M4AH4E26B1A00AA SUBMITTAL TAG: _________________________________ 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA Ameristar UPFLOW UNIT SHOWN; UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT, OR LEFT AIR SUPPLY. NOTE: 25” CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR FILTER AND COIL MAINTENANCE. SUPPLY AIR FLANGES ARE PROVIDED FOR FIELD INSTALLATION ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE HIGH VOLTAGE CONNECTION 7/8”, 1-3/8”, 1-3/4” DIA KNOCK OUTS LOW VOLTAGE CONNECTION BREAKER SWITCH (FOR ELECTRIC HEATER ONLY) VAPOR LINE CONNECTION COPPER (SWEAT) LIQUID LINE CONNECTION COPPER (SWEAT) AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT) AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT) PRIMARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT) H D M4AH4E26B1A00AA Model H W D A 1050 (41-3/ 8 ) 460 (18-1/8) 520 (20-1/2) 406 (16) NOTE: All dimensions are in mm/inches. 10 5 16 W A

Upload: others

Post on 31-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Ameristar M4AH4E26B1A00AA · 2018. 7. 26. · m4ah4e26b1a00aa tag: _____ submittal 2.0 ton multi-position air handler m4ah4e26b1a00aa ameristar upflow unit shown; unit may be installed

M4AH4E26B1A00AA

SUBMITTAL TAG: _________________________________

2.0 Ton Multi-position Air HandlerM4AH4E26B1A00AA

Ameristar

UPFLOW UNIT SHOWN;UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT, OR LEFT AIR SUPPLY.

NOTE: 25” CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR FILTER AND COIL MAINTENANCE.

SUPPLY AIR

FLANGES ARE PROVIDED FOR FIELD INSTALLATION

ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE

HIGH VOLTAGE CONNECTION 7/8”, 1-3/8”, 1-3/4” DIA KNOCK OUTS

LOW VOLTAGE CONNECTION

BREAKER SWITCH (FOR ELECTRIC HEATER ONLY)

VAPOR LINE CONNECTION COPPER (SWEAT)

LIQUID LINE CONNECTION COPPER (SWEAT)

AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

PRIMARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

H

D

M4AH4E26B1A00AA

Model H W D A

1050 (41-3/ 8) 460 (18-1/8) 520 (20-1/2) 406 (16)

NOTE: All dimensions are in mm/inches.

10 5 16 WA

Page 2: Ameristar M4AH4E26B1A00AA · 2018. 7. 26. · m4ah4e26b1a00aa tag: _____ submittal 2.0 ton multi-position air handler m4ah4e26b1a00aa ameristar upflow unit shown; unit may be installed

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONSMODEL M4AH4E26B1A00AARATED VOLTS/PH/HZ. 208-230/1/60RATINGS INDOOR COIL — Type Plate FinRows — F.P.I. 4 - 17Face Area (sq. ft.) 4.01Tube Size (in.) 9/32Refrigerant Control OrificeDrain Conn. Size (in.) 3/4 NPTDUCT CONNECTIONS See Outline DrawingINDOOR FAN — Type CentrifugalDiameter-Width (In.) 10-5/8 X 8-1/8No. Used 1Drive - No. Speeds Direct - 5CFM vs. in. w.g. See Fan Performance TableNo. Motors — H.P. 1 - 1/3Motor Speed R.P.M. 1050Volts/Ph/Hz 208-230/1/60F.L. Amps 2.6FILTERFilter Furnished? NoType Recommended ThrowawayNo.-Size-Thickness 1 - 16 X 20 - 1 in.REFRIGERANT R-410ARef. Line Connections BrazedCoupling or Conn. Size — in. Gas 3/4Coupling or Conn. Size — in. Liq. 3/8DIMENSIONS H x W x DCrated (In.)

41-3/8 x 18-1/8 x 20-1/2Uncrated 42-7/10x 21 x 24-1/6

WEIGHTShipping (Lbs.) / Net (Lbs.) 114/101

See O.D. Specifications

590

883

1103

544

842

1073

511 447

796

1036

404

758

998

345

717

967

311

681

934

Heater KitModel Used

MAYHTR1A05BKR*

Electric Heat (kW)

Min. Circuit Ampacity Max. Fuse or Breaker(HACR) Ampacity

240V 208V 208V240V

MAYHTR1A08BKR*

MAYHTR1A10BKR*

5

7.5

10

29.4

42.4

55.4

25.9

37.2

55.4

30

45

60

30

40

50

Note: Factory set at Medium High Speed.

M4AH4E26B1A00AAMotor Speed

AIR FLOW PERFORMANCE

External Static Pressure-Inches W.C. (kPa)

CFM

CFM

CFM

0(0)

1

45

0.1(.02) 0.2(.05) 0.3(.07) 0.4(.10) 0.5( .12) 0.6(.15)

896

0.7(.17)

855

0.8(.20)

814

273 239

642 599 524

23 CFM

CFM 681 633 591 535 490 446 388 354 313788 736 687 648 597 558 511 473 429

Minimum Heating Blower Speed

Without HP With HP

Low

Low

Low

Low

Low

Low

Page 3: Ameristar M4AH4E26B1A00AA · 2018. 7. 26. · m4ah4e26b1a00aa tag: _____ submittal 2.0 ton multi-position air handler m4ah4e26b1a00aa ameristar upflow unit shown; unit may be installed

The manufacturer has a policy of continuous product and product data improve-ment and it reserves the right to change design and specification without notice.

Mechanical Specifications

Ameristar

• Unique Cabinet Design- Metal shell and glass cotton thermal insulation layer• Multi-Position UP/Down Flow Horizontal Left /Right• Braze in Refrigerant Connection• Primary/Secondary Condensate Connections• Blower with Integrated Slide Deck for Easy Removal• Inner-groove aluminum tube and high-efficiency aluminum fin Coil with Integrated Slide Deck for Easy Removal• More auxiliary Electric Heaters optional• ECM 5 Speed Motor • High Efficiency• Integrated Horizontal Drain pans and metal Vertical Drain• Fused 24V Power• 5-Year Warranty.• 10-Year Warranty Registered.• Warranty Mirrors Outdoor.• Optional extended warranty available.

Page 4: Ameristar M4AH4E26B1A00AA · 2018. 7. 26. · m4ah4e26b1a00aa tag: _____ submittal 2.0 ton multi-position air handler m4ah4e26b1a00aa ameristar upflow unit shown; unit may be installed

M4AH4E37B1B00AA

SUBMITTAL TAG: _________________________________

3.0 Ton Multi-position Air HandlerM4AH4E37B1B00AA

Ameristar

UPFLOW UNIT SHOWN;UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT, OR LEFT AIR SUPPLY.

NOTE: 25” CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR FILTER AND COIL MAINTENANCE.

SUPPLY AIR

FLANGES ARE PROVIDED FOR FIELD INSTALLATION

ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE

HIGH VOLTAGE CONNECTION 7/8”, 1-3/8”, 1-3/4” DIA KNOCK OUTS

LOW VOLTAGE CONNECTION

BREAKER SWITCH (FOR ELECTRIC HEATER ONLY)

VAPOR LINE CONNECTION COPPER (SWEAT)

LIQUID LINE CONNECTION COPPER (SWEAT)

AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

PRIMARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

H

D

M4AH4E37B1B00AA

Model H W D A

1180 (46-1/ 2) 500 (19-5/8) 550 (21-5/8) 456 (18)

NOTE: All dimensions are in mm/inches.

10 5 16 WA

Page 5: Ameristar M4AH4E26B1A00AA · 2018. 7. 26. · m4ah4e26b1a00aa tag: _____ submittal 2.0 ton multi-position air handler m4ah4e26b1a00aa ameristar upflow unit shown; unit may be installed

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONSMODEL M4AH4E37B1B00AARATED VOLTS/PH/HZ. 208-230/1/60RATINGS INDOOR COIL — Type Plate FinRows — F.P.I. 4 - 17Face Area (sq. ft.) 4.01Tube Size (in.) 9/32Refrigerant Control OrificeDrain Conn. Size (in.) 3/4 NPTDUCT CONNECTIONS See Outline DrawingINDOOR FAN — Type CentrifugalDiameter-Width (In.) 10-5/8 X 10-3/4No. Used 1Drive - No. Speeds Direct - 5CFM vs. in. w.g. See Fan Performance TableNo. Motors — H.P. 1 - 1/2Motor Speed R.P.M. 1050Volts/Ph/Hz 208-230/1/60F.L. Amps 3.0FILTERFilter Furnished? NoType Recommended ThrowawayNo.-Size-Thickness 1 - 18 X 20 - 1 in.REFRIGERANT R-410ARef. Line Connections BrazedCoupling or Conn. Size — in. Gas 3/4Coupling or Conn. Size — in. Liq. 3/8DIMENSIONS H x W x DCrated (In.)

46 -1/2 x19-5/8 x 21-5/8Uncrated 47-4/5 x 22-3/5 x 25-7/10

WEIGHTShipping (Lbs.) / Net (Lbs.) 141/125

See O.D. Specifications

Heater KitModel Used

MAYHTR1A05BKR*

Electric Heat (kW)

Min. Circuit Ampacity Max. Fuse or Breaker(HACR) Ampacity

240V 208V 208V240V

MAYHTR1A08BKR*

MAYHTR1A10BKR*

5

7.5

10

29.9

42.9

55.9

26.4

37.7

49

30

45

60

30

40

50

Note: Factory set at Medium High Speed.

MAYHTR1A15BKR* 15 55.9/26.1 49/22.6 60/30 50/25

MAYHTR1A20BKR* 20 55.9/52.1 49/45.2 60/60 50/50

6466947688258939921052111411613664094905446306948109021026CFM

CFM32

893892914

203259

1029

0.8(.20)

1088

0.7(.17)

1150

0.6(.15)0.5( .12)0.4(.10)0.3(.07)0.2(.05)0.1(.02)

54

1

0(0)

CFM

CFM

CFM

.C. (kPa)External Static Pressure-Inches W

AIR FLOW PERFORMANCE

SpeedMotor M4AH4E37B1B00AA

1243

969

301

1302

1078

360

1348

1142

405

1396

1186

511603

1442

1244

752

1491

1287

898

Minimum Heating Blower Speed

Without HP With HP

Low Low

Low Low

Low Low

Low

Low

Low

Low

Page 6: Ameristar M4AH4E26B1A00AA · 2018. 7. 26. · m4ah4e26b1a00aa tag: _____ submittal 2.0 ton multi-position air handler m4ah4e26b1a00aa ameristar upflow unit shown; unit may be installed

The manufacturer has a policy of continuous product and product data improve-ment and it reserves the right to change design and specification without notice.

Mechanical Specifications

Ameristar

• Unique Cabinet Design- Metal shell and glass cotton thermal insulation layer• Multi-Position UP/Down Flow Horizontal Left /Right• Braze in Refrigerant Connection• Primary/Secondary Condensate Connections• Blower with Integrated Slide Deck for Easy Removal• Inner-groove aluminum tube and high-efficiency aluminum fin Coil with Integrated Slide Deck for Easy Removal• More auxiliary Electric Heaters optional• ECM 5 Speed Motor • High Efficiency• Integrated Horizontal Drain pans and metal Vertical Drain• Fused 24V Power• 5-Year Warranty.• 10-Year Warranty Registered.• Warranty Mirrors Outdoor.• Optional extended warranty available.

Page 7: Ameristar M4AH4E26B1A00AA · 2018. 7. 26. · m4ah4e26b1a00aa tag: _____ submittal 2.0 ton multi-position air handler m4ah4e26b1a00aa ameristar upflow unit shown; unit may be installed

M4AH4E61B1C00AA

SUBMITTAL TAG: _________________________________

5.0 Ton Multi-position Air HandlerM4AH4E61B1C00AA

Ameristar

UPFLOW UNIT SHOWN;UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT, OR LEFT AIR SUPPLY.

NOTE: 25” CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR FILTER AND COIL MAINTENANCE.

SUPPLY AIR

FLANGES ARE PROVIDED FOR FIELD INSTALLATION

ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE

HIGH VOLTAGE CONNECTION 7/8”, 1-3/8”, 1-3/4” DIA KNOCK OUTS

LOW VOLTAGE CONNECTION

BREAKER SWITCH (FOR ELECTRIC HEATER ONLY)

VAPOR LINE CONNECTION COPPER (SWEAT)

LIQUID LINE CONNECTION COPPER (SWEAT)

AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

AUXILIARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

PRIMARY DRAIN CONNECTION 3/4” FEMALE PIPE THREAD (NPT)

H

D

M4AH4E61B1C00AA

Model H W D A

1385 (54-1/ 2) 560 (22) 610 (24) 496 (19-1/2)

NOTE: All dimensions are in mm/inches.

10 5 16 WA

Page 8: Ameristar M4AH4E26B1A00AA · 2018. 7. 26. · m4ah4e26b1a00aa tag: _____ submittal 2.0 ton multi-position air handler m4ah4e26b1a00aa ameristar upflow unit shown; unit may be installed

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONSMODEL M4AH4E61B1C00AARATED VOLTS/PH/HZ. 208-230/1/60RATINGS INDOOR COIL — Type Plate FinRows — F.P.I. 4 - 17Face Area (sq. ft.) 6.00Tube Size (in.) 9/32Refrigerant Control OrificeDrain Conn. Size (in.) 3/4 NPTDUCT CONNECTIONS See Outline DrawingINDOOR FAN — Type CentrifugalDiameter-Width (In.) 10-5/8 X 10-3/4No. Used 1Drive - No. Speeds Direct - 5CFM vs. in. w.g. See Fan Performance TableNo. Motors — H.P. 1 - 3/4Motor Speed R.P.M. 1050Volts/Ph/Hz 208-230/1/60F.L. Amps 4.5FILTERFilter Furnished? NoType Recommended ThrowawayNo.-Size-Thickness 1 - 20 X 22 - 1 in.REFRIGERANT R-410ARef. Line Connections BrazedCoupling or Conn. Size — in. Gas 7/8Coupling or Conn. Size — in. Liq. 3/8DIMENSIONS H x W x DCrated (In.)

54-1/2 x22 x 24Uncrated 55-4/5 x 25 x 27-7/10

WEIGHTShipping (Lbs.) / Net (Lbs.) 177/159

See O.D. Specifications

Heater KitModel Used

MAYHTR1A05BKR*

Electric Heat (kW)

Min. Circuit Ampacity Max. Fuse or Breaker(HACR) Ampacity

240V 208V 208V240V

MAYHTR1A08BKR*

MAYHTR1A10BKR*

5

7.5

10

31.8

44.8

57.8

28.3

39.6

50.9

40

45

60

30

40

60

Note: Factory set at Medium High Speed.

MAYHTR1A15BKR* 15 57.8/26.1 50.9/22.6 60/30 60/25

MAYHTR1A20BKR* 20 57.8/52.1 50.9/45.2 60/60 60/50

1344

1875

2021

1284

1822

1967

1226 1151

1774

1924

1076

1729

1879

946

1677

1828

904

1629

1785

M4AH4E61B1C00AAMotor Speed

AIR FLOW PERFORMANCE

External Static Pressure-Inches W.C. (kPa)

CFM

CFM

CFM

0(0)

1

45

0.1(.02) 0.2(.05) 0.3(.07) 0.4(.10) 0.5( .12) 0.6(.15)

1742

0.7(.17)

1694

0.8(.20)

1641

893 869

1581 1533 1473

23 CFM

CFM 1531 1477 1418 1366 1299 1239 1138 1064 10011647 1592 1538 1490 1436 1378 1315 1215 1140

Minimum Heating Blower Speed

Without HP With HP

Low Low

Low Low

Low Low

Low Low

Low Low

Page 9: Ameristar M4AH4E26B1A00AA · 2018. 7. 26. · m4ah4e26b1a00aa tag: _____ submittal 2.0 ton multi-position air handler m4ah4e26b1a00aa ameristar upflow unit shown; unit may be installed

The manufacturer has a policy of continuous product and product data improve-ment and it reserves the right to change design and specification without notice.

Mechanical Specifications

Ameristar

• Unique Cabinet Design- Metal shell and glass cotton thermal insulation layer• Multi-Position UP/Down Flow Horizontal Left /Right• Braze in Refrigerant Connection• Primary/Secondary Condensate Connections• Blower with Integrated Slide Deck for Easy Removal• Inner-groove aluminum tube and high-efficiency aluminum fin Coil with Integrated Slide Deck for Easy Removal• More auxiliary Electric Heaters optional• ECM 5 Speed Motor • High Efficiency• Integrated Horizontal Drain pans and metal Vertical Drain• Fused 24V Power• 5-Year Warranty.• 10-Year Warranty Registered.• Warranty Mirrors Outdoor.• Optional extended warranty available.