acr - tepse · all acr talos copper tubes meet ped 97/23 requirements and the strict german...

20
ACR C O P P E R T U B E S REFRIGERATION - AIR CONDITIONING

Upload: others

Post on 17-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

ACR

C O P P E R T U B E S

R E F R I G E R A T I O N - A I R C O N D I T I O N I N G

Page 2: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

Certified ISO 9001 : 2000 by

A U S T R I A

H E L L A S

AENOR

Certificado

Producto

AENOR

Certificado

Producto

HALCOR is a large-scale modern industrial company with oversixty years of experience in metal processing. It holds asignificant position in European and global markets and hasfour modern plants; three in Greece and one in Bulgaria.

The company is dedicated to achieving high quality. It hasISO 9001:2000 certification, uses state-of-the-art technologyand employs highly skilled personnel. Substantial, continualinvestment in research and know-how allows the company tocreate innovative new products, which supports its aim of beinga market leader.

At the same time, HALCOR is committed to sustaineddevelopment and environmental protection. As such, itsproduction processes are regulated by an ISO 14001:2004certified Environmental Management System.

Aiming at the total satisfaction of all of its customers' needs,the company focuses on responding reliably and rapidly todemand. It provides exceptional support for its products,which are distributed to more than fifty countries worldwide.HALCOR combines size, strength and technology to achieveits overall vision of putting metals at man's disposal.

Page 3: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

3

Page 4: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

ACR

C O P P E R T U B E S

24

The unique properties of high purity copper, make ACR TALOScopper tubes, indispensable for refrigeration installations.

As a result of which ACR TALOS copper tubes create highthermodynamic and operational requirement with ease ofinstallation, all of which result in an overall cost reduction.

®

®

High thermal conductivity.Invariable mechanical properties covering an extensivetemperature range.Chemically inert compared to refrigerants (R134A,R404A, R407C, R410A).High internal cheek purity.Smoothly internal surface enhance flow rate.Excellent weldability, either by hard or half had welding.Excellent old forming ability.The same installation may be used either for refrigerationor heating.

REFRIGERATIONAIR CONDITIONING

Advantages of ACR TALOS copper tubes®

Page 5: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

5

SPECIFICATIONS

EN 12735 Part 1-2, ASTM B280/B68/B743, JIS H3300.All ACR TALOS copper tubes meet PED 97/23 requirements and the strictGerman regulation AD 2000/W6 on pressure tanks.

®

QUALITY MARKS

AENOR, TUV.

MECHANICAL PROPERTIES

� 40%

Yieldin 0,2%

strength

� 200 N/mm2 � 60 N/mm2

Tensile strength/mm 2

Elongation5%

PANCAKES

Copper tubeexternal diameter

Copper tubeexternal diameter

Copper tubewall thickness

Copper tubewall thickness

Weight

Weight

Maximum permittedworking pressure

Maximum permittedworking pressure

bar

bar

inchmm

inchmm

inchmm

inchmm

Kgr/m

Kgr/m

STANDARD DIMENSION ACCORDING TO US STANDARDS (ASTM)

1/4

6,35

0,80

0,124

128

0,032

3/16

4,76

0,800,032

0,089

180

0,800,032

0,160

100

5/16

7,94

3/8

9,52

0,800,032

0,195

82

1/2

12,70

0,800,032

0,266

60

5/8

15,88

1,000,039

0,416

60

3/4

19,05

1,000,039

0,505

49

1,250,049

0,733

86

7/8

22,23

STRAIGHT LENGTHS (4 OR 5 METERS)

1/2

12,70

0,80

0,032

0,266

97

3/8

9,52

0,80

0,032

0,195

133

1,00

0,039

0,416

97

5/8

15,88

3/4

19,5

1,00

0,039

0,505

80

7/8

22,23

1,25

0,049

0,733

86

1 1/8

28,58

1,25

0,049

0,955

66

0,049

1,25

34,93

1 3/8

1,177

54

Customised dimensions are manufactured upon request.

0,049

1 5/8

41,28

1,25

1,399

45

2 1/8

53,98

0,065

1,65

2,414

46

2 5/8

66,68

0,079

2,00

3,616

45

3 1/8

79,38

0,098

2,50

5,373

47

3 5/8

92,08

0,098

2,50

6,261

40

Copper phosphorus deoxidised (DHP-Cu), minimum 99.9% Cu and P = 0.015% - 0.040%.

PACKAGING

pcs.

mm

Kgr/m

PANCAKES

Customised dimensions are manufactured upon request.

STANDARD DIMENSIONS ACCORDING TO EUROPEAN STANDARDS (EN)

28 x 1.50Dimensions

Pancakes per carton

Weight 1,111

6 x 1 8 x 1 10 x 1 12 x 1 15 x 1 18 x 1 22 x 1

0,140 0,196 0,252 0,308 0,391 0,475 0,587

2 x 35m 1 x 35m 1 x 35m 1 x 35m 1 x 25m 1 x 25m 1 x 25m 1 x 25m

mm

Kgr/m

STRAIGHT LENGTHS (5 METERS)

Dimensions

5 meter lengths per carton

Weight

88.9x2.06.0x1.0 8.0x1.0 10.0x1.0 12.0x1.0 15.0x1.0 18.0x1.0 22.0x1.0 28.0x1.5 35.0x1.5 42.0x1.5 54.0x2.0 64.0x2.0 76.1x2.0

4.860.140 0.196 0.252 0.308 0.391 0.475 0.587 1.110 1.410 1.700 2.91 3.47 4.14

140 40 24 10 12 10 10 10 5 5 4 4 2

Straight lengthsPancakes

, in bundles (hard copper tubes) and in wooden boxes (soft copper tubes)-PNC in shrink-wrapped individual plastic bags. Depending on market

requirements, they can be placed in cardboard boxes and pallets.

MATERIAL

pcs.

Page 6: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

6

ACR

C O P P E R T U B E S

REFRIGERATIONAIR CONDITIONING

Spools with a “central” reel are especially prepared so that theyunwind from the center.They provide significant advantages to the user, such asreduction in packaging materials, unwinding “on the pallet”,greater weights per spool and, therefore, longer production.ACR TALOS copper tubes do not require special unwindingequipment; they have lower handling costs, reducing machinedowntime and enhanced performance.

®

Spools with a “central” reel (CD coils)

ACR TALOS copper tubes for refrigeration units are available inthe following types:

®

ACR TALOS copper tubes are available in spools (LWC)with or without central support (hard cardboard).Spool sides may be delivered protected by “flanges”of reinforced corrugated cardboard.

®

Spools (LWC)

Page 7: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

7

3000

2000

100

6 222018161412108

150

200

300

400

500

600

800

1000

15000.30

0.35

0.40

0.50

0.60

0.70

0.80

1.00

1.251.50

1.752.00

External diameter, mm

TUBE LENGTH IN METERS(BASED ON LWC SPOOLS OF 130 KGS)

SPOOL (LWC) DIMENSIONS

200 or280 mm

Maximum 1040 mm

610 mm

Spool weight: 90 to 230 kg(Spools of greater weight are available upon request)

200 to340 mm

AVAILABLE DIMENSIONS

0,0120,30

0,0110,28

0,0140,35

0,0160,41

0,0200,51

0,0180,45

0,0250,635

0,0280,71

5/16

3/8

1/2

5/8

7,94

9,52

12,70

15,87

Recommended dimensions for LWC spools

(inch)(mm)

ThicknessExternaldiameter

(inch) (mm)

Wall thickness in mm

Page 8: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

8

Page 9: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

CW024A EN 1173

SF-Cu DIN1787

C-106 BS 2871 3 TABLE 1

C12200 ASTM B 743

PART

C1220 JIS H 3300

MATERIAL SPECIFICATIONS

TEMPER: Light or fully annealed.

9

HALCOR has developed its own standard with regard tothe design of new high thermal performance tubes withinner grooves. With these tubes, the thermal performanceof refrigeration units is improved, enabling the reduction ofthe size of these units, whilst reducing the quantity of therefrigeration mixture required.

Inner grooved tubes

MATERIAL

Copper phosphorus deoxidised (DHP-Cu), minimum99.9% Cu and P = 0.015% - 0.040%.

HEAT EXCHANGERS

Page 10: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

10

DIMENSIONS

A-1

A-2

B-2

B-3

B-6

B-10

B-15

B-21

B-22

B-25

C-1

C-2

C-3

C-15

Groovetype

/HALCORCode

9.52 x 0.35

9.52 x 0.41

7.94 x 0.30

8.00 x 0.30

9.52 x 0.36

9.52 x 0.35

7.00 x 0.30

12.70 x 0.45

12.70 x 0.45

12.00 x 0.45

9.52 x 0.33

9.52 x 0.39

8.00 x 0.32

7.00 x 0.32

9.52 ± 0.05

9.52 ± 0.05

7.94 ± 0.05

8.00 ± 0.05

9.52 ± 0.05

9.52 ± 0.05

7.00 ± 0.05

12.70 ± 0.05

12.70 ± 0.05

12.00 ± 0.05

9.52 ± 0.05

9.52 ± 0.05

8.00 ± 0.05

7.00 ± 0.05

Externaldiameter

(mm)

8.66 ± 0.05

8.54 ± 0.05

7.06 ± 0.03

7.12 ± 0.03

8.52 ± 0.03

8.66 ± 0.03

6.14 ± 0.03

11.48

11.48

10.80

8.62

± 0.05

± 0.05

± 0.05

± 0.05

8.40 ± 0.05

7.04 ± 0.03

6.02 ± 0.03

Internaldiameter

(mm)

0.28 ± 0.03

0.34 ± 0.03

0.26 ± 0.03

0.26 ± 0.03

0.30 ± 0.03

0.28 ± 0.03

0.25 ± 0.03

0.36

0.36

0.35

0.27

± 0.03

± 0.03

± 0.03

± 0.03

0.31 ± 0.03

0.26 ± 0.03

0.25 ± 0.02

Bottomwall

(mm)

0.15 ± 0.02

0.15 ± 0.02

0.18 ± 0.02

0.18 ± 0.03

0.20 ± 0.02

0.15 ± 0.02

0.18 ± 0.02

0.25

0.25

0.25

0.18

± 0.02

± 0.02

± 0.02

± 0.02

0.25 ± 0.02

0.22 ± 0.02

0.24 ± 0.02

Groovedepth

(mm)

0.43 ± 0.05

0.49 ± 0.05

0.44 ± 0.05

0.44 ± 0.05

0.50 ± 0.05

0.43 ± 0.05

0.43 ± 0.05

0.61

0.61

0.60

0.45

± 0.05

± 0.05

± 0.05

± 0.05

0.56 ± 0.05

0.48 ± 0.05

0.49 ± 0.04

Total wallthickness

(mm)

65

65

50

50

60

60

50

70

75

70

70

65

65

55

Numberof

grooves

25 ± 2

25 ±

18 ±

18 ±

18 ±

18 ±

18 ±

18 ± 2

18 ± 2

18 ± 2

25 ± 2

25 ± 2

35 ± 1

27 ± 1

2

2

2

2

2

2

90

85

40

40

53

53

40

58

58

55

25

25

15

15

Topangle

(degrees)

94 ± 2

104 ±

64 ±

65 ±

93 ±

89 ±

57 ±

± 2

± 2

± 2

± 2

99 ± 2

69 ± 2

59 ± 2

2

2

2

2

2

2

155

155

145

84

Unitweight

(gr/m)

Nominalsize

Leadangle

(degrees)

Page 11: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

11

Page 12: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

12

Page 13: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

13

WATER SUPPLYHEATINGAIR CONDITIONINGREFRIGERATIONSOLAR SYSTEMSINDUSTRIAL NETWORKS

TALOS ECUTHERM copper tubes are insulated with highquality extruded polyethylene foam (PDF), structured inclosed-type microcells. The insulation is covered externally bya protective polyethylene sheath of three different types.TALOS ECUTHERM copper tubes are available in 25 and50 m coils, in two types of insulation material of differentthickness, depending on the requirements of the construction.- TALOS ECUTHERM ΡΕ-Χ. Insulation with low-density cross-linked PEF without HCFC and fibrous materials, thickness:6, 9 and 9 mm.- TALOS ECUTHERM ΡΕ. Insulation with low-density PEFwithout HCFC and fibrous materials, thickness: 6, 9 and13 mm.The closed-type microcells, combined with the protectivesheath, form a solid resistance barrier, that provides all the

TM

TM

TM

TM

Advanced technology that saves energy andprotects the environment

High performance technological product

necessary technical properties for any kind of application,such as heating, air conditioning, refrigeration and otherplumbing applications.TALOS ECUTHERM copper tubes, are manufacturedaccording to the specifications applicable in most EUcountries as well as other international specifications interms of insulation, fire resistance, technical and chemicalproperties.TALOS ECUTHERM copper tubes have a low λ coefficient,which determines thermal conductivity and an exceptional μcoefficient, which determines resistance to vapour and waterdiffusion.TALOS ECUTHERM copper tubes meet the requirements ofthe Uniform European Standard EN 14313 on PEF insulationmaterials for building and industrial plumbing installations.

TM

TM

TM

Significant and continuous energy savings.Safe network operation.Reduction of installation time.High resistance to mechanical stress.Easy of formability.External or embedded installations.Resistance to extreme atmospheric conditions.30-year guarantee, covering the quality of manifactureof the copper tube.

TALOS ECUTHERM pre-insulated copper tubes areadvanced technology products, of high added value andsignificantly superior in effectiveness, compared toconventional insulation methods. The unique advantagesoffered by the TALOS ECUTHERM copper tubes, such ascopper resistance and durability, coupled with highperformance pre-insulation (Engineering Foams), result insignificant energy savings. With a significantly competitivemarket price and low installation cost, TALOS ECUTHERMcopper tubes are easily, the ideal choice for every modernapplication.

TM

TM

TM

Page 14: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

14

COPPER TUBE

INSULATION MATERIAL

PROTECTIVE SHEATHING

TALOS copper tubes are manufactured according to (a) theUniform European Standard EN 1057 for use in plumbinginstallations and (b) the Uniform European Standard EN 12735-1for use in air conditioning and refrigeration installations.TALOS copper tubes meet the current requirements, imposedby the new green refrigerants (R 410-A, etc.), adopted by majorrefrigeration and air conditioning unit manufacturers, both inGreece and abroad.TALOS copper tubes have been awarded most majorinternational quality marks and are exported to more than50 countries, throughout the world. TALOS copper tubes,with their high quality of manufacture, provide:

®

®

®

®

Unlimited lifetime.Resistance to pressure, temperature and fire.Complete network impermeability.Hygienic, safe, and bacteria-free potable water.Quality and reliability of installation.Versatile applications.Comprehensive range sizes.Style and space saving.Low thermal expansion.

Reliability that only TALOScopper tubes can provide

®

Page 15: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

15

Soft R-220 >220 >40

Temper ELOT EN 1057Classification

Tensile strengthΝ/mm2

Minimum elongationΑ5%

Copper tubeexternal diameter

Copper tubeexternal diameter

Copper tubewall thickness

Copper tubewall thickness

Overall external diameterwith 9mm thick insulation

Overall external diameterwith 9mm thick insulation

Maximum permittedworking pressure

Maximum permittedworking pressure

bar

mm

mm

mm

0,80

6

24

137

0,80

8

26

99

0,80

10

28

77

1,00

12

30

104

1,00

15

33

85

1,00

16

34

80

1,00

18

36

70

1,00

22

40

57

1/4

6,35

0,80

24,35

186

3/16

4,76

0,80

22,76

169

0,80

25,94

100

5/16

7,94

3/8

9,52

0,80

27,52

84

1/2

12,70

0,80

30,70

63

5/8

15,87

1,00

33,87

62

37,05

19,05

3/4

1,00

51

1,14

40,23

48

7/8

22,23

STANDARD DIMENSIONS ACCORDING TO EN 12735-1

inch

mm

mm

mm

bar

TALOS ECUTHERM copper tubes, are also available in straight lengths of 5m, with half hardcopper tube, upon request.

TM

WATER PIPES:REFRIGERATION PIPES:

EN 1057: 1996EN 12735-1: 2001

WATER PIPES:REFRIGERATION PIPES:

RAL/DVGW, BSI, AFNOR, AENOR, NSF, CSTB (Avis Technique)AENOR, TUV.

Values are listed, as obtained under standard laboratory conditions and may be amended, withoutprior notice.

MATERIAL PEF ÑÅ

30-31 Kg/m3

0,039 W/m.K

�12.000

-35 C to +95 Cο ο

CL1, DIN 4102 B2

Very good

60%

ÑÅ-×

DIN 4102 B2, BS 476, M1

30-33 Kg/m3

0,035 W/m.K

-80 C to +110 Cο ο

Very good

�12.000

60%

Copper phosphorus deoxidised (DHP-Cu), minimum 99.9% Cu and P = 0.015% - 0.040%

COPPER TUBE MATERIAL

MECHANICAL PROPERTIES

SPECIFICATIONS

QUALITY MARKS

INSULATION TECHNICAL PROPERTIES

STANDARD DIMENSIONS ACCORDING TO EN 1057

DENSITY ACCORDING TO DIN 53420ASTM D 1667

THERMAL CONDUCTIVITY COEFFICIENT (λ)ACCORDING TO ASTM C 335

VAPOUR-WATER DIFFUSSION RESISTANCECOEFFICIENT (μ) ACCORDING TO DIN 52615

WORKING TEMPERATURE

FIRE RESISTANCE

RESISTANCE TO CHEMICAL AGENTSACCORDING TO ASTM 543-56 T

SOUND ABSORPTION ACCORDING TODIN 4109 300-2500Hz

Page 16: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

16

1/2 inch - 12,7 mm 5/8 inch - 15,88 mm

6

6

6

6

6

9

9

6

6

9

9

9

9

13

9

9

9

13

13

13

13

6

6

6

6

6

9

9

6

6

9

9

9

9

13

9

9

9

13

13

13

13

6

66

66

66

66

96

96

6

6

9

9

9

9

13

6

6

6

6

6

6

9

6

6

6

6

9

9

9

6

9

9

9

9

13

13

6

66

66

66

96

96

99

6

6

9

9

9

13

13

6

6

6

6

6

6

9

6

6

6

6

9

9

9

6

9

9

9

13

13

13

6

6

6

6

6

6

9

6

6

6

9

9

9

9

9

9

9

9

13

13

13

6

6

6

6

6

9

9

6

6

9

9

9

9

13

9

9

9

9

13

13

13

TEMPE-RATUREINSIDE

THE TUBE( C)ο

AMBIENT TEMPERATURE ( C) AND RELATIVE HUMIDITY (%)ο

50% 60% 70% 50% 60% 70% 50% 60% 70% 50% 60% 70%

25 Cο

+15

-20

+10

-10

+5

-5

0

30 Cο 35 Cο 40 Cο

INSULATION THICKNESS (mm)

TYPES OF EXTERIOR PROTECTIVE SHEATHING

MARKING

LengthIndication

Producer Brandname

InsulationThickness

48m HALCOR S.A. TALOS ECUTHERM 12 X1,00 PE Cl1 9 II 05TM

Insulationmaterial

Quarterand year

of productionCopper tubedimensions

Non-flammablespecification

t =2 +te0,2 ë (ti-te)� �

(d+2s) L� �

(d+2s)

d

Air conditioning and refrigeration units, operate intemperatures lower than ambient temperature;therefore, this difference must be compensated bythe appropriate insulation thickness, to preventvapour condensation. The thickness of theinsulation (with reference to Mollier's diagram), iscalculated taking into consideration thetemperature of the fluid (or gas) inside the pipes,ambient temperature and the relative humidity ofthe air.

TALOS ECUTHERM 1/2” AND 5/8”INDICATIVE CALCULATION OFINSULATION THICKNESS

TM

SURFACE TEMPERATURE CALCULATION FORMULA

Page 17: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

1/4 + 3/8

1/4 + 1/2

1/4 + 5/8

1/4 + 3/4

3/8 + 1/2

3/8 + 5/8

3/8 + 3/4

1/2 + 3/4

PAIR DIAMETERS

COPPER TUBE

INSULATION

PROTECTIVE

SHEATHING

A C RC O P P E R T U B E S

ECUTHERM 2TM

REFRIGERATIONAIR CONDITIONING

17

ACR TALOS ECUTHERM 2 copper tubes are manufactured inpairs, firmly connected along their entire length, and in eightstandard size combinations which cover sufficiently the usualconnectivity requirements of any refrigeration or air conditioningunit.ACR TALOS ECUTHERM 2 copper tube pairs, form a singleunit which is installed easily and fast, ensuring professionalresults.

TM

TM

ACR TALOS ECUTHERM 2 pre-insulated copper tubes,manufactured by HALCOR are an innovation that ensuressignificant advantages for refrigeration and air conditioningspecialists.

TM

Simplified installation process and reduction ofinstallation time.Reduction of overall network installation cost.Reliable operation of installations and significantenergy savings.Competively purchase price.Stylish and space saving.30-year guarantee, covering the quality of manifactureof the copper tube.

ACR TALOS ECUTHERM 2 pre-insulated copper tubes, havebeen certified by the German quality assurance organisationRWTUV, with regard to trials and manufacturing tests.The quality and reliability of such products, is ensured throughthe implementation of a Quality Assurance System, accordingto standard ISO 9001: 2000, certified by BUREAU VERITAS.

TM

Pair combinations for any application

Certified quality

Clear advantage in refrigeration and air conditioning

Page 18: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

MATERIAL PEF ÑÅ

30-31 Kg/m3

0,039 W/m.K

�12.000

-35 C to +95 Cο ο

CL1, DIN 4102 B2

Very good

60%

ÑÅ-×

DIN 4102 B2, BS 476, M1

30-33 Kg/m3

0,035 W/m.K

-80 C to +110 Cο ο

Very good

�12.000

60%

DENSITY ACCORDING TO DIN 53420ASTM D 1667

THERMAL CONDUCTIVITY COEFFICIENT (λ)ACCORDING TO ASTM C 335

VAPOUR-WATER DIFFUSSION RESISTANCECOEFFICIENT (μ) ACCORDING TO DIN 52615

WORKING TEMPERATURE

FIRE RESISTANCE

RESISTANCE TO CHEMICAL AGENTSACCORDING TO ASTM 543-56 T

SOUND ABSORPTION ACCORDING TODIN 4109 300-2500Hz

According to the new Uniform European Standard EN 12735-1, as well as current marketrequirements, laid down by the use of new green refrigerants, including R 410-A, alreadyadopted by all major manufacturers of refrigeration and air conditioning units, both inGreece and abroad, the following standardisation is applied to ACR TALOS ECUTHERM 2copper tubes:

For an external diameter of 1/4" to 1/2", the wall thickness is standardised at 0.80 mm.For an external diameter of 5/8" to 3/4", the wall thickness is standardised at 1.00 mm.

••

186 - 63

18,3 - 32,7

0,80-0,80

1/4 - 1/2

6,35-12,7

186 - 62

18,3 - 35,9

0,80-1,00

1/4 - 5/8

6,35-15,88

29,5 - 35,9

84 - 62

0,80-1,00

3/8 - 5/8

9,52-15,88

29,5 - 39,0

84 - 51

0,80-1,00

3/8 - 3/4

9,52-19,05

22,7 - 39,0

63 - 51

0,80-1,00

1/2 - 3/4

12,7-19,05

1/4 - 3/4

6,35 - 19,05

0,80 - 1,00

186 - 51

26,3 - 39,00 29,5 - 32,7

0,80-0,80

3/8 - 1/2

9,52-12,7

84 - 63

1/4 - 3/8

6,35-9,52

0,80-0,80

26,3 - 29,5

186 - 84

Copper tubewall thickness

Overall external diameterwith 9mm thick insulation

Maximum permitted workingpressure according to

ASTM B280

Copper tubeexternal diameter

inch

mm

mm

mm

bar

MECHANICAL PROPERTIES

Soft R-220 >220 >40

Temper ΕLΟΤ ΕΝ 1057Classification

TensileΝ/mm

strength2

Minimum elongationΑ5%

Values are listed as obtained under standard laboratory conditions and may be amendedwithout prior notice.

INSULATION TECHNICAL PROPERTIES

COPPER TUBE MATERIAL

Copper phosphorus deoxidised (DHP-Cu), minimum 99.9% Cu and P=0.015% - 0.040%.

Appropriate also for the new green refrigeration units

STANDARD PAIR DIMENSIONS (COILS 15m, 25m, 30m LONG)

Other sizes and special packaging in pallets or cardboard boxes are available upon request.

18

Page 19: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES
Page 20: ACR - tepse · All ACR TALOS copper tubes meet PED 97/23 requirements and the strict German regulation AD 2000/W6 on pressure tanks. ® QUALITY MARKS AENOR, TUV. MECHANICAL PROPERTIES

FA

LC

ON

P.0

9/0

60

01

/20

0.2

0/1

11

1

4 Dimitar Peshev str., Gara Iskar, 1528 Sofia, BULGARIATel.: +359 2 960 6350, +359 2 978 5209, Fax: +359 2 978 3393

[email protected]

Suite 4, Cobb House, 2-4 Oyster Lane, Byfleet, Surrey KT14 7DU, UNITED KINGDOMTel.: + 44 1932 33 11 11, Fax: + 44 1932 33 11 90

19, Rue de Passy, 750 16 Paris, FRANCETel. : + 33 1 4527 0754, Fax : + 33 1 4527 0708

[email protected]

Ursulastr. 33-41, D-50354 Hûrth GERMANYTel: +49 2233-7903 0, Fax +49 2233-7903 39

[email protected] - www.metallkc.de

V.Le Colleoni 1-PaL. Taurus20041 Agrate - Brianza (Mi), ITALY

Tel: +39 (039) 6420111, Fax: +39 (039) 6420150

119 Probuda street, Ilientzi, 1220 Sofia, BULGARIATel.: + 359 2 921 9111, Fax: + 359 2 931 1239

[email protected]

42 Drumul intre Tarlale street, 3rd sector, 73644 Bucharest, ROMANIATel.: + 40 21 209 0570, Fax: + 40 21 256 1464

[email protected]

Bul. Mihajla Pupina, br. 10a, objekat G, ulaz IV, YBC Kompleks-blok 1211070 Novi Beograd, SERBIA

Tel: + 38 III 3015876-7, Fax: +38 III [email protected]

e-mail:

METAL AGENCIES LIMITED

http://www.metalagencies.com

GENECOS S.A.

e-mail:

MKCMetall KundenCenter GmbH

e-mail: http://

ALURAME Srl

STEELMET S.A.

e-mail:

STEELMET ROMANIA S.A.

e-mail:

METAL GLOBE D.o.o.

e-mail:

A SUBSIDIARY OF HALCOR S.A.

57 km Athens-Lamia National Road, GR-320 11, Inofita-Viotia, GREECETel.: +30 22620 48 111, Fax: +30 22620 48 644

e-mail: [email protected] - http://www.halcor.gr

th