup Time (minutes)1: 11/39/60 7/22/35/55 15/24/38 8/12/21
Mechanical Specifications
Standard Cabinet
Dimensions (in): 32.8W x 62.4H x 35.5D 32.8W x 62.4H x 35.5D 32.8W x 62.4H x 35.5D 32.8W x 62.4H x 35.5D
(cm): 83.8W x 158.5H x 90.2D 83.8W x 158.5H x 90.2D 83.8W x 158.5H x 90.2D 83.8W x 158.5H x 90.2D
Weight2 (lb/kg): 2.065/0.94 2.065/0.94 2.065/0.94 2.065/0.94
Micro Cabinet3
Dimensions (in): 23W x 48.5H x 33.5D 23 W x 48.5 H x 33.5 D — —
(cm): 58.4W x 123.2H x 90.2D 58.4W x 123.2H x 90.2D — —
Weight (lb/kg): 2.065/0.94 2.065/0.94 — —
Auxiliary Cabinets
Maintenance Bypass Cabinet (in): 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D
(cm): 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D
Output Voltage Transformer (in): 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D
(cm): 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D
Distribution Cabinet (24 to 42 pole)(in): 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D 23W x 62.4H x 35.5D
(cm): 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D 58.4W x 158.5H x 90.2D
Weight (lb/kg): 780/353.8 780/353.8 780/353.8 780/353.8
Standards: UL 1778, cUL , FCC Class A parts, 15 sub part J Class A, IEC 1000 level 4, IEEE C62.41-B3, NEC, ISO 9001
1 11/7min battery times only applicable for micro cabinet. 2 Weight will vary based on battery runtime and input volt options.3 Micro Cabinet only available in 208/208V. External maintenance bypass distribution options not available with micro cabinet.
Three PhaseGalaxy 3000
50
Ind
oo
r S
olu
tio
ns
Alpha AC Catalogue 2008 For Prin50 50 7/30/2008 3:03:52 PM
Receptacle Information
Electrical receptacles, outlets, and wall sockets are used in a variety of residential, general-purpose, commercial, industrial, laboratory, and hospital applications. Several blade or pin types are available. Straight (non-locking) electrical receptacles are inserted at a right angle to the plane of the matching device face. By contrast, locking receptacles fix or lock a plug in place when the plug is inserted and then rotated. Electrical receptacles provide maximum voltage and maximum current ratings. Typically, devices are designed for either single-phase or three-phase power.
Below are diagrams to help identify plugs and receptacles for your electrical applications
X
G
X
GG
X
G
XX
YG
YG
X
Y Y Y Y
X
G
WY W Y
G
X
W/Y
X
G
X
GW/Y
NEMA CONFIGURATIONS FOR PLUGS AND RECEPTACLES
Non-Locking Plugs and Receptacles
Locking Plugs and Receptacles
15 Ampere 20 Ampere 30 Ampere 50 Ampere
15 Ampere 20 Ampere 30 Ampere 50 Ampere
Receptacle ReceptaclePlug Plug Receptacle Plug Receptacle Plug
Receptacle ReceptaclePlug Plug Receptacle Plug Receptacle Plug
125 V
250 V
125 V
250 V
125 /250 V
AlphaP/N
AlphaP/N
AlphaP/N
AlphaP/N
AlphaP/N
5-15R531-003-10531-002-10531-013-10
L6-15P530-202-10531-203-10
5-15P530-001-10
6-15R531-004-10
L5-15R531-201-10
L6-15R531-202-10
L6-20R531-205-10
L14-20R L14-20P530-205-10
L6-20P530-206-10
L6-30R531-207-10
L6-30P530-208-10
L5-15P530-201-10
L5-20R531-203-10
L5-20P530-204-10
L5-30R531-206-10
L5-30P530-207-10 531-208-10
531-209-10 530-210-10
530-209-10
6-15P530-002-10
6-20R531-008-10
6-20P530-004-10
6-30R531-010-10
6-30P530-006-10
6-50R531-012-10
6-50P530-008-10
5-20R531-006-10
5-20R531-005-10
6-20R531-007-10
5-20P530-003-10
5-30R531-009-10
5-30P530-005-10
5-50R531-011-10
5-50P530-007-10
For Canadian Customers Only
For Canadian Customers Only
EEMAC Configuration
EEMAC Configuration
(Not NEMA Config)
(Not NEMA Config)
Electrical Receptacles
51
Electrical R
eceptacles
Alpha AC Catalogue 2008 For Prin51 51 7/30/2008 3:03:53 PM
Building upon its suite of products, Alpha now offers a range of service solutions designed to meet your needs.
Extended Warranty:
Alpha extended warranties are available from the time of initial purchase through to the expiry of the product’s original warranty period. One or three year extensions offer all the terms and conditions of the original equipment warranty, for both the UPS and batteries in your system, with battery coverage offered on a prorated basis due to the nature of wear they sustain over time.
To purchase an extended warranty, or to make a claim against the initial product warranty, you will first need to ensure your products are registered. Additionally, product registration automatically extends your initial warranty period for an additional three months. Please note extended warranties are only available to the original registered purchaser. Register your products at www.alpha.com/productregistration
Field Service Contracts:
Enjoy convenience and peace-of-mind with an annual, prepaid, on site service plan and ensure all your service needs throughout the year are covered. Alpha offers two levels of service plans:
Alpha Basic Plan:A trained Alpha field service representative is available to you during regular business hours and will respond to service requests at your location by the next business day.
Alpha Emergency Plan:An Alpha field service representative is available to you during regular business hours and will respond to service requests at your location within four hours (not available in all areas).
Whether you choose the Alpha Basic Plan or the Alpha Emergency Plan you can rest assured you are covered. Alpha service plans ensure the people and parts will always be on hand. to provide the services you need when you need them most (not available in all areas). Both service plans include: • Unlimited technical phone support • All parts and labor • Travel expenses • All costs associated with equipment service
* battery replacement is offered on a prorated basis due to the nature of wear they sustain over time
Optional Coverage:
The purchase of an extended warranty or field service contract also enables you to benefit from valuable service options. Scheduled Preventative Maintenance ensures your backup solutions are always operating at optimum levels. An annual preventative maintenance visit from an Alpha representative includes: • Confirm proper installation of UPS • Clean or replace air filters • Test individual cells for voltage and impedance • Clean, inspect and test complete solution (inverters, transformers, switches and other components) • Perform thermal scan of solution using IR thermographs
Battery Renewal allows you to budget for battery replacement. When your batteries need replacing, Alpha will cover the cost.
Our Commitment:
Alpha Technologies is committed to providing service programs that ensure power integrity throughout the service life of you Alpha product.
Service
52
Ser
vice
Alpha AC Catalogue 2008 For Prin52 52 7/30/2008 3:03:53 PM
UninterruptiblePowerSupplySelectionGuide
To help us design an Uninterruptible Power Supply (UPS) solution for your specific application, please review the following questions prior
to contacting your Alpha representative.
TypeofApplication:
PBX, Cell Site, Server, Traffic, Parking, Security, Medical or other.
Environment:
Indoor: Controlled environment, air conditioned, dust free
Outdoor: Non-controlled environment
Minimum ambient temperature surrounding the UPS
Maximum ambient temperature surrounding the UPS
Geographic Location where the UPS is located (Country, City/Town)
Power Requirements:
Volt-amps (VA) or Watts required by load
Input voltage to UPS and Output voltage(s) to load
Frequency (Hz) 50 or 60
Backup Time Required:
The amount of time in hours or minutes the UPS will operate on batteries when the utility power fails
Mounting Configuration:
For Indoor Applications: Rack, Tower
For Outdoor Applications: Pole, Ground (Is a pedestal required?), or Wall
Configuration Requirements:
Input plug type or terminal block
Output receptacle types or terminal block
Accessories:
Bypass Switch (Auto/Manual), Ethernet/SNMP, Battery Heater Mats, Battery Management System
Warranty:
Is extended warranty required? Special servicing needs?
Quantities:
Number of units required and when
SelectionGuide
Alpha Technologies Due to continuing product development, Alpha reserves the right to change specifications without notice. Copyright © 2008 Alpha Technologies Inc. All Rights Reserved. Alpha is a registered trademark of Alpha Technologies. 048-160-10 (07/2008)
www.alpha.com
Argus TechnologiesUSA/Canada+ 1 604 436 5900
Alpha Technologies Europe Ltd.United Kingdom +44 1279 501110
Alpha Technologies GmbHGermany+ 49 9122 79889 0
AlphaTec Ltd.Republic of Cyprus+357 25 375675
Alphatec BalticsLithuania+370 5 213 8822
Alpha TechnologiesFrance+33 141 900 707
AlphaTEK oooRussia+7 495 916 1854
Alpha TechnologiesPR China+852 2736 8663
Alpha Technologies Ltd.4084 McConnell CourtBurnaby BC V5A 3N7Canada+ 1 800 667 8743 (toll free)+ 1 604 430 1476 (Canada)+ 1 360 647 2360 (USA)
Visit www.alpha.com for additional information.
member of The Group™
top related