  • Mentor Graphics Confidential 1 January 2014

    AppNote MG580225

    A Practical On-Chip Clock Controller Circuit Design

    & Example Tessent ATPG Test Case

    January 2014

    Copyright Mentor Graphics Corporation 1995-2014. All rights reserved.

    This document contains information that is proprietary to Mentor Graphics Corporation. The original recipient of this document may duplicate this document in whole or in part for internal business purposes only, provided that this entire notice appears in all copies in duplicating any part of this document, the recipient agrees to make every reasonable effort to prevent the unauthorized use and distribution of the proprietary information.

    Trademarks that appear in Mentor Graphics product publications that are not owned by Mentor Graphics are trademarks of their respective owners.

  • Mentor Graphics Confidential 2 January 2014

    Table of Contents

    1. Introduction ............................................................................................................................................... 3

    2. On-Chip Clock Controller (OCC) Design Description ............................................................................... 3

    2.1. Design Placement............................................................................................................................ 3

    2.2. Schematic ........................................................................................................................................ 4

    2.3. Scan Enable Synchronization .......................................................................................................... 5

    2.4. Clock Gater Cells ............................................................................................................................. 5

    2.5. Internal Clock Definition for ATPG ................................................................................................... 5

    2.6. Shift Register Block ......................................................................................................................... 6

    2.7. Clock Control Operation Modes ....................................................................................................... 7

    2.7.1. Functional Mode ........................................................................................................................................... 7

    2.7.2. Shift Mode .................................................................................................................................................... 7

    2.7.3. Slow Capture Mode ...................................................................................................................................... 8

    2.7.4. Fast Capture Mode....................................................................................................................................... 8

    2.8. Timing Diagrams.............................................................................................................................. 8

    2.9. RTL Description ............................................................................................................................... 10

    Synthesized Gate Area ........................................................................................................................................ 11

    3. Test Case Description .............................................................................................................................. 12

    3.1. Test Case Design Statistics ............................................................................................................. 12

    3.2. Directory Structure ........................................................................................................................... 12

    3.3. Test Case Steps .............................................................................................................................. 13

    3.4. OCC RTL Simulation and Synthesis ................................................................................................ 13

    Simulation ............................................................................................................................................................ 13

    RTL Synthesis ...................................................................................................................................................... 14

    3.5. Step 1: View OCC Muxes ................................................................................................................ 14

    3.6. Step 2: Insert Clock Control Logic ................................................................................................... 15

    3.7. Step 3: Uncompressed Pattern Generation ..................................................................................... 17

    3.8. Step 4: Pattern Verification .............................................................................................................. 20

    3.9. Steps 5 to 8: Compression Logic Insertion, ATPG, and Verification ................................................ 21

  • Mentor Graphics Confidential 3 January 2014

    1. Introduction

    In modern designs, on-chip clock control (OCC) circuits are commonly used to manage clocks during test to ensure the following requirements are met:

    Independent control by ATPG of each clock domain to improve coverage, reduce pattern count, and achieve safe clocking with minimal user intervention

    During capture, deliver correct number of clock pulses on a per-pattern basis

    Cleanly switch between shift and capture clocks

    Enable slow or fast clocks during capture for application of slow and at-speed patterns

    Scan-programmable clock waveforms generated within a wrapped core are ideal for generating patterns at the core level that can be retargeted to the top level while simultaneously testing multiple cores without conflicts in how clocks are controlled within each core

    This application note describes a practical on-chip clock control circuit design and demonstrates its use in a test case using Tessent ATPG tools.

    If the target EDT hardware uses the Low Pin Count Test (LPCT) controller, contact Mentor Customer Support for information on how to use a modified OCC design with the LPCT EDT hardware.

    A complete test case that demonstrates the use of this OCC design in a circuit is described in the last section. The test case is available from Mentor Graphics by downloading it from the following SupportNet page: http://supportnet.mentor.com/reference/tutorials/index.cfm?id=MG576857

    2. On-Chip Clock Controller (OCC) Design Description

    2.1. Design Placement

    In order to avoid delay on the clock path due to test logic, a multiplexer should already exist on the clock source to the core flops and timed for functional behavior. The mux should be controlled by the test mode signal as shown in Figure 1 where existing logic is shown in gray.

    Figure 1 Clock Control Logic Design Placement

    It is important to only balance the functional clock path of the mux in order to avoid over-constraining the clock tree synthesis flow and causing excessive clock latency. For example, if using a layout tool like

    ICCompiler, this can be accomplished by using a set_clock_tree_exceptions -exclude_pins command and listing slow and fast clock inputs of the clock control block. In tools such as Talus from Magma, a skew group definition for each clock control block can be used.

    The clock control design described in this application note should supply the clock when in test mode while using the clock output of the PLL as the fast clock for at-speed capture. A top-level slow clock will be used for shift and slow capture. The reference clock supplied to the PLL is a free-running clock.

    It is also recommended not to flatten the clock control blocks during layout in order to ease definition of the test procedure file after layout.

  • Mentor Graphics Confidential 4 January 2014

    2.2. Schematic

    The schematic for the clock control circuit is shown in Figure 2 and the corresponding RTL can be found in section 2.9 of this document.

    Figure 2 On-Chip Clock Controller Logic Schematic

    The following table describes the functionality of pins at the top of the clock control block as well as some of the internal signals:

    Name Direction Description

    SCAN_EN Input Scan enable driven by top-level pin

    CAP_CYCLE_CONFIG [1:0] Input Configures number of clock pulses during capture cycle (maximum clock pulses = CAP_CYCLE_CONFIG + 1) as well as length of scan chain during shift

    SCAN_IN Input Scan chain input for loading shift register

    FAST_CAP_MODE Input Selects fast or slow capture clock (0 = slow, 1 = fast)

    TEST_MODE Input Selects test or functional mode (0 = functional, 1 = test). During functional mode, the clock control block is disabled to minimize power and cross talk.

    FAST_CLK Input Clock for fast capture (typically output of PLL)

    SLOW_CLK Input Clock for shift and slow capture

    SCAN_OUT Output Scan chain output for unloading shift register

    CLK_OUT Output Controlled clock output

    SCAN_EN_sync Internal Synchronized scan enable

    SHIFT_REG_CLK_en Internal Clock enable signal for shift register

    SHIFT_REG_CLK Internal Clock source for shift register

    CLK_OUT_source Internal Clock source for controlled clock output

    CLK_OUT_en Internal Clock enable signal for controlled clock output

    Static signals that do not change during the test session can be controlled through on-chip controllers (such as JTAG) or other means in order to reduce the need for top-level pins.

  • Mentor Graphics Confidential 5 January 2014

    2.3. Scan Enable Synchronization

    In order to synchronize the top-level scan enable signal with the fast clock (PLL output), a two-flop synchronization cell is used and clocked by FAST_CLK. This is important because scan enable is used as the trigger signal to gate the clock to the shift register. The output of the synchronization cell produces a scan enable signal which is synchronized with the fast clock (SCAN_EN_sync) and can be used during fast capture test.

    In version 1.1 of the clock controller RTL, a flop was added on the input side of the synchronization cell and clocked by the trailing edge of SLOW_CLK. Since SCAN_EN normally fans out to the entire circuit and may arrive after FAST_CLK, the flop on SLOW_CLK ensures that SCAN_EN is not synchronized by the fast clock until SLOW_CLK is pulsed thus reducing the risk of a race condition.

    Note that the scan enable synchronization logic is not used for slow capture mode which uses SLOW_CLK for shift and capture.

    In the RTL description, the synchronization cell is described as module tessent_sync_cell so that it can be replaced with a technology specific synchronization cell from the appropriate library.

    module tessent_sync_cell (d, clk, q);

    input d, clk;

    output q;

    reg [1:0] R;

    always @ (posedge clk) begin

    R

  • Mentor Graphics Confidential 6 January 2014

    This provides the same behavior as defining the internal clock on the output of the clock gating cell (cgc) but the mux can be easily identified by the setup script and eliminates any issues if a technology specific clock gating cell is used.

    With this specification, the slow shift clock is supplied to the design anytime SCAN_EN is high and should be pulsed in the shift procedures. The capture clock will be controlled by a clock control definition that describes the effects of the shift registers condition bits on each capture cycle.

    2.6. Shift Register Block

    Figure 3 Shift Register Block Schematic

    The shift register block contains the programmable scan cells which will be loaded during shift in order to pulse the internal clock during the cycle required by ATPG.

    The AND gate on the input of the shift register loads zeros into the register during capture to clear it. The EN output signal of the shift register block is used in the clock control block (Figure 2) to turn off the fast clock to the shift register once the shift register has been unloaded. This ensures switching from the fast capture clock to slow shift clock without risk of glitches and disturbing the values present in the shift register. It also ensures that the shift register flip-flops have stable values when the ATPG tool simulates the load_unload procedure and eliminates unnecessary DRC violations.

    A lockup cell on the SCAN_OUT output of the shift register block ensures proper shift operation when several clock control blocks are concatenated into a scan chain or when scan cells from chains with different clocks are combined with the shift register flops. This is important because as described in section 2.1, each clock control block forms a locally balanced clock tree which is not balanced with any other chain segment.

    A key feature of the shift register block is the ability to bypass up to 3 shift registers in order to reduce the number of bits that must be specified in the patterns. This is done by setting the CAP_CYCLE_CONFIG signals per the following table:

    CAP_CYCLE_CONFIG[1] CAP_CYCLE_CONFIG[0] Maximum Clock Pulses During Capture Cycle

    0 0 1

    0 1 2

    1 0 3

    1 1 4

  • Mentor Graphics Confidential 7 January 2014

    Limiting the number of condition bits to only those needed for the longest capture sequence reduces the overall shift cycles as well as the number of scan bits that must be specified for each pattern. Minimizing the number of specified scan cells per pattern will ensure the ATPG tool can provide the most efficient pattern set as well as the highest compression ratio when using embedded compression.

    In addition to limiting the overall number of specified scan cells, it is also important to limit the number of scan cells that must be specified in each shift cycle. When using compression, the output of the decompressor loads all chains simultaneously one shift cycle at a time. When stitching the shift register sub-chains into the design scan chains, care should be taken to avoid the alignment of multiple condition bits into the same shift cycle. One approach is to stitch the condition registers into an uncompressed scan chain which is directly loaded. For designs in which all scan chains are compressed, placing condition bits at the beginning, end or similar cell number of all scan chains should be avoided so that it is not necessary to load many specified bits in the same shift cycle.

    2.7. Clock Control Operation Modes

    2.7.1. Functional Mode

    When operating in functional mode (TEST_MODE = 0), all clock gaters are disabled to reduce power.

    Figure 4 Test Mode Disabled

    2.7.2. Shift Mode

    In shift mode (SCAN_EN = 1), SLOW_CLOCK is used to load/unload scan chains which include the condition bits in ShiftReg.

    Figure 5 Shift Mode Operation

  • Mentor Graphics Confidential 8 January 2014

    2.7.3. Slow Capture Mode

    In slow capture mode (FAST_CAP_MODE = 0), SLOW_CLOCK is used to capture data into scan cells and to shift the condition bits in ShiftReg.

    Figure 6 Slow Capture Mode Operation

    2.7.4. Fast Capture Mode

    In fast capture mode (FAST_CAP_MODE = 1), FAST_CLOCK is used to capture data into scan cells and to shift the condition bits in ShiftReg.

    Figure 7 Fast Capture Mode Operation

    2.8. Timing Diagrams

    The timing diagram for slow speed capture (FAST_CAP_MODE = 0) is shown in Figure 8. For this example, CAP_CYCLE_CONFIG is set to 10 resulting in sequential depth of 3 (per table in section 2.6). In this mode, SLOW_CLK is used for shift as well as capture. Based on condition bits loaded into the shift register, the CLK_OUT port will generate the appropriate number of slow clock pulses.

    Figure 8 Slow Speed Capture Timing Diagram

  • Mentor Graphics Confidential 9 January 2014

    In fast capture mode (FAST_CAP_MODE = 1) the waveforms in Figure 9 are generated. Similar to the previous example, CAP_CYCLE_CONFIG is set to 10 here resulting in sequential depth of 3. In this mode, the slow clock is still used for shift but the fast capture pulses on CLK_OUT are based FAST_CLK. As shown, the scan enable signal which has been synchronized to the fast clock (SCAN_EN_sync) is used to trigger the fast clock pulses on SHIFT_REG_CLK. The SHIFT_REG_CLK signal is the clock source for the shift register containing the condition bits. Based on the condition bits loaded during shift, the correct number of fast clock pulses will appear on CLK_OUT.

    Figure 9 Fast Capture Timing Diagram

  • Mentor Graphics Confidential 10 January 2014

    2.9. RTL Description

    The RTL description of the circuit described in this application note and used in the test case is shown in the following section:

    (* version=1.2 *)

    module tessent_atpg_clock_controller (FAST_CLK, SLOW_CLK, TEST_MODE, SCAN_IN, SCAN_EN,

    FAST_CAP_MODE, CAP_CYCLE_CONFIG, SCAN_OUT, CLK_OUT);

    input FAST_CLK, SLOW_CLK, TEST_MODE, SCAN_IN, SCAN_EN, FAST_CAP_MODE;

    input [1:0] CAP_CYCLE_CONFIG;

    output SCAN_OUT, CLK_OUT;

    wire SCAN_EN_sync;

    wire ShiftReg_EN;

    wire ShiftReg_SCAN_OUT;

    wire SHIFT_REG_CLK_en;

    wire SHIFT_REG_CLK_G;

    wire SHIFT_REG_CLK;

    wire CLK_OUT_source;

    wire CLK_OUT_en;

    wire CLK_OUT_G;

    reg ShiftReg_SCAN_OUT_lockup;

    reg SE_SLOW_CLK;

    always @ (negedge SLOW_CLK) begin

    SE_SLOW_CLK

  • Mentor Graphics Confidential 11 January 2014

    module tessent_sync_cell (d, clk, q);

    input d, clk;

    output q;

    reg [1:0] R;

    always @ (posedge clk) begin

    R

  • Mentor Graphics Confidential 12 January 2014

    3. Test Case Description

    In the test case that accompanies this application note, Tessent Shell is used for pattern generation, EDT IP creation and hardware insertion. A test case which implements the clock controller design in this application note has been verified with tool version v2013.4 and is available from Mentor Graphics (see section 1 for download link). The following section describes the test case in more detail.

    3.1. Test Case Design Statistics

    The example design used in this test case has the following characteristics:

    Gates: 10k Clocks: 3 internal clocks Scan chains: 12

    o 11 design chains o 1 clock control condition bits (load only)

    Scan flops: 446 Total faults: 48k Test Coverage:

    o Stuck-at: ~99% o Transition: ~93%

    3.2. Directory Structure

    The test case directory contains the following directories

    /design o /edt_created

    Verilog, dofiles, and procedure files generated during EDT IP creation o /gates

    Gate-level netlist Synthesized clock controller

    o /rtl

    /clock_controller

    Clock controller RTL

    Simulation test benches and scripts

    Synthesis script /pll

    Simple RTL simulation model /dofiles

    o Command dofile o Test procedure file

    /library o /liberty

    Liberty file o /synopsys

    Compiled synthesis library file t18.db is not shipped with this test case due to licensing agreements but should be placed in this directory for use by various

    synthesis steps. The t18.db file can be created from the supplied liberty file

    (t18.lib) using Synopsys lc_shell library compiler.

    o /tessent

    Tessent cell library o /verilog

    Simulation library /logfiles

    o Generated log files

  • Mentor Graphics Confidential 13 January 2014

    /patterns

    o Generated pattern files /scripts

    o TCL scripts for OCC insertion and control

    3.3. Test Case Steps

    Step 1 o View OCC muxes in design

    Step 2 o Insert clock control logic

    Steps 3 4 o Create and simulate uncompressed patterns with internal clocks (slow and fast

    capture)

    Steps 5 6 o Create, insert, and synthesize EDT hardware

    Steps 7 8 o Create and simulate compressed patterns with internal clocks (slow and fast capture)

    3.4. OCC RTL Simulation and Synthesis

    Before running the test case steps in section 3.3, you may want to examine the OCC RTL in the design/rtl/clock_controller directory and run the simulations. You will likely also need to synthesize

    the RTL with your technology-specific library. These steps are explained in this section.

    Simulation

    Before synthesizing the clock controller RTL, it can be simulated to ensure clock pulses are generated as expected. To run the simulation, execute the following scripts in the design/rtl/clock_controller

    directory.

    run_vsim_slow_capture

    run_vsim_fast_capture

    For slow capture test, the test bench in the referenced directory sets the CAP_CYCLE_CONFIG signals to 01 and loads the condition bits to generate a single clock pulse during capture. The waveform for slow capture test is shown in Figure 10.

    Figure 10 RTL Simulation Results for Slow Capture Test

  • Mentor Graphics Confidential 14 January 2014

    For the fast capture test example, the CAP_CYCLE_CONFIG value is set to 11 and condition bits are setup to create 2 fast clock pulses during capture on CLK_OUT in the second and third cycles. The waveform for fast capture test is shown in Figure 11.

    Figure 11 RTL Simulation Results for Fast Capture Test

    RTL Synthesis

    After verification, the RTL is synthesized using a Design Compiler synthesis script in the design/rtl/clock_controller directory:

    run_synthesis

    This script will run a simple synthesis based on the supplied ADK library and can be used as a template for synthesizing the RTL with your technology-specific library. The synthesis script will create the following gate-level netlist:

    design/gates/tessent_occ.vg

    NOTE: The compiled synthesis library file t18.db is not shipped with this test case due to licensing

    agreements but should be placed in the library/synopsys directory for use by various synthesis

    steps. The t18.db file can be created from the supplied liberty file (t18.lib) using Synopsys lc_shell library compiler.

    3.5. Step 1: View OCC Muxes

    Before inserting the clock controller into the design, you can view the muxes that already exist on the output of the PLL. Typically these muxes would be inserted and balanced as described in section 2.1. To view the PLL and clock muxes in DFTVisualizer, execute the following script:

    1.display_occ_muxes

    The tool will display the PLL and 3 clock muxes in DFTVisualizers Design window as seen in Figure 12. As shown, the test_mode signal selects the the functional test path to allow the PLL clock to drive design

    logic.

    The A1 input of each mux is left floating so that the output of the OCC can be connected and selected when test_mode is set to 1. The OCC insertion script will connect to each OCC mux and supply the slow

    and fast clock for test through these muxes which have already been timed and balanced.

  • Mentor Graphics Confidential 15 January 2014

    Figure 12 Existing PLL and OCC muxes

    3.6. Step 2: Insert Clock Control Logic

    The next step is to run Tessent Shell and insert an instance of the clock control logic for each internal clock. Execute the following script to insert the clock control logic:

    2.insert_clock_control

    See the insertion dofile for details of various commands in Tessent Shell for insertion and design editing.

    #! /bin/sh -f

    #\

    exec tessent -shell -log logfiles/$0.log -replace -dofile "$0"

    ###################################################################

    ## SCRIPT TO INSERT CLOCK CONTROLLER INTO THE DESIGN

    ## TESSENT VERSION 2013.4

    ###################################################################

    set_context dft -no_rtl

    read_verilog design/gates/cpu_scan_pll.vg

    read_verilog design/gates/tessent_occ.vg

    # Read cell library to allow creation of some instances such as muxes

    read_cell_library library/tessent/adk.tessent_cell

    Execute Tessent

    Shell and specify

    log file and

    dofile commands

    Read gate level

    design files and

    cell library

  • Mentor Graphics Confidential 16 January 2014

    set_current_design cpu

    set_system_mode insertion

    # Create collection of OCC mux input ports where OCCs should be created. For

    # each specified connection point, an OCC will be created and its CLK_OUT

    # will be connected to the specified connection point.

    set clock_connections [get_pins MUX_OCC*/A1]

    # Define scan-enable and PLL clock output port that should drive the fast port on clock

    controllers

    set pll_clock_port pll_i/pll_clock_180

    set scan_enable_port test_se

    set test_mode_port test_mode

    # Insert an OCC block for each clock connection point in $clock_connections

    dofile scripts/insert_occ.tcl

    insert_occ $scan_enable_port $clock_connections $pll_clock_port $test_mode_port

    write_design -output_file design/gates/cpu_scan_occ.vg -exclude_modules "pll" -replace

    exit -force

    The Tessent Shell insertion script calls the insert_occ procedure in the following TCL script

    (scripts/insert_occ.tcl) to perform OCC insertion and design edits:

    ###################################################################

    ## PROCEDURE TO INSERT TESSENT OCC INTO A DESIGN

    ## TESSENT VERSION 2013.4

    ###################################################################

    proc insert_occ {var_scan_enable clock_connections pll_clock_port var_test_mode} {

    # Define top -level port names to create

    set var_slow_clock slow_clock

    set var_cap_config cap_cycle_config

    set var_fast_cap_mode fast_capture_mode

    set var_scan_in occ_control_scan_in

    # Create top-level ports for new signals

    create_port $var_slow_clock -direction input

    create_port $var_cap_config[1:0] -direction input

    create_port $var_fast_cap_mode -direction input

    create_port $var_scan_in -direction input

    # Create instances of OCC for each clock in $clock_conntections and connect

    set num_clocks [sizeof_collection $clock_connections]

    for {set i 1} {$i

  • Mentor Graphics Confidential 17 January 2014

    ###################################################################

    ## Create dofile to setup design with OCC

    ###################################################################

    set var_scan_group_name grp1

    set file_dofile [open dofiles/occ_scan_setup.dofile w]

    puts $file_dofile "# Define slow clock created by this script. If it already exists and \

    connected to the OCC"

    puts $file_dofile "# outside of this script, this can be removed but it should be \

    defined during ATPG."

    puts $file_dofile "add_clocks 0 $var_slow_clock"

    puts $file_dofile ""

    puts $file_dofile "# Define clock control scan chain as load-only to reduce pins. \

    Should be uncompressed if"

    puts $file_dofile "# number of OCCs is high to reduce specified bits."

    puts $file_dofile "add_scan_chains -load_only clock_control_chain $var_scan_group_name \

    $var_scan_in $internal_scan_out"

    close $file_dofile

    }

    After OCC insertion, the modified design is saved and patterns can be generated using internal clocks.

    3.7. Step 3: Uncompressed Pattern Generation

    To run pattern generation, execute the following script at the top directory:

    3.create_patterns

    The script can be used to perform slow or fast clock capture and can also initialize the design using IJTAG/PDL or explicit input constraints. Invocation options described at top of the script determine which combination is used. If no arguments are specified, by default the script will initialize the design using IJTAG/PDL and create slow speed capture pattenrs. Contents of this and other included dofiles are shown here:

    #! /bin/sh -f

    #\

    exec tessent -shell -dofile "$0" -arg ${1+"$@"}

    # Script to create patterns. Invoke with -arguments to change default settings.

    # - To create at-speed patterns

    # 3.create_patterns -arguments atpg_mode=fast_capture

    # - To initialize using top-level input constraints

    # 3.create_patterns -arguments initialization=constraints

    # Define default values to user-specifiable parameters

    array set params {

    atpg_mode slow_capture

    initialization pdl

    }

    # Override defaults with user-specified command line options, if specified

    array set params $tessent_user_arg

    set atpg_mode $params(atpg_mode)

    set initialization $params(initialization)

    # Create log file

    set_logfile_handling logfiles/3.create_patterns_${atpg_mode}_${initialization}.log -replace

    if {$initialization == "pdl"} {

    set_context patterns -ijtag

    read_verilog design/gates/cpu_scan_occ.vg

    read_cell_library library/tessent/adk.tessent_cell

    read_icl design/gates/tessent_occ.icl

    add_black_box -module pll

    Read design netlist and ICL

    file to setup design for

    initialization with IJTAG/PDL

  • Mentor Graphics Confidential 18 January 2014

    report_module_matching -icl

    set_system_mode analysis

    set_system_mode setup

    set_context patterns -scan

    # Read the PDL file that defines necessary constrain values on boundary of OCC module

    source design/gates/tessent_occ.pdl

    # Apply the constrain values in PDL to all instances of the OCC

    if {$atpg_mode == "slow_capture"} {

    set fast_cap_mode_value 0

    } elseif {$atpg_mode == "fast_capture"} {

    set fast_cap_mode_value 1

    } else {

    error "Invalid command line argument '$atpg_mode' for 'atpg_mode '. Use '-arguments

    atpg_mode=' to specify. Valid values are 'slow_capture' and 'fast_capture'"

    }

    foreach occ_inst [get_name_list [get_icl_instances -of_module tessent_occ]] {

    set_test_setup_icall [list $occ_inst.setup fast_cap_mode $fast_cap_mode_value

    cap_cycle_config 4] -append

    }

    } elseif {$initialization == "constraints"} {

    # The above IJTAG commands automatically create the below 4 input constraints by tracing

    # these control signals from the boundary of each OCC instnace to the top of the design

    # and enforcing the values defined in the PDL file for each port. This eliminates the

    # need for you to map these signals and setting the input constraints manually. This

    # method also verifies that each OCC's control signsal is correctly connected to top.

    # Alternatively, you can use the following explicit commands to constrain the top level

    # ports assuming that you ensure the connections to all OCCs are correct.

    set_context patterns -scan

    read_verilog design/gates/cpu_scan_occ.vg

    read_cell_library library/tessent/adk.tessent_cell

    add_black_box -module pll

    add_input_constraints -c1 test_mode

    add_input_constraints -c1 cap_cycle_config[1]

    add_input_constraints -c1 cap_cycle_config[0]

    if {$atpg_mode == "slow_capture"} {

    add_input_constraints -c0 fast_capture_mode

    } elseif {$atpg_mode == "fast_capture"} {

    add_input_constraints -c1 fast_capture_mode

    } else {

    error "Invalid command line argument '$atpg_mode' for 'atpg_mode '. Use '-arguments

    atpg_mode=' to specify. Valid values are 'slow_capture' and 'fast_capture'"

    }

    } else {

    error "Invalid command line argument '$initialization' for 'initalization '. Use

    '-arguments initialization=' to specify. Valid values are 'pdl' and

    'constraints'"

    }

    add_input_constraints -c0 test_se

    # Using either method (IJTAG or explicit add_input_constraint commands) will result

    # in the following report in ANALYSIS mode:

    #ANALYSIS> report_input_constraints

    #// Primary Input C-Type Hold No-Z Slow-Pad

    #// ------------------- ------ ---- ---- --------

    #// rst_in C1 N/A No N/A

    #// test_se C0 No No N/A

    #// test_mode C1 No No N/A

    #// cap_cycle_config[1] C1 No No N/A

    #// cap_cycle_config[0] C1 No No N/A

    #// fast_capture_mode C0 No No N/A

    # Define scan chains

    add_scan_group grp1 dofiles/atpg.testproc

    dofile dofiles/scan_setup.dofile

    dofile dofiles/occ_scan_setup.dofile

    dofile dofiles/pll_setup.dofile

    Run DRC to find each instance

    of Tessent OCC and learn

    connectivity to top-level ports

  • Mentor Graphics Confidential 19 January 2014

    if {$atpg_mode == "fast_capture"} {

    set_fault_type transition -no_shift_launch

    set_output_masks on

    add_input_constraints -all -hold

    }

    # Define internal clocks for clock controller

    dofile scripts/tessent_occ.tcl

    tessent_occ_config $atpg_mode

    # Run Design Rule Checks

    set_system_mode analysis

    report_input_constraints

    tessent_occ_config $atpg_mode

    if {$atpg_mode == "fast_capture"} {

    set_external_capture_options -capture_procedure ext_fast_cap_proc

    }

    # Run ATPG

    create_patterns

    # Save pattern (SIM_KEEP_PATH includes full pattern file pathnames in test bench)

    report_patterns > patterns/patterns_report_$atpg_mode.txt

    write_patterns patterns/pat1_${atpg_mode}_parallel.v -verilog -parallel -parameter_list

    {SIM_KEEP_PATH 1} -replace

    set_pattern_filtering -sample 2

    write_patterns patterns/pat1_${atpg_mode}_serial.v -verilog -serial -parameter_list

    {SIM_KEEP_PATH 1} -replace

    exit

    Once patterns are generated, test benches are saved for simulation against Verilog. The SIM_KEEP_PATH parameter ensures that the full pathnames of pattern files are saved in the test bench

    so that it is not mandatory to run the simulation from the patterns directory.

    The test procedure file used for ATPG is common for all test modes and is stored in the file dofiles/atpg.testproc. The content of this file is shown below:

    //

    // Test Procedure File

    //

    timeplate tmp1 =

    force_pi 0 ;

    measure_po 2 ;

    pulse_clock 16 32;

    period 64 ;

    end;

    procedure test_setup =

    timeplate tmp1 ;

    cycle =

    force test_mode 1;

    pulse rst_in;

    pulse slow_clock;

    end;

    end;

    procedure shift =

    timeplate tmp1 ;

    cycle =

    force_sci ;

    measure_sco ;

    pulse slow_clock;

    pulse int_clk1;

    pulse int_clk2;

    pulse int_clk3;

    Script and procedure call to find

    all Tessent OCCs in design and

    automatically define internal

    clocks and setup for ATPG

    For at-speed test using fast clock

    capture, setup fault type, mask

    outputs, and constrain inputs

    Procedure call to configure design

    based on DRC results

    Timeplate globally defines force,

    measure, and pulse timing for all

    signals. Note the pulse_clock

    statement is new in 2013.4 release.

  • Mentor Graphics Confidential 20 January 2014

    end;

    end;

    procedure load_unload =

    scan_group grp1 ;

    timeplate tmp1 ;

    cycle =

    force test_se 1;

    end;

    apply shift 44;

    end;

    procedure external_capture ext_fast_cap_proc =

    timeplate tmp1 ;

    cycle =

    force_pi ;

    pulse slow_clock;

    end;

    end;

    Most of the test procedure file is typical to most scan design. Additionally, the test procedure file contains the external capture procedure ext_fast_cap_proc to ensure proper pulses on external clocks are saved to the pattern file when fast clock is used for capture.

    3.8. Step 4: Pattern Verification

    The next step is to simulate the generated patterns to ensure no mismatches exist. The following script simulates serial and paralel Verilog test benches in various test modes:

    4.simulate_patterns

    The script compiles the design, library, and patterns using ModelSim and verifes that all patterns (serial and parallel) simulate with no mismatches. The simulation waveform for slow capture pattern number 0 is shown in Figure 13:

    Figure 13 Pattern Simulation Results for Slow Capture Test

    The last 3 signals are the output of the clock control blocks which show a single pulse on the output of

    clock_control_i2/CLK_OUT. This matches the output of the report_patterns command which is stored

    in the file patterns/patterns_report_slow_capture.txt. The content of this file for the first few

    pattersn is shown here:

    //

    // pattern # type cycles loads ... capture_clock_sequence

    // --------- ------- ------ ----- ---------------------------------------------

    // 0 basic 1 1 [slow_clock,int_clk2,int_pll]

    // 1 basic 1 1 [slow_clock,int_clk2,int_pll]

    // 2 basic 1 1 [slow_clock,int_clk3,int_pll]

    // 3 basic 1 1 [slow_clock,int_clk2,int_pll]

    // 4 basic 1 1 [slow_clock,int_clk2,int_pll]

    // 5 basic 1 1 [slow_clock,int_clk2,int_pll]

    We can see that scan pattern number 0 pulses the top level slow_clock and internal clocks int_clk_2

    and int_pll. Note that the top level reference_clock which is a free-running clock is also pulsed in the

    The external_capture procedure is

    used for fast clock capture to

    ensure a pulse on slow_clock at the

    start of each pattern. See section

    2.8 and Figure 9 for an explanation

    of why this pulse is needed.

  • Mentor Graphics Confidential 21 January 2014

    test bench but because it is an asynchronous free-running clock it is not reported in the output of the report_patterns command.

    Similar observations can be made for fast capture pattern number 0 which pulses in_clk2 followed by

    int_clk2. The waveform for this pattern is shown in Figure 14:

    Figure 14 Pattern Simulation Results for Fast Capture Test

    The corresponding report_patterns output is shown below:

    //

    // pattern # type cycles loads ... capture_clock_sequence

    // --------- ------- ------ ----- --------------------------------------

    // 0 clock_sequential 2 1

    [int_clkg_3,int_clk2,int_clkg_2,int_clkg_1,int_pll]

    [int_clkg_3,int_clk2,int_clkg_2,int_clkg_1,int_pll]

    // 1 clock_sequential 2 1

    [int_clkg_3,int_clk2,int_clkg_2,int_clkg_1,int_pll]

    [int_clkg_3,int_clk2,int_clkg_2,int_clkg_1,int_pll]

    // 2 clock_sequential 2 1

    [int_clkg_3,int_clk2,int_clkg_2,int_clkg_1,int_pll]

    [int_clk3,int_clkg_3,int_clkg_2,int_clkg_1,int_pll]

    // 3 clock_sequential 2 1

    [int_clkg_3,int_clk2,int_clkg_2,int_clkg_1,int_pll]

    [int_clkg_3,int_clk2,int_clkg_2,int_clkg_1,int_pll]

    // 4 clock_sequential 2 1

    [int_clkg_3,int_clk2,int_clkg_2,int_clkg_1,int_pll]

    [int_clkg_3,int_clk2,int_clkg_2,int_clkg_1,int_pll]

    // 5 clock_sequential 2 1

    [int_clkg_3,int_clk2,int_clkg_2,int_clkg_1,int_pll]

    [int_clkg_3,int_clk2,int_clkg_2,int_clkg_1,int_pll]

    3.9. Steps 5 to 8: Compression Logic Insertion, ATPG, and Verification

    The next steps in the test case demonstrate the use of Tessent Shell to create and insert EDT compression logic [step 5] and to synthesize the created RTL with Design Compiler [step 6]:

    5.insert_edt_ip

    6.synthesize_edt_ip

    The IP creation step runs Tessent Shell with slow clock and fast clock setup files in order to automatically create the ATPG files for both clock speeds. Since only one compression hardware design file is needed, only the IP creation step with slow clock writes the compression hardware to a file. This file is synthesized in step 6.

    NOTE: The compiled synthesis library file t18.db is not shipped with this test case due to licensing

    agreements but should be placed in the library/synopsys directory for use by various synthesis

    steps. The t18.db file can be created from the supplied liberty file (t18.lib) using Synopsys lc_shell library compiler.

    The next step is to create compressed patterns using the slow and fast capture clocks [step 7]:

    7.create_edt_patterns

  • Mentor Graphics Confidential 22 January 2014

    7.create_edt_patterns atpg_mode=fast_capture

    Similar to the 3.create_patterns script, the default behavior of the pattern generation script is to use the ICL and PDL descriptions of the OCC to constrain the inputs of each OCC. This simplifies the flow by automatically finding all OCCs in the design and ensuring that their control inputs defined in the PDL are properly constrainted. An alternative method is to use explicit input constraints in the dofile but this requires the user to ensure the OCCs are connected to the top and works for directly connected pins but may be more complicated in other cases. The ICL/PDL method is a more general solution which also handles hardware that is initialized through IJTAG or TAP controllers.

    In order to use input constraints in the pattern generation script, the initialization=constraints argument can be used at command line. For example:

    7.create_edt_patterns initialization=constraints

    7.create_edt_patterns initialization=constraints atpg_mode=fast_capture

    The final step is to simulate the compressed patterns to ensure no mismatches exist. Script 8 simulates all compressed patterns:

    8.simulate_edt_patterns

    To run all steps in the test case, you can use the 0.run_all_steps script but as stated earlier, the synthesis library is not part of the test case and will require proper setup for running step 5 to synthesize the EDT hardware.

    To obtain the complete test case for the flow described in this application note, use the download link in section 1 of this document.

    If the target EDT hardware uses the Low Pin Count Test (LPCT) controller, contact Mentor Customer Support for information on how to use a modified OCC design with the LPCT EDT hardware.